This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.4.

AA

Aluminum Association
1525 Wilson Boulevard, Suite 600
Arlington VA 22209
Standard
reference
number
TitleReferenced
in code
section number

ADM1—2010

Aluminum Design Manual: Part 1—A Specification for Aluminum Structures

1604.3.5, 2002.1

ASM 35—00

Aluminum Sheet Metal Work in Building Construction (Fourth Edition)

2002.1

AAMA

American Architectural Manufacturers Association
1827 Waldon Office Square, Suite 550
Schaumburg IL 60173
Standard
reference
number
TitleReferenced
in code
section number

1402—86

Standard Specifications for Aluminum Siding, Soffit and Fascia

1404.5.1

AAMA/WDMA/CSA 101/I.S.2/A440—11

North American Fenestration Standard/Specifications for Windows, Doors and Skylights

1710.5.1, 2405.5

AF&PA

American Forest & Paper Association
1111 19th St, NW Suite 800
Washington DC 20036
Standard
reference
number
TitleReferenced
in code
section number

WCD No. 4—2003

Wood Construction Data—Plank and Beam Framing for Residential Buildings

2306.1.2

ANSI/AF&PA WFCM—2012

Wood Frame Construction Manual for One- and Two-Family Dwellings

1609.1.1, 1609.1.1.1, 2301.2, 2308.1, 2308.2.1

AF&PA—2012

Span Tables for Joists and Rafters

202, 2306.1.1, 2308.8, 2308.10.2, 2308.10.3

ANSI/AF&PA PWF—2007

Permanent Wood Foundation Design Specification

1805.2, 1807.1.4, 2304.9.5.2

ANSI/AF&PA SDPWS—2008

Special Design Provisions for Wind and Seismic

202, 2305.1, 2305.2, 2305.3, 2306.2, 2306.3, Table 2306.3(1), Table 2306.3(3), 2307.1

AISC

American Institute of Steel
Construction One East Wacker Drive, Suite 700
Chicago IL 60601-18021
Standard
reference
number
TitleReferenced
in code
section number

ANSI/AISC 341—10

Seismic Provisions for Structural Steel Buildings

1613.4.1, 1705.11.1, 1705.12.2, 2205.2.1, 2205.2.2, 2206.2

ANSI/AISC 360—10

Specification for Structural Steel Buildings

722.5.2.2.1, 1604.3.3, 1705.2.1, 2203.1, 2203.2, 2205.1, 2205.2.1, 2206.1

AISI

American Iron and Steel Institute
1140 Connecticut Avenue, 705
Suite 705
Washington DC 20036
Standard
reference
number
TitleReferenced
in code
section number

AISI S100—07/S2—10

North American Specification for the Design of Cold-formed Steel Structural Members, with Supplement 2, dated 2010

1604.3.3, 1905.1.9, 2203.1, 2203.2, 2210.1, 2210.2, 2211.2, 2211.4, 2211.6

AISI S110—07/S1—09

Standard for Seismic Design of Cold-formed Steel Structural Systems—Special Bolted Moment Frames, with Supplement 1, dated 2009

2210.2

AISI S200—07

North American Standard for Cold-formed Steel Framing-General Provisions

2203.1, 2203.2, 2211.1

AISI S210—07

North American Standard for Cold-formed Steel Framing-Floor and Roof System Design

2211.5

AISI S211—07

North American Standard for Cold-formed Steel Framing-Wall Stud Design

2211.4

AISI S212—07

North American Standard for Cold-formed Steel Framing-Header Design

2211.2

AISI S213—07/S1—09

North American Standard for Cold-formed Steel Framing-Lateral Design, with Supplement 1, dated 2009

2211.6

AISI S214—07/S2—08

North American Standard for Cold-formed Steel Framing-Truss Design, with Supplement 2, dated 2008

2211.3, 2211.3.1, 2211.3.2

AISI S230—07/S2—08

Standard for Cold-formed Steel Framing-Prescriptive Method for One- and Two-family Dwellings, with Supplement 2, dated 2008

1609.1.1, 1609.1.1.1, 2211.7

AITC

American Institute of Timber Construction
Suite 140
7012 S. Revere Parkway
Englewood CO 80112
Standard
reference
number
TitleReferenced
in code
section number

AITC Technical Note 7—96

Calculation of Fire Resistance of Glued Laminated Timbers

722.6.3.3

AITC 104—03

Typical Construction Details

2306.1

AITC 110—01

Standard Appearance Grades for Structural Glued Laminated Timber

2306.1

AITC 113—10

Standard for Dimensions of Structural Glued Laminated Timber

2306.1

AITC 117—10

Standard Specifications for Structural Glued Laminated Timber of Softwood Species

2306.1

AITC 119—96

Standard Specifications for Structural Glued Laminated Timber of Hardwood Species

2306.1

ANSI/AITC A 190.1—07

Structural Glued Laminated Timber

2303.1.3, 2306.1

AITC 200—09

Manufacturing Quality Control Systems Manual for Structural Glued Laminated Timber

2306.1

ALI

Automotive Lift Institute
P.O. Box 85
Courtland NY 13045
Standard
reference
number
TitleReferenced
in code
section number

ALI ALCTV—2006

Standard for Automotive Lifts—Safety Requirements for Construction, Testing and Validation (ANSI)

3001.2

AMCA

Air Movement and Control Association International
30 West University Drive
Arlington Heights IL 60004
Standard
reference
number
TitleReferenced
in code
section number

540—08

Test Method for Louvers Impacted by Wind Borne Debris

1609.1.2.1

ANSI

American National Standards Institute
25 West 43rd Street, Fourth Floor
New York NY 10036
Standard
reference
number
TitleReferenced
in code
section number

A13.1—96 (Reaffirmed 2002)

Scheme for the Identification of Piping Systems

415.10.6.5

A108.1A—99

Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar

2103.11

A108.1B—99

Installation of Ceramic Tile, quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex-portland Mortar

2103.11

A108.4—99

Installation of Ceramic Tile with Organic Adhesives or Water-cleanable Tile-setting Epoxy Adhesive

2103.11.6

A108.5—99

Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar

2103.11.1, 2103.11.2

A108.6—99

Installation of Ceramic Tile with Chemical-resistant, Water Cleanable Tile-setting and -grouting Epoxy

2103.11.3

A108.8—99

Installation of Ceramic Tile with Chemical-resistant Furan Resin Mortar and Grout

2103.11.4

A108.9—99

Installation of Ceramic Tile with Modified Epoxy Emulsion Mortar/Grout

2103.11.5

A108.10—99

Installation of Grout in Tilework

2103.11.7

A118.1—99

American National Standard Specifications for Dry-set Portland Cement Mortar

2103.11.1

A118.3—99

American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy and Water Cleanable Tile-setting Epoxy Adhesive

2103.11.3

A118.4—99

American National Standard Specifications for Latex-portland Cement Mortar

2103.11.2

A118.5—99

American National Standard Specifications for Chemical Resistant Furan Mortar and Grouts for Tile Installation

2103.11.4

A118.6—99

American National Standard Specifications for Cement Grouts for Tile Installation

2103.11.7

A118.8—99

American National Standard Specifications for Modified Epoxy Emulsion Mortar/Grout

2103.11.5

A136.1—99

American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile

2103.11.6

A137.1—08

American National Standard Specifications for Ceramic Tile

202, 2103.6

Z 97.1—09

Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test

2406.1.2, 2406.2, Table 2406.2(2), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1, 2408.3, 2409.1, 2409.2, 2409.3.1

APA

APA - Engineered Wood Association
7011 South 19th
Tacoma WA 98466
Standard
reference
number
TitleReferenced
in code
section number

ANSI/APA PRP 210—08

Standard for Performance-Rated Engineered Wood Siding

2303.1.4, 2304.6.2, 2306.3, Table 2306.3(1)

APA PDS—04

Panel Design Specification

2306.1

APA PDS Supplement 1—90

Design and Fabrication of Plywood Curved Panels (revised 1995)

