[BE] 1004.5 Outdoor Areas
JUMP TO FULL CODE CHAPTER
Yards, patios, courts and similar outdoor areas accessible to and usable by the building occupants shall be provided with means of egress as required by this chapter. The occupant load of such outdoor areas shall be assigned by the fire code official in accordance with the anticipated use. Where outdoor areas are to be used by persons in addition to the occupants of the building, and the path of egress travel from the outdoor areas passes through the building, means of egress requirements for the building shall be based on the sum of the occupant loads of the building plus the outdoor areas.
Exceptions:
- Outdoor areas used exclusively for service of the building need only have one means of egress.
- Both outdoor areas associated with Group R-3 and individual dwelling units of Group R-2.
Related Code Sections
1004.5 Means of Egress, Outdoor Areas
Yards, patios, courts and similar outdoor areas accessible to and usable by the building occupants shall be provided with means of egress as required ...
1004.5 Means of Egress, Outdoor Areas
Yards, patios, courts and similar outdoor areas accessible to and usable by the building occupants shall be provided with means of egress as required ...
1004.7 Means of Egress, Outdoor Areas
Yards , patios, occupied roofs, courts and similar outdoor areas accessible to and usable by the building occupants shall be provided with means ...
1225.5.2.5.2 Interior Environment, Outdoor Area
Outdoor area(s) shall be provided for the use of all patients and shall include walking paths of durable materials, benches, shaded areas, and visual ...
Los Angeles Building Code > 12 Interior Environment > 1225 [OSHPD 2] Skilled Nursing and Intermediate-Care Facilities > 1225.5 Skilled Nursing Unit Models > 1225.5.2 Household Model > 1225.5.2.5 Resident Living Area > 1225.5.2.5.2 Outdoor Area
1228.30.3.2 Interior Environment, Outdoor Areas
Pediatric and adolescent
outdoor areas shall be separate from adult outdoor
areas. Refer to Section 1228.13.1.2 ...