About this chapter: The one- and two-family dwelling code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials, products and methods of construction. Chapter 44 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.
AAMA
American Architectural Manufacturers Association
1900 E. Golf Road, Suite 1250
Schaumburg, IL 60173506—16
Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products
711—20
Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products
714—19
Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standards/Specifications for Windows, Doors and Skylights
ACCA
Air Conditioning Contractors of America
1330 Braddock Place, Suite 350
Alexandria, VA 22314ACI
318—19
Building Code Requirements for Structural Concrete
332—20
Residential Code Requirements for Structural Concrete
AISI
American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington, DC 20001AISI S100—16 (2020) w/S2—20
North American Specification for the Design of Cold-Formed Steel Structural Members, 2016 Edition (Reaffirmed 2020), with Supplement 2, 2020 Edition
AISI S230—19
Standard for Cold-Formed Steel Framing—Prescriptive Method for One- and Two-Family Dwellings, 2019 Edition
R301.1.1, R301.2.1.1, R301.2.2.7, R301.2.2.8, R603.6, R603.9.4.1, R603.9.4.2, Figure 608.9(11), R608.9.2, R608.9.3, R608.10
AMCA
Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004ANSI/AMCA 210-ANSI/ASHRAE 51—16
Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
Table M1504.2, M1505.3
ANSI
A108.1B—2017
Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
A108.4—09
Installation of Ceramic Tile with Organic Adhesives or Water-Cleanable Tile-setting Epoxy Adhesive
A108.5—20
Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex Portland Cement Mortar
A108.6—99(reaffirmed 2019)
Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy
A118.3—13
American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy, and Water-cleanable Tile-setting Epoxy Adhesive
A118.10—14
Specification for Load-bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation
A136.1—20
American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile
ANSI 117—2020
Standard Specifications for Structural Glued Laminated Timber of Softwood Species
ANSI/CSA FC 1—2014
Fuel Cell Technologies—Part 3-100: Stationary Fuel Cell Power Systems—Safety
LC1/CSA 6.26—2018
Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)
LC4/CSA 6.32—12
Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems
Z21.10.1/CSA 4.1—2017
Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings of 75,000 Btu per hour or Less
Z21.10.3/CSA 4.3—2017
Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings above 75,000 Btu per hour, Circulating and Instantaneous
Z21.15/CSA 9.1—09(R2014)
Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves
Table G2420.1.1
Z21.40.1/CSA 2.91—96(R2017)
Gas-fired, Heat-activated Air-conditioning and Heat Pump Appliances
Z21.40.2/CSA 2.92—96(R2017)
Gas-fired Work Activated Air-conditioning and Heat Pump Appliances (Internal Combustion)
Z21.60/CSA 2.26—2017
Z21.84—2017
Manually Lighted, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel-burning Appliances
Z21.93/CSA 6.30—2017
Excess Flow Valves for Natural Gas and Propane Gas with Pressures up to 5 psig
Z83.8/CSA 2.6—2016
Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters, and Gas-fired Duct Furnaces
APA
APA—The Engineered Wood Association
7011 South 19th Street
Tacoma, WA 98466ANSI/APA PRG 320—2019
Standard for Performance-rated Cross Laminated Timber
ANSI/APA PRP 210—2019
Standard for Performance-rated Engineered Wood Siding
ANSI/APA PRR 410—2016
Standard for Performance-rated Engineered Wood Rim Boards
ANSI/APA PRS 610.1—2018
Standard for Performance-Rated Structural Insulated Panels in Wall Applications
APSP
Pool & Hot Tub Alliance (formerly the Association of Pool & Spa Professionals)
211 Eisenhower Avenue, Suite 500
Alexander, VA 22314ANSI/APSP/ICC 14—2019
American National Standard for Portable Electric Spa Energy Efficiency
N1103.11
ANSI/APSP/ICC 15a—2011
American National Standard for Residential Swimming Pool and Spas—Includes Addenda A Approved January 9, 2013
N1103.12
ASCE/SEI
American Society of Civil Engineers
Structural Engineering Institute
Reston, VA 20191-44007—16 with Supplement 1
Minimum Design Loads and Associated Criteria for Buildings and Other Structures
24—14
Flood-resistant Design and Construction
ASHRAE
ASHRAE
180 Technology Parkway NW
Peachtree Corners, GA 30092ASHRAE—2001
2001 ASHRAE Handbook of Fundamentals
Table N1105.4.2(1)
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York, NY 10016-5990A112.1.2—2012(R2017)
A112.1.3—2000 (R2019)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances
A112.3.1—2007(R2017)
Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground
A112.3.4—2018/CSA B45.9—2018
Macerating Toilet Systems and Related Components
Table P2701.1, P3007.5
A112.4.3—1999(R2019)
Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System
A112.6.2—2017
Table P2701.1, P2702.4
A112.18.1—2018/CSA B125.1—2018
A112.18.3M—2002(R2017)
Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings
A112.19.1—2018/CSA B45.2—18
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
Table P2701.1, P2711.1
A112.19.2—2018/CSA B45.1—18
Ceramic Plumbing Fixtures
A112.19.3—2017/CSA B45.4—2017
Stainless Steel Plumbing Fixtures
A112.19.5—2017/CSA B45.15—2017
Flush Valves and Spuds for Water-closets, Urinals and Tanks
Table P2701.1
A112.19.7—2012/CSA B45.10—2012(R2017)
Hydromassage Bathtub Systems
Table P2701.1
A112.19.12—2014(R2019)
ASSE 1002—2020/ASME A112.1002—2020/CSA B125.12—20
Anti-Siphon Fill Valves
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1070—2020/ASME A112.1070—2020
