About this chapter: This code contains numerous references to standards promulgated by other organizations that are used to provide requirements for materials and methods of construction. Chapter 11 contains a comprehensive list of all standards that are referenced in this code. These standards, in essence, are part of this code to the extent of the reference to the standard.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7.
AHRI
Air Conditioning, Heating & Refrigeration Institute
2111 Wilson Boulevard, Suite 500
Arlington VA22201
400 (I-P)—2015
Performance Rating of Liquid to Liquid Heat Exchangers
1160 (I-P)—2014
Performance Rating of Heat Pump Pool Heaters
ANSI
American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY10036
A108/A118/A136.1—2008
Specifications for Installation of Ceramic Tile
Z21.56a/CSA 4.7—2017
Gas Fired Pool Heaters
APSP
The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria VA22314
ANSI/APSP/ICC 4—12
American National Standard for Aboveground/Onground Residential Swimming Pools—Includes Addenda A Approved April 4, 2013
ANSI/APSP/ICC 7—13
American National Standard for Suction Entrapment Avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Catch Basins
ANSI/APSP/ICC 14—2014
American National Standard for Portable Electric Spa Energy Efficiency
ANSI/APSP/ICC 15a—2011
American National Standard for Energy Efficiency Residential Inground Swimming Pool and Spas—Includes Addenda A Approved January 9, 2013
ANSI/APSP/ICC 16—11
American National Standard for Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs
ASCE/SEI
American Society of Civil Engineers Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA20191-4400
ASCE 24—14
Flood Resistant Design & Construction
ASME
American Society of Mechanical Engineers
Two Park Avenue
New York NY10016-5990
A112.1.2—2012
Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-connected Receptors)
B16.15—2013
Cast Alloy Threaded Fittings: Classes 125 and 250
ASTM
ASTM International
100 Barr Harbor, P.O. Box C700
West Conshohocken PA19428-2959
A182—15
Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-temperature Service
A240/A240M—15a
Standard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
A312/A312M—15a
Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes
A403—15
Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings
B88—14
Standard Specification for Seamless Copper Water Tube
B447—12a
Specification for Welded Copper Tube
D1527—99(2005)
Specifications for Acrylonitrile Butadiene Styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1593—13
Standard Specification for Nonrigid Vinyl Chloride Plastic Film and Sheeting
D1785—15
Specification for Poly Vinyl Chloride (PVC) Plastic Pipe, Schedules 40, 80 and 120
D2241—15
Standard Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR Series)
D2464—15
Standard Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2466—15
Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
D2467—15
Standard Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2672—14
Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement
D2846/D2846M—14
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-Water Distribution Systems
F437—15
Standard Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F438—15
Standard Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40
F439—13
Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80
F1346—91(2010)
Standard Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs
CPSC
Consumer Product Safety Commission
4330 East-West Highway
Bethesda MD20814
16 CFR Part 1207—04
Safety Standard for Swimming Pool Slides
CSA
CSA Group
8501 East Pleasant Valley Road
Cleveland OH44131-5516
B137.2—16
Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Application
B137.3—16
Rigid Polyvinylchloride (PVC) Pipe and Fitting and Pressure Applications
B137.6—16
Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing, and Fitting for Hot- and Cold-water Distribution Systems
C22.2 No. 108—14
Liquid Pumps
C22.2 No. 218.1—13
Spas, Hot Tubs and Associated Equipment
C22.2 No. 236—15
Heating and Cooling Equipment
Z21.56a/CSA 4.7—2017
Gas Fired Pool Heaters
IAPMO
IAPMO
4755 E. Philadelphia Street
Ontario CA91761-USA
IAPMO Z124.7—2013
Prefabricated Plastic Spa Shells
ICC
International Code Council, Inc.
500 New Jersey Avenue, NW 6th Floor
Washington DC20001
ICC 900/SRCC 300—2015
Solar Thermal System Standard
ICC 901/SRCC 100—2015
Solar Thermal Collector Standard
NEMA
National Electrical Manufacturers Association
1300 North 17th Street Suite 900
Rosslyn VA22209
NEMA Z535—2017
ANSI/NEMA Color Chart
409.3
NFPA
National Fire Protection Association
1 Batterymarch Park
Quincy MA02169-7471
NFPA 70—2017
National Electrical Code
NSF
NSF International
789 N. Dixboro Road P.O. Box 130140
Ann Arbor MI48105
NSF 14—2015
Plastics Pumping Systems Components and Related Materials
NSF 50—2015
Equipment for Swimming Pools, Spas, Hot Tubs, and Other Recreational Water Facilities
UL
UL LLC
333 Pfingsten Road
Northbrook IL60062
372—2007
Automatic Electrical Controls for Household and Similar Use—Part 2: Particular Requirements for Burner Ignition Systems and Components—with revisions through July 2012
873—2007
Temperature-indicating and Regulating Equipment—with revisions through February 2015
1004-1—12
Standard for Rotating Electrical Machines General Requirements—with revisions through June 2011
1081—2008
Standard for Swimming Pool Pumps, Filters and Chlorinators—with revisions through March 2014
1261—2001
Standard for Electric Water Heaters for Pools and Tubs—with revisions through July 2012
1563—2009
Standard for Electric Hot Tubs, Spas and Associated Equipment—with revisions through March 2015
1995—2011
Heating and Cooling Equipment—with revisions through July 2015
2017—2008
General-purpose Signaling Devices and Systems—with revisions through May 2011