Chapter 44 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R102.4.

AAMA American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standards/Specifications for Windows, Doors and Skylights R308.6.9, R609.3, Chapter 11
450—10 Voluntary Performance Rating Method for Mulled Fenestration Assemblies R609.8
506—11 Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products R609.6.1
711—13 Voluntary Specification for Self-adhering Flashing Used for Installation of
Exterior Wall Fenestration Products
R703.1.1, R703.4
712—11 Voluntary Specification for Mechanically Attached Flexible Flashing R703.4
714—12 Voluntary Specification for Liquid Applied Flashing Used to Create a Water-resistive
Seal around Exterior Wall Openings in Buildings
R703.4
AAMA/NPEA/
NSA 2100—12
Specifications for Sunrooms R301.2.1.1

ACI American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
Title Referenced
in code
section number
318—14 Building Code Requirements for Structural Concrete R301.2.2.2.4, R301.2.2.3.4, R402.2, Table R404.1.2(2),
Table R404.1.2(5), Table R404.1.2(6), Table R404.1.2(7),
Table R404.1.2(8), Table R404.1.2(9), R404.1.3, R404.1.3.1,
R404.1.3.3, R404.1.3.4, R404.1.4.2, R404.5.1, R608.1, R608.1.1,
R608.1.2, R608.2, R608.5.1, R608.6.1, R608.8.2, R608.9.2, R608.9.3
332—14 Code Requirements for Residential Concrete Construction R402.2, R403.1, R404.1.3, R404.1.3.4,
R404.1.4.2, R506.1
530—13 Building Code Requirements for Masonry Structures R404.1.2, R606.1, R606.1.1,
R606.12.1, R606.12.2.3.2, R606.12.2.3.1, R703.12
R606.12.3.1530.1—13 Specification for Masonry Structures R404.1.2, R606.1, R606.1.1, R606.2.9, R606.2.12, R606.12.1,
R606.12.2.3.2, R606.12.3.1, 703.12

ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual D—2011 Residential Duct Systems M1601.1, M1602.2
Manual J—2011 Residential Load Calculation—Eighth Edition M1401.3
Manual S—13 Residential Equipment Selection M1401.3

AISI American Iron and Steel Institute
25 Massachusetts Avenue, NW Suite 800
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
AISI S100—12 North American Specification for the Design of Cold-formed
Steel Structural Members, 2012
R505.1.3, R603.6, R608.9.2,
R608.9.3, R804.3.6
AISI S200—12 North American Standard for Cold-formed Steel Framing—General Provisions 2012 R702.3.3
AISI S220—11 North American Standard for Cold-formed Steel Framing—Nonstructural Members R702.3.3
AISI S230—07/
S3-12 (2012)
Standard for Cold-formed Steel Framing—Prescriptive Method
for One- and Two-family Dwellings, 2007 with Supplement 3,
dated 2012 (Reaffirmed 2012)
R301.1.1, R301.2.2.3.1, R301.2.2.3.5, R603.6,
R603.9.4.1, R603.9.4.2, R608.9.2, R608.9.3, Figure 608.9(11), R608.10

ANCE Association of the Electric Sector
Av. Lázaro Cardenas No. 869
Col. Nueva Industrial Vallejo
C.P. 07700 México D.F.
Standard
reference
number
Title Referenced
in code
section number
UL/CSA/ANCE
60335-2—2012
Standard for Household and Similar Electric Appliances, Part 2:
Particular Requirements for Motor-compressors
M1403.1, M1412.1, M1413.1

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A108.1A—99 Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar R702.4.1
A108.1B—99 Installation of Ceramic Tile, Quarry Tile on a Cured
Portland Cement Mortar Setting Bed with Dry-set or Latex Portland Mortar
R702.4.1
A108.4—99 Installation of Ceramic Tile with Organic Adhesives or
Water-Cleanable Tile-setting Epoxy Adhesive
R702.4.1
A108.5—99 Installation of Ceramic Tile with Dry-set Portland
Cement Mortar or Latex Portland Cement Mortar
R702.4.1
A108.6—99 Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting
and -grouting Epoxy
R702.4.1
A108.11—99 Interior Installation of Cementitious Backer Units R702.4.1
A118.1—99 American National Standard Specifications for Dry-set Portland Cement Mortar R702.4.1
A118.3—99 American National Standard Specifications for Chemical-resistant,
Water-cleanable Tile-setting and -grouting Epoxy, and
Water-cleanable Tile-setting Epoxy Adhesive
R702.4.1
A118.4—99 American National Standard Specifications for Latex-Portland Cement Mortar R606.2.10
A136.1—99 American National Standard Specifications for Organic Adhesives for
Installation of Ceramic Tile
R702.4.1
A137.1—2012 American National Standard Specifications for Ceramic Tile R702.4.1
LC1/CSA 6.26—13 Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) Table M1309, G2415.5.3
LC4/CSA 6.32—12 Press-connect Metallic Fittings for Use in Fuel Gas Distribution Systems G2415.10.2
Z21.1—2010 Household Cooking Gas Appliances G2448.1
Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners G2444.1
Z21.10.1/CSA 4.1—12 Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings
of 75,000 Btu per hour or Less
G2449.1
Z21.10.3/CSA 4.3—11 Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings
above 75,000 Btu per hour, Circulating and Instantaneous
G2449.1
Z21.11.2—11 Gas-fired Room Heaters—Volume II—Unvented Room Heaters G2446.1
Z21.15/CSA 9.1—09 Manually Operated Gas Valves for Appliances, Appliance
Connector Valves and Hose End Valves
Table G2421.1.1
Z21.24/CGA 6.10—06 Connectors for Gas Appliances G2423.1
Z21.40.1/
CSA 2.91—96 (R2011)
Gas-fired, Heat-activated Air-conditioning and Heat Pump Appliances G2450.1
Z21.40.2/
CSA 2.92—96 (R2011)
Air-conditioning and Heat
Pump Appliances (Thermal Combustion)
G2450.1
Z21.42—2014 Gas-fired Illuminating Appliances G2451.1
Z21.47/CSA 2.3—12 Gas-fired Central Furnaces G2443.1
Z21.50/CSA 2.22—12 Vented Gas Fireplaces G2435.1
Z21.56/CSA 4.7—13 Gas-fired Pool Heaters G2442.1
Z21.58—95/CSA 1.6—13 Outdoor Cooking Gas Appliances G2448.1
Z21.60/CSA 2.26—12 Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces G2433.1
Z21.75/CSA 6.27—07 Connectors for Outdoor Gas Appliances and Manufactured Homes G2423.1
Z21.80—11 Line Pressure Regulators G2422.1
ANSI/CSA America Stationary Fuel Cell Power Systems M1905.1
FCI—12
Z21.84—12
Manually Listed, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel-burning Fireplaces
G2433.1, G2433.2
Z21.86—08 Gas-fired Vented Space Heating Appliances G2437.1, G2438.1, G2447.1
Z21.88/CSA 2.33—14 Vented Gas Fireplace Heaters G2436.1
Z21.91—07 Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters G2446.7.1
Z21.97—12 Outdoor Decorative Appliances G2454.1
Z83.6—90 (R1998) Gas-fired Infrared Heaters G2452.1
Z83.8/CSA 2.6—09 Gas-fired Unit Heaters, Gas Packaged Heaters, Gas Utility Heaters and Gas-fired Duct Furnaces G2445.1
Z83.19—01 (R2009) Gas-fuel High-intensity Infrared Heaters G2452.1
Z83.20—08 Gas-fired Low-intensity Infared Heaters Outdoor Decorative Appliances G2452.1
Z97.1—2014 Safety Glazing Materials Used in Buildings—Safety Performance Specifications
and Methods of Test
R308.1.1, R308.3.1
Z223.1—08 National Fuel-Gas Standard G2405.1