2306.1

APA PDS Supplement 2—92

Design and Fabrication of Plywood-lumber Beams (revised 1998)

2306.1

APA PDS Supplement 3—90

Design and Fabrication of Plywood Stressed-skin Panels (revised 1996)

2306.1

APA PDS Supplement 4—90

Design and Fabrication of Plywood Sandwich Panels (revised 1993)

2306.1

APA PDS Supplement 5—08

Design and Fabrication of All-plywood Beams (revised 2008)

2306.1

EWS R540—02

Builders Tips: Proper Storage and Handling of Glulam Beams

2306.1

EWS S475—01

Glued Laminated Beam Design Tables

2306.1

EWS S560—03

Field Notching and Drilling of Glued Laminated Timber Beams

2306.1

EWS T300—05

Glulam Connection Details

2306.1

EWS X440—03

Product Guide-Glulam

2306.1

EWS X450—01

Glulam in Residential Construction-Western Edition

2306.1

API

American Petroleum Institute
1220 L. Street, NW
Washington DC 20005
Standard
reference
number
TitleReferenced
in code
section number

650—09

Welded Steel Tanks for Oil Storage

426.2

653—09

Tank Inspection, Repair, Alteration and Reconstruction

426.4, 426.5

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue
Alexandria VA 22314
Standard
reference
number
TitleReferenced
in code
section number

ANSI/APSP 7—06

Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins

3109.5

ASABE

American Society of Agricultural and Biological Engineers
2950 Niles Road
St. Joseph MI 49085
Standard
reference
number
TitleReferenced
in code
section number

EP 484.2 June 1998 (R2008)

Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings

2306.1

EP 486.1 Dec 1999 (R2005)

Shallow-post Foundation Design

2306.1

EP 559 1997 Dec 1996 (R2008)

Design Requirements and Bending Properties for Mechanically Laminated Columns

2306.1

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400
Standard
reference
number
TitleReferenced
in code
section number

8—02

Standard Specification for the Design of Cold-formed Stainless Steel Structural Members

1604.3.3, 2210.1, 2210.2

1910

Structural Applications of Steel Cables for Buildings

2208.1, 2208.2

24—05

Flood Resistant Design and Construction

1203.3.2, 1612.4, 1612.5, 3001.2, G103.1, G401.3, G401.4

29—05

Standard Calculation Methods for Structural Fire Protection

722.1

32—01

Design and Construction of Frost Protected Shallow Foundations

1809.5

ASME

American Society of Mechanical Engineers
Three Park Avenue
New York NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number

ASME/A17.1 2007/CSA B44—07

Safety Code for Elevators and Escalators — with A17.1a/CSA B44a-08 Addenda

907.3.3, 911.1.5, 1007.4, 1607.9.1, 3001.2, 3001.4, 3002.5, 3003.2, 3007.1, 3007.2, 3008.2, 3008.2.1, 3008.7.6, 3008.8.1, 3411.8.2

A17.1—2010/CSA B44—10

Safety Code for Elevators and Escalators

907.3.3, 911.1.5, 1007.4, 1607.9.1, 3001.2, 3001.4, 3002.5, 3003.2, 3007.1, 3007.2, 3008.2, 3008.2.1, 3008.7.6, 3008.8.1

A18.1—2011

Safety Standard for Platform Lifts and Stairway Chairlifts

1109.8, 2702.2.6

A90.1—09

Safety Standard for Belt Manlifts

3001.2

B16.18—2001 (Reaffirmed 2005)

Cast Copper Alloy Solder Joint Pressure Fittings

909.13.1

B16.22—2001 (Reaffirmed 2005)

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

909.13.1

B20.1—2009

Safety Standard for Conveyors and Related Equipment

3005.3

B31.3—2004

Process Piping

415.10.6

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428-2959
Standard
reference
number
TitleReferenced
in code
section number

A 36/A 36M—08

Specification for Carbon Structural Steel

1810.3.2.3

A 153/A 153M—05

Specification for Zinc Coating (Hot-dip) on Iron and Steel Hardware

2304.9.5

A 240/A 240M—09a

Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications

Table 1507.4.3(1)

A 252—98 (2007)

Specification for Welded and Seamless Steel Pipe Piles

1810.3.2.3

A 283/A 283M—03(2007)

Specification for Low and Intermediate Tensile Strength Carbon Steel Plates

1810.3.2.3

A 307—07b

Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength

1908.1

A 416/A 416M—06

Specification for Steel Strand, Uncoated Seven-wire for Prestressed Concrete

1810.3.2.2

A 463/A 463M—06

Standard Specification for Steel Sheet, Aluminum-coated, by the Hot-dip Process

Table 1507.4.3(2)

A 572/A 572M—07

Specification for High-strength Low-alloy Columbium-vanadium Structural Steel

1810.3.2.3

A 588/A 588M—05

Specification for High-strength Low-alloy Structural Steel with 50 ksi (345 MPa) Minimum Yield Point with Atmospheric Corrosion Resistance

1810.3.2.3

A 615/A 615M—09

Specification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement

1705.12.1, 1810.3.10.2

A 653/A 653M—08

Specification for Steel Sheet, Zinc-coated Galvanized or Zinc-iron Alloy-coated Galvannealed by the Hot-dip Process

Table 1507.4.3(1), Table 1507.4.3(2), 2304.9.5.1

A 690/A 690M—07

Standard Specification for High-strength Low-alloy Nickel, Copper, Phosphorus Steel H-piles and Sheet Piling with Atmospheric Corrosion Resistance for Use in Marine Environments

1810.3.2.3

A 706/A 706M—09

Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement

Table 1705.2.2, 1705.3.1, 2107.4, 2108.3

A 722/A 722M—07

Specification for Uncoated High-strength Steel Bar for Prestressing Concrete

1810.3.10.2

A 755/A 755M—03(2008)

Specification for Steel Sheet, Metallic-coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products

Table 1507.4.3(1), Table 1507.4.3(2)

A 792/A 792M—08

Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process

Table 1507.4.3(1), Table 1507.4.3(2)

A 875/A 875M—06

Standard Specification for Steel Sheet Zinc-5 percent, Aluminum Alloy-coated by the Hot-dip Process

Table 1507.4.3(2)

A 913/A 913M—07

Specification for High-strength Low-alloy Steel Shapes of Structural Quality, Produced by Quenching and Self-tempering Process (QST)

1810.3.2.3

A 924/A 924M—08a

Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process

Table 1507.4.3(1)

A 992/A 992M—06a

Standard Specification for Structural Shapes

1810.3.2.3

B 42—02e01

Specification for Seamless Copper Pipe, Standard Sizes

909.13.1

B 43—98(2004)

Specification for Seamless Red Brass Pipe, Standard Sizes

909.13.1

B 68—02

Specification for Seamless Copper Tube, Bright Annealed (Metric)

909.13.1

B 88—03

Specification for Seamless Copper Water Tube

909.13.1

B 101—07

Specification for Lead-coated Copper Sheet and Strip for Building Construction

1404.5.3, Table 1507.2.9.2, Table 1507.4.3(1)

B 209—07

Specification for Aluminum and Aluminum Alloy Steel and Plate

Table 1507.4.3(1)

B 251—02e01

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

909.13.1

B 280—03

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

909.13.1

B 370—09

Specification for Cold-rolled Copper Sheet and Strip for Building Construction

1404.5.2, Table 1507.2.9.2, Table 1507.4.3(1)

B 695—04

Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building Construction

2304.9.5.1, 2304.9.5.3

C 5—03

Specification for Quicklime for Structural Purposes

Table 2507.2

C 22/C 22M—00(2005) e01

Specification for Gypsum

Table 2506.2

C 27—98(2008)

Specification for Standard Classification of Fireclay and High-alumina Refractory Brick

2111.5

C 28/C 28M—00 (2005)

Specification for Gypsum Plasters

Table 2507.2

C 31/C 31M—08b

Practice for Making and Curing Concrete Test Specimens in the Field

Table 1705.3

C 33/C33M—08

Specification for Concrete Aggregates

722.3.1.4, 722.4.1.1.3

C 34—03

Specification for Structural Clay Load-bearing Wall Tile

2103.2

C 35—01(2005)

