CODES

ADOPTS WITH AMENDMENTS:

International Plumbing Code 2015 (IPC 2015)

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A118.10‒99 Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set
Ceramic Tile and Dimension Stone Installation
417.5.2.5, 417.5.2.6
Z4.3‒95 Minimum Requirements for Nonsewered Waste-disposal Systems 311.1
Z21.22‒99 (R2003) Relief Valves for Hot Water Supply Systems with Addenda Z21.22a‒2000 (R2003) and
Z21.22b‒2001 (R2003)
504.2, 504.4, 504.4.1
CSA B45.5‒11/
IAPMO Z124‒11
Plastic Plumbing Fixtures 407.1, 415.1, 416.1, 416.2, 417.1, 418.1, 419.1, 420.1

AHRI Air-Conditioning, Heating, & Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
reference
number
Title Referenced
in code
section number
1010‒02 Self-contained, Mechanically Refrigerated Drinking-Water Coolers 410.1

API American Petroleum Institute
1220 L Street NW
Washington, DC 20005-4070
Standard
reference
number
Title Referenced
in code
section number
12D‒2008 Specification for Field Welded Tanks for Storage of Production Liquids, effective April 1, 2009 1302.7.2
12F‒2008 Specification for Shop Welded Tanks for Storage of Production Liquids, effective April 1 2009 1302.7.2

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A112.1.2‒2004 Air Gaps in Plumbing Systems 406.1, 409.2, Table 608.1, 608.13.1
A112.1.3‒2000
(R2011)
Air Gap Fittings for Use with Plumbing Fixtures,
Appliances and Appurtenances
406.1, 409.2, Table 608.1, 608.13.1, 1102.6
A112.3.1‒2007 Stainless Steel Drainage Systems for Sanitary, DWV, Storm and
Vacuum Applications Above and Below Ground
412.1, Table 702.1, Table 702.2, Table
702.3, Table 702.4, Table 1102.4,
Table 1102.5, 1102.6, Table 1102.7
ASME A112.3.4‒2013/
CSA B45.9‒2013
Macerating Toilet Systems and Related Components 712.4.1
A112.4.1‒2009 Water Heater Relief Valve Drain Tubes 504.6
A112.4.2‒2009 Water Closet Personal Hygiene Devices 424.9
A112.4.3‒1999 (R2010) Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System 405.4
A112.4.14‒2004 (R2010) Manually Operated, Quarter-Turn Shutoff Valves for Use in Plumbing Systems Table 605.7
A112.14.6‒2010 FOG (Fats, Oils and Greases) Disposal Systems 1003.3.4, 1003.3.6
A112.6.1M‒1997 (R2008) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use 405.4.3
A112.6.2‒2000 (R2010) Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks 405.4.3
A112.6.3‒2001 (R2007) Floor and Trench Drains 412.1
A112.6.4‒2003 (R2008) Roof, Deck, and Balcony Drains 1102.6
A112.6.7‒2010 Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks 427.1
A112.6.9‒2005 (R2010) Siphonic Roof Drains 1107.1
A112.14.1‒2003 Backwater Valves 715.2
A112.14.3‒2000 Grease Interceptors 1003.3.4
A112.14.4‒2001
(Reaffirmed 2007)
Grease Removal Devices 1003.3.4
A112.18.1‒2012/
CSA B125.1‒2012
Plumbing Supply Fittings 424.1, 424.2, 424.3, 424.4, 424.6, 424.8, 605.7, 607.4, 608.2
A112.18.2‒2011/
CSA B125.2‒2011
Plumbing Waste Fittings 424.1.2
A112.18.3‒2002
(Reaffirmed 2008)
Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings
424.2, 424.6
A112.18.6/
CSA B125.6‒2009
Flexible Water Connectors 605.6
A112.18.9‒2011 Protectors/Insulators for Exposed Waste and Supplies on Accessible Fixtures 404.3
A112.19.1/‒2013
CSA B45.2‒2013
Enameled Cast Iron and Enameled Steel Plumbing Fixtures 407.1, 410.1, 415.1, 416.1, 418.1
A112.19.2‒2013/
CSA B45.1‒13
Ceramic Plumbing Fixtures 401.2, 405.9, 407.1, 408.1, 410.1, 415.1, 416.1, 417.1, 418.1, 419.1, 420.1
A112.19.3‒2008/
CSA B45.4‒08(R2013)
Stainless Steel Plumbing Fixtures 405.9, 407.1, 415.1, 416.1, 418.1, 420.1
A112.19.5/‒2011
CSA B45.15‒2011
Flush Valves and Spuds for Water-closets, Urinals, and Tanks 425.4
A112.19.7M‒2012/
CSA B45.10‒2012
Hydromassage Bathtub Systems 421.1, 421.4
A112.19.12‒2006 Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and
Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems
416.4, 418.3
A112.19.14-2006(R2011) Six-Liter Water Closets Equipped with a Dual Flushing Device 420.1
A112.19.15‒2005 Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors 407.4, 421.6
A112.19.19‒2006 Vitreous China Nonwater Urinals 419.1
A112.21.3-1985(R2007) Hydrants for Utility and Maintenance Use Table 608.1, 608.13.6
A112.36.2M‒1991
(R2008)
Cleanouts 708.1.10.2
ASSE 1016/
ASME A112.1016/
CSA B125.16-2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
424.3, 424.4, 607.4
B1.20.1‒1983(R2006) Pipe Threads, General Purpose (inch) 605.10.3, 605.11.3, 605.13.4, 605.15.3,
605.18.1, 605.22.4, 705.2.3, 705.3.3,
705.6.4, 705.19.1, 705.11.3
B 16.3‒2011 Malleable Iron Threaded Fittings Classes 150 and 300 Table 702.4, Table 1102.7
B 16.4‒2011 Gray Iron Threaded Fittings Classes 125 and 250 Table 605.5, Table 702.4, Table 1102.7
B 16.9‒2007 Factory-made Wrought Steel Buttwelding Fittings Table 605.5, Table 702.4, Table 1102.7
B 16.11‒2011 Forged Fittings, Socket-welding and Threaded Table 605.5, Table 702.4, Table 1102.7
B 16.12‒2009 Cast-iron Threaded Drainage Fittings Table 702.4, Table 1102.7
B 16.15‒2011 Cast Bronze Threaded Fittings Table 605.5, Table 702.4, Table 1102.7
B 16.18‒2012 Cast Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4, Table 1102.7
B 16.22‒2001(R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4, Table 1102.7
B 16.23‒2011 Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 702.4, Table 1102.7
B 16.26‒2011 Cast Copper Alloy Fittings for Flared Copper Tubes Table 605.5, Table 702.4, Table 1102.7
B 16.28‒1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 605.5,
Table 702.4, Table 1102.7
B 16.29‒2012 Wrought Copper and Wrought Copper Alloy Solder
Joint Drainage Fittings (DWV)
Table 702.4, Table 1102.7
B16.34‒2009 Valves Flanged, Threaded and Welding End Table 605.7
B16.51‒2011 Copper and Copper Alloy Press-Connect Pressure Fittings Table 605.5

