ACCA Air Conditioning Contractors of America
1712 New Hampshire Ave, NW
Washington, DC 20009
Standard
reference
number
Title Referenced in
code section
number
Manual D—95 Residential Duct Systems 603.2
ANSI American National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced in
code section
number
Z21.8—1994 Installation of Domestic Gas Conversion Burners
919.1
Z21.50—2003 Vented Gas Fireplaces 901.6, 901.6.3
Z21.60—2003 Decorative Gas Appliances for Installation in Solid-Fuel Burning Fireplaces
901.6.2
Z21.83—1998 Fuel Cell Power Plants
924.1
ARI Air-Conditioning and Refrigeration Institute
Suite 425
4301 North Fairfax Drive
Arlington, VA 22203
Standard
reference
number
Title Referenced in
code section
number
700—95 Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3
ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
Standard
reference
number
Title Referenced in
code section
number
ASHRAE—2001 ASHRAE Fundamentals Handbook—2001 312.1, 603.2
15—2001 Safety Standard for Refrigeration Systems 1101.6, 1101.11, 1104.2, 1105.7, 1105.8, 1105.10, 1108.1
34—2001 Designation and Safety Classification of Refrigerants 202, 1102.2.1, 1103.1
*52.2—2007 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by
   Particle Size
202, 1102.2.1, 1103.1
*62.1—2010 Ventilation for Acceptable Indoor Air Quality
*62.2—2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings
ASHRAE—2000 HVAC Systems and Equipment Handbook—2000 312.1
*Section MC 1502 was amended by: Local Law 72 of 2011—Update #58. This law has an effective date of January 01, 2013.
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced in
code section
number
B1.20.1—1983 (R1999) Pipe Threads, General Purpose (Inch)
1203.3.5, 1303.3.3
B16.3—1999 Malleable Iron Threaded Fittings, Classes 150 & 300
Table 1202.5
B 16.5—1996 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24—With B16.5a-1998 Addenda Table 1202.5
B 16.9—1993 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—1996 Forged Fittings, Socket-Welding and Threaded
Table 1202.5
B16.15—1985(R1994) Cast Bronze Threaded Fittings Table 1202.5
B16.18—1984(R1994) Cast Copper Alloy Solder Joint Pressure Fittings Table 1202.5
B 16.22—1995 Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
   —with B16.22a-1998 Addenda.
513.13.1, Table 1202.5
B 16.23—1992 Cast Copper Alloy Solder Joint Drainage Fittings DWV
513.13.1, Table 1202.5
B16.24—1991 (R1998) Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300,
   400, 600, 900, 1500 and 2500.
Table 1202.5
B 16.26—1988 Cast Copper Alloy Fittings for Flared Copper Tubes Table 1202.5
B 16.28—1994 Wrought Steel Butt welding Short Radius Elbows and Returns
Table 1202.5
B 16.29—1994 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV Table 1202.5
B31.1—2004 Power Piping Code
1210.2.2, 1210.2.3
BPVC—2004 Boiler & Pressure Vessel Code (Sections I, II, IV, V & VI, VIII & IX) 1003.3, 1004.1, 1011.1,1210.2.2, 1305.12.1
CSD-1—1998 Controls and Safety Devices for Automatically Fired Boilers
1004.1
ASNT American Society for Nondestructive Testing
3200 Riverside Drive
Columbus, Ohio 43221
Standard
reference
number
Title Referenced in
code section
number
SNT—TC—1A—1980 Recommended Practice 1210.2.2
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced in
code section
number
A 53/A 53M—01 Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded
   and Seamless
Table 1202.4, Table 1302.3, 1305.9
A106—99el Specification for Seamless Carbon Steel Pipe for
   High-Temperature Service.
Table 1202.4, Table 1302.3, 1305.9
A 126—01 Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fittings Table 1202.5
A 254—97 Specification for Copper Brazed Steel Tubing
Table 1202.4
A 420/A 420M—01 Specification for Piping Fittings of Wrought Carbon Steel and
   Alloy Steel for Low-Temperature Service. .
