Heads up: There are no amended sections in this chapter.

User note:

About this chapter: This code contains numerous references to standards that are used to provide requirements for materials and methods of construction. This chapter contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.This chapter lists the standards that are referenced in various sections of this document.

The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206

ANSI/ACCA 1 Manual D---2016

Residential Duct Systems

601.4, 603.2

ANSI/ASHRAE/ACCA 183—2007 (reaffirmed 2014)

Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings

312.1

AHRI

Air-Conditioning, Heating & Refrigeration Institute
2111 Wilson Blvd., Suite 500
Arlington VA22201

700—2015

with Addendum 1: Specifications for Refrigerants

1102.2.2.3

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL 60004

230-15

Laboratory Methods of Testing Air Circulating Fans for Rating and Certification

929.1

550—09

Test Method for High Velocity Wind Driven Rain Resistant Louvers

401.5, 501.3.2

ANSI/AMCA 210—ANSI/ASHRAE 51—07

Laboratory Methods of Testing Fans for Aerodynamic Performance Rating

403.3.2.4

ANSI

American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY 10036

Z21.1—2010

Household Cooking Gas Appliances

505.2

Z21.8—1994 (R2002)

Installation of Domestic Gas Conversion Burners

919.1

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

ANSI/AMCA 210—ANSI/ASHRAE 51—07

Laboratory Methods of Testing Fans for Aerodynamic Performance Rating

403.3.2.4

ASHRAE—2017

ASHRAE Fundamentals Handbook

603.2

15—2016

Safety Standard for Refrigeration Systems

1101.6, 1105.8, 1108.1

34—2016

Designation and Safety Classification of Refrigerants

202, 1102.2.1, 1103.1

62.1—2016

Ventilation for Acceptable Indoor Air Quality

403.3.1.1.2.3.2

170—2017

Ventilation of Health Care Facilities

407

180—2012

Standard Practice for Inspection and Maintenance of Commercial Building HVAC Systems

102.3

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990

A112.4.1—2009

Water Heater Relief Valve Drain Tubes

1006.6

B1.20.1—2013

Pipe Threads, General Purpose (Inch)

1203.3.5, 1303.3.3

B16.3—2016

Malleable Iron Threaded Fittings, Classes 150 & 300

Table 1202.5

B16.5—2015

Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24

Table 1202.5

B16.9—2012

Factory Made Wrought Steel Buttwelding Fittings

Table 1202.5

B16.11—2016

Forged Fittings, Socket-welding and Threaded

Table 1202.5

B16.15—2013

Cast Alloy Threaded Fittings: Classes 125 and 250

Table 1202.5

B16.18—2012

Cast Copper Alloy Solder Joint Pressure Fittings

513.13.1, Table 1202.5

B16.22—2013

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

513.13.1, Table 1202.5

B16.24—2016

Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500

Table 1202.5

B16.26—2016

Cast Copper Alloy Fittings for Flared Copper Tubes

Table 1202.5

B16.28—1994

Wrought Steel Buttwelding Short Radius Elbows and Returns

Table 1202.5

B16.51—2013

Copper and Copper Alloy Press-connect Pressure Fittings

Table 1202.5

B31.5—2016

Refrigeration Piping and Heat Transfer Components

1107.1

B31.9—2014

Building Services Piping

1201.3

BPVC—2015

ASME Boiler & Pressure Vessel Code—07 Edition

1009.2, 1003.1, 1004.1, 1011.1

CSD-1—2016

Controls and Safety Devices for Automatically Fired Boilers

1004.1

ASSE

American Society of Safety Engineers
520 N. Northwest Highway
Park Ridge IL 60068

ANSI/ASSE Z359.1—2016

Requirements for ANSI/ASSE Z359 Fall Protection Code

304.11

ASSE

ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena IL 60448

1017—2010

Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems

1002.2.2

1061—2015

Performance Requirements for Push Fit Fittings

Table 1202.5

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428

A53/A53M—12

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated, Welded and Seamless

Table 1202.4, Table 1202.5, Table 1302.3

A106/A106M—14

Specification for Seamless Carbon Steel Pipe for High-temperature Service

Table 1302.3, Table 1202.5, Table 1202.4, Table 1302.3

A126—04(2014)

Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings

Table 1202.5

A234/A234M—15

Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service

Table 1202.5

A254—12

Specification for Copper Brazed Steel Tubing

Table 1202.4, Table 1302.3

A395/A395M—99(2014)

Standard Specification for Ferritic Ductile Iron Pressure-retaining Castings for Use at Elevated Temperatures

Table 1202.5, Table 1302.3

A420/A420M—14

Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-temperature Service

Table 1202.5

A536—84(2014)

Standard Specification for Ductile Iron Castings

Table 1202.5

A539—99

Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines

Table 1302.3

B32—08(2014)

Specification for Solder Metal

1203.3.3

B42—15a

Specification for Seamless Copper Pipe, Standard Sizes

513.13.1, 1107.5.2, Table 1202.4, Table 1302.3

B43—15

Specification for Seamless Red Brass Pipe, Standard Sizes

513.13.1, 1107.5.2, Table 1202.4, Table 1302.3

B68/B58M—11

Specification for Seamless Copper Tube, Bright Annealed

513.13.1

B75/B75M—11

Specification for Seamless Copper Tube

Table 1302.3

B88—14

Specification for Seamless Copper Water Tube

513.13.1, 1107.5.3, Table 1202.4, Table 1302.3

B135—10

Specification for Seamless Brass Tube

Table 1202.4

B251—10

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

513.13.1, Table 1202.4

B280—13

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

513.13.1, 1107.5.3, Table 1302.3

B302—12

Specification for Threadless Copper Pipe, Standard Sizes

Table 1202.4, Table 1302.3

B813—10

Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube

1203.3.3

B819—00(R2011)

Standard Specification for Seamless Copper Tube for Medical Gas Systems

1107.5.3

B828—02(2010)

Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

1203.3.3

C315—07(2011)

Specification for Clay Flue Liners and Chimney Pots

801.16.1, Table 803.10.4

C411—11

Test Method for Hot-surface Performance of High-temperature Thermal Insulation

604.3

D56—05(2010)

Test Method for Flash Point by Tag Closed Cup Tester

202

D93—15

Test Method for Flash Point of Pensky-Martens Closed Cup Tester

202

D1527—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80

Table 1202.4

D1693—15

Test Method for Environmental Stress-cracking of Ethylene Plastics

Table 1202.4

D1785—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120

Table 1202.4, Table 1210.4

D2235—04(2011)

Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings

1203.3.4

D2241—15

Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)

Table 1202.4, Table 1210.4

D2282—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)

Table 1202.4

D2412—11

Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading

603.8.3

D2464—15

Standard Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1210.5

D2466—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5, Table 1210.5

D2467—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5, Table 1210.5

D2564—12

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

1203.3.4

D2657—07

Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings

Table 1210.5

D2683—14

Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing

Table 1210.5, 1210.6.6.1

D2737—12a

Standard Specification for Polyethylene (PE) Plastic Tubing

Table 1210.4

D2846/D2846M—14

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4, 1203.3.4, Table 1210.4

D2996—01(2007)e01

Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe

Table 1302.3

D3035—15

Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

Table 1210.4

D3261—12e1

Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing

Table 1210.5, 1210.6.6.1

D3278—96(2011)

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

D3309—96a(2002)

Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4

E84—2016

Standard Test Method for Surface Burning Characteristics of Building Materials

202, 510.9, 602.2, 602.2.1, 602.2.1.6, 602.2.1.7, 604.3, 1204.1

E119—2016

Test Method for Fire Tests of Building Construction and Materials

607.5.2, 607.5.5, 607.6.1, 607.2.1

E136—16

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C

202

E814—13a

Standard Test Method for Fire Tests of Penetration Firestop Systems

506.3.11.2, 506.3.11.3

E1509—12

Specification for Room Heaters, Pellet Fuel-burning Type

904.1

E2231—15

Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics

604.3, 1204.1

E2336—16

Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems

506.3.6, 506.3.11.2

F437—15

Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 1210.5

F438—15

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5, Table 1210.5

F439—13

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5, Table 1210.5

F441/F441M—15

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80

Table 1202.4, Table 1210.4

F442/F442M—13e1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)