ASPE American Society of Plumbing Engineers
8614 Catalpa Avenue, Suite 1007
Chicago, IL 60656-1116
Standard
reference
number
Title Referenced
in code
section number
45‒2013 Siphonic Roof Drainage Systems 1107.1

ASSE American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1001‒08 Performance Requirements for Atmospheric Type Vacuum Breakers 425.2, Table 608.1,
608.13.6, 608.16.4.1
1002‒08 Performance Requirements for Antisiphon Fill Valves (Ballcocks) for
Gravity Water Closet Flush Tanks
425.3.1, Table 608.1
1003‒09 Performance Requirements for Water Pressure Reducing Valves 604.8
1004‒08 Performance Requirements for Backflow Prevention Requirements for
Commercial Dishwashing Machines
409.1
1005‒99 Performance Requirements for Water Heater Drain Valves 501.3
1008‒06 Performance Requirements for Plumbing Aspects of Food Waste Disposer Units 413.1
1010‒04 Performance Requirements for Water Hammer Arresters 604.9
1011‒04 Performance Requirements for Hose Connection Vacuum Breakers Table 608.1, 608.13.6
1012‒09 Performance Requirements for Backflow Preventers with Intermediate
Atmospheric Vent
Table 608.1, 608.13.3, 608.16.2
1013‒09 Performance Requirements for Reduced Pressure Principle Backflow
Preventers and Reduced Pressure Principle Fire Protection
Backflow Preventers
Table 608.1, 608.13.2, 608.16.2
1015‒09 Performance Requirements for Double Check Backflow Prevention
Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.13.7
ASSE 1016/
ASME A112.1016/
CSA B125.16‒2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
424.3, 424.4, 607.4
1017‒2010 Performance Requirements for Temperature Actuated Mixing Valves for
Hot Water Distribution Systems
501.2, 613.1
1018‒2010 Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied 1002.4.1.2
1019‒2010 Performance Requirements for Vacuum Breaker Wall Hydrants,
Freeze Resistant, Automatic Draining Type
Table 608.1, 608.13.6, 608.13.10
1020‒04 Performance Requirements for Pressure Vacuum Breaker Assembly Table 608.1, 608.13.5
1022‒03 Performance Requirements for Backflow Preventer for Beverage
Dispensing Equipment
Table 608.1, 608.16.1, 608.16.10
1024‒04 Performance Requirements for Dual Check Valve Type Backflow Preventers
(for Residential Supply Service or Individual Outlets)
605.3.1, Table 608.1, 608.13.10
1035‒08 Performance Requirements for Laboratory Faucet Backflow Preventers Table 608.1, 608.13.6
1037‒90 Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures 425.2
1044‒2010 Performance Requirements for Trap Seal Primer Devices Drainage Types and
Electronic Design Types
1002.4.1.3
1047‒2009 Performance Requirements for Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies
Table 608.1, 608.13.2
1048‒2009 Performance Requirements for Double Check Detector Fire Protection
Backflow Prevention Assemblies
Table 608.1, 608.13.7
1049‒2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for
Chemical Waste Systems
901.3, 918.8
1050‒2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems 918.1
1051‒2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for
Sanitary Drainage Systems-fixture and Branch Devices
918.1
1052‒04 Performance Requirements for Hose Connection Backflow Preventers Table 608.1, 608.13.6
1055‒2009 Performance Requirements for Chemical Dispensing Systems 608.13.9
1056‒2010 Performance Requirements for Spill Resistant Vacuum Breaker Table 608.1, 608.13.5, 608.13.8
1060‒2006 Performance Requirements for Outdoor Enclosures for Fluid Conveying Components 608.14.1
1061‒2010 Performance Requirements for Removable and Nonremovable Push Fit Fittings Table 605.5
1062‒2006 Performance Requirements for Temperature Actuated, Flow Reduction Valves to
Individual Supply Fittings
424.7
1066‒2009 Performance Requirements for Individual Pressure Balancing In-line Valves for
Individual Fixture Fittings
604.11
1069‒05 Performance Requirements for Automatic Temperature Control Mixing Valves 424.4
1070‒04 Performance Requirements for Water-temperature Limiting Devices 408.3, 416.5, 423.3, 424.5, 607.1.2
1072‒07 Performance Requirements for Barrier Type Floor Drain Tap Seal Protection Devices 1002.4.14
1079‒2005 Performance Requirements for Dielectric Pipe Unions 605.24.1, 605.24.3
5013‒2009 Performance Requirements for Testing Reduced Pressure Principle Backflow
Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)
312.10.2
5015‒2009 Performance Requirements for Testing Double Check Valve Backflow Prevention
Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF)
312.10.2
5020‒2009 Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA) 312.10.2
5047‒98 Performance Requirements for Testing Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies (RPDA)
312.10.2
5048‒2009 Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA) 312.10.2
5052‒98 Performance Requirements for Testing Hose Connection Backflow Preventers 312.10.2
5056‒98 Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB) 312.10.2

