This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206
Standard
reference
number
TitleReferenced
in code
section number

Manual D—09

Residential Duct Systems

603.2

183—2007

Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings

312.1

AHRI

Air-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington VA 22203
Standard
reference
number
TitleReferenced
in code
section number

700—2006

Purity Specifications for Fluorocarbon and Other Refrigerants

1102.2.2.3

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL 60004
Standard
reference
number
TitleReferenced
in code
section number

550—08

Test Method for High Velocity Wind Driven Rain Resistant Louvers

401.5501.3.2

ANSI

American National Standards Institute
11 West 42nd Street
New York NY 10036
Standard
reference
number
TitleReferenced
in code
section number

Z21.8—1994 (R2002)

Installation of Domestic Gas Conversion Burners

919.1

ASHRAE

American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta GA 30329
Standard
reference
number
TitleReferenced
in code
section number

ASHRAE—2009

ASHRAE Fundamentals Handbook

603.2

15—2010

Safety Standard for Refrigeration Systems

1101.61105.81108.1

34—2010

Designation and Safety Classification of Refrigerants

2021102.2.11103.1

62.1—2010

Ventilation for Acceptable Indoor Air Quality

403.3.2.3.2

ASME

American Society of Mechanical Engineers
Three Park Avenue
New York NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number

B1.20.1—1983 (R2006)

Pipe Threads, General Purpose (Inch)

1203.3.51303.3.3

B16.3—2006

Malleable Iron Threaded Fittings, Classes 150 & 300

Table 1202.5

B16.5—2003

Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24

Table 1202.5

B16.9—2007

Factory Made Wrought Steel Buttwelding Fittings

Table 1202.5

B16.11—2005

Forged Fittings, Socket-welding and Threaded

Table 1202.5

B16.15—2006

Cast Bronze Threaded Fittings

Table 1202.5

B16.18—2001 (Reaffirmed 2005)

Cast Copper Alloy Solder Joint Pressure Fittings

513.13.1Table 1202.5

B16.22—2001 (Reaffirmed 2005)

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

513.13.1Table 1202.5

B16.23—2002 (Reaffirmed 2006)

Cast Copper Alloy Solder Joint Drainage Fittings DWV

Table 1202.5

B16.24—2006

Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500

Table 1202.5

B16.26—2006

Cast Copper Alloy Fittings for Flared Copper Tubes

Table 1202.5

B16.28—1994

Wrought Steel Buttwelding Short Radius Elbows and Returns

Table 1202.5

B16.29—2007

Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV

Table 1202.5

B31.9—08

Building Services Piping

1201.3

BPVC—2007

ASME Boiler & Pressure Vessel Code—07 Edition

1004.11011.1

CSD-1—2009

Controls and Safety Devices for Automatically Fired Boilers

1004.1

ASSE

American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake OH 44145
Standard
reference
number
TitleReferenced
in code
section number

1017—2010

Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems

1002.2.2

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428
Standard
reference
number
TitleReferenced
in code
section number

A 53/A 53M—07

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless

Table 1202.4Table 1302.3

A 106/A106M—08

Specification for Seamless Carbon Steel Pipe for High-Temperature Service

Table 1202.4Table 1302.3

A 126—04

Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings

Table 1202.5

A 254—97 (2007)

Specification for Copper Brazed Steel Tubing

Table 1202.4Table 1302.3

A 420/A 420M—07

Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-Temperature Service

Table 1202.5

A 539—99

Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines

Table 1302.3

B 32—08

Specification for Solder Metal

1203.3.3

B 42—02e01

Specification for Seamless Copper Pipe, Standard Sizes

513.13.11107.5.2Table 1202.4Table 1302.3

B 43—98(2004)

Specification for Seamless Red Brass Pipe, Standard Sizes

513.13.11107.5.2Table 1202.4Table 1302.3

B 68—02

Specification for Seamless Copper Tube, Bright Annealed

513.13.1

B 75—02

Specification for Seamless Copper Tube

Table 1202.4Table 1302.3

B 88—03

Specification for Seamless Copper Water Tube

513.13.11107.5.3Table 1202.4Table 1302.3

B 135—08a

Specification for Seamless Brass Tube

Table 1202.4Table 1302.3

B 251—02e01

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

513.13.1Table 1202.4

B 280—08

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

513.13.11107.4.3Table 1302.3

B 302—07

Specification for Threadless Copper Pipe, Standard Sizes

Table 1202.4Table 1302.3

B 813—00(2009)

Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube

1203.3.3

C 315—07

Specification for Clay Flue Liners and Chimney Pots

801.16.1Table 803.10.4

C 411—05

Test Method for Hot-surface Performance of High-temperature Thermal Insulation

604.3

D 56—05

Test Method for Flash Point by Tag Closed Tester

202

D 93—08

Test Method for Flash Point of Pensky-Martens Closed Cup Tester

202

D 1527—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80

Table 1202.4

D 1693—08

Test Method for Environmental Stress-Cracking of Ethylene Plastics

Table 1202.4

D 1785—06

Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120

Table 1202.4

D 2235—04

Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings

1203.3.4

D 2241—05

Specification for Poly (Vinyl Chloride)(PVC) Pressure-rated Pipe (SDR-Series)

Table 1202.4

D 2282—99(2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)

Table 1202.4

D 2412—02(2008)

Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading

603.8.3

D 2447—03

Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter

Table 1202.4

D 2466—06

Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5

D 2467—06

Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5

D 2468—96a

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40

Table 1202.5

D 2513—08b

Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings

Table 1202.4

D 2564—04e01

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

1203.3.4

D 2657—07

Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings

1203.15.1

D 2683—04

Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing

Table 1202.41203.15.1

D 2837—08

Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products

Table 1202.4

D 2846/D 2846M—09

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems

Table 1202.41203.3.4

D 2996—01(2007)e01

Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe

Table 1302.3

D 3035—08

Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

Table 1202.4

D 3278—96(2004)

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

D 3261—03

Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing

1203.15.1

D 3309—96a(2002)

Specification for Polybutylene (PB) Plastic Hot and Cold Water Distribution Systems

Table 1202.41203.10.1

D 3350—08

Specification for Polyethylene Plastics Pipe and Fittings Materials

Table 1202.4

E 84—09

Test Method for Surface Burning Characteristics of Building Materials

202510.8602.2.1602.2.1.5604.31204.1

E 119—08a

Test Method for Fire Tests of Building Construction and Materials

607.5.2607.5.5607.6.1607.2.1

E 136—09

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C

202

E 814—08b

Test Method for Fire Tests of Through-penetration Fire Stops

506.3.10.2506.3.10.3

E 1509—04

Specification for Room Heaters, Pellet Fuel-burning Type

904.1

E 2231—04

Standard Practice For Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics

604.31204.1

E 2336—04

Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems

506.3.6506.3.10.2

F 438—04

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table 1202.5

F 439—06

Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 1202.5

F 441/F 441M—02(2008)

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80

Table 1202.4

F 442/F 442M—99(2005)e1

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)

Table 1202.4

F 493—04

Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings

1203.3.4

F 876—08b

Specification for Crosslinked Polyethylene (PEX) Tubing

Table 1202.4

F 877—07

Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems

Table 1202.4Table 1202.5

F 1055—98(2006)

Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Tubing

Table 1202.41203.15.2

F 1281—07

Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe

Table 1202.4

F 1282—06

Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe

Table 1202.4

F 1476—07

Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications

1203.3.7

F 1807—08

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR 9 Cross-linked Polyethylene (PEX) Tubing

Table 1202.5

F 1924—05

Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing

1203.15.3

F 1974—08

Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe

Table 1202.5

F 2159—05

Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR 9 Cross-linked Polyethylene (PEX) Tubing

Table 1202.5

F 2389—07e1

Specification for Pressure-rated Polypropylene Piping Systems

Table 1202.4Table 1202.5

F 2623—08

Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1

Table 1202.4

F 2735—08a

Standard Specification for Plastic Insert Fittings for SDR 9 Cross-linked Polyethylene (PEX) and Raised Temperature (PE-RT) Tubing

Table 1202.5

F 2769—09

Polyethylene of Raised Temperature (PE-RT) Plastic Hot and Cold-water Tubing and Distribution Systems

Table 1202.4

AWS

American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami FL 33135
Standard
reference
number
TitleReferenced
in code
section number

A5.8—2004

Specifications for Filler Metals for Brazing and Braze Welding

1203.3.11303.3.1

AWWA

American Water Work Association
6666 West Quincy Avenue
Denver CO 80235
Standard
reference
number
TitleReferenced
in code
section number

C110/A21.10—03

Standard for Ductile Iron & Gray Iron Fittings, 2 inches Through 48 inches for Water

Table 1202.5

C115/A21.15—99

Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges

Table 1202.4

C151/A21.51—02

Standard for Ductile-iron Pipe, Centrifugally Cast for Water

Table 1202.4

C153/A21.53—00

Standard for Ductile-iron Compact Fittings for Water Service

Table 1202.5

CSA

Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario Canada L4W 5N6
Standard
reference
number
TitleReferenced
in code
section number

B137.9—05

Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems

Table 1202.4

B137.10—05

Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems

Table 1202.4

ANSI CSA America FC1—03

Stationary Fuel Cell Power Systems

924.1

DOL

Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number

29 CFR Part 1910.1000 (2009)

Air Contaminants

502.6

29 CFR Part 1910.1025 (2009)

Toxic and Hazardous Substances

502.19

FS

Federal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington DC 20407
Standard
reference
number
TitleReferenced
in code
section number

WW-P-325B (1976)

Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325

Table 1202.4

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

IBC—12

International Building Code®

201.3202301.12301.12301.14301.15302.1302.2304.7304.10308.8308.10401.4401.6406.1502.10502.10.1504.2506.3.3506.3.10506.3.12.2506.4.1509.1510.6510.6.3510.6.2510.7511.1.5513.1513.2513.3513.4.3513.5513.5.2513.5.2.1513.6.2513.10.5513.12513.12.2513.20602.2.1.5.1602.2.1.5.2602.3603.1603.10604.5.4607.1.1607.3.2.1607.5.1607.5.2607.5.3607.5.4607.5.4.1607.5.5607.5.5.1607.6607.6.2701.4.1701.4.2801.3801.16.1801.18.4902.1908.3908.4910.3925.11004.61105.11206.41402.41402.4.1

IFC—12

International Fire Code®

201.3310.1311.1502.4502.5502.7.2502.8.1502.9.5502.9.5.2502.9.5.3502.9.8.2502.9.8.3502.9.8.5502.9.8.6502.10502.10.3502.16.2509.1510.2.1510.2.2510.4511.1.1513.12.3513.15513.16513.17513.18513.19513.20.2513.20.3606.2.1908.71101.91105.31105.91106.51106.61301.11301.2

IPC—12

International Plumbing Code®

201.3301.8512.2908.51002.11002.21002.31005.21006.61008.21009.31101.41201.11206.21206.31401.2

IIAR

International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington VA 22201
Standard
reference
number
TitleReferenced
in code
section number

2—99 (with Addendum A—2005)

Addendum A to Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems

1101.6

MSS

Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna VA 22180
Standard
reference
number
TitleReferenced
in code
section number

SP-69—2002

Pipe Hangers and Supports-Selection and Application

305.4

NAIMA

North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria VA 22314
Standard
reference
number
TitleReferenced
in code
section number

AH116—09

Fibrous Glass Duct Construction Standards

603.5603.9

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
Standard
reference
number
TitleReferenced
in code
section number

30A—12

Code for Motor Fuel-dispensing Facilities and Repair Garages

304.6

31—11

Installation of Oil-burning Equipment

801.2.1801.18.1801.18.2920.2922.11308.1

37—10

Stationary Combustion Engines and Gas Turbines

915.1915.2

58—11

Liquefied Petroleum Gas Code

502.9.10

69—08

Explosion Prevention Systems

510.8.3

70—11

National Electrical Code

301.7306.3.1306.4.1511.1.1513.11513.12.1602.2.1.11106.31106.4

72—10

National Fire Alarm Code

606.3

82—09

Incinerators and Waste and Linen Handling Systems and Equipment

601.1

91—10

Exhaust Systems for Air Conveying of Vapors, Gases, and Noncombustible Particulate Solids

502.9.5.1502.17

92B—09

Smoke Management Systems in Malls, Atria and Large Spaces

513.8

96—08

Standard for Ventilation Control and Fire Protection Cooking Operations

507.2

262—11

Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces

602.2.1.1

704—12

Identification of the Hazards of Materials for Emergency Response

502.8.4Table 1103.1510.1

853—10

Installation of Stationary Fuel Power Plants

924.1

8501—97

Single Burner Boiler Operation

1004.1

8502—99

Prevention of Furnace Explosions/Implosions in Multiple Burner Boiler-furnaces

1004.1

8504—96

Atmospheric Fluidized-bed Boiler Operation

1004.1

SMACNA

Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly VA 20151-1209
Standard
reference
number
TitleReferenced
in code
section number

SMACNA/ANSI—2005

HVAC Duct Construction Standards-Metal and Flexible (2005)

603.4603.9

SMACNA—10

Fibrous Glass Duct Construction Standards

603.5603.9

UL

Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number

17—2008

Vent or Chimney Connector Dampers for Oil-fired Appliances

803.6

103—01

Factory-built Chimneys, Residential Type and Building Heating Appliance—with Revisions through March 2010

805.2

127—08

Factory-built Fireplaces—with Revisions through January 2010

805.3903.1903.3

174—04

Household Electric Storage Tank Water Heaters—with Revisions through May 2006

1002.1

180—03

Liquid-level Indicating Gauges for Oil Burner Fuels—with Revisions through March 2007

1306.4

181—05

Factory-made Air Ducts and Air Connectors—with Revisions through October 2008

512.2603.5603.6.1603.6.2604.13

181A—05

Closure Systems for Use with Rigid Air Ducts and Air Connectors— with Revisions through February 2008

603.9

181B—05

Closure Systems for Use with Flexible Air Ducts and Air Connectors— with Revisions through February 2008

603.9

207—2009

Refrigerant-containing Components and Accessories, Nonelectrical

1101.2

263—2003

Standard for Fire Test of Building Construction and Materials— with Revisions through October 2007

607.5.2607.5.5607.6.1

268—2009

Smoke Detectors for Fire Prevention Signaling

606.1

268A—2008

Smoke Detectors for Duct Application—with Revisions through September 2009

606.1

343—2008

Pumps for Oil-Burning Appliances

1302.7

378—06

Draft Equipment

804.3804.3.8

391—2006

Solid-fuel and Combination-fuel Central and Supplementary Furnaces— with Revisions through March 2010

918.1

412—04

Refrigeration Unit Coolers—with Revisions through January 2009

1101.2

471—06

Commercial Refrigerators and Freezers—with Revisions through October 2008

1101.2

499—05

Electric Heating Appliances—with Revisions through August 2008

912.1923.1

508—99

Industrial Control Equipment—with Revisions through September 2008

307.2.3

536—97

Flexible Metallic Hose—with Revisions through June 2003

1302.8

555—06

Fire Dampers—with Revisions through May 2010

607.3

555C—06

Ceiling Dampers—with Revisions through May 2010

607.3.1

555S—99

Smoke Dampers—with Revisions through May 2010

607.3.1

586—2009

High-Efficiency, Particulate, Air Filter Units

605.2

641—95

Type L Low-temperature Venting Systems—with Revisions through July 2009

802.1

710—95

Exhaust Hoods for Commercial Cooking Equipment—with Revisions through December 2009

507.1

710B—04

Recirculating Systems—with Revisions through April 2006

507.1

723—2008

Standard for Test for Surface Burning Characteristics of Building Materials

510.8602.2.1602.2.1.5604.31204.1

726—95

Oil-fired Boiler Assemblies—with Revisions through April 2010

916.11004.1

727—06

Oil-fired Central Furnaces

918.1

729—03

Oil-fired Floor Furnaces—with Revisions through April 2010

910.1

730—03

Oil-fired Wall Furnaces—with Revisions through April 2010

909.1

731—95

Oil-fired Unit Heaters—with Revisions through April 2010

920.1

732—95

Oil-fired Storage Tank Water Heaters—with Revisions through April 2010

1002.1

737—2007

Fireplace Stoves—with Revisions through January 2010

905.1

762—2010

Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances

506.5.1

791—06

Residential Incinerators—with Revisions through April 2010

907.1

834—04

Heating, Water Supply and Power Boilers Electric—with Revisions through December 2009

1004.1

842—07

Valves for Flammable Fluids

1307.1

858—05

Household Electric Ranges—with Revisions through May 2010

917.1

867—00

Electrostatic Air Cleaners—with Revisions through February 2010

605.2

875—09

Electric Dry Bath Heater—with Revisions through October 2009

914.2

896—93

Oil-burning Stoves—with Revisions through May 2010

917.1922.1

900—04

Air Filter Units—with Revisions through November 2009

605.2

923—2008

Microwave Cooking Appliances—with Revisions through June 2010

914.2

907—94

Fireplace Accessories—with Revisions through July 2006

901.4

959—01

Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2010

805.5

1046—00

Grease Filters for Exhaust Ducts

507.11

1240—05

Electric Commercial Clothes—Drying Equipment—with Revisions through October 2009

913.1

1261—01

Electric Water Heaters for Pools and Tubs—with Revisions through May 2008

916.1

1453—04

Electric Booster and Commercial Storage Tank Water Heaters— with Revisions through December 2009

1002.1

1479—03

Fire Tests of Through-penetration Firestops—with Revisions through April 2007

506.3.10.2506.3.10.3

1482—2010

Solid-fuel Type Room Heaters

905.1

1618—09

Wall Protectors, Floor Protectors and Hearth Extensions

308.5903.2905.3

1777—2007

Chimney Liners—with Revisions through July 2009

801.16.1801.18.4

1812—2009

Standard for Ducted Heat Recovery Ventilators—with Revisions through June 2010

927.1

1815—2009

Standard for Nonducted Heat Recovery

927.2

1820—04

Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics— with Revisions through February 2009

602.2.1.3

1887—04

Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics— with Revisions through February 2009

602.2.1.2

1978—05

Grease Ducts—with Revisions through June 2009

506.3.2

1995—05

Heating and Cooling Equipment—with Revisions through July 2009

911.1918.1918.31101.2

1996—04

Electric Duct Heaters—with Revisions through December 2006

911.1

2024—2008

Standard for Safety Optical-Fiber and Communications Cable Raceway

602.2.1.1

2043—2008

Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories Installed in Air-handling Spaces

602.2.1.4.2

2158—97

Electric Clothes Dryers—with Revisions through March 2009

504.6.3913.1

2158A—2006

Outline of Investigation for Clothes Dryer Transition Duct

504.6.3

2162—01

Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type

917.1

2200—98

Stationery Engine Generator Assemblies—with Revisions through December 2009

915.1

2221—01

Tests of Fire Resistive Grease Duct Enclosure Assemblies

506.3.10.3

2518—02

Air Dispersion System Materials

603.17

2523—09

Solid Fuel-fired Hydronic Heating Appliances

1002.11004.1