Table 1202.4, Table 1210.4

F493—14

Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings

1203.3.4

F714—13

Standard Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter

Table 1210.4

F876—15A

Specification for Cross-linked Polyethylene (PEX) Tubing

Table 1202.4, Table 1210.4

F877—11a

Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems

Table 1202.4, Table 1202.5, Table 1210.4

F1055—13

Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Cross linked Polyethylene (PEX) Pipe and Tubing

Table 1210.5, 1210.6.6.2

F1281—11

Specification for Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe

Table 1202.4

F1282—10

Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe

Table 1202.4, Table 1210.4, Table 1210.5

F1476—07(2013)

Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications

Table 1202.5, 1203.3.7

F1548—01(2012)

Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications

Table 1202.5

F1807—15

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5, Table 1210.5

F1924—12

Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing

1210.6.6.3

F1960—15

Specification for Cold-expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing

Table 1202.5

F1974—09(2005)

Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Poly ethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe

Table 1202.5

F2080—15

Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe

Table 1202.5

F2098—08

Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings

Table 1202.5

F2159—14

Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5, Table 1210.5

F2389—15

Specification for Pressure-rated Polypropylene Piping Systems

Table 1202.4, Table 1202.5, 1203.15.1, Table 1210.4, Table 1210.5, 1210.6.7.1

F2434—14

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing

Table 1210.5

F2623—14

Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR9 Tubing

Table 1202.4, Table 1210.4

F2735—09

Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing

Table 1202.5

F2769—14

Polyethylene of Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and Distribution Systems

Table 1202.4, Table 1210.5

F2806—10(2015)

Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (Metric SDR-PR)

Table 1202.4

AWS

American Welding Society
8669 NW 36 Street, #130
Miami FL 33166

A5.8M/A5.8—2011

Specifications for Filler Metals for Brazing and Braze Welding

1203.3.1, 1303.3.1

AWWA

American Water Work Association
6666 West Quincy Avenue
Denver CO 80235

C901—16

Polyethylene (PE) Pressure Pipe and Tubing, 3/4 in. (19 mm) through 3 in. (76 mm) for Water Service

Table 1210.4

C110/A21.10—12

Standard for Ductile Iron & Gray Iron Fittings

Table 1202.5

C115/A21.15—11

Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges

Table 1202.4

C151/A21.51—09

Standard for Ductile-iron Pipe, Centrifugally Cast for Water

Table 1202.4

C153/A21.53—11

Standard for Ductile-iron Compact Fittings for Water Service

Table 1202.5

CPSC

Consumer Product Safety Commission
4330 East West Highway
Bethesda MD 20814

CPSC August 2011.

Title 15 of the Federal Hazardous Substance Act

202, 1009.1

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516

B137.2—16

Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Applications

Table 1210.5

B137.3—16

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications

Table 1210.5

B137.6—16

Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot- and Cold-water Distribution Systems

Table 1210.5

B137.9—16

Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-pipe Systems

Table 1202.4, Table 1210.4, Table 1210.5

B137.10—16

Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems

Table 1202.4

CSA C448 Series—16

Design and Installation of Earth Energy Systems

Table 1210.5

CSA C22.2 No. 218.1—M89(R2011)

Spas, Hot Tubs and Associated Equipment

916.1

CSA C22.2 No. 236—11

Heating and Cooling Equipment

916.1

CSA B137.1—16

Polyethylene (PE) Pipe, Tubing and Fittings for Cold-water Pressure Services

Table 1210.4, Table 1210.5

CSA B137.5—16

Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications

Table 1210.4, Table 1210.5

CSA B137.11—16

Polypropylene (PP-R) Pipe and Fittings for Pressure Applications

Table 1210.4, Table 1210.5

CSA B137.18—13

Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications

Table 1202.4, Table 1202.5, Table 1210.5

America FC1—2012

Stationary Fuel Cell Power Systems

924.1

DOL

U.S. Department of Labor Occupational
Safety and Health Administration
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325

29 CFR Part 1910.1000 (2015)

Air Contaminants

502.6

29 CFR Part 1910.1025 (2015)

Toxic and Hazardous Substances

502.19

FDA

U.S. Food and Drug Administration
10903 New Hampshire Avenue
Silver Springs MD 20993

FDA Title 15

Federal Hazardous Substances Act

1403.4

FDA Title 21

Code of Federal Regulations, Title 21, Food and Drugs, Chapter 1, Food and Drug Administration, Parts 174—186 (revised as of April 1, 2015)

1403.3

FS

Federal Specifications* General Services Administration
7th & D Streets Specification Section, Room 6039
Washington DC 20407

WW-P-325B (1976)

Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications)
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325

Table 1202.4

ICC

International Code Council, Inc.
500 New Jersey Ave NW 6th Floor
Washington DC 20001

IECC—18

International Energy Conservation Code®

301.2, 303.3, 312.1, 401.2, 514.1, 604.1, 1204.1, 1204.2

IPC—18

International Plumbing Code®

201.3, 301.11, 307.2.2, 512.2, 908.5, 928.1, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1210.8.1, 1401.2

IRC—18

International Residential Code®

101.2

ICC 901/SRCC Standard 100—15

Solar Thermal Collector Standard

1401.4.1, 1402.8.1.1

IIAR

International Institute of Ammonia Refrigeration
1001 N. Fairfax Street, Suite 503
Arlington VA 22314

IIAR 2—2014

Safe Design of Closed-circuit Ammonia Refrigerating Systems

1101.6, 1105.6.3

ANSI/IIAR 3—2012

Ammonia Refrigeration Valves

1101.6

ANSI/IIAR 4—2015

Installation of Closed-circuit Ammonia Mechanical Refrigerating Systems

1101.6

ANSI/IIAR 5—2013

Start-up and Commissioning of Closed-circuit Ammonia Refrigeration Systems

1101.6

MSS

Manufacturers Standardization Society
of the Valve and Fittings Industry, Inc.
127 Park Street, NE
Vienna VA 22180

SP 58—2009

Pipe Hangers and Supports—Materials Design and Manufacture, Selection, Application and Installation

305.4

NAIMA

North American Insulation
Manufacturers Association
11 Canal Center Plaza, Suite 103
Alexandria VA 22314

AH116—09

Fibrous Glass Duct Construction Standards

603.5, 603.9

NBBI

National Board of Boiler and Pressure Vessel Inspectors
1055 Crupper Avenue
Columbus OH 43229-1183

NBIC—2011

National Board Inspection Code, Part 3

1003.3

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

2—16

Hydrogen Technologies Code

502.16.1

30A—18

Code for Motor Fuel-dispensing Facilities and Repair Garages

304.6

31—16

Standard for the Installation of Oil-burning Equipment

701.1, 801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1

37—18

Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines

915.1, 915.2

58—17

Liquefied Petroleum Gas Code

502.9.10

69—14

Standard on Explosion Prevention Systems

510.9.3

70—17

National Electrical Code

301.7, 306.3.1, 306.4.1, 511.1.1, 513.11, 513.12.2, 602.2.1.1, 927.2, 1104.2.2, 1106.3, 1106.4, 1402.8.1.4

72—16

National Fire Alarm and Signaling Code

606.3

82—14

Standard on Incinerators and Waste and Linen Handling Systems and Equipment

601.1

85—15

Boiler and Combustion Systems Hazards Code

1004.1

91—15

Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible Particulate Solids

502.9.5.1, 502.17

92—15

Standard for Smoke Control Systems

513.7, 513.8

96—17

Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations

507.1

211—16

Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

806.1

262—15

Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces

602.2.1.1

286—15

Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

704—17

Standard System for Identification of the Hazards of Materials for Emergency Response

502.8.4, 510.1, Table 1103.1

853—15

Standard on Installation of Stationary Fuel Power Plants

924.1

NSF

NSF International
789 N. Dixboro Road P.O. Box 130140
Ann Arbor MI 48105

NSF 358-1—2014

Polyethylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems

Table 1210.4, Table 1210.5

NSF 358-2—2012

Polypropylene Pipe and Fittings for Water-based Ground-source "Geothermal" Heat Pump Systems

Table 1210.4, Table 1210.5

SMACNA

Sheet Metal and Air Conditioning
Contractors' National Association, Inc.
4201 Lafayette Center Drive
Chantilly VA 20151-1219

SMACNA 2015

Phenolic Duct Construction Standard

603.5.2

SMACNA/ANSI—2005

HVAC Duct Construction Standards-Metal and Flexible 3rd Edition (ANSI)

603.4, Table 603.4, 603.9, 603.10

SMACNA—10

Fibrous Glass Duct Construction Standards

603.5, 603.9

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096

17—2008

Vent or Chimney Connector Dampers for Oil-fired Appliances—with revisions through September 2013

803.6

103—2010

Factory-built Chimneys, Residential Type and Building Heating Appliance—with revisions through July 2012

805.2

127—2011

Factory-built Fireplaces—with revisions through May 2015

903.1, 903.3, 903.4

174—04

Household Electric Storage Tank Water Heaters—with revisions through April 2015

1002.1

180—2012

Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids

1306.4

181—05

Factory-made Air Ducts and Air Connectors—with revisions through October 2008

512.2, 603.5, 603.6.1, 603.6.2, 603.9, 604.13

181A—2013

Closure Systems for Use with Rigid Air Ducts and Air Connectors

603.9

181B—2013

Closure Systems for Use with Flexible Air Ducts and Air Connectors

603.9

197—10

Commercial Electric Cooking Appliances—with revisions through September 2014

917.1

207—2009

Refrigerant-containing Components and Accessories, Nonelectrical—with revisions through June 2014

1101.2

263—2011

Standard for Fire Test of Building Construction and Materials—with revisions through June 2015

607.5.2, 607.5.5, 607.6.1, 607.6.2.1

268—2009

Smoke Detectors for Fire Alarm Systems

606.1

268A—2008

Smoke Detectors for Duct Application—with revisions through October 2014

606.1

343—2008

Pumps for Oil-burning Appliances—with revisions through June 2013

1302.7

378—06

Draft Equipment—with revisions through June 12, 2014

804.3, 804.3.8

391—2010

Solid-fuel and Combination-fuel Central and Supplementary Furnaces—with revisions through June 2014

918.1

412—2011

Refrigeration Unit Coolers—with revisions through September 2013

1101.2

471—2010

Commercial Refrigerators and Freezers—with revisions through December 2012

1101.2

499—05

Electric Heating Appliances—with revisions through November 2014

912.1, 923.1

507—2014

Standard for Electric Fans

505.2

508—99

Industrial Control Equipment—with revisions through October 2013

307.2.3

536—97

Flexible Metallic Hose—with revisions through December 2014

1302.8

555—06

Fire Dampers—with revisions through May 2014

607.3.1

555C—06

Ceiling Dampers—with revisions through December 2014

607.3.1

555S—99

Smoke Dampers—with revisions through February 2014

607.3.1

586—2009

High-efficiency, Particulate, Air Filter Units—with revisions through September 2014

605.2

641—2010

Type L Low-temperature Venting Systems—with revisions through June 2013

802.1

705—2004

Standard for Power Ventilators—with revisions through December 2013

504.5

710—2012

Exhaust Hoods for Commercial Cooking Equipment—with revisions through November 2013

507.1

710B—2011

Recirculating Systems—with revisions through August 2014

507.1, 507.2

723—2008

Standard for Test for Surface Burning Characteristics of Building Materials—with revisions through August 2013