Performance Requirements for Water-temperature-limiting Devices
B1.20.1—2013(R2018)
Pipe Threads, General-purpose (Inch)
B16.3—2016
Malleable-iron-threaded Fittings, 150 and 300
Table P2906.6
B16.4—2016
Gray-iron-threaded Fittings
Table P2906.6, Table P3002.3
B16.9—2018
Factory-made, Wrought-steel Buttwelding Fittings
Table P2906.6
B16.11—2016
Forged Fittings, Socket-welding and Threaded
Table P2906.6
B16.15—2018
Cast Alloy Threaded Fittings: Classes 125 and 250
Table P2906.6, Table P3002.3
B16.18—2018
Cast-copper-alloy Solder Joint Pressure Fittings
Table P2906.6, Table P3002.3
B16.22—2018
Wrought-copper and Copper-alloy Solder Joint Pressure Fittings
Table P2906.6, Table P3002.3
B16.26—2018
Cast-copper-alloy Fittings for Flared Copper Tubes
Table P2906.6, Table P3002.3
B16.29—2017
Wrought-copper and Wrought-copper-alloy Solder Joint Drainage Fittings (DWV)
Table P3002.3
B16.33—2012(R2017)
Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)
Table G2420.1.1
B16.34—2017
Valves—Flanged, Threaded and Welding End
Table P2903.9.4
B16.44—2012(R2017)
Manually Operated Metallic Gas Valves for Use in Above-ground Piping Systems up to 5 psi
Table G2420.1.1
B16.51—2018
Copper and Copper Alloy Press-Connect Pressure Fittings
BPVC—2019
ASME Boiler and Pressure Vessel Code (Sections I, II, IV, V, VI and VIII)
ASSE
ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena, IL 604481003—2009
Performance Requirements for Water-pressure-reducing Valves for Domestic Water Distribution Systems
1008—2006
Table P2701.1
1012—2009
Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent
1013—2011
Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers
1015—2011
Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
Table P2902.3, P2902.3.6
1017—2009
Performance Requirements for Temperature-actuated Mixing Valves for Hot Water Distribution Systems
1018—2001
Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied
1019—2011(R2016)
Performance Requirements for Freeze-resistant, Wall Hydrants, Vacuum Breaker, Draining Types
1023—1979
Performance Requirements for Hot Water Dispensers, Household-storage-type—Electrical
Table P2701.1
1024—2017
Performance Requirements for Dual Check Backflow Preventers, Anti-siphon-type, Residential Applications
Table P2902.3, P2902.3.7
1035—2008
Performance Requirements for Laboratory Faucet Backflow Preventers
Table P2902.3, P2902.3.2
1044—2015
Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types
1047—2011
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
Table P2902.3, P2902.3.5
1048—2011
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
Table P2902.3, P2902.3.6
1050—2009
Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
1051—2009
Performance Requirements for Individual and Branch-type Air Admittance Valves for Plumbing Drainage Systems
1052—2016
Performance Requirements for Hose Connection Backflow Preventers
1062—2017
Performance Requirements for Temperature-actuated, Flow Reduction (TAFR) Valves for Individual Supply Fittings
Table P2701.1, P2724.2
1066—1997
Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings
1072—2007
Performance Requirements for Barrier-type Floor Drain Trap Seal Protection Devices
1081—2014
Performance Requirements for Backflow Preventers with Integral Pressure Reducing Boiler Feed Valve and Intermediate Atmospheric Vent Style for Domestic and Light Commercial Water Distribution Systems
Table P2902.3, P2902.3.3
ASSE 1002—2020/ASME A112.1002—2020/CSA B125.12—20
Anti-Siphon Fill Valves
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures
Table P2701.1
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken, PA 19428A53/A53M—2018
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless
A74—2017
Specification for Cast-iron Soil Pipe and Fittings
A106/A106M—2018
Specification for Seamless Carbon Steel Pipe for High-temperature Service
Table M2101.1, G2414.4.2
A123/A123M—2017
Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
Table 507.2.3
A126—04(2014)
Gray Iron Castings for Valves, Flanges and Pipe Fittings
Table P2903.9.4
A153/A153M—2016A
Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware
A167—99(2009)
Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip
Table R606.3.4.1
A240/A240M—17
Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
Table R905.10.3(1)
A268/A268M—2010(16)
Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service
A269/A269M—2015A
Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service
A307—2014E1
Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength
Table R507.2.3, R608.5.2.2
A312—2018
Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes
A463/A463M—15
Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process
Table R905.10.3(2)
A539—99
Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines
A563—15
Standard Specification for Carbon and Alloy Steel Nuts
Table R507.2.3
A615/A615M—2015aE1
Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement
A641/A641M—09a(2014)
Specification for Zinc-coated (Galvanized) Carbon Steel Wire
Table R606.3.4.1
A653—2017
Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated (Galvannealed) by the Hot-dip Process
A706M—2016
Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A755M—2016E1
Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products
Table R905.10.3(2)
A778M—2016
Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products
Table P2906.4, Table P2906.5, Table P2906.6
A792/A792M—10(2015)
Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process
A875/A875M—13
Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process
R608.5.2.3, Table R905.10.3(2)
A888—2018
A924M—2017A
Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process
Table R905.10.3(1)