Specification for Inorganic Aggregates for Use in Gypsum Plaster

Table 2507.2

C 55—06e01

Specification for Concrete Building Brick

Table 722.3.2, 2103.1, 2105.2.2.1.2

C 56—05

Specification for Structural Clay Nonload Bearing Tile

2103.2

C 59/C 59M—00 (2006)

Specification for Gypsum Casting and Molding Plaster

Table 2507.2

C 61/C 61M—00 (2006)

Specification for Gypsum Keene's Cement

Table 2507.2

C 62—08

Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)

1807.1.6.3, 2203.2, 2105.2.2.1.1

C 67—08

Test Methods of Sampling and Testing Brick and Structural Clay Tile

721.4.1.1.1, 2109.3.1.1

C 73—05

Specification for Calcium Silicate Face Brick (Sand-lime Brick)

Table 722.3.2, 2103.1

C 90—08

Specification for Loadbearing Concrete Masonry Units

Table 722.3.2, 1807.1.6.3, 2103.1

C 91—05

Specification for Masonry Cement

Table 2507.2

C 94/C 94M—09

Specification for Ready-mixed Concrete

110.3.1

C 126—99 (2005)

Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick and Solid Masonry Units

2103.2

C 140—08a

Test Method Sampling and Testing Concrete Masonry Units and Related Units

722.3.1.2

C 150—07

Specification for Portland Cement

Table 2507.2

C 172—08

Practice for Sampling Freshly Mixed Concrete

Table 1705.3

C 199—84 (2005)

Test Method for Pier Test for Refractory Mortars

2111.5, 2111.8, 2113.12

C 206—03

Specification for Finishing Hydrated Lime

Table 2507.2

C 208—08a

Specification for Cellulosic Fiber Insulating Board

Table 1508.2, 2303.1.5

C 212—00 (2006)

Specification for Structural Clay Facing Tile

2103.2

C 216—07a

Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)

1807.1.6.3, 2103.2, 2105.2.2.1.1

C 270—08a

Specification for Mortar for Unit Masonry

2103.9

C 315—07

Specification for Clay Flue Liners and Chimney Pots

2111.8, 2113.11.1, Table 2113.16(1)

C 317/C 317M—00 (2005)

Specification for Gypsum Concrete

1911.1

C 330—05

Specification for Lightweight Aggregates for Structural Concrete

202

C 406—06e01

Specification for Roofing Slate

1507.7.5

C 472—99 (2004)

Specification for Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete

Table 2506.2

C 473—07

Test Method for Physical Testing of Gypsum Panel Products

Table 2506.2

C 474—05

Test Methods for Joint Treatment Materials for Gypsum Board Construction

Table 2506.2

C 475/C 475M—02 (2007)

Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard

Table 2506.2

C 503—08a

Specification for Marble Dimension Stone (Exterior)

2103.4

C 514—04

Specification for Nails for the Application of Gypsum Board

Table 721.1(2), Table 721.1(3), Table 2306.7, Table 2506.2

C 516—08a

Specifications for Vermiculite Loose Fill Thermal Insulation

722.3.1.4, 722.4.1.1.3

C 547—07e1

Specification for Mineral Fiber Pipe Insulation

Table 721.1(2), Table 721.1(3)

C 549—06

Specification for Perlite Loose Fill Insulation

722.3.1.4, 722.4.1.1.3

C 552—07

Standard Specification for Cellular Glass Thermal Insulation

Table 1508.2

C 557—03e01

Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing

Table 2506.2

C 568—08a

Specification for Limestone Dimension Stone

2103.4

C 578—08b

Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation

Table 1508.2

C 587—04

Specification for Gypsum Veneer Plaster

Table 2507.2

C 595—08a

Specification for Blended Hydraulic Cements

Table 2507.2

C 615—03

Specification for Granite Dimension Stone

2103.4

C 616—08a

Specification for Quartz Dimension Stone

2103.4

C 629—08

Specification for Slate Dimension Stone

2103.4

C 631—09

Specification for Bonding Compounds for Interior Gypsum Plastering

Table 2507.2

C 635/C635M—07

Specification for the Manufacture, Performance and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings

808.1.1, 2506.2.1, H107.1.1

C 636/C 636M—08

Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels

808.1.1.1

C 645—08a

Specification for Nonstructural Steel Framing Members

Table 2506.2, Table 2507.2

C 652—09

Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)

1807.1.6.3, 2103.2, 2105.2.2.1.1

C 726—05e1

Standard Specification for Mineral Fiber Roof Insulation Board

Table 1508.2

C 728—05

Standard Specification for Perlite Thermal Insulation Board

Table 1508.2

C 744—08

Specification for Prefaced Concrete and Calcium Silicate Masonry Units

Table 722.3.2, 2103.1

C 754—08

Specification for Installation of Steel Framing Members to Receive Screw-attached Gypsum Panel Products

Table 2508.1, Table 2511.1.1

C 836—06

Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course

1507.15.2

C 840—08

Specification for Application and Finishing of Gypsum Board

Table 2508.1, 2509.2

C 841—03 (2008) e1

Specification for Installation of Interior Lathing and Furring

Table 2508.1, Table 2511.1.1

C 842—05

Specification for Application of Interior Gypsum Plaster

Table 2511.1.1, 2511.3, 2511.4

C 843—99 (2006)

Specification for Application of Gypsum Veneer Plaster

Table 2511.1.1

C 844—04

Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster

Table 2508.1

C 847—09

Specification for Metal Lath

Table 2507.2

C 887—05

Specification for Packaged, Dry Combined Materials for Surface Bonding Mortar

1805.2.2, 2103.10

C 897—05

Specification for Aggregate for Job-Mixed Portland Cement-based Plaster

Table 2507.2

C 920—08

Standard for Specification for Elastomeric Joint Sealants

Table 2506.2

C 926—06

Specification for Application of Portland Cement-based Plaster

2109.3.4.8, 2510.3, Table 2511.1.1, 2511.3, 2511.4, 2512.1, 2512.1.2, 2512.2, 2512.6, 2512.8.2, 2512.9, 2513.7

C 932—06

Specification for Surface-applied Bonding Compounds Agents for Exterior Plastering

Table 2507.2

C 933—07b

Specification for Welded Wire Lath

Table 2507.2

C 946—91 (2001)

Specification for Practice for Construction of Dry-stacked, Surface-bonded Walls

2103.10, 2109.2.2

C 954—07

Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 inch (0.84 mm) to 0.112 inch (2.84 mm) in Thickness

Table 2506.2, Table 2507.2

C 955—09

Standard Specification for Load-bearing Transverse and Axial Steel Studs, Runners Tracks, and Bracing or Bridging, for Screw Application of Gypsum Panel Products and Metal Plaster Bases

Table 2506.2, Table 2507.2

C 956—04

Specification for Installation of Cast-in-place Reinforced Gypsum Concrete

1911.1

C 957—06

Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane with Integral Wearing Surface

1507.15.2

C 1002—07

Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs

Table 2506.2, Table 2507.2

C 1007—08a

Specification for Installation of Load Bearing (Transverse and Axial) Steel Studs and Related Accessories

