This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7.
<#class="whitespace_nowrap">AASHTO | American Association of State Highway and Transportation Officials 444 North Capitol Street, Northwest, #249 Washington, DC 20001 |
|
Standard reference number |
Title | Referenced in code section number |
HB-17—2002 | Specification for Highway Bridges, 17th Edition 2002 | 503.2.6 |
AFSI | Architectural Fabric Structures Institute c/o Industrial Fabric Association International 1801 County Road B West Roseville, MN 55113 |
|
Standard reference number |
Title | Referenced in code section number |
ASI—77 | Design and Standard Manual | 2403.10.2 |
API | American Petroleum Institute 1220 L Street, Northwest Washington, DC 20005 |
|
Standard reference number |
Title | Referenced in code section number |
Spec 12P—(1995) | Specification for Fiberglass Reinforced Plastic Tanks | 3404.2.13.1.5 (Reaffirmed 2000) |
RP 651—(1997) | Cathodic Protection of Aboveground Petroleum Storage Tanks | 3406.7, 3406.7.1 |
Std 653—(2001) | Tank Inspection, Repair, Alteration and Reconstruction | 3406.7 |
RP 752—(2003) | Management of Hazards Associated with Location of Process Plant Buildings, CMA Managers Guide | 3406.7 |
RP 1604—(1996) | Closure of Underground Petroleum Storage Tanks | 3404.2.13 |
RP 1615—(1996) | Installation of Underground-petroleum Storage Systems | 3404.2.13.1.5, 3406.7 |
Std 2000—(1998) | Venting Atmosphere and Low-pressure Storage Tanks: Nonrefrigerated and Refrigerated | 3404.2.7.3.6 |
RP 2001—(2005) | Fire Protection in Refineries, 8th Edition | 3406.7 |
RP 2003—(1998) | Protection Against Ignitions Arising out of Static, Lightning and Stray Currents | 3406.7 |
Publ 2009—(2002) | Safe Welding and Cutting Practices in Refineries, Gas Plants and Petrochemical Plants | 3406.7 |
Std 2015—(2001) | Safe Entry and Clearing of Petroleum Storage Tanks | 3406.7, 3406.7.2 |
RP 2023—(2001) | Guide for Safe Storage and Handling of Heated Petroleum-derived Asphalt Products and Crude-oil Residue | 3406.7, 3406.7.3 |
Publ 2028—(2002) | Flame Arrestors in Piping Systems | 3404.2.7.3.2 |
Publ 2201—(2003) | Procedures for Welding or Hot Tapping on Equipment in Service | 3406.7 |
RP 2350—(2005) | Overfill Protection for Storage Tanks in Petroleum Facilities, 3rd Edition | 3404.2.7.5.8, 3406.4.6, 3406.7 |
ASME | The American Society of Mechanical Engineers Three Park Avenue New York, NY 10016-5990 |
|
Standard reference number |
Title | Referenced in code section number |
A13.1—96 (Reaffirmed 2002) | Scheme for the Identification of Piping Systems | 2609.3, 2703.2.2.1, 3003.4.3, 3203.4.5, 3403.5.2 |
A17.1/CSA B44—2007 | Safety Code for Elevators and Escalators | 508.1.5, 607.1, 907.4.3, 1007.4 |
A17.3—2005 | Safety Code for Existing Elevators and Escalators | 4603.2 |
A18.1—2005 | Safety Standard for Platform Lifts and Stairway Chair Lifts | 604.2.6 |
B16.18—2001 | Cast Copper Alloy Solder Joint Pressure Fittings | 909.13.1 (Reaffirmed 2005) |
B16.22—2001 | Wrought Copper and Copper Alloy Solder-joint Pressure Fittings | 909.13.1 (Reaffirmed 2005) |
B31.1—2004 | Power Piping | Table 3403.6.2 |
B31.3—2004 | Process Piping | 2209.5.4.3.1, 2703.2.2.2, Table 3403.6.2 |
B31.4—2006 | Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids | Table 3403.6.2 |
B31.9—2004 | Building Services Piping | Table 3403.6.2, 3403.6.3, 3403.6.11 |
BPVC—2004 | ASME Boiler and Pressure Vessel Code, 2001 Edition of (Sections I, II, IV, V & VI, VIII) | 2209.5.4.2, 2703.2.1, 3003.2, 3003.3.2, 3203.4.3, 3203.7, 3404.2.13.1.5, 3506.3.1, 3506.4.1, 3506.4.8 |