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M‒12 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated
Welded and Seamless
Table 605.3, Table 605.4, Table 702.1
A 74‒13A Specification for Cast-iron Soil Pipe and Fittings Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 708.2, 708.7, Table 1102.4,
Table 1102.5, Table 1102.7
A 312/A 312M‒13a Specification for Seamless, Welded, And Heavily Cold Worked Austenitic
Stainless Steel Pipes
Table 605.3, Table 605.4,
Table 605.5, 605.23.2
A 733‒2003(2009)e1 Specification for Welded and Seamless Carbon Steel and Austenitic
Stainless Steel Pipe Nipples
Table 605.8
A 778‒01(2009)e1 Specification for Welded Unannealed Austenitic Stainless Steel
Tubular Products
Table 605.3, Table 605.4, Table 605.5
A 888‒13A Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste, and Vent Piping Application
Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 708.7, Table 1102.4,
Table 1102.5, Table 1102.7
B 32‒08 Specification for Solder Metal 605.13.3, 605.14.6, 705.6.3, 705.17.3
B 42‒10 Specification for Seamless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 43‒09 Specification for Seamless Red Brass Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 75‒11 Specification for Seamless Copper Tube Table 605.3, Table 605.4, Table 702.1,
Table 702.2, Table 702.3, Table 1102.4
B 88‒09 Specification for Seamless Copper Water Tube Table 605.3, Table 605.4, Table 702.1,
Table 702.2, Table 702.3, Table 1102.4
B 152/B 152M‒13 Specification for Copper Sheet, Strip Plate and Rolled Bar 402.3, , 417.5.2.4, 425.3.3, 902.2
B 251‒10 Specification for General Requirements for Wrought Seamless Copper
and Copper-alloy Tube
Table 605.3, Table 605.4, Table 702.1,
Table 702.2, Table 702.3, Table 1102.4
B 302‒12 Specification for Threadless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 306‒09 Specification for Copper Drainage Tube (DWV) Table 702.1, Table 702.2, Table 1102.4
B 447‒12a Specification for Welded Copper Tube Table 605.3, Table 605.4
B 687‒99(2011) Specification for Brass, Copper and Chromium-plated Pipe Nipples Table 605.8
B 813‒10 Specification for Liquid and Paste Fluxes for Soldering of Copper and
Copper Alloy Tube
605.13.3, 605.14.6, 705.6.3, 705.7.3
B 828‒02(2010) Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
605.13.3, 605.14.6, 705.6.3, 705.17.3
C 4‒04(2009) Specification for Clay Drain Tile and Perforated Clay Drain Tile Table 702.3, Table 1102.4, Table 1102.5
C 14‒11 Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe Table 702.3, Table 1102.4
C 76‒13a Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe Table 702.3, Table 1102.4
C 425‒04(2009) Specification for Compression Joints for Vitrified Clay Pipe and Fittings 705.12, 705.16
C 443‒12 Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets 705.5, 705.16
C 564‒12 Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings 705.4.2, 705.4.3, 705.16
C 700‒13 Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and
Perforated
Table 702.3, Table 702.4,
Table 1102.4, Table 1102.5C 1053‒00(2010)
C 1053‒00(2010) Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and
Vent (DWV) Applications
Table 702.1, Table 702.4
C 1173‒10e1 Specification for Flexible Transition Couplings for Underground Piping System 705.2.1, 705.5,
705.11.1, 705.12, 705.13.2, 705.16
C 1277‒12 Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings 705.4.3
C 1440‒08 Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain,
Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
705.16
C 1460‒08 Specification for Shielded Transition Couplings for Use with Dissimilar DWV
Pipe and Fittings Above Ground
705.16
C 1461‒08 Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE)
Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing
Systems for Above and Below Ground Use
705.19
C 1540‒11 Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings 705.4.3
C 1563‒13 Standard Test Method for Gaskets for Use in Connection with Hub and Spigot
Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications
705.4.2
D 1253‒08 Standard Test Method For Residual Chlorine in Water 1301.2.1, 1303.9
D 1527‒99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 605.3
D 1785‒12 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 605.3
