Heads up: There are no amended sections in this chapter.
This annex contains normative material from an existing ASHRAE standard that is cited in this standard. This annex is not part of this standard; its inclusion is merely informative. It is included here to facilitate use of this standard.
Annex 1 contains extractions of the following material from ASHRAE Standard 169 in the following order:
ASHRAE Standard 169 Material
Table Annex1-1: Table B-1, U.S. Climate Zones by State and County
Figure Annex1-1: Figure B-1, Climate zones for United States counties.
Table Annex1-2: Table A-5, Canada Stations and Climate Zones
Table Annex1-3: Table A-6, International Stations and Climate Zones
Section Annex1-1: Section A3, Climate Zone Definitions
Table Annex1-4: Table A-3. Thermal Climate Zone Definitions
Figure Annex1-2: Figure A-1, Thermal climate zones as a function of heating and cooling degree-days.
Figure Annex1-3: Figure C-2, World climate zones map.
Section Annex1-2: Section 4, Climatic Design Data and Climate Zones
Informative Note
Section references that appear in this annex are references to sections or appendices in ANSI/ASHRAE Standard 169.
Table Annex 1-1 ASHRAE Standard 169-2013, Table B-1: U.S. Climate Zones by State and County
State/County Zone
Alabama (AL)
Zone 3A except...
Baldwin 2A
Coffee 2A
Covington 2A
Dale 2A
Escambia 2A
Geneva 2A
Henry 2A
Houston 2A
Mobile 2A
Alaska (AK)
Zone 7 except...
Ketchikan Gateway 5C
Prince of Wales-Outer Ketchikan 5C
Sitka 5C
Haines 6A
Juneau 6A
Kodiak Island 6A
Skagway-Hoonah-Angoon 6A
Wrangell-Petersburg 6A
Denali 8
Fairbanks North Star 8
Nome 8
North Slope 8
Northwest Arctic 8
Southeast Fairbanks 8
Wade Hampton 8
Yukon-Koyukuk 8
Arizona (AZ)
Zone 3B except...
La Paz 2B
Maricopa 2B
Pima 2B
Pinal 2B
Yuma 2B
Gila 4B
Yavapai 4B
Apache 5B
Coconino 5B
Navajo 5B
Arkansas (AR)
Zone 3A except...
Baxter 4A
Benton 4A
Boone 4A
Carroll 4A
Fulton 4A
Izard 4A
Madison 4A
Marion 4A
Newton 4A
Searcy 4A
Stone 4A
Washington 4A
California (CA)
Zone 3B except...
Imperial 2B
Alameda 3C
Marin 3C
Mendocino 3C
Monterey 3C
Napa 3C
San Benito 3C
San Francisco 3C
San Luis Obispo 3C
San Mateo 3C
Santa Barbara 3C
Santa Clara 3C
Santa Cruz 3C
Sonoma 3C
Ventura 3C
Amador 4B
Calaveras 4B
El Dorado 4B
Inyo 4B
Lake 4B
Mariposa 4B
Trinity 4B
Tuolumne 4B
Del Norte 4C
Humboldt 4C
Lassen 5B
Modoc 5B
Nevada 5B
Plumas 5B
Sierra 5B
Siskiyou 5B
Alpine 6B
Mono 6B
Colorado (CO)
Zone 5B except...
Baca 4B
Bent 4B
Las Animas 4B
Otero 4B
Prowers 4B
Alamosa 6B
Archuleta 6B
Chaffee 6B
Conejos 6B
Costilla 6B
Dolores 6B
Eagle 6B
Moffat 6B
Ouray 6B
Rio Blanco 6B
Saguache 6B
San Miguel 6B
Clear Creek 7
Grand 7
Gunnison 7
Hinsdale 7
Jackson 7
Lake 7
Mineral 7
Park 7
Pitkin 7
Rio Grande 7
Routt 7
San Juan 7
Summit 7
Connecticut (CT)
Zone 5A
Delaware (DE)
Zone 4A
District of Columbia (DC)
Zone 4A
Florida (FL)
Zone 2A except...
Broward 1A
Miami-Dade 1A
Monroe 1A
Palm Beach 1A
Georgia (GA)
Zone 3A except...
Appling 2A
Atkinson 2A
Bacon 2A
Baker 2A
Berrien 2A
Brantley 2A
Brooks 2A
Bryan 2A
Calhoun 2A
Camden 2A
Charlton 2A
Chatham 2A
Clinch 2A
Coffee 2A
Colquitt 2A
Cook 2A
Decatur 2A
Dougherty 2A
Early 2A
Echols 2A
Effingham 2A
Evans 2A
Glynn 2A
Grady 2A
Irwin 2A
Jeff Davis 2A
Lanier 2A
Liberty 2A
Long 2A
Lowndes 2A
McIntosh 2A
Miller 2A
Mitchell 2A
Pierce 2A
Seminole 2A
Tattnall 2A
Thomas 2A
Tift 2A
Toombs 2A
Ware 2A
Wayne 2A
Worth 2A
Hawaii (HI)
Zone 1A
Idaho (ID)
Zone 6B except...
Ada 5B
Benewah 5B
Canyon 5B
Cassia 5B
Clearwater 5B
Elmore 5B
Gem 5B
Gooding 5B
Idaho 5B
Jerome 5B
Kootenai 5B
Latah 5B
Lewis 5B
Lincoln 5B
Minidoka 5B
Nez Perce 5B
Owyhee 5B
Payette 5B
Power 5B
Shoshone 5B
Twin Falls 5B
Washington 5B
Illinois (IL)
Zone 5A except...
Alexander 4A
Bond 4A
Calhoun 4A
Christian 4A
Clark 4A
Clay 4A
Clinton 4A
Coles 4A
Crawford 4A
Cumberland 4A
Edwards 4A
Effingham 4A
Fayette 4A
Franklin 4A
Gallatin 4A
Greene 4A
Hamilton 4A
Hardin 4A
Jackson 4A
Jasper 4A
Jefferson 4A
Jersey 4A
Johnson 4A
Lawrence 4A
Macoupin 4A
Madison 4A
Marion 4A
Massac 4A
Monroe 4A
Montgomery 4A
Perry 4A
Pope 4A
Pulaski 4A
Randolph 4A
Richland 4A
Saline 4A
Shelby 4A
St. Clair 4A
Union 4A
Wabash 4A
Washington 4A
Wayne 4A
White 4A
Williamson 4A
Indiana (IN)
Zone 5A except...
Bartholomew 4A
Brown 4A
Clark 4A
Clay 4A
Crawford 4A
Daviess 4A
Dearborn 4A
Decatur 4A
Dubois 4A
Fayette 4A
Floyd 4A
Franklin 4A
Gibson 4A
Greene 4A
Harrison 4A
Hendricks 4A
Jackson 4A
Jefferson 4A
Jennings 4A
Johnson 4A
Knox 4A
Lawrence 4A
Marion 4A
Martin 4A
Monroe 4A
Morgan 4A
Ohio 4A
Orange 4A
Owen 4A
Perry 4A
Pike 4A
Posey 4A
Putnam 4A
Ripley 4A
Rush 4A
Scott 4A
Shelby 4A
Spencer 4A
Sullivan 4A
Switzerland 4A
Union 4A
Vanderburgh 4A
Vigo 4A
Warrick 4A
Washington 4A
Iowa (IA)
Zone 5A except...
Cerro Gordo 6A
Clay 6A
Dickinson 6A
Emmet 6A
Hancock 6A
Kossuth 6A
Lyon 6A
Mitchell 6A
O'Brien 6A
Osceola 6A
Palo Alto 6A
Sioux 6A
Winnebago 6A
Worth 6A
Kansas (KS)
Zone 4A except...
Cheyenne 5A
Decatur 5A
Gove 5A
Greeley 5A
Jewell 5A
Logan 5A
Norton 5A
Phillips 5A
Rawlins 5A
Republic 5A
Scott 5A
Sheridan 5A
Sherman 5A
Smith 5A
Thomas 5A
Wallace 5A
Wichita 5A
Kentucky (KY)
Zone 4A
Louisiana (LA)
Zone 2A except...
Bienville Parish 3A
Bossier Parish 3A
Caddo Parish 3A
Caldwell Parish 3A
Catahoula Parish 3A
Claiborne Parish 3A
Concordia Parish 3A
De Soto Parish 3A
East Carroll Parish 3A
Franklin Parish 3A
Grant Parish 3A
Jackson Parish 3A
La Salle Parish 3A
Lincoln Parish 3A
Madison Parish 3A
Morehouse Parish 3A
Natchitoches Parish 3A
Ouachita Parish 3A
Red River Parish 3A
Richland Parish 3A
Sabine Parish 3A
Tensas Parish 3A
Union Parish 3A
Vernon Parish 3A
Webster Parish 3A
West Carroll Parish 3A
Winn Parish 3A
Maine (ME)
Zone 6A except...
Aroostook 7
Maryland (MD)
Zone 4A except...
Allegany 5A
Garrett 5A
Massachusetts (MA)
Zone 5A
Michigan (MI)
Zone 5A except...
Alcona 6A
Alger 6A
Alpena 6A
Antrim 6A
Arenac 6A
Baraga 6A
Benzie 6A
Charlevoix 6A
Cheboygan 6A
Chippewa 6A
Clare 6A
Crawford 6A
Delta 6A
Dickinson 6A
Emmet 6A
Gladwin 6A
Gogebic 6A
Grand Traverse 6A
Houghton 6A
Iosco 6A
Iron 6A
Isabella 6A
Kalkaska 6A
Lake 6A
Leelanau 6A
Luce 6A
Mackinac 6A
Manistee 6A
Mason 6A
Mecosta 6A
Menominee 6A
Missaukee 6A
Montmorency 6A
Newaygo 6A
Oceana 6A
Ogemaw 6A
Ontonagon 6A
Osceola 6A
Oscoda 6A
Otsego 6A
Presque Isle 6A
Roscommon 6A
Schoolcraft 6A
Wexford 6A
Keweenaw 7
Marquette 7
Minnesota (MN)
Zone 6A except...
Fillmore 5A
Houston 5A
Winona 5A
Aitkin 7
Beltrami 7
Carlton 7
Cass 7
Clearwater 7
Cook 7
Crow Wing 7
Hubbard 7
Itasca 7
Kittson 7
Koochiching 7
Lake 7
Lake of the Woods 7
Mahnomen 7
Marshall 7
Norman 7
Pennington 7
Pine 7
Polk 7
Red Lake 7
Roseau 7
St. Louis 7
Wadena 7
Mississippi (MS)
Zone 3A except...
George 2A
Hancock 2A
Harrison 2A
Jackson 2A
Pearl River 2A
Stone 2A
Missouri (MO)
Zone 4A except...
Dunklin 3A
Pemiscot 3A
Adair 5A
Andrew 5A
Atchison 5A
Clark 5A
Daviess 5A
DeKalb 5A
Gentry 5A
Grundy 5A
Harrison 5A
Holt 5A
Knox 5A
Lewis 5A
Linn 5A
Livingston 5A
Macon 5A
Marion 5A
Mercer 5A
Nodaway 5A
Pike 5A
Putnam 5A
Ralls 5A
Schuyler 5A
Scotland 5A
Shelby 5A
Sullivan 5A
Worth 5A
Montana (MT)
Zone 6B
Nebraska (NE)
Zone 5A
Nevada (NV)
Zone 5B except...
Clark 3B
Carson City 4B
Douglas 4B
Esmeralda 4B
Lincoln 4B
Lyon 4B
Mineral 4B
Nye 4B
New Hampshire (NH)
Zone 6A except...
Hillsborough 5A
Merrimack 5A
Rockingham 5A
Strafford 5A
New Jersey (NJ)
Zone 4A except...
Bergen 5A
Hunterdon 5A
Morris 5A
Passaic 5A
Somerset 5A
Sussex 5A
Warren 5A
New Mexico (NM)
Zone 5B except...
Chaves 3B
Dona Ana 3B
Eddy 3B
Hidalgo 3B
Lea 3B
Luna 3B
Otero 3B
Sierra 3B
Bernalillo 4B
Catron 4B
Curry 4B
DeBaca 4B
Grant 4B
Guadalupe 4B
Lincoln 4B
Quay 4B
Roosevelt 4B
Socorro 4B
Union 4B
Valencia 4B
New York (NY)
Zone 5A except...
Bronx 4A
Kings 4A
Nassau 4A
New York 4A
Queens 4A
Richmond 4A
Suffolk 4A
Chenango 6A
Clinton 6A
Delaware 6A
Essex 6A
Franklin 6A
Fulton 6A
Hamilton 6A
Herkimer 6A
Jefferson 6A
Lewis 6A
Madison 6A
Montgomery 6A
Oneida 6A
Otsego 6A
St. Lawrence 6A
Sullivan 6A
Ulster 6A
Warren 6A
North Carolina (NC)
Zone 3A except...