Table 2508.1, Table 2511.1.1

C 1019—09

Test Method of Sampling and Testing Grout

2105.2.2.1.1, 2105.2.2.1.2, 2105.2.2.1.3

C 1029—08

Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation

1507.14.2

C 1032—06

Specification for Woven Wire Plaster Base

Table 2507.2

C 1047—09

Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base

Table 2506.2, Table 2507.2

C 1063—08

Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster

2109.3.4.8, 2510.3, Table 2511.1.1, 2512.1.1

C 1088—09

Specification for Thin Veneer Brick Units Made from Clay or Shale

Table 721.1(2), 2103.2

C 1167—03

Specification for Clay Roof Tiles

1507.3.4

C 1177/C 1177M—08

Specification for Glass Mat Gypsum Substrate for Use as Sheathing

Table 2506.2

C 1178/C 1178M—06

Specification for Coated Mat Water-resistant Gypsum Backing Panel

Table 2506.2, 2509.2

C 1186—08

Specification for Flat Fiber Cement Sheets

1404.10, 1405.16.1, 1405.16.2

C 1261—07

Specification for Firebox Brick for Residential Fireplaces

2111.5, 2111.8

C 1278/C 1278M—07a

Specification for Fiber-reinforced Gypsum Panels

Table 2506.2

C 1280—09

Specification for Application of Gypsum Sheathing

Table 2508.1, 2508.2

C 1283—07a

Practice for Installing Clay Flue Lining

2113.9.1, 2113.12

C 1288—99 (2004) e1

Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets

2509.2

C 1289—08

Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

Table 1508.2

C 1325—08b

Standard Specification for Nonasbestos Fiber-mat Reinforced Cementitious Backer Units

2509.2

C 1328—05

Specification for Plastic (Stucco Cement)

Table 2507.2

C 1364—07

Standard Specification for Architectural Cast Stone

2103.5

C 1386—07

Specification for Precast Autoclaved Aerated Concrete (AAC) Wall Construction Units

202, 2103.3, 2105.2.2.1.3

C 1396/C 1396M—06a

Specification for Gypsum Board

Figure 722.5.1(2), Figure 722.5.1(3), Table 2506.2

C 1405—08

Standard Specification for Glazed Brick (Single Fired, Solid Brick Units)

2103.2

C 1492—03

Standard Specification for Concrete Roof Tile

1507.3.5

C 1629/C 1629M—06

Standard Classification for Abuse-resistant Nondecorated Interior Gypsum Panel Products and Fiber-reinforced Cement Panels

403.2.3.1, 403.2.3.2, 403.2.3.4

C 1658/C 1658M—06

Standard Specification for Glass Mat Gypsum Panels

Table 2506.2

D 25—99 (2005)

Specification for Round Timber Piles

1810.3.2.4, 2303.1.11

D 41—05

Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing Table

1507.10.2

D 43—00 (2006)

Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing

Table 1507.10.2

D 56—05

Test Method for Flash Point By Tag Closed Tester

202

D 86—09

Test Method for Distillation of Petroleum Products at Atmospheric Pressure

202

D 93—08

Test Method for Flash Point By Pensky-Martens Closed Cup Tester

202

D 225—07

Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules

1507.2.5

D 226—06

Specification for Asphalt-saturated Organic Felt Used in Roofing and Waterproofing

1404.2, 1507.2.3, 1507.2.8.1, 1507.3.3, 1507.4.5 1507.5.3, 1507.6.3, 1507.6.3.1, 1507.7.3, Table 1507.8, 1507.8.3, 1507.9.3, 1507.9.5, Table 1507.10.2

D 227—03

Specification for Coal-tar-saturated Organic Felt Used in Roofing and Waterproofing

Table 1507.10.2

D 312—00 (2006)

Specification for Asphalt Used in Roofing

Table 1507.10.2

D 422—63 (2007)

Test Method for Particle-size Analysis of Soils

1803.5.3

D 448—08

Standard Classification for Sizes of Aggregate for Road and Bridge Construction

1507.12.3, 1507.13.3

D 450—07

Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing

Table 1507.10.2

D 635—06

Test Method for Rate of Burning and/or Extent and Time of Burning of Self-supporting Plastics in a Horizontal Position

2606.4, H107.1.1

D 1143/D 1143M—07e1

Test Method for Piles Under Static Axial Compressive Load

1810.3.3.1.2

D 1227—95 (2007)

Specification for Emulsified Asphalt Used as a Protective Coating for Roofing

Table 1507.10.2, 1507.15.2

D 1557—07

Test Method for Laboratory Compaction Characteristics of Soil Using Modified Effort [56,000 ft-lb/ft3 (2,700 KN m/m3)]

1705.6, 1804.5, J107.5

D 1761—06

Test Method for Mechanical Fasteners in Wood

1711.1.1, 1711.1.2, 1711.1.3

D 1863—05

Specification for Mineral Aggregate Used on Built-up Roofs

Table 1507.10.2

D 1929—96 (2001) e01

Test Method for Determining Ignition Properties of Plastics

402.6.4.4, 406.7.2, 1407.11.2.1, 1407.11.3.3, 1407.11.4.2, 2606.4

D 1970—09

Specification for Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection

1507.2.4, 1502.2.8.1, 1507.2.9.2, 1507.3.3.31507.3.9, 1507.4.5, 1507.5.3.1, 1507.5.7, 1507.6.3.1, 1507.7.3.1, 1507.8.3.1, 1507.8.8, 1507.9.3.1, 1507.9.9

D 2178—04

Specification for Asphalt Glass Felt Used in Roofing and Waterproofing

Table 1507.10.2

D 2487—06e1

Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System)

Table 1610.1, 1803.5.1

D 2626—04

Specification for Asphalt Saturated and Coated Organic Felt Base Sheet Used in Roofing

1507.3.3, Table 1507.10.2

D 2822—05

Specification for Asphalt Roof Cement, Asbestos Containing

Table 1507.10.2

D 2823—05

Specification for Asphalt Roof Coatings, Asbestos Containing

Table 1507.10.2

D 2824—06

Standard Specification for Aluminum-Pigmented Asphalt Roof Coating, Nonfibered, Asbestos Fibered and Fibered without Asbestos

Table 1507.10.2

D 2843—99 (2004) e01

Test for Density of Smoke from the Burning or Decomposition of Plastics

2606.4

D 2859—06

Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials

804.4.1

D 2898—08e01

Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing

1505.1, 2303.2.4, 2303.2.6

D 3019—08

Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered

Table 1507.10.2

D 3161—09

Test Method for a Wind Resistance of Asphalt Shingles (Fan Induced Method)

1507.2.7.1, Table 1507.2.7.1(2)

D 3200—74 (2005)

Standard Specification and Test Method for Establishing Recommended Design Stresses for Round Timber Construction Poles

2303.1.11

D 3201—08a

Test Method for Hygroscopic Properties of Fire-retardant-treated Wood and Wood-based Products

2303.2.7

D 3278—96 (2004)

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

D 3462—09

Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules

1507.2.5

D 3468—99 (2006) e01

Specification for Liquid-applied Neoprene and Chlorosulfonated Polyethylene Used in Roofing and Waterproofing

1507.15.2

D 3679—09

Specification for Rigid Poly [Vinyl Chloride (PVC) Siding]

1404.9, 1405.14

D 3689—07

Test Methods for Deep Foundations Under Static Axial Tensile Load

1810.3.3.1.5

D 3737—08

Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)

2303.1.3

D 3746—85 (2008)

Test Method for Impact Resistance of Bituminous Roofing Systems

1504.7

D 3747—79 (2007)

Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation

Table 1507.10.2

D 3909—97b (2004)

Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules

1507.2.9.2, 1507.6.5, Table 1507.10.2

D 3957—06

Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings

2303.1.10

D 4022—07

Specification for Coal Tar Roof Cement, Asbestos Containing

Table 1507.10.2

D 4272—08a

Test Method for Total Energy Impact of Plastic Films by Dart Drop

1504.7

D 4318—05

Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils

1803.5.3

D 4434/D 4434M—09

Specification for Poly (Vinyl Chloride) Sheet Roofing

1507.13.2

D 4479—07

Specification for Asphalt Roof Coatings-Asbestos-free

Table 1507.10.2

D 4586—07

Specification for Asphalt Roof Cement-Asbestos-free

Table 1507.10.2

D 4601—04

Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing

Table 1507.10.2

D 4637—08

Specification for EPDM Sheet Used in Single-ply Roof Membrane

1507.12.2

D 4829—08a

Test Method for Expansion Index of Soils

1803.5.3

D 4869—05e01

Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing

1507.2.3, 1507.2.8.1, 1507.4.5, 1507.5.3, 1507.5.3.1, 1507.6.3, 1507.7.3, 1507.7.3.1, 1507.8.3, 1507.8.3.1, 1507.9.3, 1507.9.3.1