ASTM | ASTM International 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 |
|
Standard reference number |
Title | Referenced in code section number |
B 42—02e01 | Specification for Seamless Copper Pipe, Standard Sizes | 909.13.1 |
B 43—98(2004) | Specification for Seamless Red Brass Pipe, Standard Sizes | 909.13.1 |
B 68—02 | Specification for Seamless Copper Tube, Bright Annealed | 909.13.1 |
B 88—03 | Specification for Seamless Copper Water Tube | 909.13.1 |
B 251—02e01 | Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube | 909.13.1 |
B 280—03 | Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service | 909.13.1 |
D 56—05 | Test Method for Flash Point by Tag Closed Tester | 3402.1 |
D 86—07a | Test Method for Distillation of Petroleum Products at Atmospheric Pressure | 2702.1 |
D 92—05a | Test Method for Flash and Fire Points by Cleveland Open Cup | 1501.2, 3401.2, 3402.1 |
D 93—07 | Test Method for Flash Point by Pensky-Martens Closed Up Tester | 3402.1 |
D 323—06 | Test Method for Vapor Pressure of Petroleum Products (Reid Method) | 2702.1 |
D 3278—(2004)e01 | Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus | 3402.1 |
E 84—07 | Test Method for Surface Burning Characteristics of Building Materials | 802.1, 803.1, 803.1.1, 803.1.2, 803.5.1, 803.6.2, 803.9, 804.1, 804.1.1, 804.2.4 |
E 681—04 | Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases) | 3502.1 |
E 1354—04a | Standard Test Method for Heat and Visible Smoke Release Rates forMaterials and Products Using an Oxygen Consumption Calorimeter | 304.3.2, 304.3.4, 317.1, 808.1 |
E 1529—06 | Test Method for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies | 3404.2.9.2.3 |
E 1537—07 | Test Method for Fire Testing of Upholstered Furniture | 805.1.1.2, 805.2.1.2, 805.3.1.2, 805.4.1.2 |
E 1590—07 | Test Method for Fire Testing of Mattresses | 805.1.2.2, 805.2.2.2, 805.3.2.2, 805.4.2.2 |
E 1966—01 | Test Method for Fire-resistant Joint Systems | 702.1 |
E 2072—04 | Standard Specification for Pholuminescent (Phosphorescent) Safety Markings | 1024.4 |
E 2404—07a | Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics | 803.6.2 |
E 2573—07 | Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics | 803.9 |
F 2200—05 | Standard Specification for Automated Vehicular Gate Construction | 503.5, 503.6, D103.5 |
BHMA | Builders Hardware Manufacturers' Association 355 Lexington Avenue, 17th Floor New York, NY 10017-6603 |
|
Standard reference number |
Title | Referenced in code section number |
A156.10—05 | American National Standard for Power-operated Pedestrian Doors | 1008.1.4.2 |
A156.19—02 | American National Standard for Power Assist and Low-energy Power-operated Doors | 1008.1.4.2 |
CA | State of California Department of Consumer Affairs Bureau of Home Furnishings and Thermal Insulation 3485 Orange Grove Avenue North Highlands, CA 95660-5595 |
|
Standard reference number |
Title | Referenced in code section number |
California Technical Bulletin 129—1992 | Flammability Test Procedure for Mattresses for Use in Public Buildings | 805.1.1.2, 805.2.2.2, 805.3.2.2, 805.4.2.2 |
California Technical Bulletin 133—1991 | Flammability Test Procedure for Seating Furniture for Use in Public Occupancies | 805.1.1.2, 805.2.1.2, 805.4.1.2 |
CGA | Compressed Gas Association 4221 Walney Road, 16th Floor Arlington, VA 20151-2923 |
|
Standard reference number |
Title | Referenced in code section number |
