Chapter 15 Referenced Standards

Amendment
This section has been amended by the state, county, or city.
User note:
About this chapter: This code contains numerous references to standards that are used to provide requirements for materials and methods of construction. Chapter 15 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.
ANSI
American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY 10036
Z21.22—99 (R2003)
Relief Valves for Hot Water Supply Systems with Addenda Z21.22a—2000 (R2003) and Z21.22b—2001 (R2003)
ASHRAE
ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329
ASHRAE 18—2008 (RA13)
Method of Testing for Rating Drinking-Water Coolers with Self-contained Mechanical Refrigeration (ANSI/ASHRAE Approved)
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990
A112.1.2—2012
Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water Connection Receptors)
A112.1.3—2000 (R2015)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances
A112.3.1—2007 (R2012)
Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground
ASME A112.3.4—2013/CSA B45.9—2013
Macerating Toilet Systems and Related Components
A112.4.1—2009
A112.4.2—2015/CSA B45.16—15
Water Closet Personal Hygiene Devices
A112.4.3—1999 (R2010)
Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System
A112.4.14—2004 (R2016)
Manually Operated, Quarter-turn Shutoff Valves for Use in Plumbing Systems
A112.6.2—2000 (R2016)
Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks
A112.6.3—2001 (R2016)
Floor and Trench Drains
A112.6.4—2003 (R2012)
Roof, Deck, and Balcony Drains
A112.6.7—2010 (R2015)
Sanitary Floor Sinks
A112.6.9—2005(R2015)
Siphonic Roof Drains
A112.14.1—2003 (R2012)
A112.14.3—2016
A112.14.4—2001 (R2012)
Grease Removal Devices
A112.14.6—2010 (R2015)
FOG (Fats, Oils and Greases) Disposal Systems
A112.18.1—2017/CSA B125.1—2017
A112.18.2—2015/CSA B125.2—15
A112.18.3—2002 (R2012)
Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings
A112.18.6—2017/CSA B125.6—17
Flexible Water Connectors
A112.18.9—2011
Protectors/Insulators for Exposed Waste and Supplies on Accessible Fixtures
A112.19.1—2013/CSA B45.2—2013
Enameled Cast Iron and Enameled Steel Plumbing Fixtures
A112.19.2—2013/CSA B45.1—13
A112.19.3—2008/CSA B45.4—08(R2013)
Stainless Steel Plumbing Fixtures
A112.19.5—2017/CSA B45.15—2017
Flush Valves and Spuds for Water-closets, Urinals, and Tanks
A112.19.7M—2017/CSA B45.10—17
Hydromassage Bathtub Systems
A112.19.12—2014
Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Waste Systems
A112.19.14—2013
Six-liter Water Closets Equipped with a Dual Flushing Device
A112.19.15—2012
Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors
A112.19.19—2006(R2011)
Vitreous China Nonwater Urinals
A112.21.3—1985(R2007)
Hydrants for Utility and Maintenance Use
A112.36.2M—1991(R2012)
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—15
Anti-Siphon Fill Valves
ASSE 1016—2017/ASME A112.1016—2017/CSA B125.16—2017
Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—
Pressurized Flushing Devices for Plumbing Fixtures
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.1070—15
Water Temperature Limiting Devices
B1.20.1—2013
Pipe Threads, General Purpose (inch)
B16.3—2016
Malleable Iron Threaded Fittings Classes 150 and 300
B16.4—2016
Gray Iron Threaded Fittings Classes 125 and 250
B16.9—2012
Factory-made Wrought Steel Buttwelding Fittings
B16.11—2016
Forged Fittings, Socket-welding and Threaded
B16.12—2009 (R2014)
Cast-iron Threaded Drainage Fittings
B16.15—2013
Cast Alloy Threaded Fittings: Class 125 and 250
B16.18—2012
Cast Copper Alloy Solder Joint Pressure Fittings
B16.22—2013
Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
B16.23—2016
Cast Copper Alloy Solder Joint Drainage Fittings DWV
B16.26—2016
Cast Copper Alloy Fittings for Flared Copper Tubes
B16.28—1994
Wrought Steel Buttwelding Short Radius Elbows and Returns
B16.29—2012
Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV)
B16.34—2015
Valves Flanged, Threaded and Welding End
B16.51—2013
Copper and Copper Alloy Press-connect Pressure Fittings
ASPE
American Society of Plumbing Engineers
6400 Shafer Ct., Suite 350
Rosemont IL 60018-4914
45—2013
Siphonic Roof Drainage Systems
ASSE
ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena IL 60448
1001—2016
Performance Requirements for Atmospheric Type Vacuum Breakers
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—15
1003—09
Performance Requirements for Water Pressure Reducing Valves
1004—2016
Performance Requirements for Commercial Dishwashing Machines
1005—99
Performance Requirements for Water Heater Drain Valves
1008—06
Performance Requirements for Plumbing Aspects of Food Waste Disposer Units
1010—04
Performance Requirements for Water Hammer Arresters
1011—2016
Performance Requirements for Hose Connection Vacuum Breakers
1012—09
Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent
1013—2017
Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers
1015—2017
Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
ASSE 1016—2017/ASME A112.1016—2017/CSA B125.16—2017
Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings
1017—2010
Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems
1018—2017
Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied
1019—2016
Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type
1020—04
Performance Requirements for Pressure Vacuum Breaker Assembly
1022—2016
Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment
1024—2016
Performance Requirements for Dual Check Valve Type Backflow Preventers, Anti-siphon-type, Residential Applications
1035—08
Performance Requirements for Laboratory Faucet Backflow Preventers
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Pressurized Flushing Devices for Plumbing Fixtures
1044—2010
Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types
1047—2017
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
1048—2017
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
1049—2009
Performance Requirements for Individual and Branch Type Air Admittance Valves for Chemical Waste Systems
1050—2009
Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
1051—2009
Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systemsfixture and Branch Devices
1052—2016
Performance Requirements for Hose Connection Backflow Preventers
1055—2016
Performance Requirements for Chemical Dispensing Systems
1056—2013
Performance Requirements for Spill Resistant Vacuum Breaker
1060—2016
Performance Requirements for Outdoor Enclosures for Fluid Conveying Components
1061—2015
Performance Requirements for Push Fit Fittings
1062—2016
Performance Requirements for Temperature Actuated, Flow Reduction (TAFR) Valves to Individual Supply Fittings
1066—2016
Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings
1069—05
Performance Requirements for Automatic Temperature Control Mixing Valves
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.70—15
Water-temperature Limiting Devices
1071—2012
Performance Requirements for Temperature Actuated Mixing Valves for Plumbed Emergency Equipment
1072—07
Performance Requirements for Barrier Type Floor Drain Tap Seal Protection Devices
1079—2005
Performance Requirements for Dielectric Pipe Unions
5013—2015
Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)
5015—2015
Performance Requirements for Testing Double Check Valve Backflow Prevention Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF)
5020—2015
Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA)
5047—2015
Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA)
5048—2015
Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)
5052—98
Performance Requirements for Testing Hose Connection Backflow Preventers
5056—2015
Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB)
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959
A53/A53M—12
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless
A74—15
Specification for Cast-iron Soil Pipe and Fittings
A312/A312M—15a
Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes
A733—15
Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples
A778/A778M—15
Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products
A888—15
Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application
B32—08(2014)
Specification for Solder Metal
B42—15a
Specification for Seamless Copper Pipe, Standard Sizes
B43—15
Specification for Seamless Red Brass Pipe, Standard Sizes
B75/B75M—11
Specification for Seamless Copper Tube
B88—14
Specification for Seamless Copper Water Tube
B152/B152M—13
Specification for Copper Sheet, Strip Plate and Rolled Bar
B251—10
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B302—12
Specification for Threadless Copper Pipe, Standard Sizes
B306—13
Specification for Copper Drainage Tube (DWV)
B447—12a
Specification for Welded Copper Tube
B687—99(2011)
Specification for Brass, Copper and Chromium-plated Pipe Nipples
B813—10
Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube
B828—02(2010)
Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings
C4—04(2014)
Specification for Clay Drain Tile and Perforated Clay Drain Tile
C14—15a
Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe
C76—15a
Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe
C425—04(2013)
Specification for Compression Joints for Vitrified Clay Pipe and Fittings
C443—12
Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets
C564—14
Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings
C700—13
Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated
C1053—00(2010)
Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications
C1173—10(2014)
Specification for Flexible Transition Couplings for Underground Piping System
C1277—15
Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings
C1440—08(2013)
Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
C1460—2012
Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground
C1461—08(2013)
Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use
C1540—15
Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings
C1563—08(2013)
Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications
D1253—14
Standard Test Method For Residual Chlorine in Water
D1527—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1785—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
D2235—04(2011)
Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings
D2239—12a
Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter
D2241—15
Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)
D2282—99(2005)
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)
D2464—15
Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2466—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
D2467—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2468—96a
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40
D2564—12
Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems
D2609—15
Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe
D2657—07
Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Waste, and Vent Pipe and Fittings
D2661—14
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings
D2665—14
Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
D2672—14
Specification for Joints for IPS PVC Pipe Using Solvent Cement
D2683—14
Standard Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
D2729—11
Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D2737—2012a
Specification for Polyethylene (PE) Plastic Tubing
D2751—05
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings
D2846/D2846M—14
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems
D2855—96(2010)
Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings
D2949—10
Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
D3034—14a
Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D3035—15
Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter
D3138—04(2011)
Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-pressure Piping Components
D3139—98(2011)
Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals
D3212—07(2013)
Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
D3261—12e1
Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing
D3311—11
Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns
D4068—15
Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane
D4551—12
Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane
E2635—14
Standard Practice for Water Conservation Through In-Situ Water Reclamation
E2727—10e1
Standard Practice for the Assessment of Rainwater Quality
F405—05
Specification for Corrugated Polyethylene (PE) Pipe and Fittings
F409—12
Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings
F437—15
Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F438—15
Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
F439—13
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F441/F441M—15
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,Schedules 40 and 80
F442/F442M—13e1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)
F477—14
Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
F493—14
Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
F628—12e1
Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core
F656—15
Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings
F667—12
Standard Specification for 3 through 24 in. Corrugated Polyethylene Pipe and Fittings
F714—2013
Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F876—15a
Specification for Cross-linked Polyethylene (PEX) Tubing
F877—11a
Specification for Cross-linked Polyethylene (PEX) Hot- and Cold-water Distribution Systems
F891—10
Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core
F1055—13
Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Cross-linked Polyethylene Pipe and Tubing
F1281—11
Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe
F1282—10
Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
F1412—09
Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage
F1476—07(2013)
Standard Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications
F1488—14
Specification for Coextruded Composite Pipe
F1548—01(2012)
Standard Specification for the Performance of Fittings for Use with Gasketed Mechanical Couplings Used in Piping Applications
F1673—10
Standard Specification for Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems
F1807—15
Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F1866—13
Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
F1960—15
Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
F1970—12e1
Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) OR Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
F1974—09(2015)
Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/ Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
F1986—01(2011)
Specification for Multilayer Pipe, Type 2, Compression Fittings and Compression Joints for Hot and Cold Drinking Water Systems
F2080—15
Specifications for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe
F2098—08
Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Fittings
F2159—14
Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F2262—09
Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9
F2306/F2306M—14e1
12" to 60" Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications
F2389—15
Specification for Pressure-rated Polypropylene (PP) Piping Systems
F2434—14
Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX AL-PEX) Tubing
F2648/F2648M—13
Standard Specification for 2 to 60 inch [50 to 1500 mm] Annular Corrugated Profile Wall Polyethylene (PE) Pipe and Fittings for Land Drainage Applications
F2735—09
Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
F2736—13e1
Standard Specification for 6 to 30 in. [152 to 762 mm] Polypropylene (PP) Corrugated Single Wall Pipe and Double Wall Pipe
F2764/F2764M—11ae2
Standard Specification for 30 to 60 in. [750 to 1500 mm] Polypropylene (PP) Triple Wall Pipe and Fittings for Non-pressure Sanitary Sewer Applications
F2769—14
Polyethylene or Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and Distribution Systems
F2831—12
Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used in Rehabilitation of Metallic Pressurized Piping Systems
F2855—12
Standard Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC/AL/ CPVC) Composite Pressure Tubing
F2881—11
Standard Specification for 12 to 60 in. [300 to 1500 mm] Polypropylene (PP) Dual Wall Pipe and Fittings for Non-pressure Storm Sewer Applications
AWS
American Welding Society
8669 NW 36 Street, #130
Miami FL 33166
A5.8M/A5.8—2011
Specifications for Filler Metals for Brazing and Braze Welding
AWWA
American Water Works Association
6666 West Quincy Avenue
Denver CO 80235
C104/A21.4—13
Cement-mortar Lining for Ductile-iron Pipe and Fittings
C110/A21.10—12
Ductile-iron and Gray-iron Fittings
C111/A21.11—12
Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings
C115/A21.15—11
Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
C151/A21.51—09
Ductile-iron Pipe, Centrifugally Cast for Water
C153—00/A21.53—11
Ductile-iron Compact Fittings for Water Service
C500—09
Standard for Metal-seated Gate Valves for Water Supply Service
C504—10
Standard for Rubber-Seated Butterfly Valves
C507—15
Standard for Ball Valves, 6 In. Through 60 in. (150 mm through 1,500 mm).
C510—07
Double Check Valve Backflow Prevention Assembly
C511—07
Reduced-pressure Principle Backflow Prevention Assembly
C651—14
Disinfecting Water Mains
C652—11
Disinfection of Water-storage Facilities
C901—16
Polyethylene (PE) Pressure Pipe and Tubing 3/4 inch (19 mm) Through 3 inch (76 mm) for Water Service
C904—16
Cross-linked Polyethylene (PEX) Pressure Tubing 1/2 inch (13 mm) Through 3 inch (76 mm) for Water Service
CISPI
Cast Iron Soil Pipe Institute
2401 Fieldcrest Dr.
Mundelein IL 60060
301—12
Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
310—12
Specification for Coupling for Use in Connection with Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516
A257.1M—14
Non-reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.2M—14
Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.3M—14
Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets
ASME A112.18.1—2017/CSA B125.1—17
ASME A112.18.2—2015/CSA B125.2—2015
ASME A112.19.1—2013/CSA B45.2—2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
ASME A112.19.2—2013/B45.1—2013
ASME A112.19.3—2008/CSA B45.4—08(R2013)
Stainless-steel Plumbing Fixtures
ASME A112.19.5—2017/CSA B45.15—17
Flush Valves and Spuds for Water Closets, Urinals and Tanks
ASME A112.19.7—2017/CSA B45.10—17
Hydromassage Bathtub Systems
CSA B45.5—17/IAPMO Z124—2017
ASME A112.3.4—2013/CSA B45.9—13
Macerating Systems and Related Components
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—2015
Anti-Siphon Fill Valves
ASSE 1016/ASME A112.1016/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Pressurized Flushing Devices for Plumbing Fixtures
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.1070—2015
Water Temperature Limiting Devices
B64.1.1—16
Vacuum Breakers, Atmospheric Type (AVB)
B64.1.2—16
Pressure Vacuum Breakers, (PVB)
B64.1.3—16
Spill Resistant Pressure Vacuum Breakers (SRPVB)
B64.2—16
Vacuum Breakers, Hose Connection Type (HCVB)
B64.2.1—16
Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature
B64.2.1.1—16
Hose Connection Dual Check Vacuum Breakers (HCDVB)
B64.2.2—16
Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature
B64.3—16
Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)
B64.4—16
Backflow Preventers, Reduced Pressure Principle Type (RP)
B64.4.1—16
Reduced Pressure Principle for Fire Sprinklers (RPF)
B64.5—16
Double Check Backflow Preventers (DCVA)
B64.5.1—16
Double Check Valve Backflow Preventer for Fire Systems (DCVAF)
B64.6—16
Dual Check Valve (DuC) Backflow Preventers
B64.7—16
Laboratory Faucet Vacuum Breakers (LFVB)
B64.10—16
Manual for the Selection and Installation of Backflow Prevention Devices
B64.10.1—11
Maintenance and Field Testing of Backflow Preventers
B79—08(R2013)
Commercial and Residential Drains and Cleanouts
B137.1—16
Polyethylene (PE) Pipe, Tubing and Fittings for Cold-water Pressure Services
B137.2—16
Polyvinylchloride, PVC, Injection-moulded Gasketed Fittings for Pressure Applications
B137.3—16
Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
B137.5—16
Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
B137.6—16
CPVC Pipe, Tubing and Fittings for Hot- and Cold-water Distribution Systems
B137.9—16
Polyethylene Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-pipe Systems
B137.10—16
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Composite Pressure-pipe Systems
B137.11—16
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
B137.18—13
Polyethylene of Raised Temperature Resistance (PE-RT) Tubing Systems for Pressure Applications
B181.1—15
Acrylonitrile-Butadiene-Styrene ABS Drain, Waste and Vent Pipe and Pipe Fittings
B181.2—15
Polyvinylchloride PVC and Chlorinated Polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings
B181.3—15
Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems
B182.1—11
Plastic Drain and Sewer Pipe and Pipe Fittings
B182.2—11
PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings
B182.4—15
Profile Polyvinylchloride PVC Sewer Pipe and Fittings
B182.6—15
Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-proof Sewer Applications
B182.8—15
Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings
B182.13—11
Profile Polypropylene (PP) Sewer Pipe and Fittings for Leak-proof Sewer Applications
B356—10
Water Pressure Reducing Valves for Domestic Water Systems
B481.1—12
Testing and Rating of Grease Interceptors Using Lard
B481.3—12
Sizing, Selection, Location and Installation of Grease Interceptors
B483.1—07(R2012)
Drinking Water Treatment Units
B602—15
Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe
IAPMO
IAPMO Group
4755 E. Philadelphia Street
Ontario CA 91761 USA
Z1001—2014
CSA B45.5—17/IAPMO Z124—2017
IAPMO/ANSI Z1157—2014
Ball Valves
ICC
International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001
A117.1—2009
Accessible and Usable Buildings and Facilities
ICC 900/SRCC 300—2015
Solar Thermal System Standard
ISEA
International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington VA 22209
ANSI/ISEA Z358.1—2014
Emergency Eyewash and Shower Equipment
MSS
Manufacturers Standardization Society of the Valve and Fittings Industry, Inc.
127 Park St. NE
Vienna VA 22180-4602
SP-67—2011
Butterfly Valves
SP-70—2013
Gray Iron Gate Valves, Flanged and Threaded Ends
SP-71—2013
Gray Iron Swing Check Valves, Flanged and Threaded Ends
SP-72—2010a
Ball Valves with Flanged or Butt-welding Ends for General Service
SP-78—2013
Cast Iron Plug Valves, Flanged and Threaded Ends
SP-80—2013
Bronze Gate, Globe, Angle and Check Valves
SP-110—2010a
Ball Valves, Threaded, Socket Welding, Solder Joint, Grooved and Flared Ends
SP-122—2012
Plastic Industrial Ball Valves
SP-139—2014
Copper Alloy Gate, Globe, Angle and Check Valves for Low Pressure/Low Temperature Plumbing Applications
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
51—18
Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes
55—16
Compressed Gases and Cryogenic Fluids Code
70—17
National Electric Code
99—18
Health Care Facilities Code
NGWA
National Ground Water Association
601 Dempsey Road
Westerville OH 43081
ANSI/NGWA 01—14
Water Well Construction Standard
NSF
NSF International
789 N. Dixboro Road P.O. Box 130140
Ann Arbor MI 48105
3—2012
Commercial Warewashing Equipment
14—2015
Plastic Piping System Components and Related Materials
18—2012
Manual Food and Beverage Dispensing Equipment
42—2015
Drinking Water Treatment Units-Aesthetic Effects
44—2015
Residential Cation Exchange Water Softeners
50—2015
Equipment for Swimming Pools, Spas, Hot Tubs and Other Recreational Facilities
53—2015
Drinking Water Treatment Units—Health Effects
58—2015
Reverse Osmosis Drinking Water Treatment Systems
61—2015
Drinking Water System Components—Health Effects
62—2015
Drinking Water Distillation Systems
184—2014
Residential Dishwashers
350—2014
Onsite Residential and Commercial Water Reuse Treatment Systems
359—2011
Valves for Cross-linked Polyethylene (PEX) Water Distribution Tubing Systems
372—2011
Drinking Water Systems Components—Lead Content
PDI
Plumbing and Drainage Institute
800 Turnpike Street, Suite 300
North Andover MA 01845
PDI G101(2012)
Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data
PDI G102(2009)
Testing and Certification for Grease Interceptors with Fog Sensing and Alarm Devices
PRASA Puerto Rico Aqueduct and Sewer Authority
PO BOX 7066
SAN JUAN, PR 00916 - 7066
3149-1984 Reglamento de Normas de Diseño (Complementary Code)  

PSAI
Portable Sanitation Association International
2626 E. 82nd Street, Suite 175
Bloomington MN 55425
PSAI/ANSI Z4.3—16
Minimum Requirements for Nonsewered Waste-disposal Systems
TCNA
Tile Council of North America
100 Clemson Research Boulevard
Anderson SC 29625
TCNA/ANSI A118.10—99
Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic Tile and Dimension Stone Installation
UL
UL LLC
333 Pfingsten Road
Northbrook IL 60062-2096
399—2008
Drinking-Water Coolers—with revisions through October 2013
430—2009
Waste Disposers—with revisions through September 2015
508—99
Industrial Control Equipment—with revisions through October 2013
1795—2009
Hydromassage Bathtubs—with revisions through January 2015