ADOPTS WITH AMENDMENTS:

International Building Code 2009 (IBC 2009)

Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard.
Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to these standards in accordance with Section 28-103.19 of the Administrative Code.
The application of the referenced standards shall be as specified in Section 102.4.
AA Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
Standard
reference
number
Title Referenced
in code
section number
ADM—00 Specifications & Guidelines for Aluminum Structures 1704.28.1, 2002.1
ADM 1—05 Aluminum Design Manual: Part 1-A Specification for Aluminum Structures, Allowable Stress Design;
and Part 1-B-Aluminum Structures, Load and Resistance Factor Design
1604.3.5
ASM 35—00 Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1

AAMA American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 104
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
1402—86 Standard Specifications for Aluminum Siding, Soffit and Fascia 1404.5.1
AAMA/WDMA/CSA
101/I.S.2/A440—08
North American Fenestration Standard/Specifications for Windows, Doors, and Skylights 1715.5.1, 2405.5

AASHTO American Association of State Highway and Transportation Officials
444 N Capitol Street NW, Suite 249
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
T318—07 Standard Method of Test for Water Content of Freshly Mixed Concrete
Using Microwave Oven Drying
1905.6.2.1, 1905.6.3.6

ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
216.1—07 Standard Method for Determining Fire Resistance of Concrete and
Masonry Construction Assemblies
Table 720.1(2), 721.1
301—05 Specification for Structural Concrete 1905.2.4, 1905.6.3.7
306—90 Standard Specification for Cold Weather Concreting—Reapproved 2002 Table 1904.4.2
318—11 Building Code Requirements for Structural Concrete 406.5.4, 721.2.4.3, 1604.3.2,Table 1613.8, Table 1704.3, 1704.3.1.3, Table 1704.4, 1704.4.1 Table 1704.32, 1805.5.7.2, 1805.9, Table 1808.2.13, 1808.9.2.1, 1808.9.3, 1808.9.3.1, 1809.6.3.2, 1809.6.3.2.2,1810.1.2.5.1, 1810.1.2.5.2, 1810.7.4.1, 1810.8.3, 1810.8.4, 1901.2, 1901.3, 1901.4, 1902.1, 1903.1, 1903.2, 1903.3, 1903.4, 1903.5, 1903.5.1, 1903.5.2, 1903.6, 1903.7, 1904.1, 1904.2, 1904.3, 1904.4.1, 1904.5, 1905.1.1, 1905.1.4, 1905.3, 1905.4, 1905.5, 1905.6.5.5, 1905.6.6, 1905.8.3, 1905.11.3,1906.1, 1906.2, 1906.3, 1906.4, 1907.1, 1907.2, 1907.4.1, 1907.6, 1907.7.2, 1907.7.3, 1907.7.4, 1907.7.5, 1907.7.6, 1907.8, 1907.9, 1907.10, 1907.11, 1907.12, 1907.13, 1908, 1908.1, 1908.1.1, 1908.1.2, 1908.1.3, 1908.1.4, 1908.1.5, 1908.1.6, 1908.1.7, 1908.1.8, 1908.1.9, 1908.1.11, 1908.2, 1908.2.1, 1909.1, 1909.3, 1909.4, 1909.5, 1909.6, 1912.1, 1912.1.1, 1915.2, 1915.3, 1915.4, 1915.6, 1916.2, 1916.3.1, 2108.3, 2205.3, 3305.3.2
530—08 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, 1704.5.1, Table 1704.5.1, 1704.5.2, Table 1704.5.3, 1704.5.3, 2101.2.2, 2101.2.3, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2103.8, 2104.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2110.1
530.1—08 Specifications for Masonry Structures 1404.3.1, Table 1704.5.1, Table 1704.5.3, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.3, 2104.4, 2104.6, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3, 2105.4

AF&PA American Forest & Paper Association
1111 19th St, NW Suite 800
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
WCD No. 4—89 Wood Construction Data-Plank and Beam Framing for Residential Buildings 2306.1.2
WFCM—01 Wood Frame Construction Manual for One-and Two-family Dwellings 1609.1.1, 1609.1.1.1, 2301.2, 2308.1, 2308.2.1
TR7—07 Basic Requirements for Permanent Wood Foundation System, Technical Report No. 7 1807.2
NDS—05 National Design Specification (NDS) for Wood Construction with 2005 Supplement 721.1, 721.6.3.2, 1716.1.1, 1716.1.4, 1809.5, 1908.1.9, 2302.1, 2304.12, 2306.1, Table 2306.2.1(1), Table 2306.2.1(2), Table 2306.3, Table 2306.6, 2307.1, 2307.1.1
AF&PA—93 Span Tables for Joists and Rafters 2306.1.1, 2308.8, 2308.10.2, 2308.10.3
AF&PA PWF—07 Permanent Wood Foundation Design Specification 2304.9.5.2
AF&PA SDPWS—08 Special Design Provisions for Wind and Seismic 2302.1, 2305.1, 2306.1, 2306.2.1, 2306.2.2, 2306.2.3, 2306.3, Table 2306.3, 2306.4, 2306.5,2306.6, 2306.7, 2307.1, 2307.1.1

AHA American Hardwood Association
1210 West N.W. Highway
Palatine, IL 60067
Standard
reference
number
Title Referenced
in code
section number
A135.4—95 Basic Hardboard 1404.3.1
A135.6—98 Hardboard Siding 1405.3.2

AISC American Institute of Steel Construction
One East Wacker Drive, Suite 700
Chicago, IL 60601-18021
Standard
reference
number
Title Referenced
in code
section number
341—05 Seismic Provisions for Structural Steel Buildings, including Supplement No 1. Dated 2005 1613.6.1, 2205.2.1, 2205.2.2, 2205.3, 2205.3.1
360—05 Specification for Structural Steel Buildings 721.5.2.2.1,1604.3.3, 1704.3.3, Table 1704.3,1915.2, 1915.3, 1915.4, 1915.6, 2203.1, 2203.2, 2205.1, 2205.1.1, 2205.3, 2205.6, 2205.6.2, 2205.6.3, 2212.2, 3305.2

AISI American Institute of Steel Construction
25 Massachusetts Avenue, NW
Suite 100
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
S100—07 North American Specification for the Design of Cold-formed
Steel Structural Members
1604.3.3,1908.1.9, 2203.1, 2209.1, 2210.2, 2210.4, 2210.5
S200—07 North American Standard for Cold-formed Steel Framing—General Provisions Table 1704.3.4, 2203.1, 2203.2
S211—07 North American Standard for Cole-formed Steel Framing—Wall Stud Design 2210.4
S212—07 North American Standard for Cold-formed Steel Framing—Header Design 2210.2
S213—07 North American Standard for Cold-formed Steel Framing—Lateral Design 2210.6
S214—07 North American Standard For Cold-formed Steel Framing—Truss Design,
with Supplement 2, dated 2008
2210.3.1, 2210.3.2
S230—07 Standard for Cold-formed Steel Framing—Prescriptive Method for
One- and Two-family Dwellings, with Supplement 2, dated 2008
1609.1.1, 1609.1.1.1,2210.7
Seismic Provisions for Structural Steel Buildings, including
Supplement No. 1 dated 2005
1613.6.1, 2205.2.1, 2205.2.2, 2205.3, 2205.3.1
S110—07 Standard for Seismic Design of Cold-formed Steel Structural Systems—Special Bolted Table 1613.8
S210—07 North American Standard for Cold-formed Steel Framing—Floor and Roof System Design 2210.5

AITC American Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood, CO 80112
Standard
reference
number
Title Referenced
in code
section number
AITC Technical
Note 7—96
Calculation of Fire Resistance of Glued Laminated Timbers 721.6.3.3
AITC 104—03 Typical Construction Details 2306.1
AITC 110—01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1
AITC 113—01 Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117—04 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1
AITC 119—96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1
AITC 200—04 Structural Glued Laminated Timber 2306.1
ANSI/AITC A 190.1—07 Structural Glued Laminated Timber 2303.1.3, 2306.1

ALI Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045
Standard
reference
number
Title Referenced
in code
section number
ALI ALCTV—2006 Standard for Automobile Lifts —Safety Requirements for Construction, Testing and Validation (ANSI) 3001.2

