Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard.
Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to these standards in accordance with Section 28-103.19 of the Administrative Code.
The application of the referenced standards shall be as specified in Section 102.8.
ACCA Air Conditioning Contractors of America
1712 New Hampshire Ave, NW
Washington, DC 20009
Standard
reference
number
Title Referenced
in code
section number
Manual D—95 Residential Duct Systems 603.2

AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
Title Referenced
in code
section number
550—09 Test Method for High Velocity Wind Driven Rain Resistant Louvers 401.6.1, 501.2.2.1

ANSI American National Standards Institute
11 West 42nd Street
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASHRAE/
ASHE 170—2008
Ventilation of Health Care Facilities 401.4
ANSI/ASSE 1017—2003 Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distributions Systems 1002.2.2
Z21.8—1994 (R2002) Installation of Domestic Gas Conversion Burners 919.1
Z21.50—2003 Vented Gas Fireplaces 901.6
Z21.60—2003 Decorative Gas Appliances for Installation in Solid—Fuel Burning Fireplaces 901.6
Z21.83—1998 Fuel Cell Power Plants 924.1


ARI Air-Conditioning and Refrigeration Institute
4301 North Fairfax Drive, Suite 425
Arlington, VA 22203
Standard
reference
number
Title Referenced
in code
section number
700—99 Purity Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3


ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2005 ASHRAE Fundamentals Handbook—2005 312.1, 603.2
15—2010 Safety Standard for Refrigeration Systems 1101.6, 1101.11, 1104.2, 1105.3, 1105.8, 1105.11, 1108.1
34—2010 Designation and Safety Classification of Refrigerants 202, 1102.2.1, 1103.1, Table 1103.1, 1104.1
ASHRAE—2000 HVAC Systems and Equipment Handbook—2000 312.1
52.2—2012 Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size 605.2.1
62.1 —2007 Ventilation for Acceptable Indoor Air Quality 403.3.2.3.2, 605.2.1
62.2—2010 Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings 605.2.1


ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—2006 Malleable Iron Threaded Fittings, Classes 150 & 300 Table 1202.5
B16.5—2003 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24 Table 1202.5
B16.9—2003 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—2005 Forged Fittings, Socket-Welding and Threaded Table 1202.5
B16.15—2006 Cast Bronze Threaded Fittings Table 1202.5
B16.18—2001
(Reaffirmed 2005)
Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—2001
(Reaffirmed 2005)
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings—with B16.22a—1998 Addenda 513.13.1, Table 1202.5
B16.23—2002
(Reaffirmed 2006)
Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 1202.5
B16.24—2001 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500 Table 1202.5
B16.26—2006 Cast Copper Alloy Fittings for Flared Copper Tubes Table 1202.5
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 1202.5
B16.29—2001 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV Table 1202.5
B16.39—1986 (R1998) Malleable Iron Threaded Pipe Unions 1203.1.2
B31.1—2012 Power Piping Code 1201.3, 1210.2.1, 1210.2.2, 1210.2.3
B31.9—2004 Building Services Piping 1201.3
B40.100—2005 Pressure Gauges and Gauge Attachments 1011.2
BPVC—2010 Boiler & Pressure Vessel Code 1002.2, 1003.1, 1003.2, 1003.3, 1004.1, 1004.1.1, 1011.1, 1107.5.4,
1203.3.1, 1203.3.6, 1210.2.2, 1303.1, 1303.3.1, 1303.3.4, 1305.12.2, 1305.14
CSD—1-2004 Controls and Safety Devices for Automatically Fired Boilers 1004.1, 1004.1.1, 1007.2. 1011.1


ASNT American Society for Nondestructive Testing
PO Box 28518
1711 Arlington Lane
Columbus, OH 43228
Standard
reference
number
Title Referenced
in code
section number
SNT-TC-1A—1980 Recommended Practice 1210.2.2

