The documents or portions thereof listed in this chapter are referenced within this Code and shall be considered part of the requirements of this document.
National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471.

NFPA 10, Standard for Portable Fire Extinguishers, 2013 edition.

NFPA 13, Standard for the Installation of Sprinkler Systems, 2016 edition.

NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 2014 edition.

NFPA 37, Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines, 2015 edition.

NFPA 70®, National Electrical Code®, 2014 edition.

NFPA 75, Standard for the Fire Protection of Information Technology Equipment, 2016 edition.

NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2015 edition.

NFPA 101®, Life Safety Code®, 2015 edition.

NFPA 110, Standard for Emergency and Standby Power Systems, 2016 edition.

NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems, 2016 edition.

NFPA 170, Standard for Fire Safety and Emergency Symbols, 2015 edition.

NFPA 601, Standard for Security Services in Fire Loss Prevention, 2015 edition.

NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment, 2015 edition.

NFPA 1031, Standard for Professional Qualifications for Fire Inspector and Plan Examiner, 2014 edition.

NFPA 1221, Standard for the Installation, Maintenance, and Use of Emergency Services Communications Systems, 2016 edition.

NFPA 1600®, Standard on Disaster/Emergency Management and Business Continuity Programs, 2013 edition.

NFPA 1620, Standard for Pre-Incident Planning, 2015 edition.

American National Standards Institute, Inc., 25 West 43rd Street, 4th Floor, New York, NY 10036.

ANSI A-58.1, Building Code Requirements for Minimum Design Loads in Buildings and Other Structures.

ANSI S1.4a, Specifications for Sound Level Meters, 1985, reaffirmed 2006.

ANSI S3.41, American National Standard Audible Emergency Evacuation Signal, 1990, reaffirmed 2008.

ANSI/ASME A17.1/CSA B44-13, Safety Code for Elevators and Escalators, 2013.

ANSI/IEEE C2, National Electrical Safety Code, 2007.

ANSI/TIA-568-C.3, Optical Fiber Cabling Components Standard, June 2008.

ANSI/UL 217, Standard for Single and Multiple Station Smoke Alarms, 6th edition, 2006, revised 2012.

ANSI/UL 268, Standard for Smoke Detectors for Fire Alarm Systems, 6th edition, 2009.

ANSI/UL 827, Standard for Central-Station Alarm Services, 7th edition, 2008, revised 2013.

ANSI/UL 864, Standard for Control Units and Accessories for Fire Alarm Systems, 9th edition, 2003, revised 2012.

ANSI/UL 985, Standard for Household Fire Warning System Units, 5th edition, 2000, revised 2008.

ANSI/UL 1638, Visual Signaling AppliancesPrivate Mode Emergency and General Utility Signaling, 4th edition, 2001, revised 2013.

ANSI/UL 1730, Standard for Smoke Detector Monitors and Accessories for Individual Living Units of Multifamily Residences and Hotel/Motel Rooms, 4th edition, 2006, revised 2012.

ANSI/UL 1971, Standard for Signaling Devices for the Hearing Impaired, 3rd edition, 2002, revised 2013.

ANSI/UL 1981, Central Station Automation Systems, 2nd edition, 2003, revised 2012.

ANSI/UL 2017, Standard for General-Purpose Signaling Devices and Systems, 2nd edition, 2008, revised 2011.

ANSI/UL 2572, Mass Notification Systems, 1st edition, 2011, revised 2012.

ANSI/UL 60950, Information Technology Equipment — Safety — Part 1: General Requirements, 2nd edition, 2007, revised 2011.

Electronic Industries Alliance, 2500 Wilson Boulevard, Arlington, VA 22201-3834.

EIA Tr 41.3, Telephones.

International Municipal Signal Association, 165 East Union Street, Newark, NY 14513-0539.

"IMSA Official Wire and Cable Specifications," 2012.

International Organization for Standardization, 1, ch. de la Voie-Creuse, Case postale 56, CH-1211 Geneva 20, Switzerland.

ISO 7731, Danger signals for public and work places — Auditory danger signals, 2003 (reconfirmed 2009).

Telcordia Technologies, One Telcordia Drive, Piscataway, NJ 08854.

GR-506-CORE, LATA Switching Systems Generic Requirements: Signaling for Analog Interface, 2006.

GR-909-CORE, Fiber in the Loop Systems Generic Requirements, 2004.

Merriam-Webster's Collegiate Dictionary, 11th edition, Merriam-Webster, Inc., Springfield, MA, 2003.

NFPA 70®, National Electrical Code®, 2014 edition.

NFPA 101®, Life Safety Code®, 2015 edition.

NFPA 654, Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, 2013 edition.

NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment, 2015 edition.

NFPA 1221, Standard for the Installation, Maintenance, and Use of Emergency Services Communications Systems, 2016 edition.

NFPA 5000®, Building Construction and Safety Code®, 2015 edition.