Heads up: There are no amended sections in this chapter.

Chapter 15 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.


ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual D—2011 Residential Duct Systems 601.4, 603.2
183—2007
(reaffirmed 2011)
Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings 312.1

AHRI Air-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
reference
number
Title Referenced
in code
section number
700—2011
with Addendum 1
Purity Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3

AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
Title Referenced
in code
section number
550—08 Test Method for High Velocity Wind Driven Rain Resistant Louvers 401.5, 501.3.2


ANSI American National Standards Institute
11 West 42nd Street
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
Z21.8—1994 (R2002) Installation of Domestic Gas Conversion Burners 919.1

ASHRAE ASHRAE
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2013 ASHRAE Fundamentals Handbook 603.2
15—2013 Safety Standard for Refrigeration Systems 1101.6, 1105.8, 1108.1
34—2013 Designation and Safety Classification of Refrigerants 202, 1102.2.1, 1103.1
62.1—2013 Ventilation for Acceptable Indoor Air Quality 403.3.1.1.2.3.2
170—2008 Ventilation of Health Care Facilities 407
180—2012 Standard Practice for Inspection and Maintenance of Commercial
Building HVAC Systems
102.3

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—2011 Malleable Iron Threaded Fittings, Classes 150 & 300 Table 1202.5
B16.5—2009 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24 Table 1202.5
B16.9—2007 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—2011 Forged Fittings, Socket-welding and Threaded Table 1202.5
B16.15—2011 Cast Bronze Threaded Fittings Table 1202.5
B16.18—2012 Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—(R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.24—2011 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900,
1500 and 2500
Table 1202.5
B16.26—2011 Cast Copper Alloy Fittings for Flared Copper Tubes Table 1202.5
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 1202.5
B16.51—2011 Copper and Copper Alloy Press-Connect Pressure Fittings Table 1202.5
B31.5—2010 Refrigeration Piping and Heat Transfer Components 1107.1
B31.9—2011 Building Services Piping 1201.3
BPVC—2010/
2011 addenda
ASME Boiler & Pressure Vessel Code—07 Edition 1009.2, 1003.1, 1004.1, 1011.1
CSD-1—2011 Controls and Safety Devices for Automatically Fired Boilers 1004.1

ASSE American Society of Safety Engineers
1800 East Oakton Street
Des Plaines, IL 60018
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASSE Z359.1-2007 Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components,
Part of the Fall Protection Code
304.11

ASSE American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1017—2010 Performance Requirements for Temperature Actuated Mixing Values for
Hot Water Distribution Systems
1002.2.2