APA APA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
Title Referenced
in code
section number
ANSI/A190.1—12 Structural Glued-laminated Timber R502.1.3, R602.1.3, R802.1.2
ANSI/APA PRP 210—08 Standard for Performance-rated Engineered Wood Siding R604.1, Table R703.3(1), R703.3.3
ANSI/APA PRG 320—2012 Standard for Performance-rated Cross Laminated Timber R502.1.6, R602.1.6, R802.1.6
ANSI/APA PRR 410—2011 Standard for Performance-rated Engineered Wood Rim Boards R502.1.7, R602.1.7, R802.1.7
APA E30—11 Engineered Wood Construction Guide Table R503.2.1.1(1), R503.2.2,
R803.2.2, R803.2.3

ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
Standard
reference
number
Title Referenced
in code
section number
5—13 Building Code Requirements for Masonry Structures R404.1.2, R606.1, R606.1.1, R606.12.1,
R606.12.2.3.1, R606.12.2.3.2, R606.12.3.1, R703.12
6—13 Specification for Masonry Structures R404.1.2, R606.1, R606.1.1, R606.2.9,
R606.2.12, R606.12.1, R606.12.2.3.1, R606.12.2.3.2,
R606.12.3.1, R703.12
7—10 Minimum Design Loads for Buildings and Other Structures
with Supplement No. 1
Table R608.6(1), Table R608.6(2), Table R608.6(3),
Table R608.6(4), Table R608.7(1A), Table R608.7(1B),
Table R608.7(1C), R608.9.2, R608.9.3, R609.2, AH107.4.3
24—14 Flood-resistant Design and Construction R102.4.1, R301.2.4, R322.1,
R322.1.1, R322.1.6, R322.2.2, R322.3.3
32—01 Design and Construction of Frost-protected Shallow Foundations R403.1.4.1

ASHRAE American Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2013 ASHRAE Handbook of Fundamentals Chapter 11
34—2013 Designation and Safety Classification of Refrigerants M1411.1

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General-purpose (Inch) G2415.9
B16.33—2012 Manually Operated Metallic Gas Valves for Use in Gas Piping
Systems up to 125 psig (Sizes 1/2 through 2)
Table G2421.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in
Above-ground Piping Systems up to 5 psi
Table G2421.1.1
B36.10M—2004 Welded and Seamless Wrought-steel Pipe G2415.4.2
BPVC—2010/2011 addenda ASME Boiler and Pressure Vessel Code (2007 Edition) M2001.1.1
CSD-1—2011 Controls and Safety Devices for Automatically Fired Boilers M2001.1.1

