This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.
ANSI | American National Standards Institute 25 West 43rd Street Fourth Floor New York, NY 10036 | |
Standard reference number | Title | Referenced in code section number |
ANSI A13.1—2007 | Scheme for the Identification of Piping Systems | 704.1.2.2 |
ANSI CSA-America FC 1—03 | Stationery Fuel Cell Power Systems | 633.1 |
LC 1/CSA 6.26—05 | Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) | 403.5.4 |
ANSI LC-4—07 | Press-connect Copper and Copper Alloy Fittings for Use In Fuel Gas Distribution Systems | 403.10.2 |
Z21.1—05 | Household Cooking Gas Appliances | 623.1 |
Z21.5.1/CSA 7.1—06 | Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers | 613.1 |
Z21.5.2/CSA 7.2—05 | Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers | 613.1, 614.3 |
Z21.8—94 (R2002) | Installation of Domestic Gas Conversion Burners | 619.1 |
Z21.10.1/CSA 4.1—09 | Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings of 75,000 Btu per Hour or Less | 624.1 |
Z21.10.3/CSA 4.3—04 | Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings Above 75,000 Btu per hour, Circulating and Instantaneous | 624.1 |
Z21.11.2—07 | Gas-fired Room Heaters-Volume II-Unvented Room Heaters | 621.1 |
Z21.13/CSA 4.9—10 | Gas-fired Low-pressure Steam and Hot Water Boilers | 631.1 |
Z21.15/CGA 9.1—09 | Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves | 409.1.1 |
Z21.19/CSA 1.4—02(R2007) | Refrigerators Using Gas (R1999) Fuel | 625.1 |
Z21.24/CGA 6.10—06 | Connectors for Gas Appliances | 411.1 |
Z21.40.1/CGA 2.91—96 (R2002) | Gas-Fired Heat Activated Air Conditioning and Heat Pump Appliances | 627.1 |
Z21.40.2/CGA 2.92—96 (R2002) | Gas-Fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion) | 627.1 |
Z21.42—93 (R2002) | Gas-Fired Illuminating Appliances | 628.1 |
Z21.47/CSA 2.3—06 | Gas-Fired Central Furnaces | 618.1 |
Z21.50/CSA 2.22—07 | Vented Gas Fireplaces | 604.1 |
Z21.56/CSA 4.7—06 | Gas-Fired Pool Heaters | 617.1 |
Z21.58/CSA 1.6—07 | Outdoor Cooking Gas Appliances | 623.1 |
Z21.60/CSA 2.26—03 | Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces | 602.1 |
Z21.61—83 (R2004) | Gas-fired Toilets | 626.1 |
Z21.69/CSA 6.16—09 | Connectors for Movable Gas Appliances | 411.1.1 |
Z21.75/CSA 6.27—07 | Connectors for Outdoor Gas Appliances and Manufactured Homes | 411.1, 411.2 |
Z21.80—03(R2008) | Line Pressure Regulators | 410.1 |
Z21.84—02 | Manually-lighted, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces—with Addenda Z21.84a-2003 | 602.1, 602.2 |
Z21.86—08 | Vented Gas-fired Space Heating Appliances | 608.1, 609.1, 622.1 |
Z21.88/CSA 2.33—09 | Vented Gas Fireplace Heaters | 605.1 |
Z21.91—07 | Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters | 621.7.1 |
Z21.97—09 | Outdoor Decorative Appliances | 636 |
Z83.4/CSA 3.7—03 | Nonrecirculating Direct-gas-fired Industrial Air Heaters | 611.1 |
Z83.6—90 (R1998) | Gas-fired Infrared Heaters | 630.1 |
Z83.8/CSA 2.6—09 | Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces | 620.1 |
Z83.11/CSA 1.8—06 | Gas Food Service Equipment | 623.1 |
Z83.18—04 | Recirculating Direct Gas-fired Industrial Air Heaters | 612.1 |
Z83.19—01(R2005) | Gas-fired High-intensity Infrared Heaters | 630.1 |
Z83.20—08 | Gas-fired Low-intensity Infrared Heaters | 630.1 |
ASME | American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 | |
Standard reference number | Title | Referenced in code section number |
B1.20.1—83 (Reaffirmed 2006) | Pipe Threads, General Purpose (inch) | 403.9 |
B16.1—2005 (Reaffirmed 2004) | Cast-iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250 | 403.12 |
B16.20—98 (Reaffirmed 2007) | Metallic Gaskets for Pipe Flanges Ring-joint, Spiral-wound and Jacketed | 403.12 |
B16.33—02 (Reaffirmed 2007) | Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2) | 409.1.1 |
B16.44—2002 (Reaffirmed 2007) | Manually Operated Metallic Gas Valves for Use in Aboveground Piping Systems Up to 5 psi | 409.1.1 |
B31.3—04 | Process Piping | 704.1.2, 704.1.2.4, 705.2, 705.3 |
B36.10M—2004 | Welded and Seamless Wrought-steel Pipe | 403.4.2 |
BPVC—07 | ASME Boiler & Pressure Vessel Code (2007 Edition). | 631.1, 703.2.2, 703.3.3, 703.3.4 |
CSD-1—2009 | Controls and Safety Devices for Automatically Fired Boilers | 631.1 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | |
Standard reference number | Title | Referenced in code section number |
A 53/A 53M—07 | Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless | 403.4.2 |
A 106/A 106M—08 | Specification for Seamless Carbon Steel Pipe for High-temperature Service | 403.4.2 |
A 254—97 (2007) | Specification for Copper Brazed Steel Tubing | 403.5.1 |
B 88—03 | Specification for Seamless Copper Water Tube | 403.5.2 |
B 210—04 | Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes | 403.5.3 |
B 241/B 241M—02 | Specification for Aluminum and Aluminum-alloy, Seamless Pipe and Seamless Extruded Tube | 403.4.4, 403.5.3 |
C 315—07 | Specification for Clay Flue Liners and Chimney Pots | 501.12 |
D 2513—09 | Specification for Polyethylene (PE) Gas Pressure Pipe, Tubing and Fittings | 403.6, 403.6.1, 403.11, 404.17.2 |
D 2513—08b | Specification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings | 403.6 |
F 1973—08 | Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11) and Polyamide 12 (PA12) Fuel Gas Distribution Systems | 404.17.2 |
CGA | Compressed Gas Association 1725 Jefferson Davis High way, 5th Floor Arlington, VA 22202-4102 | |
Standard reference number | Title | Referenced in code section number |
S-1.1—(2002) | Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases | 703.3 |
S-1.2—(1995) | Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases | 703.3 |
S-1.3—(1995) | Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases | 703.3 |
CSA | CSA America Inc. 8501 E. Pleasant Valley Rd. Cleveland, OH USA 44131-5575 | |
Standard reference number | Title | Referenced in code section number |
ANSI CSA America FC1—03 | Stationary Fuel Cell Power Systems | 633.1 |
CSA 8—93 | Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces—with Revisions through January 1999 | 603.1 |
DOTn | Department of Transportation 400 Seventh St. SW. Washington, DC 20590 | |
Standard reference number | Title | Referenced in code section number |
49 CFR, Parts 192.281(e) & 192.283 (b)—(2009) | Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards | 403.6.1 |
49 CFR Parts 100—180 | Hazardous Materials Regulations | 703.2.2, 703.3.3, 703.3.4 |
ICC | International Code Council, Inc. 500 New Jersey Ave, NW 6th Floor Washington, DC 20001 | |
Standard reference number | Title | Referenced in code section number |
IBC—12 | International Building Code® | 102.2.1,201.3,301.10,301.11,301.12,301.14,302.1,302.2,305.6,306.6,401.1.1,412.6,413.3,413.3.1,501.1,501.3,501.12,501.15.4,609.3,614.2,706.2,706.3 |
IECC—12 | International Energy Conservation Code® | 301.2 |
IFC—12 | International Fire Code® | 201.3,401.2,412.1,412.6,412.7,412.7.3,412.8,413.1,413.3,413.3.1,413.5,413.9.2.5,701.1,701.2,703.2,703.2.2,703.3.8,703.4,703.5,704.1.2,704.3,704.4,706.2,706.3,707.1,707.2,708.1 |
IMC—12 | International Mechanical Code® | 101.2.5,201.3,301.1.1,301.13,304.11,501.1,614.2,618.5,621.1,624.1,631.2,632.1,703.1.2 |
IPC—12 | International Plumbing Code® | 201.3,301.6,624.1.1,624.2 |
IRC—12 | International Residential Code® | 703.2.1 |
MSS | Manufacturers Standardization Society of the Valve and Fittings Industry 127 Park Street, Northeast Vienna, VA 22180 | |
Standard reference number | Title | Referenced in code section number |
SP-6—01 | Standard Finishes for Contact Faces of Pipe Flanges and Connecting-end Flanges of Valves and Fittings | 403.12 |
SP-58—93 | Pipe Hangers and Supports—Materials, Design and Manufacture | 407.2 |
NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101 | |
Standard reference number | Title | Referenced in code section number |
30A—12 | Code for Motor Fuel Dispensing Facilities and Repair Garages | 305.4 |
37—10 | Installation and Use of Stationary Combustion Engines and Gas Turbines | 616.1 |
51—02 | Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes | 414.1 |
58—11 | Liquefied Petroleum Gas Code | 401.2, 402.6, 403.11 |
70—11 | National Electrical Code | 306.3.1, 306.4.1, 306.5.2, 309.2, 413.9.2.4, 703.6 |
82—09 | Incinerators, Waste and Linen Handling Systems and Equipment | 503.2.5, 607.1 |
85—11 | Boiler and Combustion Systems Hazards Code | 631.1 |
88A—11 | Parking Structures | 305.9 |
211—10 | Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances | 503.5.2, 503.5.3, 503.5.6.1, 503.5.6.3 |
409—10 | Aircraft Hangars | 305.11 |
853—10 | Installation of Stationary Fuel Cell Power Systems | 633.1 |
UL | Underwriters Laboratories Inc. 333 Pfingsten Road Northbrook, IL 60062 | |
Standard reference number | Title | Referenced in code section number |
103—2001 | Factory-built Chimneys, Residential Type and Building Heating Appliances—with Revisions through March 2010 | 506.1 |
127—08 | Factory-built Fireplaces—with Revisions through January 2010 | 621.7 |
441—2010 | Gas Vents—with Revisions through August 2006 | 502.1 |
641—95 | Type L Low-temperature Venting Systems—with Revisions through July 2009 | 502.1 |
651—05 | Schedule 40 and 80 Rigid PVC Conduit and Fittings—with Revisions through March 2010 | 403.6.3 |
795—2006 | Commercial-industrial Gas Heating Equipment—with Revisions through April 2010 | 610.1, 618.1, 631.1 |
959—01 | Medium Heat Appliance Factory-built Chimneys—with Revisions through June 2010 | 506.3 |
1738—1993 | Venting Systems for Gas Burning Appliances, Categories II, III and IV—with Revisions through October 2006 | 502.1 |
1777—2007 | Chimney Liners—with Revisions through July 2009 | 501.12, 501.15.4 |
2200—98 | Stationary Engine Generator Assemblies—with Revisions through December 2009 | 616.1 |