A996M—2016
Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement
A1003/A1003M—15
Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members
B42—2015A
Specification for Seamless Copper Pipe, Standard Sizes
Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)
B43—15
Specification for Seamless Red Brass Pipe, Standard Sizes
Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)
B75/B75M—11
Specification for Seamless Copper Tube
B88—2016
Specification for Seamless Copper Water Tube
Table M2101.1, G2414.5.2, Table P2906.4, Table P2906.5, Table P3002.1(1), Table P3002.1(2), Table P3002.2
B101—12
Specification for Lead-coated Copper Sheet and Strip for Building Construction
Table R905.2.8.2, Table R905.10.3(1)
B135M—2017
Specification for Seamless Brass Tube
Table M2101.1
B209—14
Specification for Aluminum and Aluminum-alloy Sheet and Plate
Table 905.10.3(1)
B251/B251M—2017
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B280—13
Standard Specification for Seamless Copper Tube for Air-Conditioning and Refrigeration Field Service
B302—2017
Specification for Threadless Copper Pipe, Standard Sizes
Table M2101.1, Table P2906.4, Table P2906.5, Table P3002.1(1)
B306—13
Specification for Copper Drainage Tube (DWV)
B370—12
Specification for Copper Sheet and Strip for Building Construction
B447—12a
Specification for Welded Copper Tube
Table P2906.4, Table P2906.5
B695—2004(2016)
Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel
B813—2016
Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube
B828—2016
Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings
C27—1998(2018)
Specification for Standard Classification of Fireclay and High-alumina Refractory Brick
C62—2017
Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)
C73—2017
Specification for Calcium Silicate Face Brick (Sand Lime Brick)
C126—2017
Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units
C207—2018
Specification for Hydrated Lime for Masonry Purposes
Table R606.2.8
C208—2012(2017)E1
Specification for Cellulosic Fiber Insulating Board
C216—2017A
C315—2007(2016)
C425—2004(2018)
Specification for Compression Joints for Vitrified Clay Pipe and Fittings
C443—2012(2017)
Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets
C557—2003(2017)
Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing
C564—14
Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings
C578—2018
Specification for Rigid, Cellular Polystyrene Thermal Insulation
C652—2017A
C685/C685M—2017
Specification for Concrete Made by Volumetric Batching and Continuous Mixing
C700—2018
Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated
Table P3002.2, Table P3002.3, Table P3302.1
C726—2017
Standard Specification for Mineral Wool Roof Insulation Board
Table R906.2
C728—2017A
Standard Specification for Perlite Thermal Insulation Board
Table R906.2
C836/C836M—2018
Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course
C887—13
Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar
C926—2018B
Specification for Application of Portland Cement-based Plaster
C954—2018
Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness
C957/C957M—2017
Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Integral Wearing Surface
C1002—2018
Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
C1047—14a
Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
C1063—2018B
Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster
C1107/C1107M—2017
Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)
C1173—2018
Specification for Flexible Transition Couplings for Underground Piping Systems
C1177/C1177M—2017
Specification for Glass Mat Gypsum Substrate for Use as Sheathing
R702.3.1, Table 906.2
C1178/C1178M—2018
Specification for Glass Mat Water-resistant Gypsum Backing Panel
C1277—2018
Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings
C1278/C1278M—2017
Specification for Fiber-reinforced Gypsum Panels
C1280—13a
Standard Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing
Table R602.3(1)
C1288—2017
Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets
C1289—2018
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
C1325—2018
Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets Backer Units
Table R702.4.2
C1363—11
The Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
N1101.10.4.1
C1396/C1396M—2017
Specification for Gypsum Board
C1440—2017
Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
C1460—2017
Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground
C1461—2008(2017)
Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use
C1513—2018
Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections
C1540—2018
Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings
C1668—13a
Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating, Ventilation, and Air Conditioning (HVAC) Systems
C1670/1670M—2018
Standard Specification for Adhered Manufactured Stone Masonry Veneer Units
C1691—2011(2017)
Standard Specification for Unreinforced Autoclaved Aerated Concrete (AAC) Masonry Units
D41/D41M—2011(2016)
Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing
Table R905.9.2, Table R905.11.2
D43/D43M—2000(20118)
Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
Table R905.9.2
D226/D226M—2017
Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing
D227/D227M—2003(2018)
Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing
Table R905.9.2
D312/D312M—2016M
Specification for Asphalt Used in Roofing
Table R905.9.2
D450/D450M—2017(2018)
Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing
Table R905.9.2
D1227—13
Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
D1527—99(2005)
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe, Schedules 40 and 80