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
Title Referenced
in code
section number
A36/A36M—08 Specification for Carbon Structural Steel R606.15, R608.5.2.2
A53/A53M—12 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless R407.3,
Table M2101.1, G2415.4.2
A106/A106M—11 Specification for Seamless Carbon Steel Pipe for High-temperature Service Table M2101.1, G2415.4.2
A153/A153M—09 Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware R317.3, Table R606.3.4.1
A167—99 (2009) Specification for Stainless and Heat-resisting Chromium-nickel
Steel Plate, Sheet and Strip
Table R606.3.4.1
A240/A240M—13A Standard Specification for Chromium and Chromium-nickel Stainless
Steel Plate, Sheet and Strip for Pressure Vessels and for General Applications
Table R905.10.3(1)
A254—97 (2007) Specification for Copper Brazed Steel Tubing Table M2101.1, G2415.5.1
A307—12 Specification for Carbon Steel Bolts and Studs, 60,000 psi Tensile Strength R608.5.2.2
A463/A463M—10 Standard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process Table R905.10.3(2)
A539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines M2202.1
A615/A615M—12 Specification for Deformed and Plain Billet-steel Bars for
Concrete Reinforcement
R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1
A641/A641M—09a Specification for Zinc-coated (Galvanized) Carbon Steel Wire Table R606.3.4.1
A653/A653M—11 Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron
Alloy-coated Galvanized) by the Hot-dip Process
R317.3.1, R505.2.2,
R603.2.2, Table R606.3.4.1,
R608.5.2.3, R804.2.2, R804.2.3, Table R905.10.3(1),
Table R905.10.3(2), M1601.1.1
A706/A706M—09B Specification for Low-alloy Steel Deformed and Plain
Bars for Concrete Reinforcement
R402.3.1, R403.1.3.5.1, R404.1.3.3.7.1, R608.5.2.1
A755/A755M—2011 Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and
Prepainted by the Coil-coating Process for Exterior Exposed Building Products
Table R905.10.3(2)
A792/A792M—10 Specification for Steel Sheet, 55% Aluminum-zinc Alloy-coated
by the Hot-dip Process
R505.2.2, R603.2.2,
R608.5.2.3, R804.2.2, Table 905.10.3(2)
A875/A875M—13 Specification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated
by the Hot-dip Process
R608.5.2.3, Table R905.10.3(2)
A924/ 924M—13 Standard Specification for General Requirements for Steel Sheet,
Metallic-coated by the Hot-Dip Process
Table R905.10.3(1)
A996/A996M—2009b Specifications for Rail-steel and Axle-steel Deformed Bars
for Concrete Reinforcement
Table R404.1.2(9), R402.3, R403.1.3.5.1,
R404.1.3.3.7.1, R608.5.2.1, Table R608.5.4(2)
A1003/A1003M—13A Standard Specification for Steel Sheet, Carbon, Metallic and
Nonmetallic-coated for Cold-formed Framing Members
R505.2.1, R505.2.2, R603.2.1,
R603.2.2, R804.2.1
B88—09 Specification for Seamless Copper Water Tube Table M2101.1, G2415.5.2
B101—12 Specification for Lead-coated Copper Sheet and Strip for Building Construction Table R905.2.8.2,
Table R905.10.3(1)
B135—10 Specification for Seamless Brass Tube Table M2101.1
B209—10 Specification for Aluminum and Aluminum-alloy Sheet and Plate Table 905.10.3(1)
B227—10 Specification for Hard-drawn Copper-clad Steel Wire R606.15
B251—10 Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
Table M2101.1
B302—12 Specification for Threadless Copper Pipe, Standard Sizes Table M2101.1, Table P2906.4,
Table P2906.5, Table P3002.1(1)
B306—09 Specification for Copper Drainage Tube (DWV) Table M2101.1, Table P3002.1(1),
Table P3002.1(2)
B370—12 Specification for Copper Sheet and Strip for Building Construction Table R905.2.8.2, Table R905.10.3(1)
B695—04 (2009) Standard Specification for Coatings of Zinc Mechanically
Deposited on Iron and Steel
R317.3.1, R317.3.3
B813—10 Specification for Liquid and Paste Fluxes for Soldering Applications
of Copper and Copper Alloy Tube
Table M2101.1, M2103.3
B828—02 (2010) Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
M2103.3
C5—10 Specification for Quicklime for Structural Purposes R702.2.1