510.9, 602.2, 602.2.1, 602.2.1.6, 602.2.1.7, 604.3, 1204.1

726—95

Oil-fired Boiler Assemblies—with revisions through October 2013

916.1, 1004.1

727—06

Oil-fired Central Furnace—with revisions through October 2013

918.1

729—03

Oil-fired Floor Furnaces—with revisions through October 2013

910.1

730—03

Oil-fired Wall Furnaces—with revisions through October 2013

909.1

731—95

Oil-fired Unit Heaters—with revisions through October 2013

920.1

732—95

Oil-fired Storage Tank Water Heaters—with revisions through October 2013

1002.1

737—2011

Fireplace Stoves—with revisions through August 2015

905.1

762—2010

Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances—with revisions through October 2013

506.5.1

791—06

Residential Incinerators—with revisions through November 2014

907.1

834—04

Heating, Water Supply and Power Boilers Electric—with revisions through December 2013

1004.1

842—07

Valves for Flammable Fluids—with revisions through May 2015

1307.1

858—05

Household Electric Ranges—with revisions through June 2015

917.1

867—2011

Electrostatic Air Cleaners—with revisions through August 2013

605.2

875—09

Electric Dry Bath Heater—with revisions through December 2013

914.2

896—93

Oil-burning Stoves—with revisions through November 2013

917.1, 922.1

900—04

Air Filter Units—with revisions through April 2015

605.2

907—94

Fireplace Accessories—with revisions through June 2014

902.2

923—2013

Microwave Cooking Appliances—with revisions through June 2015

917.1

959—2010

Medium Heat Appliance Factory-built Chimneys—with revisions through June 2014

805.5

1046—2010

Grease Filters for Exhaust Ducts—with revisions through January 2012

507.2.8

1240—2012

Electric Commercial Clothes—Drying Equipment—with revisions through October 2012

913.1

1261—01

Electric Water Heaters for Pools and Tubs—with revisions through July 2012

916.1

1453—04

Electric Booster and Commercial Storage Tank Water Heaters—with revisions through July 2011

1002.1

1479—03

Fire Tests of Through-penetration Firestops—with revisions through June 2015

506.3.11.2, 506.3.11.3

1482—2011

Solid-fuel Type Room Heaters—with revisions through August 2015

905.1

1563—2009

Standard for Electric Spas, Hot Tubs and Associated Equipment—with revisions through March 2015

916.1

1618—09

Wall Protectors, Floor Protectors and Hearth Extensions—with revisions through October 2015

308.4.1, 903.2, 905.3

1777—2007

Chimney Liners—with revisions through October 2015

801.16.1, 801.18.4

1812—2013

Standard for Ducted Heat Recovery Ventilators—with revisions through April 2014

514.1

1815—2012

Standard for Nonducted Heat Recovery—with revisions through April 2014

514.1

1820—04

Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—with revisions through May 2013

602.2.1.3

1887—04

Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—with revisions through May 2013

602.2.1.2

1978—2010

Grease Ducts—with revisions through September 2013

506.3.2, 506.3.6

1995—2011

Heating and Cooling Equipment—with revisions through July 2015

908.1, 911.1, 918.1, 918.2, 1101.2

1996—2009

Electric Duct Heaters—with revisions through June 2014

911.1

2024—2011

Standard for Safety Optical-fiber and Communications Cable Raceway—with revisions through August 2015

602.2.1.1

2043—2008

Fire Test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-handling Spaces—with revisions through October 2013

602.2.1.4.2

2075—2013

Standard for Gas and Vapor Detectors and Sensors

404.1

2158—97

Electric Clothes Dryers—with revisions through March 2009

913.1

2158A—2010

Outline of Investigation for Clothes Dryer Transition Duct

504.8.3

2162—01

Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type

917.1

2200—2012

Stationary Engine Generator Assemblies—with revisions through July 2015

915.1

2221—2010

Tests of Fire Resistive Grease Duct Enclosure Assemblies

506.3.11.3

2518—05

Air Dispersion System Materials

603.17

2523—09

Solid Fuel-fired Hydronic Heating Appliances—with revisions through February 2013

1002.1, 1004.1

2846—14

Fire Test of Plastic Water Distribution Plumbing Pipe for Visible Flame and Smoke Characteristics

602.2.1.7

UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING