ADOPTS WITH AMENDMENTS:

International Residential Code 2018 (IRC 2018)

Part I — Administrative

Part II — Definitions

Part III — Building Planning and Construction

Part IV — Energy Conservation

Part V — Mechanical

Part VI — Fuel Gas

Part VII — Plumbing

Part VIII — Electrical

Part IX — Referenced Standards

Heads up: There are no amended sections in this chapter.
User note:
About this chapter: The one- and two-family dwelling code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials, products and methods of construction. Chapter 44 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.
AAMA
American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg IL60173
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standards/Specifications for Windows, Doors and Skylights
450—10
Voluntary Performance Rating Method for Mulled Fenestration Assemblies
506—16
Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products
711—13
Voluntary Specification for Self-adhering Flashing Used for Installation of Exterior Wall Fenestration Products
712—14
Voluntary Specification for Mechanically Attached Flexible Flashing
714—15
Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive Seal around Exterior Wall Openings in Buildings
AAMA/NPEA/NSA 2100—12
Specifications for Sunrooms
ACCA
Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA22206
Manual D—2016
Residential Duct Systems
Manual J—2016
Residential Load Calculation—Eighth Edition
Manual S—2014
Residential Equipment Selection
ACI
American Concrete Institute
38800 Country Club Drive
Farmington Hills MI48331
332—14
Residential Code Requirements for Structural Concrete
AISI
American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington DC20001
AISI S100—16
North American Specification for the Design of Cold-formed Steel Structural Members, 2016
AISI S220—15
North American Standard for Cold-formed Steel Framing—Nonstructural Members, 2015
AISI S230—15
Standard for Cold-formed Steel Framing—Prescriptive Method for One- and Two-family Dwellings, 2015
AISI S240—15
North American Standard for Cold-Formed Steel Structural Framing
AMCA
Air Movement and Control Association International
30 West University Drive
Arlington Heights IL60004
ANSI/AMCA 210-ANSI/ASHRAE 51—07
Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
ANCE
Association of the Electric Sector
Av. Lázaro Cardenas No. 869
Col. Nueva Industrial Vallejo
C.P. 07700 México D.F.
NMX-J-521/2-40-ANCE—2014/CAN/CSA-22.2 No. 60335-2-40—12/UL 60335-2-40
Safety of Household and Similar Electric Appliances, Part 2-40: Particular Requirements for Heat Pumps, Air-Conditioners and Dehumidifiers
ANSI
American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY10036
A108.1A—16
Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar
A108.1B—99
Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
A108.4—99
Installation of Ceramic Tile with Organic Adhesives or Water-Cleanable Tile-setting Epoxy Adhesive
A108.5—99
Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex Portland Cement Mortar
A108.6—99
Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy
A108.11—99
Interior Installation of Cementitious Backer Units
ANSI 117—2015
Standard Specifications for Structural Glued Laminated Timber of Softwood Species
A118.1—16
American National Standard Specifications for Dry-set Portland Cement Mortar
A118.3—13
American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy, and Water-cleanable Tile-setting Epoxy Adhesive
A118.4—16
American National Standard Specifications for Modified Dry-Set Cement Mortar
A118.10—99
Specification for Load-bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation
A136.1—08
American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile
A137.1—17
American National Standard Specifications for Ceramic Tile
LC1/CSA 6.26—13
Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST)
LC4/CSA 6.32—12
Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems
Z21.1—2010
Household Cooking Gas Appliances
Z21.5.1/CSA 7.1—14
Gas Clothes Dryers—Volume I—Type I Clothes Dryers
Z21.8—94 (R2002)
Installation of Domestic Gas Conversion Burners
Z21.10.1/CSA 4.1—12
Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings of 75,000 Btu per hour or Less
Z21.10.3/CSA 4.3—11
Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings above 75,000 Btu per hour, Circulating and Instantaneous
Z21.11.2—11
Gas-fired Room Heaters—Volume II—Unvented Room Heaters
Z21.13/CSA 4.9—11
Gas-fired Low-pressure Steam and Hot Water Boilers
Z21.15/CSA 9.1—09
Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves
Z21.22—99 (R2003)
Relief Valves for Hot Water Supply Systems—with Addenda Z21.22a—2000 (R2003) and 21.22b—2001 (R2003)
Z21.24/CSA 6.10—06
Connectors for Gas Appliances
Z21.40.1/CSA 2.91—96 (R2011)
Gas-fired, Heat-activated Air-conditioning and Heat Pump Appliances
Z21.40.2/CSA 2.92—96 (R2011)
Air-conditioning and Heat Pump Appliances (Thermal Combustion)
Z21.42—2014
Gas-fired Illuminating Appliances
Z21.47/CSA 2.3—12
Gas-fired Central Furnaces
Z21.50/CSA 2.22—16
Vented Gas Fireplaces
Z21.54—2009
Gas Hose Connectors for Portable Outdoor Gas-fired Appliances
Z21.56/CSA 4.7—17
Gas-fired Pool Heaters
Z21.58—95/CSA 1.6—13
Outdoor Cooking Gas Appliances
Z21.60/CSA 2.26—12
Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces
Z21.69/CSA 6.16—09
Connectors for Movable Gas Appliances
Z21.75/CSA 6.27—07
Connectors for Outdoor Gas Appliances and Manufactured Homes
Z21.80/CSA 6.22—11
Line Pressure Regulators
ANSI/CSA FC 1—12
Stationary Fuel Cell Power Systems
Z21.84—12
Manually Listed, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces
Z21.86/CSA 2.32—08
Gas-fired Vented Space Heating Appliances
Z21.88/CSA 2.33—16
Vented Gas Fireplace Heaters
Z21.91—07
Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters
Z21.93/CSA 6.30—13
Excess Flow Valves for Natural and LP Gas with Pressures up to 5 psig
Z21.97—12
Outdoor Decorative Appliances
Z83.6—90 (R1998)
Gas-fired Infrared Heaters
Z83.8/CSA 2.6—09
Gas-fired Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces
Z83.19—01 (R2009)
Gas-fuel High-intensity Infrared Heaters
Z83.20—08
Gas-fired Low-intensity Infared Heaters Outdoor Decorative Appliances
Z97.1—2015
Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test
APA
APA—The Engineered Wood Association
7011 South 19th
Tacoma WA98466
ANSI/A190.1—2017
Structural Glued-laminated Timber
ANSI/APA PRP 210—2014
Standard for Performance-rated Engineered Wood Siding
ANSI/APA PRG 320—2017
Standard for Performance-rated Cross Laminated Timber
ANSI/APA PRR 410—2016
Standard for Performance-rated Engineered Wood Rim Boards
ANSI/APA PRS 610.1—2013
Standard for Performance-Rated Structural Insulated Panels in Wall Applications
APA E30—15
Engineered Wood Construction Guide
APSP
The Association of Pool & Spa Professionals
211 Eisenhower Avenue, Suite 500
Alexander VA22314
ANSI/APSP/ICC 14—2014
American National Standard for Portable Electric Spa Energy Efficiency
ANSI/APSP/ICC 15a—2011
American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Appendix A Approved January 9, 2013
ASCE/SEI
American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA20191-4400
24—14
Flood-resistant Design and Construction
32—01
Design and Construction of Frost-protected Shallow Foundations
ASHRAE
ASHRAE
1791 Tullie Circle NE
Atlanta GA30329
ASHRAE—2001
2001 ASHRAE Handbook of Fundamentals
ASHRAE—2017
ASHRAE Handbook of Fundamentals
ASHRAE 193—2010(RA 2014)
Method of Test for Determining Air Tightness of HVAC Equipment
34—2016
Designation and Safety Classification of Refrigerants
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York NY10016-5990
ASME A17.1—2016/CSA B44—16
Safety Code for Elevators and Escalators
