301.1 Scope

AMENDMENT
This section has been amended at the state or city level.
The provisions of this chapter shall govern the minimum conditions for the maintenance of structures and equipment and for the maintenance of exterior property to the extent that this code is applicable.

301.2 Responsibility

AMENDMENT
This section has been amended at the state or city level.

301.3 Vacant Structures and Land

AMENDMENT
This section has been amended at the state or city level.
Vacant structures shall be maintained in a clean, safe, secure, and sanitary condition as provided for in this code.

302.1 Sanitation

AMENDMENT
This section has been amended at the state or city level.

302.2 Grading and Drainage

AMENDMENT
This section has been amended at the state or city level.
All premises shall be graded and maintained to protect the foundation walls or slab of the structure from the accumulation and drainage of surface or stagnant water in accordance with the applicable building code.

302.3 Sidewalks and Driveways

AMENDMENT
This section has been amended at the state or city level.
All sidewalks, walkways, stairs, driveways, parking spaces, and similar spaces regulated under the VCC shall be kept in a proper state of repair and maintained free from hazardous conditions.

302.4 Weeds

AMENDMENT
This section has been amended at the state or city level.

302.5 Rodent Harborage

AMENDMENT
This section has been amended at the state or city level.
All structures and adjacent premises shall be kept free from rodent harborage and infestation where such harborage or infestation adversely affects the structures.

302.6 Exhaust Vents

AMENDMENT
This section has been amended at the state or city level.
Accessory structures, including detached garages, fences and walls, shall be maintained structurally sound and in good repair.

302.8 Motor Vehicles

AMENDMENT
This section has been amended at the state or city level.

302.9 Defacement of Property

AMENDMENT
This section has been amended at the state or city level.
Swimming pools shall be maintained in a clean and sanitary condition, and in good repair.

303.2 Enclosures

AMENDMENT
This section has been amended at the state or city level.
Swimming pool, hot tub, and spa barriers shall be maintained as required by the code or ordinance under which such barriers were constructed.

304.1 General

AMENDMENT
This section has been amended at the state or city level.
The exterior of a structure shall be maintained in good repair, structurally sound, and sanitary so as not to pose a threat to the health, safety, or welfare.

304.1.1 Unsafe Conditions

AMENDMENT
This section has been amended at the state or city level.
Exterior surfaces, including but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences, shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. Siding and masonry joints, as well as those between the building envelope and the perimeter of windows, doors and skylights, shall be maintained weather resistant and water tight. Metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement.

304.3 Premises Identification

AMENDMENT
This section has been amended at the state or city level.
Address numbers of buildings shall be maintained when required by the applicable building code or when required by ordinance.
Structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads.
Foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests.
Exterior walls shall be free from holes, breaks, and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration.

304.7 Roofs and Drainage

AMENDMENT
This section has been amended at the state or city level.
The roof and flashing shall be sound, tight, and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof water shall be discharged in a manner to protect the foundation or slab of buildings and structures from the accumulation of roof drainage.
Cornices, belt courses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition.
Overhang extensions including, but not limited to, canopies, marquees, signs, metal awnings, fire escapes, standpipes and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. Where required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment.
Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads.
Chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. Exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weathercoating materials, such as paint or similar surface treatment.
Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight.
Glazing materials shall be maintained free from cracks and holes.
Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware.

304.14 Insect Screens

AMENDMENT
This section has been amended at the state or city level.
During the period from April 1 to December 1, every door, window, and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas, or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged, or stored shall be supplied with an approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 mm) and every screen door used for insect control shall have a self-closing device in good working condition.

Exception: Screens shall not be required where other approved means, such as mechanical ventilation, air curtains, or insect repellant fans, are used.
Exterior doors, door assemblies, operator systems if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3.
Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water.
Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.

304.18 Building Security

AMENDMENT
This section has been amended at the state or city level.
Devices designed to provide security for the occupants and property within, when required by the applicable building code, or when provided, shall be maintained unless their removal is approved by the building official under the VCC.

304.18.1 Doors

AMENDMENT
This section has been amended at the state or city level.