Table P2906.4
D1693—15
Test Method for Environmental Stress-cracking of Ethylene Plastics
Table M2101.1
D1784—11
Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
D1785—15E1
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
Table P2906.4
D1863/D1863M—2005(2018)
Specification for Mineral Aggregate Used in Built-up Roofs
Table R905.9.2
D1970/D1970M—2017A
Specification for Self-adhering Polymer Modified Bitumen Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection
D2104—03
Specification for Polyethylene (PE) Plastic Pipe, Schedule 40
Table P2906.4
D2178/D2178M—15A
Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
Table R905.9.2
D2235—2004(2016)
Specification for Solvent Cement for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe and Fittings
D2239—12A
Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter
Table P2906.4
D2241—15
Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)
Table P2906.4
D2282—99(2005)
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR)
Table P2906.4
D2412—2011(2018)
Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading
D2447—03
Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on Outside Diameter
Table M2101.1
D2464—15
Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Table P2906.6
D2466—2017
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
Table P2906.6
D2467—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Table P2906.6
D2468—96a
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe Fittings, Schedule 40
Table P2906.6
D2513—2018A
Specification for Gas Pressure Pipe, Tubing and Fittings
D2564—2012(2018)
Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems
D2609—15
Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe
Table P2906.6
D2626/D2626M—04 (2012)e1
Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing
Table R905.1.1(1), Table R905.9.2
D2657—2007(2015)
Standard Practice for Heat Fusion-joining of Polyolefin Pipe Fittings
D2661—14E1
D2665—14
D2672—14
Specification for Joints for IPS PVC Pipe Using Solvent Cement
Table P2906.4
D2680—01(2014)
Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Composite Sewer Piping
Table P3002.2
D2683—14
Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
D2729—2017
Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
P3009.11, Table P3302.1
D2737—2012A
Specification for Polyethylene (PE) Plastic Tubing
Table P2906.4
D2751—05
Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and Fittings
Table P3002.2, Table P3002.3
D2822/D2822M—2005(2011)
Specification for Asphalt Roof Cement, Asbestos Containing
Table R905.9.2
D2824/D2824M—2018
Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos
Table R905.9.2, Table R905.11.2
D2846/D2846M—2017BE1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems
D2855—2015
Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings
D2898—2010(2017)
Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing
D2949—10
D3019/D3019—2017
Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered
Table R905.9.2, Table R905.11.2
D3034—2016
Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
Table P3002.2, Table P3002.3
D3035—15
Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter
Table M2105.4
D3138—04(2016)
Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-Pressure Piping Components
D3161/D3161M—2016A
Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan Induced Method)
D3201/D3201M—2013
Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products
D3212—07(2013)
Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
D3261—2016
Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing
D3309—96a(2002)
Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution System
Table M2101.1
D3350—14
Specification for Polyethylene Plastic Pipe and Fitting Materials
Table M2101.1
D3462/D3462M—2016
Specification for Asphalt Shingles Made from Glass Felt and Surfaced with Mineral Granules
D3468/D3468M—99(2013)E1
Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing
D3737—2018E1
Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)
D3747—79(2007)
Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation
Table R905.9.2, Table R905.11.2
D3909/D3909M—14
Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules
D4022/D4022M—2007(2012)e1
Specification for Coal Tar Roof Cement, Asbestos Containing
Table R905.9.2
D4068—2017
Specification for Chlorinated Polyethylene (CPE) Sheeting for Concealed Water Containment Membrane
D4551—2017
Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane
D4586/D4586M—2007(2018)
Specification for Asphalt Roof Cement—asbestos-free
Table R905.9.2
D4601/D4601M—04(2012)e1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
Table R905.9.2, R905.11.2.1
D4869/D4869M—2016A
Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing
D4897/D4897M—2016
Table R905.9.2
D4990—1997a(2013)
Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
Table R905.9.2
D5019—07a
Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane
D5055—2016
Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists
D5456—2018
Standard Specification for Evaluation of Structural Composite Lumber Products
D5516—2018
Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures
D5643/D5643M—2006(2018)
Specification for Coal Tar Roof Cement Asbestos-free
Table R905.9.2
D5664—2017
Test Methods for Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber
D5665/D5665M—99a(2014)E1
Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing
Table R905.9.2
D5726—98(2013)
Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing
Table R905.9.2
D6083/D6083M—2018
Specification for Liquid-applied Acrylic Coating Used in Roofing
D6162/D6162M—2016
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
Table R905.11.2
D6163/D6163M—2016
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements
Table R905.11.2
D6164/D6164M—2016
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D6222/D6222M—2016
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D6223/D6223M—2016
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement
Table R905.11.2
D6298—2016
Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface
Table R905.11.2
D6305—08(2015)E1
Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing
D6380/D6380—2003(2018)
Standard Specification for Asphalt Roll Roofing (Organic Felt)
D6464—2003A(2017)
Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing
D6694/D6694M—2015
Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems
Table R905.14.3, R905.15.2
D6757/D6757M—2018
Specification for Underlayment Felt Containing Inorganic Fibers Used with Steep Slope Roofing
D6841—2016
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber
D6947/D6947M—2016
Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System
Table R905.14.3, R905.15.2
D7032—2017
Standard Specification for Establishing Performance Ratings for Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails)
D7158—D7158M—2019
Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
R905.2.4.1, Table R905.2.4.1
D7425/D7425M—13
Standard Specification for Spray Polyurethane Foam Used for Roofing Application
D7672—2014E1
Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies
E84—2018B
Standard Test Method for Surface Burning Characteristics of Building Materials
E96/E96M—2016
Test Method for Water Vapor Transmission of Materials
E119—2018B
Test Methods for Fire Tests of Building Construction and Materials
E136—2019
Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750°C
R202, R302.11
E283—2004(2012)
Test Method for Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences across the Specimen
R202, N1102.4.5
E330/E330M—14
Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference
E331—2000(2016)
E779—2010(2018)
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
N1102.4.1.2
E970—2017
Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
E1554/E1554M—13(2018)
Standard Test Methods for Determining Air Leakage of Air Distribution Systems by Fan Pressurization
N1103.3.5
E1745—17
Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs
E1827—2011(2017)
Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door
N1102.4.1.2
E1886—2013A
Test Method for Performance Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
E1996—2017
Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
E2178—2013
Standard Test Method for Air Permeance of Building Materials
R202
E2231—2018
Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics
E2273—2018
Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies
E2556/E2556M—2010(2016)
Standard Specification for Vapor Permeable Flexible Sheet Water-Resistive Barriers Intended for Mechanical Attachment
E2570/E2570M—07(2014)E1
Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
E2634—2018
Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems
E2925—17
Standard Specification for Manufactured Polymeric Drainage and Ventilation Materials Used to Provide a Rainscreen Function
F405—05
Specification for Corrugated Polyethylene (PE) Pipe and Fittings
Table P3009.11, Table P3302.1
F409—2017
Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings
F437—15
Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
Table P2906.6
F438—2017
Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
Table P2906.6
F439—13
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
Table P2906.6
F441/F441M—15
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80
Table P2906.4, Table P2906.5
F442/F442M—13E1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)
Table P2906.4, Table P2906.5
F493—14
Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
F628—2012E2
F656—2015
Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings
F714—13
Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F844—07a(2013)
Standard Specification for Washers, Steel, Plain (Flat), Unhardened for General Use
Table R507.2.3
F876—2017
Specification for Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2906.4, Table P2906.5
F877—2018A
Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems
Table M2101.1, Table P2906.6
F891—2016
Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core
F1055—2016A
Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing
F1281—2017
Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe
Table M2101.1, P2506.12.1, Table P2906.4, Table P2906.5, Table P2906.6
F1282—2017
Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
F1412—2016
Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage
F1488—14E1
Specification for Coextruded Composite Pipe
F1504—2014
Standard Specification for Folded Poly (Vinyl Chloride) (PVC) for Existing Sewer and Conduit Rehabilitation
F1667—2018
Specification for Driven Fasteners, Nails, Spikes and Staples
F1807—2018
Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
Table M2101.1, Table P2906.6
F1866—2018
Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
Table P3002.3
F1871—2011
Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
F1924—12
Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing
F1960—2018
Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
Table M2101.1, Table P2906.6
F1970—12E1
Standard Specification for Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
M2105.5, Table 2903.9.4
F1973—2013(2018)
Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems
F1974—09(2015)
Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
Table P2906.6, P2906.12.1
F1986—2001(2011)
Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water Systems
Table P2906.4, Table P2906.5, Table P2906.6
F2080—2016
Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe
Table P2906.6
F2090—17
Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
F2098—2015
Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings
Table M2101.1, Table P2906.6
F2159—2018
Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
Table P2906.6
F2262—09
Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9
Table P2906.4, Table P2906.5
F2389—2017A
Standard for Pressure-rated Polypropylene (PP) Piping Systems
F2434—14
Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing
Table P2906.6
F2623—14
Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing
Table M2101.1
F2735—2009(2016)
Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
Table M2101.1, Table P2906.6
F2769—2018
Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution Systems
Table M2101.1, Table P2906.4, Table P2906.5, Table P2906.6
F2806—10(2015)
Standard Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (Metric SDR-PR)
Table M2101.1
F2855—12
Standard Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC AL CPVC) Composite Pressure Tubing
Table P2906.4, Table P2906.5
F2969—12
Standard Specification for Acrylonitrile-butadiene-styrene (ABS) IPS Dimensioned Pressure Pipe
Table M2101.1
F3226/F3226M—16
Standard Specification for Metallic Press-Connect Fittings for Piping and Tubing Systems
Table P2906.6
F3253—2017
Standard Specification for Crosslinked Polyethylene (PEX) Tubing with Oxygen Barrier for Hot- and Cold-Water Hydronic Distribution Systems
Table M2101.1
AWC
American Wood Council
222 Catoctin Circle SE, Suite 201
Leesburg, VA 20175ANSI/AWC NDS—2018
National Design Specification (NDS) for Wood Construction—with 2018 Supplement
ANSI/AWC WFCM—2018
Wood Frame Construction Manual for One- and Two-family Dwellings
AWPA
American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784AWS
American Welding Society
8669 NW 36 Street, #130
Miami, FL 33166AWWA
American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235C115/A21.15—11
Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
Table P2906.4
C151/A21.51—17
Ductile-iron Pipe, Centrifugally Cast, for Water
Table P2906.4
C153/A21.53—11
Ductile-iron Compact Fittings for Water Service
Table P2906.6
C500—09
Standard for Metal-seated Gate Valves for Water Supply Service
Table P2903.9.4
C504—15
Standard for Rubber-seated Butterfly Valves
Table P2903.9.4
C901—16
Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm) through 3 in. (76 mm) for Water Service
C903—16
Polyethylene-aluminum-polyethylene (PE-AL-PE) Composite Pressure Pipe, 12 mm (1/2 in.) through 50 mm (2 in.), for Water Service
Table M2105.4
C904—16
Cross-linked Polyethylene (PEX) Pressure Tubing, 1/2 in. (13 mm) through 3 in. (76 mm) for Water Service
CEN
European Committee for Standardization (EN)
Rue de la Science 23
Brussels, Belgium B - 1040EN 15250—2007
Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods
CISPI
Cast Iron Soil Pipe Institute
2401 Fieldcrest Drive
Mundelein, IL 60060CPA
Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176CPSC
Consumer Product Safety Commission
4330 East-West Highway
Bethesda, MD 2081416 CFR, Part 1201—(2002)
Safety Standard for Architectural Glazing
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516A112.19.5—2017/CSA B45.15—2017
Flush Valves and Spuds for Water-closets, Urinals and Tanks
Table P2701.1
A112.19.7—2012/CSA B45.10—2012(R2017)
Hydromassage Bathtub Systems
Table P2701.1
A257.2—14
Table P3002.2, P3003.13
A257.3—14
Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights
ANSI/CSA FC I—2014
Fuel Cell Technologies—Part 3-100; Stationary fuel cell power systems—Safety
ANSI/CSA/IGSHPA C448 Series—16
Design and Installation of Ground Source Heat Pump Systems for Commercial and Residential Buildings
Table M2105.4, Table M2105.5
ASME A112.3.4—2018/CSA B45.9—2018
Macerating Toilet Systems and Related Components
Table P2701.1, P3007.5
ASME A112.18.1—2018/CSA B125.1—2018
ASME A112.19.1—2018/CSA B45.2—18
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
Table P2701.1, P2711.1
ASME A112.19.2—2018/CSA B45.1—18
Ceramic Plumbing Fixtures
ASME A112.19.3—2017/CSA B45.4—2017
Stainless Steel Plumbing Fixtures
ASSE 1002—2020/ASME A112.1002—2020/CSA B125.12—20
Anti-Siphon Fill Valves for Water Closet Tanks
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1070—2020/ASME A112.1070—2020/CSA B125.70—2020
Performance Requirements for Water-temperature-limiting Devices
B55.1—2015
Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units
N1103.5.4
B64.2.1—11(R2016)
Hose Connection Vacuum Breakers (HCVB) with Manual Draining Feature
Table P2902.3, P2902.3.2
B64.2.2—11(2016)
Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature
Table P2902.3, P2902.3.2
B64.3—11(2016)
Dual Check Backflow Preventers with Atmospheric Port (DCAP)
B64.5.1—11(2016)
Double Check Valve Backflow Preventers, Type for Fire Systems (DCVAF)
Table P2902.3, P2902.3.6
B125.3—18
Plumbing Fittings
B137.1—17
Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services
Table P2906.4, Table P2906.6
B137.2—17
Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications
Table P2906.6
B137.3—17
Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
B137.5—17
Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
Table P2906.4, Table P2906.5, Table P2906.6
B137.6—17
Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings For Hot- and Cold-water Distribution Systems
Table P2906.4, Table P2906.5, Table 2906.6
B137.9—17
Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems
Table M2101.1, Table P2906.4
B137.10—17
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems
B137.11—17
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
Table P2906.4, Table P2906.5, Table P2906.6
B137.18—17
Polyethylene of Raised Temperature (PE-RT) Tubing Systems for Pressure Applications
Table M2101.1, Table M2105.4, Table M2105.5, Table P2906.4, Table P2906.5, Table P2906.6
B181.1—18
B181.2—18
B181.3—18
Polyolefin and polyvinylidene (PVDF) Laboratory Drainage Systems
B182.2—18
PSM Type polyvinylchloride (PVC) Sewer Pipe and Fittings
Table P3002.2, Table P3302.1
B182.4—18
Profile polyvinylchloride (PVC) Sewer Pipe & Fittings
Table P3002.2, Table P3302.1
B182.6—18
Profile Polyethylene (PE) Sewer Pipe and Fittings for leak-proof Sewer Applications
Table P3302.1
B182.8—18
Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings
Table P3302.1
B602—16
CSA C22.2 No. 60335-2-40—2019
Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers 3rd edition
CSA A257.1—2014
Table P3002.2
CSA B45.5—2017/IAPMO Z124—2017 with Errata dated August 2017
Plastic Plumbing Fixtures
CSSB
Cedar Shake & Shingle Bureau
P.O. Box 1178
Sumas, WA 98295-1178DASMA
Door & Access Systems Manufacturers Association International
1300 Sumner Avenue
Cleveland, OH 44115-2851105—2017
Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors
N1101.10.3
108—2017
Standard Method for Testing Garage Doors, Rolling Doors and Flexible Doors; Determination of Structural Performance Under Uniform Static Air Pressure Difference
115—2017
Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure
DHA
Decorative Hardwoods Association (formerly HPVA)
42777 Trade West Drive
Sterling, Virginia 20166DOC
United States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230PS 2—18
Performance Standard for Wood Structural Panels
DOTn
U.S. Department of Transportation
1200 New Jersey Avenue SE
Washington, DC 2059049 CFR, Parts 192.281(e) & 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards
FEMA
Federal Emergency Management Agency
500 C Street SW
Washington, DC 20472FM
FM Approvals
Headquarters Office
Norwood, MA 020624450—(1989)
Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992
4474—2011
American National Standard for Evaluating the Simulated Wind Uplift Resistance of Roof Assemblies Using Static Positive and/or Negative Differential Pressures
ANSI/FM 4880—(2017)
American National Standard for Evaluating the Fire Performance of Insulated Building Panel Assemblies and Interior Finish Materials
GA
Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville, MD 20782HVI
Home Ventilating Institute
1740 Dell Range Blvd., Suite H, PMB 450
Cheyenne, WY 82009916—18
Airflow Test Procedure
N1103.6.2
IAPMO
IAPMO Group
4755 E. Philadelphia Street
Ontario, CA 91761-USAICC
International Code Council, Inc.
500 New Jersey Avenue NW
Washington, DC 200016th Floor
ANSI/RESNET/ICC 301—2019
Standard for the Calculation and Labeling of the Energy Performance of Low-rise Dwelling and Sleeping Units Using the Energy Rating Index
N1106.4
ANSI/RESNET/ICC 380—2019
Standard for Testing Airtightness of Building, Dwelling Unit and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems and Airflow of Mechanical Ventilation Systems
N1102.4.1.2
SCBC—21
South Carolina Building Code®
R320.1.1, R101.2, R202, R301.1.1, R301.1.3, R301.2.1.1, R301.2.2.1.1, R301.2.2.1.2, R301.3, Table R302.1(1), Table R302.1(2), R302.2.1, R302.2.2, R302.3, R308.5, R320.1, R321.3, R403.1.8, Table R602.10.3(3), Table R606.12.2.1, R609.2, R802.1.5.4, R905.10.3, G2402.3
ICC 400—17
Standard on the Design and Construction of Log Structures
ICC 900/SRCC 300—2020
Solar Thermal System Standard
IECC—06
International Energy Conservation Code®
N1101.6
IECC—21
International Energy Conservation Code®
N1101.1, N1103.8, Table N1105.4.2(1)
IEEE
Institute of Electrical and Electronic Engineers, Inc.
3 Park Avenue, 17th Floor
New York, NY 10016-5997515.1—2012
IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications
N1103.5.2.2
ISO
International Organization for Standardization
Chemin de Blandonnet 8
Geneva, Switzerland CP 401 - 12148336—2009
Fibre-cement Flat Sheets-product Specification and Test Methods
15874—2002
Polypropylene Plastic Piping Systems for Hot and Cold Water Installations
Table M2101.1
MSS
Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, NE
Vienna, VA 22180SP-42—2013
Corrosion Resistant Gate, Globe, Angle and Check Valves with Flanged and Butt Weld Ends (Glasses 150, 300 & 600)
Table P2903.9.4
SP-58—2009
Pipe Hangers and Supports—Materials, Design, Manufacture, Selection, Application and Installation
SP-67—2011
Butterfly Valves
Table P2903.9.4
SP-70—2011
Gray Iron Gate Valves, Flanged and Threaded Ends
Table P2903.9.4
SP-71—2011
Gray Iron Swing Check Valves, Flanged and Threaded Ends
Table P2903.9.4
SP-78—2011
Cast Iron Plug Valves, Flanged and Threaded Ends
Table P2903.9.4
SP-80—2019
Bronze Gate, Globe, Angle and Check Valves
Table P2903.9.4
SP-110—2010
Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends
Table P2903.9.4
SP-122—2012
Plastic Industrial Ball Valves
Table P2903.9.4
SP-139—2014
Copper Alloy Gate, Globe, Angle, and Check Valves for Low Pressure/ Low Temperature Plumbing Applications
Table P2903.9.4
NAIMA
North American Insulation Manufacturers Association
11 Canal Center Plaza, Suite 101
Alexandria, VA 22314NEMA
National Electrical Manufacturers Association
1300 17th Street North No. 900
Arlington, VA 22209OS 4—2016
Requirements for Air-Sealed Boxes for Electrical and Communication Applications
N1102.4.6
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-747113D—19
Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes
13R—19
Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies
70—20
National Electrical Code
211—19
276—15
Standard Method of Fire Tests for Determining the Heat Release Rate of Roofing Assemblies with Combustible Above-deck Roofing Components
286—19
Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
501—17
Standard on Manufactured Housing
R202
720—15
Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment
NFRC
National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770200—2020
Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
N1101.10.3
NGWA
National Ground Water Association
601 Dempsey Road
Westerville, OH 43081NSF
NSF International
789 N. Dixboro Road
Ann Arbor, MI 4810550—2017
Equipment for Swimming Pools, Spas, Hot Tubs and Other Recreational Water Facilities
61—2018
Drinking Water System Components—Health Effects
358-1—2017
Polyethylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems
358-2—2017
Polypropylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems
Table M2105.4, M2105.5
358-3—2016
Cross-linked Polyethylene (PEX) Pipe and Fittings for Water-based Ground-source (Geothermal) Heat Pump Systems
Table M2105.4, Table M2105.5
358-4—2018
Polyethylene of Raised Temperature (PE-RT ) Pipe and Fittings for Water-based Ground-source (Geothermal) Heat Pump Systems
Table 2105.4, Table 2105.5
359—2016
Valves for Crosslinked Polyethylene (PEX) Water Distribution Tubing Systems
Table P2903.9.4
PCA
Portland Cement Association
5420 Old Orchard Road
Skokie, IL 60077SBCA
Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719ANSI/FS100—12(R2018)
Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies
BCSI—2018
Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
SMACNA
Sheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021TMS
The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501402—2016
Building Code Requirements for Masonry Structures
TPI
Truss Plate Institute
2670 Crain Highway, Suite 203
Waldorf, MD 20601UL
UL LLC
333 Pfingsten Road
Northbrook, IL 6006217—2008
103—2010
Factory-built Chimneys for Residential Type and Building Heating Appliances—with revisions through March 2017
127—2011
Factory-built Fireplaces—with revisions through July 2016
180—2012
Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids—with revisions through May 2017
181—2005
Factory-made Air Ducts and Air Connectors—with revisions through April 2017
181A—2013
Closure Systems for Use with Rigid Air Ducts and Air Connectors—with revisions through March 2017
181B—2013
Closure Systems for Use with Flexible Air Ducts and Air Connectors—with revisions through March 2017
263—2011
Fire Test of Building Construction and Materials—with revisions through March 2018
268—2016
Smoke Detectors for Fire Alarm Systems—with revisions through July 2016
515—11
Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015
N1103.5.1.2
580—2006
Test for Uplift Resistance of Roof Assemblies—with Revisions through October 2013
641—2010
Type L, Low-temperature Venting Systems—with revisions through April 2018
651—2011
Schedule 40, Type EB and A Rigid PVC Conduit and Fittings—with revisions through June 2016
723—2018
Standard for Test for Surface Burning Characteristics of Building Materials
790—04
Standard Test Methods for Fire Tests of Roof Coverings—with revisions through October 2018
834—2004
Heating, Water Supply and Power Boilers—Electric—with revisions through September 2018
1026—2012
Electric Household Cooking and Food Serving Appliances—with revisions through July 2018
1563—2009
1618—2015
Wall Protectors, Floor Protectors, and Hearth Extensions—with revisions through January 2018
1693—2010
Electric Radiant Heating Panels and Heating Panel Sets—with revisions through October 2011
1703—2002
Flat-plate Photovoltaic Modules and Panels—with revisions through September 2018
1738—2010
Venting Systems for Gas-burning Appliances, Categories II, III and IV
1741—2010
Inverters, Converters, Controllers and Interconnection System Equipment with Distributed Energy Resources—with revisions through February 2018
1777—07
Chimney Liners—with revisions through April 2014
1995—2015
Heating and Cooling Equipment—with revisions through August 2018
2034—2017
Standard for Single- and Multiple-station Carbon Monoxide Alarms—with revisions through September 2018
2075—2013
Gas and Vapor Detectors and Sensors—with revisions through December 2017
2158A—2013
Outline of Investigation for Clothes Dryer Transition Duct—with revisions through April 2017
2523—2009
Standard for Solid Fuel-fired Hydronic Heating Appliances, Water Heaters and Boilers—with revisions through March 2018
2703—2014
Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels—with revisions through December 2019
7103—19
Outline of Investigation for Building-Integrated Photovoltaic Roof Covering
61730-1—2017
Photovoltaic (PV) Module Safety Qualification—Part 1: Requirements for Construction
61730-2—2017
Photovoltaic (PV) Module Safety Qualification—Part 2: Requirements for Testing
UL/CSA 60335-2-40—2019
Standard for Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
ULC
ULC
13775 Commerce Parkway
Richmond, BC V6V 2V4US-FTC
United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580CFR Title 16(2015)
R-value Rule
N1101.10.4
WDMA
Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington, DC 20036-3309AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specifications for Windows, Doors and Skylights
I.S. 11—18
Industry Standard Analytical Method for Design Pressure (DP) Ratings of Fenestration Products
WMA
World Millwork Alliance (formerly Association of Millwork Distributors Standards AMD)
10047 Robert Trent Parkway
New Port Richey, FL 34655-4649ANSI WMA 100—2018
Standard Method of Determining Structural Performance Ratings of Side-Hinged Exterior Door Systems and Procedures for Component Substitution