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A10.3—06 Safety Requirements for Powder-actuated Fastening Systems 3311.3, 3311.4, 3311.4.1, 3311.4.2, 3311.4.3, 3311.4.4, 3311.4.5, 3311.4.6, 3311.4.7, 3311.4.8, 3311.4.9, 3311.4.10, 3311.4.11, 3311.4.12
A10.4—07 Safety Requirements for Personnel Hoists 3010.3
A10.11—10 Safety Requirements for Personnel and Debris Nets 3302.1, 3308.6.2, 3308.6.2.3, 3308.6.2.4, 3308.6.2.5, 3308.6.2.6, 3308.6.2.7, 3308.6.2.8, 3308.6.2.9, 3308.6.2.10, 3308.6.2.11, 3308.6.4
A 13.1—96
(Reaffirmed 2002)
Scheme for the Identification of Piping Systems 415.8.6.4, 903.6, 905.11
A108.1A—99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.10
A108.1B—99 Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting
Bed with Dry-set or Latex-Portland Mortar
2103.10
A108.4—99 Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive 2103.10.6
A108.5—99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-portland Cement Mortar 2103.10.1, 2103.10.2
A108.6—99 Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting-and-grouting Epoxy 2103.10.3
A108.8—99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.10.4
A108.9—99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.10.5
A108.10—99 Installation of Grout in Tilework 2103.10.7
A118.1—99 American National Standard Specifications for Dry-set Portland Cement Mortar 2103.10.1
A118.3—99 American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and
-grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive
2103.10.3
A118.4—99 American National Standard Specifications for Latex-Portland Cement Mortar 2103.10.2
A118.5—99 American National Standard Specifications for Chemical-resistant Furan Mortar and Grouts for Tile Installation 2103.10.4
A118.6—99 American National Standard Specifications for Cement Grouts for Tile Installation 2103.10.7
A118.8—99 American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout 2103.10.5
A136.1—99 American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile 2103.10.6
A137.1—88 American National Standard Specifications for Ceramic Tile 2103.5
A208.1—99 Particleboard 2303.1.7, 2303.1.7.1
Z97.1—04 Safety Glazing Materials Used in Buildings-Safety Performance Specifications and Methods of Test 2406.1.2, 2406.2, 2406.3.1, Table 2406.2(2), 2407.1.4.1, 2408.1, 2408.2.1, 2408.3, 2409.2, 2409.3.1
Z535.1—06 Safety Colors 1024.2.6.2, 1024.3.1, 1024.6.1
Z535.2—07 Environmental and Facility Safety Signs K1-6.1.6.9.2

APA APA - Engineered Wood Association
7011 South 19th Street
Tacoma, WA 98466-5333
Standard
reference
number
Title Referenced
in code
section number
APA PDS—04 Panel Design Specifications 2306.1
APA PDS
Supplement 1—90
Design and Fabrication of Plywood Curved Panels (revised 1995) 2306.1
APA PDS
Supplement 2—92.
Design and Fabrication of Plywood-lumber beams (revised 1998) 2306.1
APA PDS
Supplement 3—90
Design and Fabrication of Plywood Stressed-skin Panels (revised 1996) 2306.1
APA PDS
Supplement 4—90.
Design and Fabrication of Plywood Sandwich Panels (revised 1993) 2306.1
APA PDS
Supplement 5—95
Design and Fabrication of All-plywood Beams (revised 1995) 2306.1
EWS R540—02 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1
EWS S475—01 Glued Laminated Beam Design Tables 2306.1
EWS S560—03 Field Notching and Drilling of Glued Laminated Timber Beams 2306.1
EWS T300—05 Glulam Connection Details 2306.1
EWS X440—03 Product Guide-Glulam 2306.1
EWS X450—01 Glulam in Residential Construction —Western Edition 2306.1

APSP The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
ANSI/APSP 7—06 Standard for Suction Entrapment Avoidance in Swimming Pools,
Wading Pools, Spas, Hot Tubs and Catch Basins
3109.3.1.1

AREMA American Railway Engineering and Maintenance-of-Way Association
10003 Derekwood Lane, Suite 210
Lanham, Maryland 20706
Standard
reference
number
Title Referenced
in code
section number
AREMA—2012 Manual for Railway Engineering 1607.8.3

ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
Standard
reference
number
Title Referenced
in code
section number
EP 484.2 (2003) Diaphragm Design of Metal-clad, Post-frame Rectangular Buildings 2306.1
EP 486.1 (2000) Shallow-post Foundation Design 2306.1
EP 559 (1997) Design Requirements and Bending Properties for Mechanically Laminated Columns 2306.1

ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
3—91 Structural Design of Composite Slabs 1604.3.3, 2209.2.1
5—08 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, 1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1704.5.3, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2104.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2110.1
6—08 Specifications for Masonry Structures 1405.6.1, Table 1704.5.1, Table 1704.5.3, 2103.8, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.3, 2104.4, 2104.6, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3, 2105.4
7—05 Minimum Design Loads for Buildings and Other Structures including
Supplements No.1 and 2, excluding Chapter 14 and Appendix 11A
Table 1504.8, 1602, 1603.1.8, 1604.8.2, 1605.2.2 1605.3.1.2, Table 1607.1, 1607.11.1, 1608.1, 1608.3, 608.3.5, 1608.3.6, 1608.4, 1608.5, 1608.6, 1608.7, 1608.8, 1608.9, 1609.1.1, 1609.1.1.2.1, 1609.1.1.2.2, 1609.7.3, 1611.2, 1908.1.1, 1908.1.2, 2205.2.1, 2205.3, 2205.3.1, 2208.1, Table 2308.10.1, 2404.1, 2505.1, 2505.2, G104.5.2, G201.2, G304.2, G402
7—10 Minimum Design Loads for Buildings and Other Structures 909.10.6, 1602, 1604.3, 1604.10, 1605.1, 1613.1, 1613.2, 1613.5.5.1, 1613.5.6, Table 1613.5.6(2), 1613.5.6.1, 1613.5.6.2, 1613.6, 1613.6.1, 1613.7, 1613.8, Table 1613.8, 1801.2.1, 1808.9.2.1, 1808.9.3.2, 1808.9.3.4, 1813.2.1, 1908.1.9
8—02 Standard Specification for the Design of Cold-formed Stainless Steel Structural Members 1604.3.3, 2209.1
19—96 Structural Applications of Steel Cables for Buildings 2207.1, 2207.2
24—05* Flood Resistant Design and Construction G103.1, G104.3, G104.5.1, G104.5.2, G105.2, G105.4, G201.2, G301.1, G303.2, G303.3, G303.4,G303.7, G304.1.1, G304.1.2, G304.2, G304.3, G305.1, G307.1, G307.2, G307.3, G308.1, G308.3, G310.3, G402, G501.1
29—05 Standard Calculation Methods for Structural Fire Protection 721.1
32—01 Design and Construction of Frost Protected Shallow Foundations 1805.3.1
*As modified in Appendix G

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A17.1—00* with
supplements A17.1a—02 and
A17.1b—03
Safety Code for Elevators and Escalators 1007.4, 1109.6.1, 1607.8.1, 2409.1, 2409.2, 2409.3, 3001.2, 3001.4, 3001.9, 3002.1.1, 3002.5, 3002.8, 3003.2, 3003.3.1, 3003.3.3, 3009.3, K101.1, K1-6.1.3.5.4, K1-Table N1, K2-6.21.2, K2-6.21.3, K3-1.5, K3-2.6.7, K3-2.6.7, K3-3.8.4.1, K4-1.1
A17.1—2010* Safety Code for Elevators and Escalators 907.3.3, 911.1.5, K4-2.18.5.1, K4-2.20.3, K4-2.20.4
A17.1s—2005* Supplement to Safety Code for Elevators and Escalators 3001.2, K4-401.1
A17.2—2002 Safety Code For Existing Elevators And Escalators 3001.2, K1-8.10.2.2.2, K1-8.10.4.1.1
A17.3—02 Guide for Inspection of Elevators, Escalators & Moving Walk, Elevator
Industry Inspection Handbook
3001.2, K1- 2.12.6.2.6, K301.1, K3-2.7.2, K3-3.10.12
A17.5—2004 Elevator and Escalator Electrical Equipment 3001.2
A17.6—2010* Standard for Elevator Suspension, Compensation, and Governor Systems K4-2.18.5.1. K4-2.20.3, K4-2.20.4
A18.1—2005 Safety Standard for Platform Lifts and Stairway Chairlifts 1007.5, 1109.7, 3001.2, K1-Table N1
A90.1—03 Safety Standard for Belt Manlifts 3001.2, K1-Table N1
B16.18—2001
(Reaffirmed 2005)
Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1
B16.22—2001
(Reaffirmed 2005)
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1
B20.1—2006* Safety Standard for Conveyors and Related Equipment 3001.2, 3005.3, K1-Table N1, K1-7.4.2, K2-201.1
B 31.3—2004 Process Piping 415.8.6.1
*As modified in Appendix K

