CODES

ADOPTS WITHOUT AMENDMENTS:

ICC Performance Code for Buildings and Facilities 2012 (ICCPC 2012)

Copyright

Preface

Effective Use of the Icc Performance Code for Buildings and Facilities

Guide to the Use of the Icc Performance Code for Buildings and Facilities

Legislation

Chapter 1 General Administrative Provisions

Chapter 2 Definitions

Chapter 3 Design Performance Levels

Chapter 4 Reliability and Durability

Chapter 5 Stability

Chapter 6 Fire Safety

Chapter 7 Pedestrian Circulation

Chapter 8 Safety of Users

Chapter 9 Moisture

Chapter 10 Interior Environment

Chapter 11 Mechanical

Chapter 12 Plumbing

Chapter 13 Fuel Gas

Chapter 14 Electricity

Chapter 15 Energy Efficiency

Chapter 16 Fire Prevention

Chapter 17 Fire Impact Management

Chapter 18 Management of People

Chapter 19 Means of Egress

Chapter 20 Emergency Notification, Access and Facilities

Chapter 21 Emergency Responder Safety

Chapter 22 Hazardous Materials

Appendix A Risk Factors of Use and Occupancy Classifications

Appendix B Worksheet for Assigning Specific Structures to Performance Groups

Appendix C Individually Substantiated Design Method

Appendix D Qualification Characteristics for Design and Review of Performance-Based Designs

Appendix E Use of Computer Models

References

To safeguard people from injury and protect the building or other property from damage caused by surface water and to protect outfalls of drainage systems that may become contaminated from on-site hazardous material storage.
Buildings and sites shall be constructed in a way that protects people and other property from the adverse effects of surface water.
Building or building sites used for the storage or use of hazardous materials shall include provisions to ensure that hazardous materials are not accidentally transported across property lines into drainage outfalls.
Surface water shall be removed in a manner that avoids damage or nuisance to the building or other property.
Surface water or water used for fire fighting and other uses shall be routed so as not to transport hazardous material across property lines or into drainage outfalls.
Surface water drainage systems shall convey surface water runoff to an appropriate outfall.
Drainage systems shall be constructed so as to avoid the likelihood of blockage.
Drainage systems shall be constructed so as to have reasonable access for cleaning.
To safeguard people from injury and property from damage that could result from external moisture entering the building.
Buildings shall be constructed to provide adequate resistance to penetration by, and the accumulation of, moisture from the outside.
Roofs and exterior walls shall prevent the penetration of water that could cause damage to building elements.
Walls, floors and structural elements in contact with the ground shall not absorb or transmit moisture in quantities that could cause damage to building elements.
Concealed spaces and cavities in buildings shall be constructed in a way that prevents external moisture from causing degradation of building elements.
Excess moisture present at the completion of construction shall be capable of being dissipated without permanent damage to building elements.
To safeguard people against illness or injury that could result from accumulation of internal moisture, and to protect an occupancy from damage caused by free water from another occupancy in the same building.
Buildings shall be constructed to avoid the likelihood of:
1. Fungal growths or the accumulation of contaminants on linings and other building elements.
2. Free water overflow penetrating to an adjoining occupancy.
3. Damage to building elements being caused by the use of water.
An adequate means shall be provided to remove excess moisture or protect the structure from the effects of excess moisture and condensation to all habitable spaces, bathrooms, laundries and other locations where moisture may be generated.
Accidental overflow from sanitary fixtures or laundering facilities shall be constrained from penetrating another occupancy in the same building.
Floor surfaces of any space containing sanitary fixtures or laundering facilities shall be impervious to water and easily cleaned.
Wall surfaces adjacent to sanitary fixtures or laundering facilities shall be impervious to water and easily cleaned.
Surfaces of building elements likely to be splashed or to become contaminated in the course of the intended use of the building shall be impervious to water and easily cleaned.
Water splash shall be prevented from penetrating behind linings or into concealed spaces.