D 2235‒04(2011) Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
605.10.2, 705.2.2, 705.2.2, 705.7.2
D 2239‒12a Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on
Controlled Inside Diameter
Table 605.3
D 2241‒09 Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series) Table 605.3
D 2282‒99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 605.3
D 2464‒06 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings,
Schedule 80
Table 605.5
D 2466‒06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 Table 605.5
D 2467‒06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 605.5
D 2468‒96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings,
Schedule 40
Table 605.5
D 2564‒12 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC)
Plastic Piping Systems
605.22.3, 705.11.2, 705.14.2
D 2609‒02(2008) Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe Table 605.5
D 2657‒07 Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Waste,
and Vent Pipe and Fittings
605.19.2, 705.13.1
D 2661‒11 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40
Plastic Drain, Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 705.2.2, 705.7.2,
Table 1102.4, Table 1102.7
D 2665‒12 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste,
and Vent Pipe and Fittings
Table 702.1, Table 702.2,
Table 702.3, Table 702.4,
Table 1102.4, Table 1102.7
D 2672‒96a(2009) Specification for Joints for IPS PVC Pipe Using Solvent Cement Table 605.3
D 2683‒10e1 Standard Specification for Socket-type Polyethylene fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
Table 605.5, 717.5
D 2729‒11 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 1102.5, Table 1403.2
D 2737‒2012a Specification for Polyethylene (PE) Plastic Tubing Table 605.3
D 2751‒05 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe
and Fittings
Table 702.3, Table 702.4,
Table 1102.4, Table 1102.7
D 2846/D 2846M‒09be1 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and
Cold Water Distribution Systems
Table 605.3, Table 605.4,
Table 605.5, 605.15.2, 605.16.2
D 2855‒96(2010) Standard Practice for Making Solvent-cemented Joints with
Poly (Vinyl Chloride) (PVC) Pipe and Fittings
605.22.3, 705.11.2
D 2949‒10 Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC)
Plastic Drain, Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3,
Table 702.4, Table 1102.7
D 3034‒08 Specification for Type PSM Poly (Vinyl Chloride) (PVC)
Sewer Pipe and Fittings
Table 702.3, Table 702.4,
Table 1102.4, Table 1102.5, Table 1102.7
D 3035‒2012e1 Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on
Controlled Outside Diameter
Table 605.3
D 3139‒98(2011) Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals 605.10.1, 605.22.1
D 3212‒07 Specification for Joints for Drain and Sewer Plastic Pipes Using
Flexible Elastomeric Seals
705.2.1, 705.11.1, 705.13.2
D 3261‒12 Specification for Butt Heat Fusion Polyethylene (PE) Plastic fittings
for Polyethylene (PE) Plastic Pipe and Tubing
Table 605.5
D 3311‒11 Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns Table 1102.7
D 4068‒09 Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed
Water-containment Membrane
417.5.2.2
D 4551‒12 Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed
Water-containment Membrane
417.5.2.1
E 2635‒08 Standard Practice for Water Conservation in Buildings Through In-Situ Water Reclamation 1304.3
E 2727‒10 Standard Practice for the Assessment of Rainwater Quality 1302.8.1
F 405‒05 Specification for Corrugated Polyethylene (PE) Pipe and Fittings Table 1102.5, Table 1403.2
F 409‒12 Specification for Thermoplastic Accessible and Replaceable Plastic Tube
and Tubular Fittings
424.1.2, Table 1102.7
F 437‒09 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 80
Table 605.5
F 438‒09 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 40
Table 605.5
F 439‒12 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 80
Table 605.5
F 441/F 441M‒13 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,
Schedules 40 and 80
Table 605.3, Table 605.4
F 442/F 442M‒13 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe (SDR-PR)
Table 605.3, Table 605.4
F 477‒10 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe 605.24,705.16
F 493‒10 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe and Fittings
605.15.2, 605.16.2
F 628‒08 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic
Drain, Waste, and Vent Pipe with a Cellular Core
Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 705.2.2, Table 1102.4, Table 1102.7
F 656‒10 Specification for Primers for Use in Solvent Cement Joints of
Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings
.605.22.3, 705.11.2, 705.14.2
F 714‒2013 Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter Table 702.3, 717.4
F 876‒2013 Specification for Cross-linked Polyethylene (PEX) Tubing Table 605.3, Table 605.4
F 877‒2011a Specification for Cross-linked Polyethylene (PEX) Plastic Hot and
Cold Water Distribution Systems
Table 605.3, Table 605.4, Table 605.5
F 891‒10 Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe
with a Cellular Core
Table 702.1 Table 702.2, Table 702.3,
Table 1102.4, Table 1102.5, Table 1102.7
F 1055‒13 Standard Specification for Electrofusion Type Polyethylene Fittings for
Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing
Table 605.5
F 1281‒11 Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene
(PEX-AL-PEX) Pressure Pipe
Table 605.3, Table 605.4, Table 605.5, 605.21.1
F 1282‒10 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
Table 605.3, Table 605.4, Table 605.5, 605.21.1
F 1412‒09 Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Table 702.1, Table 702.2,
Table 702.4, 705.14.1, 901.3
F 1476‒07 Standard Specification for Performance of Gasketed Mechanical Couplings for
Use in Piping Applications
Table 605.5, 605.14.3,
605.18.3, 605.22.2, 605.23.3
F 1488‒09e1 Specification for Coextruded Composite Pipe Table 702.1, Table 702.2, Table 702.3, Table 1403.2
F 1548‒01(2006) Standard Specification for the Performance of Fittings for Use with
Gasketed Mechanical Couplings Used in Piping Applications
Table 605.5
F 1673‒10 Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 705.15.1
F 1807‒13 Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of
Raised Temperature (PE-RT) Tubing
Table 605.5
F 1866‒07 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and
DWV Fabricated Fittings
Table 702.4, Table 1102.7
F 1960‒12 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for use with
Cross-linked Polyethylene (PEX) Tubing
Table 605.5
F 1970‒12 Special Engineered Fittings, Appurtenances or Valves for use in Poly (Vinyl Chloride) (PVC)
OR Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
Table 605.7
F 1974‒09 Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite
Pressure Pipe
Table 605.5, 605.21.1
F 1986‒01(2011) Specification for Multilayer Pipe, Type 2, Compression Fittings and
Compression Joints for Hot and Cold Drinking Water Systems
Table 605.3, Table 605.4, Table 605.5
F 2080‒12 Specifications for Cold-expansion Fittings with Metal Compression-sleeves for
Cross-linked Polyethylene (PEX) Pipe
Table 605.5
F 2098‒08 Standard specification for Stainless Steel Clamps for Securing SDR9 Cross-linked
Polyethylene (PEX) Tubing to Metal and Plastic Insert Fittings
Table 605.5
F 2159‒11 Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked
Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
Table 605.5
F 2262‒09 Specification for Cross-linked Polyethylene/Aluminum/
Cross-linked Polyethylene Tubing OD Controlled SDR9
Table 605.3, Table 605.4
F 2306/F 2306M‒13 12'' to 60'' Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for
Gravity Flow Storm Sewer and Subsurface Drainage Applications
Table 1102.4, Table 1102.7
F 2389‒10 Specification for Pressure-rated Polypropylene (PP) Piping Systems Table 605.3, Table 605.4,
Table 605.5, Table 605.7, 605.20.1
F 2434‒09 Standard Specification for Plastic Insert Fittings Utilizing a
Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9
Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX AL-PEX) Tubing
Table 605.5
F 2735‒09 Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX)
and Polyethylene of Raised Temperature (PE-RT) Tubing
Table 605.5
F 2769‒10 Polyethylene or Raised Temperature (PE-RT) Plastic Hot and
Cold Water Tubing and Distribution Systems
Table 605.3, Table 605.4, Table 605.5
F 2831‒11 Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used
In Rehabilitation of Metallic Pressurized Piping Systems
601.5
F 2855‒11 Specification Poly (Vinyl Chloride)/Aluminum/Poly (Vinyl Chloride) (CPVC/AL/CPVC)
Composite Pressure Tubing
Table 605.3, Table 605.4