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 36—05 Specification for Carbon Structural Steel 1809.7.1
A 153—05 Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware 2304.9.5
A 240—07 Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate,
Sheet, and Strip for Pressure Vessels and for General Applications
Table 1507.4.3(1)
A 252—98(2002) Specification for Welded and Seamless Steel Pipe Piles 1809.7.1, 1810.6.1
A 283—03 Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1809.7.1, 1810.6.1
A 307—04e01 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength 1911.1
A 416—06 Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1809.6.3.1
A 463 T2 65—05 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2)
A 572—07 Specification for High-strength Low-alloy Columbium-vanadium Structural Steel 1809.7.1
A 588—05 Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa)
Minimum Yield Point to 4 inches (100 mm) Thick
1809.7.1
A 615—04a Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1810.7.2.1, 1810.8.1
A 653—07 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated
Galvannealed by the Hot-dip Process
2211.2.2, 2211.2.2.1, 2304.9.5.1
A 653 G-90—07 Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated
Galvannealed by the Hot-dip Process
Table 1507.4.3(1), Table 1507.4.3(2)
A 690—07 Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-Piles and
Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments
1809.7.1
A 706—05a Specification for Low-alloy Steel Deformed and Plain Bars for
Concrete Reinforcement
1704.4.1, 1903.5.2, 2107.4, 2108.3
A 722—07 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.7.2.1, 1810.8.1
A 755—03 Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the
Coil-coating Process for Exterior Exposed Building Products
Table 1507.4.3(1), Table 1507.4.3(2)
A 792/A 792M—06a Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the
Hot-Dip Process
Table 1507.4.3(1), Table 1507.4.3(2)
A 875/A 875M—06 Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated
by the Hot Dip Process
Table 1507.4.3(2)
A 913—04 Specification for High-strength Low-alloy Steel Shapes of Structural Quality,
Produced by Quenching and Self-tempering Process (QST)
1809.7.1
A 924—07 Standard Specification for General Requirements for Steel Sheet,
Metallic-coated by the Hot-dip Process
Table 1507.4.3(1)
A 992/A 992M—06a Standard Specification for Structural Shapes 1809.7.1
B 42—02 (e2001) Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B 43—98 (2004) Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B 68—02 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B 88—03 Specification for Seamless Copper Water Tube 909.13.1
B 101—02 Specification for Lead-coated Copper Sheet and Strip for
Building Construction
1404.5.3, Table 1507.4.3(1), Table 1507.2.9.2
B 209—06 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B 251—02(e01) Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1
B 370—03 Standard Specification for Copper Sheet and Strip for Building Construction 1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1)
B 695—03 Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel 2304.9.5.1, 2304.9.5.3
C 5—03 Specification for Quicklime for Structural Purposes Table 2507.2
C 22/C 22M—00 (2005)e01 Specification for Gypsum Table 2506.2
C 27—98 (2002) Specification for Standard Classification of Fireclay and High-alumina Refractory Brick 2111.5, 2111.8
C 28/C 28M—00 (2005) Standard Specification for Gypsum Plasters Table 2507.2
C 31—06 Practice for Making and Curing Concrete Test Specimens in the Field Table 1704.4, 1905.1.3, 1905.6.3.3, 1905.6.3.3.1 1905.6.3.8, 1905.6.4.2, 3305.3.5.6
C 33—03 Specification for Concrete Aggregates 721.3.1.4, 721.4.1.1.3
C 34—03 Specification for Structural Clay Load-bearing Wall Tile 2103.2
C 35—01 (2005) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C 36/C 36M—03 Specification for Gypsum Wallboard Figure 721.5.1(2), Figure 721.5.1(3), Table2506.2, Table 2508.1
C 37/C 37M—01 Specification for Gypsum Lath Table 2507.2
C 39—12a Test Method for Compressive Strength of Cylindrical Concrete Specimens 1905.6.3.3.3, 1913.5.2, 1913.10.3
C 42—13 Standard Test Method for Obtaining and Testing Drilled Cores and Sawed Beams of Concrete 1913.5.1, 1913.10, 1913.10.1
C 55—06e01 Specification for Concrete Brick Table 721.3.2, 2103.1, 2105.2.2.1.2
C 56—05 Specification for Structural Clay Nonload-bearing Tile 2103.2
C 59/C 59M—00 (2006) Specification for Gypsum Casting and Molding Plaster Table 2507.2
C 61/C 61M—00 (2006) Specification for Gypsum Keene's Cement Table 2507.2
C 62—05 Specification for Building Brick (Solid Masonry Units Made from Clay or Shale) 2103.2, 2105.2.2.1.1
C 67—07 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1, 2104.5, 2105.2.2.1.1
C 73—05 Specification for Calcium Silicate Face Brick (Sand-lime Brick) Table 721.3.2, 2103.1, 2103.2
C 79—04a Specification for Treated Core and Nontreated Core Gypsum Sheathing Board Table 2506.2
C 90—06b Specification for Loadbearing Concrete Masonry Units Table 721.3.2, 2103.1, 2105.2.2.1.2
C 91—05 Specification for Masonry Cement Table 2507.2
C 94—07 Specification for Ready-mixed Concrete 110.3.1, 1905.1.3, 1905.6.3.8, 1905.8.2
C 126—99 (2005) Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units 2103.2
C 129—11 Standard Specification for Nonloadbearing Concrete Masonry Units 2103.1
C138—08 Standard Test Method for Density (Unit Weight) Yield and Air Content (Gravimetric) of Concrete 1905.6.3.6
C 140—07 Test Method Sampling and Testing Concrete Masonry Units and Related Units 721.3.1.2, 2105.2.2.1.2
C143—12 Standard Test Method for Slump of Hydraulic-cement Concrete 1905.6.3.6
C 150—07 Specification for Portland Cement Table 1904.4.2, Table 2507.2
C 172—04 Practice for Sampling Freshly Mixed Concrete Table 1704.4, 1905.6.3.2
C173—12 Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method 1905.6.3.6
C 199—84 (2005) Test Method for Pier Test for Refractory Mortars 2111.5, 2111.8, 2113.12
C 206—03 Specification for Finishing Hydrated Lime Table 2507.2
C 208—95 (2001) Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.5
C 212—00 (2006) Specification for Structural Clay Facing Tile 2103.2
C 216—07 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) 2103.2, 2105.2.2.1.1, Table 720.1(2)
C 231—10 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method 1905.6.3.6
C 260—06 Standard Specification for Air-entraining Admixtures for Concrete 1905.3.4
C 270—07 Specification for Mortar for Unit Masonry 2103.8, 2108.3
C 315—07 Specification for Clay Flue Liners and Chimney Pots 2111.8, 2113.11.1, Table 2113.16(1)
C 317—00 (2010) Standard Specification for Gypsum Concrete 1914.1
C 330—05 Specification for Lightweight Aggregates for Structural Concrete 721.1.1, 1905.1.4
C 331—05 Specification for Lightweight Aggregates for Concrete Masonry Units 721.3.1.4, 721.4.1.1.3
C 406—06e01 Specification for Roofing Slate 1507.7.5
C 442/C 442M-04 Specification for Gypsum Backing Board and Coreboard and Gypsum Shaftliner Board 2506.2
C 472—99 (2004) Specification for Standard Test Methods for Physical Testing of Gypsum,
Gypsum Plasters and Gypsum Concrete
2506.2
C 473—06a Test Method for Physical Testing of Gypsum Panel Products 2506.2
C 474—05 Test Methods for Joint Treatment Materials for Gypsum Board Construction 2506.2
C 475/C 475M—02(2007) Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard 2506.2
C 476—10 Specification for Grout for Masonry 2102
C 494—13 Standard Specification for Chemical Admixtures for Concrete 1905.3.4
C 503—05 Specification for Marble Dimension Stone (Exterior) 2103.4
C 511—09 Standard Specification for Mixing Rooms, and Water Storage Tanks
Used in the Testing of Hydraulic Cements and Concretes
1905.6.3.3.2
C 514—04 Specification for Nails for the Application of Gypsum Board Table 720.1(2), Table 720.1(3), 2506.2
C 516—02 Specifications for Vermiculite Loose Fill Thermal Insulation 721.3.1.4, 721.4.1.1.3
C 547—06 Specification for Mineral Fiber Pipe Insulation Table 720.1(2), Table 720.1(3)
C 549—06 Specification for Perlite Loose Fill Insulation 721.3.1.4, 721.4.1.1.3
C 552—03 Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C 557—03e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing 2506.2
C 568—03 Specification for Limestone Dimension Stone 2103.4
C 578—07 Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2
C 587—04 Specification for Gypsum Veneer Plaster Table 2507.2
C 588/C 588M—01 Specification for Gypsum Base for Veneer Plasters Table 2507.2
C 595—07 Specification for Blended Hydraulic Cements 1904.4.2, Table 2507.2
C 615—03 Specification for Granite Dimension Stone 2103.4
C 616—03 Specification for Quartz Dimension Stone 2103.4
C 618—99 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan
for Use as a Mineral Admixture in Concrete
Table 1904.4.2
C 622—03 Specification for Slate Dimension Stone 2103.4
C 630/C 630M—03 Specification for Water-resistant Gypsum Backing Board Table 2506.2, 2509.2
C 631—95a (2004) Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
C 635—00* Specification for the Manufacture, Performance, and Testing of Metal Suspension
Systems for Acoustical Tile and Lay-in Panel Ceilings
808.1.1.1, R101.1, R102.1, R102.2, R102.3, Q102.1
C 636—96* Practice for Installation of Metal Ceiling Suspension Systems
for Acoustical Tile and Lay-in Panels
808.1.1.1, R101.1, R103.1, R103.2, R103.3, R103.4, R103.5, R103.6, R103.7, R103.8, R103.9, R103.10, R103.11, R 103.12, R103.13, R103.14
C 645—07 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2
C 652—05a Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale) 2103.2, 2105.2.2.1.1
C 685—11 Standard Specification for Concrete Made by Volumetric Batching 1905.8.2