C-7—(2004) | Guide to the Preparation of Precautionary Labeling and Marking of Compressed Gas Containers | 3003.4.2, 3203.4.2 |
G-13—(2006) | Storage and Handling of Silane and Silane Mixtures (an American National Standard) | 4104.1, 4104.2, 4105.3 |
P-1—(2000) | Safe Handling of Compressed Gases in Containers | 3005.7 |
ANSI/P-18—(2006) | Standard for Bulk Inert Gas Systems at Consumer Sites (an American National Standard) | 3201.1 |
P-20—(2003) | Standard for Classification of Toxic Mixtures | E103.1.3.1 |
P-23—(2003) | Standard for Categorizing Gas Mixtures Containing Flammable and Nonflammable Components | E102.1.2 |
S-1.1—(2005) | Relief Device Standards—Part 1—Cylinders for Compressed Gases | 2209.5.4.2, 3003.3.2, 3203.2 |
S-1.2—(2005) | Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases | 2209.5.4.2, 3003.3.2, 3203.2 |
S-1.3—(2005) | Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases | 2209.5.4.2, 2209.5.4.3.5, 3003.3.2, 3203.2 |
V-1—(2005) | Standard for Gas Cylinder Valve Outlet and Inlet Connections | 2605.2.1 |
CGR | Coast Guard Regulations c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 |
|
Standard reference number |
Title | Referenced in code section number |
46 CFR Parts 30, 32, 35 & 39—1999 | Shipping | 3406.8 |
CPSC | Consumer Product Safety Commission 4330 East West Highway Bethesda, MD 20814 |
|
Standard reference number |
Title | Referenced in code section number |
16 CFR Part 1500.41—1984 | Method for Testing Primary Irritant Substances | 202 |
16 CFR Part 1500.42—1984 | Test for Eye Irritants | 202 |
16 CFR Part 1500.44—2001 | Method for Testing Extremely Flammable and Flammable Solids | 3602.1 |
16 CFR Part 1500—1984 | Hazardous Substances and Articles; Administration and Enforcement Regulations | 3301.1.3, 3302.1 |
16 CFR Part 1507—2001 | Fireworks Devices | 3301.1.3, 3302.1 |
DOC | U.S. Department of Commerce 1401 Constitution Avenue, NW Washington, DC 20230 |
|
Standard reference number |
Title | Referenced in code section number |
16 CFR Part 1632—1999 | Standard for the Flammability of Mattress and Mattress Pads (FF 4—72, Amended) | 805.1.2.1, 805.2.2.1, 805.3.2.1, 805.4.2.1 |
DOL | U.S. Department of Labor c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 |
|
Standard reference number |
Title | Referenced in code section number |
29 CFR Part 1910.1000—1974 | Air Contaminants | 1204.2.1, 2702.1 |
29 CFR Part 1910.1200—1999 | Hazard Communication | 2702.1, 3303.6 |
DOTn | U.S. Department of Transportation Office of Hazardous Material Safety 1200 New Jersey Avenue, SE East Building, 2nd Floor Washington, DC 20590 |
|
Standard reference number |
Title | Referenced in code section number |
33 CFR Part 154 —1998 | Facilities Transferring Oil or Hazardous Material in Bulk | 3406.8 |
33 CFR Part 155 —1998 | Oil or Hazardous Material Pollution Prevention Regulations for Vessels | 3406.8 |
33 CFR Part 156 —1998 | Oil and Hazardous Material Transfer Operations | 3406.8 |
49 CFR Parts 100-185—2005 | Hazardous Materials Regulations | 2605.4, 3003.2, 3203.4.3, 3203.7, 3301.1, 3301.1.3, 3301.3, 3302.1, 3406.5.1.15 |
49 CFR Part 172—2005 | Hazardous Materials Tables, Special Provisions, Hazardous Materials Communications, Emergency Response Information and Training Requirements | 3304.6.5.2 |
49 CFR Part 173—2005 | Shippers—General Requirements for Shipments and Packagings | 3306.3 |
49 CFR Part 173.137—2005 | Shippers—General Requirements for Shipments and Packagings: Class 8—Assignment of Packing Group | 3102.1 |