D 4897—01

Specification for Asphalt-coated Glass Fiber Venting Base Sheet Used in Roofing

Table 1507.10.2

D 4945—08

Test Method for High-strain Dynamic Testing of Piles

1810.3.3.1.2

D 4990—97a (2005) e01

Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing

Table 1507.10.2

D 5019—07a

Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane

1507.12.2

D 5055—09

Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists

2303.1.2

D 5456—09

Specification for Evaluation of Structural Composite Lumber Products

2303.1.9

D 5516—03

Test Method of Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures

2303.2.5.1

D 5643—06

Specification for Coal Tar Roof Cement, Asbestos-free

Table 1507.10.2

D 5664—08

Test Methods for Evaluating the Effects of Fire-retardant Treatment and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber

2303.2.5.2

D 5665—99a (2006)

Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing

Table 1507.10.2

D 5726—98 (2005)

Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing

Table 1507.10.2

D 6083—05e01

Specification for Liquid Applied Acrylic Coating Used in Roofing

Table 1507.10.2, Table 1507.14.3, 1507.15.2

D 6162—00A (2008)

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2

D 6163—00 (2008)

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements

1507.11.2

D 6164—05e1

Specification for Styrene-butadiene-styrene (SBS) Modified Bituminous Sheet Metal Materials Using Polyester Reinforcements

1507.11.2

D 6222—08

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements

1507.11.2

D 6223—02

Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements

1507.11.2

D 6298—05e1

Specification for Fiberglass Reinforced Styrene-butadiene-styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface

1507.11.2

D 6305—08

Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing

2303.2.5.1

D 6380—03 (2009)

Standard Specification for Asphalt Roll Roofing (Organic) Felt

1507.2.9.2, 1507.3.3, 1507.6.5

D 6509/D 6509M—09

Standard Specification for Atactic Polypropylene (APP) Modified Bituminous base Sheet Materials Using Glass Fiber Reinforcements

1507.11.2

D 6694—08

Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing

Table 1507.14.3, 1507.15.2

D 6754—02

Standard Specification for Ketone Ethylene Ester Based Sheet Roofing

1507.13.2

D 6757—07

Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products

1507.2.3

D 6841—08

Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber

2303.2.5.2

D 6878—08e1

Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing

1507.13.2

D 6947—07

Standard Specification for Liquuid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System

Table 1507.14.3, 1507.15.2

D 7158—08d

Standard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method)

1507.2.7.1, Table 1507.2.7.1(1)

D 7254—07

Standard Specification for polypropylene (PP) siding

1404.12

E 84—09

Test Methods for Surface Burning Characteristics of Building Materials

202, 402.6.4.4, 406.7.2, 703.5.2, 720.1, 720.4, 803.1.1, 803.1.4, 803.9, 803.13, 806.5, 1404.12.1, 1407.9, 1407.10.1, 1409.9, 1409.10.1, 1509.6.2, 1509.6.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4, 2603.7, 2604.2.4, 2606.4, 2613.3, 3105.4

E 90—04

Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements

1207.2, 1207.2.1

E 96/E 96M—05

Test Method for Water Vapor Transmission of Materials

202

E 108—07a

Test Methods for Fire Tests of Roof Coverings

1505.1, 2603.6, 2610.2, 2610.3

E 136—09

Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C

703.5.1

E 329—02

Standard Specification for Agencies Engaged in the Testing and/or Inspection of Materials Used in Construction

1703.1, 1703.1.3

E 330—02

Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference

1409.10.2, 1710.5.2

E 331—00 (2009)

Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference

1403.2

E 492—09

Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-ceiling Assemblies Using the Tapping Machine

1207.3

E 605—93 (2006)

Test Method for Thickness and Density of Sprayed Fire-resistive Material (SFRM) Applied to Structural Members

1705.13.4.1, 1705.13.4.2

E 681—04

Test Methods for Concentration Limits of Flammability of Chemical Vapors and Gases

202

E 736—00 (2006)

Test Method for Cohesion/Adhesion of Sprayed Fire-resistive Materials Applied to Structural Members

704.13.2, 1705.13.6

E 814—08b

Test Method of Fire Tests of Through-penetration Firestops

202, 714.3.1.2, 714.3.2, 7143.4.1.1.2

E 970—08a

Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

720.3.1

E 1300—07e01

Practice for Determining Load Resistance of Glass in Buildings

2404.1, 2404.2, 2404.3.1, 2404.3.2, 2404.3.3, 2404.3.4, 2404.3.5

E 1354—09

Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

424.2

E 1592—05

Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

1504.3.2

E 1602—03

Guide for Construction of Solid Fuel-burning Masonry Heaters

2112.2

E 1886—05

Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters Impacted by Missiles and Exposed to Cyclic Pressure Differentials

1609.1.2

E 1966—07

Test Method for Fire-resistant Joint Systems

202, 715.3

E 1996—09

Specification for Performance of Exterior Windows, Glazed Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

1609.1.2, 1609.1.2.2

E 2072—04

Standard Specification for Photoluminescent (Phosphorescent) Safety Markings

1024.4

E 2174—09

Standard Practice for On-Site Inspection of Installed Fire Stops

1705.16.1

E 2273—03

Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies

1408.4.1

E 2307—04e01

Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-scale, Multistory Test Apparatus

715.4

E 2393—09

Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barrier

1705.16.2

E 2404—08

Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics

803.1.4

E 2568—09e1

Standard Specification for PB Exterior Insulation and Finish Systems (EIFS)

1408.2

E 2570—07

Standard Test Method for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) for EIFS with Drainage

1408.4.1.1, 1705.15.1

E 2573—07a

Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics

803.13

E 2599—09

Standard Practice for Specimen Preparation and Mounting of Reflective Insulation Materials and Radiant Barrier Materials for Building Applications to Assess Surface Burning Characteristics

2613.3

E 2634—08

Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems

1903.3

F 547—06

Terminology of Nails for Use with Wood and Wood-based Materials

Table 2506.2

F 1346—91 (2003)

Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs

3109.4, 3109.4.1.8

F 1667—05

Specification for Driven Fasteners: Nails, Spikes and Staples

Table 721.1(2), Table 721.1(3), 1507.2.6, 2303.6, Table 2506.2

F 2006—00 (2005) 10

Standard/Safety Specification for Window Fall Prevention Devices with Emergency Escape (Egress) and Rescue (Ingress) Windows

1013.8

F 2090—08

Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms

1013.8, 1013.8.1

F 2200—05

Standard Specification for Automated Vehicular Gate Construction

3110.3

G 152—06

Practice for Operating Open Flame Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials

1504.6

G 154—06

Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials

1504.6

G 155—05a

Practice for Operating Xenon Arc Light Apparatus for Exposure of Nonmetallic Materials

1504.6

AWCI

Association of the Wall and Ceiling Industry
513 West Broad Street, Suite 210
Falls Church VA 22046
Standard
reference
number
TitleReferenced
in code
section number

12-B—98

Technical Manual 12-B Standard Practice for the Testing and Inspection of Field Applied Thin Film Intumescent Fire-resistive Materials; an Annotated Guide, First Edition

1705.14

AWPA

American Wood Protection Association
P.O. Box 361784
Birmingham AL 35236-1784
Standard
reference
number
TitleReferenced
in code
section number

C1—03

All Timber Products-Preservative Treatment by Pressure Processes

1505.6

M4—08

Standard for the Care of Preservative-treated Wood Products

1810.3.2.4.1, 2303.1.8

U1—11

USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6, Commodity Specification H

1403.6, Table 1507.9.6, 1807.1.4, 1807.3.1, 1809.12, 1810.3.2.4.1, 2303.1.8, 2303.1.8.1, 2304.11.2, 2304.11.4, 2304.11.6, 2304.11.7

AWS

American Welding Society
550 N.W. LeJeune Road
Miami FL 33126
Standard
reference
number
TitleReferenced
in code
section number

D1.3—98

Structural Welding Code-Sheet Steel

Table 1705.2.2, 1705.2.2.1.1

D1.4—98

Structural Welding Code-Reinforcing Steel

Table 1705.2.2, 1705.2.2.1.2, Table 1705.3, 2107.4

BHMA

Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York NY 10017-6603
Standard
reference
number
TitleReferenced
in code
section number

A 156.10—2011

Power Operated Pedestrian Doors

1008.1.4.2

A 156.19—2007

Standard for Power Assist and Low Energy Operated Doors

1008.1.4.2

CGSB

Canadian General Standards Board
Place du Portage 111, 6B1 11 Laurier Street
Gatineau Quebec, Canada KIA 1G6
Standard
reference
number
TitleReferenced
in code
section number

37-GP-52M (1984)

Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric

1504.7, 1507.12.2

37-GP-56M (1980)

Membrane, Modified, Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment

1507.11.2

CAN/CGSB 37.54—95

Polyvinyl Chloride Roofing and Waterproofing Membrane

1507.13.2

CPA

Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg VA 20176
Standard
reference
number
TitleReferenced
in code
section number

ANSI A135.4—2004

Basic Hardboard

1404.3.1, 2303.1.6

ANSI A135.5—2004

Prefinished Hardboard Paneling

2303.1.6, 2304.6.2

ANSI A135.6—2006

Hardboard Siding

1404.3.2, 2303.1.6

CPSC

Consumer Product Safety Commission
4330 East West Highway
Bethesda MD 20814-4408
Standard
reference
number
TitleReferenced
in code
section number

16 CFR Part 1201 (2002)

Safety Standard for Architectural Glazing Material

2406.2, Table 2406.2(1), 2406.3.1, 2407.1, 2407.1.4.1, 2408.2.1,2408.3, 2409.1, 2409.2, 2409.3.1

16 CFR Part 1209 (2002)

Interim Safety Standard for Cellulose Insulation

720.6

16 CFR Part 1404 (2002)

Cellulose Insulation

720.6

16 CFR Part 1500 (2009)

Hazardous Substances and Articles; Administration and Enforcement Regulations

202

16 CFR Part 1500.44 (2009)

Method for Determining Extremely Flammable and Flammable Solids

202

16 CFR Part 1507 (2002)

Fireworks Devices

202

16 CFR Part 1630 (2007)

Standard for the Surface Flammability of Carpets and Rugs

804.4.1

CSA

Canadian Standards Association
5060 Spectrum Way
Mississauga Ontario Canada L4W 5N6
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A440—11

Specifications for Windows, Doors and Unit Skylights

1710.5.1, 2405.5

CSSB

Cedar Shake and Shingle Bureau
P. O. Box 1178
Sumas WA 98295-1178
Standard
reference
number
TitleReferenced
in code
section number

CSSB—97

Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau

Table 1507.8.5, Table 1507.9.6

DASMA

Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number

ANSI/DASMA 107—1997 (R2004)

Room Fire Test Standard for Garage Doors Using Foam Plastic Insulation

2603.4.1.9

108—05

Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Uniform Static Air Pressure Difference

1710.5.2

115—05

Standard Method for Testing Sectional Garage Doors and Rolling Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure

1609.1.2.3

DOC

U.S. Department of Commerce
National Institute of Standards and Technology
1401 Constitution Avenue NW
Washington DC 20230
Standard
reference
number
TitleReferenced
in code
section number

PS-2—10

Performance Standard for Wood-based Structural-use Panels

2303.1.4, 2304.6.2, Table 2304.7(5), Table 2306.2(1), Table 2306.2(2)

PS 20—05

American Softwood Lumber Standard

202, 1810.3.2.4, 2303.1.1

DOJ

U.S. Department of Justice
950 Pennsylvania Avenue, NW
Civil Rights Division, Disability Rights Section-NYA
Washington DC 20530
Standard
reference
number
TitleReferenced
in code
section number

DOJ 36 CFR Part 1192

American with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (ADAAG) Department of Justice, 1991

E109.2.4

DOL

U.S. Department of Labor
c/o Superintendent of Documents U.S. Government Printing Office
Washington DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number

29 CFR Part 1910.1000 (2009)

Air Contaminants

202

DOTn

U.S. Department of Transportation
c/o Superintendent of Documents
1200 New Jersey Avenue, SE
Washington DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number

49 CFR Parts 100—185 2005

Hazardous Materials Regulations

202

49 CFR Parts 173.137 (2009)

Shippers—General Requirements for Shipments and Packaging—Class 8—Assignment of Packing Group

202

49 CFR—1998

Specification of Transportation of Explosive and Other Dangerous Articles, UN 0335, UN 0336 Shipping Containers

202

EN

European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
TitleReferenced
in code
section number

EN 1081—98

Resilient Floor Coverings—Determination of the Electrical Resistance

406.7.1

FEMA

Federal Emergency Management Agency
Federal Center Plaza
500 C Street S.W.
Washington DC 20472
Standard
reference
number
TitleReferenced
in code
section number

FIA-TB-11—01

Crawlspace Construction for Buildings Located in Special Flood Hazard Areas

1805.1.2.1

P646—08

Guidelines for Design for Structures for Vertical Evacuation from Tsunamis

M101.4

FM

Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston RI 02919
Standard
reference
number
TitleReferenced
in code
section number

4450 (1989)

Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992

1508.1, 2603.3, 2603.4.1.5

4470 (1992)

Approval Standard for Class 1 Roof Covers

1504.7

4474 (04)

Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures

1504.3.1

4880 (2005)

American National Standard for Evaluating Insulated Wall or Wall and Roof/ Ceiling Assemblies, Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,Interior and Exterior Finish Systems

2603.4, 2603.10

GA

Gypsum Association
810 First Street N.E. #510
Washington DC 20002-4268
Standard
reference
number
TitleReferenced
in code
section number

GA 216—07

Application and Finishing of Gypsum Panel Products

Table 2508.1, 2509.2

GA 600—09

Fire-Resistance Design Manual, 18th Edition

Table 721.1(1), Table 721.1(2), Table 721.1(3)

HPVA

Hardwood Plywood Veneer Association
1825 Michael Faraday Drive
Reston VA 20190
Standard
reference
number
TitleReferenced
in code
section number

HP-1—2009

Standard for Hardwood and Decorative Plywood

2303.3, 2304.6.2

HUD

U.S. Department of Housing and Urban Development
451 7th Street, SW
Washington DC 20410
Standard
reference
number
TitleReferenced
in code
section number

HUD 24 CFR Part 3280 (2008)

Manufactured Home Construction and Safety Standards

G201

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001
Standard
reference
number
TitleReferenced
in code
section number

ICC 400—12

Standard on Design and Construction of Log Structures

2301.2

ICC 500—08

ICC/NSSA Standard on the Design and Construction of Storm Shelters

202, 423.1

ICC 600—08

Standard for Residential Construction in High-wind Regions

1609.1.1, 1609.1.1.1, 2308.2.1

IPMC—12

International Property Maintenance Code®

102.6, 103.3, 3401.3, 3412.3.2

IPSDC—12

International Private Sewage Disposal Code®

2901.1, 3401.3

IWUIC—12

International Wildland-Urban Interface Code®

Table 1505.1

SBCCI SSTD 11—97

Test Standard for Determining Wind Resistance of Concrete or Clay Roof Tiles

1711.2.1, 1711.2.2

ISO

International Organization for Standardization
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case Postale 56
CH-1211 Geneva 20 Switzerland
Standard
reference
number
TitleReferenced
in code
section number

ISO 8115—86

Cotton Bales—Dimensions and Density

Table 307.1(1), Table 415.10.1.1.1

NAAMM

National Association of Architectural Metal Manufacturers
800 Roosevelt Road, Bldg. C, Suite 312
Glen Ellyn IL 60137
Standard
reference
number
TitleReferenced
in code
section number

FP 1001—07

Guide Specifications for Design of Metal Flag Poles

1609.1.1

NCMA

National Concrete Masonry Association
13750 Sunrise Valley
Herndon VA 22071-4662
Standard
reference
number
TitleReferenced
in code
section number

TEK 5—84 (1996)

Details for Concrete Masonry Fire Walls

Table 721.1(2)

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
Standard
reference
number
TitleReferenced
in code
section number

1010

Portable Fire Extinguishers

906.2, 906.3.2, 906.3.4, Table 906.3(1), Table 906.3(2)

1110

Low Expansion Foam

904.7

12A—09 Halon 1301

Halon 1301 Fire Extinguishing Systems

904.9

1310

Installation of Sprinkler Systems

708.2, 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2, 904.11, 905.3.4, 907.6.3, 1009.3

13D—10

Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes

903.3.1.3, 903.3.5.1.1

13R—10

Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height

903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4

1410

Installation of Standpipe and Hose System

905.2, 905.3.4, 905.4.2, 905.6.2, 905.8

1611

Installation of Foam-water Sprinkler and Foam-water Spray Systems

904.7, 904.11

17—09

Dry Chemical Extinguishing Systems

904.6, 904.11

17A—09

Wet Chemical Extinguishing Systems

904.5, 904.11

2010

Installation of Stationary Pumps for Fire Protection

913.1, 913.2.1, 913.5

3111

Installation of Oil-burning Equipment

2113.15

3211

Dry Cleaning Plants

415.8.4

40—11

Storage and Handling of Cellulose Nitrate Film

409.1

58—11

Liquefied Petroleum Gas Code

415.8.3

61—08

Prevention of Fires and Dust Explosions in Agricultural and Food Product Facilities

415.8.1

70—11

National Electrical Code

415.10.1.8, 904.3.1, 907.6.1, 909.12.1, 909.16.3, 1205.4.1, 2701.1, 3401.3, H106.1, H106.2, K101, K111.1

82—09

Standard for Incinerators and Waste and Linen Handling Systems and Equipment, 2009 Edition

713.13

85—11

Boiler and Combustion System Hazards Code (Note: NFPA 8503 has been incorporated into NFPA 85)

415.8.1

92B—09

Smoke Management Systems in Malls, Atria and Large Spaces

909.8

99—05

Standard for Health Care Facilities

407.10

10112

Life Safety Code

1028.6.2

10510

Standard for the Installation of Smoke Door Assemblies

405.4.2, 710.5.2.2, 716.5.3.1, 909.20.4.1

11010

Emergency and Standby Power Systems

2702.1

11110

Stored Electrical Energy Emergency and Standby Power Systems

2702.1

120—10

Coal Preparation Plants

415.8.1

170—09

Standard for Fire Safety and Emergency Symbols

1024.2.6.1

211—10

Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

2112.5

221—09

Standard for High Challenge Fire Walls, Fire Walls, and Fire Barrier Walls, 2009 Edition

706.2

252—03

Standard Methods of Fire Tests of Door Assemblies

715.4.2, 715.4.3, 715.4.7.3.1, Table 716.3, 716.4, 716.5.1, 716.5.3, 716.5.8, 716.5.8.1.1, 716.5.8.3.1

253—11

Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source

406.8.3, 424.2, 804.2, 804.3

257—07

Standard for Fire Test for Window and Glass Block Assemblies

Table 716.3, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.7.3

259—08

Test Method for Potential Heat of Building Materials

2603.4.1.10, 2603.5.3

265—11

Method of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings on Full Height Panels and Walls

803.1.3, 803.1.3.1

268—12

Standard Test Method for Determining Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source

1406.2.1.1, 1406.2.1.1.1, 1406.2.1.1.2, 2603.5.7, D105.1

275—09

Standard Method Of Fire Tests for the Evaluation of Thermal Barriers Used Over Foam Plastic Insulation

1407.10.2, 2603.4

285—06

Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Nonload-bearing Wall Assemblies Containing Combustible Components

718.2.6, 1403.5, 1407.10.4, 1409.10.4, 1509.6.2, 2603.5.5

286—11

Standard Method of Fire Test for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

402.6.4.4, 803.1.2, 803.1.2.1, 803.9, 2603.4, 2603.7, 2603.10, 2604.2.4, 2613.4

288—12

Standard Method of Fire Tests of Floor Fire Door Assemblies Installed Horizontally in Fire-resistance-rated Floor Systems

711.8

289—09

Standard Method of Fire Test for Individual Fuel Packages

402.6.2, 407.6.4.6, 424.2

41811

Standard for Heliports

412.7.4

484—12

Combustible Metals

415.8.1

654—06

Prevention of Fire & Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids

415.8.1

655—12

Prevention of Sulfur Fires and Explosions

415.8.1

664—12

Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities

415.8.1

70110

Standard Methods of Fire Tests for Flame-propagation of Textiles and Films

410.3.6, 424.2, 801.4, 806.1, 806.1.2, 806.2, 3102.3, 3102.3.1, 3102.6.1.1, 3105.4, D102.2.8, H106.1.1

70412

Standard System for the Identification of the Hazards of Materials for Emergency Response

202, 414.7.2

720—09

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

908.7

1124—06

Manufacture, Transportation and Storage of Fireworks and Pyrotechnic Articles

415.5.1.1, 415.3.1

200111

Clean Agent Fire Extinguishing Systems

904.10

PCI

Precast Prestressed Concrete Institute
200 West Adams Street, Suite 2100
Chicago IL 60606-5230
Standard
reference
number
TitleReferenced
in code
section number

MNL 124—89

Design for Fire Resistance of Precast Prestressed Concrete

722.2.3.1

MNL 128—01

Recommended Practice for Glass Fiber Reinforced Concrete Panels

1903.2

PTI

Post-Tensioning Institute
8601 North Black Canyon Highway, Suite 103
Phoenix AZ 85021
Standard
reference
number
TitleReferenced
in code
section number

PTI—2007

Standard Requirements for Analysis of Shallow Concrete Foundations on Expansive Soils, Third Edition

1808.6.2

PTI—2007

Standard Requirements for Design of Shallow Post-tensioned Concrete Foundation on Expansive Soils, Second Edition

1808.6.2

RMI

Rack Manufacturers Institute
8720 Red Oak Boulevard, Suite 201
Charlotte NC 28217
Standard
reference
number
TitleReferenced
in code
section number

ANSI/MH16.1—08

Specification for Design, Testing and Utilization of Industrial Steel Storage Racks

2209.1

SDI

Steel Deck Institute
P. O. Box 25
Fox River Grove IL 60021
Standard
reference
number
TitleReferenced
in code
section number

ANSI/NC1.0—10

Standard for Noncomposite Steel Floor Deck

2210.1.1.1

ANSI/RD1.0—10

Standard for Steel Roof Deck

2210.1.1.2

SJI

Steel Joist Institute
1173B London Links Drive
Forest VA 24551
Standard
reference
number
TitleReferenced
in code
section number

CJ—10

Standard Specification for Composite Steel Joists, CJ-series

1604.3.3, 2203.2, 2207.1

JG—10

Standard Specification for Joist Girders

1604.3.3, 2203.2, 2207.1

K—10

Standard Specification for Open Web Steel Joists, K-series

1604.3.3, 2203.2, 2207.1

LH/DLH—10

Standard Specification for Longspan Steel Joists, LH-series and Deep Longspan Steel Joists, DLH-series

1604.3.3, 2203.2, 2207.1

SPRI

Single-Ply Roofing Institute
411 Waverly Oaks Road, Suite 331B
Waltham MA 02452
Standard
reference
number
TitleReferenced
in code
section number

ANSI/SPRI/FM4435-ES-1—03

Wind Design Standard for Edge Systems Used with Low Slope Roofing Systems

1504.5

RP-4—08

Wind Design Guide for Ballasted Single-ply Roofing Systems

1504.4

TFI

The Fertilizer Institute
820 First Street, NE, Suite 430
Washington DC 20002
Standard
reference
number
TitleReferenced
in code
section number

RMIP—09

Aboveground Storage Tanks Containing Liquid Fertilizer, Recommended Mechanical Integrity Practices