C 728—05 Specification for Cellulosic Fiber Insulating Board Table 1508.2
C 744—05 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 721.3.2, 2103.1
C 754—04 Specification for Installation of Steel Framing Members to Receive Screw-attached
Gypsum Panel Products
Table 2508.1, Table 2511.1
C 836—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Separate Wearing Course
1507.15.2
C 840—07 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2
C 841—03 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1
C 842—05 Specification for Application of Interior Gypsum Plaster Table 2511.1, 2511.3, 2511.4
C 843—99 (2006) Specification for Application of Gypsum Veneer Plaster Table 2511.1
C 844—04 Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C 845—96 Specification for Expansive Hydraulic Cement Table 1904.4.2
C 847—06 Specification for Metal Lath Table 2507.2
C 887—05 Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 2103.9
C 897—05 Specification for Aggregate for Job-mixed Portland Cement-based Plasters Table 2507.2
C 920—05 Standard Specification for Elastomeric Joint Sealants Table 2506.2
C 926—98a (2005) Specification for Application of Portland Cement Based-plaster 2510.3, Table 2511.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7
C 931/C 931M—04 Specification for Exterior Gypsum Soffit Board Table 2508.1, Table 2506.2, 2508.2
C 932—06 Specification for Surface-applied Bonding Agents for Exterior Plastering Table 2507.2
C 933—05 Specification for Welded Wire Lath Table 2507.2
C 946—91 (2001) Specification for Practice for Construction of Dry-stacked, Surface-bonded Walls 2103.9, 2109.2.2
C 954—04 Specification for Steel Drill Screws for the Application of
Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to
0.112 inch (2.84 mm) in Thickness
2211.2.2.3, Table2506.2, Table 2507.2
C 955—06 Standard Specification for Load-bearing Transverse and Axial Steel Studs,
Runners Tracks, and Bracing or Bridging, for Screw Application of
Gypsum Panel Products and Metal Plaster Base
Table 2506.2, Table 2507.2
C 956—97 Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 1914.1
C 957—06 Specification for High-solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane with Integral Wearing Surface
1507.15.2
C 960—04 Specification for Predecorated Gypsum Board Table 2506.2
C 989—99 Specification for Ground Granulated Blast-furnace Slag for Use in Concrete and Mortars Table 1904.4.2
C 1002—04 Specification for Steel Self-piercing Tapping Screws for the Application of
Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
Table 2506.2, Table 2507.2
C 1007—04 Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and
Related Accessories
Table 2508.1, Table 2511.1
C 1019—05 Test Method of Sampling and Testing Grout 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3
C 1029—05a Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C 1032—96 Specification for Woven Wire Plaster Base Table 2507.2
C 1047—05 Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base Table 2506.2, Table 2507.2
C 1063—06 Specification for Installation of Lathing and Furring to Receive Interior and
Exterior Portland Cement-based Plaster
2510.3, Table 2511.1, 2512.1.1
C 1064—12 Standard Test Method for Temperature of Freshly Mixed Hydraulic-cement Concrete 1905.6.3.6
C 1088—07a Specification for Thin Veneer Brick Units Made from Clay or Shale Table 720.1(2), 2103.2
C 1157—00 Performance Specification for Hydraulic Cement Table 1904.4.2
C 1167—03 Specification for Clay Roof Tiles 1507.3.4
C 1177/C 1177M—06 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 2506.2
C 1178/C 1178M—06 Specification for Coated Mat Water-resistant Gypsum Backing Panel Table 2506.2, 2509.2
C 1186—07 Specification for Flat Nonasbestos Fiber Cement Sheets 1401.10, 1405.16.1, 1405.16.2
C 1492—03 Standard Specification for Concrete Roof Tile 1507.3.5
C 1240—00E1 Specification for Silica Fume for Use as a Mineral Admixture in
Hydraulic-cement Concrete, Mortar and Grout
Table 1904.4.2
C 1261—07 Specification for Firebox Brick for Residential Fireplaces 2111.5, 2111.8
C 1278/C 1278M—06 Specification for Fiber-reinforced Gypsum Panels Table 2506.2
C 1280—04 Specification for Application of Gypsum Sheathing Table 2508.1, 2508.2
C 1283—07 Practice for Installing Clay Flue Lining 2113.12
C 1288—99 (2004) Standard Specification for Discrete Nonasbestos Fiber-cement Substrate Sheets 2509.2
C 1289—07 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2
C 1314—07 Test Method for Compressive Strength of Masonry Prisms 2105.2.2.2.2, 2105.3.1, 2105.3.2
C 1325—04 Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Substrate Sheets 2509.2
C 1328—05 Specification for Plastic (Stucco Cement) Table 2507.2
C 1371—04a (2010)e1 Standard Test Method for Determination of Emittance of Materials Near Room
Temperature Using Portable Emissometers
1504.9
C 1386—07 Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units 2102.1, 2103.3, 2105.2.2.1.3
C 1395/1395M—04 Specification for Gypsum Ceiling Board Table 2506.2
C 1396/C 1396M—06a Specification for Gypsum Board Table 2506.2, Table 2508.1
C 1405—07 Standard Specification for Glazed Brick (Single-fired, Solid Brick Units) 2103.2
C 1492—03 Standard Specification for Concrete Roof Tile 1507.3.5
C 1549—09 Standard Test Method for Determination of Solar Reflectance Near Ambient
Temperature Using a Portable Solar Reflectometer
1504.9
C 1629/C 1629M—06 Standard Classification for Abuse-resistant Nondecorated Interior Gypsum
Panel Products and Fiber-reinforced Cement Panels
403.2.3.1, 403.2.3.2, 403.2.3.4
C 1658/C 1658M—06 Standard Specification for Glass Mat Gypsum Panels Table 2506.2
D 25—99 (2005) Specification for Round Timber Piles 1809.5.1, 1809.5.4, 2303.1.11
D 41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 43—00 Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 56—05 Test Method for Flash Point by Tag Closed Tester 307.2
D 86—07a Test Method for Distillation of Petroleum Products at Atmospheric Pressure 307.2
D 93—07 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 307.2
D 225—04 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D 226—06 Specification for Asphalt-Saturated Organic Felt Used in Roofing
and Waterproofing
1404.2, 1507.2.3, 1507.3.3, 1507.5.3, 1507.6.3, 1507.7.3, Table 1507.8, 1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2
D 227—03 Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D 312—00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2
D 448—03a Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3, 1507.13.3
D 450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D 635—06 Test Method for Rate of Burning and/or Extent and Time of Burning of
Self-supporting Plastics in a Horizontal Position
2606.4, H107.1.1, H117.4
D 692—09 Standard Specification for Coarse Aggregate for Bituminous Paving Mixtures 1917.2
D 1073—11 Standard Specification for Fine Aggregate for Bituminous Paving 1917.2
D 1143-—07 Test Method for Piles Under Static Axial Compressive Load 1804.4.1.3, 1812.4.1
D 1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2
D 1557—02e01 Test Method for Laboratory Compaction Characteristics of Soil Using
Modified Effort (56,000 ft-lb/ft3 (2,700 KN m/m3))
1804.2.2
D 1586—99 Specification for Penetration Test and Split-barrel Sampling of Soils 1613.5.5, 1802.5
D 1587—00 Standard Practice for Thin-walled Tube Sampling of Soils for Geotechnical Purposes 1802.5
D 1761—06 Test Method for Mechanical Fasteners in Wood 1716.1.1, 1716.1.2, 1716.1.3
D 1863—05 Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D 1929—96 (2001)e01 Test Method for Determining Ignition Properties of Plastics 402.16.4, 1407.11.2.1, 2606.4
D 1970—01 Specification for Self-adhering Polymer Modified Bituminous Sheet Materials
Used as Steep Roof Underlayment for Ice Dam Protection
1507.2.3, 1507.2.4, 1507.2.9.2, 1507.3.9, 1507.5.7, 1507.8.8, 1507.9.9
D 2113—08 Standard Practice for Rock Core Drilling and Sampling of Rock for Site Investigation 1802.5
D 2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 2166—00 Standard Test Method for Unconfined Compressive Strength of Cohesive Soil 1613.5.5
D 2216—05 Test Method for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass 1613.5.5
D 2487—06 Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) Table 1610.1, 1802.3
D 2626—04 Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing 1507.3.3, Table1507.10.2
D 2822—05 Specification for Asphalt Roof Cement Table 1507.10.2
D 2823—05 Specification for Asphalt Roof Coatings Table 1507.10.2
D 2843—99 (2004)e01 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D 2850—03a Standard Test Method for Unconsolidated-Undrained Triaxial Compression Test on Cohesive Soil 1613.5.5
D 2898—04 Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing 1505.1, 2303.2.4, 2303.2.6
D 3019—94 (2007) Specification for Lap Cement Used with Asphalt Roll Roofing,
Nonfibered, Asbestos Fibered, and Nonasbestos Fibered
Table 1507.10.2
D 3161—06 Test Method for a Wind Resistance of Asphalt Shingles (Fan Induced Method) 1507.2.7, 1507.2.7.1, Table 1507.2.7.1(2)
D 3200—74 (2005) Standard Specification and Test Method for Establishing Recommended Design
Stresses for Round Timber Construction Poles
2303.1.11
D 3201—07 Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products 2303.2.7
D3273—12 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings
in an Environmental Chamber
2506.3
D 3278—04e01 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 307.2
D 3462—04 Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5
D 3468—99 (2006)e01 Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in
Roofing and Waterproofing
1507.15.2
D 3679—06a Specification for Rigid Poly (Vinyl Chloride (PVC) Siding) 1404.9, 1405.14
D 3689—90 (1995) Method for Testing Individual Piles Under Static Axial Tensile Load 1808.4.2.1, 1812.4.2
D 3737—07 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3
D 3746—02 Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D 3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2
D 3909—97b (2004)e01 Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2, 1507.6.5, Table 1507.10.2
D 3957—06 Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings 2303.1.10
D 3966—07 Standard Test Methods for Deep Foundations Under Lateral Loads 1808.4.3, 1808.4.3.3
D 4022—07 Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2
D 4272—03 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D 4318—00 Standard Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils 1613.5.5
D 4434—06 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D 4479—07 Specification for Asphalt Roof Coatings - Asbestos-free Table 1507.10.2
D 4586—00 Specification for Asphalt Roof Cement, Asbestos-free Table 1507.10.2
D 4601—04 Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2
D 4637—04 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D 4869—05e01 Specification for Asphalt-saturated (Organic Felt) Underlayment Used
in Steep Slope Roofing
1507.2.3, 1507.5.3, 1507.6.3, 1507.7.3, 1507.8.3, 1507.9.3
D 4897—01 Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D 4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D 4945—00 Test Method for High-strain Dynamic Testing of Piles 1808.4.1.4
D 5019—07 Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2
D 5034—09 Standard Test Method for Breaking Strength and Elongation of Textile Fabrics (Grab Test) 3308.6.3
D 5035—11 Standard Test Method for Breaking Force and Elongation of Textile Fabrics (Strip Method) 3308.6.3
D 5055—05 Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-Joists 2303.1.2
D 5096—02-11 Standard Test Method for Determining the Performance of a Cup Anemometer or Propeller Anemometer 3314.4.4.6
D 5456—05a Specification for Evaluation of Structural Composite Lumber Products 2303.1.9
D 5516—03 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the
Elevated Temperatures
2303.2.5.1
D 5643—06 Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2
D 5664—02 Test Methods for Evaluating the Effects of Fire-retardant Treatment and
Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber
2303.2.5.2
D 5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing Table 1507.10.2
D 5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing Table 1507.10.2
D 6066—11 Standard Practice for Determining the Normalized Penetration Resistance of Sands for
Evaluation of Liquefaction Potential
1813.2
D 6083—05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, 1507.15.2
D 6162—00A Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
1507.11.2
D 6163—00 E01 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using Glass Fiber Reinforcements
1507.11.2
D 6164—05 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Metal Materials Using Polyester Reinforcements
1507.11.2
D 6222—02e01 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet
Materials Using Polyester Reinforcements
1507.11.2
D 6223—02 Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet
Materials Using a Combination of Polyester and Glass Fiber Reinforcements
1507.11.2
D 6298—05 Specification for Fiberglass Reinforced Styrene-Butadiene-Styrene (SBS)
Modified Bituminous Sheets with a Factory Applied Metal Surface
1507.11.2
D 6305—02e01 Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated
Plywood Roof Sheathing
2303.2.5.1
D 6380—03 Standard Specification for Asphalt Roll Roofing (Organic Felt) 1507.2.9.2, 1507.3.3, 1507.6.5
D 6509—00 Standard Specification for Atactic Polypropylene (APP) Modified Bituminous Base Sheet
Materials Using Glass Fiber Reinforcements
1507.11.2
D 6694—07 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used
in Spray Polyurethane Foam Roofing Systems
1507.15.2
D 6754—02 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D 6757—07 Standard Specification for Underlayment Felt Containing Inorganic
Fibers Used in Steep-slope Roofing
1507.2.3
D 6841—03 Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber 2303.2.5.2
D 6878—06a Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
D 6947—07 Standard Specification for Liquid-applied Moisture Cured Polyurethane
Coating Used in Spray Polyurethane Foam Roofing System
1507.15.2
D 7158—07 Standard Test Method for Wind Resistance of Asphalt Shingles
(Uplift Force/Uplift Resistance Method)
1507.2.7.1, Table 1507.2.7.1(1)
E 84—07 Test Methods for Surface Burning Characteristics of Building Materials 402.16.4, 402.11, 703.4.2, 719.1, 719.1.1, 719.1.2, 719.4, 802.1, 803.1, 803.1.1, 803.1.2, 803.1.4, 803.1.4.1, 806.5, 1407.9, 1407.10.1, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2604.2.4, 2606.4, 2613.3, K1-2.14.2.1.1, K1-2.15.8, K4-2.14.2.1
E 90—04 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of
Building Partitions and Elements
1207.2, 1207.2.1
E 96—00 Test Method for Water Vapor Transmission of Materials 202
E 108—07a Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
E 119—07 Test Methods for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.3, 703.5, 704.12, 705.7, 705.8.5, 707.6; 712.3.2, 713.3.1, 713.4.1.1, 714.1, 714.4, 715.2, 715.4.5, 716.5.2, 716.5.3, 716.6.1, 716.6.2.1, Table 720.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
E 136—04 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.4.1, 719.1.1
E 330—02 Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by
Uniform Static Air Pressure Difference
1715.5.2
E 331—01 Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by
Uniform Static Air Pressure Difference
1403.2
E 336—05 Standard Test Method for Measurement of Airborne Sound Insulation in Buildings 1207.2
E 408—13 Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques 1504.9
E 492—04 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling
Assemblies Using the Tapping Machine
1207.3
E 605—93 (2006) Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM)
Applied to Structural Members
1704.11.4.1, 1704.11.4.2, 1704.11.4.3, 1704.11.5
E 648—06a Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a
Radiant Heat Energy Source
804.2, 804.3
E 681—04 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 307.2
E 736—00 (2006) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to
Structural Members
704.13.3.2, 1704.11.6
E 814—06 Test Method of Fire Tests of Through-penetration Firestops 702.1, 713.3.1.2, 713.3.2, 713.4.1.1.2
E 970—00 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using
a Radiant Heat Energy Source
719.3.1
E 1007—97 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission
through Floor-ceiling Assemblies and Associated Support Structures
1207.3
E 1300—04e01 Practice for Determining Load Resistance of Glass in Buildings 2401.1, 2402.2, 2404.3, 2404.3.3, 2404.3.4, 2404.3.5
E 1354—04a Standard Test Method for Heat and Visible Smoke Release Rates for Materials and
Products Using an Oxygen Consumption Calorimeter
402.12.1
E 1592—01 Test Method for Structural Performance of Sheet Metal Roof and
Siding Systems by Uniform Static Air Pressure Difference
1504.3.2
E 1602—03 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E 1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials 1609.1.2
E 1918—06 Standard Test Method for Measuring Solar Reflectance of Horizontal and
Low-sloped Surfaces in the Field
1504.9
E 1966—01 Test Method for Fire-resistant Joint Systems 702.1, 714.3
E 1980—11 Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces 1504.9
E 1996—06 Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 1609.1.2, 1609.1.2.1
E 2072—10 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings 1024.4
E 2174—09 Standard Practice for Onsite Inspection of Installed Fire Stops 1704.2.7.1
E 2273—07 Standard Practice for Specimen Preparation and Mounting of Site-fabricated
Stretch Systems to Access Surface Burning Characteristics
1408.4.1
E 2307—04e01 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems
Using Intermediate-scale, Multistory Test Apparatus
714.4
E 2393—10a Standard Practice for On-site Inspection of Installed Fire Resistive Joint Systems
and Perimeter Fire Barriers
1704.27.2
E 2404—07a Standard Practice for Specimen Preparation and Mounting of Textile, Papter or Vinyl Wall or
Ceiling Coverings to Assess Surface Burning Characteristics
803.1
E 2568—07 Standard Specification for PB Exterior Insulation and Finish Systems 1408.2
E 2570—07 Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings
Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
1408.4.1.1, 1704.13.2
E 2573—07 Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch
to Assess Surface Burning Characteristics
803.1
E 2634—08 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems 1903.9
E 2751—12 Standard Practice for Design and Performance of Supported Laminated Glass Walkways 2405.1.1
F 547—01 Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F 1346—91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for
Swimming Pools, Spas and Hot Tubs
3109.3.2.1, 3109.4,3109.5.1.8, 3109.6
F 1667—05 Specification for Driven Fasteners: Nails, Spikes, and Staples Table 720.1(2), Table 720.1(3), 1507.2.6, 2303.6, Table 2506.2
F 2090—01a (2007) Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms 1405.13.2
F 2200—05 Standard Specification for Automated Vehicular Gate Construction 3110.3
F 2208—08 Standard Safety Specification for Residential Pool Alarms 3109.3.2.1
G 152—06 Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
G 154—05 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6
G 155—05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6
* As modified in Appendix R, where applicable pursuant to Section 808.1.1.1