A18.1—2014
Safety Standard for Platforms and Stairway Chair Lifts
A112.1.2—2012
Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water Connected Receptors)
A112.1.3—2000 (Reaffirmed 2015)
Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances
A112.3.1—2007(R2012)
Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground
A112.3.4—2013/CSA B45.9—13
Macerating Toilet Systems and Related Components
A112.4.1—2009
Water Heater Relief Valve Drain Tubes
ASME A112.4.2—2015/CSA B45.16—15
Water-closet Personal Hygiene Devices
A112.4.3—1999 (R2010)
Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System
A112.4.14—2004 (R2016)
Manually Operated, Quarter-turn Shutoff Valves for Use in Plumbing Systems
A112.6.2—2000 (R2016)
Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks
A112.6.3—2001 (R2016)
Floor and Trench Drains
A112.14.1—03(2012)
A112.18.2—2015/CSA B125.2—2015
A112.18.3—2002(R2012)
Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings
A112.18.6—2017/CSA B125.6—17
Flexible Water Connectors
A112.19.1—2013/CSA B45.2—2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
A112.19.2—2013/CSA B45.1—2013
A112.19.3—2008/CSA B45.4—08 (R2013)
Stainless Steel Plumbing Fixtures
A112.19.5—2017/CSA B45.15—2017
Flush Valves and Spuds for Water-closets, Urinals and Tanks
A112.19.7—2017/CSA B45.10—2017
Hydromassage Bathtub Systems
A112.19.12—2014
Wall-mounted and Pedestal-mounted, Adjustable, Elevating, Tilting, and Pivoting Lavatory and Sink, and Shampoo Bowl Carrier Systems and Drain Waste Systems
A112.19.14—2013
Six-Liter Water Closets Equipped with Dual Flushing Device
A112.19.15—2012
Bathtub/Whirlpool Bathtubs with Pressure-sealed Doors
A112.36.2m—1991 (R2012)
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—15
Anti-Siphon Fill Valves
B1.20.1—2013
Pipe Threads, General-purpose (Inch)
B16.3—2016
Malleable-iron-threaded Fittings, 150 and 300
B16.4—2016
Gray-iron-threaded Fittings
B16.9—2012
Factory-made, Wrought-steel Buttwelding Fittings
B16.11—2016
Forged Fittings, Socket-welding and Threaded
B16.12—2009 (R2014)
Cast-iron-threaded Drainage Fittings
B16.15—2013
Cast-Alloy-threaded Fittings: Classes 125 and 250
B16.18—2012
Cast-copper-alloy Solder Joint Pressure Fittings
B16.22—2013
Wrought-copper and Copper-alloy Solder Joint Pressure Fittings
B16.23—2016
Cast-copper-alloy Solder Joint Drainage Fittings (DWV)
B16.26—2016
Cast-copper-alloy Fittings for Flared Copper Tubes
B16.28—1994
Wrought-steel Buttwelding Short Radius Elbows and Returns
B16.29—2012
Wrought-copper and Wrought-copper-alloy Solder Joint Drainage Fittings (DWV)
B16.33—2012
Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)
B16.34—2015
Valves—Flanged, Threaded and Welding End
B16.44—2012
Manually Operated Metallic Gas Valves for Use in Above-ground Piping Systems up to 5 psi
B16.51—2013
Copper and Copper Alloy Press-Connect Pressure Fittings
B36.10M—2004(R2015)
Welded and Seamless Wrought-steel Pipe
BPVC—2015
ASME Boiler and Pressure Vessel Code (Sections I, II, IV, V, VI and VIII)
CSD-1—2016
Controls and Safety Devices for Automatically Fired Boilers
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.70—15
Performance Requirements for Water-temperature-limiting Devices
ASSE
ASSE International
18927 Hickory Creek Drive, Suite 220
Mokena IL60448
1001—2016
Performance Requirements for Atmospheric-type Vacuum Breakers
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—15
Anti-Siphon Fill Valves
1003—2009
Performance Requirements for Water-pressure-reducing Valves for Domestic Water Distribution Systems
1008—2006
Performance Requirements for Plumbing Aspects of Residential Food Waste Disposer Units
1010—2004
Performance Requirements for Water Hammer Arresters
1011—2016
Performance Requirements for Hose Connection Vacuum Breakers
1012—2009
Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent
1013—2017
Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Principle Fire Protection Backflow Preventers
1015—2017
Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
1017—2010
Performance Requirements for Temperature-actuated Mixing Valves for Hot Water Distribution Systems
1018—2017
Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied
1019—2016
Performance Requirements for Freeze-resistant, Wall Hydrants, Vacuum Breaker, Draining Types
1020—2004
Performance Requirements for Pressure Vacuum Breaker Assembly
1023—2016
Performance Requirements for Hot Water Dispensers, Household-storage-type—Electrical
1024—2016
Performance Requirements for Dual Check Backflow Preventers, Anti-siphon-type, Residential Applications
1035—2008
Performance Requirements for Laboratory Faucet Backflow Preventers
ASSE 1037—2015/ASME A112.1037—2015/CSA B125.37—15
Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures
1044—2010
Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types
1047—2017
Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
1048—2017
Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
1050—2009
Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
1051—2009
Performance Requirements for Individual and Branch-type Air Admittance Valves for Plumbing Drainage Systems
1052—2016
Performance Requirements for Hose Connection Backflow Preventers
1056—2013
Performance Requirements for Spill-resistant Vacuum Breakers
1060—2016
Performance Requirements for Outdoor Enclosures for Fluid-conveying Components
1061—2015
Performance Requirements for Push Fit Fittings
1062—2016
Performance Requirements for Temperature-actuated, Flow Reduction (TAFR) Valves for Individual Supply Fittings
1066—2016
Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.70—15
Performance Requirements for Water-temperature-limiting Devices
1072—2007
Performance Requirements for Barrier-type Floor Drain Trap Seal Protection Devices
ASTM
ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA19428
A36/A36M—14
Specification for Carbon Structural Steel
A53/A53M—12
Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless
A74—15
Specification for Cast-iron Soil Pipe and Fittings
A106/A106M—14
Specification for Seamless Carbon Steel Pipe for High-temperature Service
A123/A123M—15
Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
Table 507.2.3
A126—04(2014)
Gray Iron Castings for Valves, Flanges and Pipe Fittings
A153/A153M—09
Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware
A167—99(2009)
Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip
A240/A240M—15A
Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
A254—12
Specification for Copper Brazed Steel Tubing
A268—2010
Standard Specification for Seamless and Welded Ferritic and Martensitic Stainless Steel Tubing for General Service
A269—2015
Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service
A307—14
Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength
A312/A312M—15A
Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes
A463/A463M—15
Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process
A539—99
Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines
A563—15
Standard Specification for Carbon and Alloy Steel Nuts
A615/A615M—2015aE1
Specification for Deformed and Plain Carbon-steel Bars for Concrete Reinforcement
A641/A641M—09a(2014)
Specification for Zinc-coated (Galvanized) Carbon Steel Wire
A653/A653M—15
Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated (Galvannealed) by the Hot-dip Process
A706/A706M—15
Specification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A755/A755M—2015
Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted by the Coil-coating Process for Exterior Exposed Building Products
A778/A778M—15
Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products
A792/A792M—10(2015)
Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process
R505.2.2, R603.2.2, R608.5.2.3, R804.2.2, Table 905.10.3(2)
A875/A875M—13
Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process
A888—15
Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Application
A924/A924M—14
Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-dip Process
A996/A996M—15
Specifications for Rail-steel and Axle-steel Deformed Bars for Concrete Reinforcement
A1003/A1003M—15
Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members
B32—08(2014)
Specification for Solder Metal
B42—2015A
Specification for Seamless Copper Pipe, Standard Sizes
B43—15
Specification for Seamless Red Brass Pipe, Standard Sizes
B75/B75M—11
Specification for Seamless Copper Tube
B88—14
Specification for Seamless Copper Water Tube
B101—12
Specification for Lead-coated Copper Sheet and Strip for Building Construction
B135—10
Specification for Seamless Brass Tube
B209—14
Specification for Aluminum and Aluminum-alloy Sheet and Plate
Table 905.10.3(1)
B251—10
Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B302—12
Specification for Threadless Copper Pipe, Standard Sizes
B306—13
Specification for Copper Drainage Tube (DWV)
B370—12
Specification for Copper Sheet and Strip for Building Construction
B447—12a
Specification for Welded Copper Tube
B695—04(2009)
Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel
B813—10
Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube
B828—02(2010)
Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings
C4—04(2014)
Specification for Clay Drain Tile and Perforated Clay Drain Tile
C5—10
Specification for Quicklime for Structural Purposes
C14—15a
Specification for Non-reinforced Concrete Sewer, Storm Drain and Culvert Pipe
C22/C22M—2015
Specification for Gypsum
C27—98(2013)
Specification for Standard Classification of Fireclay and High-alumina Refractory Brick
C28/C28M—10(2015)
Specification for Gypsum Plasters
C33/C33M—13
Specification for Concrete Aggregates
C34—13
Specification for Structural Clay Load-bearing Wall Tile
C35/C35M—(2014)
Specification for Inorganic Aggregates for Use in Gypsum Plaster
C55—2014A
Specification for Concrete Building Brick
C56—13
Standard Specification for Structural Clay Nonloadbearing Tile
C59/C59M—00(2015)
Specification for Gypsum Casting Plaster and Molding Plaster
C61/C61M—00(2015)
Specification for Gypsum Keene's Cement
C62—13A
Standard Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)
C73—14
Specification for Calcium Silicate Face Brick (Sand Lime Brick)
C76—15A
Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe
C90—14
Specification for Load-bearing Concrete Masonry Units
C91/C91M—12
Specification for Masonry Cement
C94/C94M—15A
Standard Specification for Ready-mixed Concrete
C126—15
Standard Specification for Ceramic Glazed Structural Clay Facing Tile, Facing Brick, and Solid Masonry Units
C129—14A
Specification for Nonload-bearing Concrete Masonry Units
C143/C143M—15
Test Method for Slump of Hydraulic Cement Concrete
C145—85
Specification for Solid Load-bearing Concrete Masonry Units
C150/C150M—15
Specification for Portland Cement
C199—84(2011)
Test Method for Pier Test for Refractory Mortar
C203—05a(2012)
Standard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal Insulation
C207—06(2011)
Specification for Hydrated Lime for Masonry Purposes
C208—12
Specification for Cellulosic Fiber Insulating Board
C212—14
Standard Specification for Structural Clay Facing Tile
C216—15
Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)
C270—14A
Specification for Mortar for Unit Masonry
C315—07(2011)
Specification for Clay Flue Liners and Chimney Pots
C406/C406M—2015
Specifications for Roofing Slate
C411—11
Test Method for Hot-surface Performance of High-temperature Thermal Insulation
C425—04(2013)
Specification for Compression Joints for Vitrified Clay Pipe and Fittings
C443—12
Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets
C475/C475M—15
Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard
C476—10
Specification for Grout for Masonry
C503/C503M—2010
Standard Specification for Marble Dimension Stone
C514—04(2014)
Specification for Nails for the Application of Gypsum Wallboard
C552—15
Standard Specification for Cellular Glass Thermal Insulation
C557—03(2009)e01
Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing
C564—14
Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings
C568/C568M—2010
Standard Specification for Limestone Dimension Stone
C578—15
Specification for Rigid, Cellular Polystyrene Thermal Insulation
C587—04(2014)
Specification for Gypsum Veneer Plaster
C595/C595M—14E1
Specification for Blended Hydraulic Cements
C615/C615M—11
Standard Specification for Granite Dimension Stone
C616/C616M—10
Standard Specification for Quartz-based Dimension Stone
C629/C629M—10
Standard Specification for Slate Dimension Stone
C631—09(2014)
Specification for Bonding Compounds for Interior Gypsum Plastering
C645—14
Specification for Nonstructural Steel Framing Members
C652—15
Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)
C685/C685M—14
Specification for Concrete Made by Volumetric Batching and Continuous Mixing
C700—13
Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength and Perforated
C726—12
Standard Specification for Mineral Wool Roof Insulation Board
C728—15
Standard Specification for Perlite Thermal Insulation Board
C744—14
Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units
C836/C836M—15
Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course
C841—03(2013)
Standard Specification for Installation of Interior Lathing and Furring
C842—05(2015)
Standard Specification for Application of Interior Gypsum Plaster
C843—99(2012)
Specification for Application of Gypsum Veneer Plaster
C844—2015
Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster
C847—14A
Specification for Metal Lath
C887—13
Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar
C897—15
Specification for Aggregate for Job-mixed Portland Cement-based Plasters
C920—14A
Standard Specification for Elastomeric Joint Sealants
C926—15B
Specification for Application of Portland Cement-based Plaster
C933—14
Specification for Welded Wire Lath
C946—10
Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls
C954—15
Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or to 0.112 in. (2.84 mm) in Thickness
C957/C957M—15
Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing Membrane for Use with Integral Wearing Surface
C1002—14
Specification for Steel Self-piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs
C1029—15
Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation
C1032—14
Specification for Woven Wire Plaster Base
C1047—14a
Specification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
C1063—15A
Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster
C1088—14
Standard Specification for Thin Veneer Brick Units Made from Clay or Shale
C1107/C1107M—14A
Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)
C1116/C116M—10(2015)
Standard Specification for Fiber-reinforced Concrete and Shotcrete
C1157—11/C1157M—11
Standard Performance Specification for Hydraulic Cement
C1167—11
Specification for Clay Roof Tiles
C1173—10(2014)
Specification for Flexible Transition Couplings for Underground Piping Systems
C1177/C1177M—13
Specification for Glass Mat Gypsum Substrate for Use as Sheathing
R702.3.1, Table 906.2
C1178/C1178M—13
Specification for Glass Mat Water-resistant Gypsum Backing Panel
C1186—08(2012)
Specification for Flat Fiber Cement Sheets
C1261—13
Specification for Firebox Brick for Residential Fireplaces
C1277—15
Specification for Shielded Couplings Joining Hubless Cast Iron Soil Pipe and Fittings
C1278/C1278M—07a(2011)
