International Existing Building Code 2015 (IEBC 2015)

ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
Standard
reference
number
Title Referenced
in code
section number
7‒10 Minimum Design Loads for Buildings and Other Structures with Supplement No. 1 A104, A403.3
41‒13 Seismic Rehabilitation of Existing Buildings A503.2, A504.1, A505.1, A506.3.2, A507.1

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A36/A36M-08 Specification for Carbon Structural Steel A405.3.3
A 653/A653M‒11 Standard Specification for Steel Sheet, Zinc Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by Hot-Dip Process
A304.2.6
B 695‒04(2009) Standard Specification for Coating of Zinc Mechanically Deposited on
Iron And Steel
A304.2.6
C 496‒96/C496M-11 Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens A104, A106.3.3.2
E 488-10 Test Method for Strength of Anchors in Concrete and Masonry Elements A107.5.3
E 519/E519M‒2010 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages A104, A106.3.3.2

ICC International Code Council
500 New Jersey Avenue, NW, 6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
BNBC‒93 BOCA National Building Code® A502
BNBC‒96 BOCA National Building Code® A502
BNBC‒99 BOCA National Building Code® A202
IBC‒00 International Building Code® A202.1, A502.1
IBC‒03 International Building Code® A202.1, A502.1
IBC‒06 International Building Code® A202.1, A502.1
IBC‒09 International Building Code® A202.1, A502.1
IBC‒12 International Building Code® A202.1, A502.1
IBC‒15 International Building Code® A102.2, A108.2, A202.1, A203, A206.3, A206.9, A403.1, A405.1, A407.1, A502.1, A503.3, A506.4,
SBC‒94 Standard Building Code® A502
SBC‒97 Standard Building Code® A502
SBC‒99 Standard Building Code® A202, A502
UBC‒76 Uniform Building Code® A502
UBC‒97 Uniform Building Code® A202, A502
Amendment Styling
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Start Free Trial
Text Size
?
Bookmarks
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Start Free Trial
History
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Start Free Trial
Bookmarks
History

Log in to your premium account or sign up to see history
Simplify coordination.

Bookmark frequently used and relevant sections to your project. Drop in comments to help expand the code and communicate with your team.

START 2 WEEK FREE TRIAL LEARN MORE

Bookmarks & comments
Project Pages
Collaborative research
Project Page exports
MULTIPLE USERS

It’s easy to get your office on board with Team licenses. Visit pricing to learn more.