AWPA American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
Title Referenced
in code
section number
C1—03 All Timber Products-Preservative Treatment by Pressure Processes 1505.6
C3—03 Piles-Preservative Treatment by Pressure Processes 1809.5.2
C24—03 Sawn Timber Piles Used to Support Residential and Commercial Building 1809.5.2
M4—06 Standard for the Care of Preservative-treated Wood Products 1809.5.2, 2303.1.8
U1—07 USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6,
Commodity Specification H
Table 1507.9.6, 2303.1.8, 2304.11.2, 2304.11.4, 2304.11.6, 2304.11.7

AWS American Welding Society
550 N.W. LeJeune Road
Miami, FL 33126
Standard
reference
number
Title Referenced
in code
section number
D1.1—04 Structural Welding Code-Steel 1704.3.1.1, Table 1704.3, K1-8.8.1
D1.2—03 Structural Welding Code-Aluminum 1704.28.1, 2003.2.2
D1.3—98 Structural Welding Codes-Sheet Steel 1704.3.1.2, Table 1704.3, Table 1704.3.4
D1.4—98 Structural Welding Code-Reinforcing Steel 1704.3.1.3, Table 1704.3, Table 1704.4, 1903.5.2, 2107.4

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C 104—95 American National Standard for Cement-Mortar Lining for
Ductile-Iron Pipe and Fittings for Water
Q105.1

AWCI Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046
Standard
reference
number
Title Referenced
in code
section number
12-B—98 Technical Manual 12-B Standard Practice for the Testing and Inspection of
Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide, First Edition
1704.12

BHMA Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
Standard
reference
number
Title Referenced
in code
section number
A 156.10—06 Power Operated Pedestrian Doors 1008.1.4.2
A 156.19—02 Standard for Power Assist and Low Energy Operated Doors 1008.1.4.2

CAN/ULC Standards Council of Canada
270 Albert Street, Suite 200
Ottawa, Ontario, Canada KIP 6N7
Standard
reference
number
Title Referenced
in code
section number
S102.2—1988 Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings, and Miscellaneous
Materials and Assemblies with 2000 Revisions
719.4
S635—00 Standard for Lining Systems for Existing Masonry or Factory-built Chimneys and Vents 2113.11.1.2, 2113.19

CGSB Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
37-GP—52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2
37-GP—56M (1980) Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December Revisions 1507.11.2
37.54—95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2

CPA Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4—2004 Basic Hardboard 2303.1.6
ANSI A135.5—2004 Prefinished Hardboard Paneling 2303.1.6, 2304.6.2
ANSI A135.6—1998 Hardboard Siding 2303.1.6

CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesada, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1201(1977) Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.1, 2409.2, 2409.3.1
16 CFR Part 1209 (1979) Interim Safety Standard for Cellulose Insulation 719.6
16 CFR Part 1404 (1979) Cellulose Insulation 719.6
16 CFR Part 1500.44 (2001) Method for Determining Extremely Flammable and Flammable Solids 307.2
16 CFR Part 1630 (2000) Standard for the Surface Flammability of Carpets and Rugs 804.4.1

CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
101/I.S.2/A440—08 Standard/Specification for Windows, Doors and Skylights 1715.5.1, 2405.5

DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
ANSI/DASMA 107—1997
(R2004)
Room Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9
108—05 Standard Method for Testing Sectional Garage Doors and Rolling Doors:
Determination of Structural Performance Under Uniform Static Air Pressure
1715.5.2
115—05 Standard Method for Testing Sectional Garage Doors 1609.1.2.2

DOC U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS-1—07 Structural Plywood 2211.2.2.2, 2303.1.4, 2304.6.2, Table 2304.7(4), Table 2304.7(5), Table 2306.2.1(1), Table 2306.2.1(2)
PS-2—04 Performance Standard for Wood-based Structural-use Panels 2211.2.2.2, Table 2304.7(5), Table 2306.2.1(1), 2303.1.4, 2304.6.2
PS 20—05 American Softwood Lumber Standard 1809.5.1, 2302.1, 2303.1.1

DOJ U.S. Department of Justice
950 Pennsylvania Avenue, NW
Civil Rights Division, Disability Rights Section-NYA
Washington, DC 20530
Standard
reference
number
Title Referenced
in code
section number
36 CFR Part 1192 American with Disabilities Act (ADA) Accessibility Guidelines for
Transportation Vehicles (ADAAG) Department of Justice, 1991
E109.2.4, E112.4

DOL U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
9 CFR Part 1910.1000 (1974) Air Contaminants 902.1

DOTn U.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
49 CFR Parts 100-185 (2005) Hazardous Materials Regulations 307.2
49 CFR Parts 173 (1999) Specification of Transportation of Explosive and Other Dangerous Articles,
UN 0335, UN 0336 Shipping Containers
307.2
49 CFR Parts 173.137(2005) Shippers-General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group 307.2

EN European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
Title Referenced
in code
section number
1081—98 Resilient Floor Coverings-Determination of the Electrical Resistance 406.5.2

FEMA Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
Standard
reference
number
Title Referenced
in code
section number
FIS 360497 Federal Emergency Management Agency Flood Insurance Study report G102.2, G402
FIRMs 360497 Federal Emergency Management Agency Flood Insurance Rate Map G102.2, G102.3, G102.3.1, G102.3.2, G103.3, G104.8, G201.2, G402
FORM 086-0-34—12 Floodproofing Certificate; Federal Emergency Management Agency G105.3, G402
FORM 086-0-33—12 Elevation Certificate; Federal Emergency Management Agency G105.3, G402

FM Factory Mutual
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnson, R1 02919
Standard
reference
number
Title Referenced
in code
section number
4450 (1989) Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements thru 7/92 1508.1, 2603.3, 2603.4.1.5
4470 (1992) Approval Standard for Class 1 Roof Covers 1504.7
4474 (2004) Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies
Using Static Positive and/or Negative Differential Pressures
1504.3.1
4880 (2005) American National Standard for Evaluating Insulated Wall or Wall and Roof/
Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels,
Wall/Ceiling Coating Systems, Interior and Exterior Finish Systems
2603.4, 2603.9
DS 1-35 (2011) Factory Mutual Data Sheet-Green Roof Systems 1507.16.1

GA Gypsum Association
810 First Street N.E. #510
Washington, DC 20002-4268
Standard
reference
number
Title Referenced
in code
section number
GA 216—07 Application and Finishing of Gypsum Panel Products Table 2508.1, 2509.2
GA 600—06 Fire-resistance Design Manual, 18th Edition Table 720.1(1), Table 720.1(2), Table 720.1(3)

HPVA Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190-5350
Standard
reference
number
Title Referenced
in code
section number
HP-1—2004 Standard for Hardwood and Decorative Plywood 2303.3, 2304.6.2

HUD U.S. Department of Housing and Urban Development
451 7th Street, SW
Washington, DC 20410
Standard
reference
number
Title Referenced
in code
section number
HUD 24 CFR Part 3280 (1994) Manufactured Home Construction and Safety Standards G201.2, G402

ICC International Code Council
500 New Jersey Ave. NW, 6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
ICC/ANSI A117.1—09 Accessible and Usable Buildings and Facilities 406.2.2, 907.2.11.4, 1007.6.5, 1007.9, 1010.1, 1010.6.5, 1010.9, 1011.3, 1022.8.3, 1101.2, 1102.1, 1103.2.3.1, 1104.4, 1105.1.5, 1105.1.6.1, 1106.1, 1106.2.7, 1106.5, 1106.6, 1106.7, 1107.2, 1107.2.1, 1107.2.2, 1107.2.3, 1107.2.3.1, 1107.2.3.2, 1107.2.3.3, 1107.2.3.4, 1107.2.3.5, 1107.2.4, 1107.2.5, 1107.2.6, 1107.2.8, 1107.3.1, 1107.4, 1107.6.1.3, 1108.2.2, 1108.2.3, 1108.2.5, 1108.2.7, 1108.2.9.1, 1108.3, 1108.4, 1108.4.1.1, 1108.4.1.2, 1108.4.1.4, 1108.4.1.5, 1109.1, 1109.2, 1109.2.1.1, 1109.2.2, 1109.2.3, 1109.3, 1109.4, 1109.5.3, 1109.6.1, 1109.7, 1109.8, 1109.13, 1109.15, 1109.16, 1110.4, 1110.4.2, 3001.3, E101.2, E104.2, E104.2.1, E104.3, E104.3.4, E105.1, E105.2.1, E105.2.2, E105.3, E105.4, E105.5, E105.6, E106.2, E106.3, E106.4, E106.4.9, E106.5, E107.2, E107.3, E109.2.1, E109.2.2.1, E109.2.2.2, E109.2.2.3, E109.2.3, E109.2.5, E109.2.6, E109.2.8, E112.4, P101.1, P102.1, P102.2, P102.3, P102.4, P102.6, P102.8.3, P102.8.5, P102.8.6, P102.9.1, P102.9.1.1, P102.9.2, P102.9.2.1, P103.4
ICC 300—07 ICC Standard on Bleachers, Folding and Telescopic Seating, and Grandstands 1028.1, 1028.14.2
ICC 400—07 Standard on Design and Construction of Log Structures 2301.2
ICC 500—08 ICC/NSSA Standard on the Design and Construction of Storm Shelters 423.1, 423.2
ICC 600—08 Standard for Residential Construction in High Wind Regions 1609.1.1.1, 2308.2.1
SBCCI SSTD 11—97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1716.2.1, 1716.2.2

ISO International Organization for Standardization
180 Central Secretariat
1ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
ISO 8115—86 Cotton Bales-Dimensions and Density Table 415.8.2.1.1
ISO 8115-3—95 Bales-Part 3: Bales of Cotton-Packaging and Labeling Table 307.1(1)

NAAMM National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137
Standard
reference
number
Title Referenced
in code
section number
FP 1001—97 Guide Specifications for Design of Metal Flag Poles 1609.1.1

NCMA National Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 22071-4662
Standard
reference
number
Title Referenced
in code
section number
TEK 5—84 (1996) Details for Concrete Masonry Fire Walls Table 720.1(2)

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
13—07* Installation of Sprinkler Systems Table 903.2.11.10, 705.8.2, 708.2, 901.1.1, 903.3.1.1, 903.3.2, 903.3.5.1, 903.3.5.1.1, 903.3.5.2, 905.3.3.1, 907.6.3, 1704.2.3.1, K4-2.8.3.3 Q101.1, Q102.1, Q103.1, Q104.1, Q105.1
13D—07* Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes 901.1.1, 903.3.1.3, 903.3.5.1.1, Q101.1, Q102.1, Q103.1
13R—07* Installation of Sprinkler Systems in Residential Occupancies Up to and Including
Four Stories in Height
903.1.1, 903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4, Q101.1, Q102.1, Q104.1
14—07* Installation of Standpipe and Hose System 403.3.2, 901.1.1, 905.2, 905.3.3.3, 905.4.2, 905.6.2, 905.8, 1704.2.4.1, 3202.2.5, 3303.8.1, Q101.1, Q102.1, Q105.1
20—07* Installation of Stationary Pumps for Fire Protection 901.1.1, 913.1, 913.2, 913.2.1, 913.5, Q101.1, Q105.1, Q106.1
22—08 Standard for Water Tanks for Private Fire Protection Q 1 0 5 . 1
24—10 Standard for the Installation of Private Fire Service Mains and their Appurtenances Q102.1
25—11 Standard for the Inspection, Testing, and Maintenance of Water-based Fire Protection Systems Q102.1
30—08 Flammable and Combustible Liquids Code 415.3
31—06 Installation oil Oil-burning Equipment 2113.15
32—07 Dry-cleaning Plants 415.6.4
40—07 Storage and Handling of Cellulose Nitrate Motion Picture Film 409.1
45—04 Standard on Fire Protection for Laboratories Using Chemicals 424.2, 424.7.1
54—06 National Fuel Gas Code 2113.1
58—08 Liquefied Petroleum Gas Code 415.6.3
61—08 Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities 415.6.1
69—08 Standard on Explosion Prevention Systems 415.6.1
72—10* National Fire Alarm Code 505.4, 901.1.1, 901.6, 903.4.1, 904.3.5, 907.1, 907.2, 907.2.1.1, 907.2.2, 907.2.7, 907.2.11, 907.2.13.3, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2, 907.6, 907.6.1, 907.6.5, 907.7, 907.7.1, 907.7.2, 909.16, 911.1.5, 917.1, 3007.7, Q101.1, Q102.1
80—07 Fire Doors and Other Opening Protectives 410.3.5, 509.4.2, 715.4, 1008.1.4.3, 715.4.6, 715.4.7.1, 715.4.8.2, 715.5, 715.5.5
5—07 Boiler and Combustion System Hazards Code 415.6.1
92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 909.8
99—05 Standard for Health Care Facilities 407.9, 908.8
99C—05 Standard on Gas and Vacuum Systems 908.8
101—06 Life Safety Code 1028.6.2
105—07 Standard for the Installation of Smoke Door Assemblies 405.4.2, 711.5.2, 715.4.3.1, 909.20.4.1
110—05 Emergency and Standby Power Systems 1704.31, 2702.1
111—05 Stored Electrical Energy Emergency and Standby Power Systems 1704.31, 2702.1
120—04 Coal Preparation Plants 415.6.1
170—06 Standard for Fire Safety and Emergency Symbols 1024.2.6.2, 1024.3.1, 1024.6.1
211—10 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
252—03 Standard Methods of Fire Tests of Door Assemblies 715.3, 715.4.1, 715.4.2, 715.4.3, 715.4.7.3.1
253—06 Test for Critical Radiant Flux of Floor Covering Systems Using a
Radiant Heat Energy Source
402.12.1, 406.6.4, 804.2, 804.3
257—07 Standard for Fire Test for Window and Glass Block Assemblies 715.3, 715.4.3.2, 715.5, 715.5.1, 715.5.2, 715.5.9.1
255—06 Standard Method of Test Surface Burning Characteristics of Building Materials K1-2.14.2.1.1, K1-2.15.8, K4-2.14.2.1.1
259—03 Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
265—07 Method of Fire Tests for Evaluating Room Fire Growth Contribution of
Textile Wall Coverings on Full Height Panels and Walls
803.1.3.1
268—07 Standard Test Method for Determining Ignitibility of Exterior Wall Assemblies
Using a Radiant Heat Energy Source
1406.2.1, 1406.2.1.1, 1406.2.1.2, 2603.5.7
269—12 Standard Test Method for Developing Toxic Potency Data for Use in Fire Hazard Modeling 803.5
285—06 Standard Method of Test for the Evaluation of Flammability Characteristics
of Exterior Non-load-bearing Wall Assemblies Containing Combustible Components
1407.10.3, 2603.5.5
286—06 Standard Method of Fire Test for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
403.16.4 803.1.2, 803.1.2.1, 2603.4, 2603.9, 2604.2.4,2613.4
288—07 Standard Method of Fire Tests of Floor Fire Door Assemblies
Installed Horizontally in Fire-resistance-rated Floor Systems
712.8
409—04 Aircraft Hangers 412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5
418—06 Standard for Heliports 412.7.4
484—06 Combustible Metals 415.6.1
651—98 Machining and Finishing of Aluminum and the Production and Handling of Aluminum Powders 415.6.1
654—06 Prevention of Fire & Dust Explosions from the Manufacturing, Processing, and
Handling of Combustible Particulate Solids
415.6.1
655—07 Prevention of Sulfur Fires and Explosions 415.6.1
664—07 Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities 415.6.1
701—10 Standard Methods of Fire Tests for Flame-propagation of Textiles and Films 402.12.1, 801.4, 3102.3.1, 3102.6.1.1, 3105.3, 3308.3.4, 3314.8.2, 3315.1.6, 3315.2.3, H114.2, H114.2.2, H117.4
704—07 Standard System for the Identification of the Hazards of Materials for Emergency Response 414.7.2, 415.2, 424.4
1124—06 Manufacture, Transportation, and Storage of Fireworks and Pyrotechnic Articles 415.3.1
* As modified in Appendix Q

NIST/NBS National Institute of Standards and Technology
U.S. Department of Commerce
100 Bureau Dr. - Stop 3460
Gaithersburg, MD 20899-3460
Standard
reference
number
Title Referenced
in code
section number
BMS 71—41 Fire Tests of Wood and Metal-framed Partitions 721.7
TRBM 44—46 Fire-resistance and Sound-insulation Ratings for Walls, Partitions and Floors 721.7