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—06a Specification for Pipe, Steel, Black and Hot—Dipped, Zinc-Coated
Welded and Seamless
Table 1202.4, Table 1302.3, 1305.9.5
A 106/A106M—06a Specification for Seamless Carbon Steel Pipe for High-Temperature Service Table 1202.4, Table 1302.3, 1305.9.5
A 126—04 Specification for Gray Iron Castings for Valves, Flanges, and Pipe Fitting Table 1202.5
A 254—97 (2002) Specification for Copper Brazed Steel Tubing Table 1202.4, Table 1302.3
A 420/A 420M—07 Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low—Temperature Service Table 1202.5
A 539—99 Specification for Electric—Resistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines Table 1302.3
B 32—04 Specification for Solder Metal. 1203.3.3, 1107.5.5
B 42—(02e01) Specification for Seamless Copper Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 43—98 (2004) Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 68—02 Specification for Seamless Copper Tube, Bright Annealed 513.13.1
B 75—02 Specification for Seamless Copper Tube Table 1202.4, Table 1302.3
B 88—03 Specification for Seamless Copper Water Tube 513.13.1, 1107.5.3, Table 1202.4, Table 1302.3
B 135—02 Specification for Seamless Brass Tube Table 1202.4
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube 513.13.1, Table 1202.4
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and
Refrigeration Field Service
513.13.1, 1107.5.3,Table 1302.3
B 302—02 Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4, Table 1302.3
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube 1203.3.3, 1107.5.5
C 315—07 Specification for Clay Flue Linings 801.16.1, Table 803.10.4
C 411—05 Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation 604.3
D 56—05 Test Method for Flash Point by Tag Closed Tester 202
D 93—07 Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99 (2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 1202.4
D 1693—07 Test Method for Environmental Stress-Cracking of Ethylene Plastics Table 1202.4
D 1785—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 1202.4
D 2235—04 Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings 1203.3.4
D 2241—05 Specification for Poly (Vinyl Chloride)(PVC) Pressure-Rated Pipe (SDR-Series) Table 1202.4
D 2282—99 (2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 1202.4
D 2412—02 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading 603.8.3
D 2447—03 Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter Table 1202.4
D 2466—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2467—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80 Table 1202.5
D 2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2513—07a Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings Table 1202.4
D 2564—04e01 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 1203.3.4
D 2657—07 Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings 1203.15.1
D 2683—04 Specification for Socket-Type Polyethylene Fittings for Outside Diameter-Controlled
Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.1
D 2837—04e01 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials Table 1202.4
D 2846/D 2846M—06 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems Table 1202.4
D 2996—07 (2007)e01 Specification for Filament-Wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe Table 1302.3
D 3035—06 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter Table 1202.4
D 3261—03 Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings
for Polyethylene (PE) Plastic Pipe and Tubing
1203.15.1
D 3278—96 (2004)e01 Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus 202
D 3350—06 Specification for Polyethylene Plastics Pipe and Fittings Materials Table 1202.4
E 84—07 Test Method for Surface Burning Characteristics of Building Materials 202, 510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
E 119—07 Test Method for Fire Tests of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1, 607.6.2, 607.6.2.1
E 136—04 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 202
E 814—06 Test Method for Fire Tests of Through-Penetration Fire Stops 506.3.10.1, 506.3.10.2, 506.3.10.3
E 1509—04 Specification for Room Heaters, Pellet Fuel-burning Type 904.1
E 2231—04 Standard Practice For Specimen Preparation and Mounting of Pipe and Duct
Insulation Materials to Assess Surface Burning Characteristics
604.3, 1204.1
E 2236—04 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems 506.3.10.2
F 438—04 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 Table 1202.5
F 439—06 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Table 1202.5
F 441/F 441M—02 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Table 1202.4
F 442/F 442M—(2005) Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR Table 1202.4
F 492—95 Specification for Propylene and Polypropylene (PP) Plastic-Lined Ferrous Metal Pipe and Fittings 1203.1.2
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings 1203.3.4
F 876—06 Specification for Crosslinked Polyethylene (PEX) Tubing Table 1202.4
F 877—07 Specification for Crosslinked Polyethylene (PEX) Plastic Hot and
Cold-Water Distribution Systems
Table 1202.4, Table 1202.5
F 1055—98 (2006) Specification for Electrofusion Type Polyethylene Fittings for Outside
Diameter Controlled Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.2
F 1281—07 Specification for Crosslinked Polyethylene/Aluminum/Crosslinked
Polyethylene (PEX-AL-PEX) Pressure Pipe
Table 1202.4
F 1282—06 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Table 1202.4
F 1476—07 Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications 1203.3.7
F 1924—05 Standard Specification for Plastic Mechanical Fittings for Use on Outside
Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing
1203.15.3
F 1974—04 Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe
Table 1202.5
F 2389—06 Specification for Pressure-Rated Polypropylene Piping Systems Table 1202.4, 1203.16.1
F 2623—07 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing 1 Table 1202.4

AWWA American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C110/A21.10—03 Standard for Ductile Iron & Gray Iron Fittings, 2 inches through 48 inches for Water Table 1202.5
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges Table 1202.4
C151/A21.51—02 Standard for Ductile-Iron Pipe, Centrifugally Cast for Water Table 1202.4
C153/A21.53—00 Standard for Ductile-Iron Compact Fittings for Water Service Table 1202.5

AWS American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
Standard
reference
number
Title Referenced
in code
section number
B2.1—2009 Specification for Brazing Procedure and Performance Qualification 1203.3.6
B2.2—2010 Specification for Brazing Procedure and Performance Qualification 1203.3.1, 1303.1, 1303.3.1, 1107.5.4

CAN/ULC Standards Council of Canada
270 Albert Street, Suite 200
Ottawa ON KIP 6N7
Canada
Standard
reference
number
Title Referenced
in code
section number
S635—00 Standard for Lining Systems for Existing Masonry or Factory-Built Chimneys and Vents 801.16.1, 801.18.4
S640—91 Standard for Lining Systems for New Masonry Chimneys 801.16.1

CSA Canadian Standards Association
178 Rexdale Blvd.
Rexdale (Toronto), Ontario, Canada M9W 1R3
Standard
reference
number
Title Referenced
in code
section number
CAN/CSA B137.10—02 Crosslinked Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems Table 1202.4
B137.9—M91 CAN/CSA Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems Table 1202.4

DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000 (1974) Air Contaminants 502.6

IIAR International Institute of Ammonia Refrigeration
1101 Connecticut Ave., NW, Suite 700
Washington, DC 20036
Standard
reference
number
Title Referenced
in code
section number
2—99
(with Addendum A—2005)
Addendum A to Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems 1101.6

MSS Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
Standard
reference
number
Title Referenced
in code
section number
SP-69—2002 Pipe Hangers and Supports—Selection and Application. 305.4

NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
AH116—02 Fibrous Glass Duct Construction Standard 603.5, 603.9

NFPA National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
Standard
reference
number
Title Referenced
in code
section number
10—07 Portable Fire Extinguishers 1301.8
30—00 Flammable and Combustible Liquids Code 605.4,1305.8.3, 1305.8.4, 1308.1
30A—03 Code for Motor Fuel Dispensing Facilities and Repair Garages 304.6
31—11 Installation of Oil-Burning Equipment 801.2.4, 801.18.1, 801.18.2, 901.2,
918.1, 920.2, 1301.2, 1308.1
32—11 Standard for Drycleaning Plants 502.6
37—10 Stationary Combustion Engines and Gas Turbines 811.1, 811.2, 915.1, 915.2
45—04 Fire Protection for Laboratories Using Chemicals 407.1, 502.20
54—06 National Fuel Gas Code 901.2, 910.7, 918.2
69—08 Explosion Prevention Systems 510.8.3
70—02 National Electrical Code 511.1.1
72—07 National Fire Alarm Code 513.12
82—04 Incinerators and Waste and Linen Handling Systems and Equipment 601.1, 907.1
85—11 Boiler and Combustion Systems Hazards Code 1004.1, 1004.1.1
92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 513.8
96—84 Installation of Equipment for the Removal of Smoke and Grease-laden Vapors from
Commercial Cooking Equipment
506.3.7.1
211—10 Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances 802.1, Table 803.10.6, 806.1, 811.1, 901.2
262—07 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for
Use in Air-Handling Spaces
602.2.1.1
704—07 Identification of the Hazards of Materials for Emergency Response 502.8.4, 510.1, 1105.11
853—07 Installation of Stationary Fuel Power Plants 924.1

SMACNA Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4021 Fafayette Center Road
Chantilly, VA 22021
Standard
reference
number
Title Referenced
in code
section number
SMACNA/ANSI—2005 HVAC Duct Construction Standards—Metal and Flexible (2005) 504.8, 603.4, 603.9
SMACNA—03 Fibrous Glass Duct Construction Standards 603.5

UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
17—94 Vent or Chimney Connector Dampers for Oil-Fired Appliances—with Revisions through September 1998 803.6
58—96 Steel Underground Tanks for Flammable and Combustible Liquids 1305.12.1, 1305.14
80—04 Steel Tanks for Oil-Burner Fuel Table 1305.7(2), 1305.12.2, 1305.14
103—01 Factory-Built Chimneys, Residential Type and Building Heating Appliance—with Revisions through March 1999 805.2
127—96 Factory-Built Fireplaces—with Revisions through November 1999 805.3, 903.1
142—02 Aboveground Tanks for Flammable and Combustable Liquids Table 1305.7(2), 1305.8.1, 1305.12.2, 1305.14
174—04 Household Electric Storage Tank Water Heaters—with revisions through May 2006 1002.1
181—05 Factory-made Air Ducts and Air Connectors—with Revisions
through December 1998
512.2, 603.5, 603.6.1.1, 603.6.2, 603.11.1, 604.13
181A—05 Closure Systems for Use with Rigid Air Ducts and Air Connectors—with Revisions through December 1998 603.9
181B—05 Closure Systems for Use with Flexible Air Ducts and Air Connectors—with Revisions through December 1998 603.9
197—93 Commercial Electric Cooking Appliances—with Revisions Through January 2000 917.1
207—01 Refrigerant-Containing Components and Accessories, Nonelectrica—with Revisions Through November 2004 1101.2
263—03 Standard for Fire Test of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1, 607.6.2
268—06 Smoke Detectors for Fire Prevention Signaling Systems—with Revisions through October 2003 606.1
268A—98 Smoke Detectors for Duct Applications—with Revisions through April 2006 606.1
343—97 Pumps for Oil-Burning Appliances—with revisions through December 22, 1999 1302.7
391—2006 Solid-Fuel and Combination-Fuel Central and Supplementary Furnaces 918.1
412—04 Refrigeration Unit Coolers—with Revisions through February 2007 1101.2
471—06 Commercial Refrigerators and Freezers—with Revisions through March 2006 1101.2
536—97 Flexible metallic Hose—with revisions through October 2000 1302.8
555—06 Fire Dampers—with Revisions through January 2002 607.3, 607.3.1
555C—06 Ceiling Dampers 607.3.1, 607.6.2
555S—99 Smoke Dampers—with Revisions through July 2006 607.2.1.1, 607.3, 607.3.1, 607.3.1.1
586—96 High-Efficiency, Particulate, Air Filter Units—with Revisions through August 2004 605.2
641—95 Type L Low-Temperature Venting Systems—with Revisions through April 1999 802.1
710—95 Exhaust Hoods for Commercial Cooking Equipment—with Revisions through February 2007 507.1
710B—04 Recirculating Systems 507.1
723—03 Standard for Test for Surface Burning Characteristics of
Building Materials—with Revisions through May 2005
202, 510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
726—95 Oil-Fired Boiler Assemblies—with Revisions through March 2006 916.1, 1004.1, 1004.1.1
727—06 Oil-Fired Centeral Furnaces 918.1
729—03 Oil-Fired Floor Furnaces—with Revisions through January 1999 910.1
730—03 Oil-Fired Wall Furnaces—with Revisions through January 1999 909.1
731—95 Oil-Fired Unit Heaters—with Revisions through February 2006 920.1
732—95 Oil-Fired Storage Tank Water Heaters—with Revisions through February 2005 1002.1
737—96 Fireplace Stoves—with Revisions through January 2000 905.1
762—03 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances 506.5.1
791—06 Residential Incinerators 907.1
795—05 Commercial-Industrial Gas Heating Equipment 1004.1.1
834—04 Heating, Water Supply and Power Boilers Electric—with Revisions Through March 2006 1004.1
858—05 Household Electric Ranges—with Revisions through January 1999 917.1
864—03 Control Units and Accessories for Fire Alarm Systems 513.12
867—00 Electrostatic Air Cleaners 605.2
875—04 Electric Dry Bath Heater—with Revisions through March 2006 914.2
896—93 Oil-Burning Stoves—with Revisions through November 1999 917.1
900—04 Air Filter Units 605.2
923—02 Microwave Cooking Appliances—with Revisions through February 2006 917.1
959—01 Medium Heat Appliance Factory-Built Chimneys 805.5
1046—00 Grease Filters for Exhaust Ducts 507.11
1240—05 Electric Commercial Clothes Drying Equipment 913.1
1261—01 Electric Water Heaters for Pools and Tubs—with Revisions through November 25, 1998 916.1
13 16—94 Glass-Fiber Reinforced Plastic Underground Storage Tanks for
Petroleum Products, Alcohols, and Alcohol-Gasoline Mixtures
1305.12.1, 1305.14
1453—06 Electronic Booster and Commercial Storage Tank Water
Heaters—with Revisions through May 2006
1002.1
1479—06 Fire Tests of Through-Penetration Firestops 506.3.10.3
1482—96 Solid-Fuel Type Room Heaters—with Revisions through November 2006 905.1
1777—04 Chimney Liners—with Revisions through July 1998 801.16.1, 801.18.4
1812—05 Standard for Ducted Heat Recovery Ventilators—with Revisions through January 2006 927.1
1815—01 Standard for Nonducted Heat Recovery Ventilators—with Revisions through January 2006 927.2
1820—04 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics 602.2.1.3
1887—04 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics 602.2.1.2
1978—95 Grease Ducts 506.3.1.1, 506.3.2, 506.3.6
1995—05 Heating and Cooling Equipment 911.1, 918.1, 918.3, 1101.2
2043—96 Fire Test for Heat and Visible Smoke Release for Discrete Products
and their Accessories Installed in Air-Handling Spaces—with Revisions through February 1998
602.2.1.4
2106—09 Standard for Field Erected Boiler Assemblies 1004.1.1
2158—97 Outline of Investigation Electric Clothes Dryer—with Revisions through May 2004 913.1
2185A—06 Clothes Dryer Transition Duct 504.6.3
2162—01 Outline of Investigation for Commercial Wood-Fired Baking Ovens-Refractory Type 917.1
2200—04 Stationary Engine Generator Assemblies 915.1, 1302.6