This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section C106.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL 60173-4268
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A C440—11

North American Fenestration Standard/ Specifications for Windows, Doors and Unit Skylights

Table C402.4.3

AHAM

Association of Home Appliance Manufacturers
1111 19th Street, NW, Suite 402
Washington DC 20036
Standard
reference
number
TitleReferenced
in code
section number

ANSI/AHAM RAC-1—2008

Room Air Conditioners

Table C403.2.3(3)

AHRI

Air Conditioning, Heating, and Refrigeration Institute
4100 North Fairfax Drive
Suite 200
Arlington VA 22203
Standard
reference
number
TitleReferenced
in code
section number

ISO/AHRI/ASHRAE 13256-1 (2005)

Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps

Table C403.2.3(2)

ISO/AHRI/ASHRAE 13256-2 (1998)

Water-source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-water and Brine-to-water Heat Pumps

Table C403.2.3(2)

210/240—08

Unitary Air Conditioning and Air-source Heat Pump Equipment

Table C403.2.3(1)Table C403.2.3(2)

310/380—04

Standard for Packaged Terminal Air Conditioners and Heat Pumps

Table C403.2.3(3)

340/360—2007

Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment

Table C403.2.3(1)Table C403.2.3(2)

365—09

Commercial and Industrial Unitary Air-conditioning Condensing Units

Table C403.2.3(1)Table C403.2.3(6)

390—03

Performance Rating of Single Package Vertical Air Conditioners and Heat Pumps

Table C403.2.3(3)

400—01

Liquid to Liquid Heat Exchangers with Addendum 2

Table C403.2.3(9)

440—08

Room Fan Coil

C403.2.8

460—05

Performance Rating Remote Mechanical Draft Air-cooled Refrigerant Condensers

Table C403.2.3(8)

550/590—03

Water Chilling Packages Using the Vapor Compression Cycle—with Addenda

C403.2.3.1Table C403.2.3(7)Table C406.2(6)

560—00

Absorption Water Chilling and Water-heating Packages

Table C403.2.3(7)

1160—08

Performance Rating of Heat Pump Pool Heaters

Table C404.2

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL 60004-1806
Standard
reference
number
TitleReferenced
in code
section number

500D—10

Laboratory Methods for Testing Dampers for Rating

C402.4.5.1C402.4.5.2

ANSI

American National Standards Institute
25 West 43rd Street
Fourth Floor
New York NY 10036
Standard
reference
number
TitleReferenced
in code
section number

Z21.10.3/CSA 4.3—04

Gas Water Heaters, Volume III—Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous

Table C404.2

Z21.47/CSA 2.3—06

Gas-fired Central Furnaces

Table C403.2.3(4)Table C406.2.(4)

Z83.8/CSA 2.6—09

Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces

Table C403.2.3(4)Table C406.2.(4)

ASHRAE

American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta GA 30329-2305
Standard
reference
number
TitleReferenced
in code
section number

ANSI/ASHRAE/ACCA Standard 183—2007

Peak Cooling and Heating Load Calculations in Buildings, Except Low-rise Residential Buildings

C403.2.1

ASHRAE—2004

ASHRAE HVAC Systems and Equipment Handbook—2004

C403.2.1

ISO/AHRI/ASHRAE 13256-1 (2005)

Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps

Table C403.2.3(2)

ISO/AHRI/ASHRAE 13256-2 (1998)

Water-source Heat Pumps—Testing and Rating for Performance— Part 2: Water-to-water and Brine-to-water Heat Pumps

Table C403.2.3(2)

90.1—2010

Energy Standard for Buildings Except Low-rise Residential Buildings

C401.2C401.2.1C402.1.1Table C402.1.2Table C402.2Table C407.6.1

119—88 (RA 2004)

Air Leakage Performance for Detached Single-family Residential Buildings

Table C405.5.2(1)

140—2010

Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs

C407.6.1

146—2006

Testing and Rating Pool Heaters

Table C404.2

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428-2859
Standard
reference
number
TitleReferenced
in code
section number

C 90—08

Specification for Load-bearing Concrete Masonry Units

Table C402.2

C 1371—04

Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers

Table C402.2.1.1

C 1549—04

Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using A Portable Solar Reflectometer

Table C405.2.1.1

D 1003—07e1

Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics

C402.3.2.2

E 283—04

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

Table C402.2.1.1C402.4.1.2.2Table C402.4.3C402.4.4C402.4.8

E 408—71(2002)

Test Methods for Total Normal Emittance of Surfaces Using Inspection-meter Techniques