Table1202.5
A 539—99 Specification for Electric-Resistance-Welded Coiled Steel
   Tubing for Gas and Fuel Oil Lines
Table 1302.3
B 32—00 Specification for Solder Metal 1203.3.3
B 42—98 Specification for Seamless Copper Pipe, Standard Sizes 513.13.1, 1107.4.2, Table 1202.4, Table 1302.3
B 43—98 Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1, 1107.4.2, Table 1202.4, Table 1302.3
B 68—99 Specification for Seamless Copper Tube, Bright Annealed 513.13.1
B 75—99 Specification for Seamless Copper Tube
Table 1202.4, Table 1302.3
B 88—99el Specification for Seamless Copper Water Tube 513.13.1, 1107.4.3, Table 1202.4, Table 1302.3
B 135—00 Specification for Seamless Brass Tube Table 1202.4
B 251—97 Specification for General Requirements for Wrought Seamless
   Copper and Copper-Alloy Tube
513.13.1, Table 1202.4
B 280—99el Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
513.13.1, 1107.4.3, Table 1302.3
B 302—00 Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4, Table 1302.3
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube
1203.3.3
C 315—00 Specification for Clay Flue Linings 801.16.1, Table 803.10.4
C 411—97 Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation
604.3
D 56—01 Test Method for Flash Point by Tag Closed Tester
202
D 93—00 Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe,Schedules 40 and 80 Table 1202.4
D 1693—01 Test Method for Environmental Stress-Cracking of Ethylene Plastics Table 1202.4
D 1785—99 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules
   40, 80 and 120
Table 1202.4
D 2235—01 Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene
   (ABS) Plastic Pipe and Fittings. .
1203.3.4
D 2241—01 Specification for Poly (Vinyl Chloride)(PVC) Pressure-RatedPipe (SDR-Series) Table 1202.4
D 2282—99 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 1202.4
D 2412—96a Test Method for Determination of External Loading Characteristics of
   Plastic Pipe by Parallel-Plate Loading.
603.8.3
D 2447—99 Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80,
   Based on Outside Diameter
Table 1202.4
D 2466—01 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40
Table 1202.5
D 2467—01 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80
Table 1202.5
D 2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2513—00 Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings Table 1202.4, 1203.15.3
D 2564—96a Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 1203.3.4
D 2683—98 Specification for Socket-Type Polyethylene Fittings for Outside
   Diameter-Controlled Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.1
D 2837—98a Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials Table 1202.4
D 2846/D 2846M—99 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic
   Hot and Cold Water Distribution Systems
Table 1202.4, 1203.3.4
D 2996—00 Specification for Filament-Wound Fiberglass
   (Glass Fiber Reinforced Thermosetting Resin) Pipe
Table 1302.3
D 3035—01 Specification for Polyethylene (PE) Plastic Pipe (DR-PR)
   Based on Controlled Outside Diameter
Table 1202.4
D 3278—96el Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus 202
D 3309—96a Specification for Polybutylene (PB) Plastic Hot-and Cold-Water Distribution Systems Table 1202.4, 1203.10.1
D 3350—01 Specification for Polyethylene Plastics Pipe and Fittings Materials
Table 1202.4
E 84—01 Test Method for Surface Burning Characteristics of Building Materials
202, 510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
E 119—00e Test Method for Fire Tests of Building Construction and Materials
607.5.2, 607.5.5.1, 607.6.1, 607.6.2
E 136—99e01 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
202
E 814—00 Test Method for Fire Tests of Through-Penetration Fire Stops 506.3.10
F 438—01 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
   Plastic Pipe Fittings, Schedule 40
Table 1202.5
F 439—01 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
   Plastic Pipe Fittings, Schedule 80
Table 1202.5
F 441/F 441M—99 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
   Plastic Pipe, Schedules 40 and 80.