C22/C22M—00 (2010) Specification for Gypsum R702.2.1, R702.3.1
C27—98 (2008) Specification for Standard Classification of Fireclay
and High-alumina Refractory Brick
R1001.5
C28/C28M—10 Specification for Gypsum Plasters R702.2.1
C33/C33M—13 Specification for Concrete Aggregates R403.4.1
C34—12 Specification for Structural Clay Load-bearing Wall Tile R606.2.2
C35/C35M—1995 (2009) Specification for Inorganic Aggregates for Use in Gypsum Plaster R702.2.1
C55—2011 Specification for Concrete Building Brick R202, R606.2.1
C56—12 Standard Specification for Structural Clay Nonloadbearing Tile R606.2.2
C59/C59M—00 (2011) Specification for Gypsum Casting Plaster and Molding Plaster R702.2.1
C61/C61M—00 (2011) Specification for Gypsum Keene's Cement R702.2.1
C62—13 Standard Specification for Building Brick (Solid Masonry
Units Made from Clay or Shale)
R202, R606.2.2
C73—10 Specification for Calcium Silicate Face Brick (Sand Lime Brick) R202, R606.2.1
C90—13 Specification for Load-bearing Concrete Masonry Units 606.2.1
C91—12 Specification for Masonry Cement R702.2.2
C94/C94M—13 Standard Specification for Ready-mixed Concrete R404.1.3.3.2, R608.5.1.2
C126—13 Standard Specification for Ceramic Glazed Structural Clay
Facing Tile, Facing Brick, and Solid Masonry Units
R606.2.2
C143/C143M—12 Test Method for Slump of Hydraulic Cement Concrete R404.1.3.3.4, R608.5.1.9
C145—85 Specification for Solid Load-bearing Concrete Masonry Units R202
C150—12 Specification for Portland Cement R608.5.1.1, R702.2.2
C199—84 (2011) Test Method for Pier Test for Refractory Mortar R1001.5, R1001.8, R1003.12
C203—05a (2012) Standard Test Methods for Breaking Load and Flexural
Properties of Block-type Thermal Insulation
Table R610.3.1
C207—06 (2011) Specification for Hydrated Lime for Masonry Purposes Table R606.2.7
C208—12 Specification for Cellulosic Fiber Insulating Board R602.1.10, Table R602.3(1), Table R906.2
C212-10 Standard Specification for Structural Clay Facing Tile R602.2.2
C216—13 Specification for Facing Brick (Solid Masonry Units
Made from Clay or Shale)
R202, R606.2.2
C270—12a Specification for Mortar for Unit Masonry R606.2.7, R606.2.10
C272/C272M—12 Standard Test Method for Water Absorption of Core Materials for
Sandwich Constructions
Table R610.3.1
C273/C273M—11 Standard Test Method for Shear Properties of Sandwich Core Materials Table R610.3.1
C315—07 (2011) Specification for Clay Flue Liners and Chimney Pots R1001.8, R1003.11.1,
Table R1003.14(1), G2426.12
C406/C406M—2010 Specifications for Roofing Slate R905.6.4
C411—11 Test Method for Hot-surface Performance of High-temperature Thermal Insulation M1601.3
C475/C475—12 Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard R702.3.1
C476—10 Specification for Grout for Masonry R606.2.11
C503—10 Standard Specification for Marble Dimension Stone R606.2.4
C514—04 (2009)el Specification for Nails for the Application of Gypsum Wallboard R702.3.1
C552—12b Standard Specification for Cellular Glass Thermal Insulation Table R906.2
C557—03 (2009)e01 Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing R702.3.1
C578—12b Specification for Rigid, Cellular Polystyrene Thermal Insulation R316.7, R403.3, R610.3.1,
R703.11.2.1, Table R703.15.1, Table R703.15.2,
Table R703.16.1, Table R703.16.2, Table R906.2
C587—04(2009) Specification for Gypsum Veneer Plaster R702.2.1
C595/C595M—13 Specification for Blended Hydraulic Cements R608.5.1.1, R702.2.2
C615/C615M—11 Standard Specification for Granite Dimension Stone R606.2.4
C616/C615M—10 Standard Specification for Quartz Dimension Stone R606.2.4
C629—10 Standard Specification for Slate Dimension Stone R606.2.4
C631—09 Specification for Bonding Compounds for Interior Gypsum Plastering R702.2.1
C645—13 Specification for Nonstructural Steel Framing Members R702.3.3
C652—13 Specification for Hollow Brick (Hollow Masonry Units
Made from Clay or Shale)
R202, R606.2.2
C685/C685M—11 Specification for Concrete Made by Volumetric