DOTy | U.S. Department of Treasury c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 |
|
Standard reference number |
Title | Referenced in code section number |
27 CFR Part 55—1998 | Commerce in Explosives, as amended through April 1, 1998 | 3302.1, 3304.6.5.2 |
EN | European Committee for Standardization (EN) Central Secretariat Rue de Stassart 36 B-10 50 Brussels |
|
Standard reference number |
Title | Referenced in code section number |
European Standard EN 1081 | 1998 Resilient Floor Coverings—Determination of the Electrical Resistance | 2209.5.1.1 |
EPA | Environmental Protection Agency Ariel Rios Building 1200 Pennsylvania Avenue, NW Washington, DC 20460 |
|
Standard reference number |
Title | Referenced in code section number |
40 CFR Part 355—2008 | Emergency Planning and Notification | H101.4 |
FCC | Federal Communications Commission Wireless Telecommunications Bureau (WTB) 445 12th Street, SW Washington, DC 20554 |
|
Standard reference number |
Title | Referenced in code section number |
47 CFR Part 90.219—2007 | Private Land Mobile Radio Services—Use of Signal Boosters | J103.2.5 |
ICC | International Code Council, Inc. 500 New Jersey Avenue, NW, 6th Floor Washington, DC 20001 |
|
Standard reference number |
Title | Referenced in code section number |
ICC/ANSI A117.1—03 | Accessible and Usable Buildings and Facilities | 907.6.2.3.4, 1010.1, 1010.6.5, 1010.9, 1011.3, 1022.8 |
ICC 300—07 | Standard on Bleachers, Folding and Telescopic Seating and Grandstands | 1028.1.1 |
IBC—09 | International Building Code® | 102.3, 102.4, 102.5, 201.3, 202, 304.1.3, 306.1, 311.1.1, 311.3, 313.1, 408.7.2, 504.1, 508.1, 508.1.2, 603.2, 603.5.2, 603.6.1, 603.8, 604.1, 604.2.9, 604.2.14.1, 604.2.14.1.3, 604.2.15, 604.2.15.1.1, 604.2.16, 607.3, 608.4, 608.8, 701.1, 704.1, 801.1, 803.1, Table 803.3, 803.7.1, 803.7.2, 807.1.2, 807.4.2.2, 901.4.1, 901.4.2, 903.2, 903.2.3.2, 903.2.9.1, 903.3.2, 903.3.5.2, 903.6, 907.1.1, 907.2.6.2, 907.2.6.3.3, 907.2.7, 907.2.13, 907.2.18, 907.2.21, 907.7.5, 909.1, 909.2, 909.3, 909.4.3, 909.5, 909.5.2, 909.5.2.1, 909.10.5, 909.11, 911.2, 914.1, 914.2.1, 914.3.1, 914.5.3, Table 914.8.2, 914.10, 1003.2, 1003.5, 1006.3, 1007.2, 1007.4, 1007.5, 1007.6.2, 1007.8, 1007.9, 1008.1.4.1, 1008.1.4.3, 1008.1.7, 1008.1.9.1, 1008.1.10.1, 1009.4.2, 1009.12, 1009.13.1, 1010.1, 1010.6.3, 1010.6.4, 1010.6.5, 1010.9, 1011.4, 1011.5.3, 1012.1, 1013.1.1, 1014.2.7, Table 1016.1, 1017.2, 1018.1, Table 1018.1, 1021.1, Table 1021.2, 1022.1, 1022.2.1, 1022.3, 1022.4, 1022.8, 1022.9.1, 1023.3, 1023.5, 1025.2, 1025.3, 1027.3, 1028.1.1, 1028.6.2, 1028.14.2, 1104.6, 1106.17, 1107.1, 1107.4, 1203.3, 1207.1, 1414.1, 1502.1, 1504.2, 1504.3.1, 1504.3.2.6, 1504.3.3, 1505.2, 1801.1, 1801.4, 1803.2.2, 1803.3.1, 1803.3.2, 1803.3.3, 1803.3.4, 1803.3.8, 1803.14, 1803.14.1, 1803.15.1, 1804.3.1, 1805.2.3.2, 1805.3.1, 1805.3.2, 1805.3.3, 1903.1, 2005.1, 2009.2, 2009.4, 2009.6, 2201.1, 2201.4, 2203.1, 2207.4, 2208.3, 2208.3.1, Table 2209.3.1, 2209.3.2.3, 2209.3.2.6.1, 2209.3.3, 2210.1, 2211.1, 2211.3.1, 2211.4.1, 2211.8.1.2.3, 2301.3, Table 2306.2, 2306.3.1, 2306.3.2.1, 2306.3.2.2, 2306.8, 2307.2, 2308.2, 2402.1, 2403.8.2, 2403.8.4, 2404.1, 2503.1, 2703.2.2.2, 2703.2.8, 2703.8.1, Table 2703.8.2, 2703.8.3.1, 2703.8.4.1, 2703.9.9, 2704.13, 2705.2, 2705.3.9, 2801.1, 2904.3, 2904.4, 2904.5, 3003.16.1, 3003.16.2, 3006.2, 3203.1.2, 3203.5.2, 3204.2, 3204.2.2.2, 3204.4.3, 3205.4.1, 3304.2, Table 3304.5.2.3, 3305.5, 3401.3, 3404.2.7.7, 3404.2.8.1, 3404.2.8.2, 3404.2.9.3, 3404.2.9.4, 3404.3.3.5, 3404.3.7.1, 3404.3.8, 3405.3.4, 3405.3.5.3, 3405.3.7.1, 3405.3.7.2, 3405.3.7.3, 3405.3.7.4, 3405.3.7.5.1, 3406.2.3, 3406.4.1, 3504.2.1.1, 3606.2.2, 3606.2.3, 3606.4.2, 3703.1.4.2, 3705.3.1, 3809.11.2, 3904.1.2, 4004.1.2, 4104.1.4, 4106.1.1, 4304.1, 4601.2, 4601.3, 4604.5, 4604.17, 4604.17.1, Table 4604.17.2, B104.2, Table B105.1, H102.1 |
IFGC—09 | International Fuel Gas Code® | 201.3, 603.1, 603.1.2, 603.3.2.4, 603.5.2, 603.8, 1403.1, 1403.3, 1604.5, 2101.1, 2103.1, 2104.1, 2104.2, 2201.1, 2201.6, 2209.3.2.3, 2209.3.2.6, 2404.15.1, 2404.15.2, 2404.16.1, Table 2703.1.1(1), 3001.1, 3501.1, 3503.1.4, 3803.1, 3803.2.1.7, 3803.3 |
IMC—09 | International Mechanical Code® | 201.3, 202, 308.3, 603.1, 603.1.2, 603.2, 603.3, 603.5.2, 603.8, 606.1, 606.2, 606.3, 606.4, 606.7, 606.8, 606.16, 608.6.1, 609.1, 903.2.11.4, 904.11, 907.4.1, 909.1, 909.10.2, 1015.5, 1018.5.1, 1204.2.1, 1205.3, 1403.1, 1504.7, 1504.7.2, 1604.5, 1803.2.2, 1803.10.4, 1803.14, 1903.2, 1903.3, 2101.1, 2103.1, 2104.2, 2201.1, 2201.6, 2209.3.2.3, 2211.3.1, 2211.4.3, 2211.7.1, 2404.15.1, 2404.15.2, Table 2703.1.1(1), 2703.8.4.2, 2703.8.5.2, 2703.8.6.2, 2704.3.1, 2903.5, 3003.7.6, 3003.16.9, 3005.5, 3006.2.2, 3204.2.1.3, 3204.2.2.3, 3205.4.1.1, 3401.3, 3403.6.1, 3404.2.8.9, 3405.3.7.5.1, 3406.2, 3406.4.4, 3506.4.3, 3703.1.3, 3703.2.3.2, 3704.2.2.7, 3705.3.1, 3705.3.2, 3803.2.1.7 |
IPC—09 | International Plumbing Code® | 201.3, 903.3.5, 912.5, 2211.2.3, 2704.2.2.6 |
IPMC—09 | International Property Maintenance Code® | 311.1.1 |
IRC—09 | International Residential Code® | 202, 1001.1 |
IWUIC—09 | International Wildland-Urban Interface Code™ | 103.3, 304.1.2, B103.3 |
ISO | International Organization for Standardization (ISO) ISO Central Secretariat 1 ch, de la Voie-Creuse, Case postale 56 CH-1211 Geneva 20, Switzerland |
|
Standard reference number |
Title | Referenced in code section number |
ISO 8115—86 | Cotton Bales—Dimensions and Density | Table 1804.2.2.1, Table 2703.1(1) |
NEMA |
National Electrical Manufacturer's Association |
|
Standard reference number |
Title | Referenced in code section number |
250—2003 | Enclosures for Electrical Equipment (1,000 Volt Maximum) | 3705.2 |
NFPA | National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 |
|
Standard reference number |
Title | Referenced in code section number |
10—07 | Portable Fire Extinguishers | Table 901.6.1, 906.2, 906.3, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4, 2106.3, I101.1 |
11—05 | Low-, Medium- and High-expansion Foam | 904.7, 3404.2.9.2.2 |
12—05 | Carbon Dioxide Extinguishing Systems | Table 901.6.1, 904.8, 904.11 |
12A—04 | Halon 1301 Fire Extinguishing Systems | Table 901.6.1, 904.9 |
13—07 | Installation of Sprinkler Systems | Table 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2, 904.11, 905.3.4, 907.7.3, 2301.1, 2304.2, Table 2306.2, 2306.9, 2307.2, 2307.2.1, 2308.2.2, 2308.2.2.1, 2308.4, 2310.1, 2501.1, 2804.1, 2806.5.7, 3404.3.3.9, Table 3404.3.6.3(7), 3404.3.7.5.1, 3404.3.8.4 |
13D—07 | Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes | 903.3.1.3, 903.3.5.1.1 |
13R—07 | Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height | 903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4 |
14—07 | Installation of Standpipe and Hose Systems | 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8 |
15—07 | Water Spray Fixed Systems for Fire Protection | 3404.2.9.2.3 |
16—07 | Installation of Foam-water Sprinkler and Foam-water Spray Systems | 904.7, 904.11 |
17—02 | Dry Chemical Extinguishing Systems | Table 901.6.1, 904.6, 904.11 |
17A—02 | Wet Chemical Extinguishing Systems | Table 901.6.1, 904.5, 904.11 |
20—07 | Installation of Stationary Pumps for Fire Protection | 913.1, 913.2, 913.5.1 |
22—03 | Water Tanks for Private Fire Protection | 507.2.2 |
24—07 | Installation of Private Fire Service Mains and Their Appurtenances | 507.2.1, 1909.5 |
25—08 | Inspection, Testing and Maintenance of Water-based Fire Protection Systems | 507.5.3, Table 901.6.1, 904.7.1, 912.6, 913.5, I101.1 |
30—08 | Flammable and Combustible Liquids Code | 3403.6.2, 3403.6.2.1, 3404.2.7, 3404.2.7.1, 3404.2.7.2, 3404.2.7.3.6, 3404.2.7.4, 3404.2.7.6, 3404.2.7.7, 3404.2.7.8, 3404.2.7.9, 3404.2.9.3, 3404.2.9.4, 3404.2.9.6.1.1, 3404.2.9.6.1.2, 3404.2.9.6.1.3, 3404.2.9.6.1.4, 3404.2.9.6.1.5, 3404.2.9.6.2, 3404.2.9.7.4, 3404.2.10.2, 3404.2.11.4, 3404.2.11.5.2, 3404.2.12.1, 3404.3.1, 3404.3.6, Table 3404.3.6.3(1), Table 3404.3.6.3(2), Table 3404.3.6.3(3), 3404.3.7.2.3, 3404.3.8.4, 3406.8.3 |
30A—08 | Code for Motor Fuel-dispensing Facilities and Repair Garages | 2201.4, 2201.5, 2201.6, 2206.6.3, 2210.1 |
30B—07 | Manufacture and Storage of Aerosol Products | 2801.1, 2803.1, 2804.1, Table 2804.3.1, Table 2804.3.2, Table 2804.3.2.2, 2804.4.1, 2804.5.2, 2804.6, 2806.2.3, 2806.3.2, Table 2806.4, 2806.5.1, 2806.5.6, 2807.1 |
31—06 | Installation of Oil-burning Equipment | 603.1.7, 603.3.1, 603.3.3 |
32—07 | Dry Cleaning Plants | 1207.1, 1207.3 |
33—07 | Spray Application Using Flammable or Combustible Materials | 1504.3.2 |
34—07 | Dipping and Coating Processes Using Flammable or Combustible Liquids | 1505.3, 1505.4.1.1 |
35—05 | Manufacture of Organic Coatings | 2001.3, 2005.4 |
40—07 | Storage and Handling of Cellulose Nitrate Film | 306.2 |
51—07 | Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes | 2601.5, 2607.1, 2609.1 |
51A—06 | Acetylene Cylinder Charging Plants | 2608.1 |
52—06 | Vehicular Fuel System Code | 3001.1 |
55—05 | Standard for the Storage, Use and Handling of Compressed Gases and Cryogenic Fluids in Portable and Stationery Containers Cylinders and Tanks | 2209.2.1, 3201.1, 3501.1, 4001.1 |
58—08 | Liquefied Petroleum Gas Code | 603.4.2.1.1, 3801.1, 3803.1, 3803.2.1, 3803.2.1.2, 3803.2.1.7, 3803.2.2, 3804.1, 3804.3.1, 3804.4, 3806.2, 3806.3, 3807.2, 3808.1, 3808.2, 3809.11.2, 3811.3 |
59A—06 | Production, Storage and Handling of Liquefied Natural Gas (LNG) | 3001.1, 3201.1 |
61—08 | Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities | Table 1304.1 |
69—08 | Explosion Prevention Systems | 911.1, 911.3, Table 1304.1 |
70—08 | National Electrical Codc | 603.1.3, 603.1.7, 603.5.2, 604.2.15.1, 605.3, 605.4, 605.9, 606.16, 904.3.1, 907.1, 909.11, 909.12.1, 909.16.3, 1106.3.4, 1204.2.3, Table 1304.1, 1404.7, 1503.2.1, 1503.2.1.1, 1503.2.1.4, 1503.2.5, 1504.9.4, 1604.5, 1703.2, 1803.7.1, 1803.7.2, 1803.7.3, 1903.4, 2004.1, 2205.4, 2208.8.1.2.4, 2209.2.3, 2211.3.1, 2211.8.1.2.4, 2403.12.6.1, 2404.15.7, 2606.4, 2703.7.3, 3003.7.6, 3003.8, 3003.16.11, 3003.16.14, 3203.6, 3203.7.2, 3403.1, Table 3403.1.1, 3403.1.3, 3404.2.8.12, 3404.2.8.17, 3406.2.8, 3503.1.5, 3503.1.5.1, 3507.1.10, 3606.5.5, 3606.5.6, 3704.2.2.8 |
72—07 | National Fire Alarm Code | 508.1.5, Table 901.6.1, 903.4.1, 904.3.5, 907.2, 907.2.6, 907.2.11, 907.2.13.2, 907.3, 907.4.3, 907.4.4, 907.6.2.1.2, 907.6.2.2, 907.7, 907.7.1, 907.7.2, 907.7.5, 907.8, 907.8.1, 907.8.2, 907.9, 907.9.2, 907.9.5, I101.1, J103.1.4 |
80—07 | Fire Doors and Other Opening Protectives | 703.1.3, 1008.1.3.3 |
85—07 | Boiler and Combustion System Hazards Code | Table 1304.1 |
86—07 | Ovens and Furnaces | 2101.1 |
92B—05 | Smoke Management Systems in Malls, Atria and Large Spaces | 909.8 |
99—05 | Health Care Facilities | 3006.4 |
101—06 | Life Safety Code | 1028.6.2 |
105—07 | Installation of Smoke Door Assemblies and Other Opening Protectives | 703.1.2 |
110—05 | Emergency and Standby Power Systems | 604.1, 604.3, 604.4, 913.5.2, 913.5.3 |
111—05 | Stored Electrical Energy Emergency and Standby Power Systems | . 604.1, 604.3, 604.4 |
120—04 | Coal Preparation Plants | Table 1304.1 |
160—06 | Flame Effects Before an Audience | 308.3.2 |
170—06 | Standard for Fire Safety and Emergency Symbols | 1024.2.6.1 |
211—06 | Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances | 603.2 |
241—04 | Safeguarding Construction, Alteration and Demolition Operations | 1401.1 |
253—06 | Standard Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source | 804.3 |
260—03 | Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture | 805.1.1.1, 805.2.1.1, 805.3.1.1, 805.4.1.1 |
261—03 | Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes | 805.2.1.1, 805.3.1.1, 805.4.1.1 |
265—07 | Method of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings in Full Height Panels and Walls | 803.5.1, 803.5.1.1, 803.5.1.2, 805.4.1.1 |
286—06 | Standard Method of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth | 803.1, 803.1.2, 803.1.2.1, 803.5.1 |
303—06 | Fire Protection Standard for Marinas and Boatyards | 905.3.7, 4503.5, 4503.6, 4504.2 |
385—07 | Tank Vehicles for Flammable and Combustible Liquids | 3406.5.4.5, 3406.6, 3406.6.1 |
407—07 | Aircraft Fuel Servicing | 1106.2, 1106.3 |
409—04 | Aircraft Hangars | 914.8.2, Table 914.8.2, 914.8.2.1, 914.8.5 |
430—04 | Storage of Liquid and Solid Oxidizers | 4004.1.4 |
484—06 | Combustible Metals | Table 1304.1 |
490—02 | Storage of Ammonium Nitrate | 3301.1.5 |
495—06 | Explosive Materials Code | 911.1, 911.4, 3301.1.1, 3301.1.5, 3302.1, 3304.2, 3304.6.2, 3304.6.3, 3304.7.1, 3305.1, 3306.1, 3306.5.2.1, 3306.5.2.3, 3307.1, 3307.9, 3307.11, 3307.15 |
498—06 | Safe Havens and Interchange Lots for Vehicles Transporting Explosives | 3301.1.2 |
505—06 | Powered Industrial Trucks, Including Type Designations, Areas of Use, Maintenance and Operation | 2703.7.3 |
654—06 | Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids | Table 1304.1 |
655—07 | Prevention of Sulfur Fires and Explosions | Table 1304.1 |
664—07 | Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities | Table 1304.1, 1905.3 |
701—04 | Methods of Fire Tests for Flame-propagation of Textiles and Films | 806.2, 807.1, 807.1.2, 807.2, 807.4.2.2, 1703.5, 2404.2 |
703—06 | Fire Retardant Impregnated Wood and Fire Retardant Coatings for Building Materials | 803.4 |
704—07 | Identification of the Hazards of Materials for Emergency Response | 606.7, 1802.1, 2404.2, 2703.2.2.1, 2703.2.2.2, 2703.5, 2703.10.2, 2705.1.10, 2705.2.1.1, 2705.4.4, 3203.4.1, 3404.2.3.2, F101.1, F101.2 |
750—06 | Water Mist Fire Protection Systems | Table 901.6.1 |
1122—08 | Model Rocketry | 3301.1.4 |
1123—06 | Fireworks Display | 3302.1, 3304.2, 3308.1, 3308.2.2, 3308.5, 3308.6 |
1124—06 | Manufacture, Transportation, Storage and Retail Sales of Fireworks and Pyrotechnic Articles | 3302.1, 3304.2, 3305.1, 3305.3, 3305.4, 3305.5 |
1125—07 | Manufacture of Model Rocket and High Power Rocket Motors | 3301.1.4 |