PCI Precast Prestressed Concrete Institute
209 W. Jackson Boulevard, Suite 500
Chicago, IL 60606-6938
Standard
reference
number
Title Referenced
in code
section number
MNL 124—89 Design for Fire Resistance of Precast Prestressed Concrete 721.2.3.1
MNL 128—01 Recommended Practice for Glass Fiber-reinforced Concrete Panels 1903.8

RMI Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
ANSI MH 16.1—08 Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2208.1

SDI Steel Deck Institute
P.O. Box 25
Fox River Grove, IL 60021
Standard
reference
number
Title Referenced
in code
section number
ANSI/NC 1.0—06 Standard for Noncomposite Steel Floor Deck 2209.2.2, 2209.2.2.1
ANSI/RD 1.0—06 Standard for Steel Floor Deck 2209.2.3

SJI Steel Joist Institute
1173B London Links Drive
Forest, VA 24551
Standard
reference
number
Title Referenced
in code
section number
CJ-1.0—06 Standard Specification for Composite Steel Joists, CJ-series 1604.3.3, 2203.2, 2206.1
JG-1.1—05 Standard Specification for Joist Girders 1604.3.3, 2203.2, 2206.1
K-1.1—05 Standard Specification for Open Web Steel Joists, K-series 1604.3.3, 2203.2, 2206.1
LH/DLH-1.1—05 Standard Specification for Longspan Steel Joists, LH-series
and Deep Longspan Steel Joists, DLH- series
1604.3.3, 2203.2, 2206.1

SPRI Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham, MA 02452
Standard
reference
number
Title Referenced
in code
section number
ES-1—03 Wind Design Standards for Edge Systems Used with Low Slope Roofing Systems 1504.5
RP-14—10 Wind Design Standards for Vegetative Roofing Systems 1507.16.1
VF-1—10 External Fire Design Standard for Vegetative Roofs 1507.16.1
RP-4—02 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4

TIA Telecommunications Industry Association
2500 Wilson Boulevard
Arlington, VA 22201-3834
Standard
reference
number
Title Referenced
in code
section number
TIA-222-G—05 Structural Standards for Steel Antenna Towers and Antenna Supporting Structures 1609.1.1, 3108.1, 3108.2, 3108.4

TMS The Masonry Society
3970 Broadway, Unit 201-D
Boulder, CO 80304-1135
Standard
reference
number
Title Referenced
in code
section number
0216—97 Standard Method for Determining Fire Resistance of Concrete and
Masonry Construction Assemblies
Table 720.1(2), 721.1
302—07 Standard Method for Determining the Sound Transmission Class for Masonry Walls 1207.2.1
402—08 Building Code Requirements for Masonry Structures 1405.6, 1405.6.2, 1405.10, 1604.3.4, 1704.5.1, Table 1704.5.1, 1704.5.2, 1704.5.3, Table 1704.5.3, 2101.2.2, 2101.2.3, 2101.2.4, 2101.2.5, 2101.2.6, 2104.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4, 2107.5, 2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2110.1
602—08 Specification for Masonry Structures Table 1704.5.1, Table 1704.5.3, 2103.8, 2103.11, 2103.12, 2103.13, 2104.1, 2104.1.1, 2104.1.2, 2104.1.3, 2104.3, 2104.4, 2104.6, 2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3, 2105.4

TPI Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
TPI 1—2007 National Design Standards for Metal-plate connected Wood Truss Construction 2303.4.6, 2306.1

UL Underwriters Laboratories
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
9—2000 Fire Tests of Window Assemblies-with Revisions through April 2005 715.3, 715.4.3.2, 715.5, 715.5.1, 715.5.2, 715.5.9.1
10A—98 Tin Clad Fire Doors-with Revisions through March 2003 715.4
10B—97 Fire Tests of Door Assemblies-with Revisions through October 2001 715.4.2
10C—98 Positive Pressure Fire Tests of Door Assemblies—
with Revisions thru November 2001
715.4.1, 715.4.3, 1008.1.10.1
14B—98 Sliding Hardware for Standard Horizontally-mounted Tin Clad Fire Doors
with Revisions through July, 2000
715.4
14C—06 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs 715.4
103—01 Factory-built Chimneys, for Residential Type and Building Heating Appliances—
with Revisions through June 2006
716.2.5.1
127—96 Factory-built Fireplaces—with Revisions through November, 2006 717.2.5.1
214—01 Standard for Tests for Flame-propagation of Fabrics and Films H114.2, H117.4
217—06 Single-and Multiple-station Smoke Alarms-with Revisions through August 2005 907.2.11
263—03 Standard for Fire Test of Building Construction and Materials 607.5.5, 703.2, 703.2.1, 703.2.3,703.3, 703.5, 704.12, 705.7, 705.8.5, 707.6, 712.3.2, 713.3.1, 713.4.1.1, 714.1, 715.2, 715.4.5, 716.5.2, 716.5.3, 716.6.1, 716.6.2.1, Table 720.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1
268—06 Smoke Detectors for Fire Protective Signaling Systems—with Revisions through January 1999 407.7
300—05 Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Areas 904.11
305—07 Panic Hardware 1008.1.10.1
325—02 Door Drapery, Gate, Louver and Window Operations and Systems—
with Revisions through February 2006
406.1.5, 3110.3.1, 3110.4
555—06 Fire Dampers 716.3.1
555C—06 Ceiling Dampers 716.3.1
555S—99 Smoke Dampers-with Revisions through July 2006 716.3.1
580—06 Test for Uplift Resistance of Roof Assemblies-with Revisions through February 1998 1504.3.1, 1504.3.2
641—95 Type L Low—Temperature Venting Systems—with Revisions through April, 1999
723—03 Standard for Test for Surface—burning Characteristics of Building Materials—
with Revisions through May 2005
402.11, 703.4.2, 719.1, 803.1, 803.1.1, 803.1.2, 803.1.4, 803.1.4.1, 806.5, 1407.9, 1407.10.1, 2303.2, 2603.3, 2603.4.1.13, 2603.5.4, 2604.2.4, 2606.4, 2613.3, K1-2.14.2.1.1, K1-2.15.8, K4-2.14.2.1
790—04 Standard Test Methods for Fire Tests of Roof Coverings 1505.1,2603.6, 2610.2, 2610.3
793—03 Standards for Automatically Operated Roof Vents for Smoke and Heat—
with Revisions through April 2004
910.3.1
864—03 Standards for Control Units and Accessories for Fire Alarm Systems
with Revisions through March 2006
909.12, 909.12.3.1
924—06 Standard for Safety Emergency Lighting and Power Equipment 1011.4
1040—96 Fire Test of Insulated Wall Construction—with Revisions thru June 2001 1407.10.2, 2603.4, 2603.9
1256—02 Fire Test of Roof Deck Construction—with Revisions through January 2007 1508.1, 2603.3, 2603.4.1.5
1275—05 Flammable Liquid Storage Cabinets 424.4
1479—03 Fire Tests of Through-penetration Firestops
with Revisions through April 2007
702.1, 713.3.1.2, 713.3.2, 713.4.1.1.2, 713.5
1482—96 Solid Fuel-type Room Heater—with Revisions through November 2006 2112.2, 2112.5
1703—08 Flat-plate Photovoltaic Modules and Panels 1508.1
1715—97 Fire Test of Interior Finish Material—with Revisions through March 2004 1407.10.2
1777—04 Chimney Liners 2113.11.1, 2113.19
1784—01 Air Leakage Tests of Door Assemblies—with Revisions through December 2004 708.14.1, 711.5.2, 715.4.3.1, 715.4.6.1, 715.4.6.3, 1014.4.1, 1014.4.2, 3007.6, 3007.6.3, 3008.7.3
1897—04 Uplift Tests for Roof Covering Systems 1504.3.1
1975—06 Fire Test of Foamed Plastics Used for Decorative Purposes 402.11, 402.12.1, 402.16.5
1994—04 Standard for Luminous Egress Path Marking Systems—
with Revisions through February 2005
411.7, 1024.2.4, 1024.4
2017—00 Standards for General—purpose Signaling Devices and Systems—
with Revisions through August 2005
3109.5.1.8
2034—08 Standard for Single and Multiple Station Carbon Monoxide Alarms 908.7.3
2075—07 Standard for Gas and Vapor Detectors and Sensors 908.7.3
2079—04 Tests for Fire Resistance of Building Joint Systems—
with Revisions through March 2006
702.1, 714.3, 714.6
2196—11 Test for Fire Resistive Cables 909.20.6.1
2200—04 Stationary Engine Generator Assemblies-with Revisions through July 2004 2702.1.2

USC United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Ch. 40 Importation, Manufacture, Distribution and Storage of Explosive Materials 307.2

WDMA Window and Door Manufacturers Association
1400 East Touhy Avenue #470
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—08
Specifications for Windows, Doors and Unit Skylights 1715.5.1, 2405.5