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
Standard
reference
number
Title Referenced
in code
section number
A5.8M/A5.8‒2011 Specifications for Filler Metals for Brazing and Braze Welding 605.11.1, 605.13.1,
605.14.1, 705.3.1, 705.6.1, 705.7.1

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C104/A21.4-08 Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water 605.3, 605.5
C110/A21.10‒12 Ductile-iron and Gray-iron Fittings Table 605.5, Table 702.4, Table 1102.7
C111/A21.11-12 Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings 605.12
C115/A21.15‒11 Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges Table 605.3, Table 605.4
C151/A21.51‒09 Ductile-iron Pipe, Centrifugally Cast for Water Table 605.3, Table 605.4
C153‒00/A21.53‒11 Ductile-iron Compact Fittings for Water Service Table 605.5
C500‒09 Standard for Metal-Seated Gate Valves for Water Supply Service Table 605.7
C504‒10 Standard for Rubber-Seated Butterfly Valves Table 605.7
C507‒11 Standard for Ball Valves, 6 In. Through 60 In Table 605.7
C510‒07 Double Check Valve Backflow Prevention Assembly Table 608.1, 608.13.7
C511‒07 Reduced-pressure Principle Backflow Prevention Assembly Table 608.1, 608.13.2, 608.16.2
C651‒05 Disinfecting Water Mains 610.1
C652‒11 Disinfection of Water-storage Facilities 610.1
C901‒08 Polyethylene (PE) Pressure Pipe and Tubing 1/2 inch (13 mm)
Through 3 inch (76 mm) for Water Service
Table 605.3
C904‒08 Cross-linked Polyethylene (PEX) Pressure Pipe 1/2 inch (13 mm)
Through 3 inch (76 mm) for Water Service
Table 605.3
D100‒05 Standard for Welded Carbon Steel Tanks for Water Storage 1302.7.2
D115‒06 Standard for Tendon Prestressed-Concrete Water Tanks 1302.7.2
D120‒09 Standard for Thermosetting Fiberglass-Reinforced Plastic Tanks 1302.7.2

CISPI Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
Standard
reference
number
Title Referenced
in code
section number
301‒04a Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
Table 702.1, Table 702.2, Table 702.3,
Table 702.4, 708.7, Table 1102.4,
Table 1102.5, Table 1102.7
310‒04 Specification for Coupling for Use in Connection with Hubless Cast-iron
Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
705.4.3