1126—06 | Use of Pyrotechnics Before a Proximate Audience | 3304.2, 3305.1, 3308.1, 3308.2.2, 3308.4, 3308.5 |
1127—08 | High Power Rocketry | 3301.1.4 |
1142—07 | Water Supply for Suburban and Rural Fire Fighting | B103.3 |
2001—08 | Clean Agent Fire Extinguishing Systems | Table 901.6.1, 904.10 |
UL | Underwriters Laboratories, Inc. 333 Pfingsten Road Northbrook, IL 60062 |
|
Standard reference number |
Title | Referenced in code section number |
30—95 | Metal Safety Cans—with Revisions through December 2004 | 2703.9.10, 2705.1.10, 3405.2.4 |
58—96 | Steel Underground Tanks for Flammable and Combustible Liquids— with Revisions through July 1998 | 3404.2.13.1.5 |
199E—04 | Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers | 904.11.4.1 |
217—06 | Single and Multiple Station Smoke Alarms—with Revisions through May 2007 | 907.2.11 |
268—06 | Smoke Detectors for Fire Alarm Signaling Systems | 907.2.6.2 |
300—05 | Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Equipment | 904.11 |
325—02 | Door, Drapery, Gate, Louver and Window Operators and Systems— with Revisions through February 2006 | 503.5, 503.6, D103.5 |
710B—04 | Recirculating Systems—with Revisions through April 2006 | 904.11 |
723—03 | Standard for Test for Surface Burning Characteristics of Building Materials— with Revisions through May 2005 | 802.1, 803.5.1, 803.6.2, 803.9, 804.1, 804.2.4 |
793—03 | Automatically Operated Roof Vents for Smoke and Heat—with Revisions through April 2004 | 910.3.1 |
864—03 | Control Units and Accessories for Fire Alarm Systems—with Revisions through March 2006 | 909.12 |
900—04 | Air Filter Units | 1504.7.8 |
924—06 | Standard for Safety Emergency Lighting and Power Equipment | 1011.4, 2403.12.6.1 |
1275—05 | Flammable Liquid Storage Cabinets—with Revisions through May 2006 | 2703.8.7.1, 3404.3.2.1.1 |
1313—93 | Standard for Nonmetallic Safety Cans for Petroleum Products—with Revisions through May 2003 | 2703.9.10 |
1315—95 | Standard for Safety for Metal Waste Paper Containers—with Revisions through December 2003 | 808.1 |
1316—94 | Glass Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols, and Alcohol-gasoline Mixtures—with Revisions through May 2006 | 3404.2.13.1.5 |
1363—07 | Relocatable Power Taps | 605.4.1 |
1975—06 | Fire Tests for Foamed Plastics Used for Decorative Purpose | 807.4.2.1, 808.2 |
1994—04 | Standard for Luminous Egress Path Marking Systems—with Revisions through February 2005 | 1024.2.1, 1024.2.3,1024.2.4, 1024.4 |
2075—07 | Standard for Gas and Vapor Detectors and Sensors | 2211.7.2.1 |
2079—04 | Tests for Fire Resistance of Building Joint Systems—with Revisions through May 2006 | 702.1 |
2085—97 | Protected Aboveground Tanks for Flammable and Combustible Liquids— with Revisions through December 1999 | 202, 3402.1, 3404.2.9.2.3, 3404.2.9.7.5, 3405.3.8.2 |
2200—04 | Stationary Engine Generator Assemblies—with Revisions through July 2004 | 604.1.1 |
2208—05 | Solvent Distillation Units—with Revisions through December 2006 | 3405.4.1 |
2245—06 | Below-grade Vaults for Flammable Liquid Storage Tanks | 3404.2.8.1 |
2335—01 | Fire Tests of Storage Pallets—with Revisions through September 2004 | 2308.2.1 |
USC | United States Code c/o Superintendent of Documents U.S. Government Printing Office Washington, DC 20402-9325 |
|
Standard reference number |
Title | Referenced in code section number |
18 USC Part 1, Chapter 40 | Importation, Manufacture, Distribution and Storage of Explosive Materials | 3302.1 |
21 USC Chapter 9 | United States Food, Drug and Cosmetic Act | 4002.1 |