Specification for Fiber-reinforced Gypsum Panels
C1283—11
Practice for Installing Clay Flue Lining
C1288—14
Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets
C1289—15
Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
C1325—14
Standard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets Backer Units
C1328/C1328M—12
Specification for Plastic (Stucco) Cement
C1363—11
The Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
C1364—10B
Standard Specification for Architectural Cast Stone
C1396/C1396M—2014A
Specification for Gypsum Board
C1405—15
Standard Specification for Glazed Brick (Single Fired, Brick Units)
C1440—08(2013)
Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
C1460—2012
Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground
C1461—08(2013)
Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use
C1492—03(2009)
Specification for Concrete Roof Tile
C1513—2013
Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections
C1540—15
Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings
C1634—15
Standard Specification for Concrete Facing Brick
C1658/C1658M—13
Standard Specification for Glass Mat Gypsum Panels
C1668—13a
Standard Specification for Externally Applied Reflective Insulation Systems on Rigid Duct in Heating, Ventilation, and Air Conditioning (HVAC) Systems
C1670/1670M—16
Standard Specification for Adhered Manufactured Stone Masonry Veneer Units
C1691—11
Standard Specification for Unreinforced Autoclaved Aerated Concrete (AAC) Masonry Units
C1693—11
Standard Specification for Autoclaved Aerated Concrete (AAC)
C1766—13
Standard Specification for Factory-Laminated Gypsum Panel Products
D41/D41M—2011
Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing
D43/D43M—2000(2012)E1
Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
D226/D226M—09
Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing
D227/D227M—03(2011)e1
Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing
D312/D321M—15
Specification for Asphalt Used in Roofing
D422—63(2007)E2
Test Method for Particle-size Analysis of Soils
D449/D449M—03(2014)E1
Specification for Asphalt Used in Dampproofing and Waterproofing
D450/D450M—07(2013)E1
Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing
D1227—13
Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
D1248—12
Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable
D1527—99(2005)
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1693—15
Test Method for Environmental Stress-cracking of Ethylene Plastics
D1784—11
Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
D1785—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
D1863/D1863M—05(2011)e1
Specification for Mineral Aggregate Used in Built-up Roofs
D1869—15
Specification for Rubber Rings for Fiber-Reinforced Cement Pipe
D1970/D1970M—2015A
Specification for Self-adhering Polymer Modified Bitumen Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection
D2104—03
Specification for Polyethylene (PE) Plastic Pipe, Schedule 40
D2178/D2178M—15
Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
D2235—04(2011)
Specification for Solvent Cement for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe and Fittings
D2239—12A
Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter
D2241—15
Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)
D2282—99(2005)
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (SDR-PR)
D2412—11
Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading
D2447—03
Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on Outside Diameter
D2464—15
Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2466—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
D2467—15
Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2468—96a
Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe Fittings, Schedule 40
D2513—2014e1
Specification for Gas Pressure Pipe, Tubing and Fittings
D2564—12
Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems
D2609—15
Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe
D2626/D2626M—04 (2012)e1
Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing
D2657—07
Standard Practice for Heat Fusion-joining of Polyolefin Pipe Fittings
D2661—14
Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings
D2665—14
Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste and Vent Pipe and Fittings
D2672—14
Specification for Joints for IPS PVC Pipe Using Solvent Cement
D2683—14
Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
D2729—11
Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D2737—2012A
Specification for Polyethylene (PE) Plastic Tubing
D2751—05
Specification for Acrylonitrile-butadiene-styrene (ABS) Sewer Pipe and Fittings
D2822/D2822M—05(2011)e1
Specification for Asphalt Roof Cement, Asbestos Containing
D2823/D2823M—05(2011)e1
Specification for Asphalt Roof Coatings, Asbestos Containing
D2824/D2824M—2013
Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos
D2846/D2846M—14
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems
D2855—96(2010)
Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings
D2898—10
Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing
D2949—10
Specification for 3.25-in. Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste and Vent Pipe and Fittings
D3019—08
Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered
D3034—14a
Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D3035—15
Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On Controlled Outside Diameter
D3138—04(2011)
Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly (Vinyl Chloride) (PVC) Non-Pressure Piping Components
D3161/D3161M—15
Test Method for Wind-Resistance of Steep Slope Roofing Products (Fan Induced Method)
D3201/D3201M—2013
Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products
D3212—07(2013)
Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
D3261—12E1
Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing
D3309—96a(2002)
Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution System
D3311—11
Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns
D3350—14
Specification for Polyethylene Plastic Pipe and Fitting Materials
D3462/D3462M—10A
Specification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral Granules
D3468/D3468M—99(2013)E1
Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing
D3679—13
Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding
D3737—2012
Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)
D3747—79(2007)
Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation
D3909/D3909M—14
Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules
D4022/D4022M—2007(2012)e1
Specification for Coal Tar Roof Cement, Asbestos Containing
D4068—15
Specification for Chlorinated Polyethylene (CPE) Sheeting for Concealed Water Containment Membrane
D4318—10E1
Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils
D4434/D4434M—12
Specification for Poly (Vinyl Chloride) Sheet Roofing
D4479/D4479M—07(2012)e1
Specification for Asphalt Roof Coatings—asbestos-free
D4551—12
Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane
D4586/D4586M—07(2012)e1
Specification for Asphalt Roof Cemen—asbestos-free
D4601/D4601M—04(2012)e1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
D4637/D4637M—14E1
Specification for EPDM Sheet Used in Single-ply Roof Membrane
D4829—11
Test Method for Expansion Index of Soils
D4869/D4869M—15
Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing
D4897/D4897M—01(2009)
Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in Roofing
D4990—1997a(2013)
Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
D5019—07a
Specification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane
D5055—13E1
Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists
D5456—14B
Standard Specification for Evaluation of Structural Composite Lumber Products
D5516—09
Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood Exposed to the Elevated Temperatures
D5643/D5643M—06(2012)e1
Specification for Coal Tar Roof Cement Asbestos-free
D5664—10
Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures on Strength Properties of Fire-retardant-treated Lumber
D5665/D5665M—99a(2014)E1
Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing
D5726—98(2013)
Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing
D6083—05e01
Specification for Liquid-applied Acrylic Coating Used in Roofing
D6162/D6162M—2000a(2015)E1
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
D6163/D6163M—2000(2015)E1
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements
D6164/D6164M—11
Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements
D6222/D6222M—11
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcements
D6223/D6223M—02(2009)E1
Specification for Atactic Polypropylene (APP) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement
D6298—13
Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets with a Factory Applied Metal Surface
D6305—08(2015)E1
Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing
D6380/D6380—03(2013)E1
Standard Specification for Asphalt Roll Roofing (Organic Felt)
D6464—03a(2009)e1
Standard Specification for Expandable Foam Adhesives for Fastening Gypsum Wallboard to Wood Framing
D6694/D6694M—08(2013)E1
Standard Specification for Liquid-applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems
D6754/D6754M—10
Standard Specification for Ketone-ethylene-ester-based Sheet Roofing
D6757—2013
Specification for Underlayment Felt Containing Inorganic Fibers Used with Steep Slope Roofing
D6841—08
Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber
D6878/D6878M—13
Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing
D6947/D6947M—07(2013)E1
Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray Polyurethane Foam Roofing System
D7032—14
Standard Specification for Establishing Performance Ratings for Wood-plastic Composite Deck Boards and Guardrail Systems (Guards or Handrails)
R507.2.2, R507.2.2.1, 507.2.2.3, 507.2.2.4
D7158—D7158M—2016
Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method)
D7254—15
Standard Specification for Polypropylene (PP) siding
D7425/D7425M—13
Standard Specification for Spray Polyurethane Foam Used for Roofing Application
D7672—14
Standard Specification for Evaluating Structural Capacities of Rim Board Products and Assemblies
D7793—13
Standard Specification for Insulated Vinyl Siding
E84—2016
Standard Test Method for Surface Burning Characteristics of Building Materials
E96/E96M—2015
Test Method for Water Vapor Transmission of Materials
E108—2016
Test Methods for Fire Tests of Roof Coverings
E119—2016
Test Methods for Fire Tests of Building Construction and Materials
E136—2016
Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
R202, R302.11
E283—04(2012)
Test Method for Determining the Rate of Air Leakage through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences across the Specimen
R202, N1102.4.5
E330/E330M—14
Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference
E331—00(2009)
Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls by Uniform Static Air Pressure Difference
E779—10
Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
E814—2013A
Standard Test Method for Fire Tests of Penetration Firestop Systems
E970—14
Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
E1509—12
Standard Specification for Room Heaters, Pellet Fuel-burning Type
E1602—03(2010)e1
Guide for Construction of Solid Fuel Burning Masonry Heaters
E1827—11
Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door
E1886—13A
Test Method for Performance Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials
E1996—2014a
Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
E2178—2013
Standard Test Method for Air Permeance of Building Materials
R202
E2231—15
Standard Practice for Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics
E2273—03(2011)
Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and Finish Systems (EIFS) Clad Wall Assemblies
E2568—09e1
Standard Specification for PB Exterior Insulation and Finish Systems
E2570/E2570M—07(2014)E1
Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
E2634—11(2015)
Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems
F405—05
Specification for Corrugated Polyethylene (PE) Pipe and Fittings
F409—12
Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings
F437—15
Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F438—15
Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
F439—13
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F441/F441M—15
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80
F442/F442M—13E1
Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)
F477—14
Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
F493—14
Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
F628—12E1
Specification for Acrylonitrile-butadiene-styrene (ABS) Schedule 40 Plastic Drain, Waste and Vent Pipe with a Cellular Core
F656—15
Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride)(PVC) Plastic Pipe and Fittings
F714—13
Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F844—07a(2013)
Standard Specification for Washers, Steel, Plain (Flat), Unhardened for General Use
F876—15A
Specification for Cross-linked Polyethylene (PEX) Tubing
F877—2011A
Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems
F891—10
Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core
F1055—13
Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing
F1281—11
Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe
F1282—10
Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
F1412—09
Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage
F1488—14
Specification for Coextruded Composite Pipe
F1504—2014
Standard Specification for Folded Poly (Vinyl Chloride) (PVC) for Existing Sewer and Conduit Rehabilitation
P3011.4
F1554—15
Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength
F1667—15
Specification for Driven Fasteners, Nails, Spikes and Staples
F1807—15
Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F1866—13
Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
F1871—2011
Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
P3011.4
F1924—12
Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing
F1960—15
Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
F1970—12E1
Standard Specification for Special Engineered Fittings, Appurtenances or Valves for Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
M2105.5, Table 2903.9.4
F1973—13E1
Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems
F1974—09(2015)
Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
F1986—01(2011)
Multilayer Pipe Type 2, Compression Joints for Hot and Cold Drinking Water Systems
F2080—15
Specification for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe
F 2090—17
Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms
F2098—08
Standard Specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert and Plastic Insert Fittings
F2159—14
Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F2262—09
Standard Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9
F2389—15
Standard for Pressure-rated Polypropylene (PP) Piping Systems
F2434—14
Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Tubing
F2623—14
Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing
F2735—09
Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
F2769—14
Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold-Water Tubing and Distribution Systems
