Reference Title
Air Conditioning, Heating and Refrigeration Institute (AHRI)
2311 Wilson Blvd., Arlington, VA 22201
AHRI 210/240-2017 Unitary Air Conditioning and Air-Source Heat Pump Equipment (applicable before 1/1/2023)
AHRI 210/240-2023 Unitary Air Conditioning and Air-Source Heat Pump Equipment (applicable on or after 1/1/2023)
AHRI 310/380-2017 Packaged Terminal Air-Conditioners and Heat Pumps
AHRI 340/360-2019 Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment
AHRI 365-2009 Commercial and Industrial Unitary Air-Conditioning Condensing Units
ANSI/AHRI 390-2003 Performance Rating of Single Packaged Vertical Air-Conditioners and Heat Pumps
ANSI/AHRI 400-2015 Performance Rating of Liquid-to-Liquid Heat Exchangers
ANSI/AHRI 460-2005 Remote Mechanical Draft Air Cooled Refrigerant Condensers
AHRI 550/590-2018 Performance Rating of Water-Chilling and Heat-Pump Water-Heating Packages Using the Vapor Compression Cycle
AHRI 560-2018 Absorption Water Chilling and Water Heating Packages
ANSI/AHRI Standard 910-2014 Performance Rating of Indoor Pool Dehumidifiers
ANSI/AHRI Standard 920-2015 Performance Rating of DX-Dedicated Outdoor Air System Units
ANSI/AHRI 1160-2014 Performance Rating of Heat Pump Pool Heaters
ANSI/AHRI 1200-2013 Performance Rating of Commercial Refrigerated Display Merchandisers and Storage Cabinets
ANSI/AHRI 1230-2014 with Addendum 1 Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-Conditioning and Heat Pump Equipment
AHRI Standard 1250-2014 Performance Rating of Walk-In Coolers and Freezers
AHRI Standard 1360-2017 Performance Rating of Computer and Data Processing Room Air Conditioners
BTS 2000 rEV 06.07 Testing Standard Method to Determine Efficiency of Commercial Space Heating Boilers
Air Movement and Control Association International (AMCA)
30 West University Drive, Arlington Heights, IL 60004-1806
ANSI/AMCA 208-18 Calculation of the Fan Energy Index
ANSI/AMCA Standard 230-15 Laboratory Methods of Testing Air Circulating Fans for Rating and Certification
ANSI/AMCA Standard 500-D-18 Laboratory Methods of Testing Dampers for Rating
American Architectural Manufacturers Association (AAMA)
1900 E. Golf Rd, Suite 1250, Schaumburg, IL 60173-4268

Canadian Standards Association (CSA)
78 Rexdale Blvd., Toronto, On, Canada M9W 1R3

Window and Door Manufacturers Association (WDMA)
2025 M Street, NW, Suite 800, Washington, DC 20036
AAMA/WDMA/CSA 101/I.S.2/A440-17 NAFS-North American Fenestration Standard/Specification for Windows, Doors, and Skylights
American National Standards Institute (ANSI)
1899 L Street, NW, 11th Floor, Washington, DC 20036
ANSI Z21.10.3-2017/CSA 4.3-2017 Gas-Fired Water Heaters, Volume III, Storage Water Heaters with Input Ratings Above 75,000 Btu Per Hour, Circulating and Instantaneous
ANSI Z21.47-2016/CSA 2.3-2016 Gas-Fired Central Furnaces
ANSI Z83.8-2016/CSA 2.6-2016 Gas Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters And Gas-Fired Duct Furnaces
American Society of Mechanical Engineers (ASME)
Two Park Avenue, New York, NY 10016-5990
ASME A17.1-2016/CSA B44-16 Safety Code for Elevators and Escalators
ASHRAE
1791 Tullie Circle, NE, Atlanta, GA 30329
ANSI/ASHRAE Standard 55-2017 Thermal Environmental Conditions for Human Occupancy
ANSI/ASHRAE Standard 62.1-2016
(with Addenda b, c, d, e, f, g, h, j, k, o, q, r, u, v, w, z)
Ventilation for Acceptable Indoor Air Quality
ANSI/ASHRAE/IESNA Standard 90.1-2007 Energy Standard for Buildings Except Low-Rise Residential Buildings
ANSI/ASHRAE/IESNA Standard 90.1-2010 Energy Standard for Buildings Except Low-Rise Residential Buildings
ANSI/ASHRAE/IESNA Standard 90.1-2013 Energy Standard for Buildings Except Low-Rise Residential Buildings
ANSI/ASHRAE Standard 90.4-2016 (with Addenda a and b) Energy Standard for Data Centers
