ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 |
|
Standard reference number |
Title | Referenced in code section number |
A 74—06 | Specification for Cast Iron Soil Pipe and Fittings | Table 505.1 |
A 888—09 | Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application | Table 505.1 |
B 32—08 | Specification for Solder Metal | 505.8.2 |
B 75—02 | Specification for Seamless Copper Tube | Table 505.1 |
B 88—03 | Specification for Seamless Copper Water Tube | Table 505.1 |
B 251—02e01 | Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube | Table 505.1 |
B 813—00(2009) | Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper-alloy Tube | 505.8.2 |
B 828—02 | Practice for Making Capillary Joints by Soldering of Copper and Copper-alloy Tube and Fittings | 505.8.2 |
C 4—04e01 | Specification for Clay Drain Tile and Perforated Clay Drain Tile | Table 505.1 |
C 14—07 | Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe | Table 505.1 |
C 76—08a | Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe | Table 505.1 |
C 425—04 | Specification for Compression Joints for Vitrified Clay Pipe and Fittings | 505.12, 505.13 |
C 428—05(2006) | Specification for Asbestos-cement Nonpressure Sewer Pipe | Table 505.1 |
C 443—05a | Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets | 505.7, 505.13 |
C 564—07e1 | Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings | 505.6.2, 505.6.3, 505.13 |
C 700—07a | Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated | Table 505.1 |
C 913—08 | Specification for Precast Concrete Water and Wastewater Structures | 504.2 |
C 1173—08 | Specification for Flexible Transition Couplings for Underground Piping Systems | 505.3.1, 505.5.1, 505.7, 505.10.1, 505.12, 505.13 |
C 1277—08 | Specification for Shielding Coupling Joining Hubless Cast-iron Pipe and Fittings | 505.6.3 |
C 1440—08 | Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems | 505.13 |
C 1460—08 | Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground | 505.13 |
C 1461—08 | Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use | 505.13 |
D 1869—95(2005)e1 | Specification for Rubber Rings for Asbestos-cement Pipe | 505.4, 505.13 |
D 2235—04 | Specification for Solvent Cement for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe and Fittings | 505.3.2, 505.5.2 |
D 2564—04e01 | Specification for Solvent Cements for Poly Vinyl Chloride (PVC) Plastic Piping Systems | 505.10.2, 505.11.2 |
D 2657—07 | Standard Practice for Heat-fusion Joining of Polyolefin Pipe and Fittings | 505.9.1 |
D 2661—08 | Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings | Table 505.1, 505.3.2, 505.5.2 |
D 2665—09 | Specification for Poly Vinyl Chloride (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings | Table 505.1 |
D 2729—03 | Specification for Poly Vinyl Chloride (PVC) Sewer Pipe and Fittings | Table 505.1.1 |
D 2751—05 | Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and Fittings | Table 505.1 |
D 2855—96(2002) | Standard Practice for Making Solvent-cemented Joints with Poly Vinyl Chloride (PVC) Pipe and Fittings | 505.10.2, 505.11.2 |
D 2949—01a(2008) | Specification for 3.25-inch Outside Diameter Poly Vinyl Chloride (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings. | Table 505.1 |
D 3034—08 | Specification for Type PSM Poly Vinyl Chloride (PVC) Sewer Pipe and Fittings | Table 505.1 |
D 3212—07 | Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals | 505.3.1, 505.5.1, 505.10.1 |
D 4021—92 | Specification for Glass-fiber Reinforced Polyester Underground Petroleum Storage Tanks | 504.4 |
F 405—05 | Specification for Corrugated Polyethylene (PE) Pipe and Fittings | Table 505.1.1 |
F 477—08 | Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe | 505.13 |
F 628—08 | Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core | Table 505.1, 505.3.2, 505.5.2 |
F 656—08 | Specification for Primers for Use in Solvent Cement Joints of Poly Vinyl Chloride (PVC) Plastic Pipe and Fittings | 505.10.2, 505.11.2 |
F 891—04 | Specification for Coextruded Poly Vinyl Chloride (PVC) Plastic Pipe with a Cellular Core | Table 505.1 |
F 1488—03 | Specification for Coextruded Composite Pipe | Table 505.1, Table 505.1.1 |
F 1499—01(2008) | Specification for Coextruded Composite Drain Waste and Vent Pipe (DWV) | Table 505.1 |
CSA | Canadian Standards Assocation 5060 Spectrum Way Mississauga, Ontario Canada L4W 5N6 |
|
Standard reference number |
Title | Referenced in code section number |
A257.1M—92 | Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings | Table 505.1 |
A257.2M—92 | Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings | Table 505.1 |
A257.3M—92 | Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets |
505.7, 505.13 |
B137.3—05 | Rigid Poly Vinyl Chloride (PVC) Pipe for Pressure Applications | 505.10.2, 505.11.2 |
B181.1—06 | Acrylonitrile-butadiene-styrene (ABS) Drain, Waste, and Vent Pipe and Pipe Fittings | 505.3.2, 505.5.2 |
B181.2—06 | (PVC) Polyvinylchloride and Chlorinated Polyvinylchloride (CPVC) Drain, Waste,and Vent Pipe and Pipe Fittings | 505.10.2, 505.11.2 |
B182.1—06 | Plastic Drain and Sewer Pipe and Pipe Fittings | 505.10.2, 505.11.2 |
B182.2—06 | (PVC) Polyvinylchloride Sewer Pipe and Fittings PSM Type | Table 505.1 |
B182.4—06 | Profile PVC Sewer Pipe and Fittings | Table 505.1 |
B602—05 | Mechanical Couplings for Drain, Waste, and Vent Pipe and Sewer Pipe | 505.3.1, 505.5.1, 505.6.3, 505.7, 505.10.1, 505.12, 505.13 |
CISPI | Cast Iron Soil Pipe Institute 5959 Shallowford Road, Suite 419 Chattanooga, TN 37421 |
|
Standard reference number |
Title | Referenced in code section number |
301—04a | Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications | Table 505.1 |
310—04 | Specification for Coupling for Use in Connection with Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications | 505.6.3 |
ICC | International Code Council 500 New Jersey Avenue, NW, 6th Floor Washing ton, DC 20001 |
|
Standard reference number |
Title | Referenced in code section number |
IBC—12 | International Building Code® | 201.3 |
IPC—12 | International Plumbing Code® | 201.3, 505.14 |
NSF | National Sanitation Foundation 789 N. Dixboro Road P. O. Box 130140 Ann Arbor, MI 48113-0140 |
|
Standard reference number |
Title | Referenced in code section number |
40—2000 | Residential Wastewater Treatment Systems | 1102.1 |
41—1999 | Nonliquid Saturated Treatment Systems (Composing Toilets) | 1301.2 |
UL | Underwriters Laboratories Inc. 333 Pfingsten Road Northbrook, IL 60062-2096 |
|
Standard reference number |
Title | Referenced in code section number |
70—2001 | Septic Tanks, Bituminous-coated Metal | 504.3 |