Table 1202.4
F 442/F 442M—99 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Table 1202.4
F 493—97 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride)
   (CPVC) Plastic Pipe and Fittings
1203.3.4
F 876—01 Specification for Crosslinked Polyethylene (PEX) Tubing Table 1202.4
F 877—01 Specification for Crosslinked Polyethylene (PEX) Plastic Hot and
   Cold-Water Distribution Systems
Table 1202.4, Table 1202.5
F 1055—98 Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled
   Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.2
F 1281—01 Specification for Crosslinked Polyethylene/Aluminum/Crosslinked
   Polyethylene (PEX-AL-PEX) Pressure Pipe
Table 1202.4
F 1974—00e Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/
   Polyethylene and Crosslinked Polyethylene Aluminum/Crosslinked Polyethylene
   Composite Pressure Pipe.
Table 1202.5
AWS American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
Standard
reference
number
Title
Referenced in
code section
number
A5.8—92 Specifications for Filler Metals for Brazing and Braze Welding 1203.3.1, 1303.3.1
CSA Canadian Standards Association
178 Rexdale Blvd.
Rexdale (Toronto), Ontario, Canada M9W 1R3
Standard
reference
number
Title Referenced in
code section
number
CAN/CSA b137.10M—99 Crosslinked Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems Table 1202.4
DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced in
code section
number
29 CFR Part 1910.1000 (1974) Air Contaminants 502.6
IIAR International Institute of Ammonia Refrigeration
Suite 7001101 Connecticut Ave., NW
Washington, DC 20036
Standard
reference
number
Title Referenced in
code section
number
2—99 Equipment, Design, and Installation of Ammonia Mechanical Refrigeration Systems 1101.6
MSS Manufactures Standardization Society of the Valve and Fittings Industry, Inc.
127 Park Street, Northeast
Vienna, VA 22180 MSS
Standard
reference
number
Title Referenced in
code section
number
SP-69—1996 Pipe Hangers and Supports—Selection and Application 305.4
NAIMA
Standard
reference
number
Title Referenced in
code section
number
AH116—02 Fibrous Glass Duct Construction Standards 603.5, 603.9
NFPA National Fire Protection Association
1 Batterymarch Pike
P.O. Box 9101
Quincy, MA 02269-9101
Standard
reference
number
Title Referenced in
code section
number
*30—03 Flammable Combustible Code 605.4, 1305.8
31—01 Installation of Oil-Burning Equipment 801.2.1, 801.18.1, 801.18.2,
901.2, 918.1, 920.2,
922.1, 1301.2, 1305.11, 1308.1
37—98 Stationary Combustion Engines and Gas Turbines 811.1, 811.2, 915.1, 915.2
45—04 Fire Protection for Laboratories Using Chemicals Table 403.3, 407.1, 502.20
54—06 National Fuel Gas Code 901.2, 910.7, 918.2
58—01 Liquefied Petroleum Gas Code 502.9.10
69—97 Explosion Prevention Systems 510.8.3
70—02 National Electrical Code 1104.2.2
82—99 Incinerators and Waste and Linen Handling Systems and Equipment 601.1, 907.1
88B—97 Repair Garages 304.5
91—99 Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and
   Noncombustible Particulate Solids
502.9.5.1, 502.17
96—84 Installation of Equipment for the Removal of Smoke and Grease-laden Vapors from
   Commercial Cooking Equipment
506.3.7.1
211—00 Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances 802.1, Table 803.10.6, 806.1, 811.1, 901.2
262—99 Standard Method of Test for Flame Travel and Smoke of Wires
   and Cables for Use in Air-Handling Spaces
602.2.1.1
704—96 Identification of the Hazards of Materials for Emergency Response 502.8.4, 510.1, Table 1103.1, 1105.10
853—00 Installation of Stationary Fuel Power Plants 924.1
8501—97 Single Burner Boiler Operation 1004.1
8502—99 Prevention of Furnace Explosions/Implosions in Multiple Burner Boiler-Furnaces 1004.1
8504—96 Atmospheric Fluidized-Bed Boiler Operation 1004.1
*Section MC 1502was amended by: 1 RCNY 7000-01. This law has an effective date of October 31, 2009.
NYC/NYS New York City Codes / New York State Codes / NYC Agencies
Standard
reference
number
Title Referenced in
code section
number
Energy Conservation Construction Code of New York State 202, 301.2, 303.3312.1, 514.1, 603.9, 604.1, 905.4, 1204.1, 1204.2
New York City Air Pollution Code 801.5, 811.2.2, 904.1, 905.3, 907.2
New York City Building Code based on 2003 IBC 106.4, 106.5, 107.1 201.3, 301.12, 301.12,301.14, 301.15, 302.1, 302.2, 304.7, 304.10, 308.8,308.10, 401.4, 401.6, 402.1, 405.2.1, 406.1, 502.10, 502.10.1, 502.16.2, 504.2, 506.3.3, 506.3.10, 506.3.12.2, 506.4.1, 509.1, 510.6, 510.6.1, 510.6.2, 510.7, 511.1.5, 512.2, 513.1, 513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.2.1, 513.6.2, 513.10.5, 513.12,513.12.2, 513.12.3, 513.20, 513.20.2, 601.2, 602.2.1.5.1, 602.2.1.5.2, 602.3, 603.1, 603.6.1.1, 603.10, 603.15, 607.1.1, 607.3.2.1, 607.5.1, 607.5.2, 607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.5.5.1, 607.6, 701.4.1, 701.4.2, 801.3, 801.16.1, 801.18.4, 901.5, 902.1, 908.3, 908.3.2, 908.4, 910.3, 925.1, 1004.6, 1104.2.2, 1105.1, 1206.4, 1206.10, 1402.4, 1402.4.1
New York City Electrical Code based on 2002 NEC 201.3, 301.7, 306.3.1, 306.4.1, 513.11, 513.12.1, 602.2.1.1, 606.3, 1305.11.1.1
New York City Fire Code 201.3, 310.1, 311.1, 502.5,502.7.2, 502.8.1,502.9.5, 502.9.5.2, 502.9.5.3, 502.9.8.2, 502.9.8.3,502.9.8.5, 502.9.8.6, 502.7, 502.8, 502.9, 502.9.10, 502.10, 502.10.3, , 509.1, 510.2.1, 510.2.2, 510.4, 513.15, 513.16,513.17, 513.18, 513.19, , 513.20.3,515.1, 606.2.1, 908.7,1101.9, 1105.7.2, 1109.2, 1301.1,
New York City Fuel Gas Code based on 2003 IFGC 101.2, 201.3,301.3, 701.1, 801.1,801.2.2, 807.1, 901.1, 906.1, 917.6, 1101.5
New York City Fuel Oil Tank Construction Standards 1301.2, 1305.11
New York City Plumbing Code based on 2003 IPC 201.3, 301.8, 512.2, 908.5, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1401.2
New York State Department of Environmental Conservation Petroleum
   Bulk Storage Code (6 NYCRR-612, 613, 614)
1301.2
New York State Department of Labor Industrial Code Rule Part 4 1003.3,1004.1
New York State Department of Labor Industrial Code Rule Part 4-6.2 1003.3
New York State Department of Labor Industrial Code Rule Part 14 1003.3, 1004.1
United States Environmental Protective Agency Technical Requirements
   and Corrective Action Requirements for Owners and Operators of Underground
   Storage Tanks 40 CFR Part 280
1301.6
SMACNA Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4021 Fafayette Center Road
Chantilly, VA 22021
Standard
reference
number
Title Referenced in
code section
number
SMACNA—95 HVAC Duct Construction Standards—Metal and Flexible 603.4, 603.9
SMACNA—92 Fibrous Glass Duct Construction Standards 603.5, 603.9
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced in
code section
number
17—94 Vent or Chimney Connector Dampers for Oil-Fired Appliances—with Revisions
   through September 1998
803.6
58—96 Steel Underground Tanks for Flammable and Combustible Liquids 1305.12.1
80—04 Steel Tanks for Oil-Burner Fuel 1305.12.1, Table 1305.7(2)
103—98 Factory-Built Chimneys, Residential Type and Building Heating Appliance—with
   Revisions through March 1999
805.2
127—96 Factory-Built Fireplaces—with Revisions through November 1999 805.3, 903.1
142—02 Aboveground Tanks for Flammable and Combustible Liquids 1305.8, 1305.12.1
174—98 Household Electric Storage Tank Water Heaters—with revisions through October 1999 1002.1
181—96 Factory-made Air Ducts and Air Connectors—with Revisions
   through December 1998
512.2, 603.5, 603.6.1.1, 603.6.2, 603.11.1, 604.13
197—93 Commercial Electric Cooking Appliances—With Revisions Through January 2000 507.1
207—93 Refrigerant-Containing Components and Accessories,
   Nonelectrical—with Revisions Through October 1997
1101.2
343—97 Pumps for Oil-Burning Appliances-with revisions through December 22, 1999 1302.7
391—95 Solid-Fuel and Combination-Fuel Central and Supplementary
   Furnaces—with Revisions Through May 1999
918.1
412—93 Refrigeration Unit Coolers—with Revisions through November 1998 1101.2
471—95 Commercial Refrigerators and Freezers—with Revisions through April 1998 1101.2
536—97 Flexible metallic Hose -with revisions through October 2000 1302.8
555—99 Fire Dampers -with Revisions through October, 2000 607.3
555C—96 Ceiling Dampers 607.3, 607.6.2
555S—99 Smoke Dampers—with Revisions through December 1999 607.2.1.1, 607.3, 607.3.1.1
586—96 High-Efficiency, Particulate, Air Filter Units -with revisions through April 21, 2000 605.2
641—95 Type L Low-Temperature Venting Systems—with Revisions through April 1999 802.1
710—95 Exhaust Hoods for Commercial Cooking Equipment-with Revisions through April 1999 507.1
726—98 Oil-Fired Boiler Assemblies—with Revisions through January 1999 916.1, 1004.1
727—94 Oil-Fired Central Furnaces—with Revisions through January 1999 918.1
729—98 Oil-Fired Floor Furnaces—with Revisions through January 1999 910.1
730—98 Oil-Fired Wall Furnaces—with Revisions through January 1999 909.1
731—95 Oil-Fired Unit Heaters—with Revisions through January 1999 920.1
732—95 Oil-Fired Storage Tank Water Heaters-With revisions through January 1999 1002.1
737—96 Fireplace Stoves—with Revisions through January 2000 805.2, 905.1
762—99 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances 506.5.1
791—93 Residential Incinerators—with Revisions through May 1998 907.1
834—98 Heating, Water Supply and Power Boilers Electric—with Revisions Through November 1998 1004.1
864—03 Control Units and Accessories for Fire Alarm Systems 513.12
867—00 Electrostatic Air Cleaners 605.2
896—93 Oil-Burning Stoves—with Revisions through November 1999 917.1, 922.1
900—94 Air Filter Units -with revisions through October 1999 605.2, 607.2.3
959—01 Medium Heat Appliance Factory-Built Chimneys 805.5
1046—00 Grease Filters for Exhaust Ducts 507.11
1240—94 Electric Commercial Clothes Drying Equipment—with Revisions through October 1999 913.1
1261—96 Electric Water Heaters for Pools and Tubs -with revisions through November 25, 1998 916.1
1316—94 Glass-Fiber Reinforced Plastic Underground Storage Tanks for
   Petroleum Products, Alcohols, and Alcohol-Gasoline Mixtures
1305.12.1
1453—95 Electronic Booster and Commercial Storage Tank Water Heaters
   with Revisions Through September 1998
1002.1
1482—98 Solid-Fuel Type Room Heaters—with Revisions through January 2000 905.1
1777—98 Chimney Liners—with Revisions through July 1998 801.18.4, 806.16.1
1820—97 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics —
   with Revisions through March 1999
602.2.1.3
1887—96 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—
   with Revisions through June 1999
602.2.1.2
1995—98 Heating and Cooling Equipment -with Revisions through August 1999 911.1, 918.1, 918.3, 1101.2
2043—96 Fire Test for Heat and Visible Smoke Release for Discrete Products and
their Accessories Installed in Air-Handling Spaces-With Revisions through February 1998
602.2.1.4
2158—97 Outline of Investigation Electric Clothes Dryer—with Revisions through February 1999 913.1
2162—94 Outline of Investigation for Commercial Wood-Fired Baking Ovens—Refractory Type 917.1