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—12 Specification for Pipe, Steel, Black and Hot-dipped,
Zinc-coated Welded and Seamless
Table 1202.4, Table 1202.5, Table 1302.3
A 106/A106M—11 Specification for Seamless Carbon Steel Pipe for High-Temperature Service Table 1302.3, Table 1202.5
Table 1202.4 Table 1302.3
A 126—09 Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings Table 1202.5
A 234/A234M—11a Standard Specification for Piping Fittings of Wrought Carbon Steel And Alloy Steel
For Moderate and High Temperature Service
Table 1202.5
A 254—97 (2007) Specification for Copper Brazed Steel Tubing Table 1202.4, Table 1302.3
A 395/A395M-99(2009) Standard Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at
Elevated Temperatures
Table 1202.5, Table 1302.3
A 420/A 420M—10A Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel
for Low-Temperature Service
Table 1202.5
A 536-84(2009) Standard Specification for Ductile Iron Castings Table 1202.5
A 539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and
Fuel Oil Lines
Table 1302.3
B 32—08 Specification for Solder Metal 1203.3.3
B 42—10 Specification for Seamless Copper Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1302.3
Table 1202.4, Table 1302.3
B 43—09 Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1302.3
Table 1202.4, Table 1302.3
B 68—11 Specification for Seamless Copper Tube, Bright Annealed 513.13.1
B75—11 Specification for Seamless Copper Tube Table 1302.3
B 88—09 Specification for Seamless Copper Water Tube 513.13.1, 1107.5.3, Table 1202.4, Table 1302.3
B 135—10 Specification for Seamless Brass Tube Table 1202.4
B 251—10 Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
513.13.1, Table 1202.4
B 280—08 Specification for Seamless Copper Tube for Air Conditioning and
Refrigeration Field Service
513.13.1, 1107.5.3, Table 1302.3
B 302—12 Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4, Table 1302.3
B 813—10 Specification for Liquid and Paste Fluxes for Soldering of Copper and
Copper Alloy Tube
1203.3.3
C 315—07(2011) Specification for Clay Flue Liners and Chimney Pots 801.16.1, Table 803.10.4
C 411—11 Test Method for Hot-surface Performance of High-temperature Thermal Insulation 604.3
D 56—05(2010) Test Method for Flash Point by Tag Closed Tester 202
D 93—12 Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe,
Schedules 40 and 80
Table 1202.4
D 1693—13 Test Method for Environmental Stress-Cracking of Ethylene Plastics Table 1202.4
D 1785—12 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe,
Schedules 40, 80 and 120
Table 1202.4, Table 1210.4
D 2235—04(2011) Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
1203.3.4
D 2241—09 Specification for Poly (Vinyl Chloride)(PVC)
Pressure-rated Pipe (SDR-Series)
Table 1202.4, Table 1210.4
D 2282—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 1202.4
D 2412—11 Test Method for Determination of External Loading Characteristics of Plastic Pipe
by Parallel-plate Loading
603.8.3
D2464—13 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC)
Plastic Pipe Fittings, Schedule 80
Table 1210.5
D 2466—06 Specification for Poly (Vinyl Chloride)(PVC)
Plastic Pipe Fittings, Schedule 40
Table 1202.5, Table 1210.5
D 2467—06 Specification for Poly (Vinyl Chloride)(PVC)
Plastic Pipe Fittings, Schedule 80
Table 1202.5, Table 1210.5
D 2564—12 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 1203.3.4
D 2657—07 Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings Table 1210.5
D 2683—2010E1 Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled
Polyethylene Pipe and Tubing
Table 1210.5, 1210.6.6.1
D2737—12A Standard Specification for Polyethylene (PE) Plastic Tubing Table 1210.4
D 2846/D 2846M—09BE1 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and
Cold Water Distribution Systems
Table 1210.4, Table 1202.4, 1203.3.4
D 2996—01(2007)e01 Specification for Filament-wound Fiberglass
(Glass Fiber Reinforced Thermosetting Resin) Pipe
Table 1302.3
D 3035—2012E1 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on
Controlled Outside Diameter
Table 1210.4
D 3261—12 Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for
Polyethylene (PE) Plastic Pipe and Tubing
Table 1210.5, 1210.6.6.1
D 3278—1996(2011) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D 3309—96a(2002) Specification for Polybutylene (PB) Plastic Hot and
Cold Water Distribution Systems
Table 1202.4, 1203.10.1
E 84—2013A Test Method for Surface Burning Characteristics of Building Materials 202, 510.9, 602.2,
602.2.1, 602.2.1.6, 602.2.1.6.1, 602.2.1.6.2,
602.2.1.6.3, 602.2.1.7, 604.3, 1204.1
E 119—2012a Test Method for Fire Tests of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1, 607.2.1
E 136—2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C 202
E 814—2013 Test Method for Fire Tests of Through-penetration Fire Stops 506.3.11.2, 506.3.11.3
E 1509—12 Specification for Room Heaters, Pellet Fuel-burning Type 904.1
E 2231—09 Standard Practice For Specimen Preparation and Mounting of Pipe and
Duct Insulation Materials to Assess Surface Burning Characteristics
604.3, 1204.1
E 2336—04(2013) Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems 506.3.6, 506.3.11.2
F437—09 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 1210.5
F 438—09 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Table 1202.5, Table 1210.5
F 439—12 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 1202.5, Table 1210.5
F 441/F 441M—13 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,
Schedules 40 and 80
Table 1202.4, Table 1210.4
F 442/F 442M—13 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe (SDR-PR)
Table 1202.4, Table 1210.4
F 493—10 Specification for Solvent Cements for Chlorinated Poly
(Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
1203.3.4
F 714—13 Standard Specification for Polyethylene (PE) Plastic Pipe
(SDR-PR) based on Outside Diameter
Table 1210.4
F 876—13 Specification for Cross-linked Polyethylene (PEX) Tubing Table 1202.4, Table 1210.4
F 877—2011A Specification for Cross-linked Polyethylene (PEX) Plastic Hot and
Cold Water Distribution Systems
Table 1202.4, Table 1202.5, Table 1210.4
F 1055—13 Specification for Electrofusion Type Polyethylene Fittings for
Outside Diameter Controlled Polyethylene and
Cross-linked Polyethylene Pipe and Tubing
Table 1210.5, 1210.6.6.2
F 1281—11 Specification for Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene
(PEX-AL-PEX) Pressure Pipe
Table 1202.4
F 1282—10 Standard Specification for Polyethylene/Aluminum/
Polyethylene (PE-AL-PE) Composite Pressure Pipe
Table 1202.4. Table 1210.4, Table 1210.5
F 1476—07 Specification for Performance of Gasketed Mechanical Couplings for Use in
Piping Applications
Table 1202.5, 1203.3.7
F 1548—01(2006) Standard Specification for the Performance of Fittings for Use with
Gasketed Mechanical Couplings Used in Piping Applications
Table 1202.5
F 1807—13 Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR 9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polethylene of
Raised Temperature (PE-RT) Tubing
,Table 1202.5, Table 1210.5
F 1924—12 Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled
Polyethylene Gas Distribution Pipe and Tubing
1210.6.6.3
F1960—12 Specification for Cold-Expansion Fittings with PEX Reinforcing Rings for Use with
Cross-linked Polyethylene (PEX) Tubing
Table 1202.5
F 1974—09 Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
Table 1202.5
F2080—12 Specification for Cold-Expansion Fittings with Metal Compression-Sleeves for
Cross-linked Polyethylene (PEX) Pipe
Table 1202.5
F2098—08 Standard Specification for Stainless Steel Clamps for SDR9 Cross-linked Polyethylene (PEX)
Tubing to Metal and Plastic Insert Fittings
Table 1202.5
F 2159—11 Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for
SDR 9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of
Raised Temperature (PE-RT) Tubing
Table 1210.5, Table 1202.5
F 2389—10 Specification for Pressure-rated Polypropylene Piping Systems Table 1210.4, 1203.15.1, 1210.6.7.1,
Table 1210.5, Table 1202.4, Table 1202.5
F2434—09 Standard Specification for Metal Insert Fittings Utilizing a
Copper Crimp ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and
SDR9 Cross-linked Polyethylene/Aluminum/
Cross-linked Polyethylene (PEX-AL-PEX) Tubing
Table 1210.5
F 2623—08 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1 Table 1202.4,
Table 1210.4
F 2735—09 Standard Specification for Plastic Insert Fittings for SDR 9 Cross-linked Polyethylene (PEX)
and Polyethylene of Raised Temperature (PE-RT) Tubing
Table 1202.5
F 2769—10 Polyethylene of Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and
Distribution Systems
Table 1210.5, Table 1202.4
F 2806—10 Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe
(Metric SDR-PR)
Table 1202.4

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
Standard
reference
number
Title Referenced
in code
section number
A5.8M/A5.8—2011 Specifications for Filler Metals for Brazing and Braze Welding 1203.3.1, 1303.3.1

AWWA American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C901—08 Polyethylene (PE) Pressure Pipe and
Tubing, 1/2 in. (13mm) through 3 in. (76mm) for Water Service
Table 1210.4
C110/A21.10—12 Standard for Ductile Iron & Gray Iron Fittings Table 1202.5
C115/A21.15—11 Standard for Flanged Ductile-Iron Pipe with Ductile Iron or Grey-Iron Threaded Flanges Table 1202.4
C151/A21.51—09 Standard for Ductile-Iron Pipe, Centrifugally Cast for Water Table 1202.4
C153/A21.53—11 Standard for Ductile-Iron Compact Fittings for Water Service Table 1202.5

CSA CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516
Standard
reference
number
Title Referenced
in code
section number
B137.2—13 Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Applications Table 1210.5
B137.3—13 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications Table 1210.5
B137.6—13 Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot- and
Cold-water Distribution Systems
Table 1210.5
B137.9—13 Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure-Pipe Systems
Table 1210.4, Table 1210.5, Table 1202.4
B137.10—13 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure-Pipe Systems
Table 1202.4
CSA C448 Series—02
CAN/CSA 2002
Design and Installation of Earth Energy Systems—First Edition; Update 2: October 2009;
 Consolidated Reprint 10/2009
Table 1210.5
CSA B137.1—13 Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services Table 1210.4, Table 1210.5
CSA B137.5—13 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications Table 1210.4, Table 1210.5
CSA B137.11—13
ANSI CSA
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications Table 1210.4, Table 1210.5
America FC1—2012 Stationary Fuel Cell Power Systems 924.1

DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000
(2009)
Air Contaminants 502.6
29 CFR Part 1910.1025
(2009)
Toxic and Hazardous Substances 502.19


FS Federal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington, DC 20407
Standard
reference
number
Title Referenced
in code
section number
WW-P-325B (1976) Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and
Waste Applications)
Table 1202.4
*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
SCBC—15 South Carolina Building Code 201.3, 202, 301.15, 301.16, 301.17, 301.18,
302.1, 302.2, 304.8, 304.11, 308.4.2.2, 308.4.2.4,
401.4, 401.5, 406.1, 501.3.1, 501.3.2, 501.10.2, 502.10,
502.10.1, 504.2, 504.10, 505.3, 506.3.3, 506.3.10, 506.3.12.2,
506.4.1, 509.1, 510.6, 510.6.3, 510.6.2, 510.7, 510.7.1.1, 510.7.2,
510.7.3, 510.8, 511.1.5, 513.1, 513.2, 513.3, 513.4.3, 513.5, 513.5.2,
513.5.2.1, 513.5.3, 513.5.3.2, 513.6.2, 513.10.5, 513.11.1, 513.12,
513.12.2, 513.20, 601.3, 602.2, 602.2.1.5.1, 602.2.1.5.2, 602.2.1.6.1, 602.2.1.6.2,
602.3, 602.4, 603.1, 603.10, 603.13, 603.18.2, 604.5.4, 607.1.1, 607.1.2,
607.3.2.1, 607.5.1, 607.5.2, 607.5.3, 607.5.4, 607.5.4.1, 607.5.5,
607.5.5.1, 607.5.6, 607.6, 607.6.1, 607.6.2, 607.6.2.1, 607.6.3,
701.2, 701.4.1, 701.4.2, 801.3, 801.16.1, 801.18.4, 801.18.4.1, 902.1, 908.3, 908.4,
910.3, 924.1, 925.1, 926.1, 927.2, 928.1, 1004.6, 1105.1, 1206.4,
1210.8.2, 1305.2.1, 1402.4, 1402.4.1
IECC—15 International Energy Conservation Code® 301.2, 303.3, 312.1, 401.2, 514.1, 604.1, 1204.1, 1204.2
SCFC—15 South Carolina Fire Code 201.3, 310.1, 311.1, 502.4, 502.5,
502.7.2, 502.8.1, 502.9.1, 502.9.5, 502.9.5.2, 502.9.5.3,
502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.9.11, 502.10,
502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.5, 511.1.1, 513.1, 513.2,
513.6.3, 513.12.1, 513.12.3, 513.12.4, 513.15, 513.16, 513.17, 513.18,
513.19, 606.2.1, 606.4.1, 908.7, 924.1, 926.1, 1101.9, 1105.3, 1105.9,
1106.5, 1106.6, 1301.1, 1301.2, 1301.5
SCFGC—15 South Carolina Fuel Gas Code 101.2, 201.3, 301.6, 701.1, 801.1, 901.1, 906.1, 926.1, 1101.5
SCPC—15 South Carolina Plumbing Code 201.3, 301.11, 307.2.2, 512.2, 908.5, 928.1, 1002.1, 1002.2,
1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4,
1201.1, 1206.2, 1206.3, 1210.8.1, 1401.2
SCRC—15 South Carolina Residential Code 101.2


IIAR International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
Standard
reference
number
Title Referenced
in code
section number
2—2014 Standard for Safe Design of Closed-circuit Ammonia Refrigeration Systems 1101.6, 1105.6.3

MSS Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
Standard
reference
number
Title Referenced
in code
section number
SP 58—2009 Pipe Hangers and Supports—Materials Design and Manufacture, Selection,
Application and Installation
305.4

NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
AH116—09 Fibrous Glass Duct Construction Standards 603.5, 603.9

NBBI National Board of Boiler and Pressure Vessel Inspectors
1055 Crupper Avenue
Columbus, OH 43229-1183
Standard
reference
number
Title Referenced
in code
section number
NBIC—2011 National Board Inspection Code, Part 3 1003.3

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
30A—15 Code for Motor Fuel-dispensing Facilities and Repair Garages 304.6
31—11 Standard for the Installation of Oil-burning Equipment 701.1, 801.2.1, 801.18.1, 801.18.2, 920.2,
922.1, 1308.1
37—15 Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines 915.1, 915.2
58—14 Liquefied Petroleum Gas Code 502.9.10
69—14 Standard on Explosion Prevention Systems 510.9.3
70—14 National Electrical Code 301.7, 306.3.1, 306.4.1, 511.1.1, 513.11,
513.12.2, 602.2.1.1, 927.2, 1104.2.2, 1106.3, 1106.4
72—13 National Fire Alarm and Signaling Code 606.3
82—14 Standard on Incinerators and Waste and Linen Handling Systems and Equipment 601.1
85—15 Boiler and Combustion Systems Hazards Code 1004.1
91—15 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and
Noncombustible Particulate Solids
502.9.5.1, 502.17
92—15 Standard for Smoke Control Systems 513.7, 513.8
96—14 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations 507.1
211—13 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 806.1
262—15 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for
Use in Air-handling Spaces
602.2.1.1
286—15 Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
602.2.1.6.2
704—12 Standard System for Identification of the Hazards of Materials for
Emergency Response
502.8.4, Table 1103.1, 510.1
853—15 Standard on Installation of Stationary Fuel Power Plants 924.1

NSF NSF International
789 Dixboro Road, P. O. Box 130140
Ann Arbor, MI 48113-0140
Standard
reference
number
Title Referenced
in code
section number
NSF 14-2011 Plastic Piping System Components and Related Materials 301.4
NSF 358-1-2011 Polyethylene Pipe and Fittings for Water Based Ground Source
"Geothermal" Heat Pump Systems
Table 1210.4, Table 1210.5

SMACNA Sheet Metal & Air-Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
Title Referenced
in code
section number
SMACNA/ANSI—2005 HVAC Duct Construction Standards-Metal and
Flexible 3rd Edition (ANSI)
603.4, Table 603.4, 603.9, 603.10
SMACNA—10 Fibrous Glass Duct Construction Standards 603.5, 603.9

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
17—2008 Vent or Chimney Connector Dampers for Oil-fired Appliances
with revisions Through January 2010
803.6
103—2010 Factory-built Chimneys, Residential Type and Building Heating Appliance
with revisions through July 2012
805.2
127—2011 Factory-built Fireplaces 903.1, 903.3, 903.4
174—04 Household Electric Storage Tank Water Heaters—with revisions through September 2012 1002.1
180—2012 Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids 1306.4
181—05 Factory-made Air Ducts and Air Connectors—
with revisions through October 2008
512.2, 603.5, 603.6.1,
603.6.2, 603.9, 604.13
181A—2013 Closure Systems for Use with Rigid Air Ducts and Air Connectors 603.9
181B—2013 Closure Systems for Use with Flexible Air Ducts and Air Connectors 603.9
197—10 Commercial Electric Cooking Appliances—with revisions through June 2011 917.1
207—2009 Refrigerant-containing Components and Accessories, Nonelectrical 1101.2
263—2011 Standard for Fire Test of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1, 607.6.2.1
268—2009 Smoke Detectors for Fire Alarm Systems 606.1
268A—2008 Smoke Detectors for Duct Application—with revisions through September 2009 606.1
343—2008 Pumps for Oil-Burning Appliances—with revisions through June 2013 1302.7
378—06 Draft Equipment—with revisions through January 2010 804.3, 804.3.8
391—2010 Solid-fuel and Combination-fuel Central and Supplementary Furnaces
with revisions through March 2010
918.1
412—2011 Refrigeration Unit Coolers—with revisions through August 2012 1101.2
471—2010 Commercial Refrigerators and Freezers—with revisions through December 2012 1101.2
499—05 Electric Heating Appliances—with revisions through February 2013 912.1, 923.1
508—99 Industrial Control Equipment—with revisions through March 2013 307.2.3
536—97 Flexible Metallic Hose—with revisions through June 2003 1302.8
555—06 Fire Dampers—with revisions through May 2012 607.3.1
555C—06 Ceiling Dampers—with revisions through May 2010 607.3.1
555S—99 Smoke Dampers—with revisions through May 2012 607.3.1
586—2009 High-Efficiency, Particulate, Air Filter Units 605.2
641—2010 Type L Low-temperature Venting Systems—with revisions through May 2013 802.1
705—2004 Standard for Power Ventilators—with revisions through March 2012 504.5
710—2012 Exhaust Hoods for Commercial Cooking Equipment 507.1
710B—2011 Recirculating Systems 507.1, 507.2
723—2008 Standard for Test for Surface Burning Characteristics of Building Materials 510.9, 602.2, 602.2.1,
602.2.1.6, 602.2.1.6.2, 602.2.1.6.3, 602.2.1.7, 604.3, 1204.1
726—95 Oil-fired Boiler Assemblies—with revisions through April 2011 916.1, 1004.1
727—06 Oil-fired Central Furnace—with revisions through April 2010 918.1
729—03 Oil-fired Floor Furnaces—with revisions through August 2012 910.1
730—03 Oil-fired Wall Furnaces—with revisions through August 2012 909.1
731—95 Oil-fired Unit Heaters—with revisions through August 2012 920.1
732—95 Oil-fired Storage Tank Water Heaters—with revisions through April 2010 1002.1
737—2011 Fireplace Stoves 905.1
762—2010 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances 506.5.1
791—06 Residential Incinerators—with revisions through April 2010 907.1
834—04 Heating, Water Supply and Power Boilers Electric—with revisions through January 2013 1004.1
842—07 Valves for Flammable Fluids—with revisions through October 2012 1307.1
858—05 Household Electric Ranges—with revisions through April 2012 917.1
867—2011 Electrostatic Air Cleaners—with revisions through February 2013 605.2
875—09 Electric Dry Bath Heater—with revisions through November 2011 914.2
896—93 Oil-burning Stoves—with revisions through August 2012 917.1, 922.1
900—04 Air Filter Units—with revisions through February 2012 605.2
907—94 Fireplace Accessories—with revisions through April 2010 902.2
923—2013 Microwave Cooking Appliances 917.1
959—2010 Medium Heat Appliance Factory-built Chimneys 805.5
1046—2010 Grease Filters for Exhaust Ducts—with revisions through January 2012 507.2.8
1240—2012 Electric Commercial Clothes—Drying Equipment—with revisions through October 2012 913.1
1261—01 Electric Water Heaters for Pools and Tubs—with revisions through July 2012 916.1
1453—04 Electric Booster and Commercial Storage Tank Water Heaters
with revisions through July 2011
1002.1
1479—03 Fire Tests of Through-penetration Firestops—
with revisions through October 2012
506.3.11.2, 506.3.11.3
1482—2011 Solid-fuel Type Room Heaters 905.1
1618—09 Wall Protectors, Floor Protectors and Hearth Extensions—
with revisions through May 2013
308.4.1, 903.2, 905.3
1777—2007 Chimney Liners—with revisions through July 2009 801.16.1, 801.18.4
1812—2013 Standard for Ducted Heat Recovery Ventilators 514.1
1815—2012 Standard for Nonducted Heat Recovery 514.1
1820—04 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—
with revisions through May 2013
602.2.1.3
1887—04 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—
with revisions through May 2013
602.2.1.2
1978—2010 Grease Ducts 506.3.2, 506.3.6
1995—2011 Heating and Cooling Equipment 908.1, 911.1, 918.1, 918.2, 1101.2
1996—2009 Electric Duct Heaters—with revisions through November 2011 911.1
2024—2011 Standard for Safety Optical-Fiber and Communications Cable Raceway—
with revisions through April 2011
602.2.1.1
2043—2008 Fire Test for Heat and Visible Smoke Release for Discrete Products and their
Accessories Installed in Air-handling Spaces
602.2.1.4.2
2158—97 Electric Clothes Dryers—with revisions through March 2009 913.1
2158A—2010 Outline of Investigation for Clothes Dryer Transition Duct 504.8.3
2162—01 Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type 917.1
2200—2012 Stationery Engine Generator Assemblies—with revisions through June 2013 915.1
2221—2010 Tests of Fire Resistive Grease Duct Enclosure Assemblies 506.3.11.3
2518—05 Air Dispersion System Materials 603.17
2523—09 Solid Fuel-fired Hydronic Heating Appliances—with revisions through February 2013 1002.1, 1004.1
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING