Chapter 6 [RE] Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R106.

AAMA American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173-4268
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A C440—11
North American Fenestration Standard/
Specifications for Windows, Doors and Unit Skylights
R402.4.3

ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual J—11 Residential Load Calculation Eighth Edition R403.6
Manual S—13 Residential Equipment R403.6

APSP The Association of Pool and Spa Professionals
2111 Eisenhower Avenue
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
APSP 14—11 American National Standard for Portable Electric Spa Energy Efficiency R403.11
APSP 15a—2013 American National Standard for Residential Swimming Pool
and Spa Energy Efficiency
R403.12

ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2013 ASHRAE Handbook of Fundamentals R402.1.4, Table R405.5.2(1)
ASHRAE 193—2010 Method of Test for Determining the Airtightness of HVAC Equipment R403.2.2.1

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2859
Standard
reference
number
Title Referenced
in code
section number
C 1363—11 Standard Test Method for Thermal Performance of Building Materials
and Envelope Assemblies by Means of a Hot Box Apparatus
R303.1.4.1
E 283—04 Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
R402.4.4
E 779—10 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization R402.4.1.2
E 1827—11 Standard Test Method for Determining Airtightness of Building Using
an Orifice Blower Door
R402.4.1.2

CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
R402.4.3

DASMA Door and Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
105—92(R2004)—13 Test Method for Thermal Transmittance and Air Infiltration of Garage Doors R303.1.3

ICC International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—15 International Building Code R201.3, R303.2, R402.2.10
ICC 400—12 Standard on the Design and Construction of Log Structures Table R402.4.1.1
IFC—15 International Fire Code R201.3
IFGC—15 International Fuel Gas Code R201.3
IMC—15 International Mechanical Code R201.3, R403.2.2, R403.5
IRC—15 International Residential Code R201.3, R303.2, R402.2.10, R403.2.2, R403.5


NEEA Northwest Energy Efficiency Alliance
421 SW 6th Ave, Suite 600
Portland, OR 97204
Standard
reference
number
Title Referenced
in code
section number
NEEA-2011 Northern Climate Specification for Heat Pump Water Heaters, Vers. 4.0 Table R406.2

NFRC National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
Standard
reference
number
Title Referenced
in code
section number
100—2009 Procedure for Determining Fenestration Products U-factors—Second Edition R303.1.3
200—2009 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients
and Visible Transmittance at Normal Incidence—Second Edition
R303.1.3
400—2009 Procedure for Determining Fenestration Product Air Leakage—Second Edition R402.4.3


US-FTC United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
Title Referenced
in code
section number
CFR Title 16
(May 31, 2005)
R-value Rule R303.1.4

WDMA Window and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
R402.4.3

WSU Washington State University Energy Extension Program
905 Plum Street SE, Bldg 3
PO Box 43165
Olympia, WA 98506-3166
Standard
reference
number
Title Referenced
in code
section number
WSU RS 33 Duct Testing Standard for New and Existing Construction Publication No. WSUEEP12-016 R403.2.2