304.18.2 Windows

AMENDMENT
This section has been amended at the state or city level.

304.18.3 Basement Hatchways

AMENDMENT
This section has been amended at the state or city level.

304.19 Gates

AMENDMENT
This section has been amended at the state or city level.
To the extent required by the applicable building code or to the extent provided when constructed, exterior gates, gate assemblies, operator systems if provided, and hardware shall be maintained in good condition. Latches at all entrances shall tightly secure the gates.

305.1 General

AMENDMENT
This section has been amended at the state or city level.
The interior of a structure and equipment therein shall be maintained in good repair, structurally sound, and in a sanitary condition.

305.1.1 Unsafe Conditions

AMENDMENT
This section has been amended at the state or city level.
Structural members shall be maintained structurally sound, and be capable of supporting the imposed loads.
Interior surfaces, including windows and doors, shall be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. Cracked or loose plaster, decayed wood and other defective surface conditions shall be corrected.
Every stair, ramp, landing, balcony, porch, deck or other walking surface shall be maintained in sound condition and good repair.
Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.
Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware.

305.7 Carbon Monoxide Alarms

AMENDMENT
This section has been amended at the state or city level.
Carbon monoxide alarms shall be maintained as approved.

Section 306 Component Serviceability

AMENDMENT
This section has been amended at the state or city level.

306.1 General

AMENDMENT
This section has been amended at the state or city level.

306.1.1 Unsafe Conditions

AMENDMENT
This section has been amended at the state or city level.

307.1 General

AMENDMENT
This section has been amended at the state or city level.
Handrails and guards required by the applicable building code or which were provided when a building was constructed shall be maintained.

308.1 Accumulation of Rubbish or Garbage

AMENDMENT
This section has been amended at the state or city level.
The interior of every structure shall be free from excessive accumulation of rubbish or garbage.

308.2 Disposal of Rubbish

AMENDMENT
This section has been amended at the state or city level.

308.2.1 Rubbish Storage Facilities

AMENDMENT
This section has been amended at the state or city level.

308.2.2 Refrigerators

AMENDMENT
This section has been amended at the state or city level.

308.3 Disposal of Garbage

AMENDMENT
This section has been amended at the state or city level.

308.3.1 Garbage Facilities

AMENDMENT
This section has been amended at the state or city level.

308.3.2 Containers

AMENDMENT
This section has been amended at the state or city level.

Section 309 Pest Elimination Infestation and Extermination

AMENDMENT
This section has been amended at the state or city level.

309.1 Infestation

AMENDMENT
This section has been amended at the state or city level.
This section shall apply to the extent that insect and rodent infestation adversely affects a structure. All structures shall be kept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After extermination, proper precautions shall be taken to prevent reinfestation.

309.2 Owner

AMENDMENT
This section has been amended at the state or city level.

309.3 Single Occupant

AMENDMENT
This section has been amended at the state or city level.

309.4 Multiple Occupancy

AMENDMENT
This section has been amended at the state or city level.

309.5 Occupant

AMENDMENT
This section has been amended at the state or city level.

Section 310 Lead-Based Paint

AMENDMENT
This section has been amended at the state or city level.

310.1 General

AMENDMENT
This section has been amended at the state or city level.
Interior and exterior painted surfaces of dwellings and child care facilities, including fences and outbuildings, that contain lead levels equal to or greater than 1.0 milligram per square centimeter or in excess of 0.50% lead by weight shall be maintained in a condition free from peeling, chipping, and flaking paint or removed or covered in an approved manner. Any surface to be covered shall first be identified by an approved warning as to the lead content of such surface.

Section 311 Aboveground Liquid Fertilizer Storage Tanks (ALFST)

AMENDMENT
This section has been amended at the state or city level.

311.1 General

AMENDMENT
This section has been amended at the state or city level.
ALFSTs shall be maintained in accordance with the requirements of Section 1101.16 of the VEBC and the requirements of the VCC applicable to such ALFSTs when newly constructed and the requirements of the VEBC when undergoing a change of occupancy to an ALFST and when repaired, altered, or reconstructed, including the requirements for inspections and for a secondary containment system.