F2806—10(2015)
Standard Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe (Metric SDR-PR)
F2855—12
Standard Specification for Chlorinated Poly (Vinyl Chloride)/Aluminum/Chlorinated Poly (Vinyl Chloride) (CPVC AL CPVC) Composite Pressure Tubing
F2945—2015
Standard Specification for Polyamide 11 Gas Pressure Pipe, Tubing and Fittings
F2969—12
Standard Specification for Acrylonitrile-butadiene-styrene (ABS) IPS Dimensioned Pressure Pipe
AWC
American Wood Council
222 Catoctin Circle SE, Suite 201
Leesburg VA20175
AWC STJR—2015
Span Tables for Joists and Rafters
ANSI/AWC WFCM—2018
Wood Frame Construction Manual for One- and Two-family Dwellings
ANSI/AWC NDS—2018
National Design Specification (NDS) for Wood Construction—with 2018 Supplement
ANSI/AWC PWF—2015
Permanent Wood Foundation Design Specification
AWPA
American Wood Protection Association
P.O. Box 361784
Birmingham AL35236-1784
C1—03
All Timber Products—Preservative Treatment by Pressure Processes
M4—16
Standard for the Care of Preservative-treated Wood Products
U1—16
USE CATEGORY SYSTEM: User Specification for Treated Wood Except Commodity Specification H
AWS
American Welding Society
8669 NW 36 Street, #130
Miami FL33166
A5.8M/A5.8—2011
Specifications for Filler Metals for Brazing and Braze Welding
ANSI/AWS A5.31M/A5.31—2012
Specification for Fluxes for Brazing and Braze Welding Edition: 2nd
AWWA
American Water Works Association
6666 West Quincy Avenue
Denver CO80235
C104/A21.4—13
Cement-mortar Lining for Ductile-iron Pipe and Fittings
C110/A21.10—12
Ductile-iron and Gray-iron Fittings
C115/A21.15—11
Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
C151/A21.51—09
Ductile-iron Pipe, Centrifugally Cast, for Water
C153/A21.53—11
Ductile-iron Compact Fittings for Water Service
C500—09
Standard for Metal-seated Gate Valves for Water Supply Service
C504—10
Standard for Rubber-seated Butterfly Valves
C507—15
Standard for Ball Valves, 6 In. Through 60 In. (150 mm through 1,500 mm)
C510—07
Double Check Valve Backflow Prevention Assembly
C511—07
Reduced-pressure Principle Backflow Prevention Assembly
C901—16
Polyethylene (PE) Pressure Pipe and Tubing 1/2 in. (13 mm) through 3 in. (76 mm) for Water Service
C903—16
Polyethylene-aluminum-polyethylene (PE-AL-PE) Composite Pressure Pipe, 12 mm (1/2 in.) through 50 mm (2 in.), for Water Service
C904—16
Cross-linked Polyethylene (PEX) Pressure Tubing, 1/2 in. (13 mm) through 3 in. (76 mm) for Water Service
CEN
European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50Brussels
EN 15250-2007
Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods
CISPI
Cast Iron Soil Pipe Institute
2401 Fieldcrest Drive
Mundelein IL60060
301—12
Standard Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
310—12
Standard Specification for Coupling for Use in Connection with Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
CPA
Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg VA20176
ANSI A135.4—2012
Basic Hardboard
ANSI A135.5—2012
Prefinished Hardboard Paneling
ANSI A135.6—2012
Engineered Wood Siding
ANSI A135.7—2012
Engineered Wood Trim
A208.1—2016
Particleboard
CPSC
Consumer Product Safety Commission
4330 East-West Highway
Bethesda MD20814
16 CFR, Part 1201—(2002)
Safety Standard for Architectural Glazing
16 CFR, Part 1209—(2002)
Interim Safety Standard for Cellulose Insulation
16 CFR, Part 1404—(2002)
Cellulose Insulation
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland OH44131-5516
AAMA/WDMA/CSA 101/I.S.2/A440—17
North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights
ANSI/CSA FC I—2014
Fuel Cell Technologies—Part 3-100; Stationary fuel cell power systems-Safety
ASME A112.3.4—2013/CSA B45.9—13
Macerating Toilet Systems and Related Components
ASME A112.4.2—2015/CSA B45.16—15
Water-closet Personal Hygiene Device
ASME A112.18.2—2015/CSA B125.2—2015
A112.18.6—2017/CSA B125.6—2017
Flexible Water Connectors
ASME A112.19.1—2013/CSA B45.2—13
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
ASME A112.19.2—2013/CSA B45.1—13
ASME A112.19.3—2008/CSA B45.4—08 (R2013)
Stainless Steel Plumbing Fixtures
ASSE 1002—2015/ASME A112.1002—2015/CSA B125.12—15
Anti-Siphon Fill Valves
ASSE 1016—2017/ASME 112.1016—2017/CSA B125.16—2017
Performance Requirements for Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations
ASSE 1070—2015/ASME A112.1070—2015/CSA B125.70—15
Performance Requirements for Water-temperature-limiting Devices
A112.19.5—2011/CSA B45.15—2011
Flush Valves and Spuds for Water-closets, Urinals and Tanks
A112.19.7—2017/CSA B45.10—2017
Hydromassage Bathtub Systems
ASME A17.1/CSA B44—2016
Safety Code for Elevators and Escalators
CSA 8—93
Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces
CSA A257.1—2014
Non-reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.2—14
Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.3—14
Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets
B44—2013
Safety Code for Elevators and Escalators
B55.1—2015
Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units
B55.2—2015
Drain Water Heat Recovery Units
B64.1.1—16
Vacuum Breakers, Atmospheric Type (AVB)
B64.1.2—16
Pressure Vacuum Breakers (PVB)
B64.1.3—16
Spill Resistant Pressure Vacuum Breakers (SRPVB)
B64.2—16
Vacuum Breakers, Hose Connection Type (HCVB)
B64.2.1—16
Hose Connection Vacuum Breakers (HCVB) with Manual Draining Feature
B64.2.1.1—16
Hose Connection Dual Check Vacuum Breakers (HCDVB)
B64.2.2—16
Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature
B64.3—16
Dual Check Backflow Preventers with Atmospheric Port (DCAP)
B64.4—16
Backflow Preventers, Reduced Pressure Principle Type (RP)
B64.4.1—16
Reduced Pressure Principle for Fire Sprinklers (RPF)
B64.5—16
Double Check Backflow Preventers (DCVA)
B64.5.1—16
Double Check Valve Backflow Preventers, Type for Fire Systems (DCVAF)
B64.6—16
Dual Check Valve Backflow Preventers (DuC)
B64.7—16
Laboratory Faucet Vacuum Breakers (LFVB)
B137.1—16
Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services
B137.2—16
Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications
B137.3—16
Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
B137.5—16
Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
B137.6—16
Chlorinated polyvinylchloride CPVC Pipe, Tubing and Fittings For Hot- and Cold-water Distribution Systems
B137.9—16
Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems
B137.10—13
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PE-AL-PE) Composite Pressure Pipe Systems
B137.11—16
Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
B137.18—13
Polyethylene of Raised Temperature (PE-RT) Tubing Systems for Pressure Applications
B181.1—15
Acrylonitrile-butadiene-styrene (ABS) Drain, Waste and Vent Pipe and Pipe Fittings
B181.2—15
Polyvinylchloride (PVC) and chlorinated polyvinylchloride (CPVC) Drain, Waste and Vent Pipe and Pipe Fittings
B181.3—15
Polyolefin and polyvinylidene (PVDF) Laboratory Drainage Systems
B182.2—11
PSM Type polyvinylchloride (PVC) Sewer Pipe and Fittings
B182.4—15
Profile polyvinylchloride (PVC) Sewer Pipe & Fittings
B182.6—15
Profile Polyethylene (PE) Sewer Pipe and Fittings for leak-proof Sewer Applications
B182.8—15
Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings
B356—10
Water Pressure Reducing Valves for Domestic Water Supply Systems
B483.1—07(R2012)
Drinking Water Treatment Systems
B602—15
Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe
CSA B45.5—17/IAPMO Z124—17
C22.2 No. 218.1—M89(R2011)
Spas, Hot Tubs and Associated Equipment
C22.2 No. 236—15
Heating and Cooling Equipment
CSA C448 Series—16
Design and Installation of Earth Energy Systems
CSA O325—07
Construction Sheathing
O437-Series—93
Standards on OSB and Waferboard (Reaffirmed 2006)
