This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.7.
AASHTO American Association of State Highway and Transportation Officials
444 North Capitol Street, Northwest,
#249 Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
HB-17—2002 Specification for Highway Bridges, 17th Edition 2002 503.2.6
     
AFSI Architectural Fabric Structures Institute c/o Industrial Fabric Association International
1801 County Road B
West Roseville, MN 55113
 
Standard
reference
number
Title Referenced
in code
section number
ASI—77 Design and Standard Manual 2403.10.2
     
API American Petroleum Institute
1220 L Street,
Northwest Washington, DC 20005
 
Standard
reference
number
Title Referenced
in code
section number
Spec 12P—(1995) Specification for Fiberglass Reinforced Plastic Tanks 3404.2.13.1.5 (Reaffirmed 2000)
RP 651—(1997) Cathodic Protection of Aboveground Petroleum Storage Tanks 3406.7, 3406.7.1
Std 653—(2001) Tank Inspection, Repair, Alteration and Reconstruction 3406.7
RP 752—(2003) Management of Hazards Associated with Location of Process Plant Buildings, CMA Managers Guide 3406.7
RP 1604—(1996) Closure of Underground Petroleum Storage Tanks 3404.2.13
RP 1615—(1996) Installation of Underground-petroleum Storage Systems 3404.2.13.1.5, 3406.7
Std 2000—(1998) Venting Atmosphere and Low-pressure Storage Tanks: Nonrefrigerated and Refrigerated 3404.2.7.3.6
RP 2001—(2005) Fire Protection in Refineries, 8th Edition 3406.7
RP 2003—(1998) Protection Against Ignitions Arising out of Static, Lightning and Stray Currents 3406.7
Publ 2009—(2002) Safe Welding and Cutting Practices in Refineries, Gas Plants and Petrochemical Plants 3406.7
Std 2015—(2001) Safe Entry and Clearing of Petroleum Storage Tanks 3406.7, 3406.7.2
RP 2023—(2001) Guide for Safe Storage and Handling of Heated Petroleum-derived Asphalt Products and Crude-oil Residue 3406.7, 3406.7.3
Publ 2028—(2002) Flame Arrestors in Piping Systems 3404.2.7.3.2
Publ 2201—(2003) Procedures for Welding or Hot Tapping on Equipment in Service 3406.7
RP 2350—(2005) Overfill Protection for Storage Tanks in Petroleum Facilities, 3rd Edition 3404.2.7.5.8, 3406.4.6, 3406.7
     
ASME The American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
A13.1—96 (Reaffirmed 2002) Scheme for the Identification of Piping Systems 2609.3, 2703.2.2.1, 3003.4.3, 3203.4.5, 3403.5.2
A17.1/CSA B44—2007 Safety Code for Elevators and Escalators 508.1.5, 607.1, 907.4.3, 1007.4
A17.3—2005 Safety Code for Existing Elevators and Escalators 4603.2
A18.1—2005 Safety Standard for Platform Lifts and Stairway Chair Lifts 604.2.6
B16.18—2001 Cast Copper Alloy Solder Joint Pressure Fittings 909.13.1 (Reaffirmed 2005)
B16.22—2001 Wrought Copper and Copper Alloy Solder-joint Pressure Fittings 909.13.1 (Reaffirmed 2005)
B31.1—2004 Power Piping Table 3403.6.2
B31.3—2004 Process Piping 2209.5.4.3.1, 2703.2.2.2, Table 3403.6.2
B31.4—2006 Pipeline Transportation Systems for Liquid Hydrocarbons and Other Liquids Table 3403.6.2
B31.9—2004 Building Services Piping Table 3403.6.2, 3403.6.3, 3403.6.11
BPVC—2004 ASME Boiler and Pressure Vessel Code, 2001 Edition of (Sections I, II, IV, V & VI, VIII) 2209.5.4.2, 2703.2.1, 3003.2, 3003.3.2, 3203.4.3, 3203.7, 3404.2.13.1.5, 3506.3.1, 3506.4.1, 3506.4.8
     
ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
 
Standard
reference
number
Title Referenced
in code
section number
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes 909.13.1
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes 909.13.1
B 68—02 Specification for Seamless Copper Tube, Bright Annealed 909.13.1
B 88—03 Specification for Seamless Copper Water Tube 909.13.1
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 909.13.1
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 909.13.1
D 56—05 Test Method for Flash Point by Tag Closed Tester 3402.1
D 86—07a Test Method for Distillation of Petroleum Products at Atmospheric Pressure 2702.1
D 92—05a Test Method for Flash and Fire Points by Cleveland Open Cup 1501.2, 3401.2, 3402.1
D 93—07 Test Method for Flash Point by Pensky-Martens Closed Up Tester 3402.1
D 323—06 Test Method for Vapor Pressure of Petroleum Products (Reid Method) 2702.1
D 3278—(2004)e01 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 3402.1
E 84—07 Test Method for Surface Burning Characteristics of Building Materials 802.1, 803.1, 803.1.1, 803.1.2, 803.5.1, 803.6.2, 803.9, 804.1, 804.1.1, 804.2.4
E 681—04 Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases) 3502.1
E 1354—04a Standard Test Method for Heat and Visible Smoke Release Rates forMaterials and Products Using an Oxygen Consumption Calorimeter 304.3.2, 304.3.4, 317.1, 808.1
E 1529—06 Test Method for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies 3404.2.9.2.3
E 1537—07 Test Method for Fire Testing of Upholstered Furniture 805.1.1.2, 805.2.1.2, 805.3.1.2, 805.4.1.2
E 1590—07 Test Method for Fire Testing of Mattresses 805.1.2.2, 805.2.2.2, 805.3.2.2, 805.4.2.2
E 1966—01 Test Method for Fire-resistant Joint Systems 702.1
E 2072—04 Standard Specification for Pholuminescent (Phosphorescent) Safety Markings 1024.4
E 2404—07a Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Vinyl Wall or Ceiling Coverings to Assess Surface Burning Characteristics 803.6.2
E 2573—07 Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics 803.9
F 2200—05 Standard Specification for Automated Vehicular Gate Construction 503.5, 503.6, D103.5
     
BHMA Builders Hardware Manufacturers' Association
355 Lexington Avenue, 17th Floor
New York, NY 10017-6603
 
Standard
reference
number
Title Referenced
in code
section number
A156.10—05 American National Standard for Power-operated Pedestrian Doors 1008.1.4.2
A156.19—02 American National Standard for Power Assist and Low-energy Power-operated Doors 1008.1.4.2
     
CA State of California Department of Consumer Affairs Bureau of Home Furnishings and Thermal Insulation
3485 Orange Grove Avenue
North Highlands, CA 95660-5595
 
Standard
reference
number
Title Referenced
in code
section number
California Technical Bulletin 129—1992 Flammability Test Procedure for Mattresses for Use in Public Buildings 805.1.1.2, 805.2.2.2, 805.3.2.2, 805.4.2.2
California Technical Bulletin 133—1991 Flammability Test Procedure for Seating Furniture for Use in Public Occupancies 805.1.1.2, 805.2.1.2, 805.4.1.2
     
CGA Compressed Gas Association
4221 Walney Road, 16th Floor
Arlington, VA 20151-2923
 
Standard
reference
number
Title Referenced
in code
section number
C-7—(2004) Guide to the Preparation of Precautionary Labeling and Marking of Compressed Gas Containers 3003.4.2, 3203.4.2
G-13—(2006) Storage and Handling of Silane and Silane Mixtures (an American National Standard) 4104.1, 4104.2, 4105.3
P-1—(2000) Safe Handling of Compressed Gases in Containers 3005.7
ANSI/P-18—(2006) Standard for Bulk Inert Gas Systems at Consumer Sites (an American National Standard) 3201.1
P-20—(2003) Standard for Classification of Toxic Mixtures E103.1.3.1
P-23—(2003) Standard for Categorizing Gas Mixtures Containing Flammable and Nonflammable Components E102.1.2
S-1.1—(2005) Relief Device Standards—Part 1—Cylinders for Compressed Gases 2209.5.4.2, 3003.3.2, 3203.2
S-1.2—(2005) Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases 2209.5.4.2, 3003.3.2, 3203.2
S-1.3—(2005) Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases 2209.5.4.2, 2209.5.4.3.5, 3003.3.2, 3203.2
V-1—(2005) Standard for Gas Cylinder Valve Outlet and Inlet Connections 2605.2.1
     
CGR Coast Guard Regulations c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
46 CFR Parts 30, 32, 35 & 39—1999 Shipping 3406.8
     
CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814
 
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1500.41—1984 Method for Testing Primary Irritant Substances 202
16 CFR Part 1500.42—1984 Test for Eye Irritants 202
16 CFR Part 1500.44—2001 Method for Testing Extremely Flammable and Flammable Solids 3602.1
16 CFR Part 1500—1984 Hazardous Substances and Articles; Administration and Enforcement Regulations 3301.1.3, 3302.1
16 CFR Part 1507—2001 Fireworks Devices 3301.1.3, 3302.1
     
DOC U.S. Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
 
Standard
reference
number
Title Referenced
in code
section number
16 CFR Part 1632—1999 Standard for the Flammability of Mattress and Mattress Pads (FF 4—72, Amended) 805.1.2.1, 805.2.2.1, 805.3.2.1, 805.4.2.1
     
DOL U.S. Department of Labor c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000—1974 Air Contaminants 1204.2.1, 2702.1
29 CFR Part 1910.1200—1999 Hazard Communication 2702.1, 3303.6
     
DOTn U.S. Department of Transportation Office of Hazardous Material Safety
1200 New Jersey Avenue, SE East Building, 2nd Floor
Washington, DC 20590
 
Standard
reference
number
Title Referenced
in code
section number
33 CFR Part 154 —1998 Facilities Transferring Oil or Hazardous Material in Bulk 3406.8
33 CFR Part 155 —1998 Oil or Hazardous Material Pollution Prevention Regulations for Vessels 3406.8
33 CFR Part 156 —1998 Oil and Hazardous Material Transfer Operations 3406.8
49 CFR Parts 100-185—2005 Hazardous Materials Regulations 2605.4, 3003.2, 3203.4.3, 3203.7, 3301.1, 3301.1.3, 3301.3, 3302.1, 3406.5.1.15
49 CFR Part 172—2005 Hazardous Materials Tables, Special Provisions, Hazardous Materials Communications, Emergency Response Information and Training Requirements 3304.6.5.2
49 CFR Part 173—2005 Shippers—General Requirements for Shipments and Packagings 3306.3
49 CFR Part 173.137—2005 Shippers—General Requirements for Shipments and Packagings: Class 8—Assignment of Packing Group 3102.1
     
DOTy U.S. Department of Treasury c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
27 CFR Part 55—1998 Commerce in Explosives, as amended through April 1, 1998 3302.1, 3304.6.5.2
     
EN European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
 
Standard
reference
number
Title Referenced
in code
section number
European Standard EN 1081 1998 Resilient Floor Coverings—Determination of the Electrical Resistance 2209.5.1.1
     
EPA Environmental Protection Agency
Ariel Rios Building 1200 Pennsylvania Avenue, NW
Washington, DC 20460
 
Standard
reference
number
Title Referenced
in code
section number
40 CFR Part 355—2008 Emergency Planning and Notification H101.4
     
FCC Federal Communications Commission Wireless Telecommunications Bureau (WTB)
445 12th Street, SW
Washington, DC 20554
 
Standard
reference
number
Title Referenced
in code
section number
47 CFR Part 90.219—2007 Private Land Mobile Radio Services—Use of Signal Boosters J103.2.5
     
ICC International Code Council, Inc.
500 New Jersey Avenue, NW, 6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
ICC/ANSI A117.1—03 Accessible and Usable Buildings and Facilities 907.6.2.3.4, 1010.1, 1010.6.5, 1010.9, 1011.3, 1022.8
ICC 300—07 Standard on Bleachers, Folding and Telescopic Seating and Grandstands 1028.1.1
IBC—09 International Building Code® 102.3, 102.4, 102.5, 201.3, 202, 304.1.3, 306.1, 311.1.1, 311.3, 313.1, 408.7.2, 504.1, 508.1, 508.1.2, 603.2, 603.5.2, 603.6.1, 603.8, 604.1, 604.2.9, 604.2.14.1, 604.2.14.1.3, 604.2.15, 604.2.15.1.1, 604.2.16, 607.3, 608.4, 608.8, 701.1, 704.1, 801.1, 803.1, Table 803.3, 803.7.1, 803.7.2, 807.1.2, 807.4.2.2, 901.4.1, 901.4.2, 903.2, 903.2.3.2, 903.2.9.1, 903.3.2, 903.3.5.2, 903.6, 907.1.1, 907.2.6.2, 907.2.6.3.3, 907.2.7, 907.2.13, 907.2.18, 907.2.21, 907.7.5, 909.1, 909.2, 909.3, 909.4.3, 909.5, 909.5.2, 909.5.2.1, 909.10.5, 909.11, 911.2, 914.1, 914.2.1, 914.3.1, 914.5.3, Table 914.8.2, 914.10, 1003.2, 1003.5, 1006.3, 1007.2, 1007.4, 1007.5, 1007.6.2, 1007.8, 1007.9, 1008.1.4.1, 1008.1.4.3, 1008.1.7, 1008.1.9.1, 1008.1.10.1, 1009.4.2, 1009.12, 1009.13.1, 1010.1, 1010.6.3, 1010.6.4, 1010.6.5, 1010.9, 1011.4, 1011.5.3, 1012.1, 1013.1.1, 1014.2.7, Table 1016.1, 1017.2, 1018.1, Table 1018.1, 1021.1, Table 1021.2, 1022.1, 1022.2.1, 1022.3, 1022.4, 1022.8, 1022.9.1, 1023.3, 1023.5, 1025.2, 1025.3, 1027.3, 1028.1.1, 1028.6.2, 1028.14.2, 1104.6, 1106.17, 1107.1, 1107.4, 1203.3, 1207.1, 1414.1, 1502.1, 1504.2, 1504.3.1, 1504.3.2.6, 1504.3.3, 1505.2, 1801.1, 1801.4, 1803.2.2, 1803.3.1, 1803.3.2, 1803.3.3, 1803.3.4, 1803.3.8, 1803.14, 1803.14.1, 1803.15.1, 1804.3.1, 1805.2.3.2, 1805.3.1, 1805.3.2, 1805.3.3, 1903.1, 2005.1, 2009.2, 2009.4, 2009.6, 2201.1, 2201.4, 2203.1, 2207.4, 2208.3, 2208.3.1, Table 2209.3.1, 2209.3.2.3, 2209.3.2.6.1, 2209.3.3, 2210.1, 2211.1, 2211.3.1, 2211.4.1, 2211.8.1.2.3, 2301.3, Table 2306.2, 2306.3.1, 2306.3.2.1, 2306.3.2.2, 2306.8, 2307.2, 2308.2, 2402.1, 2403.8.2, 2403.8.4, 2404.1, 2503.1, 2703.2.2.2, 2703.2.8, 2703.8.1, Table 2703.8.2, 2703.8.3.1, 2703.8.4.1, 2703.9.9, 2704.13, 2705.2, 2705.3.9, 2801.1, 2904.3, 2904.4, 2904.5, 3003.16.1, 3003.16.2, 3006.2, 3203.1.2, 3203.5.2, 3204.2, 3204.2.2.2, 3204.4.3, 3205.4.1, 3304.2, Table 3304.5.2.3, 3305.5, 3401.3, 3404.2.7.7, 3404.2.8.1, 3404.2.8.2, 3404.2.9.3, 3404.2.9.4, 3404.3.3.5, 3404.3.7.1, 3404.3.8, 3405.3.4, 3405.3.5.3, 3405.3.7.1, 3405.3.7.2, 3405.3.7.3, 3405.3.7.4, 3405.3.7.5.1, 3406.2.3, 3406.4.1, 3504.2.1.1, 3606.2.2, 3606.2.3, 3606.4.2, 3703.1.4.2, 3705.3.1, 3809.11.2, 3904.1.2, 4004.1.2, 4104.1.4, 4106.1.1, 4304.1, 4601.2, 4601.3, 4604.5, 4604.17, 4604.17.1, Table 4604.17.2, B104.2, Table B105.1, H102.1
IFGC—09 International Fuel Gas Code® 201.3, 603.1, 603.1.2, 603.3.2.4, 603.5.2, 603.8, 1403.1, 1403.3, 1604.5, 2101.1, 2103.1, 2104.1, 2104.2, 2201.1, 2201.6, 2209.3.2.3, 2209.3.2.6, 2404.15.1, 2404.15.2, 2404.16.1, Table 2703.1.1(1), 3001.1, 3501.1, 3503.1.4, 3803.1, 3803.2.1.7, 3803.3
IMC—09 International Mechanical Code® 201.3, 202, 308.3, 603.1, 603.1.2, 603.2, 603.3, 603.5.2, 603.8, 606.1, 606.2, 606.3, 606.4, 606.7, 606.8, 606.16, 608.6.1, 609.1, 903.2.11.4, 904.11, 907.4.1, 909.1, 909.10.2, 1015.5, 1018.5.1, 1204.2.1, 1205.3, 1403.1, 1504.7, 1504.7.2, 1604.5, 1803.2.2, 1803.10.4, 1803.14, 1903.2, 1903.3, 2101.1, 2103.1, 2104.2, 2201.1, 2201.6, 2209.3.2.3, 2211.3.1, 2211.4.3, 2211.7.1, 2404.15.1, 2404.15.2, Table 2703.1.1(1), 2703.8.4.2, 2703.8.5.2, 2703.8.6.2, 2704.3.1, 2903.5, 3003.7.6, 3003.16.9, 3005.5, 3006.2.2, 3204.2.1.3, 3204.2.2.3, 3205.4.1.1, 3401.3, 3403.6.1, 3404.2.8.9, 3405.3.7.5.1, 3406.2, 3406.4.4, 3506.4.3, 3703.1.3, 3703.2.3.2, 3704.2.2.7, 3705.3.1, 3705.3.2, 3803.2.1.7
IPC—09 International Plumbing Code® 201.3, 903.3.5, 912.5, 2211.2.3, 2704.2.2.6
IPMC—09 International Property Maintenance Code® 311.1.1
IRC—09 International Residential Code® 202, 1001.1
IWUIC—09 International Wildland-Urban Interface Code™ 103.3, 304.1.2, B103.3
     
ISO International Organization for Standardization (ISO)
ISO Central Secretariat 1 ch, de la Voie-Creuse, Case postale 56 CH-1211
Geneva 20, Switzerland
 
Standard
reference
number
Title Referenced
in code
section number
ISO 8115—86 Cotton Bales—Dimensions and Density Table 1804.2.2.1, Table 2703.1(1)
     
NEMA
National Electrical Manufacturer's Association
1300 N. 17th Street, Suite 1752
Rosslyn, VA 22209
 
Standard
reference
number
Title Referenced
in code
section number
250—2003 Enclosures for Electrical Equipment (1,000 Volt Maximum) 3705.2
     
NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
 
Standard
reference
number
Title Referenced
in code
section number
10—07 Portable Fire Extinguishers Table 901.6.1, 906.2, 906.3, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4, 2106.3, I101.1
11—05 Low-, Medium- and High-expansion Foam 904.7, 3404.2.9.2.2
12—05 Carbon Dioxide Extinguishing Systems Table 901.6.1, 904.8, 904.11
12A—04 Halon 1301 Fire Extinguishing Systems Table 901.6.1, 904.9
13—07 Installation of Sprinkler Systems Table 903.3.1.1, 903.3.2, 903.3.5.1.1, 903.3.5.2, 904.11, 905.3.4, 907.7.3, 2301.1, 2304.2, Table 2306.2, 2306.9, 2307.2, 2307.2.1, 2308.2.2, 2308.2.2.1, 2308.4, 2310.1, 2501.1, 2804.1, 2806.5.7, 3404.3.3.9, Table 3404.3.6.3(7), 3404.3.7.5.1, 3404.3.8.4
13D—07 Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes 903.3.1.3, 903.3.5.1.1
13R—07 Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height 903.3.1.2, 903.3.5.1.1, 903.3.5.1.2, 903.4
14—07 Installation of Standpipe and Hose Systems 905.2, 905.3.4, 905.4.2, 905.6.2, 905.8
15—07 Water Spray Fixed Systems for Fire Protection 3404.2.9.2.3
16—07 Installation of Foam-water Sprinkler and Foam-water Spray Systems 904.7, 904.11
17—02 Dry Chemical Extinguishing Systems Table 901.6.1, 904.6, 904.11
17A—02 Wet Chemical Extinguishing Systems Table 901.6.1, 904.5, 904.11
20—07 Installation of Stationary Pumps for Fire Protection 913.1, 913.2, 913.5.1
22—03 Water Tanks for Private Fire Protection 507.2.2
24—07 Installation of Private Fire Service Mains and Their Appurtenances 507.2.1, 1909.5
25—08 Inspection, Testing and Maintenance of Water-based Fire Protection Systems 507.5.3, Table 901.6.1, 904.7.1, 912.6, 913.5, I101.1
30—08 Flammable and Combustible Liquids Code 3403.6.2, 3403.6.2.1, 3404.2.7, 3404.2.7.1, 3404.2.7.2, 3404.2.7.3.6, 3404.2.7.4, 3404.2.7.6, 3404.2.7.7, 3404.2.7.8, 3404.2.7.9, 3404.2.9.3, 3404.2.9.4, 3404.2.9.6.1.1, 3404.2.9.6.1.2, 3404.2.9.6.1.3, 3404.2.9.6.1.4, 3404.2.9.6.1.5, 3404.2.9.6.2, 3404.2.9.7.4, 3404.2.10.2, 3404.2.11.4, 3404.2.11.5.2, 3404.2.12.1, 3404.3.1, 3404.3.6, Table 3404.3.6.3(1), Table 3404.3.6.3(2), Table 3404.3.6.3(3), 3404.3.7.2.3, 3404.3.8.4, 3406.8.3
30A—08 Code for Motor Fuel-dispensing Facilities and Repair Garages 2201.4, 2201.5, 2201.6, 2206.6.3, 2210.1
30B—07 Manufacture and Storage of Aerosol Products 2801.1, 2803.1, 2804.1, Table 2804.3.1, Table 2804.3.2, Table 2804.3.2.2, 2804.4.1, 2804.5.2, 2804.6, 2806.2.3, 2806.3.2, Table 2806.4, 2806.5.1, 2806.5.6, 2807.1
31—06 Installation of Oil-burning Equipment 603.1.7, 603.3.1, 603.3.3
32—07 Dry Cleaning Plants 1207.1, 1207.3
33—07 Spray Application Using Flammable or Combustible Materials 1504.3.2
34—07 Dipping and Coating Processes Using Flammable or Combustible Liquids 1505.3, 1505.4.1.1
35—05 Manufacture of Organic Coatings 2001.3, 2005.4
40—07 Storage and Handling of Cellulose Nitrate Film 306.2
51—07 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes 2601.5, 2607.1, 2609.1
51A—06 Acetylene Cylinder Charging Plants 2608.1
52—06 Vehicular Fuel System Code 3001.1
55—05 Standard for the Storage, Use and Handling of Compressed Gases and Cryogenic Fluids in Portable and Stationery Containers Cylinders and Tanks 2209.2.1, 3201.1, 3501.1, 4001.1
58—08 Liquefied Petroleum Gas Code 603.4.2.1.1, 3801.1, 3803.1, 3803.2.1, 3803.2.1.2, 3803.2.1.7, 3803.2.2, 3804.1, 3804.3.1, 3804.4, 3806.2, 3806.3, 3807.2, 3808.1, 3808.2, 3809.11.2, 3811.3
59A—06 Production, Storage and Handling of Liquefied Natural Gas (LNG) 3001.1, 3201.1
61—08 Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities Table 1304.1
69—08 Explosion Prevention Systems 911.1, 911.3, Table 1304.1
70—08 National Electrical Code 603.1.3, 603.1.7, 603.5.2, 604.2.15.1, 605.3, 605.4, 605.9, 606.16, 904.3.1, 907.1, 909.11, 909.12.1, 909.16.3, 1106.3.4, 1204.2.3, Table 1304.1, 1404.7, 1503.2.1, 1503.2.1.1, 1503.2.1.4, 1503.2.5, 1504.9.4, 1604.5, 1703.2, 1803.7.1, 1803.7.2, 1803.7.3, 1903.4, 2004.1, 2205.4, 2208.8.1.2.4, 2209.2.3, 2211.3.1, 2211.8.1.2.4, 2403.12.6.1, 2404.15.7, 2606.4, 2703.7.3, 3003.7.6, 3003.8, 3003.16.11, 3003.16.14, 3203.6, 3203.7.2, 3403.1, Table 3403.1.1, 3403.1.3, 3404.2.8.12, 3404.2.8.17, 3406.2.8, 3503.1.5, 3503.1.5.1, 3507.1.10, 3606.5.5, 3606.5.6, 3704.2.2.8
72—07 National Fire Alarm Code 508.1.5, Table 901.6.1, 903.4.1, 904.3.5, 907.2, 907.2.6, 907.2.11, 907.2.13.2, 907.3, 907.4.3, 907.4.4, 907.6.2.1.2, 907.6.2.2, 907.7, 907.7.1, 907.7.2, 907.7.5, 907.8, 907.8.1, 907.8.2, 907.9, 907.9.2, 907.9.5, I101.1, J103.1.4
80—07 Fire Doors and Other Opening Protectives 703.1.3, 1008.1.3.3
85—07 Boiler and Combustion System Hazards Code Table 1304.1
86—07 Ovens and Furnaces 2101.1
92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 909.8
99—05 Health Care Facilities 3006.4
101—06 Life Safety Code 1028.6.2
105—07 Installation of Smoke Door Assemblies and Other Opening Protectives 703.1.2
110—05 Emergency and Standby Power Systems 604.1, 604.3, 604.4, 913.5.2, 913.5.3
111—05 Stored Electrical Energy Emergency and Standby Power Systems . 604.1, 604.3, 604.4
120—04 Coal Preparation Plants Table 1304.1
160—06 Flame Effects Before an Audience 308.3.2
170—06 Standard for Fire Safety and Emergency Symbols 1024.2.6.1
211—06 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 603.2
241—04 Safeguarding Construction, Alteration and Demolition Operations 1401.1
253—06 Standard Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source 804.3
260—03 Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture 805.1.1.1, 805.2.1.1, 805.3.1.1, 805.4.1.1
261—03 Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes 805.2.1.1, 805.3.1.1, 805.4.1.1
265—07 Method of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings in Full Height Panels and Walls 803.5.1, 803.5.1.1, 803.5.1.2, 805.4.1.1
286—06 Standard Method of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth 803.1, 803.1.2, 803.1.2.1, 803.5.1
303—06 Fire Protection Standard for Marinas and Boatyards 905.3.7, 4503.5, 4503.6, 4504.2
385—07 Tank Vehicles for Flammable and Combustible Liquids 3406.5.4.5, 3406.6, 3406.6.1
407—07 Aircraft Fuel Servicing 1106.2, 1106.3
409—04 Aircraft Hangars 914.8.2, Table 914.8.2, 914.8.2.1, 914.8.5
430—04 Storage of Liquid and Solid Oxidizers 4004.1.4
484—06 Combustible Metals Table 1304.1
490—02 Storage of Ammonium Nitrate 3301.1.5
495—06 Explosive Materials Code 911.1, 911.4, 3301.1.1, 3301.1.5, 3302.1, 3304.2, 3304.6.2, 3304.6.3, 3304.7.1, 3305.1, 3306.1, 3306.5.2.1, 3306.5.2.3, 3307.1, 3307.9, 3307.11, 3307.15
498—06 Safe Havens and Interchange Lots for Vehicles Transporting Explosives 3301.1.2
505—06 Powered Industrial Trucks, Including Type Designations, Areas of Use, Maintenance and Operation 2703.7.3
654—06 Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids Table 1304.1
655—07 Prevention of Sulfur Fires and Explosions Table 1304.1
664—07 Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities Table 1304.1, 1905.3
701—04 Methods of Fire Tests for Flame-propagation of Textiles and Films 806.2, 807.1, 807.1.2, 807.2, 807.4.2.2, 1703.5, 2404.2
703—06 Fire Retardant Impregnated Wood and Fire Retardant Coatings for Building Materials 803.4
704—07 Identification of the Hazards of Materials for Emergency Response 606.7, 1802.1, 2404.2, 2703.2.2.1, 2703.2.2.2, 2703.5, 2703.10.2, 2705.1.10, 2705.2.1.1, 2705.4.4, 3203.4.1, 3404.2.3.2, F101.1, F101.2
750—06 Water Mist Fire Protection Systems Table 901.6.1
1122—08 Model Rocketry 3301.1.4
1123—06 Fireworks Display 3302.1, 3304.2, 3308.1, 3308.2.2, 3308.5, 3308.6
1124—06 Manufacture, Transportation, Storage and Retail Sales of Fireworks and Pyrotechnic Articles 3302.1, 3304.2, 3305.1, 3305.3, 3305.4, 3305.5
1125—07 Manufacture of Model Rocket and High Power Rocket Motors 3301.1.4
1126—06 Use of Pyrotechnics Before a Proximate Audience 3304.2, 3305.1, 3308.1, 3308.2.2, 3308.4, 3308.5
1127—08 High Power Rocketry 3301.1.4
1142—07 Water Supply for Suburban and Rural Fire Fighting B103.3
2001—08 Clean Agent Fire Extinguishing Systems Table 901.6.1, 904.10
     
UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
 
Standard
reference
number
Title Referenced
in code
section number
30—95 Metal Safety Cans—with Revisions through December 2004 2703.9.10, 2705.1.10, 3405.2.4
58—96 Steel Underground Tanks for Flammable and Combustible Liquids— with Revisions through July 1998 3404.2.13.1.5
199E—04 Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers 904.11.4.1
217—06 Single and Multiple Station Smoke Alarms—with Revisions through May 2007 907.2.11
268—06 Smoke Detectors for Fire Alarm Signaling Systems 907.2.6.2
300—05 Fire Testing of Fire Extinguishing Systems for Protection of Restaurant Cooking Equipment 904.11
325—02 Door, Drapery, Gate, Louver and Window Operators and Systems— with Revisions through February 2006 503.5, 503.6, D103.5
710B—04 Recirculating Systems—with Revisions through April 2006 904.11
723—03 Standard for Test for Surface Burning Characteristics of Building Materials— with Revisions through May 2005 802.1, 803.5.1, 803.6.2, 803.9, 804.1, 804.2.4
793—03 Automatically Operated Roof Vents for Smoke and Heat—with Revisions through April 2004 910.3.1
864—03 Control Units and Accessories for Fire Alarm Systems—with Revisions through March 2006 909.12
900—04 Air Filter Units 1504.7.8
924—06 Standard for Safety Emergency Lighting and Power Equipment 1011.4, 2403.12.6.1
1275—05 Flammable Liquid Storage Cabinets—with Revisions through May 2006 2703.8.7.1, 3404.3.2.1.1
1313—93 Standard for Nonmetallic Safety Cans for Petroleum Products—with Revisions through May 2003 2703.9.10
1315—95 Standard for Safety for Metal Waste Paper Containers—with Revisions through December 2003 808.1
1316—94 Glass Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols, and Alcohol-gasoline Mixtures—with Revisions through May 2006 3404.2.13.1.5
1363—07 Relocatable Power Taps 605.4.1
1975—06 Fire Tests for Foamed Plastics Used for Decorative Purpose 807.4.2.1, 808.2
1994—04 Standard for Luminous Egress Path Marking Systems—with Revisions through February 2005 1024.2.1, 1024.2.3,1024.2.4, 1024.4
2075—07 Standard for Gas and Vapor Detectors and Sensors 2211.7.2.1
2079—04 Tests for Fire Resistance of Building Joint Systems—with Revisions through May 2006 702.1
2085—97 Protected Aboveground Tanks for Flammable and Combustible Liquids— with Revisions through December 1999 202, 3402.1, 3404.2.9.2.3, 3404.2.9.7.5, 3405.3.8.2
2200—04 Stationary Engine Generator Assemblies—with Revisions through July 2004 604.1.1
2208—05 Solvent Distillation Units—with Revisions through December 2006 3405.4.1
2245—06 Below-grade Vaults for Flammable Liquid Storage Tanks 3404.2.8.1
2335—01 Fire Tests of Storage Pallets—with Revisions through September 2004 2308.2.1
     
USC United States Code c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
18 USC Part 1, Chapter 40 Importation, Manufacture, Distribution and Storage of Explosive Materials 3302.1
21 USC Chapter 9 United States Food, Drug and Cosmetic Act 4002.1