CSA CSA Group
8501 East Pleasant Valley
Cleveland, OH 44131-5516
Standard
reference
number
Title Referenced
in code
section number
A257.1M‒2009 Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
A257.2M‒2009 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
A257.3M‒2009 Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and
Fittings Using Rubber Gaskets
705.5, 705.16
ASME A112.18.1‒2012/
CSA B125.1‒2012
Plumbing Supply Fittings 424.1, 424.2, 424.3, 424.4, 424.6, 424.8, 605.7, 607.4, 608.2
ASME A112.18.2‒2011/
CSA B125.2‒2011
Plumbing Waste Fittings 424.1.2
ASME A112.19.2‒2013/
B45.1‒2013
Ceramic Plumbing Fixtures 401.2, 405.9, 407.1, 408.1, 410.1, 415.1, 416.1, 417.1,
418.1, 419.1, 420.1
ASME A112.19.1‒2013/
CSA B45.2‒2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures 407.1, 410.1, 415.1, 416.1, 418.1
ASME A112.19.3‒2008/
CSA B45.4‒08(R2013)
Stainless-steel Plumbing Fixtures 405.9, 407.1, 415.1, 416.1, 418.1, 420.1
ASME A112.19.5‒2011/
CSA B45.15‒2011
Flush Valves and Spuds for Water Closets, Urinals and Tanks 425.4
ASME A112.19.7‒2012/
CSA B45.10‒2012
Hydromassage Bathtub Systems 421.1, 421.4
CSA B45.5‒11/
IAPMO Z124-2011
Plastic Plumbing Fixtures 407.1, 415.1, 416.1, 416.2, 417.1, 419.1, 420.1
ASME A112.3.4‒2013/
CSA B45.9‒2013
Macerating Systems and Related Components 712.4.1
ASSE 1016/
ASME A112.1016/
CSA B125.16‒2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
424.3, 424.4, 607.4
B64.1.1‒11 Vacuum Breakers, Atmospheric Type (AVB) 425.2, Table 608.1, 608.13.6, 608.16.4.1
B64.1.2‒11 Pressure Vacuum Breakers, (PVB) Table 608.1, 608.13.5
B64.1.3‒11 Spill Resistant Pressure Vacuum Breakers (SRPVB) 608.13.8
B64.2‒11 Vacuum Breakers, Hose Connection Type (HCVB) Table 608.1, 608.13.6
B64.2.1‒11 Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature Table 608.1, 608.13.6
B64.2.1.1‒11 Hose Connection Dual Check Vacuum Breakers, (HCDVB) Table 608.1, 608.13.6
B64.2.2‒11 Vacuum Breakers, Hose Connection Type (HCVB) with
Automatic Draining Feature
Table 608.1, 608.13.6
B64.3‒11 Backflow Preventers, Dual Check Valve Type with
Atmospheric Port (DCAP)
Table 608.1, 608.13.3, 608.16.2
B64.4‒11 Backflow Preventers, Reduced Pressure Principle Type (RP) Table 608.1, 608.13.2, 608.16.2
B64.4.1‒11 Reduced Pressure Principle for Fire Sprinklers (RPF) Table 608.1, 608.13.2
B64.5‒11 Double Check Backflow Preventers (DCVA) Table 608.1, 608.13.7
B64.5.1‒11 Double Check Valve Backflow Preventer for Fire Systems (DCVAF) Table 608.1 608.13.7
B64.6‒11 Dual Check Backflow PreventersValve (DuC) 605.3.1, Table 608.1, 608.13.10
B64.7‒11 Laboratory Faucet Vacuum Breakers (LFVB) Table 608.1, 608.13.6
B64.10‒11 Manual for the Selection and Installation of Backflow Prevention Devices 312.10.2
B64.10.1‒11 Maintenance and Field Testing of Backflow Preventers 312.10.2
B79‒08(R2013) Commercial and Residential Drains, and Cleanouts 412.1
B125.3‒2012 Plumbing Fittings 408.3, 416.5, 423.3, 424.4, 424.5, 425.2, 425.3.1, Table 605.7, Table 608.1
B137.1‒13 Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services Table 605.3, Table 605.5
B137.2‒13 Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications Table 605.5
B137.3‒13 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications Table 605.3
Table 605.5, 605.22.3, 705.11.2, 705.14.2
B137.5‒13 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications Table 605.3,
Table 605.4, Table 605.5
B137.6‒13 CPVC Pipe, Tubing and Fittings for Hot and
Cold Water Distribution Systems
Table 605.3, Table 605.4, Table 605.5
B137.9‒13 Polyethylene/Aluminum/
Polyethylene Composite Pressure Pipe Systems
Table 605.3, Table 605.5, 605.21.1
B137.10‒13 Cross-linked Polyethylene/Aluminum/
Polyethylene Composite Pressure Pipe Systems
Table 605.3, Table 605.4, Table 605.5, 605.21.1
B137.11‒13 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Table 605.3, Table 605.4, Table 605.5
B181.1‒11 Acrylonitrile-butadiene-styrene ABS Drain,
Waste and Vent Pipe and Pipe Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4,
705.2.2, 715.2, Table 1102.4, Table 1102.7
B 181.2‒11 Polyvinylchloride PVC and chlorinated polyvinylchloride (CPVC)
Drain, Waste, and Vent Pipe and Pipe Fittings
Table 702.1 Table 702.2, 705.11.2, 705.14.2, 715.2
B 181.3‒11 Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems Table 702.1, Table 702.2,
Table 702.3, Table 702.4, 705.14.1
B182.1‒11 Plastic Drain and Sewer Pipe and Pipe Fittings 705.11.2, 705.14.2, Table 1102.4, Table 1102.5
B182.2‒11 PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings Table 702.3, Table 1102.4, Table 1102.5
B182.4‒11 Profile Polyvinylchloride PVC Sewer Pipe and Fittings Table 702.3, Table 1102.4, Table 1102.5
B182.6‒11 Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-proof Sewer Applications Table 1102.5
B182.8‒11 Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings Table 1102.5
B356‒10 Water Pressure Reducing Valves for Domestic Water Systems 604.8
B483.1‒14 Drinking Water Treatment Units 611.1, 611.2
B481.1‒12 Testing and Rating of Grease interceptors Using Lard 1003.3.4
B481.3‒12 Sizing, Selection, Location and Installation of Grease Interceptors 1003.3.4
B602‒10 Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe 705.2.1, 705.4.3, 705.5, 705.11.1,
705.12, 705.13.2, 705.16

IAPMO IAPMO Group
4755 E. Philadelphia
Ontario, CA 91761
Standard
reference
number
Title Referenced
in code
section number
Z1001-2007 Prefabricated Gravity Grease Interceptors 1003.3.6
CSA B45.5‒11/
IAPMO Z124-2011
Plastic Plumbing Fixtures 407.1, 415.1, 416.1, 416.2, 417.1, 419.1, 420.1

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
A117.1‒2009 Accessible and Usable Buildings and Facilities 404.2
IBC‒15 International Building Code® .201.3, 307.1, 307.2, 307.3, 308.2, 309.1, 309.2, 310.1,
310.3, 315.1, 403.1, Table 403.1, 403.4, 404.1, 407.3, 417.6,
502.4, 606.5.2, 1106.5, 1301.9.4, 1307.7.2, 1303.6, 1402.1
IECC‒15 International Energy Conservation Code® 313.1, 607.5
IFC‒15 International Fire Code® 201.3, 1201.1
IFGC‒15 International Fuel Gas Code® 101.2, 201.3, 502.1, 502.1.1
IMC‒15 International Mechanical Code® 201.3, 307.7, 310.1, 422.9, 502.1, 502.1.1, 612.1, 1202.1
IPSDC‒15 International Private Sewage Disposal Code® 701.2
IRC‒15 International Residential Code® 101.2

ISEA International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington, VA 22209
Standard
reference
number
Title Referenced
in code
section number
ANSI/ISEA Z358.1‒2009 Emergency Eyewash and Shower Equipment 411.1

MSS Manufacturers Standardization Society Of the Valve and Fittings Industry, Inc.
127 Park St. NE
Vienna, VA 22180-4602
Standard
reference
number
Title Referenced
in code
section number
SP-67‒2011 Butterfly Valves Table 605.7
SP-70‒2011 Gray Iron Gate Valves, Flanged and Threaded Ends Table 605.7
SP-71‒2011 Gray Iron Swing Check Valves, Flanged and Threaded Ends Table 605.7
SP-72‒2010 Ball Valves with Flanged or Butt-Welding Ends for General Service Table 605.7
SP-78‒2011 Cast Iron Plug Valves, Flanged and Threaded Ends Table 605.7
SP-80‒2008 Bronze Gate, Globe, Angle and Check Valves Table 605.7
SP-110‒2010 Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends Table 605.7

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
51‒13 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes 1203.1
55‒13 Compressed Gases and Cryogenic Fluids Code 1203.1
70‒14 National Electric Code 502.1, 504.3, 1113.1.3
99‒15 Health Care Facilities Code 1202.1

NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
Standard
reference
number
Title Referenced
in code
section number
3‒2010 Commercial Warewashing Equipment 409.1
14‒2011 Plastic Piping System Components and Related Materials 303.3, 611.3
18‒2012 Manual Food and Beverage Dispensing Equipment 426.1
42‒2011 Drinking Water Treatment Units-Aesthetic Effects 611.1, 611.3
44‒2012 Residential Cation Exchange Water Softeners .611.1, 611.3
50‒2012 Equipment for Swimming Pools, Spas, Hot Tubs and other Recreational Facilities 1302.8.1
53‒2011a Drinking Water Treatment Units‒Health Effects 611.1, 611.3
58‒2012 Reverse Osmosis Drinking Water Treatment Systems 611.2, 611.3
61‒2012 Drinking Water System Components‒Health Effects 410.1, 424.1, 605.3, 605.4, 605.5, 605.7, 611.3
62‒2012 Drinking Water Distillation Systems 611.1
350‒2011 Onsite Residential and Commercial Water Reuse Treatment Systems 1302.6.1
359‒2011 Valves for Crosslinked Polyethylene (PEX) Water Distribution Tubing Systems Table 605.7
372‒2010 Drinking Water Systems Components‒Lead Content 605.2.1

PDI Plumbing and Drainage Institute
800 Turnpike Street, Suite 300
North Andover, MA 01845
Standard
reference
number
Title Referenced
in code
section number
PDI G101 (2012) Testing and Rating Procedure for Grease Interceptors with
Appendix of Sizing and Installation Data
1003.3.4
PDI G102 (2009) Testing and Certification for Grease Interceptors with Fog Sensing and Alarm Devices 1003.3.4

USC University of Southern California
Kaprielian Hall
300 Los Angeles CA 90089-2531
Standard
reference
number
Title Referenced
in code
section number
USC-FCCCHR 10th Edition Manual of Cross Connection Control Foundation for Cross-Connection Control and Hydraulic Research University of Southern California Kaprielian Hall 300 Los Angeles CA 90089-2531 Table 608.1
Resources