CAN/CSA/C22.2 No. 60335-2-40—2012
Safety of Household and Similar Electrical Appliances, Part 2-40: Particular Requirements for Electrical Heat Pumps, Air-Conditioners and Dehumidifiers
CSSB
Cedar Shake & Shingle Bureau
P.O. Box 1178
Sumas WA98295-1178
CSSB—97
Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau
DASMA
Door & Access Systems Manufacturers Association International
1300 Sumner Avenue
Cleveland OH44115-2851
105—2016
Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors
108—2017
Standard Method for Testing Garage Doors, Rolling Doors and Flexible Doors; Determination of Structural Performance Under Uniform Static Air Pressure Difference
115—2016
Standard Method for Testing Sectional Garage Doors, Rolling Doors and Flexible Doors: Determination of Structural Performance Under Missile Impact and Cyclic Wind Pressure
DOC
United States Department of Commerce
1401 Constitution Avenue, NW
Washington DC20230
PS 1—09
Structural Plywood
PS 2—10
Performance Standard for Wood-based Structural-use Panels
PS 20—05
American Softwood Lumber Standard
DOTn
U.S. Department of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington DC20590
49 CFR, Parts 192.281(e) & 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards
FEMA
Federal Emergency Management Agency
500 C Street SW
Washington DC20472
FEMA TB-2—08
Flood Damage-resistant Materials Requirements
FEMA TB-11—01
Crawlspace Construction for Buildings Located in Special Flood Hazard Area
FM
FM Approvals
Headquarters Office
1151 Boston-Providence Turnpike
P.O. Box 9102
Norwood MA02062
4450—(1989)
Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992
4880—(2015)
Approval Standard for Class 1 Rating of Building Panels or Interior Finish Materials
GA
Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville MD20782
GA-253—2016
Application of Gypsum Sheathing
HPVA
Hardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston Virginia20190
ANSI/HPVA HP-1—2016
American National Standard for Hardwood and Decorative Plywood
HVI
Home Ventilating Institute
1000 North Rand Road Suite 214
Wauconda Il60084
916—09
Airflow Test Procedure
IAPMO
IAPMO Group
4755 E. Philadelphia Street
Ontario CA91761-USA
CSA B45.5—17/IAPMO Z124—2017
ICC
International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC20001
ANSI/RESNET/ICC 301—2014
Standard for the Calculation and Labeling of the Energy Performance of Low-Rise Residential Buildings using the Energy Rating Index, March 7, 2014, republished 2016
ANSI/RESNET/ICC 380—2016
Standard for Testing Airtightness of Building Enclosures, Airtightness of Heating and Cooling Air Distribution and Airflow of Mechanical Ventilation Systems
ICC/ANSI A117.1—09
Accessible and Usable Buildings and Facilities
ICC 400—17
Standard on the Design and Construction of Log Structures
ICC 500—14
ICC/NSSA Standard on the Design and Construction of Storm Shelters
ICC 600—14
Standard for Residential Construction in High-wind Regions
ICC 901/SRCC 100—2015
IPMC—18
International Property Maintenance Code®
IPSDC—18
International Private Sewage Disposal Code®
IRC—15
International Residential Code®
ISPSC—18
International Swimming Pool and Spa Code®
IEEE
Institute of Electrical and Electronic Engineers, Inc.
3 Park Avenue, 17th Floor
New York NY10016-5997
515.1—2012
IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications
ISO
International Organization for Standardization
Chemin de Blandonnet 8
CP 401
1214 Vernier
Geneva Switzerland
8336—2009
Fibre-cement Flat Sheets-product Specification and Test Methods
15874—2002
Polypropylene Plastic Piping Systems for Hot and Cold Water Installations
MSS
Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, NE
Vienna VA22180
SP-42—2013
Corrosion Resistant Gate, Globe, Angle and Check Valves with Flanged and Butt Weld Ends (Glasses 150, 300 & 600)
SP-58—09
Pipe Hangers and Supports—Materials, Design, Manufacture, Selection, Application and Installation
SP-67—11
Butterfly Valves
SP-70—2011
Gray Iron Gate Valves, Flanged and Threaded Ends
SP-71—2013
Gray Iron Swing Check Valves, Flanged and Threaded Ends
SP-72—2010a
Ball Valves with Flanged or Butt-Welding Ends for General Service
SP-78—2011
Cast Iron Plug Valves, Flanged and Threaded Ends
SP-80—2013
Bronze Gate, Globe, Angle and Check Valves
SP-110—2010a
Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends
SP-122—2012
Plastic Industrial Ball Valves
SP-139—2014
Copper Alloy Gate, Globe, Angle, and Check Valves for Low Pressure/ Low Temperature Plumbing Applications
NAIMA
North American Insulation Manufacturers Association
11 Canal Center Plaza, Suite 101
Alexandria VA22314
AH 116—09
Fibrous Glass Duct Construction Standards, Fifth Edition
M1601.1.1
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy MA02169-7471
13—16
Standard for Installation of Sprinkler Systems
13D—16
Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes
13R—16
Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies
31—16
Standard for the Installation of Oil-burning Equipment
58—17
Liquefied Petroleum Gas Code
70—17
National Electrical Code
72—16
National Fire Alarm and Signaling Code
85—15
Boiler and Combustion Systems Hazards Code
211—16
Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances
259—18
Standard for Test Method for Potential Heat of Building Materials
275—17
Standard Method of Fire Tests for the Evaluation of Thermal Barriers
286—15
Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
501—17
Standard on Manufactured Housing
R202
720—15
Standard for the Installation of Carbon Monoxide (CO) Detectors and Warning Equipment
853—15
Standard on the Installation of Stationary Fuel Cell Power Systems
NFRC
National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD20770
100—2017
Procedure for Determining Fenestration Products U-Factors
200—2017
Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence
400—2017
Procedure for Determining Fenestration Product Air Leakage
NGWA
National Ground Water Association
601 Dempsey Road
Westerville OH43081
ANSI/NGWA 01—14
Water Well Construction Standard
NSF
NSF International
789 N. Dixboro Road
P.O. Box 130140
Ann Arbor MI48105
14—2015
Plastics Piping System Components and Related Materials
41—2011
Nonliquid Saturated Treatment Systems (Composting Toilets)
42—2015
Drinking Water Treatment Units—Anesthetic Effects
44—2015
Residential Cation Exchange Water Softeners
50—2015
Equipment for Swimming Pools, Hot Tubs and Other Recreational Water Facilities
53—2015
Drinking Water Treatment Units—Health Effects
58—2015
Reverse Osmosis Drinking Water Treatment Systems
61—2015
Drinking Water System Components—Health Effects
350—2014
Onsite Residential and Commercial Water Reuse Treatment Systems
358-1—2014
Polyethylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems
358-2—2012
Polypropylene Pipe and Fittings for Water-based Ground Source "Geothermal" Heat Pump Systems
359—2012
Valves for Crosslinked Polyethylene (PEX) Water Distribution Tubing Systems
372—2011
Drinking Water Systems Components—Lead Content
PCA
Portland Cement Association
5420 Old Orchard Road
Skokie IL60077
100—12
Prescriptive Design of Exterior Concrete Walls for One- and Two-family Dwellings (Pub. No. EB241)
SBCA
Structural Building Components Association
6300 Enterprise Lane
Madison WI53719
BCSI—2013 (Updated March 2015)
Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
CFS-BCSI—2008
Cold-formed Steel Building Component Safety Information (CFSBCSI) Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses
FS100—12
Standard Requirements for Wind Pressure Resistance of Foam Plastic Insulating Sheathing Used in Exterior Wall Covering Assemblies
SMACNA
Sheet Metal & Air Conditioning Contractors National Assoc. Inc.