Alleghany 5A
Ashe 5A
Avery 5A
Buncombe 4A
Burke 4A
Caldwell 4A
Graham 4A
Haywood 4A
Henderson 4A
Jackson 4A
Macon 4A
Madison 4A
McDowell 4A
Mitchell 4A
Stokes 4A
Surry 4A
Swain 4A
Transylvania 4A
Watauga 5A
Wilkes 5A
Yadkin 4A
Yancy 5A
North Dakota (ND)
Zone 6A except...
Benson 7
Bottineau 7
Burke 7
Cavalier 7
Divide 7
Grand Forks 7
McHenry 7
Nelson 7
Pembina 7
Pierce 7
Ramsey 7
Renville 7
Rolette 7
Towner 7
Walsh 7
Ward 7
Ohio (OH)
Zone 5A except...
Adams 4A
Athens 4A
Brown 4A
Butler 4A
Clermont 4A
Clinton 4A
Fayette 4A
Franklin 4A
Gallia 4A
Greene 4A
Hamilton 4A
Highland 4A
Hocking 4A
Jackson 4A
Lawrence 4A
Madison 4A
Meigs 4A
Pickaway 4A
Pike 4A
Ross 4A
Scioto 4A
Vinton 4A
Warren 4A
Washington 4A
Oklahoma (OK)
Zone 3A except...
Alfalfa 4A
Craig 4A
Delaware 4A
Ellis 4A
Garfield 4A
Grant 4A
Harper 4A
Kay 4A
Major 4A
Nowata 4A
Osage 4A
Ottawa 4A
Washington 4A
Woods 4A
Woodward 4A
Beaver 4B
Cimarron 4B
Texas 4B
Oregon (OR)
Zone 4C except...
Baker 5B
Crook 5B
Deschutes 5B
Gilliam 5B
Grant 5B
Harney 5B
Hood River 5B
Jefferson 5B
Klamath 5B
Lake 5B
Malheur 5B
Morrow 5B
Sherman 5B
Umatilla 5B
Union 5B
Wallowa 5B
Wasco 5B
Wheeler 5B
Pennsylvania (PA)
Zone 5A except...
Adams 4A
Berks 4A
Bucks 4A
Chester 4A
Cumberland 4A
Dauphin 4A
Delaware 4A
Franklin 4A
Lancaster 4A
Lebanon 4A
Montgomery 4A
Perry 4A
Philadelphia 4A
York 4A
Rhode Island (RH)
Zone 5A
South Carolina (SC)
Zone 3A except...
Beaufort 2A
Jasper 2A
South Dakota (SD)
Zone 6A except...
Bennett 5A
Bon Homme 5A
Brule 5A
Charles Mix 5A
Clay 5A
Douglas 5A
Gregory 5A
Haakon 5A
Hutchinson 5A
Jackson 5A
Jones 5A
Lyman 5A
Mellette 5A
Stanley 5A
Todd 5A
Tripp 5A
Union 5A
Yankton 5A
Tennessee (TN)
Zone 4A except...
Bedford 3A
Chester 3A
Coffee 3A
Crockett 3A
Davidson 3A
Decatur 3A
Dyer 3A
Fayette 3A
Franklin 3A
Gibson 3A
Giles 3A
Grundy 3A
Hamilton 3A
Hardeman 3A
Hardin 3A
Haywood 3A
Henderson 3A
Hickman 3A
Lauderdale 3A
Lawrence 3A
Lewis 3A
Lincoln 3A
Madison 3A
Marion 3A
Marshall 3A
Maury 3A
McNairy 3A
Moore 3A
Perry 3A
Rutherford 3A
Shelby 3A
Tipton 3A
Wayne 3A
Williamson 3A
Texas (TX)
Zone 3A except...
Cameron 1A
Hidalgo 1A
Willacy 1A
Anderson 2A
Angelina 2A
Aransas 2A
Atascosa 2A
Austin 2A
Bastrop 2A
Bee 2A
Bell 2A
Bexar 2A
Bosque 2A
Brazoria 2A
Brazos 2A
Brooks 2A
Burleson 2A
Caldwell 2A
Calhoun 2A
Chambers 2A
Cherokee 2A
Colorado 2A
Comal 2A
Coryell 2A
Dallas 2A
DeWitt 2A
Duval 2A
Ellis 2A
Falls 2A
Fayette 2A
Fort Bend 2A
Freestone 2A
Galveston 2A
Goliad 2A
Gonzales 2A
Grimes 2A
Guadalupe 2A
Hardin 2A
Harris 2A
Hays 2A
Hill 2A
Houston 2A
Jackson 2A
Jasper 2A
Jefferson 2A
Jim Hogg 2A
Jim Wells 2A
Johnson 2A
Karnes 2A
Kenedy 2A
Kleberg 2A
Lavaca 2A
Lee 2A
Leon 2A
Liberty 2A
Limestone 2A
Live Oak 2A
Madison 2A
Matagorda 2A
McLennan 2A
McMullen 2A
Milam 2A
Montgomery 2A
Navarro 2A
Newton 2A
Nueces 2A
Orange 2A
Polk 2A
Refugio 2A
Robertson 2A
San Jacinto 2A
San Patricio 2A
Starr 2A
Tarrant 2A
Travis 2A
Trinity 2A
Tyler 2A
Victoria 2A
Walker 2A
Waller 2A
Washington 2A
Wharton 2A
Williamson 2A
Wilson 2A
Bandera 2B
Dimmit 2B
Edwards 2B
Frio 2B
Kinney 2B
La Salle 2B
Maverick 2B
Medina 2B
Real 2B
Uvalde 2B
Val Verde 2B
Webb 2B
Zapata 2B
Zavala 2B
Andrews 3B
Baylor 3B
Borden 3B
Brewster 3B
Callahan 3B
Childress 3B
Coke 3B
Coleman 3B
Collingsworth 3B
Concho 3B
Cottle 3B
Crane 3B
Crockett 3B
Crosby 3B
Culberson 3B
Dawson 3B
Dickens 3B
Ector 3B
El Paso 3B
Fisher 3B
Foard 3B
Gaines 3B
Garza 3B
Glasscock 3B
Hall 3B
Hardeman 3B
Haskell 3B
Hemphill 3B
Howard 3B
Hudspeth 3B
Irion 3B
Jeff Davis 3B
Jones 3B
Kent 3B
Kerr 3B
Kimble 3B
King 3B
Knox 3B
Loving 3B
Lubbock 3B
Lynn 3B
Martin 3B
Mason 3B
McCulloch 3B
Menard 3B
Midland 3B
Mitchell 3B
Motley 3B
Nolan 3B
Pecos 3B
Presidio 3B
Reagan 3B
Reeves 3B
Runnels 3B
Schleicher 3B
Scurry 3B
Shackelford 3B
Sterling 3B
Stonewall 3B
Sutton 3B
Taylor 3B
Terrell 3B
Terry 3B
Throckmorton 3B
Tom Green 3B
Upton 3B
Ward 3B
Wheeler 3B
Wilbarger 3B
Winkler 3B
Armstrong 4B
Bailey 4B
Briscoe 4B
Carson 4B
Castro 4B
Cochran 4B
Dallam 4B
Deaf Smith 4B
Donley 4B
Floyd 4B
Gray 4B
Hale 4B
Hansford 4B
Hartley 4B
Hockley 4B
Hutchinson 4B
Lamb 4B
Lipscomb 4B
Moore 4B
Ochiltree 4B
Oldham 4B
Parmer 4B
Potter 4B
Randall 4B
Roberts 4B
Sherman 4B
Swisher 4B
Yoakum 4B
Utah (UT)
Zone 5B except...
Washington 3B
Daggett 6B
Duchesne 6B
Morgan 6B
Rich 6B
Summit 6B
Uintah 6B
Wasatch 6B
Vermont (VT)
Zone 6A
Virginia (VA)
Zone 4A except...
Alleghany 5A
Bath 5A
Brunswick 3A
Chesapeake city 3A
Clifton Forge city 5A
Covington city 5A
Emporia city 3A
Franklin city 3A
Greensville 3A
Halifax 3A
Hampton city 3A
Highland 5A
Isle of Wight 3A
Mecklenburg 3A
Newport News city 3A
Norfolk city 3A
Pittsylvania 3A
Portsmouth city 3A
South Boston 3A
Southampton 3A
Suffolk city 3A
Surry 3A
Sussex 3A
Virginia Beach city 3A
Washington (WA)
Zone 5B except...
Clark 4C
Cowlitz 4C
Grays Harbor 4C
Jefferson 4C
King 4C
Lewis 4C
Mason 4C
Pacific 4C
Pierce 4C
Skagit 4C
Snohomish 4C
Thurston 4C
Wahkiakum 4C
Whatcom 4C
Clallam 5C
Island 5C
Kitsap 5C
San Juan 5C
Ferry 6B
Pend Oreille 6B
Stevens 6B
West Virginia (WV)
Zone 5A except...
Berkeley 4A
Boone 4A
Braxton 4A
Cabell 4A
Calhoun 4A
Clay 4A
Doddridge 4A
Fayette 4A
Gilmer 4A
Greenbrier 4A
Jackson 4A
Jefferson 4A
Kanawha 4A
Lewis 4A
Lincoln 4A
Logan 4A
Mason 4A
McDowell 4A
Mercer 4A
Mingo 4A
Monroe 4A
Morgan 4A
Nicholas 4A
Pleasants 4A
Putnam 4A
Raleigh 4A
Ritchie 4A
Roane 4A
Summers 4A
Tyler 4A
Upshur 4A
Wayne 4A
Webster 4A
Wirt 4A
Wood 4A
Wyoming 4A
Wisconsin (WI)
Zone 6A except...
Adams 5A
Calumet 5A
Columbia 5A
Crawford 5A
Dane 5A
Dodge 5A
Fond du Lac 5A
Grant 5A
Green 5A
Green Lake 5A
Iowa 5A
Jefferson 5A
Juneau 5A
Kenosha 5A
La Crosse 5A
Lafayette 5A
Milwaukee 5A
Monroe 5A
Outagamie 5A
Ozaukee 5A
Racine 5A
Richland 5A
Rock 5A
Sauk 5A
Vernon 5A
Walworth 5A
Washington 5A
Waukesha 5A
Waushara 5A
Winnebago 5A
Wyoming (WY)
Zone 6B except...
Goshen 5B
Laramie 5B
Platte 5B
Lincoln 7
Sublette 7
Teton 7
Commonwealth/Municipality Zone
Puerto Rico (PR)
Zone 1A except...
Barraquitas 2B
Cayey 2B
Other Zone
Pacific Islands (PI)
Zone 1A except...
Midway Sand Island 2A
Virgin Islands (VI)
Zone 1A
Figure Annex1-1 ASHRAE Standard 169-2013, Figure B-1: Climate zones for United States counties.
Table Annex1-2 ASHRAE Standard 169-2013, Table A-5: Canada Stations and Climate Zones
Province/LOCATION WMO# Lat Long CZ Precipitation
mm in.
Alberta (AB)
BANFF CS 711220 51.19 —115.55 7 487 19
BOW ISLAND 712310 49.73 —111.45 6A 374 15
BOW VALLEY 712320 51.08 —115.07 7 584 23
BRETON PLOTS 712330 53.09 —114.44 7 460 18
BROOKS 714570 50.55 —111.85 6B 318 13
CALGARY INT'L A 718770 51.11 —114.02 7 425 17
CAMROSE 712540 53.03 —112.81 7 499 20
CARDSTON 711530 49.20 —113.29 6A 505 20
CLARESHOLM 712340 50.00 —113.64 6A 433 17
COLD LAKE A 711200 54.42 —110.28 7 464 18
COP UPPER 712350 51.08 —114.22 7 451 18
CORONATION (AUT) 718730 52.08 —111.45 7 405 16
CROWSNEST 712360 49.63 —114.48 7 664 26
DRUMHELLER EAST 712370 51.43 —112.67 7 390 15
EDMONTON CITY CENTRE A 718790 53.57 —113.52 7 481 19
EDMONTON INT'L A 711230 53.32 —113.58 7 493 19
EDMONTON NAMAO A 711210 53.67 —113.47 7 457 18
EDSON A 718810 53.60 —116.48 7 597 24
ELK ISLAND NAT PARK 712380 53.68 —112.87 7 442 17
ESTHER 1 712400 51.67 —110.21 7 323 13
FORT CHIPEWYAN A 719330 58.77 —111.12 8 417 16
FORT MCMURRAY A 719320 56.65 —111.22 7 476 19
GARDEN RIVER 712530 58.71 —113.87 7 385 15
GRANDE PRAIRIE A 719400 55.18 —118.88 7 477 19
HIGH LEVEL A 710660 58.62 —117.16 8 441 17
HIGHVALE 712410 53.45 —114.47 7 458 18
JASPER 718880 52.88 —118.07 7 415 16
JASPER WARDEN 714860 52.93 —118.03 7 415 16
LAC LA BICHE (AUT) 729310 54.77 —112.02 7 457 18
LACOMBE CDA 2 712420 52.45 —113.76 7 454 18
LETHBRIDGE A 718740 49.63 —112.80 6A 425 17
LETHBRIDGE CDA 712430 49.70 —112.78 6A 425 17
LLOYDMINSTER A 718710 53.31 —110.07 7 426 17
MEDICINE HAT A 718720 50.02 —110.72 6B 347 14
MILDRED LAKE 712550 57.04 —111.56 7 345 14
MILK RIVER 712440 49.13 —112.05 6B 364 14
NAKISKA RIDGETOP 712450 50.94 —115.19 8 605 24
ONEFOUR CDA 711160 49.12 —110.47 6A 347 14
PEACE RIVER A 710680 56.23 —117.45 7 412 16
PINCHER CREEK (AUT) 718750 49.52 —113.98 6A 484 19
RED DEER A 718780 52.18 —113.89 7 473 19
RED EARTH 712460 56.55 —115.28 7 430 17
ROCKY MTN HOUSE (AUT) 719280 52.42 —114.91 7 522 21
SLAVE LAKE A 710690 55.28 —114.78 7 525 21
SPRINGBANK A 718600 51.10 —114.37 7 491 19
STAVELY AAFC 715550 50.18 —113.88 6A 472 19
SUNDRE A 712480 51.78 —114.68 7 464 18
THREE HILLS 712490 51.83 —113.21 7 407 16
VAUXHALL CDA CS 712510 50.05 —112.13 6B 351 14
VEGREVILLE 714580 53.51 —112.10 7 375 15
WAINWRIGHT CFB AIRFIELD 21 711180 52.83 —111.10 7 431 17
WATERTON PARK GATE 711540 49.13 —113.81 6A 551 22
WHITECOURT A 719300 54.14 —115.79 7 594 23
British Columbia (BC)
ABBOTSFORD A 711080 49.03 —122.36 4C 1168 46
AGASSIZ CS 711130 49.25 —121.77 4C 1769 70
ALERT BAY 711100 50.58 —126.93 5C 1668 66
AMPHITRITE POINT 711120 48.92 —125.54 5C 3212 126
BALLENAS ISLAND 717690 49.35 —124.16 4C 981 39
BLUE RIVER CS 718830 52.13 —119.29 6A 1032 41
BONILLA ISLAND (AUT) 714840 53.50 —130.63 5C 2169 85
BURNS LAKE DECKER LAKE 719520 54.38 —125.96 7 503 20
CAPE SCOTT 711110 50.78 —128.43 5C 2296 90
CAPE ST JAMES CS 711070 51.94 —131.02 5C 1599 63
CATHEDRAL POINT (AUT) 714820 52.19 —127.47 5C 3439 135
CLINTON (AUT) 714740 51.14 —121.50 7 392 15
COMOX A 718930 49.72 —124.90 5C 1340 53
CRANBROOK A 718800 49.61 —115.78 6A 408 16
CRESTON CAMPBELL SCIENTIFIC 717700 49.08 —116.50 5A 511 20
CUMSHEWA ISLAND 717710 53.03 —131.60 5C 2374 93
DEASE LAKE 719580 58.43 —130.01 7 452 18
DISCOVERY ISLAND 710310 48.42 —123.23 4C 646 25
ENTRANCE ISLAND CS 717720 49.22 —123.80 4C 1135 45
ESQUIMALT HARBOUR 717980 48.43 —123.44 4C 646 25
ESTEVAN POINT CS 718940 49.38 —126.54 5C 3276 129
FORT NELSON A 719450 58.84 —122.60 7 469 18
FORT ST JOHN A 719430 56.24 —120.74 7 477 19
GREY ISLET (AUT) 714760 54.58 —130.70 5A 2302 91
HERBERT ISLAND (AUT) 714850 50.94 —127.64 5C 2155 85
HOLLAND ROCK 712190 54.17 —130.36 5C 2353 93
HOPE 711140 49.37 —121.48 5C 1760 69
HOWE SOUND - PAM ROCKS 712110 49.49 —123.30 4C 1535 60
KAMLOOPS A 718870 50.70 —120.44 5B 286 11
KELOWNA A 712030 49.96 —119.38 5A 471 19
KINDAKUN ROCKS (AUT) 714720 53.32 —132.77 5C 1981 78
LANGARA 718990 54.26 —133.06 5C 1952 77
LILLOOET 719990 50.68 —121.93 5A 392 15
LUCY ISLAND LIGHTSTATION 712200 54.30 —130.61 5C 2317 91
LYTTON 718910 50.22 —121.58 5C 455 18
MACKENZIE A 719440 55.31 —123.14 7 687 27
MALAHAT 717740 48.57 —123.53 5C 1095 43
NAKUSP CS 712160 50.27 —117.81 5A 832 33
NELSON CS 717760 49.49 —117.31 5A 741 29
OSOYOOS CS 712150 49.03 —119.44 5B 319 13
PEMBERTON AIRPORT CS 717770 50.30 —122.74 5C 850 33
PENTICTON A 718890 49.46 —119.60 5B 303 12
PITT MEADOWS CS 717750 49.21 —122.69 4C 1483 58
POINT ATKINSON 710370 49.33 —123.26 4C 1535 60
PORT ALBERNI (AUT) 714750 49.32 —124.93 5C 1636 64
PORT HARDY A 711090 50.68 —127.37 5C 1917 75
PRINCE GEORGE A 718960 53.89 —122.68 7 658 26
PRINCE RUPERT A 718980 54.29 —130.44 5C 2690 106
PRINCETON CS 710320 49.47 —120.51 6A 369 15
PUNTZI MOUNTAIN (AUT) 710500 52.11 —124.14 7 394 16
QUESNEL A 711030 53.03 —122.51 6A 554 22
REVELSTOKE A 718820 50.96 —118.18 6A 1018 40
ROSE SPIT (AUT) 714770 54.16 —131.66 5A 1434 56
SALMON ARM CS 712180 50.70 —119.29 5A 458 18
SANDHEADS CS 712090 49.11 —123.30 4C 1082 43
SANDSPIT A 711010 53.25 —131.81 5C 1323 52
SARTINE ISLAND (AUT) 714780 50.82 —128.91 5C 1920 76
SHERINGHAM POINT 717800 48.38 —123.92 5C 1497 59
SISTERS ISLAND 717810 49.49 —124.43 4C 1103 43
SMITHERS A 719500 54.82 —127.18 7 539 21
SOLANDER ISLAND (AUT) 714790 50.11 —127.94 5C 2375 94
SPARWOOD CS 717820 49.75 —114.89 7 1021 40
SQUAMISH 712070 49.78 —123.16 5C 2294 90
SUMMERLAND CS 717680 49.56 —119.64 5B 321 13
TERRACE A 719510 54.47 —128.58 6A 1378 54
VANCOUVER HARBOUR CS 712010 49.30 —123.12 4C 1517 60
VANCOUVER INT'L A 718920 49.20 —123.18 4C 1209 48
VERNON CS 711150 50.22 —119.19 5A 453 18
VICTORIA GONZALES CS 712000 48.41 —123.33 4C 646 25
VICTORIA HARTLAND CS 710380 48.53 —123.46 4C 948 37
VICTORIA INT'L A 717990 48.65 —123.43 5C 948 37
VICTORIA MARINE 712020 48.37 —123.75 5C 1265 50
VICTORIA UNIVERSITY CS 717830 48.46 —123.30 4C 646 25
WEST VANCOUVER AUT 717840 49.35 —123.19 4C 1517 60
WHITE ROCK CAMPBELL SCIENTIFI 717850 49.02 —122.78 4C 1049 41
WILLIAMS LAKE A 711040 52.18 —122.05 7 451 18
YOHO PARK 717860 51.44 —116.34 7 541 21
Manitoba (MB)
BERENS RIVER CS 711580 52.36 —97.02 7 475 19
BRANDON A 711400 49.91 —99.95 7 471 19
CARBERRY CS 711700 49.91 —99.36 7 523 21
CARMAN U OF M CS 711470 49.50 —98.03 7 527 21
CHURCHILL A 719130 58.74 —94.06 8 449 18
DAUPHIN A 718550 51.10 —100.05 7 513 20
DELTA MARSH CS 715630 50.18 —98.38 7 530 21
EMERSON AUT 715600 49.00 —97.24 7 488 19
FISHER BRANCH (AUT) 714420 51.08 —97.55 7 562 22
GEORGE ISLAND (AUT) 714450 52.82 —97.62 7 449 18
GILLAM A 719120 56.36 —94.71 8 518 20
GIMLI INDUSTRIAL PARK 718560 50.63 —97.05 7 500 20
GRAND RAPIDS (AUT) 718580 53.19 —99.27 7 485 19
GRETNA (AUT) 714410 49.03 —97.56 7 512 20
HUNTERS POINT MARINE 711420 53.03 —100.93 7 462 18
ISLAND LAKE A 711450 53.85 —94.65 7 581 23
LYNN LAKE A 710780 56.86 —101.08 8 535 21
MELITA 714470 49.28 —100.99 7 446 18
NORWAY HOUSE A 711410 53.95 —97.85 7 530 21
OAKPOINT MARINE 711440 50.50 —98.04 7 532 21
PILOT MOUND (AUT) 711480 49.19 —98.90 7 487 19
PINAWA 714480 50.18 —96.06 7 435 17
PORTAGE SOUTHPORT A 718510 49.90 —98.27 7 515 20
ROBLIN 715530 51.18 —101.36 7 466 18
SHOAL LAKE CS 711500 50.45 —100.60 7 504 20
SPRAGUE 714490 49.02 —95.60 7 622 24
SWAN RIVER RCS 714430 52.12 —101.23 7 468 18
THE PAS A 718670 53.97 —101.10 7 470 18
THOMPSON A 710790 55.80 —97.86 8 520 20
VICTORIA BEACH (AUT) 715520 50.70 —96.57 7 489 19
WASAGAMING 714440 50.66 —99.94 7 528 21
WILSON CREEK WEIR CS 711490 50.71 —99.53 7 536 21
WINNIPEG RICHARDSON INT'L A 718520 49.92 —97.23 7 523 21
New Brunswick (NB)
BAS CARAQUET 715980 47.80 —64.83 6A 1049 41
CHARLO A 717110 47.98 —66.33 7 1112 44
FREDERICTON A 717000 45.87 —66.53 6A 1151 45
MIRAMICHI A 717170 47.01 —65.47 7 1090 43
MIRAMICHI RCS 717440 47.01 —65.46 6A 1090 43
MISCOU ISLAND (AUT) 717190 48.01 —64.49 7 1037 41
MONCTON A 717050 46.10 —64.69 6A 1290 51
POINT ESCUMINAC (AUT) 714140 47.07 —64.80 6A 1133 45
POINT LEPREAU CS 716990 45.07 —66.45 6A 1253 49
SAINT JOHN A 716090 45.32 —65.89 6A 1317 52
ST LEONARD CS 710190 47.16 —67.83 7 997 39
ST STEPHEN (AUT) 716070 45.22 —67.25 6A 1149 45
Newfoundland And Labrador (NL)
ARGENTIA (AUT) 718070 47.29 —53.99 6A 1304 51
BADGER (AUT) 714000 48.97 —56.07 7 1072 42
BONAVISTA 711960 48.67 —53.11 6A 1068 42
BURGEO 2 711940 47.62 —57.62 6A 1818 72
CAPE KAKKIVIAK 711760 59.98 —64.16 8 376 15
CAPE RACE (AUT) 718000 46.66 —53.08 6A 1378 54
CARTWRIGHT 718180 53.71 —57.04 7 1060 42
CHURCHILL FALLS 711820 53.56 —64.09 8 999 39
COMFORT COVE 711930 49.27 —54.88 7 1213 48
CORNER BROOK 719730 48.93 —57.92 6A 1222 48
DANIELS HARBOUR 711850 50.24 —57.58 7 1164 46
DEER LAKE A 718090 49.22 —57.40 7 1105 44
ENGLEE (AUT) 714170 50.72 —56.11 7 1022 40
FEROLLE POINT (AUT) 714060 51.02 —57.10 7 1185 47
GANDER INT'L A 718030 48.95 —54.58 7 1255 49
GOOSE A 718160 53.32 —60.42 7 996 39
GRATES COVE 713360 48.17 —52.94 6A 1408 55
HOPEDALE (AUT) 719000 55.45 —60.22 8 884 35
LA SCIE 713370 49.92 —55.67 7 1293 51
MARTICOT ISLAND 716920 47.33 —54.59 6A 1395 55
POOLS ISLAND 719310 49.11 —53.58 6A 1015 40
PORT AUX BASQUES 711970 47.57 —59.15 7 1563 62
SAGLEK 713350 58.33 —62.59 8 836 33
SAGONA ISLAND 714080 47.37 —55.79 6A 1574 62
ST ANTHONY 715580 51.38 —56.10 7 1183 47
ST JOHN'S A 718010 47.62 —52.74 6A 1547 61
ST LAWRENCE 718020 46.92 —55.38 6A 1603 63
STEPHENVILLE A 718150 48.53 —58.55 6A 1364 54
TWILLINGATE (AUT) 714020 49.68 —54.80 7 1015 40
WABUSH LAKE A 718250 52.93 —66.87 8 936 37
Nova Scotia (NS)
AMHERST (AUT) 714100 45.85 —64.27 6A 1212 48
BACCARO POINT 716910 43.45 —65.47 6A 1258 50
BEAVER ISLAND (AUT) 714030 44.82 —62.33 6A 1472 58
BRIER ISLAND 719880 44.29 —66.35 6A 1202 47
CARIBOU POINT (AUT) 714150 45.77 —62.68 6A 1063 42
GRAND ETANG 715970 46.55 —61.05 6A 1202 47
GREENWOOD A 713970 44.98 —64.92 6A 1253 49
HALIFAX STANFIELD INT'L A 713950 44.88 —63.52 6A 1532 60
HART ISLAND (AUT) 714190 45.35 —60.98 6A 1464 58
KEJIMKUJIK 1 715990 44.43 —65.20 6A 1438 57
SABLE ISLAND 716000 43.93 —60.01 5A 1392 55
SHEARWATER A 716010 44.63 —63.50 6A 1414 56
SHEARWATER JETTY CAN35X 44.63 —63.52 5A 1414 56
ST PAUL ISLAND (AUT) 714180 47.23 —60.14 6A 1391 55
SYDNEY A 717070 46.17 —60.05 6A 1523 60
WESTERN HEAD 714110 43.99 —64.66 6A 1405 55
YARMOUTH A 716030 43.83 —66.09 6A 1305 51
Northwest Territories (NT)
AULAVIK NATIONAL PARK 719740 74.14 —119.99 8 116 5
CAPE PARRY A 719480 70.17 —124.72 8 154 6
COLVILLE LAKE 710550 67.04 —126.08 8 317 12
FORT GOOD HOPE CS 714910 66.24 —128.64 8 317 12
FORT LIARD 714970 60.23 —123.47 8 435 17
FORT PROVIDENCE 710870 61.32 —117.60 8 266 10
FORT RELIANCE 710730 62.72 —109.17 8 283 11
FORT SIMPSON A 719460 61.76 —121.24 8 376 15
FORT SMITH A 719340 60.02 —111.96 8 373 15
HANBURY RIVER 719630 63.60 —105.13 8 275 11
HAY RIVER A 719350 60.84 —115.78 8 373 15
INNER WHALEBACKS 711620 61.92 —113.73 8 283 11
INUVIK A 719570 68.30 —133.48 8 267 11
LAC LA MARTRE 711630 63.13 —117.25 8 265 10
LINDBURG LANDING 716820 61.12 —122.85 8 399 16
LITTLE CHICAGO 711640 67.18 —130.23 8 310 12
LIVERPOOL BAY 719600 69.60 —130.91 8 130 5
MOULD BAY A 710720 76.23 —119.33 8 114 4
NICHOLSON PENINSULA 719560 69.93 —128.97 8 107 4
NORMAN WELLS A 710430 65.28 —126.80 8 336 13
PELLY ISLAND 715020 69.63 —135.44 8 194 8
RAE LAKES 711650 64.11 —117.33 8 260 10
SACHS HARBOUR CLIMATE 714670 71.99 —125.25 8 134 5
TROUT LAKE 711660 60.44 —121.24 8 405 16
TUKTOYAKTUK 719850 69.43 —133.02 8 136 5
YELLOWKNIFE A 719360 62.46 —114.44 8 287 11
YOHIN 710200 61.24 —123.74 8 413 16
Nunavut (NU)
ALERT 710820 82.52 —62.28 8 172 7
BAKER LAKE A 719260 64.30 —96.08 8 272 11
BREVOORT ISLAND 710970 63.34 —64.15 8 624 25
BYRON BAY A 719290 68.75 —109.07 8 121 5
CAMBRIDGE BAY A 719250 69.11 —105.14 8 149 6
CAPE DORSET A 719100 64.23 —76.53 8 402 16
CAPE DYER 710940 66.65 —61.38 8 627 25
CAPE HOOPER 710930 68.47 —66.82 8 265 10
CAPE MERCY 719750 64.96 —63.58 8 467 18
CAPE PEEL WEST 710640 69.04 —107.82 8 133 5
CLINTON POINT 710530 69.58 —120.80 8 161 6
CLYDE A 710900 70.49 —68.52 8 239 9
CORAL HARBOUR A 719150 64.19 —83.36 8 299 12
CROKER RIVER 710590 69.28 —119.22 8 183 7
DEWAR LAKES 710920 68.65 —71.17 8 248 10
ENNADAI LAKE (AUT) 719230 61.13 —100.88 8 326 13
EUREKA 719170 79.98 —85.93 8 76 3
FOX FIVE 710960 67.54 —63.79 8 289 11
GLADMAN POINT A 719270 68.67 —97.80 8 125 5
HALL BEACH A 710810 68.78 —81.24 8 235 9
HAT ISLAND 710840 68.32 —100.09 8 204 8
IQALUIT A 719090 63.75 —68.55 8 422 17
JENNY LIND ISLAND A 710710 68.65 —101.73 8 116 5
KUGLUKTUK A 719380 67.82 —115.14 8 263 10
LADY FRANKLIN POINT A 719370 68.50 —113.22 8 121 5
LONGSTAFF BLUFF 710910 68.90 —75.14 8 212 8
MACKAR INLET 710800 68.30 —85.67 8 187 7
PANGNIRTUNG 718260 66.15 —65.72 8 427 17
PELLY BAY 719190 68.43 —89.72 8 240 9
POND INLET A 710950 72.68 —77.98 8 196 8
RANKIN INLET A 710830 62.82 —92.12 8 324 13
RESOLUTE CARS 719240 74.72 —94.99 8 152 6
RESOLUTION ISLAND 719720 61.60 —64.63 8 364 14
ROBERTSON LAKE (AUT) 714900 65.10 —102.43 8 256 10
SHEPHERD BAY A 719110 68.82 —93.43 8 155 6
Ontario (ON)
ARMSTRONG (AUT) 718410 50.29 —88.91 7 737 29
ATIKOKAN (AUT) 717470 48.76 —91.63 7 798 31
BANCROFT AUTO 712940 45.07 —77.88 7 873 34
BEAUSOLEIL 712720 44.85 —79.87 6A 934 37
BELLE RIVER 712730 42.30 —82.70 5A 804 32
BIG TROUT LAKE 718480 53.83 —89.87 8 582 23
BIG TROUT LAKE READAC 718440 53.82 —89.90 8 582 23
BURLINGTON PIERS (AUT) 714370 43.30 —79.80 5A 827 33
COBOURG (AUT) 714310 43.95 —78.17 6A 808 32
COLLINGWOOD 712700 44.50 —80.22 6A 766 30
COVE ISLAND (AUT) 714390 45.33 —81.73 6A 869 34
EARLTON A 717350 47.70 —79.85 7 801 32
ERIEAU (AUT) 714650 42.25 —81.90 5A 797 31
GERALDTON A 718340 49.78 —86.93 7 774 30
GODERICH 712610 43.77 —81.72 5A 981 39
GORE BAY A 717330 45.88 —82.57 6A 834 33
GREAT DUCK ISLAND (AUT) 714620 45.63 —82.95 6A 809 32
GRENADIER ISLAND 712810 44.42 —75.85 6A 947 37
KAPUSKASING A 718310 49.41 —82.47 7 891 35
KENORA A 718500 49.79 —94.37 7 674 27
KILLARNEY (AUT) 714600 45.97 —81.48 6A 839 33
LAGOON CITY 712820 44.55 —79.22 6A 929 37
LANSDOWNE HOUSE (AUT) 718460 52.20 —87.94 7 719 28
LONDON INT'L AIRPORT 716230 43.03 —81.15 5A 981 39
LONG POINT (AUT) 714640 42.57 —80.05 5A 948 37
MOOSONEE A 718360 51.29 —80.61 7 722 28
MOUNT FOREST (AUT) 716310 43.98 —80.75 6A 969 38
NAGAGAMI (AUT) 718320 49.75 —84.16 7 793 31
NORTH BAY A 717310 46.36 —79.42 7 1012 40
OTTAWA MACDONALD-CARTIER INT' 716280 45.32 —75.67 6A 922 36
PEAWANUCK (AUT) 714340 54.98 —85.43 8 602 24
PETAWAWA A 716250 45.95 —77.32 7 851 34
PETERBOROUGH A 716290 44.23 —78.37 6A 843 33
PICKLE LAKE (AUT) 718350 51.45 —90.22 7 726 29
POINT PETRE (AUT) 714300 43.83 —77.15 6A 965 38
PORT COLBORNE (AUT) 714630 42.87 —79.25 5A 986 39
PORT WELLER (AUT) 714320 43.25 —79.22 5A 890 35
PUKASKWA (AUT) 717500 48.59 —86.29 7 865 34
RED LAKE A 718540 51.07 —93.79 7 668 26
ROYAL ISLAND (AUT) CAN21X 49.47 —94.76 7 613 24
SAULT STE MARIE A 712600 46.48 —84.51 6A 932 37
SIOUX LOOKOUT A 718420 50.12 —91.90 7 739 29
SUDBURY A 717300 46.62 —80.80 7 917 36
THUNDER BAY A 717490 48.37 —89.33 7 731 29
TIMMINS VICTOR POWER A 717390 48.57 —81.38 7 921 36
TORONTO BUTTONVILLE A 716390 43.86 —79.37 6A 781 31
TORONTO ISLAND A 712650 43.63 —79.40 5A 848 33
TORONTO LESTER B. PEARSON INT 716240 43.68 —79.63 5A 785 31
TRENTON A 716210 44.12 —77.53 6A 858 34
UPSALA (AUT) 714350 49.03 —90.47 7 715 28
WAWA (AUT) 717380 47.97 —84.78 7 906 36
WELCOME ISLAND (AUT) 717510 48.37 —89.12 7 659 26
WIARTON A 716330 44.75 —81.11 6A 1049 41
WINDSOR A 715380 42.28 —82.96 5A 920 36
Prince Edward Island (PE)
CHARLOTTETOWN A 717060 46.29 —63.13 6A 1217 48
EAST POINT (AUT) 714120 46.46 —61.99 6A 1285 51
NORTH CAPE 719870 47.06 —64.00 6A 1103 43
SUMMERSIDE 717020 46.44 —63.84 6A 1077 42
Quebec (QC)
AMQUI 713860 48.47 —67.43 7 1028 40
BAGOTVILLE A 717270 48.33 —71.00 7 966 38
BAIE-COMEAU 718290 49.26 —68.15 7 981 39
BAIE-COMEAU A 711870 49.13 —68.20 7 1045 41
BARRAGE TEMISCAMINGUE 717320 46.71 —79.10 6A 956 38
BEAUCEVILLE 713230 46.20 —70.78 7 1127 44
BLANC-SABLON A 718080 51.45 —57.18 7 1091 43
BONNARD 1 713830 50.73 —71.01 7 1006 40
CAP-CHAT 714280 49.11 —66.65 7 928 37
CAP-D'ESPOIR 714290 48.42 —64.32 7 1089 43
CAP-MADELEINE 714250 49.25 —65.32 7 897 35
CAP-ROUGE 711860 48.37 —70.54 7 944 37
CAP-TOURMENTE 713840 47.08 —70.78 6A 1104 43
CHARLEVOIX (MRC) 713190 47.28 —70.64 7 1103 43
CHEVERY 718140 50.46 —59.64 7 1161 46
CHIBOUGAMAU CHAPAIS A 718220 49.77 —74.53 7 969 38
CHUTE-DES-PASSES 715220 49.84 —71.17 7 1091 43
DESCHAMBAULT 713890 46.69 —71.97 7 1134 45
FRELIGHSBURG 713730 45.05 —72.86 6A 1180 46
GASPE A 711880 48.78 —64.48 7 1048 41
HAVRE-SAINT-PIERRE A 713130 50.28 —63.60 7 1094 43
HEATH POINT 714230 49.09 —61.70 7 1030 41
ILE AUX PERROQUETS 713750 50.22 —64.21 7 1099 43
ILE ROUGE 714260 48.07 —69.56 7 998 39
ILES DE LA MADELEINE 717100 47.43 —61.77 6A 1049 41
INUKJUAK A 719070 58.47 —78.08 8 457 18
JONQUIERE 716170 48.42 —71.15 7 948 37
KUUJJUAQ A 719060 58.10 —68.42 8 520 20
KUUJJUARAPIK A 719050 55.28 —77.75 8 667 26
LA BAIE 713880 48.30 —70.92 7 966 38
LA GRANDE IV A 718230 53.76 —73.68 8 773 30
LA GRANDE RIVIERE A 718270 53.63 —77.70 8 683 27
LA POCATIERE 717130 47.36 —70.03 6A 963 38
LA TUQUE 713780 47.41 —72.79 7 959 38
LAC BENOIT 715200 51.53 —71.11 8 925 36
LAC EON 714210 51.87 —63.28 8 1058 42
LAC SAINT-PIERRE 711980 46.18 —72.92 6A 993 39
L'ACADIE 713720 45.29 —73.35 6A 1021 40
L'ASSOMPTION 715240 45.81 —73.43 6A 999 39
LENNOXVILLE 716110 45.37 —71.82 6A 1095 43
L'ETAPE 713820 47.56 —71.23 7 1261 50
LONGUE-POINTE-DE-MINGAN 715120 50.27 —64.23 7 1108 44
MANIWAKI AIRPORT 717210 46.27 —75.99 7 966 38
MANIWAKI UA 717220 46.30 —76.01 7 928 37
MANOUANE EST 715210 50.66 —70.53 8 908 36
MATAGAMI A 718210 49.77 —77.80 7 838 33
MCTAVISH 716120 45.50 —73.58 6A 1096 43
MISTOOK 713810 48.60 —71.72 7 942 37
MONT-JOLI A 717180 48.60 —68.22 7 969 38
MONT-ORFORD 716180 45.31 —72.24 7 1082 43
MONTREAL/MIRABEL INT'L A 716260 45.67 —74.03 6A 1024 40
MONTREAL/PIERRE ELLIOTT TRUDE 716270 45.47 —73.75 6A 988 39
MONTREAL/ST-HUBERT A 713710 45.52 —73.42 6A 1027 40
MONTREAL-EST 716750 45.63 —73.55 6A 1013 40
NATASHQUAN A 718130 50.18 —61.82 7 1182 47
NEW CARLISLE 1 716190 48.01 —65.33 7 1015 40
NICOLET 717230 46.23 —72.66 6A 1026 40
NORMANDIN 713790 48.84 —72.55 7 913 36
ONATCHIWAY 713870 48.89 —71.03 7 937 37
PARENT 717260 47.92 —74.62 7 1015 40
POINTE CLAVEAU 711890 48.26 —70.11 7 995 39
POINTE NOIRE CS 713900 50.16 —66.43 7 1119 44
POINTE-AU-PERE (INRS) 715540 48.51 —68.47 7 888 35
POINTE-DES-MONTS 714270 49.32 —67.38 7 982 39
PORT-MENIER 718100 49.84 —64.29 7 1047 41
QUEBEC/JEAN LESAGE INTL A 717080 46.80 —71.38 7 1266 50
RIVIERE-DU-LOUP 717150 47.81 —69.55 7 981 39
ROBERVAL A 717280 48.52 —72.27 7 872 34
ROUYN 717340 48.25 —79.03 7 865 34
ROUYN A 717400 48.22 —78.83 7 882 35
SCHEFFERVILLE A 718280 54.80 —66.82 8 784 31
SEPT-ILES A 718110 50.22 —66.27 7 1173 46
SHERBROOKE A 716100 45.43 —71.68 7 1162 46
ST-ANICET 1 717120 45.12 —74.29 6A 968 38
STE AGATHE DES MONTS 717200 46.05 —74.28 7 1236 49
STE-ANNE-DE-BELLEVUE 1 713770 45.43 —73.93 6A 958 38
STE-CLOTHILDE 716140 45.17 —73.68 6A 925 36
STE-FOY (U. LAVAL) 713920 46.78 —71.29 6A 1266 50
ST-JOVITE 713760 46.08 —74.56 7 1130 44
TROIS-RIVIERES 717240 46.35 —72.52 6A 1024 40
VAL-D'OR A 717250 48.06 —77.79 7 981 39
VARENNES 711840 45.72 —73.38 6A 1027 40
Saskatchewan (SK)
ASSINIBOIA AIRPORT 714870 49.73 —105.93 7 400 16
BROADVIEW 718610 50.37 —102.57 7 416 16
COLLINS BAY 710750 58.18 —103.70 8 546 21
CORONACH SPC 715160 49.05 —105.48 7 338 13
CREE LAKE 719200 57.35 —107.13 8 476 19
CYPRESS HILLS PARK 711390 49.65 —109.52 7 346 14
EASTEND CYPRESS (AUT) 711310 49.43 —108.98 7 386 15
ELBOW CS 714500 51.13 —106.58 7 325 13
ESTEVAN A 718620 49.22 —102.97 7 434 17
HUDSON BAY 718680 52.82 —102.32 7 479 19
INDIAN HEAD CDA 715150 50.55 —103.65 7 444 17
KEY LAKE A 714880 57.25 —105.60 8 493 19
KINDERSLEY A 711290 51.52 —109.18 7 324 13
LA RONGE A 719220 55.15 —105.27 7 501 20
LAST MOUNTAIN CS 715560 51.42 —105.25 7 384 15
LEADER AIRPORT 714590 50.90 —109.50 7 365 14
LUCKY LAKE 714550 50.95 —107.15 7 342 13
MAPLE CREEK 714530 49.90 —109.47 6A 371 15
MEADOW LAKE A 711250 54.13 —108.52 7 431 17
MELFORT 714560 52.82 —104.60 7 416 16
MOOSE JAW A 718640 50.33 —105.55 7 375 15
MOOSE JAW CS 715390 50.33 —105.56 7 375 15
NIPAWIN A 711300 53.33 —104.00 7 453 18
NORTH BATTLEFORD A 718760 52.77 —108.26 7 391 15
OUTLOOK PFRA 715510 51.48 —107.05 7 350 14
PRINCE ALBERT A 718690 53.22 —105.67 7 426 17
REGINA A 718630 50.43 —104.67 7 395 16
ROCKGLEN (AUT) 711350 49.17 —105.98 7 335 13
ROSETOWN EAST 715100 51.57 —107.92 7 347 14
SASKATOON DIEFENBAKER INT'L A 718660 52.17 —106.72 7 364 14
SASKATOON KERNEN FARM 715130 52.15 —106.55 7 364 14
SCOTT CDA 714890 52.36 —108.83 7 388 15
SOUTHEND 714510 56.33 —103.28 8 535 21
SPIRITWOOD WEST 711330 53.37 —107.55 7 417 16
STONY RAPIDS A 711320 59.25 —105.83 8 429 17
SWIFT CURRENT A 718700 50.30 —107.68 7 389 15
SWIFT CURRENT CDA 714460 50.27 —107.73 7 389 15
URANIUM CITY (AUT) 710760 59.57 —108.48 8 379 15
VAL MARIE SOUTHEAST 711370 49.07 —107.58 7 295 12
WASKESIU LAKE 714540 53.92 —106.07 7 414 16
WATROUS EAST 715110 51.67 —105.40 7 379 15
WEYBURN 714520 49.70 —103.80 7 391 15
WYNYARD (AUT) 718650 51.77 —104.20 7 429 17
YORKTON A 711380 51.27 —102.47 7 457 18
Yukon (YT)
BURWASH A 719670 61.37 —139.05 8 302 12
FARO (AUT) 719490 62.23 —133.35 8 275 11
HAINES JUNCTION 715050 60.77 —137.58 8 334 13
HERSCHEL ISLAND 715010 69.57 —138.91 8 188 7
IVVAVIK NAT. PARK 719780 69.16 —140.15 8 176 7
KOMAKUK BEACH 710460 69.61 —140.20 8 168 7
MAYO A 719650 63.62 —135.87 8 329 13
ROCK RIVER 715060 66.98 —136.22 8 337 13
SHINGLE POINT A 719680 68.95 —137.22 8 260 10
TESLIN (AUT) 710450 60.17 —132.73 8 340 13
WATSON LAKE A 719530 60.12 —128.82 8 436 17
WHITEHORSE A 719640 60.71 —135.07 7 281 11
Table Annex1-3 ASHRAE Standard 169-2013, Table A-6: International Stations and Climate Zones
Country/LOCATION WMO# Lat Long CZ Precipitation
mm in.
Albania (ALB)
TIRANA 136150 41.33 19.78 3A 1234 49
Algeria (DZA)
ADRAR 606200 27.88 —0.18 1B 14 1
ANNABA 603600 36.83 7.82 3A 630 25
BATNA 604680 35.75 6.32 3B 362 14
BECHAR 605710 31.50 —2.25 2B 87 3
BEJAIA-AEROPORT 604020 36.72 5.07 3A 776 31
BISKRA 605250 34.80 5.73 2B 110 4
BORDJ-BOU-ARRERIDJ 604440 36.07 4.77 3B 420 17
CONSTANTINE 604190 36.28 6.62 3A 516 20
DAR-EL-BEIDA 603900 36.68 3.22 3A 701 28
DJANET 606700 24.27 9.47 2B 21 1
EL-BAYADH 605500 33.67 1.00 4B 269 11
EL-GOLEA 605900 30.57 2.87 2B 37 1
EL-OUED 605590 33.50 6.78 2B 71 3
GHARDAIA 605660 32.40 3.80 2B 65 3
HASSI-MESSAOUD 605810 31.67 6.15 2B 40 2
ILLIZI 606400 26.50 8.42 1B 18 1
IN-AMENAS 606110 28.05 9.63 2B 25 1
IN-SALAH 606300 27.23 2.50 0B 12 0
JIJEL-ACHOUAT 603510 36.80 5.88 3A 943 37
MASCARA-MATEMORE 605060 35.60 0.30 3A 443 17
MECHERIA 605490 33.58 —0.28 3B 231 9
ORAN-SENIA 604900 35.63 —0.60 3A 368 15
OUARGLA 605800 31.93 5.40 2B 50 2
SETIF 604450 36.18 5.25 4A 492 19
SKIKDA 603550 36.88 6.90 3A 734 29
TAMANRASSET 606800 22.80 5.43 2B 40 2
TAMANRASSET 606805 22.80 5.45 2B 40 2
TEBESSA 604750 35.42 8.12 3B 369 15
TIARET 605110 35.35 1.47 3B 355 14
TINDOUF 606560 27.70 —8.17 1B 51 2
TLEMCEN-ZENATA 605310 35.02 —1.47 3A 468 18
TOUGGOURT 605550 33.12 6.13 2B 58 2
American Samoa (ASM)
PAGO PAGO WSO AP 917650 —14.33 —170.71 0A 2990 118
Antarctica (ATA)
BASE ARTURO PRAT 890570 —62.50 —59.68 8 902 35
BASE ESPERANZA 889630 —63.40 —56.98 8 840 33
BASE JUBANY 890530 —62.23 —58.63 8 905 36
BASE MARAMBIO 890550 —64.23 —56.72 8 792 31
BASE ORCADAS 889680 —60.73 —44.73 8 902 35
BASE SAN MARTIN 890660 —68.12 —67.13 8 624 25
BELLINGSHAUSEN AWS 890500 —62.20 —58.93 8 905 36
BERNARDO O'HIGGINS 890590 —63.32 —57.90 8 858 34
BUTLER ISLAND 892660 —72.21 —60.17 8 610 24
CASEY 896110 —66.28 110.52 8 398 16
DAVIS 895710 —68.58 77.95 8 281 11
DINAMET-URUGUAY 890540 —62.18 —58.83 8 905 36
DUMONT DURVILLE 896420 —66.67 140.02 8 431 17
FREI CHI-BASE 890560 —62.18 —58.98 8 905 36
GREAT WALL 890580 —62.22 —58.97 8 905 36
HALLEY 890220 —75.50 —26.65 8 307 12
MANUELA 898640 —74.95 163.69 8 350 14
MARBLE POINT 898660 —77.43 163.75 8 190 7
MAWSON 895640 —67.60 62.87 8 307 12
MIRNYJ 895920 —66.55 93.02 8 745 29
MOLODEZNAJA 895420 —67.67 45.85 8 529 21
MOUNT SIPLE 893270 —73.20 —127.05 8 504 20
NEUMAYER 890020 —70.67 —8.25 8 394 16
NOVOLAZAREVSKAJA 895120 —70.77 11.83 8 354 14
POSSESSION ISLAND 898790 —71.89 171.21 8 453 18
SIPLE DOME 893450 —81.65 —148.77 8 285 11
SYOWA 895320 —69.00 39.58 8 449 18
Antigua and Barbuda (ATG)
VC BIRD INTL AIRPOR 788620 17.12 —61.78 0A 883 35
Argentina (ARG)
AEROPARQUE BS. AS. 875820 —34.57 —58.42 3A 1049 41
BAHIA BLANCA AERO 877500 —38.73 —62.17 3A 632 25
BARILOCHE AERO 877650 —41.15 —71.17 5C 801 32
CATAMARCA AERO. 872220 —28.60 —65.77 2B 383 15
CERES AERO 872570 —29.88 —61.95 3A 936 37
COMODORO RIVADAVIA 878600 —45.78 —67.50 4C 238 9
CONCORDIA AERO 873950 —31.30 —58.02 3A 1298 51
CORDOBA AERO 873440 —31.32 —64.22 3A 827 33
CORRIENTES AERO. 871660 —27.45 —58.77 2A 1460 57
ESQUEL AERO 878030 —42.93 —71.15 5C 488 19
EZEIZA AERO 875760 —34.82 —58.53 3A 967 38
FORMOSA AERO 871620 —26.20 —58.23 2A 1411 56
GUALEGUAYCHU AERO 874970 —33.00 —58.62 3A 1038 41
IGUAZU AERO 870970 —25.73 —54.47 2A 1826 72
JUJUY AERO 870460 —24.38 —65.08 3A 818 32
JUNIN AERO 875480 —34.55 —60.92 3A 983 39
LA RIOJA AERO. 872170 —29.38 —66.82 2B 361 14
LAGO ARGENTINO ARPT 879030 —50.33 —72.30 5C 200 8
MALARGUE AERO 875060 —35.50 —69.58 4B 285 11
MAR DEL PLATA AERO 876920 —37.93 —57.58 3A 879 35
MARCOS JUAREZ AERO 874670 —32.70 —62.15 3A 884 35
MENDOZA AERO 874180 —32.83 —68.78 3B 196 8
MONTE CASEROS AERO 873930 —30.27 —57.65 2A 1466 58
NEUQUEN AERO 877150 —38.95 —68.13 3B 194 8
PARANA AERO 873740 —31.78 —60.48 3A 1025 40
PASO DE LOS LIBRES 872890 —29.68 —57.15 2A 1492 59
POSADAS AERO. 871780 —27.37 —55.97 2A 1686 66
PRESIDENCIA ROQUE S 871490 —26.82 —60.45 2A 1054 41
RECONQUISTA AERO 872700 —29.18 —59.70 2A 1206 47
RESISTENCIA AERO 871550 —27.45 —59.05 2A 1335 53
RIO CUARTO AERO 874530 —33.12 —64.23 3A 827 33
RIO GALLEGOS AERO 879250 —51.62 —69.28 5B 253 10
RIO GRANDE B.A. 879340 —53.80 —67.75 6A 325 13
ROSARIO AERO 874800 —32.92 —60.78 3A 977 38
SALTA AERO 870470 —24.85 —65.48 3A 740 29
SAN ANTONIO OESTE A 877840 —40.78 —65.10 3B 242 10
SAN JUAN AERO 873110 —31.40 —68.42 3B 92 4
SAN JULIAN AERO 879090 —49.32 —67.75 5B 243 10
SAN LUIS AERO 874360 —33.27 —66.35 3B 617 24
SAN MARTIN 874160 —33.08 —68.42 3B 169 7
SAN RAFAEL AERO 875090 —34.58 —68.40 3B 336 13
SANTA ROSA AERO 876230 —36.57 —64.27 3A 695 27
SANTIAGO DEL ESTERO 871290 —27.77 —64.30 2B 577 23
SAUCE VIEJO AERO 873710 —31.70 —60.82 3A 991 39
TANDIL AERO 876450 —37.23 —59.25 3A 969 38
TARTAGAL AERO 870220 —22.65 —63.82 2A 1008 40
TRELEW AERO 878280 —43.20 —65.27 3B 183 7
TUCUMAN AERO 871210 —26.85 —65.10 2A 1078 42
USHUAIA AERO 879380 —54.80 —68.32 6A 525 21
VIEDMA AERO 877910 —40.85 —63.02 3B 353 14
VILLA REYNOLDS AERO 874480 —33.73 —65.38 3A 700 28
Armenia (ARM)
AMASIA 376820 40.78 43.83 6A 599 24
SEVAN 377090 40.55 44.93 6A 498 20
YEREVAN/YEREVAN-ARA 377890 40.13 44.47 4B 342 13
Aruba (ABW)
QUEEN BEATRIX AIRPO 789820 12.50 —70.02 0B 417 16
Australia (AUS)
ADELAIDE AIRPORT 946720 —34.95 138.53 3B 446 18
ADELAIDE REGIONAL O 946750 —34.92 138.62 3A 552 22
ADELE ISLAND 942100 —15.52 123.15 0A 847 33
AIREYS INLET 948460 —38.45 144.10 3A 679 27
ALBANY AIRPORT 948020 —34.93 117.80 3C 806 32
ALBURY AEROPORT 958960 —36.07 146.95 3A 722 28
ALICE SPRINGS AIRPO 943260 —23.80 133.88 2B 296 12
AMBERLEY AMO 945680 —27.63 152.72 2A 859 34
APPLETHORPE GBHRS A 945530 —28.62 151.95 3A 784 31
ARARAT PRISON 948340 —37.28 142.98 4A 594 23
ARCHERFIELD AIRPORT 945750 —27.57 153.00 2A 1178 46
ARGYLE AERODROME 942170 —16.63 128.45 0B 725 29
AVALON AIRPORT 948540 —38.03 144.47 3A 564 22
BALLARAT AERODROME 948520 —37.52 143.78 4A 681 27
BANKSTOWN AIRPORT A 947650 —33.92 150.98 3A 911 36
BATCHELOR AERO 941250 —13.05 131.02 0A 1389 55
BATHURST AIRPORT AW 947290 —33.42 149.65 4A 654 26
BEGA AWS 959310 —36.67 149.82 3A 839 33
BENDIGO AIRPORT AWS 948550 —36.73 144.32 3A 582 23
BILOELA THANGOOL AI 943760 —24.48 150.57 2B 661 26
BIRDSVILLE POLICE S 944820 —25.90 139.35 2B 172 7
BOMBALA AWS 949290 —37.00 149.23 4A 660 26
BORROLOOLA 941520 —16.08 136.30 1A 935 37
BOULIA AIRPORT 943330 —22.92 139.90 1B 259 10
BOURKE AIRPORT AWS 947030 —30.03 145.95 2B 366 14
BOWEN AIRPORT 943660 —20.02 148.20 1A 974 38
BRAIDWOOD RACECOURS 949270 —35.43 149.78 4A 773 30
BRISBANE AERO 945780 —27.38 153.13 2A 1130 44
BROKEN HILL AIRPORT 946910 —32.00 141.47 3B 266 10
BROOME AIRPORT 942030 —17.95 122.23 0B 660 26
BUNDABERG AERO 943870 —24.90 152.32 2A 1015 40
BURKETOWN POST OFFI 942590 —17.75 139.55 1B 753 30
BUSSELTON AERO 956110 —33.68 115.40 3C 791 31
CAIRNS AERO 942870 —16.88 145.75 1A 2013 79
CAMDEN AIRPORT 947550 —34.03 150.68 3A 857 34
CANBERRA AIRPORT 949260 —35.30 149.20 4A 614 24
CANTERBURY RACECOUR 947660 —33.90 151.12 3A 1104 43
CAPE BORDA 948050 —35.75 136.58 3C 604 24
CAPE BRUNY LIGHTHOU 949670 —43.50 147.15 4A 1006 40
CAPE DON AWS 941290 —11.32 131.77 0A 1310 52
CAPE FOURCROY 941220 —11.78 130.02 0A 1845 73
CAPE GRIM B.A.P.S. 949540 —40.67 144.68 4A 946 37
CAPE JAFFA AWS 948130 —36.97 139.72 3C 569 22
CAPE LEEUWIN 946010 —34.37 115.13 3C 1017 40
CAPE MORETON LIGHTH 945940 —27.03 153.47 2A 1532 60
CAPE NATURALISTE 946000 —33.53 115.02 3C 834 33
CAPE NELSON LIGHTHO 948260 —38.43 141.55 3C 774 30
CAPE OTWAY LIGHTHOU 948420 —38.85 143.52 3A 954 38
CAPE SORELL 949740 —42.20 145.17 4A 1603 63
CAPE WESSEL AWS 941470 —11.02 136.75 0A 1365 54
CARNARVON AIRPORT 943000 —24.88 113.67 2B 211 8
CATO ISLAND 943940 —23.25 155.53 1A 814 32
CEDUNA AMO 946530 —32.13 133.70 3C 287 11
CENTRE ISLAND 942480 —15.75 136.80 0A 981 39
CERBERUS AWS 948980 —38.35 145.17 3A 807 32
CESSNOCK AIRPORT 957710 —32.78 151.33 3A 746 29
CHARLEVILLE AERO 945100 —26.42 146.27 2B 476 19
COBAR AIRPORT AWS 947100 —31.53 145.80 3B 405 16
COBAR MO 947110 —31.48 145.83 3B 405 16
COCONUT ISLAND 941820 —10.05 143.07 0A 1522 60
COFFS HARBOUR MO 947910 —30.32 153.12 3A 1649 65
COMBIENBAR 949140 —37.33 149.02 4A 971 38
CONDOBOLIN AIRPORT 957080 —33.07 147.22 3B 468 18
COOBER PEDY AIRPORT 954580 —29.03 134.72 2B 173 7
COOKTOWN MISSION 942830 —15.43 145.18 1A 1732 68
COOLANGATTA AIRPORT 945920 —28.17 153.50 2A 1710 67
COOMA AIRPORT AWS 949210 —36.30 148.97 4A 541 21
COONABARABRAN NAMOI 947280 —31.27 149.27 3A 826 33
CREAL REEF 943710 —20.53 150.38 1A 858 34
CUNDERDIN AIRFIELD 956250 —31.62 117.22 3A 371 15
CUNNAMULLA POST OFF 945000 —28.07 145.68 2B 384 15
CURTIN AERO 942040 —17.58 123.82 0B 752 30
DARWIN AIRPORT 941200 —12.42 130.88 0A 1730 68
DERBY AERO 952050 —17.37 123.67 0B 632 25
DEVONPORT AIRPORT 959600 —41.17 146.42 4A 792 31
DOUBLE ISLAND POINT 945840 —25.93 153.18 2A 1569 62
DUBBO AIRPORT AWS 957190 —32.22 148.57 3A 617 24
DUNNS HILL 948720 —37.88 145.33 4A 936 37
EAST SALE AIRPORT 949070 —38.10 147.13 3A 586 23
EDDYSTONE POINT 949830 —41.00 148.35 3A 804 32
EDITHBURGH AWS 948090 —35.12 137.73 3C 392 15
EILDON FIRE TOWER 948810 —37.22 145.83 4A 827 33
EMERALD AIRPORT 943630 —23.57 148.18 2B 646 25
ESPERANCE 946380 —33.83 121.88 3C 611 24
ESPERANCE AERO 956380 —33.68 121.83 3C 549 22
FALLS CREEK AWS 949030 —36.87 147.27 6A 1197 47
FLINDERS ISLAND AIR 949800 —40.10 148.00 3A 745 29
FLINDERS REEF 942900 —17.72 148.45 1A 945 37
FORBES AIRPORT 947150 —33.37 147.92 3A 558 22
FORREST 956460 —30.83 128.12 3B 199 8
FRANKSTON AWS 948710 —38.15 145.12 3A 773 30
GABO ISLAND 949330 —37.57 149.90 3A 958 38
GANNET CAY 943790 —21.97 152.47 1A 821 32
GAYNDAH POST OFFICE 945430 —25.63 151.62 2A 723 28
GEELONG AIRPORT 948570 —38.23 144.33 3A 564 22
GELANTIPY 949130 —37.22 148.27 4A 794 31
GEORGETOWN POST OFF 942750 —18.30 143.55 1A 812 32
GERALDTON AIRPORT 944030 —28.80 114.70 3A 443 17
GILES METEOROLOGICA 944610 —25.03 128.30 2B 271 11
GLADSTONE AIRPORT 943810 —23.87 151.22 2A 919 36
GLADSTONE RADAR 943800 —23.85 151.27 2A 919 36
GLEN INNES AIRPORT 945880 —29.68 151.70 4A 911 36
GOLD COAST SEAWAY 945800 —27.93 153.43 2A 1522 60
GOLDSTREAM 948640 —37.73 145.40 4A 889 35
GOONDIWINDI AIRPORT 945300 —28.52 150.32 2A 584 23
GOULBURN AIRPORT AW 957160 —34.82 149.73 4A 680 27
GOVE AIRPORT 941500 —12.28 136.82 1A 1437 57
GREEN ISLAND 952890 —16.77 145.97 1A 2315 91
GRIFFITH AWS 947050 —34.32 146.07 3B 407 16
HALLS CREEK AIRPORT 942120 —18.23 127.67 0B 586 23
HAMILTON AIRPORT 948290 —37.65 142.07 4A 667 26
HAY AWS 947010 —34.53 144.87 3B 398 16
HERON ISLAND RES ST 943860 —23.45 151.92 1A 876 34
HOBART AIRPORT 949750 —42.83 147.50 4A 495 19
HOBART ELLERSLIE RO 949700 —42.88 147.33 4A 589 23
HOLMES REEF 942890 —16.47 147.87 1A 1263 50
HOMEBUSH (OLYMPIC SITE) 957650 —33.85 151.07 3A 928 37
HUNTERS HILL 948780 —36.22 147.53 4A 934 37
JABIRU AIRPORT 941370 —12.67 132.90 0A 1450 57
JACUP 956360 —33.88 119.10 3B 429 17
JANDAKOT AERO 946090 —32.10 115.88 3A 838 33
KALGOORLIE-BOULDER 946370 —30.78 121.45 3B 275 11
KARRATHA AERO 953070 —20.72 116.77 1B 252 10
KARRATHA LEGENDRE I 943070 —20.37 116.85 1B 405 16
KATANNING 946290 —33.68 117.55 3A 480 19
KATOOMBA 947440 —33.72 150.28 4A 1390 55
KHANCOBAN 949190 —36.23 148.13 3A 961 38
KILMORE GAP 948600 —37.38 144.97 4A 699 28
KING ISLAND AIRPORT 948500 —39.88 143.88 4C 888 35
KING ISLAND CURRIE 948510 —39.93 143.85 3C 888 35
KUNUNURRA AERO 942160 —15.78 128.72 0B 779 31
KYANCUTTA 946570 —33.13 135.55 3B 300 12
LADY ELLIOT ISLAND 943880 —24.12 152.72 2A 1166 46
LAKE GRACE 946350 —33.12 118.47 3B 345 14
LANCELIN 956060 —31.02 115.32 3A 600 24
LATROBE VALLEY AIRP 948910 —38.22 146.47 3A 760 30
LAUNCESTON AIRPORT 949680 —41.53 147.20 4A 652 26
LAVERTON AERO 944490 —28.62 122.42 2B 246 10
LAVERTON AERODROME 948650 —37.87 144.75 3A 547 22
LEARMONTH AIRPORT 943020 —22.23 114.08 1B 235 9
LEINSTER AERO 954480 —27.85 120.70 2B 238 9
LEONORA POST OFFICE 944480 —28.88 121.33 2B 249 10
LIHOU REEF 942960 —17.12 152.00 1A 1026 40
LONGERENONG 958350 —36.67 142.30 3B 422 17
LONGREACH AERO 943460 —23.43 144.28 1B 418 16
LOOKOUT HILL 948350 —37.28 143.25 5A 675 27
LORD HOWE ISLAND AE 949950 —31.53 159.07 3A 1456 57
LOW ROCKY POINT (AWS) 959610 —42.98 145.50 4A 1922 76
LUCINDA POINT AWS 942950 —18.52 146.40 1A 2183 86
MAATSUYKER ISLAND L 949620 —43.65 146.27 4A 1377 54
MACKAY MO 943670 —21.12 149.22 2A 1563 62
MACQUARIE ISLAND 949980 —54.50 158.95 6A 947 37
MALLACOOTA 949350 —37.60 149.73 3A 1020 40
MANDURAH 946050 —32.52 115.72 3A 842 33
MANGALORE AWS COMPO 948740 —36.88 145.18 3A 574 23
MANGROVE MOUNTAIN A 957740 —33.28 151.22 3A 1059 42
MARION REEF 942980 —19.08 152.38 1A 858 34
MARLA POLICE STATIO 944770 —27.30 133.62 2B 229 9
MAROOCHYDORE AERO 945690 —26.60 153.10 2A 1687 66
MARYBOROUGH COMPOSI 945670 —25.52 152.72 2A 1070 42
MEEKATHARRA AIRPORT 944300 —26.62 118.55 2B 246 10
MELBOURNE 948680 —37.82 144.97 3A 635 25
MELBOURNE AIRPORT 948660 —37.67 144.85 3A 537 21
MILDURA AIRPORT 946930 —34.23 142.08 3B 280 11
MILINGIMBI 941400 —12.12 134.90 0A 1199 47
MOOMBA AIRPORT 954810 —28.10 140.20 2B 175 7
MOORABBIN AIRPORT 948700 —37.98 145.10 3A 724 29
MOREE 945270 —29.47 149.85 3A 588 23
MOREE AERO 955270 —29.48 149.83 3A 588 23
MORTLAKE AWS 948400 —38.07 142.77 4A 685 27
MORUYA HEADS PILOT 949370 —35.92 150.15 3A 1014 40
MOUNT BOYCE 947430 —33.62 150.27 4A 1184 47
MOUNT BULLER AWS 948940 —37.15 146.43 6A 1243 49
MOUNT GAMBIER AERO 948210 —37.73 140.78 3C 696 27
MOUNT ISA AERO 943320 —20.68 139.48 1B 446 18
MOUNT LAWLEY PERTH 946080 —31.92 115.87 3A 820 32
MT HOTHAM AWS 949060 —36.97 147.12 7 1336 53
MT LOFTY AWS 956780 —34.97 138.70 4C 651 26
MT MOORNAPA 959130 —37.75 147.13 4A 685 27
MT WELLINGTON 959790 —42.88 147.23 7 662 26
MUDGEE AIRPORT AWS 947270 —32.57 149.62 3A 709 28
NAMBOUR DPI 955720 —26.65 152.93 2A 1680 66
NEPTUNE ISLAND 948040 —35.33 136.12 3C 467 18
NEWCASTLE NOBBYS SI 947740 —32.92 151.78 3A 1130 44
NORAH HEAD LIGHTHOU 957700 —33.27 151.57 3A 1206 47
NORMANTON 942670 —17.67 141.08 0A 853 34
NORSEMAN 946390 —32.20 121.78 3B 305 12
NORTH EAST ISLAND 941510 —13.65 136.93 0A 963 38
NOWRA RAN AIR STATI 947500 —34.95 150.53 3A 1075 42
NULLARBOR ROADHOUSE 946510 —31.45 130.90 3B 265 10
NULLO MOUNTAIN AWS 947540 —32.73 150.23 4A 731 29
OAKEY AERO 945520 —27.42 151.73 3A 638 25
ONSLOW 943050 —21.63 115.12 1B 287 11
OUSE FIRE STATION 949570 —42.48 146.72 4A 544 21
PARABURDOO AERO 943160 —23.17 117.75 1B 267 10
PARKES (MACARTHUR ST) 947170 —33.13 148.17 3A 634 25
PAYNES FIND 944040 —29.27 117.68 2B 279 11
PEARCE RAAF 946120 —31.67 116.02 3A 660 26
PENRITH 947630 —33.72 150.68 3A 883 35
PERTH AIRPORT 946100 —31.93 115.97 3A 763 30
POINT WILSON 948470 —38.10 144.53 3A 561 22
PORT ARTHUR (PALM.) 949780 —43.17 147.83 4A 1165 46
PORT FAIRY AWS 948300 —38.40 142.23 3A 801 32
PORT HEDLAND AIRPOR 943120 —20.37 118.63 1B 277 11
PORT KEATS AWS AUT 941110 —14.23 129.45 0A 1491 59
PORT MACQUARIE AIRP 947860 —31.43 152.85 3A 1522 60
PORTLAND CASHMORE A 948280 —38.32 141.47 4C 812 32
PROSERPINE AIRPORT 943650 —20.50 148.53 2A 1455 57
QUILPIE AIRPORT 944940 —26.62 144.25 2B 365 14
RAVENSTHORPE HOPETO 956350 —33.93 120.13 3C 519 20
REDESDALE 948590 —37.02 144.53 4A 697 27
RENMARK 946870 —34.17 140.75 3B 259 10
RHYLL (AWS) 948920 —38.45 145.30 3A 829 33
RICHMOND POST OFFIC 943400 —20.73 143.13 1B 489 19
RICHMOND RAAF 957530 —33.60 150.78 3A 842 33
ROCKHAMPTON AERO 943740 —23.38 150.48 2A 791 31
ROEBOURNE POST OFFI 943090 —20.78 117.15 0B 296 12
ROMA AIRPORT 945150 —26.55 148.78 2A 616 24
ROTTNEST ISLAND 946020 —32.02 115.50 3A 629 25
RUNDLE ISLAND 943780 —23.53 151.28 2A 863 34
SCONE AIRPORT 957580 —32.03 150.83 3A 708 28
SCORESBY RESEARCH 958670 —37.87 145.25 3A 936 37
SHARK BAY (DENHAM) 944020 —25.92 113.52 2B 221 9
SHEOAKS AWS 948630 —37.90 144.12 4A 613 24
SHEPPARTON AIRPORT 948750 —36.43 145.40 3A 504 20
SMITHTON AERODROME 949530 —40.83 145.08 4C 1105 44
SOUTHERN CROSS 946340 —31.23 119.33 3B 323 13
SOUTHERN CROSS AIRF 956340 —31.23 119.35 3B 323 13
ST LAWRENCE POST OF 943690 —22.35 149.53 2A 990 39
STRAHAN AERODROME 949560 —42.15 145.28 4A 2101 83
SWAN HILL AERODROME 948430 —35.38 143.53 3B 337 13
SWANBOURNE 946140 —31.95 115.77 3A 820 32
SYDNEY AIRPORT AMO 947670 —33.93 151.18 3A 1104 43
SYDNEY REGIONAL OFF 947680 —33.85 151.20 3A 1253 49
TAMWORTH AIRPORT AW 957620 —31.07 150.83 3A 676 27
TELFER AERO 943190 —21.72 122.22 1B 302 12
TENNANT CREEK MET O 942380 —19.63 134.18 1B 446 18
TEWANTIN RSL PARK 945700 —26.38 153.03 2A 1678 66
THREDBO (CRACKENBACK) 959090 —36.50 148.28 7 975 38
TINDAL RAAF 941310 —14.52 132.37 0A 1013 40
TOOWOOMBA AIRPORT 955510 —27.55 151.92 3A 937 37
TOWN OF 1770 943840 —24.15 151.88 2A 1104 43
TOWNSVILLE AERO 942940 —19.25 146.77 1A 1042 41
TROUGHTON ISLAND 941020 —13.75 126.15 0A 955 38
TUGGERANONG ISABELL 949250 —35.42 149.10 4A 733 29
TUNNAK FIRE STATION 949600 —42.45 147.47 5A 611 24
ULLADULLA AWS 949380 —35.35 150.48 3A 1254 49
URANDANGIE 943290 —21.60 138.30 1B 314 12
VICTORIA RIVER DOWN 942320 —16.40 131.02 0B 743 29
WAGGA WAGGA AMO 949100 —35.17 147.45 3A 574 23
WALGETT AIRPORT 957150 —30.03 148.12 2B 507 20
WANGARATTA AERO 948890 —36.42 146.30 3A 679 27
WARBURTO POINT 946660 —34.00 137.53 3B 351 14
WARRNAMBOOL AIRPORT 948320 —38.28 142.43 4C 775 30
WARWICK 945550 —28.20 152.10 3A 728 29
WEIPA AERO 941700 —12.68 141.92 0A 1883 74
WILLIAMTOWN RAAF 947760 —32.80 151.83 3A 1144 45
WILLIS ISLAND 942990 —16.30 149.97 1A 1029 41
WILSONS PROMONTORY 948930 —39.12 146.42 3C 1088 43
WINDORAH 944880 —25.42 142.65 2B 269 11
WINTON (POST OFFICE) 943390 —22.38 143.03 1B 397 16
WONTHAGGI COMPOSITE 958810 —38.60 145.58 3A 954 38
WOOMERA AERODROME 946590 —31.15 136.82 3B 184 7
WYNDHAM 942140 —15.48 128.12 0B 759 30
WYNYARD AIRPORT 959570 —41.00 145.73 4C 960 38
YEPPOON AWS 943730 —23.13 150.75 2A 1220 48
YOUNG AIRPORT 947120 —34.25 148.25 3A 668 26
YULARA AERO 944620 —25.20 130.98 2B 333 13
Austria (AUT)
AIGEN IM ENNSTAL 111570 47.53 14.13 6A 1300 51
ALLENTSTEIG 110190 48.68 15.37 5A 629 25
ALPINZENTRUM RUDOLF 111380 47.13 12.63 7 1130 44
AMSTETTEN 110180 48.10 14.90 5A 989 39
ARRIACH 112750 46.73 13.85 6A 1322 52
BAD RADKERSBURG 112480 46.68 15.98 5A 943 37
BISCHOFSHOFEN 111410 47.40 13.22 5A 1314 52
BREGENZ 111010 47.50 9.75 5A 1784 70
BRENNER 111280 47.00 11.52 6A 933 37
DELLACH IM DRAUTAL 112700 46.73 13.08 5A 1073 42
DORNBIRN 113020 47.43 9.73 5A 1393 55
EISENSTADT 111900 47.85 16.53 5A 610 24
FELDKIRCH 111050 47.27 9.62 5A 1393 55
FEUERKOGEL 111550 47.82 13.72 7 1361 54
FREISTADT 110150 48.50 14.50 5A 779 31
GMUNDEN 111540 47.90 13.80 5A 1416 56
GRAZ-THALERHOF-FLUG 112400 47.00 15.43 5A 847 33
GUMPOLDSKIRCHEN 110820 48.03 16.28 5A 604 24
HAHNENKAMM/EHRENBAC 111350 47.42 12.37 7 1242 49
HOHE WAND/HOCHKOGEL 113850 47.82 16.03 6A 745 29
INNSBRUCK-FLUGHAFEN 111200 47.27 11.35 5A 914 36
ISCHGL/IDALPE 113100 46.98 10.32 7 789 31
JAUERLING 110240 48.33 15.33 6A 646 25
KLAGENFURT-FLUGHAFE 112310 46.65 14.33 5A 905 36
KLEINZICKEN 111920 47.20 16.33 5A 741 29
KOETSCHACH-MAUTHEN 112550 46.68 13.00 5A 1427 56
KREMSMUENSTER 110120 48.05 14.13 5A 955 38
KUFSTEIN 111300 47.58 12.17 5A 1440 57
LANDECK 111120 47.13 10.57 5A 913 36
LANGENLOIS 110750 48.47 15.70 5A 574 23
LASSNITZHOEHE 112920 47.07 15.58 5A 869 34
LIENZ 112040 46.83 12.82 5A 1207 48
LILIENFELD/TARSCHBE 110780 48.03 15.58 5A 838 33
LINZ/HOERSCHING-FLU 110100 48.23 14.18 5A 955 38
LINZ/STADT 110600 48.30 14.28 5A 840 33
LITSCHAU 110210 48.95 15.03 6A 691 27
LUNZ 111700 47.85 15.07 6A 1229 48
MARIAPFARR 113480 47.15 13.75 6A 980 39
MARIAZELL 111720 47.77 15.32 6A 1066 42
MATTSEE 111520 47.98 13.10 5A 1400 55
MOENICHKIRCHEN 111850 47.52 16.03 6A 855 34
MURAU 112800 47.12 14.18 6A 962 38
NEUSIEDL 111940 47.95 16.85 5A 605 24
OBERTAUERN 111490 47.25 13.57 7 976 38
POYSDORF 110320 48.67 16.63 5A 527 21
PUCHBERG 113820 47.78 15.90 5A 991 39
RAMSAU/DACHSTEIN 113510 47.43 13.63 6A 1349 53
RAX/SEILBAHN-BERGST 111800 47.72 15.78 7 1039 41
REICHENAU/RAX 113800 47.70 15.83 5A 1039 41
RETZ 110220 48.77 15.95 5A 512 20
SALZBURG-FLUGHAFEN 111500 47.80 13.00 5A 1174 46
SCHMITTENHOEHE 113400 47.33 12.73 7 1364 54
SCHOECKL 112410 47.20 15.47 7 917 36
ST. MICHAEL/LEOBEN 111740 47.33 15.00 5A 1027 40
ST. POELTEN 110280 48.18 15.62 5A 690 27
ST. WOLFGANG 113570 47.73 13.45 5A 1465 58
STIFT ZWETTL 110200 48.62 15.20 6A 744 29
TULLN 110300 48.32 16.12 5A 606 24
VILLACH 112130 46.62 13.88 5A 1322 52
VIRGEN 112520 47.00 12.45 6A 921 36
WARTH 113080 47.25 10.18 6A 1500 59
WIEN/CITY 110340 48.20 16.37 4A 604 24
WIEN/HOHE WARTE 110350 48.25 16.37 5A 628 25
WIEN/SCHWECHAT-FLUG 110360 48.12 16.57 5A 558 22
WIENER NEUSTADT 111820 47.83 16.22 5A 745 29
WINDISCHGARSTEN 113550 47.73 14.33 5A 1190 47
ZELL AM SEE 111440 47.33 12.80 5A 1409 55
ZELTWEG 111650 47.20 14.75 6A 847 33
Azerbaijan (AZE)
LANKARAN 379850 38.73 48.83 4A 1167 46
ZAKATALA 375750 41.67 46.65 4A 975 38
Bahamas (BHS)
NASSAU AIRPORT NEW 780730 25.05 —77.47 1A 1334 53
SETTLEMENT POINT 994390 26.68 —79.00 1A 1281 50
Bahrain (BHR)
BAHRAIN (INT. AIRPORT) 411500 26.27 50.65 0B 57 2
Barbados (BRB)
GRANTLEY ADAMS 789540 13.07 —59.48 0A 1155 45
Belarus (BLR)
BARANOVICHI 269410 53.12 26.00 6A 610 24
BOBRUISK 269610 53.22 29.18 6A 622 24
BREST 330080 52.12 23.68 5A 601 24
GOMEL 330410 52.40 30.95 6A 591 23
GRODNO 268250 53.60 24.05 6A 608 24
KOSTUCKOVICHI 268870 53.35 32.07 6A 585 23
LEPEL 266590 54.88 28.70 6A 672 26
LIDA 268320 53.85 25.32 6A 655 26
LYNTUPY 266450 55.05 26.32 6A 678 27
MINSK 268500 53.93 27.63 6A 673 27
MOGILEV 268630 53.95 30.07 6A 623 25
MOZYR 330360 51.95 29.17 6A 615 24
ORSHA 267630 54.50 30.42 6A 617 24
PINSK 330190 52.12 26.12 6A 575 23
SLUTSK 269510 53.03 27.55 6A 599 24
VERHNEDVINSK 265540 55.82 27.95 6A 614 24
VITEBSK 266660 55.17 30.22 6A 662 26
ZHITCKOVICHI 330270 52.22 27.87 6A 663 26
Belgium (BEL)
ANTWERPEN/DEURNE 64500 51.20 4.47 4A 792 31
BEAUVECHAIN 64580 50.75 4.77 5A 807 32
BIERSET 64780 50.65 5.45 5A 899 35
BRUXELLES NATIONAL 64510 50.90 4.53 4A 784 31
CHARLEROI/GOSSELIES 64490 50.47 4.45 5A 883 35
CHIEVRES 64320 50.57 3.83 5A 767 30
ELSENBORN 64960 50.47 6.18 6A 1092 43
FLORENNES 64560 50.23 4.65 5A 984 39
GENT/INDUSTRIE-ZONE 64310 51.18 3.82 4A 772 30
KLEINE BROGEL 64790 51.17 5.47 5A 829 33
KOKSIJDE 64000 51.08 2.65 4A 697 27
LIEGE 64324 50.63 5.45 5A 899 35
OOSTENDE (AIRPORT) 64070 51.20 2.87 5A 755 30
OOSTENDE (PIER) 64080 51.23 2.92 4A 755 30
SEMMERZAKE 64280 50.93 3.67 4A 810 32
ST. TRUIDEN (BAFB) 64700 50.80 5.20 5A 823 32
ST-HUBERT 64760 50.03 5.40 5A 998 39
UCCLE 64470 50.80 4.35 4A 829 33
Belize (BLZ)
BELIZE/PHILLIP GOLD 785830 17.53 —88.30 0A 1944 77
Benin (BEN)
BOHICON 653380 7.17 2.07 0A 1145 45
COTONOU 653440 6.35 2.38 0A 1297 51
KANDI 653060 11.13 2.93 0A 1011 40
NATITINGOU 653190 10.32 1.38 0A 1242 49
PARAKOU 653300 9.35 2.62 0A 1177 46
SAVE 653350 8.03 2.47 0A 1116 44
Bermuda (BMU)
BERMUDA INTL 780160 32.37 —64.68 2A 1456 57
Bolivia (BOL)
COCHABAMBA 852230 —17.42 —66.18 3B 472 19
LA PAZ/ALTO 852010 —16.52 —68.18 5A 535 21
VIRU-VIRU 852440 —17.63 —63.13 1A 1365 54
Bosnia and Herzegovina (BIH)
BANJA LUKA 132420 44.78 17.22 4A 1056 42
BIHAC 132280 44.82 15.88 4A 1252 49
BJELASNICA 146520 43.72 18.27 7 1155 45
MOSTAR 133480 43.33 17.78 3A 1632 64
SARAJEVO/BUTMIR 133530 43.82 18.33 5A 993 39
SARAJEVO-BJELAVE 146540 43.87 18.43 5A 921 36
Botswana (BWA)
SERETSE KHAMA INTER 682400 —24.55 25.92 2B 449 18
Brazil (BRA)
ANAPOLIS (BRAZ-AFB) 834190 —16.23 —48.97 2A 1584 62
ARACAJU (AEROPORTO) 830950 —10.98 —37.07 0A 1489 59
BELEM (AEROPORTO) 821930 —1.38 —48.48 0A 2958 116
BELO HORIZONTE 835870 —19.93 —43.93 2A 1477 58
BELO HORIZONTE (AERO) 835830 —19.85 —43.95 2A 1477 58
BOA VISTA (AEROPORTO) 820220 2.83 —60.70 0A 1547 61
BRASILIA (AEROPORTO) 833780 —15.87 —47.93 2A 1515 60
CAMPINAS (AEROPORTO) 837210 —23.00 —47.13 2A 1354 53
CAMPO GRANDE (AERO) 836120 —20.47 —54.67 1A 1498 59
CARAVELAS (AEROPORTO) 834970 —17.63 —39.25 1A 1472 58
CUIABA (AEROPORTO) 833620 —15.65 —56.10 0A 1346 53
CURITIBA (AEROPORTO) 838400 —25.52 —49.17 3A 1604 63
EDUARDO GOMES INTL 821110 —3.03 —60.05 0A 2282 90
FERNANDO DE NORONHA 824000 —3.85 —32.42 0A 1029 41
FLORIANOPOLIS (AERO) 838990 —27.67 —48.55 2A 1578 62
FORTALEZA (AEROPORTO) 823980 —3.78 —38.53 0A 1628 64
FOZ DO IGUACU (AERO) 838270 —25.52 —54.58 2A 1788 70
GALEAO 837460 —22.82 —43.25 1A 1397 55
GOIANIA (AEROPORTO) 834240 —16.63 —49.22 1A 1628 64
GUARULHOS 837753 —23.43 —46.47 2A 1472 58
LONDRINA (AEROPORTO) 837680 —23.33 —51.13 2A 1551 61
MACAPA 820980 0.03 —51.05 0A 2733 108
MACEIO (AEROPORTO) 829930 —9.52 —35.78 1A 1627 64
MANAUS (AEROPORTO) 823320 —3.15 —59.98 0A 2282 90
NATAL AEROPORTO 825990 —5.92 —35.25 0A 1306 51
PORTO ALEGRE (AERO) 839710 —30.00 —51.18 2A 1353 53
PORTO VELHO (AERO) 828240 —8.77 —63.92 0A 2230 88
RECIFE (AEROPORTO) 828990 —8.07 —34.85 0A 2353 93
RIO BRANCO 829170 —10.00 —67.80 1A 1451 57
RIO DE JANEIRO (AERO) 837550 —22.90 —43.17 1A 1154 45
SALVADOR (AEROPORTO) 832480 —12.90 —38.33 0A 1804 71
SANTAREM-AEROPORTO 822440 —2.43 —54.72 0A 2312 91
SAO LUIZ (AEROPORTO) 822810 —2.60 —44.23 0A 1982 78
SAO PAULO (AEROPORTO) 837800 —23.62 —46.65 2A 1511 59
TERESINA (AEROPORTO) 825790 —5.05 —42.82 0A 1392 55
UBERABA 835760 —19.78 —47.97 2A 1631 64
VITORIA (AEROPORTO) 836490 —20.27 —40.28 1A 1289 51
British Indian Ocean Territory (IOT)
DIEGO GARCIA NAF 619670 —7.30 72.40 0A 2026 80
Brunei (BRN)
BRUNEI AIRPORT 963150 4.93 114.93 0A 2922 115
Bulgaria (BGR)
BOTEV VRAH (TOP/SOMMET) 156270 42.67 24.83 7 884 35
BURGAS 156550 42.48 27.48 4A 588 23
CHERNI VRAH (TOP/SOMMET) 156130 42.58 23.27 7 775 30
CHIRPAN 156350 42.20 25.33 4A 589 23
ELHOVO 156420 42.18 26.57 4A 541 21
IVAILO 156280 42.22 24.33 4A 515 20
KALIAKPA 155620 43.37 28.47 4A 422 17
KURDJALI 157300 41.65 25.37 4A 633 25
KUSTENDIL 156010 42.27 22.77 4A 668 26
LOM 155110 43.82 23.25 4A 553 22
LOVETCH 155250 43.13 24.72 4A 663 26
MOURGASH 156000 42.83 23.67 7 714 28
MUSSALA (TOP/SOMMET) 156150 42.18 23.58 8 971 38
PLEVEN 155260 43.42 24.60 4A 584 23
PLOVDIV 156250 42.13 24.75 4A 518 20
RAZGRAD 155490 43.52 26.53 4A 582 23
ROUSSE 155350 43.85 25.95 4A 583 23
SANDANSKI 157120 41.52 23.27 4A 539 21
SHABLA 155610 43.53 28.53 4A 408 16
SHUMEN 155440 43.27 26.93 4A 559 22
SLIVEN 156400 42.67 26.32 4A 559 22
SOFIA (OBSERV.) 156140 42.65 23.38 5A 612 24
SVICHTOV 155330 43.62 25.35 4A 534 21
SVILENGRAD 157410 41.77 26.20 4A 577 23
VARNA