Table C402.2.1.1

E 779—03

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

C402.4.1.2.3

E 903—96

Standard Test Method Solar Absorptance, Reflectance and Transmittance of Materials Using Integrating Spheres (Withdrawn 2005)

Table C402.2.1.1

E 1677—05

Standard Specification for an Air-retarder (AR) Material or System for Low-rise Framed Building Walls

C402.4.1.2.2

E 1918—97

Standard Test Method for Measuring Solar Reflectance of Horizontal or Low-sloped Surfaces in the Field

Table C402.2.1.1

E 1980—(2001)

Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-sloped Opaque Surfaces

Table C402.2.1.1

E 2178—03

Standard Test Method for Air Permanence of Building Materials

C402.4.1.2.1

E 2357—05

Standard Test Method for Determining Air Leakage of Air Barriers Assemblies

C404.1.2.2

CSA

Canadian Standards Association
5060 Spectrum Way
Mississauga
Ontario Canada L4W 5N6
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A440—11

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

Table C402.4.3

CTI

Cooling Technology Institute
2611 FM 1960 West, Suite A-101
Houston TX 77068
Standard
reference
number
TitleReferenced
in code
section number

ATC 105 (00)

Acceptance Test Code for Water Cooling Tower

Table C403.2.3(8)

STD 201—09

Standard for Certification of Water Cooling Towers Thermal Performances

Table C403.2.3(8)

DASMA

Door and Access Systems Manufacturers Association
1300 Sumner Avenue
Cleveland OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number

105—92 (R2004)

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors

Table C402.4.3

DOE

U.S. Department of Energy
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number

10 CFR, Part 430—1998

Energy Conservation Program for Consumer Products: Test Procedures and Certification and Enforcement Requirement for Plumbing Products; and Certification and Enforcement Requirements for Residential Appliances; Final Rule

Table C403.2.3(4)Table C403.2.3(5)Table C404.2Table C406.2(4)Table C406.2(5)

10 CFR, Part 430, Subpart B, Appendix N—1998

Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

C202

10 CFR, Part 431—2004

Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures and Efficiency Standards; Final Rules

Table C403.2.3(5)Table C406.2(5)

NAECA 87—(88)

National Appliance Energy Conservation Act 1987 [(Public Law 100-12 (with Amendments of 1988-P.L. 100-357)]

Tables C403.2.3(1)(2)(4)

ICC

International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

IMC—12

International Mechanical Code®

C403.2.5C403.2.5.1C403.2.6C403.2.7C403.2.7.1C403.2.7.1.1C403.2.7.1.2C403.2.7.1.3C403.4.5C408.2.2.1

IESNA

Illuminating Engineering Society of North America
120 Wall Street, 17th Floor
New York NY 10005-4001
Standard
reference
number
TitleReferenced
in code
section number

ANSI/ASHRAE/IESNA 90.1—2010

Energy Standard for Buildings, Except Low-rise Residential Buildings

C401.2C401.2.1C402.1.1Table C402.1.2Table C402.2

ISO

International Organization for Standardization
1, rue de Varembe, Case postale 56, CH-1211
Geneva Switzerland
Standard
reference
number
TitleReferenced
in code
section number

ISO/AHRI/ASHRAE 13256-1 (2005)

Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps

C403.2.3(2)

ISO/AHRI/ASHRAE 13256-2 (1998)

Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-water and Brine-to-water Heat Pumps

C403.2.3(2)

NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD 20770
Standard
reference
number
TitleReferenced
in code
section number

100—2010

Procedure for Determining Fenestration Products U-factors

C303.1.2C402.2.1

200—2010

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

C303.1.3C402.3.1.1

400—2010

Procedure for Determining Fenestration Product Air Leakage

Table C402.4.3

SMACNA

Sheet Metal and Air Conditioning Contractors National Association, Inc.
4021 Lafayette Center Drive
Chantilly VA 20151-1209
Standard
reference
number
TitleReferenced
in code
section number

SMACNA—85

HVAC Air Duct Leakage Test Manual

C403.2.7.1.3

UL

Underwriters Laboratories
333 Pfingsten Road
Northbrook IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number

727—06

Oil-fired Central Furnaces—with Revisions through April 2010

Table C403.2.3(4)Table C406.2(4)

731—95

Oil-fired Unit Heaters—with Revisions through April 2010

Table C403.2.3(4)Table C406.2(4)

US-FTC

United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC 20580
Standard
reference
number
TitleReferenced
in code
section number

CFR Title 16 (May 31, 2005)

R-value Rule

C303.1.4

WDMA

Window and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines IL 60018
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A440—11

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

Table C402.4.3