4201 Lafayette Center Drive 
Chantilly VA 20151-1219
SMACNA—10
Fibrous Glass Duct Construction Standards (2003)
SMACNA/ANSI—2005
HVAC Duct Construction Standards—Metal and Flexible 3rd Edition (ANSI)
TMS
The Masonry Society
105 South Sunset Street, Suite Q
Longmont CO80501
402—2016
Building Code Requirements for Masonry Structures
403—2017
Direct Design Handbook for Masonry Structures
404—2016
Standard for the Design of Architectural Cast Stone
602—2016
Specification for Masonry Structures
TPI
Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria VA22314
TPI 1—2014
National Design Standard for Metal-plate-connected Wood Truss Construction
UL
UL LLC
333 Pfingsten Road
Northbrook, IL 60062
17—2008
Vent or Chimney Connector Dampers for Oil-fired Appliances—with revisions through September 2013
55A—04
58—96
Steel Underground Tanks for Flammable and Combustible Liquids—with Revisions through July 1998
80—2007
Steel Tanks for Oil-burner Fuel—with revisions through January 2014
103—2010
Factory-built Chimneys for Residential Type and Building Heating Appliances—with revisions through July 2012
127—2011
Factory-built Fireplaces—with revisions through May 2015
174—04
Household Electric Storage Tank Water Heaters—with revisions through April 2015
180—2012
Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids
181—05
Factory-made Air Ducts and Air Connectors—with revisions through May 2003
181A—2013
Closure Systems for Use with Rigid Air Ducts and Air Connectors—with revisions through December 1998
181B—2013
Closure Systems for Use with Flexible Air Ducts and Air Connectors—with revisions through August 2003
217—06
Single- and Multiple-station Smoke Alarms—with revisions through October 2015
263—2011
Standards for Fire Test of Building Construction and Materials—with revisions through June 2015
268—2009
Smoke Detectors for Fire Alarm Systems
325—02
Door, Drapery, Gate, Louver and Window Operations and Systems—with revisions through May 2015
343—2008
Pumps for Oil-burning Appliances—with revisions through June 2013
378—06
Draft Equipment—with revisions through June 12, 2014
441—10
Gas Vents—with revisions through June 12, 2014
507—99
Standard for Electric Fans
508—99
Industrial Control Equipment—with revisions through October 2013
815—11
Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015
536—97
Flexible Metallic Hose—with revisions through December 2014
641—2010
Type L, Low-temperature Venting Systems—with revisions through June 2013
651—2011
Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—with revisions through May 2014
705—04
Standard for Power Ventilators—with revisions through December 2013
723—08
Standard for Test for Surface Burning Characteristics of Building Materials—with revisions through August 2013
726—95
Oil-fired Boiler Assemblies—with revisions through October 2013
727—06
Oil-fired Central Furnaces—with revisions through October 2013
729—03
Oil-fired Floor Furnaces—with revisions through October 2013
730—03
Oil-fired Wall Furnaces—with revisions through October 2013
732—95
Oil-fired Storage Tank Water Heaters—with revisions through October 2013
737—2011
Fireplaces Stoves—with revisions through August 2015
790—04
Standard Test Methods for Fire Tests of Roof Coverings—with revisions through July 2014
795—2011
Commercial-industrial Gas Heating Equipment—with revisions through November 2013
834—04
Heating, Water Supply and Power Boilers—Electric—with revisions through December 2013
842—07
Valves for Flammable Fluids—with revisions through May 2015
858—05
Household Electric Ranges—with revisions through June 2015
875—09
Electric Dry-bath Heaters—with revisions through December 2013
896—93
Oil-burning Stoves—with revisions through November 2013
923—2013
Microwave Cooking Appliances—with revisions through June 2015
959—2010
Medium Heat Appliance Factory-built Chimneys—with revisions through June 2014
1026—2012
Electric Household Cooking and Food Serving Appliances—with revisions through August 2015
1040—96
Fire Test of Insulated Wall Construction—with revisions through October 2012
1042—2009
Electric Baseboard Heating Equipment—with revisions through September 2014
1256—02
Fire Test of Roof Deck Construction—with revisions through July 2013
1261—01
Electric Water Heaters for Pools and Tubs—with revisions through July 2012
1479—03
Fire Tests of Through-Penetration Firestops—with revisions through June 2015
1482—2011
Solid-Fuel-type Room Heaters—with revisions through August 2015
1563—2009
Standard for Electric Spas, Hot Tubs and Associated Equipment—with revisions through March 2015
1618—09
Wall Protectors, Floor Protectors, and Hearth Extensions—with revisions through October 2015
1693—2010
Electric Radiant Heating Panels and Heating Panel Sets—with revisions through October 2011
1703—02
Flat-plate Photovoltaic Modules and Panels—with revisions through October 2015
1715—97
Fire Test of Interior Finish Material—with revisions through January 2013
1738—2010
Venting Systems for Gas-burning Appliances, Categories II, III and IV—with revisions through November 2014
1741—2010
Inverters, Converters, Controllers and Interconnection System Equipment with Distributed Energy Resources—with revisions through January 2015
1777—07
Chimney Liners—with revisions through October 2015
1897—12
Uplift Tests for Roof Covering Systems—with revisions through September 2015
1995—2011
Heating and Cooling Equipment—with revisions through July 2015
1996—2009
Electric Duct Heaters—with revisions through June 2014
2034—08
Standard for Single- and Multiple-station Carbon Monoxide Alarms—with revisions through March 2015
2075—2013
Standard for Gas and Vapor Detectors and Sensors
2158A—2010
Outline of Investigation for Clothes Dryer Transition Duct
2523—09
Standard for Solid Fuel-fired Hydronic Heating Appliances, Water Heaters and Boilers—with revisions through February 2013
2703—14
Mounting Systems, Mounting Devices, Clamping/Retention Devices and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels
9540—14
Outline of Investigation for Energy Storage Systems and Equipment
UL/CSA/ANCE 60335-2-40—2012
Standard for Household and Similar Electrical Appliances, Part 2: Particular Requirements for Motor-compressors
ULC
ULC
13775 Commerce Parkway
Richmond BCV6V 2V4
CAN/ULC S 102.2—2010
Standard Methods for Test for Surface Burning Characteristics of Building Materials and Assemblies
US-FTC
United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC20580
CFR Title 16(2015)
R-value Rule
WDMA
Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington DC20036-3309
AAMA/WDMA/CSA 101/I.S2/A440—17
North American Fenestration Standard/Specifications for Windows, Doors and Skylights
I.S. 11—13
Industry Standard Analytical Method for Design Pressure (DP) Ratings of Fenestration Products
WMA
World Millwork Alliance (formerly Association of Millwork Distributors Standards AMD)
10047 Robert Trent Parkway
New Port Richey FL34655-4649
ANSI WMA 100—2016
Standard Method of Determining Structural Performance Ratings of Side Hinged Exterior Door Systems and Procedures for Component Substitution
Linked Resources
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Code Compare
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Bookmarks
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Amendment Styling
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More