426.2, 426.4, 426.5

TIA

Telecommunications Industry Association
2500 Wilson Boulevard
Arlington VA 22201-3834
Standard
reference
number
TitleReferenced
in code
section number

222-G—05

Structural Standards for Antenna Supporting Structures and Antennas, including—Addendum 1, 222-G-1, Dated 2007 and Addendum 2, 222-G-2 Dated 2009

1609.1.1, 3108.1, 3108.2

TMS

The Masonry Society
3970 Broadway, Unit 201-D
Boulder CO 80304-1135
Standard
reference
number
TitleReferenced
in code
section number

0216—97

Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies

Table 721.1(2), 722.1

0302—07

Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls

1207.2.1

40310

Direct Design Handbook for Masonry Structures

2101.2.7

TPI

Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria VA 22314
Standard
reference
number
TitleReferenced
in code
section number

TPI 1—2007

National Design Standards for Metal-plate-connected Wood Truss Construction

2303.4.6, 2306.1

UL

Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook IL 60062-2096
Standard
reference
number
TitleReferenced
in code
section number

9—2009

Fire Tests of Window Assemblies—with Revisions through April 2005

715.5.2, 716.4, 716.5.3.2, 716.6, 716.6.1, 716.6.2, 716.6.8.1

10A—2009

Tin Clad Fire Doors

716.5

10B—2008

Fire Tests of Door Assemblies—with Revisions through April 2009

716.5.2

10C—2009

Positive Pressure Fire Tests of Door Assemblies

716.5.1, 716.5.3, 1008.1.10.1

14B—2008

Sliding Hardware for Standard Horizontally-mounted Tin Clad Fire Doors

716.5

14C—06

Swinging Hardware for Standard Tin Clad Fire Doors Mounted Singly and in Pairs—with revisions through December 2008

716.5

55A—04

Materials for Built-Up Roof Coverings

1507.10.2

103—01

Factory-built Chimneys, for Residential Type and Building Heating Appliances—with Revisions through March 2010

718.2.5.1

127—08

Factory-built Fireplaces—with Revisions through January 2010

718.2.5.1, 2111.11

199E—04

Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers

904.11.4.1

217—06

Single and Multiple Station Smoke Alarms—with Revisions through April 2010

907.2.11

263—03

Standard for Fire Tests of Building Construction and Materials, with revisions through October 2007

703.2, 703.2.1, 703.2.3, 703.3, 703.4, 703.6, 704.12, 705.7, 705.8.5, 707.7, 711.3.2, 714.3.1, 714.4.1.1, 715.1, 716.2, Table 716.3, 716.5.6, 716.5.8.1.1, 716.7.1, 717.5.2, 717.5.3, 717.6.2.1, Table 721.1(1), 1407.10.2, 2103.2, 2603.4, 2603.5.1

268—09

Smoke Detectors for Fire Protective Signaling Systems—with Revisions through January 1999

407.8, 907.2.6.2

294—1999

Access Control System Units with revisions through 2009

1008.1.9.8

300—05

Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment

904.11

305—97

Panic Hardware—with revisions through January 2007

1008.1.10.1

325—02

Door, Drapery, Gate, Louver and Window Operations and Systems—with Revisions through February 2010

405.3.5, 3110.4

555—2006

Fire Damperswith revisions through May 2010

717.3

555C—2006

Ceiling Damperswith revisions through May 2010

717.3

555S—99

Smoke Dampers—with Revisions through May 2010

717.3, 717.3.1

580—2006

Test for Uplift Resistance of Roof Assemblies—with Revisions through July 2009

1504.3.1, 1504.3.2

641—95

Type L Low-temperature Venting Systems—with Revisions through July 2009

2113.11.1.4

710B—04

Recirculating Systems—with Revisions through December 2009

904.11

723—2008

Standard for Test for Surface Burning Characteristics of Building Materials

202, 402.6.4.4, 406.7.2, 703.5.2, 720.1, 720.4, 803.1.1, 803.1.4, 803.9, 803.13, 806.5, 1404.12.1, 1407.9, 1407.10.1, 1409.9, 1409.10.1, 1509.6.2, 1509.6.3, 2303.2, 2603.3, 2603.4.1.13, 2606.3.5.4, 2603.7, 2604.2.4, 2606.4, 2613.3, 3105.4

790—04

Standard Test Methods for Fire Tests of Roof Coverings—with Revisions through October 2008

1505.1, 2603.6, 2610.2, 2610.3

793—08

Standards for Automatically Operated Roof Vents for Smoke and Heat

406.8.5.1.1, 910.3.1

864—03

Standards for Control Units and Accessories for Fire Alarm Systems—with Revisions through February 2010

909.12

924—06

Standard for Safety Emergency Lighting and Power Equipment—with Revisions through January 2009

1011.5

1040—96

Fire Test of Insulated Wall Construction— with Revisions through September 2007

1407.10.3, 1409.10.3, 2603.4, 2603.10

1256—02

Fire Test of Roof Deck Construction— with Revisions through January 2007

1508.1, 2603.3, 2603.4.1.5

1479—03

Fire Tests of Through-penetration Firestops—with Revisions through March 2010

202, 714.3.1.2, 714.3.2, 714.4.1.1.2, 714.5

1482—2010

Solid-Fuel-type Room Heater

2112.2, 2112.5

1703—02

Flat-Plate Photovoltaic Modules and Panels— with Revisions through April 2008

1507.17.1, 1509.7.4

1715—97

Fire Test of Interior Finish Material— with Revisions through April 2008

1407.10.3, 1409.10.2, 1409.10.3, 2603.4, 2603.10, 2613.4

1777—2007

Chimney Liners— with Revisions through July 2009

2113.11.1, 2113.19

1784—01

Air Leakage Tests of Door Assemblies— with Revisions through July 2009

710.5.2.2, 713.14.1, 716.5.3.1, 716.5.7.1, 716.5.7.3, 3007.7.3, 3008.7.3

1897—04

Uplift Tests for Roof Covering Systems— with Revisions through May 2008

1504.3.1

1975—06

Fire Test of Foamed Plastics Used for Decorative Purposes

402.6.2, 402.6.4.5, 424.2

1994—04

Luminous Egress Path Marking Systems— with Revisions through April 2010

411.7, 1024.2.1, 1024.2.3, 1024.2.4, 1024.4

2017—2008

Standards for General-purpose Signaling Devices and Systems— with Revisions through October 2009

406.8.5.1.1, 3109.4.1.8

2034—2008

Standard for Single- and Multiple Station Carbon Monoxide Alarm—with Revisions through February 2009

908.7

2075—04

Standard for Gas and Vapor Detectors and Sensors—with Revisions through September 2007

908.7.3

2079—04

Tests for Fire Resistance of Building Joint Systems— with Revisions through June 2008

202, 715.3, 715.6

2200—98

Stationary Engine Generator Assemblies— with Revisions through December 2009

2702.1.1

ULC

Underwriters Laboratories of Canada
7 Underwriters Road
Toronto Ontario, Canada M1R3B4
Standard
reference
number
TitleReferenced
in code
section number

CAN/ULC S 102.2—1988

Standard Method of Test for Surface Burning Characteristics of Flooring, Floor Coverings and Miscellaneous Materials and Assemblies—with 2000 Revisions

720.4

USC

United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325
Standard
reference
number
TitleReferenced
in code
section number

18 USC Part 1, Ch.40

Importation, Manufacture, Distribution and Storage of Explosive Materials

202

WDMA

Window and Door Manufacturers Association
1400 East Touhy Avenue #470
Des Plaines IL 60018
Standard
reference
number
TitleReferenced
in code
section number

AAMA/WDMA/CSA 101/I.S.2/A440—11

Specifications for Windows, Doors and Unit Skylights

1710.5.1, 2405.5

WRI

Wire Reinforcement Institute, Inc.
942 Main Street, Suite 300
Hartford CT 06103
Standard
reference
number
TitleReferenced
in code
section number

WRI/CRSI—81

Design of Slab-on-ground Foundations—with 1996 Update

1808.6.2