Batching and Continuous Mixing
R404.1.3.3.2, R608.5.1.2
C728—05 (2013) Standard Specification for Perlite Thermal Insulation Board Table R906.2
C744—11 Standard Specification for Prefaced Concrete and Calcium Silicate Masonry Units R606.2.1
C836/C836M—12 Specification for High Solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Separate Wearing Course
R905.15.2
C843—99 (2012) Specification for Application of Gypsum Veneer Plaster R702.2.1
C844—04 (2010) Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster R702.2.1
C847—12 Specification for Metal Lath R702.2.1, R702.2.2
C887—05 (2010) Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar R406.1, R606.2.8
C897—05 (2009) Specification for Aggregate for Job-mixed Portland Cement-based Plasters R702.2.2
C920—11 Standard Specification for Elastomeric Joint Sealants R406.4.1
C926—13 Specification for Application of Portland Cement-based Plaster R702.2.2, R702.2.2.1, R703.7,
R703.7.2.1, R703.7.4
C933—13 Specification for Welded Wire Lath R702.2.1, R702.2.2
C946—10 Standard Practice for Construction of Dry-Stacked, Surface-Bonded Walls R606.2.8
C954—11 Specification for Steel Drill Screws for the Application of Gypsum Panel
Products or Metal Plaster Bases to Steel Studs from 0.033 in (0.84 mm) or
to 0.112 in. (2.84 mm) in Thickness
R505.2.5, R603.2.5,
R702.3.5.1, R804.2.5
C955—11C Specification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks),
and Bracing or Bridging for Screw Application of Gypsum Panel Products
and Metal Plaster Bases
R702.3.3
C957—10 Specification for High-solids Content, Cold Liquid-applied Elastomeric
Waterproofing Membrane for Use with Integral Wearing Surface
R905.15.2
C1002—07 Specification for Steel Drill Screws for the Application of Gypsum Panel Products
or Metal Plaster Bases
R702.3.1, R702.3.5.1
C1029—13 Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation R905.14.2
C1032—06 (2011) Specification for Woven Wire Plaster Base R702.2.1, R702.2.2
C1047—10a Specification for Accessories for Gypsum Wallboard
and Gypsum Veneer Base
R702.2.1, R702.2.2, R702.3.1
C1063—12D Specification for Installation of Lathing and Furring to Receive Interior and
Exterior Portland Cement-based Plaster
R702.2.2, R703.7
C1088—13 Standard Specification for Thin Veneer Brick Units Made from Clay or Shale R606.2.2
C1107/C1107M—13 Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink) R402.3.1
C1116/C116M—10A Standard Specification for Fiber-reinforced Concrete and Shotcrete R402.3.1
C1157—11/C1157M—11 Standard Performance Specification for Hydraulic Cement R608.5.1.1
C1167—11 Specification for Clay Roof Tiles R905.3.4
C1177/C1177M—08 Specification for Glass Mat Gypsum Substrate for Use as Sheathing R702.3.1, Table 906.2
C1178/C1178M—11 Specification for Glass Mat Water-resistant Gypsum Backing Panel R702.3.1, R702.3.7, Table R702.4.2
C1186—08 (2012) Specification for Flat Nonasbestos Fiber Cement Sheets R703.10.1, R703.10.2
C1261—10 Specification for Firebox Brick for Residential Fireplaces R1001.5, R1001.8
C1278/C1278M—
07a (2011)
Specification for Fiber-reinforced Gypsum Panels R702.3.1, R702.3.7, Table R702.4.2, Table R906.2
C1283—11 Practice for Installing Clay Flue Lining R1003.9.1, R1003.12
C1288—99 (2010) Standard Specification for Discrete Nonasbestos
Fiber-cement Interior Substrate Sheets
Table R503.2.1.1(1), Table R503.2.1.1(2),
Table 602.3(2), Table R702.4.2
C1289—13e1 Standard Specification for Faced Rigid Cellular Polyisocyanurate
Thermal Insulation Board
R316.7, R703.11.2.1, Table R703.15.1, Table R703.15.2,
Table R703.16.1, Table R703.16.2, Table R906.2
C1325—08b Standard Specification for Nonasbestos Fiber-mat Reinforced Cement
Interior Substrate Sheets Backer Units
Table R702.4.2
C1328/C1328M—12 Specification for Plastic (Stucco) Cement R702.2.2
C1364—10B Standard Specification for Architectural Cast Stone R606.2.5
C1386—07 Standard Specification for Precast Autoclaved Aerated Concrete (AAC) