CODES

ADOPTS WITH AMENDMENTS:

International Wildland-Urban Interface Code 2015 (IWUIC 2015)

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard.

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
D 2898‒10 Standard Test Methods for Accelerated Weathering of
Fire-Retardant-Treated Wood for Fire Testing
503.2
D 3201‒13 Standard Test Methods for Hygroscopic Properties of Fire-Retardant Wood and
Wood-based Products
503.2
D 3909/D3909M
‒97b (2012e1)
Standard Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with
Mineral Granules
504.2, 504.2.1, 505.2,
505.2.1, 506.2, 506.2.1
D 6662‒13 Standard Specification for Polyolefin-based Plastic Lumber Decking Boards 503.2
D 7032‒10a Standard Specification for Establishing Performance Ratings for
Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails)
503.2
E 84‒2013A Test Method for Surface-Burning Characteristics of Building Materials 202, 503.2
E 108‒11 Standard Test Methods for Fire Tests of Roof Coverings 504.2, 505.2, 506.2
E 119‒2012a Standard Test Methods for Fire Tests of Building Construction and Materials 501.3
E 136‒2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 202
E 1354‒13 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and
Products Using and Oxygen Consumption Calorimeter
504.7, 505.7
E 2632/E2632‒13E1 Standard Test Method for Evaluating the Under-Deck Fire Test Response of Deck Materials 504.7, 505.7
E 2768‒2011 Standard Test Method for Extended Duration Surface Burning Characteristics of
Building Materials (30 Minute Tunnel Test)
503.2

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC‒15 International Building Code® 103.3, 107.1, 107.3, 108.3, 202, 404.10.3, 501.1, 501.2, 501.3, 503.2,
504.3, 504.5, 504.6, 504.7, 504.11, 505.5, 505.6,
505.7, 505.11, A107.5
IFC‒15 International Fire Code® 102.6, 107.1, 107.3, 202, 402.1.1, 402.2.1, 403.2,
403.2.3, 404.10.3, 606.1, 606.2, A104.6, A105.1, A107.5
IPMC‒15 International Property Maintenance Code® 102.6

NFPA National Fire Protection Association
Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
NFPA 70‒14 National Electrical Code 404.10.3, A107.5

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
263‒2011 Standard for Fire Test of Building Construction and Materials 501.3
723‒2008 Standard for Test for Surface Burning Characteristics of Building
Materials‒with Revisions through September 2010
202, 503.2
790‒2004 Standard Test Methods for Fire Tests of Roof Coverings‒
with revisions through October 2008
504.2, 505.2, 506.2
Resources