CODES

ADOPTS WITHOUT AMENDMENTS:

International Building Code 2015 (IBC 2015)

Copyright

Preface

Effective Use of the International Building Code

Legislation

Chapter 1 Scope and Administration

Chapter 2 Definitions

Chapter 3 Use and Occupancy Classification

Chapter 4 Special Detailed Requirements Based on Use and Occupancy

Chapter 5 General Building Heights and Areas

Chapter 6 Types of Construction

Chapter 7 Fire and Smoke Protection Features

Chapter 8 Interior Finishes

Chapter 9 Fire Protection Systems

Chapter 10 Means of Egress

Chapter 11 Accessibility

Chapter 12 Interior Environment

Chapter 13 Energy Efficiency

Chapter 14 Exterior Walls

Chapter 15 Roof Assemblies and Rooftop Structures

Chapter 16 Structural Design

Chapter 17 Special Inspections and Tests

Chapter 18 Soils and Foundations

Chapter 19 Concrete

Chapter 20 Aluminum

Chapter 21 Masonry

Chapter 22 Steel

Chapter 23 Wood

Chapter 24 Glass and Glazing

Chapter 25 Gypsum Board, Gypsum Panel Products and Plaster

Chapter 26 Plastic

Chapter 27 Electrical

Chapter 28 Mechanical Systems

Chapter 29 Plumbing Systems

Chapter 30 Elevators and Conveying Systems

Chapter 31 Special Construction

Chapter 32 Encroachments Into the Public Right-Of-Way

Chapter 33 Safeguards During Construction

Chapter 34 Reserved

Chapter 35 Referenced Standards

Appendix A Employee Qualifications

Appendix B Board of Appeals

Appendix C GROUP U—AGRICULTURAL BUILDINGS

Appendix D Fire Districts

Appendix E Supplementary Accessibility Requirements

Appendix F Rodentproofing

Appendix G Flood-Resistant Construction

Appendix H Signs

Appendix I Patio Covers

Appendix J Grading

Appendix K Administrative Provisions

Appendix L Earthquake Recording Instrumentation

Appendix M Tsunami-Generated Flood Hazard

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AA Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington, VA 22209
Standard
reference
number
Title Referenced
in code
section number
ADM1‒2015 Aluminum Design Manual: Part 1‒A Specification for Aluminum Structures 1604.3.5, 2002.1
ASM 35‒00 Aluminum Sheet Metal Work in Building Construction (Fourth Edition) 2002.1

AAMA American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
1402‒09
AAMA/WDMA/CSA
Standard Specifications for Aluminum Siding, Soffit and Fascia 1404.5.1
101/I.S.2/A440‒11 North American Fenestration Standard/Specifications for
Windows, Doors and Skylights
1709.5.1, 2405.5

ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
216.1‒14 Code Requirements for Determining Fire Resistance of Concrete
and Masonry Construction Assemblies
Table 721.1(2), 722.1
318‒14 Building Code Requirements for Structural Concrete 1604.3.2, 1615.3.1, 1615.4.1,
1704.5, Table 1705.3, 1705.3.2,
1705.12.1, 1808.8.2, Table 1808.8.2, 1808.8.5, 1808.8.6,
1810.1.3, 1810.2.4.1, 1810.3.2.1.1, 1810.3.2.1.2, 1810.3.8.3.1, 1810.3.8.3.3,
1810.3.9.4.2.1, 1810.3.9.4.2.2, 1810.3.10.1, 1810.3.11.1, 1901.2, 1901.3,
1902.1, 1903.1, 1904.1, 1904.2, 1905.1, 1905.1.1, 1905.1.2,
1905.1.3, 1905.1.4, 1905.1.5, 1905.1.6, 1905.1.7, 1905.1.8
1906.1, 2108.3, 2206.1
530‒13 Building Code Requirements for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1,
2109.2, 2109.2.1, 2109.3, 2110.1
530.1‒13 Specifications for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3, 2103.1, 2103. 2.1,
2103.3, 2103.4, 2105.1

AISC American Institute of Steel
Construction One East Wacker Drive, Suite 700
Chicago, IL 60601-18021
Standard
reference
number
Title Referenced
in code
section number
341‒10 Seismic Provisions for Structural Steel Buildings 1613.4.1, 1705.12.1.1, 1705.12.1.2,
1705.13.1.1, 1705.13.1.2, 2205.2.1.1,
2205.2.1.2, 2205.2.2, 2206.2.1
360‒10 Specification for Structural Steel Buildings 722.5.2.2.1, 1604.3.3, 1705.2.1,
2203.1, 2203.2, 2205.1, 2205.2.1.1, 2206.1

AISI American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
AISI S100‒12 North American Specification for the Design of Cold-formed Steel
Structural Members, 2012
1604.3.3, 1905.1.8, 2203.1, 2203.2,
2210.1, 2210.2, 2211.2, 2211.4, 2211.6
AISI S110‒07/
S1-09 (2012)
Standard for Seismic Design of Cold-Formed Steel Structural
Systems‒Special Moment Frames, 2007 with Supplement 1, dated 2009 (Reaffirmed 2012)
2210.2
AISI S200‒12 North American Standard for Cold-Formed Steel Framing-General Provisions, 2012 2203.1, 2203.2,
2211.1, Table 2603.12.1,
Table 2603.12.2
AISI S210‒07(2012) North American Standard for Cold-Formed Steel Framing-Floor and Roof System
Design, 2007 (Reaffirmed 2012)
2211.5
AISI S211‒07/
S1-12(2012)
North American Standard for Cold-Formed Steel Framing-Wall Stud Design, 2007 including
Supplement 1, dated 2012 (Reaffirmed 2012)
2211.4
AISI S212‒07(2012) North American Standard for Cold-Formed Steel Framing-Header Design, 2007, (Reaffirmed 2012) 2211.2
AISI S213‒07/
S1-09 (2012)
North American Standard for Cold-Formed Steel Framing-Lateral
Design, 2007, with Supplement 1, dated 2009, (Reaffirmed 2012)
2211.6
AISI S214‒12 North American Standard for Cold-formed Steel Framing-Truss Design, 2012 2211.3, 2211.3.1, 2211.3.2
AISI S220‒11 North American Standard for Cold-formed Steel Framing-Nonstructural Members 2203.1, 2203.2,
2211.1, Table 2506.2, Table 2507.2
AISI S230‒07/
S3-12(2012)
Standard for Cold-formed Steel Framing-Prescriptive Method for
One- and Two-family Dwellings, 2007, with Supplement 3, dated 2012 (Reaffirmed 2012)
1609.1.1,
1609.1.1.1, 2211.7

ALI Automotive Lift Institute
P.O. Box 85
Courtland, NY 13045
Standard
reference
number
Title Referenced
in code
section number
ALI ALCTV‒2011 Standard for Automotive Lifts‒Safety Requirements for
Construction, Testing and Validation (ANSI)
3001.2

AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
Title Referenced
in code
section number
540‒08 Test Method for Louvers Impacted by Wind Borne Debris 1609.1.2.1

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A13.1‒2007 Scheme for the Identification of Piping Systems 415.11.6.5
A108.1A‒99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar 2103.2.3
A108.1B‒99 Installation of Ceramic Tile, quarry Tile on a Cured Portland
Cement Mortar Setting Bed with Dry-set or Latex-Portland Mortar
2103.2.3
A108.4‒99 Installation of Ceramic Tile with Organic Adhesives or
Water-cleanable Tile-setting Epoxy Adhesive
2103.2.3.6
A108.5‒99 Installation of Ceramic Tile with Dry-set Portland Cement Mortar
or Latex-Portland Cement Mortar
2103.2.3.1, 2103.2.3.2
A108.6‒99 Installation of Ceramic Tile with Chemical-resistant, Water
Cleanable Tile-setting and -grouting Epoxy
2103.2.3.3
A108.8‒99 Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout 2103.2.3.4
A108.9‒99 Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout 2103.2.3.5
A108.10‒99 Installation of Grout in Tilework 2103.2.3.7
A118.1‒99 American National Standard Specifications for Dry-set Portland Cement Mortar 2103.2.3.1
A118.3‒99 American National Standard Specifications for
Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and
Water Cleanable Tile-setting Epoxy Adhesive
2103.2.3.3
A118.4‒99 American National Standard Specifications for Latex-Portland Cement Mortar 2103.2.3.2, 2103.3.2.4
A118.5‒99 American National Standard Specifications for
Chemical Resistant Furan Mortar and Grouts for Tile Installation
2103.2.3.4
A118.6‒99 American National Standard Specifications for Cement Grouts for Tile Installation 2103.2.3.7
A118.8‒99 American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout 2103.2.3.5
A136.1‒99 American National Standard Specifications for
Organic Adhesives for Installation of Ceramic Tile
2103.2.3.6
A137.1‒12 American National Standard Specifications for Ceramic Tile 202
ANSI/A 190.1‒12 Structural Glued Laminated Timber 2303.1.3, 2306.1
Z 97.1‒14 Safety Glazing Materials Used in Buildings‒Safety Performance
Specifications and Methods of Test
2406.1.2, 2406.2,
Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1,
2408.2.1, 2408.3, 2409.2, 2409.3, 2409.4.1

APA APA - Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
Title Referenced
in code
section number
ANSI/A 190.1‒12 Structural Glued Laminated Timber 2303.1.3, 2306.1
ANSI/APA PRP 210‒08 Standard for Performance-Rated Engineered Wood Siding 2303.1.5, 2304.7, 2306.3, Table 2306.3(1)
ANSI/APA PRR 410‒11 Standard for Performance-Rated Engineered Wood Rim Boards 2303.1.13
APA PDS‒12 Panel Design Specification 2306.1
APA PDS
Supplement 1‒12
Design and Fabrication of Plywood Curved Panels (revised 2013) 2306.1
APA PDS
Supplement 2‒12
Design and Fabrication of Plywood-lumber Beams (revised 2013) 2306.1
APA PDS
Supplement 3‒12
Design and Fabrication of Plywood Stressed-skin Panels (revised 2013) 2306.1
APA PDS
Supplement 4‒12
Design and Fabrication of Plywood Sandwich Panels (revised 2013) 2306.1
APA PDS
Supplement 5‒12
Design and Fabrication of All-plywood Beams (revised 2013) 2306.1
APA PRG 320‒11 Standard for Performance-Rated Cross-Laminated Timber 2303.1.4
EWS R540‒12 Builders Tips: Proper Storage and Handling of Glulam Beams 2306.1
EWS S475‒07 Glued Laminated Beam Design Tables 2306.1
EWS S560‒10 Field Notching and Drilling of Glued Laminated Timber Beams 2306.1
EWS T300‒07 Glulam Connection Details 2306.1
EWS X440‒08 Product Guide-Glulam 2306.1
EWS X450‒01 Glulam in Residential Construction-Western Edition 2306.1

ASABE American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph, MI 49085
Standard
reference
number
Title Referenced
in code
section number
EP 484.2 June
1998 (R2008)
Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings 2306.1
EP 486.2 OCT 2012 Shallow-post and Pier Foundation Design 2306.1
EP 559.1 W/Corr.1
AUG 2010
Design Requirements and Bending Properties for Mechanically
Laminated Wood Assemblies
2306.1

ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
5‒13 Building Code Requirements for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9,
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2,
2109.2.1, 2109.3, 2110.1
6‒13 Specification for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3, 2103.1, 2103.2.1,
2103.3, 2103.4, 2104.1, 2105.1
7‒10 Minimum Design Loads for Buildings and Other Structures with
Supplement No. 1
202, Table 1504.8, 1602.1, 1604.3,
Table 1604.5, 1604.8.2, 1604.10, 1605.1, 1605.2.1, 1605.3.1, 1605.3.1.2,
1605.3.2, 1605.3.2.1, 1607.8.1, 1607.8.1.1, 1607.8.1.2, 1607.8.3, 1607.12.1,
1608.1, 1608.2, 1608.3, 1609.1.1, 1609.1.2, 1609.3, 1609.5.1, 1609.5.3, 1609.6,
1609.6.1, 1609.6.1.1, 1609.6.2, Table 1609.6.2, 1609.6.3, 1609.6.4.1, 1609.6.4.2,
1609.6.4.4.1, 1611.2, 1612.4, 1613.1, 1613.3.2, Table 1613.3.3(1), Table 1613.3.3(2),
1613.3.5, 1613.3.5.1, 1613.3.5.2, 1613.4, 1613.4.1, 1613.5.1, 1613.6, 1614.1, 1704.6.1, 1705.12,
1705.12.4, 1705.13.2, 1705.13.3, 1705.13.4, 1803.5.12, 1808.3.1, 1810.3.6.1, 1810.3.9.4, 1810.3.11.2,
1810.3.12, 1905.1.1, 1905.1.2, 1905.1.8, 2205.2.1.1, 2205.2.1.2, 2205.2.2, 2206.2.1, 2209.1, 2210.2,
2304.6.1, 2404.1, 2505.1, 2505.2, 2506.2.1
8‒14 Standard Specification for the Design of Cold-formed
Stainless Steel Structural Members
1604.3.3, 2210.1, 2210.2
19‒09 Structural Applications of Steel Cables for Buildings 2208.1, 2208.2
24‒14 Flood Resistant Design and Construction 1203.4.2, 1612.4, 1612.5,
2702.1.7, 3001.2
29‒14 Standard Calculation Methods for Structural Fire Protection 722.1
32‒01 Design and Construction of Frost Protected Shallow Foundations 1809.5
49‒07 Wind Tunnel Testing for Buildings and Other Structures 1609.1.1
55‒10 Tensile Membrane Structures 3102.1.1

ASME American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
ASME/A17.1‒13
CSA B44‒2013
Safety Code for Elevators and Escalators 907.3.3, 911.1.5, 1009.4,
1607.9.1, 3001.2, 3001.4, 3002.5,
3003.2, 3007.1, 3008.1.3, 3008.7.1
A17.7‒2007/
CSA B44‒07
Performance-Based Safety Code for Elevators and Escalators 3001.2
A18.1‒2008 Safety Standard for Platform Lifts and Stairway Chairlifts 1109.8
A90.1‒09 Safety Standard for Belt Manlifts 3001.2
B16.18‒2012 Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1
B16.22‒2001(R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 909.13.1
B20.1‒2009 Safety Standard for Conveyors and Related Equipment 3001.2, 3004.3
B31.3‒2012 Process Piping 415.11.6

ASSE American Society of Safety Engineers
1800 East Oakton Street
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASSE Z359.1-2007 Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components,
Part of the Fall Protection Code
1015.6, 1015.7

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A6/A6M‒11 Standard Specification for General Requirements for Rolled Structural Steel
Bars, Plates, Shapes and Sheet
1810.3.2.3, 1810.3.5.3.1, 1810.3.5.3.3
A36/A36M‒08 Specification for Carbon Structural Steel 1810.3.2.3
A153/A153M‒09 Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware 2304.10.5
A240/A240M‒13A Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate,
Sheet and Strip for Pressure Vessels and for General Applications
Table 1507.4.3(1)
A252‒10 Specification for Welded and Seamless Steel Pipe Piles 1810.3.2.3
A283/A283M‒12A Specification for Low and Intermediate Tensile Strength Carbon Steel Plates 1810.3.2.3
A416/A416M‒12A Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete 1810.3.2.2
A463/A463M‒10 Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process Table 1507.4.3(2)
A572/A572M‒12A Specification for High-strength Low-alloy Columbium-Vanadium Structural Steel 1810.3.2.3
A588/A588M‒10 Specification for High-strength Low-alloy Structural Steel with
50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance
1810.3.2.3
A615/A615M‒12 Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement 1704.5, 1810.3.10.2
A653/A653M‒11 Specification for Steel Sheet, Zinc-coated Galvanized or
Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process
Table 1507.4.3(1),
Table 1507.4.3(2), 2304.10.5.1
A690/A690M‒07(2012) Standard Specification for High-strength Low-alloy Nickel, Copper,
Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance
for Use in Marine Environments
1810.3.2.3
A706/A706M‒09b Specification for Low-alloy Steel Deformed and Plain Bars
for Concrete Reinforcement
1704.5, 2107.4, 2108.3
A722/A722M‒12 Specification for Uncoated High-strength Steel Bar for Prestressing Concrete 1810.3.10.2
A755/A755M‒2011 Specification for Steel Sheet, Metallic-coated by the Hot-dip
Process and Prepainted by the Coil-coating Process for
Exterior Exposed Building Products
Table 1507.4.3(1), Table 1507.4.3(2)
A792/A792M‒10 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated
by the Hot-dip Process
Table 1507.4.3(1), Table 1507.4.3(2)
A875/A875M‒13 Standard Specification for Steel Sheet Zinc-5 percent,
Aluminum Alloy-coated by the Hot-dip Process
Table 1507.4.3(2)
A924/A924M‒13 Standard Specification for General Requirements for Steel
Sheet, Metallic-coated by the Hot-dip Process
Table 1507.4.3(1)
B42‒10 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B43‒09 Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B68‒11 Specification for Seamless Copper Tube, Bright Annealed (Metric) 909.13.1
B88‒09 Specification for Seamless Copper Water Tube 909.13.1
B101‒12 Specification for Lead-coated Copper Sheet and Strip for
Building Construction
1404.5.3, Table 1507.2.9.2,
Table 1507.4.3(1)
B209‒10 Specification for Aluminum and Aluminum Alloy Steel and Plate Table 1507.4.3(1)
B251‒10 Specification for General Requirements for Wrought Seamless
Copper and Copper-alloy Tube
909.13.1
B280‒08 Specification for Seamless Copper Tube for Air Conditioning
and Refrigeration Field Service
909.13.1
B370‒12 Specification for Copper Sheet and Strip for
Building Construction
1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1)
B695‒04(2009) Standard Specification for Coatings of Zinc Mechanically
Deposited on Iron and Steel Strip for Building Construction
2304.10.5.1, 2304.10.5.3
C5‒10 Specification for Quicklime for Structural Purposes Table 2507.2
C22/C22M-00(2010) Specification for Gypsum Table 2506.2
C27‒98(2008) Specification for Classification of Fireclay and High-alumina Refractory Brick 2111.6
C28/C28M‒10 Specification for Gypsum Plasters Table 2507.2
C31/C31M‒12 Practice for Making and Curing Concrete Test Specimens in the Field Table 1705.3
C33/C33M‒13 Specification for Concrete Aggregates 722.3.1.4, 722.4.1.1.3
C35/C35M-1995(2009) Specification for Inorganic Aggregates for Use in Gypsum Plaster Table 2507.2
C55‒2011 Specification for Concrete Building Brick Table 722.3.2
C59/C59M‒00 (2011) Specification for Gypsum Casting Plaster and Molding Plaster Table 2507.2
C61/C61M‒00 (2011) Specification for Gypsum Keene's Cement Table 2507.2
C62‒13 Standard Specification for Building Brick
(Solid Masonry Units Made from Clay or Shale)
1807.1.6.3
C67‒13 Test Methods of Sampling and Testing Brick and Structural Clay Tile 721.4.1.1.1, 2109.3.1.1
C73‒10 Specification for Calcium Silicate Brick (Sand-lime Brick) Table 722.3.2
C90‒13 Specification for Loadbearing Concrete Masonry Units Table 722.3.2, 1807.1.6.3
C91‒12 Specification for Masonry Cement Table 2507.2
C94/C94M‒13 Specification for Ready-Mixed Concrete 110.3.1
C140‒13 Test Method Sampling and Testing Concrete Masonry Units and Related Units 722.3.1.2
C150‒12 Specification for Portland Cement 1903.1, Table 2507.2
C172/C172M‒10 Practice for Sampling Freshly Mixed Concrete Table 1705.3
C199‒84 (2011) Test Method for Pier Test for Refractory Mortars 2111.6, 2111.9, 2113.12
C206‒13 Specification for Finishing Hydrated Lime Table 2507.2
C208‒12 Specification for Cellulosic Fiber Insulating Board Table 1508.2, 2303.1.6
C216‒13 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale) 1807.1.6.3
C270‒12a Specification for Mortar for Unit Masonry 2103.3.2.4
C315‒07(2011) Specification for Clay Flue Liners and Chimney Pots 2111.9, 2113.11.1, Table 2113.16(1)
C317/C317M‒00(2010) Specification for Gypsum Concrete 2514.1
C330/C330M‒2009 Specification for Lightweight Aggregates for Structural Concrete 202
C331/C331M‒2010 Specification for Lightweight Aggregates for Concrete Masonry Units 722.3.1.4, 722.4.1.1.3
C406/C406M‒2010 Specification for Roofing Slate 1507.7.5
C472‒99 (2009) Specification for Standard Test Methods for Physical Testing of
Gypsum, Gypsum Plasters and Gypsum Concrete
Table 2506.2
C473‒12 Test Method for Physical Testing of Gypsum Panel Products Table 2506.2
C474‒13 Test Methods for Joint Treatment Materials for Gypsum Board Construction Table 2506.2
C475/C475M‒12 Specification for Joint Compound and Joint Tape for Finishing Gypsum Board Table 2506.2
C514‒04(2009)e1 Specification for Nails for the Application of Gypsum Board Table 721.1(2), Table 721.1(3),
Table 2306.7, Table 2506.2
C516‒08 Specifications for Vermiculite Loose Fill Thermal Insulation 722.3.1.4, 722.4.1.1.3
C547‒12 Specification for Mineral Fiber Pipe Insulation Table 721.1(2), Table 721.1(3)
C549‒06(2012) Specification for Perlite Loose Fill Insulation 722.3.1.4, 722.4.1.1.3
C552‒12b Standard Specification for Cellular Glass Thermal Insulation Table 1508.2
C557‒03(2009)e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing Table 2506.2
C578‒12b Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation Table 1508.2,
2603.10, Table 2603.12.1, Table 2603.12.2
C587‒04(2009) Specification for Gypsum Veneer Plaster Table 2507.2
C595/C595‒13 Specification for Blended Hydraulic Cements 1903.1, Table 2507.2
C631‒09 Specification for Bonding Compounds for Interior Gypsum Plastering Table 2507.2
C635/C635M‒13 Specification for the Manufacture, Performance and Testing of
Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
808.1.1, 2506.2.1
C636/C636M‒08 Practice for Installation of Metal Ceiling Suspension
Systems for Acoustical Tile and Lay-in Panels
808.1.1.1
C645‒13 Specification for Nonstructural Steel Framing Members Table 2506.2, Table 2507.2
C652‒13 Specification for Hollow Brick (Hollow Masonry
Units Made from Clay or Shale)
1807.1.6.3
C726‒12 Standard Specification for Mineral Roof Insulation Board Table 1508.2
C728‒05(2013) Standard Specification for Perlite Thermal Insulation Board Table 1508.2
C744‒11 Specification for Prefaced Concrete and Calcium Silicate Masonry Units Table 722.3.2
C754‒11 Specification for Installation of Steel Framing Members
to Receive Screw-attached Gypsum Panel Products
Table 2508.1, Table 2511.1.1
C836/C836M‒12 Specification for High-solids Content, Cold Liquid-applied
Elastomeric Waterproofing Membrane for Use with Separate Wearing Course
1507.15.2
C840‒11 Specification for Application and Finishing of Gypsum Board Table 2508.1, 2509.2
C841‒03(2008)E1 Specification for Installation of Interior Lathing and Furring Table 2508.1, Table 2511.1.1
C842‒05(2010)E1 Specification for Application of Interior Gypsum Plaster Table 2511.1.1, 2511.3, 2511.4
C843‒99 (2012) Specification for Application of Gypsum Veneer Plaster Table 2511.1.1
C844‒04(2010) Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster Table 2508.1
C847‒12 Specification for Metal Lath Table 2507.2
C887‒05(2010) Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar 1805.2.2, 2103.2.2
C897‒05(2009) Specification for Aggregate for Job-Mixed Portland Cement-based Plaster Table 2507.2
C920‒11 Standard for Specification for Elastomeric Joint Sealants Table 2506.2
C926‒13 Specification for Application of Portland Cement-based Plaster 2109.3.4.8, 2510.3,
Table 2511.1.1, 2511.3, 2511.4, 2512.1,
2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7
C932‒06(2013) Specification for Surface-applied Bonding Compounds for Exterior Plastering Table 2507.2
C933‒13 Specification for Welded Wire Lath Table 2507.2
C946‒10 Specification for Construction of Dry-stacked, Surface-bonded Walls 2103.2.2, 2109.2.2
C954‒11 Specification for Steel Drill Screws for the Application of Gypsum Panel Products
or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm)
to 0.112 inch (2.84 mm) in Thickness
Table 2506.2, Table 2507.2
C955‒11C Standard Specification for Load-bearing Transverse and Axial Steel Studs,
Runners Tracks, and Bracing or Bridging, for Screw Application of
Gypsum Panel Products and Metal Plaster Bases
Table 2506.2, Table 2507.2
C956‒04(2010) Specification for Installation of Cast-in-place Reinforced Gypsum Concrete 2514.1
C957‒10 Specification for High-solids Content, Cold Liquid-applied
Elastomeric Waterproofing Membrane with Integral Wearing Surface
1507.15.2
C1002‒07 Specification for Steel Self-piercing Tapping Screws for the Application of
Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
Table 2506.2, Table 2507.2
C1007‒11a Specification for Installation of Load Bearing (Transverse and
Axial) Steel Studs and Related Accessories
Table 2508.1, Table 2511.1.1
C1029‒13 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation 1507.14.2
C1032‒06(2011) Specification for Woven Wire Plaster Base Table 2507.2
C1047‒10A Specification for Accessories for Gypsum
Wallboard and Gypsum Veneer Base
Table 2506.2, Table 2507.2
C1063‒12D Specification for Installation of Lathing and Furring to Receive
Interior and Exterior Portland Cement-based Plaster
2109.3.4.8, 2510.3,
Table 2511.1.1, 2512.1.1
C1088‒13 Specification for Thin Veneer Brick Units Made from Clay or Shale Table 721.1(2)
C1157/C1157M‒11 Standard Performance Specification for Hydraulic Cement 1903.1, Table 2507.2
C1167‒11 Specification for Clay Roof Tiles 1507.3.4
C1177/C1177M‒08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing Table 1508.2, Table 2506.2
C1178/C1178M‒11 Specification for Coated Mat Water-resistant Gypsum Backing Panel Table 2506.2, Table 2509.2
C1186‒08(2012) Specification for Flat Fiber Cement Sheets 1404.10, 1405.16.1, 1405.16.2
C1261‒10 Specification for Firebox Brick for Residential Fireplaces 2111.6, 2111.9
C 1278/
C1278M‒07a(2011) Specification for Fiber-reinforced Gypsum Panels Table 1508.2, Table 2506.2
C1280‒13 Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing Table 2508.1, 2508.2
C1283‒11 Practice for Installing Clay Flue Lining 2113.9.1, 2113.12
C1288‒99(2010) Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets Table 2509.2
C1289‒13E1 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board Table 1508.2
2603.0, Table 2603.12.1,
Table 2603.12.2
C1313/C1313M‒12 Standard Specification for Sheet Radiant Barriers for Building Construction Applications 1509.4
C1325‒08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Backer Units Table 2509.2
C1328/C1328M‒12 Specification for Plastic (Stucco Cement) Table 2507.2
C1364‒10B Standard Specification for Architectural Cast Stone 2103.1
C1386‒07 Specification for Precast Autoclaved Aerated
Concrete (AAC) Wall Construction Units
202
C1396M/C1396M‒13 Specification for Gypsum Board Figure 722.5.1(2), Figure 722.5.1(3)
C1492‒03(2009) Standard Specification for Concrete Roof Tile 1507.3.5
C1600/C 1600M‒11 Standard Specification for Rapid Hardening Hydraulic Cement Table 2507.2
C1629/
C1629M‒06(2011)
Standard Classification for Abuse-resistant Nondecorated
Interior Gypsum Panel Products and Fiber-reinforced Cement Panels
403.2.3.1, 403.2.3.2, 403.2.3.4
C1658/C1658M‒12 Standard Specification for Glass Mat Gypsum Panels Table 2506.2
D25‒12 Specification for Round Timber Piles 1810.3.2.4, 2303.1.12
D41‒05 Specification for Asphalt Primer
Used in Roofing, Dampproofing and Waterproofing
Table 1507.10.2
D43‒00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D56‒05(2010) Test Method for Flash Point By Tag Closed Tester 202
D86‒2012 Test Method for Distillation of Petroleum Products at Atmospheric Pressure 202
D93‒2012 Test Method for Flash Point By Pensky-Martens Closed Cup Tester 202
D225‒07 Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules 1507.2.5
D226/D226M‒09 Specification for Asphalt-saturated Organic Felt
Used in Roofing and Waterproofing
1404.2, 1505.2, 1507.2.3, 1507.2.8.1, 1507.3.3, 1507.4.5
1507.5.3, 1507.6.3, 1507.6.3.1, 1507.7.3, Table 1507.8,
1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2, 1507.17.3, 1507.17.4.1
D227/D227M‒
03(2011)E1
Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing Table 1507.10.2
D312‒00 (2006) Specification for Asphalt Used in Roofing Table 1507.10.2
D422‒63 (2007) Test Method for Particle-size Analysis of Soils 1803.5.3
D448‒08 Standard Classification for Sizes of Aggregate for Road and Bridge Construction 1507.12.3, 1507.13.3
D450‒07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing Table 1507.10.2
D635‒10 Test Method for Rate of Burning and/or Extent and
Time of Burning of Plastics in a Horizontal Position
2606.4
D1143/D1143M‒07e1 Test Method for Piles Under Static Axial Compressive Load 1810.3.3.1.2
D1227‒95 (2007) Specification for Emulsified Asphalt Used as a Protective Coating for Roofing Table 1507.10.2, 1507.15.2
D1557‒12 Test Method for Laboratory Compaction Characteristics
of Soil Using Modified Effort [56,000 ft-lb/ft3 (2,700 KN m/m3)]
1705.6, 1804.5
D1863/D1863M‒
05(2011)E1
Specification for Mineral Aggregate Used on Built-up Roofs Table 1507.10.2
D1929‒12 Test Method for Determining Ignition Temperature of Plastics 402.6.4.4, 406.7.2, 1407.11.2.1,
1407.11.3.3, 1407.11.4.2, 2606.4
D1970/D1970M‒2013 Specification for Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof
Underlayment for Ice Dam Protection
1507.2.4, 1502.2.8.1, 1507.2.9.2, 1507.3.3.3
1507.3.9, 1507.4.5, 1507.5.3.1, 1507.5.7, 1507.6.3.1,
1507.7.3.1, 1507.8.3.1, 1507.8.8, 1507.9.3.1, 1507.9.9, 1507.17.4.1
D2178‒04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D2487‒2011 Practice for Classification of Soils for Engineering
Purposes (Unified Soil Classification System)
Table 1610.1, 1803.5.1
D2626/D2626M‒
04(2012)E1
Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing 1507.3.3
Table 1507.10.2
D2822/
D2822M-05(2011)E1
Specification for Asphalt Roof Cement, Asbestos Containing Table 1507.10.2
D2823/D2823M‒
05(2011)E1
Specification for Asphalt Roof Coatings, Asbestos Containing Table 1507.10.2
D2824‒06(2012)E1 Standard Specification for Aluminum-Pigmented Asphalt Roof Coating,
Nonfibered, Asbestos Fibered and Fibered without Asbestos
Table 1507.10.2
D2843‒10 Test for Density of Smoke from the Burning or Decomposition of Plastics 2606.4
D2859‒06(2011) Standard Test Method for Ignition Characteristics of Finished
Textile Floor Covering Materials
804.4.1
D2898‒10 Test Methods for Accelerated Weathering of Fire-retardant-treated
Wood for Fire Testing
1505.1, 2303.2.4, 2303.2.6
D3019‒08 Specification for Lap Cement Used with Asphalt Roll Roofing,
Nonfibered, Asbestos Fibered and Nonasbestos Fibered
Table 1507.10.2
D3161/D3161M‒13 Test Method for a Wind Resistance of Asphalt Shingles
(Fan Induced Method)
1504.1.1, Table 1504.1.1, 1507.17.8
D3200‒74 (2012) Standard Specification and Test Method for Establishing Recommended
Design Stresses for Round Timber Construction Poles
2303.1.12
D3201‒2013 Test Method for Hygroscopic Properties of Fire-retardant-treated
Wood and Wood-based Products
2303.2.7
D3278‒1996 (2011) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D3462/D3462M‒10A Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules 1507.2.5
D3468‒99 (2006) e01 Specification for Liquid-applied Neoprene and
Chlorosulfonated Polyethylene Used in Roofing and Waterproofing
1507.15.2
D3679‒11 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding 1404.9, 1405.14
D3689‒2013E1 Test Methods for Deep Foundations Under Static Axial Tensile Load 1810.3.3.1.5
D3737‒2012 Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam) 2303.1.3
D3746‒85 (2008) Test Method for Impact Resistance of Bituminous Roofing Systems 1504.7
D3747‒79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table 1507.10.2
D3909/
D3909M‒97b (2012)e1
Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules 1507.2.9.2, 1507.6.5,
Table 1507.10.2
D3957‒09 Standard Practices for Establishing Stress Grades
for Structural Members Used in Log Buildings
2303.1.11
D4022/D4022M‒
2007(2012)E1
Specification for Coal Tar Roof Cement, Asbestos Containing Table 1507.10.2
D4272‒09 Test Method for Total Energy Impact of Plastic Films by Dart Drop 1504.7
D4318‒10 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils 1803.5.3
D4434/D4434M‒12 Specification for Poly (Vinyl Chloride) Sheet Roofing 1507.13.2
D4479/D4479M‒
07(2012)E1
Specification for Asphalt Roof Coatings-Asbestos-free Table 1507.10.2
D4586/D4586M‒
07(2012)E1
Specification for Asphalt Roof Cement-Asbestos-free Table 1507.10.2
D4601/D4601M‒
04(2012)E1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table 1507.10.2
D4637/D4637M‒13 Specification for EPDM Sheet Used in Single-ply Roof Membrane 1507.12.2
D4829‒11 Test Method for Expansion Index of Soils 1803.5.3
D4869/D4869M‒
05(2011)e01
Specification for Asphalt-saturated (Organic Felt)
Underlayment Used in Steep Slope Roofing
1507.2.3,
1507.2.8.1, 1507.4.5, 1507.5.3,
1507.5.3.1, 1507.6.3, 1507.7.3, 1507.7.3.1,
1507.8.3, 1507.8.3.1, 1507.9.3, 1507.9.3.1, 1507.17.3, 1507.17.4.1
D4897/D4897M‒
01(2009)
Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing Table 1507.10.2
D4945‒12 Test Method for High-strain Dynamic Testing of Piles 1810.3.3.1.2
D4990‒97a (2005) e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table 1507.10.2
D5019‒07a Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane 1507.12.2
D5055‒13 Specification for Establishing and Monitoring Structural
Capacities of Prefabricated Wood I-joists
2303.1.2
D5456‒12 Specification for Evaluation of Structural Composite Lumber Products 2303.1.10
D5516‒09 Test Method of Evaluating the Flexural Properties of Fire-retardant-treated
Softwood Plywood Exposed to the Elevated Temperatures
2303.2.5.1
D5643/D5643M‒
06(2012)E1
Specification for Coal Tar Roof Cement, Asbestos-free Table 1507.10.2
D5664‒10 Test Methods for Evaluating the Effects of Fire-retardant Treatment and
Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber
2303.2.5.2
D5665‒99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied
Roofing and Waterproofing
Table 1507.10.2
D5726‒98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied
Roofing and Waterproofing
Table 1507.10.2
D6083‒05e01 Specification for Liquid Applied Acrylic Coating Used in Roofing Table 1507.10.2, Table 1507.14.3,
1507.15.2
D6162‒2000A (2008) Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
1507.11.2
D6163‒00 (2008) Specification for Styrene-butadiene-styrene (SBS) Modified
Bituminous Sheet Materials Using Glass Fiber Reinforcements
1507.11.2
D6164/D6164M‒11 Specification for Styrene-butadiene-styrene (SBS) Modified
Bituminous Sheet Metal Materials Using Polyester Reinforcements
1507.11.2
D6222/D6222M‒11 Specification for Atactic Polypropylene (APP) Modified
Bituminous Sheet Materials Using Polyester Reinforcements
1507.11.2
D6223/D6223M‒
02(2011)E1
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet
Materials Using a Combination of Polyester and Glass Fiber Reinforcements
1507.11.2
D6298‒05e1 Specification for Fiberglass Reinforced Styrene-butadiene-styrene
(SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface
1507.11.2
D6305‒08 Practice for Calculating Bending Strength Design Adjustment
Factors for Fire-retardant-treated Plywood Roof Sheathing
2303.2.5.1
D6380‒03 (2009) Standard Specification for Asphalt Roll Roofing (Organic) Felt 1507.2.9.2, 1507.3.3, 1507.6.5
D6509/D6509M‒09 Standard Specification for Atactic Polypropylene (APP)
Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements
1507.11.2
D6694‒08 Standard Specification for Liquid-applied Silicone Coating
Used in Spray Polyurethane Foam Roofing Systems
Table 1507.14.3, 1507.15.2
D6754/D6745M‒10 Standard Specification for Ketone Ethylene Ester Based Sheet Roofing 1507.13.2
D6757‒2013 Standard Specification for Underlayment for Use with Steep Slope Roofing 1507.2.3, 1507.17.3, 1507.17.4.1
D6841‒08 Standard Practice for Calculating Design Value Treatment
Adjustment Factors for Fire-retardant-treated Lumber
2303.2.5.2
D6878/D6878M‒11a Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing 1507.13.2
D6947‒07 Standard Specification for Liquid Applied Moisture Cured
Polyurethane Coating Used in Spray Polyurethane Foam Roofing System
.Table 1507.14.3, 1507.15.2
D7032‒10a Standard Specification for Establishing Performance Ratings for Wood,
Plastic Composite Deck Boards and Guardrail Systems (Guards or Rails)
2612.2.1, 2612.4, 2612.5.1
D7147‒05 Specification for Testing and Establishing Allowable Loads of Joist Hangers 2303.5, 2304.10.3
D7158/D7158M‒11 Standard Test Method for Wind Resistance of Sealed
Asphalt Shingles (Uplift Force/Uplift Resistance Method)
1504.1.1, Table 1504.1.1
D7254‒07 Standard Specification for polypropylene (PP) siding 1404.12
D7655‒12 Standard Classification for Size of Aggregate Used as Ballast for Roof Membrane Systems 1507.12.3, 1507.13.3
D7672‒2012 Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies 2303.1.13
E84‒2013A Test Methods for Surface Burning Characteristics of Building Materials 202, 402.6.4.4, 406.7.2, 703.5.2,
720.1, 720.4, 803.1.1, 803.1.4, 803.10, 803.11,
806.7, 1404.12.1, 1407.9, 1407.10.1, 1409.9, 1409.10.1,
1510.6.2, 1510.6.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4,
2603.7.1, 2603.7.2, 2603.7.3, 2604.2.4, 2606.4,
2612.3, 2614.3, 3105.4
E90‒09 Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements
1207.2, 1207.2.1
E96/E96M‒2013 Test Method for Water Vapor Transmission of Materials 202
E108‒2011 Test Methods for Fire Tests of Roof Coverings 1505.1, 2603.6, 2610.2, 2610.3
E119‒2012A Standard Test Methods for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3,
703.3, 703.4, 703.6, 704.12,
705.7, 705.8.5, 711.3.2, 714.3.1, 714.4.1, 715.1,
716.2, Table 716.3, 716.5.6, 716.5.8.1.1,
Table 716.6, 716.6.7.1, 717.5.2, 717.5.3, 717.6.1,
716.6.2.1, Table 721.1(1), 1409.10.2,
2103.1, 2603.5.1
E136‒2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 703.5.1
E283‒04 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows
Curtain Walls, and Doors Under Specified Pressure Difference Across the Specimen
202
E330‒02 Test Method for Structural Performance of Exterior Windows, Curtain Walls and
Doors by Uniform Static Air Pressure Difference
1409.10.2, 1709.5.2
E331‒00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights,
Doors and Curtain Walls by Uniform Static Air Pressure Difference
1403.2
E492‒09 Test Method for Laboratory Measurement of Impact Sound Transmission Through
Floor-ceiling Assemblies Using the Tapping Machine
1207.3
E605‒93 (2011) Test Method for Thickness and Density of Sprayed
Fire-resistive Material (SFRM) Applied to Structural Members
1705.14.4.1, 1705.14.4.2,
1705.14.4.5, 1705.14.5
E681‒2009 Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases 202
E736‒00 (2011) Test Method for Cohesion/Adhesion of Sprayed Fire-resistive
Materials Applied to Structural Members
704.13.2, 1705.14.6
E814‒2013 Test Method of Fire Tests of Through-penetration Firestops 202, 714.3.1.2, 714.3.2, 7143.4.1.1.2
E970‒2010 Test Method for Critical Radiant Flux of Exposed Attic
Floor Insulation Using a Radiant Heat Energy Source
720.3.1
E1300‒12AE1 Practice for Determining Load Resistance of Glass in Buildings 2404.1, 2404.2, 2404.3.1,
2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5
E1354‒2013 Standard Test Method for Heat and Visible Smoke Release Rates for
Materials and Products Using an Oxygen Consumption Calorimeter
424.2
E1592‒05(2012) Test Method for Structural Performance of Sheet Metal Roof and Siding Systems
by Uniform Static Air Pressure Difference
1504.3.2
E1602‒02(2010)E1 Guide for Construction of Solid Fuel-burning Masonry Heaters 2112.2
E1886‒05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors and
Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials
1609.1.2
E1966‒07A(2011) Test Method for Fire-resistant Joint Systems 202, 715.3
E1996‒2012A Specification for Performance of Exterior Windows, Curtain Walls,
Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
1609.1.2, 1609.1.2.2
E2072‒10 Standard Specification for Photoluminescent (Phosphorescent) Safety Markings 1025.3
E2174‒10AE1 Standard Practice for On-Site Inspection of Installed Fire Stops 1705.17.1
E2178‒13 Standard Test Method for Air Permeance of Building Materials 202
E2273‒03(2011) Standard Test Method for Determining the Drainage Efficiency of
Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies
1408.4.1
E2307‒2010 Standard Test Method for Determining Fire Resistance of
a Perimeter Joint System Between an Exterior Wall Assembly and
Floor Assembly Using the Intermediate-scale, Multistory Test Apparatus
715.4
E2393‒10A Standard Practice for On-Site Inspection of Installed
Fire Resistive Joint Systems and Perimeter Fire Barrier
1705.17.2
E2397‒11 Standard Practice for Determination of Dead Loads and Live Loads Associated
with Green Roof Systems
1607.12.3.1
E2404‒2013E1 Standard Practice for Specimen Preparation and Mounting of Textile, Paper or
Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics
803.1.4
E2556‒10 Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers
Intended for Mechanical Attachment
1404.2, 2510.6
E2568‒09e1 Standard Specification for PB Exterior Insulation and Finish Systems 1408.2
E2570‒07 Standard Test Method for Evaluating Water-resistive Barrier (WRB)
Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage
1408.4.1.1,
1705.16.1
E2573‒12 Standard Practice for Specimen Preparation and Mounting of Site-fabricated
Stretch Systems to Assess Surface Burning Characteristics
803.13
E2599‒11 Standard Practice for Specimen Preparation and Mounting of Reflective Insulation
Materials and Vinyl Stretch Ceiling Materials for Building Applications to
Assess Surface Burning Characteristics
2614.3
E2634‒11 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems 1903.4
E2751‒11 Standard Practice for Design and Performance of Supported Glass Walkways 2409.1
F547‒(2012) Terminology of Nails for Use with Wood and Wood-based Materials Table 2506.2
F1667‒11AE1 Specification for Driven Fasteners: Nails, Spikes and Staples Table 721.1(2), Table 721.1(3),
1507.2.6, 1507.17.5, 2303.6, Table 2506.2
F2006‒00 (2005) 10 Standard/Safety Specification for Window Fall Prevention Devices for
Nonemergency Escape (Egress) and Rescue (Ingress) Windows
1015.8
F2090‒10 Specification for Window Fall Prevention Devices with Emergency
Escape (Egress) Release Mechanisms
1015.8, 1015.8.1
F2200‒2013 Standard Specification for Automated Vehicular Gate Construction 3110.3
G152‒06 Practice for Operating Open Flame Carbon Arc Light Apparatus for
Exposure of Nonmetallic Materials
1504.6
G154‒06 Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials 1504.6
G155‒05a Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials 1504.6

AWC American Wood Council
222 Catoctin SE, Suite 201
Leesburg, VA 20175
Standard
reference
number
Title Referenced
in code
section number
AWC WCD No. 4‒2003 Wood Construction Data‒Plank and Beam Framing for Residential Buildings 2306.1.2
AWC WFCM‒2015 Wood Frame Construction Manual for One- and Two-Family Dwellings 1609.1.1, 1609.1.1.1,
2301.2, 2308.2.4, 2309.1
ANSI/AWC NDS‒2015 National Design Specification (NDS) for
Wood Construction with 2015 NDS Supplement
202, 722.1, Table 1604.3, 1809.12,
1810.3.2.4, Table 1810.3.2.6, 1905.1.8,
2304.13, 2306.1, Table 2306.2(1), Table 2306.2(2),
Table 2306.3(1), Table 2306.3(2), 2307.1
AWC STJR‒2015 Span Tables for Joists and Rafters 2306.1.1, 2308.4.2.1, 2308.7.1, 2308.7.2
ANSI/AWC PWF‒2015 Permanent Wood Foundation Design Specification 1805.2, 1807.1.4, 2304.10.5.2
AWC SDPWS‒2015 Special Design Provisions for Wind and Seismic 202, 2305.1, 2305.2, 2305.3, 2306.1, 2306.2,
2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1

AWCI Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church, VA 22046
Standard
reference
number
Title Referenced
in code
section number
12-B‒04 Technical Manual 12-B Standard Practice for the Testing and Inspection of
Field Applied Thin Film Intumescent Fire-resistive
Materials; an Annotated Guide, Second Edition
1705.15

AWPA American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
Title Referenced
in code
section number
C1‒03 All Timber Products-Preservative Treatment by Pressure Processes 1505.6
M4‒11 Standard for the Care of Preservative-treated Wood Products 1810.3.2.4.1, 2303.1.9
U1‒14 USE CATEGORY SYSTEM: User Specification for Treated Wood
Except Section 6, Commodity Specification H
1403.6, Table 1507.9.6, 1807.1.4, 1807.3.1,
1809.12, 1810.3.2.4.1, 2303.1.9,
2304.12.1, 2304.12.2, 2304.12.3, 2304.2.4, 2304.12.5

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
Standard
reference
number
Title Referenced
in code
section number
D1.4/D1.4M‒2011 Structural Welding Code-Reinforcing Steel Including Metal Inserts and
Connections In Reinforced Concrete Construction
1704.5, 1705.3.1, Table 1705.3, 2107.4

BHMA Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
Standard
reference
number
Title Referenced
in code
section number
A 156.10‒2011 Power Operated Pedestrian Doors 1010.1.4.2
A 156.19‒2013 Standard for Power Assist and Low Energy Operated Doors 1010.1.4.2
A 156.27‒11 Power and Manual Operated Revolving Pedestrian Doors 1010.1.4.1

CEN European Committee for Standardization (CEN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
Title Referenced
in code
section number
EN 1081‒98 Resilient Floor Coverings‒Determination of the Electrical Resistance 406.7.1
BS EN 15250‒2007 Slow Heat Release Appliances Fired By Solid Fuel Requirements and Test Methods 2112.2, 2112.5

CGSB Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
37-GP-52M (1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric 1504.7, 1507.12.2
37-GP-56M (1980) Membrane, Modified, Bituminous, Prefabricated and
Reinforced for Roofing‒with December 1985 Amendment
1507.11.2
CAN/CGSB 37.54‒95 Polyvinyl Chloride Roofing and Waterproofing Membrane 1507.13.2

CPA Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4‒2012 Basic Hardboard 1404.3.1, 2303.1.7
ANSI A135.5‒2012 Prefinished Hardboard Paneling 2303.1.7, 2304.7
ANSI A135.6‒2012 Engineered Wood Siding 1404.3.2, 2303.1.7
A208.1‒09 Particleboard 2303.1 8, 2303.1. 8.1

CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1201 (2002) Safety Standard for Architectural Glazing Material 2406.2, Table 2406.2(1),
2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1,
2408.3, 2409.2, 2409.3.1, 2409.4.1
16 CFR Part 1209 (2002) Interim Safety Standard for Cellulose Insulation 720.6
16 CFR Part 1404 (2002) Cellulose Insulation 720.6
16 CFR Part 1500 (2009) Hazardous Substances and Articles; Administration and Enforcement Regulations 202
16 CFR Part 1500.44(2009) Method for Determining Extremely Flammable and Flammable Solids 202
16 CFR Part 1507 (2002) Fireworks Devices 202
16 CFR Part 1630 (2007) Standard for the Surface Flammability of Carpets and Rugs 804.4.1

CSA Canadian Standards Association
8501 East Pleasant Valley
Cleveland, OH 44131-5516
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440‒11
Specifications for Windows, Doors and Unit Skylights 1709.5.1, 2405.5

CSSB Cedar Shake and Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
Title Referenced
in code
section number
CSSB‒97 Grading and Packing Rules for Western Red Cedar Shakes and
Western Red Shingles of the Cedar Shake and Shingle Bureau
Table 1507.8.5, Table 1507.9.6

DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
ANSI/DASMA 107‒1997
(R2012)
Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation 2603.4.1.9
108‒12 Standard Method for Testing Sectional Garage Doors and
Rolling Doors: Determination of Structural Performance
Under Uniform Static Air Pressure Difference
1709.5.2
115‒12 Standard Method for Testing Sectional Garage Doors and
Rolling Doors: Determination of Structural
Performance Under Missile Impact and Cyclic Wind Pressure
1609.1.2.3

DOC U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS-1‒09 Structural Plywood 2303.1.5, 2304.7, Table 2304.7(4),
Table 2304.7(5), Table 2306.2(1), Table 2306.2(2)
PS-2‒10 Performance Standard for Wood-based Structural-use Panels 2303.1.5, 2304.7, Table 2304.7(5),
Table 2306.2(1), Table 2306.2(2)
PS 20‒05 American Softwood Lumber Standard 202, 1810.3.2.4, 2303.1.1

DOL U.S. Department of Labor
Frances Perkins Building
200 Constitution Avenue NW
Washington, DC 20210
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000 (2009) Air Contaminants 202

DOTn U.S. Department of Transportation
c/o Superintendent of Documents
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
Title Referenced
in code
section number
49 CFR Parts 100‒185
2005
Hazardous Materials Regulations 202
49 CFR Parts 173.137
(2009)
Shippers‒General Requirements for Shipments and Packaging‒
Class 8‒Assignment of Packing Group
202
49 CFR‒1998 Specification of Transportation of Explosive and Other
Dangerous Articles, UN 0335, UN 0336 Shipping Containers
202

FEMA Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington, DC 20472
Standard
reference
number
Title Referenced
in code
section number
FEMA-TB-11‒01 Crawlspace Construction for Buildings Located in Special Flood Hazard Areas 1805.1.2.1

FM Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston, RI 02919
Standard
reference
number
Title Referenced
in code
section number
4430 (2012) Approval Standard for Heat and Smoke Vents 910.3.1
4470 (2012) Approval Standard for Single-Ply Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR)
And Liquid Applied Roof Assemblies for use in Class 1 and
Noncombustible Roof Deck Construction
1504.7
4474 (2011) American National Standard for Evaluating the Simulated Wind Uplift Resistance of
Roof Assemblies Using Static Positive and/or Negative Differential Pressures
1504.3.1, 1504.3.2
4880-2010 Approval Standard for Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels,
Interior Finish Materials or Coatings and Exterior Wall Systems
2603.4, 2603.9

GA Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville, MD 20782
Standard
reference
number
Title Referenced
in code
section number
GA 216‒13 Application and Finishing of Gypsum Panel Products Table 2508.1, 2509.2
GA 600‒12 Fire-Resistance Design Manual, 20th Edition Table 721.1(1), Table 721.1(2), Table 721.1(3)

HPVA Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston, VA 20190
Standard
reference
number
Title Referenced
in code
section number
HP-1‒2013 Standard for Hardwood and Decorative Plywood 2303.3, 2304.7

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
ICC A117.1‒09 Accessible and Usable Buildings and Facilities 202, 907.5.2.3.3, 1009.8.2, 1009.9,
1009.11, 1010.1.9.7, 1012.1, 1012.6.5,
1012.10, 1013.4, 1023.9, 1101.2, 1111.2,
1111.3, 1111.4, 1111.4.2
ICC 300‒12 ICC Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1029.1.1
Table 1607.1
ICC 400‒12 Standard on Design and Construction of Log Structures 2301.2
ICC 500‒14 ICC/NSSA Standard on the Design and Construction of Storm Shelters 202, 423.1, 423.3, 423.4
ICC 600‒14 Standard for Residential Construction in High-wind Regions 1609.1.1, 1609.1.1.1, 2308.2.1
IEBC‒15 International Existing Building Code® 101.4.7, 116.5, 201.3
IECC‒15 International Energy Conservation Code® 101.4.6, 201.3, 202, 1203.1, 1301.1.1, 1405.3
IFC‒15 International Fire Code® 101.4.5, 102.6, 201.3, 202, 307.1, Table 307.1(1), Table 307.1(2),
307.1.1, 307.1.2, 403.4.5, 404.2, 406.7, 406.8, 407.2.6, 407.4, 410.3.6,
411.1, 412.1, 412.6.1, 413.1, 414.1.1, 414.1.2, 414.1.2.1, 414.2, 414.2.5,
Table 414.2.5(1), Table 414.2.5(2), 414.3, 414.5, 414.5.1, Table 414.5.1,
414.5.2, 414.5.3, 414.5.4, 414.6, 415.1, 415.6, 415.6.1, 415.6.1.1, 415.6.1.4,
Table 415.6.2, 415.7.3, 415.8.2, 415.9, 415.9.1, 415.9.1.3, 415.9.1.4, 415.9.1.6,
415.9.1.7, 415.9.1.8, 415.9.2, 415.9.3, 415.10, 415.11, 415.11.1.7, 415.11.4,
415.11.7.2, 415.11.9.3, 415.11.10.1, 416.1, 416.4, 421.1, 422.3.1, 426.1.4, Table 504.3,
Table 504.4, Table 506.2, 507.4, 507.8.1.1.1, 507.8.1.1.2, 507.8.1.1.3, 705.8.1, 707.1, 901.2,
901.3, 901.5, 901.6.2, 901.6.3, 903.1.1, 903.2.7.1, 903.2.11.6, 903.2.12, 903.5, 904.2.1,
904.12.3, 905.1, 905.3.6, 906.1, 907.1.8, 907.2.5, 907.2.13.2, 907.2.15, 907.2.16,
907.6.5, 907.8, 909.20, 910.2.2, 1001.3, 1001.4, 1010.1.9.6, 1203.5.2, 1203.6,
1507.16, 1512.1, Table 1604.5, 2603.4.1.12, 2702.1, 2702.1.2, 2702.2.3, 2702.2.8,
2702.2.9, 2702.2.11, 2702.2.12, 2702.2.13, 2702.4, 3003.3, 3008.1.2, 3102.1, 3103.1,
3111.1, 3111.1.1, 3302.3, 3303.7, 3309.2
IFGC‒15 International Fuel Gas Code® 101.4.1, 201.3, Table 307.1(1), 415.9.2, 2113.11.1.2,
2113.15, 2801.1
IMC‒15 International Mechanical Code® 101.4.2, 201.3, 307.1.1, Table 307.1(1), 406.6.2,
406.8.2, 406.8.4, 409.3, 412.6.6, 414.1.2, 414.3, 415.8.1.4,
415.8.2, 415.8.2.7, 415.8.3, 415.8.4, 415.10.11, 415.10.11.1, 416.2.2,
413.3, 416.3, 417.1, 419.8, 421.5, 603.1, 603.1.1, 603.1.2, 712.1.6,
717.2.2, 717.5.3, 717.5.4, 717.6.1, 717.6.2, 717.6.3, 718.5,
720.1, 720.7, 903.2.11.4, 904.2.1, 904.11, 907.3.1, 908.6, 909.1, 909.10.2,
909.13.1, 1006.2.2.3, 1011.6, 1020.5.1, 1203.1, 1203.2.1,
1203.5.2, 1203.5.2.1,
1203.6, 1209.3, 2801.1
IPC‒15 International Plumbing Code® 101.4.3, 201.3, 415.9.3, 603.1.2, 718.5,
903.3.5, 904.12.1.3, 912.6, 1206.3.3, 1503.4, 1503.4.1, 1805.4.3,
2901.1, Table 2902.1, 3305.1, A101.2
IPMC‒15 International Property Maintenance Code® 101.4.4, 102.6, 103.3
IPSDC‒15 International Private Sewage Disposal Code® 101.4.3, 2901.1
IRC‒15 International Residential Code® 101.2, 305.2.3, 308.3.4, 308.4.2, 308.6.4,
310.1, 310.5.1, 310.5.2, 2308.1
IWUIC‒15 International Wildland-Urban Interface Code® Table 1505.1
SBCCI SSTD 11‒97 Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles 1504.2.1.1, 1504.2.1.2

ISO International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
ISO 8115‒86 Cotton Bales‒Dimensions and Density Table 307.1(1), Table 415.11.1.1.1
ISO 8336‒09 Fiber-Cement Flat Sheets - Product Specification and Test Methods 1404.10, 1405.16.1,
1405.16.2, Table 2509.2

MHI Material Handling Institute
8720 Red Oak Blvd. Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
ANSI MH29.1‒08 Safety Requirements for Industrial Scissors Lifts 3001.2

NAAMM National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn, IL 60137
Standard
reference
number
Title Referenced
in code
section number
FP 1001‒07 Guide Specifications for Design of Metal Flag Poles 1609.1.1

NCMA National Concrete Masonry Association
13750 Sunrise Valley
Herndon, VA 22071-4662
Standard
reference
number
Title Referenced
in code
section number
TEK 5‒84 (1996) Details for Concrete Masonry Fire Walls Table 721.1(2)

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
10‒13 Standard for Portable Fire Extinguishers 906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)
11‒10 Standard for Low Expansion Foam 904.7
12‒11 Standard on Carbon Dioxide Extinguishing Systems 904.8, 904.11
12A‒09 Standard on Halon 1301 Fire Extinguishing Systems 904.9
13‒13 Installation of Sprinkler Systems 708.2, 903.3.1.1, 903.3.2, 903.3.8.2, 903.3.8.5
904.11, 905.3.4, 907.6.4, 1019.3
13D‒13 Standard for the Installation of Sprinkler Systems in One- and Two-family
Dwellings and Manufactured Homes
903.3.1.3
13R‒13 Standard for the Installation of Sprinkler Systems in
Low Rise Residential Occupancies
903.3.1.2, 903.3.5.2, 903.4
14‒13 Standard for the Installation of Standpipe and Hose System 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
16‒15 Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems 904.7, 904.11
17‒13 Standard for Dry Chemical Extinguishing Systems 904.6, 904.11
17A‒13 Standard for Wet Chemical Extinguishing Systems 904.5, 904.11
20‒13 Standard for the Installation of Stationary Pumps for Fire Protection 913.1, 913.2.1, 913.5
30‒12 Flammable and Combustible Liquids Code 415.6, 507.8.1.1.1, 507.8.1.1.2
31‒11 Standard for the Installation of Oil-burning Equipment 2113.15
32‒11 Standard for Dry Cleaning Plants 415.9.3
40‒11 Standard for the Storage and Handling of Cellulose Nitrate Film 409.1
58‒14 Liquefied Petroleum Gas Code 415.9.2
61‒13 Standard for the Prevention of Fires and Dust Explosions in
Agricultural and Food Product Facilities
426.1
70‒14 National Electrical Code 108.3, 415.11.1.8, 904.3.1, 907.6.1, 909.12.2, 909.16.3,
1205.4.1, 2701.1, 2702.1.2, G501.4, G1001.6,
H106.1, H106.2, K101, K111.1
72‒13 National Fire Alarm and Signaling Code 407.4.4.3, 407.4.4.5, 407.4.4.5.1,
901.6, 903.4.1, 904.3.5, 907.2, 907.2.6, 907.2.11,
907.2.13.2, 907.3, 907.3.3, 907.3.4, 907.5.2.1.2, 907.5.2.2,
907.5.2.2.5, 907.6, 907.6.1, 907.6.2, 907.6.6, 907.7, 907.7.1, 907.7.2,
907.2.9.3, 911.1.5, 2702.2.4, 3005.5, 3007.7
80‒13 Standard for Fire Doors and Other Opening Protectives 410.3.5, 509.4.2, 716.5, 716.5.7, 716.5.8.1,
716.5.9.2, 716.6, 716.6.4, 1010.1.4.3
82‒14 Standard on Incinerators and Waste and Linen Handling Systems and Equipment 713.13
85‒15 Boiler and Combustion System Hazards Code 415.8.1
92‒15 Standard for Smoke Control Systems 909.7, 909.8
99‒15 Health Care Facilities Code 407.10, 425.1
101‒15 Life Safety Code 1029.6.2
105‒13 Standard for Smoke Door Assemblies and Other Opening Protectives 405.4.2, 710.5.2.2,
716.5.3.1, 909.20.4.1
110‒13 Standard for Emergency and Standby Power Systems 2702.1.2
111‒13 Standard on Stored Electrical Energy Emergency and Standby Power Systems 2702.1.2
120‒15 Standard for Fire Prevention and Control in Coal Mines 426.1
170‒15 Standard for Fire Safety and Emergency Symbols 1025.2.6.1
211‒13 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 2112.5
221‒15 Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls 706.2
252‒12 Standard Methods of Fire Tests of Door Assemblies 715.4.2, 715.4.3, 715.4.7.3.1, Table 716.3,
716.3.1, 716.4, 716.5.1, 716.5.3, 716.5.8, 716.5.8.1.1
253‒15 Standard Method of Test for Critical Radiant Flux of Floor Covering Systems
Using a Radiant Heat Energy Source
406.8.3, 424.2, 804.2, 804.3
257‒12 Standard for Fire Test for Window and Glass Block Assemblies Table 716.3, 716.4, 716.5.3.2, 716.6,
716.6.1, 716.6.2, 716.6.7.3
259‒13 Standard Test Method for Potential Heat of Building Materials 2603.4.1.10, 2603.5.3
265‒11 Standard Methods of Fire Tests for Evaluating Room Fire Growth
Contribution of Textile Wall Coverings on Full Height Panels and Walls
803.1.3, 803.1.3.1
268‒12 Standard Test Method for Determining Ignitability of Exterior
Wall Assemblies Using a Radiant Heat Energy Source
1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2,
2603.5.7, D105.1
275‒13 Standard Method of Fire Tests for the Evaluation of Thermal Barriers 1407.10.2, 2603.4
276‒11 Standard Method of Fire Tests for Determining the Heat Release Rate of
Roofing Assemblies With Combustible Above-Deck Roofing Components
1508.1, 2603.3, 2603.4.1.5
285‒12 Standard Fire Test Method for the Evaluation of Fire Propagation Characteristics of
Exterior Nonload-bearing Wall Assemblies Containing Combustible Components
718.2.6, 1403.5,
1407.10.4, 1409.10.4,
1510.6.2, 2603.5.5
286‒15 Standard Methods of Fire Test for Evaluating Contribution of
Wall and Ceiling Interior Finish to Room Fire Growth
402.6.4.4, 803.1.2, 803.1.2.1, 803.11,
2603.4, 2603.7.2, 2603.9, 2604.2.4, 2614.4
288‒12 Standard Methods of Fire Tests of Horizontal Fire Door Assemblies
Installed in Horizontal in Fire-resistance-rated Floor Systems
712.1.13.1
289‒13 Standard Method of Fire Test for Individual Fuel Packages 402.6.2, 424.2
409‒11 Standard for Aircraft Hangars 412.4.6, Table 412.4.6, 412.4.6.1, 412.6.5
418‒11 Standard for Heliports 412.8.4
484‒15 Standard for Combustible Metals 426.1
654‒13 Standard for the Prevention of Fire & Dust Explosions from the Manufacturing,
Processing and Handling of Combustible Particulate Solids
426.1
655‒12 Standard for the Prevention of Sulfur Fires and Explosions 426.1
664‒12 Standard for the Prevention of Fires and Explosions in Wood Processing and
Woodworking Facilities
426.1
701‒10 Standard Method of Fire Tests for Flame-Propagation of Textiles and Films 410.3.6, 424.2, 801.4, 806.1,
806.3, 806.4, 3102.3, 3102.3.1,
3102.6.1.1, 3105.4, D102.2.8, H106.1.1
704‒12 Standard System for the Identification of the Hazards of
Materials for Emergency Response
202, 415.5.2
720‒15 Standard for the Installation of Carbon Monoxide (CO) Detection and
Warning Equipment
9151.6.1, 915.1.6.2
750‒14 Standard on Water Mist Fire Protection Systems 904.12.1.1
1124‒06 Code for the Manufacture, Transportation and Storage of Fireworks and
Pyrotechnic Articles
415.6.1.1
2001‒15 Standard on Clean Agent Fire Extinguishing Systems 904.10

PCI Precast Prestressed Concrete Institute
200 West Adams Street, Suite 2100
Chicago, IL 60606-6938
Standard
reference
number
Title Referenced
in code
section number
MNL 124‒11 Design for Fire Resistance of Precast Prestressed Concrete 722.2.3.1
MNL 128‒01 Recommended Practice for Glass Fiber Reinforced Concrete Panels 1903.3

PTI Post-Tensioning Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
PTI DC‒10.5-12 Standard Requirements for Design and Analysis of Shallow Concrete
Foundations on Expansive Soils
1808.6.2

RMI Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte, NC 28217
Standard
reference
number
Title Referenced
in code
section number
ANSI/MH16.1‒12 Specification for Design, Testing and Utilization of Industrial Steel Storage Racks 2209.1

SBCA Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
Standard
reference
number
Title Referenced
in code
section number
ANSI/FS 100-12 Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating
Sheathing Used in Exterior Wall Covering Assemblies
2603.10

SDI Steel Deck Institute
P. O. Box 426
Glenshaw, PA 15116
Standard
reference
number
Title Referenced
in code
section number
ANSI/NC1.0‒10 Standard for Noncomposite Steel Floor Deck 2210.1.1.1
ANSI/RD1.0‒10 Standard for Steel Roof Deck 2210.1.1.2
SDI-C‒2011 Standard for Composite Steel Floor Deck Slabs 2210.1.1.3
SDI-QA/QC‒2011 Standard for Quality Control and Quality Assurance for Installation of Steel Deck 1705.2.2

SJI Steel Joist Institute
1173B London Links Drive
Forest, VA 24551
Standard
reference
number
Title Referenced
in code
section number
CJ‒10 Standard Specification for Composite Steel Joists, CJ-series 1604.3.3, 2203.2, 2207.1
JG‒10 Standard Specification for Joist Girders 1604.3.3, 2203.2, 2207.1
K‒10 Standard Specification for Open Web Steel Joists, K-series 1604.3.3, 2203.2, 2207.1
LH/DLH‒10 Standard Specification for Longspan Steel Joists, LH-series
and Deep Longspan Steel Joists, DLH-series
1604.3.3, 2203.2, 2207.1

SPRI Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham, MA 02452
Standard
reference
number
Title Referenced
in code
section number
ANSI/SPRI/
FM4435-ES-1‒11
Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems 1504.5
ANSI/SPRI RP-4‒13 Wind Design Guide for Ballasted Single-ply Roofing Systems 1504.4
ANSI/SPRI VF1‒10 External Fire Design Standard for Vegetative Roofs 1505.10

TIA Telecommunications Industry Association
1320 N. Courthouse Road
Arlington, VA 22201-3834
Standard
reference
number
Title Referenced
in code
section number
222-G‒05 Structural Standards for Antenna Supporting Structures and Antennas,
including‒Addendum 1, 222-G-1, Dated 2007, Addendum 2, 222-G-2 Dated 2009
Addendum 3, 222-3 dated 2013 and Addendum 4, 222-G-4 dated 2014
1609.1.1,
3108.1, 3108.2

TMS The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501
Standard
reference
number
Title Referenced
in code
section number
216‒2013 Standard Method for Determining Fire Resistance of Concrete
and Masonry Construction Assemblies
Table 721.1(2), 722.1
302‒2012 Standard Method for Determining the Sound Transmission Class
Rating for Masonry Walls
1207.2.1
402‒2013 Building Code for Masonry Structures 1405.6, 1405.6.1, 1405.6.2, 1405.10, 1604.3.4,
1705.4, 1705.4.1, 1807.1.6.3, 1807.1.6.3.2, 1808.9
2101.2, 2106.1, 2107.1, 2107.2, 2107.3, 2107.4,
2108.1, 2108.2, 2108.3, 2109.1, 2109.1.1, 2109.2, 2109.2.1, 2109.3, 2110.1
403‒2013 Direct Design Handbook for Masonry Structures 2101.2
602‒2013 Specification for Masonry Structures 1405.6.1, 1705.4, 1807.1.6.3,
2103.1, 2103.2.1, 2103.3, 2103.4, 2104.1, 2105.1

TPI Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
TPI 1‒2014 National Design Standard for Metal-plate-connected Wood Truss Construction 2303.4.6, 2306.1

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
9‒2009 Fire Tests of Window Assemblies 715.5.2, 716.3.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.8.1
10A‒2009 Tin Clad Fire Doors 716.5
10B‒2008 Fire Tests of Door Assemblies‒with Revisions through April 2009 716.5.2
10C‒2009 Positive Pressure Fire Tests of Door Assemblies 716.5.1, 716.5.3, 1010.1.10.1
14B‒2008 Sliding Hardware for Standard Horizontally mounted Tin Clad Fire Doors
with Revisions Through May 3, 2013
716.5
14C‒06 Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs‒
with Revisions through May 2013
716.5
55A‒04 Materials for Built-Up Roof Coverings 1507.10.2
103‒2010 Factory-built Chimneys, for Residential Type and Building Heating Appliances‒
with Revisions through July 2012
718.2.5.1
127‒2011 Factory-built Fireplaces 718.2.5.1, 2111.11
199E‒04 Outline of Investigation for Fire Testing of Sprinklers and
Water Spray Nozzles for Protection of Deep Fat Fryers
904.11.4.1
217‒06 Single and Multiple Station Smoke Alarms‒with Revisions through April 2012 907.2.11
263‒11 Standard for Fire Tests of Building Construction and Materials 703.2, 703.2.1, 703.2.3, 703.3, 703.4,
703.6, 704.12, 705.7, 705.8.5, 707.7, 711.3.2, 714.3.1,
714.4.1.1, 715.1, 716.2, Table 716.3, 716.5.6, 716.5.8.1.1,
716.7.1, 717.5.2, 717.5.3, 717.6.2.1, Table 721.1(1),
1407.10.2, 2103.1, 2603.4, 2603.5.1
268‒09 Smoke Detectors for Fire Alarm Systems 407.8, 907.2.6.2, 907.2.11.7
294‒1999 Access Control System Units‒with Revisions through September 2010 1010.1.9.6, 1010.1.9.8, 1010.1.9.9
300‒05(R2010) Fire Testing of Fire Extinguishing Systems for Protection of
Commercial Cooking Equipment‒with Revisions through July 16, 2010
904.11
300A‒06 Outline of Investigation for Extinguishing System Units for Residential Range
Top Cooking Surfaces
407.2.6, 904.13
305‒2012 Panic Hardware 1010.1.10.1
325‒02 Door, Drapery, Gate, Louver and Window Operations and Systems‒
with Revisions through June 2013
406.3.6, 3110.4
555‒2006 Fire Dampers‒with Revisions through May 2012 717.3
555C‒2006 Ceiling Dampers‒with Revisions through May 2010 717.3
555S‒99 Smoke Dampers‒with Revisions through May 2012 717.3, 717.3.1
580‒2006 Test for Uplift Resistance of Roof Assemblies
with Revisions through July 2009
1504.3.1, 1504.3.2
641‒2010 Type L Low-temperature Venting Systems‒with Revisions through May 2013 2113.11.1.4
710B‒2011 Recirculating Systems 904.11
723‒2008 Standard for Test for Surface Burning Characteristics of
Building Materials‒with Revisions through September 2010
202, 402.6.4.4,
406.7.2, 703.5.2, 720.1, 720.4, 803.1.1,
803.1.4, 803.10, 803.11, 806.7, 1404.12.1, 1407.9, 1407.10.1,
1409.9, 1409.10.1, 1510.6.2, 1510.6.3, 2303.2, 2603.3,
2603.4.1.13, 2606.3.5.4, 2603.7.1, 2603.7.2, 2603.7.3,
2604.2.4, 2606.4, 2612.3, 2614.3, 3105.4
790‒04 Standard Test Methods for Fire Tests of Roof Coverings
with Revisions through October 2008
1505.1, 2603.6, 2610.2, 2610.3
793‒08 Standards for Automatically Operated Roof Vents for Smoke and Heat‒
with Revisions through September 2011
406.8.5.1.1, 910.3.1
864‒03 Standards for Control Units and Accessories for Fire Alarm Systems
with Revisions through August 2012
421.6.2, 909.12
924‒06 Standard for Safety Emergency Lighting and Power Equipment‒
with Revisions through February 2011
1013.5
1040‒96 Fire Test of Insulated Wall Construction‒
with Revisions through October 2012
1407.10.3, 1409.10.3, 2603.4, 2603.9
1256‒02 Fire Test of Roof Deck Construction‒
with Revisions through January 2007
1508.1, 2603.3, 2603.4.1.5
1479‒03 Fire Tests of Through-penetration Firestops
with Revisions through October 2012
202, 714.3.1.2, 714.3.2, 714.4.1.2, 714.4.4
1482‒2011 Solid-Fuel-type Room Heaters 2112.2, 2112.5
1703‒02 Flat-Plate Photovoltaic Modules and Panels
with Revisions through November 2014
1505.9, 1507.17.1, 1507.17.6, 1509.7.4
1715‒97 Fire Test of Interior Finish Material‒
with Revisions through January 2013
1407.10.3, 1409.10.2, 1409.10.3, 2603.4, 2603.9, 2614.4
1777‒2007 Chimney Liners‒with Revisions through July 2009 2113.11.1, 2113.19
1784‒01 Air Leakage Tests of Door Assemblies‒
with Revisions through July 2009
710.5.2.2, 710.5.2.2.1, 716.5.3.1, 716.5.7.1,
716.5.7.3, 3006.3, 3007.6.3, 3008.6.3
1897‒12 Uplift Tests for Roof Covering Systems 1504.3.1
1975‒06 Fire Test of Foamed Plastics Used for Decorative Purposes 402.6.2, 402.6.4.5, 424.2
1994‒04 Luminous Egress Path Marking Systems‒
with Revisions through November 2010
411.7, 1025.2.1, 1025.2.3, 1025.2.4, 1025.4
2017‒2008 Standards for General-purpose Signaling Devices and Systems‒
with Revisions through May 2011
406.8.5.1.1
2034‒2008 Standard for Single- and Multiple-Station Carbon Monoxide Alarm‒
with Revisions through February 2009
915.4.2, 915.4.3
2075‒2013 Standard for Gas and Vapor Detectors and Sensors 421.6.2, 406.8.5.1.1, 915.5.1, 915.5.3
2079‒04 Tests for Fire Resistance of Building Joint Systems‒
with Revisions through December 2012
202, 715.3, 715.6
2196‒2001 Tests for Fire Resistive Cables‒with Revisions through March 2012 913.2.2, 2702.3
2200‒2012 Stationary Engine Generator Assemblies‒with Revisions through June 2013 2702.1.1

ULC Underwriters Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R3B4
Standard
reference
number
Title Referenced
in code
section number
CAN/ULC S 102.2‒2010 Standard Method of Test for Surface Burning Characteristics of Flooring,
Floor Coverings and Miscellaneous Materials and Assemblies‒with 2000 Revisions
720.4

USC United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
732 North Capitol Street NW
Washington, DC 20401
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Ch.40 Importation, Manufacture, Distribution and Storage of Explosive Materials 202

WCLIB West Coast Lumber Inspection Bureau
P. O. Box 23145
Portland, OR 97281
Standard
reference
number
Title Referenced
in code
section number
AITC Technical
Note 7‒96
Calculation of Fire Resistance of Glued Laminated Timbers 722.6.3.3
AITC 104‒03 Typical Construction Details 2306.1
AITC 110‒01 Standard Appearance Grades for Structural Glued Laminated Timber 2306.1
AITC 113‒10 Standard for Dimensions of Structural Glued Laminated Timber 2306.1
AITC 117‒10 Standard Specifications for Structural Glued Laminated Timber of Softwood Species 2306.1
AITC 119‒96 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species 2306.1
AITC 200‒09 Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber 2306.1

WDMA Window and Door Manufacturers Association
2025 M Street, NW Suite 800
Washington, DC 20036-3309
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440‒11
Specifications for Windows, Doors and Unit Skylights 1709.5.1, 2405.5

WRI Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford, CT 06103
Standard
reference
number
Title Referenced
in code
section number
WRI/CRSI‒81 Design of Slab-on-ground Foundations‒with 1996 Update 1808.6.2
Resources