ANSI/ASHRAE Standard 127-2012 Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners
ANSI/ASHRAE Standard 140-2017 Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs
ANSI/ASHRAE Standard 154-2016 Ventilation for Commercial Cooking Operations
ANSI/ASHRAE Standard 169-2013 Climatic Data for Building Design Standards
ANSI/ASHRAE/ASHE Standard 170-2017 Ventilation of Health Care Facilities
ANSI/ASHRAE/ACCA Standard 183-2007 (RA 2017) Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings
Association of Home Appliance Manufacturers (AHAM)
1111 19th Street NW, Suite 402, Washington, DC 20036
ANSI/AHAM HRF-1-2016 Energy and Internal Volume of Refrigerating Appliances
ANSI/AHAM RAC-1-R2015 Room Air Conditioners
ASTM International
100 Barr Harbor Dr., West Conshohocken, PA 19428-2959
ASTM C90-16A Standard Specification for Loadbearing Concrete Masonry Units
ASTM C177-13 Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmittance Properties by Means of the Guarded-Hot-Plate Apparatus
ASTM C272/C272M-18 Standard Test Method for Water Absorption of Core Materials for Sandwich Constructions
ASTM C518-17 Standard Test Method for Steady-State Thermal Transmittance Properties by Means of the Heat Flow Meter Apparatus
ASTM C835-06 (2013) e1 Standard Test Method for Total Hemispherical Emittance of Surfaces up to 1400°C
ASTM C1224-15 Standard Specification for Reflective Insulation for Building Applications
ASTM C1363-11 Standard Test Method for the Thermal Performance of Building Assemblies by Means of a Hot Box Apparatus
ASTM D1003-13 Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics
ASTM E283-04 (2012) Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
ASTM E779-2018 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
ASTM E972-96 (2013) Standard Test Method for Solar Photometric Transmittance of Sheet Materials Using Sunlight
ASTM E1677-11 Standard Specification for an Air Retarder (AR) Material or System for Low-Rise Framed Building Walls
ASTM E1680-16 Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems
ASTM E1827-2017 Standard Test Methods for Determining Airtightness of Buildings Using an Orifice Blower Door
ASTM E1980-11 Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low Sloped Opaque Surfaces
ASTM E2178-13 Standard Test Method for Air Permeance of Building Materials
ASTM E2357-18 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies
Cool Roof Rating Council (CRRC)
2435 N. Lombard St.
Portland, OR 97217
United States
ANSI/CRRC S100-2016 Standard Test Methods for Determining Radiative Properties of Materials
Cooling Technology Institute (CTI)
3845 Cypress Creek Parkway, Suite 420, Houston, TX 77068; P.O. Box 681807
CTI ATC-105 (19) Acceptance Test Code for Water Cooling Towers
CTI ATC-105DS (18) Acceptance Test Code for Dry Fluid Coolers
CTI ATC-105S (11) Acceptance Test Code for Closed-Circuit Cooling Towers
CTI ATC-106 (11) Acceptance Test Code for Mechanical Draft Evaporative Vapor Condensers
CTI STD-201 RS (17) Performance Rating of Evaporative Heat Rejection Equipment
Door and Access Systems Manufacturers Association (DASMA)
1300 Sumner Avenue, Cleveland, OH 44115-2851
ANSI/DASMA 105-2017 Test Method for Thermal Transmittance and Air Infiltration of Garage Doors
Illuminating Engineering Society (IES)
120 Wall street, Floor 17, New York, NY 10005-4001
ANSI/IES RP-28-2016 Lighting and the Visual Environment for Senior Living
International Organization for Standardization (ISO) ISO Central Secretariat BIBC II
Chemin de Blandonnet 8, CP 401, 1214 Vernier, Geneva, Switzerland
ISO 9050 (2003) Glass in Building—Determination of Light Transmittance, Solar Direct Transmittance, Total Solar Energy Transmittance, Ultraviolet Transmittance and Related Glazing Factors
ANSI/AHRI/ASHRAE/ISO 13256-1:1998 (R2015) Water-Source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-Air and Brine-to-Air Heat Pumps
ANSI/AHRI/ASHRAE/ISO 13256-2:1998 (R2015) Water-Source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-Water and Brine-to-Water Heat Pumps
ISO 25745-2:2015 Energy Performance of Lifts, Escalators and Moving Walks—Part 2: Energy Calculation and Classification for Lifts (Elevators)
National Electrical Manufacturers Association (NEMA)
1300 N. 17th Street, Suite 900, Arlington, VA 22209
ANSI/NEMA MG 1-2016 Motors and Generators
National Fenestration Rating Council (NFRC)
6305 Ivy Lane, Suite 140, Greenbelt, MD 20770-6323
ANSI/NFRC 100-2017 Procedure for Determining Fenestration Product U-Factors
ANSI/NFRC 200-2017 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
NFRC 203-2017 Procedure for Determining Visible Transmittance of Tubular Daylighting Devices
NFRC 300-2017 Test Method for Determining the Solar Optical Properties of Glazing Materials and Systems
NFRC 301-2017 Test Method for Emittance of Specular Surfaces Using Spectrometric Measurements
ANSI/NFRC 400-2017 Procedure for Determining Fenestration Product Air Leakage
National Fire Protection Association (NFPA)
1 Battery March Park, P.O. Box 9101, Quincy, MA 02269-9101
NFPA 70-2014 National Electric Code
NFPA 96-2017 Ventilation Control and Fire Protection of Commercial Cooking Operations
Telecommunications Industry Association (TIA) 1320 North Courthouse Road, Suite 200
ANSI/TIA-942-REV A, July 12, 2017 Telecommunication Infrastructure Standard for Data Centers
Underwriters Laboratories, Inc. (UL)
333 Pfingsten Rd., Northbrook, IL 60062
UL 181A-2013 Closure Systems for Use with Rigid Air Ducts and Air Connectors
UL 181B-2013 Closure Systems for Use with Flexible Air Ducts and Air Connectors
UL 727-2018 UL Standard for Safety—Oil Fired Central Furnaces
UL 731-2018 UL Standard for Safety—Oil-Fired Unit Heaters
U.S. Department of Defense
3010 Defense Pentagon, Washington, DC 20301
MIL-P-17639F (1996) Pumps, Centrifugal, Miscellaneous Service, Naval Shipboard Use
MIL-P-17840C (1986) Pumps, Centrifugal, Close-Coupled, Navy Standard (For Surface Ship Application)
MIL-P-17881D (1972) Pumps, Centrifugal, Boiler Feed (Multi-Stage)
MIL-P-18472 (1989) Pumps, Centrifugal, Condensate, Feed Booster, Waste Heat Boiler, and Distilling Plant
MIL-P-18682D Pump, Centrifugal, Main Condenser Circulating, Naval Shipboard
U.S. Department of Energy (DOE)
1000 Independence Avenue, SW, Washington, DC 20585
10 CFR Part 430, App N Uniform Test Method for Measuring the Energy Consumption of Furnaces
10 CFR Part 431.304 Uniform Test Method for the Measurement of Energy Consumption of Walk-In Coolers and Walk-In Freezers
10 CFR 431 Subpart K, App A Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers
10 CFR Part 431, Subpart B, App B Uniform Test Method for Measuring Nominal Full-Load Efficiency of Electric Motors
10 CFR Part 431, Subpart Y Pumps: Definitions, Energy Conservation Standards, and Uniform Test Method of the Measurement of Energy Consumption of Pumps
42 USC 6831, et seq., Public Law 102-486 Energy Policy Act of 1992, EPACT 2005, and EISA 2007
U.S. Security and Exchange Commission (SEC)
100 F Street, NE, Washington, DC 20549
The Interagency Paper on Sound Practices to Strengthen the Resilience of the US Financial System The Interagency Paper on Sound Practices to Strengthen the Resilience of the US Financial System, April 7, 2003
U.S. Nuclear Regulatory Commission One White Flint North
11555 Rockville Pike
Rockville, MD 20852-2738
10 CFR Part 50 Domestic Licensing of Production and Utilization Facilities
Linked Resources
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Code Compare
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Bookmarks
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Amendment Styling
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More