AAMA/WDMA/CSA 101/I.S.2/A C440—17:

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

R402.4.3

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206

Manual J—16:

Residential Load Calculation Eighth Edition

R403.6

Manual S—14:

Residential Equipment Selection

R403.6

ANSI

American National Standards Institute
25 West 43rd Street 4th Floor
New York NY 10036

Z21-50-2016/CSA 2.22—16:

Vented Decorative Gas Appliances

R402.4.2.1, R403.1.3

Z21.88-2017/CSA 2.23—17:

Vented Gas Fireplace Heaters

R402.4.2.1

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria VA 22314

APSP 14—14:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

APSP 15a—2013:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency

R403.12

ASHRAE

American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc
1791 Tullie Circle NE
Atlanta GA 30329

ASHRAE 90.1:

Energy Standard for Buildings Except Low-rise Residential Buildings

Table RA103.3.7.1(1), Table RA103.3.7.1(2)

ASHRAE 193—2010(RA 2014):

Method of Test for Determining the Airtightness of HVAC Equipment

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

C90:

Standard Specification for Loadbearing Concrete Masonry Units

Table RA103.3.7.1(2)

C236—87:

Standard Test Method for Steady-state Thermal Performance of Building Assemblies by Means of a Guarded Hot Box

Table RA103.3.7.1(1)

C1363—11:

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

R303.1.4.1

E283—04(2012):

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

R402.4.4

E779—10:

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

R402.4.1.2

E1827—11:

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

R402.4.1.2

CSA

Canadian Standards Association
5060 Spectrum Way
Mississauga Ontario, Canada L4W 5N6

AAMA/WDMA/CSA 101/I.S.2/A440—17:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

CSA 55.1—2015:

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Systems

R403.5.4, Table R406.2

CSA 55.2—2015:

Drain Water Heat Recovery Units

R403.5.4

CSA P.4.1—2015:

Testing Method for Measuring Annual Fireplace Efficiency

R403.5.4

DASMA

Door & Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland OH 44115-2851

105—2016:

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

HVI

Home Ventilating Institute
1000 North Rand Road, Suite 214
Wauconda IL 60084

916—09:

Airflow Test Procedure

R303.1.3

ICC

International Code Council, Inc.
500 New Jersey Avenue NW 6th Floor
Washington DC 20001

IBC—17:

International Building Code®

R201.3, R303.2, R402.11, R4501.4

ICC 400—17:

Standard on the Design and Construction of Log Structures

Table R402.1.1

IPMC—17:

International Property Maintenance Code®

R501.4

IRC—17:

International Residential Code®

R104.2.1, R201.3, R303.2, R401.2, R403.2.2, R403.5, R406.1, R406.2, Table R406.2

NEEA

Northwest Energy Efficiency Alliance
421 SW 6th Avenue, Suite 600
Portland OR 97204

NEEA—2011:

Northern Climate Specification for Heat Pump Water Heaters, Vers. 4.0

Table R406.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

70—17:

National Electrical Code

R501.4

NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD 20770

100—2010:

Procedure for Determining Fenestration Products U-factors—Second Edition

R303.1.3

200—2010:

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second Edition

R303.1.3

400—2010:

Procedure for Determining Fenestration Product Air Leakage—Second Edition

R402.4.3

RESNET

Residential Energy Services Network, Inc.
P.O. Box 4561
Oceanside CA 92052-4561

ANSI/RESNET/ICC 301—2014:

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016

R406.3

ANSI/RESNET/ICC 380—2016:

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems—Republished January 2016

R402.4.1.2

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062

127—11:

Standard for Factory Built Fireplaces—with Revisions through May 2015

R402.4.2

515—11:

Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015

R403.5.1.2

US-FTC

United States Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC 20580

CFR Title 16 (May 31, 2005):

R-value Rule

R303.1.4

WDMA

Window and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines IL 60018

AAMA/WDMA/CSA 101/I.S.2/A440—11:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

WSU

Washington State University Energy Extension Program
905 Plum Street SE, Bldg 3
PO Box 43165
Olympia WA 98506-3166

WSU RS 33:

Duct Testing Standard for New and Existing Construction Publication No. WSUEEP12-016

R403.2.2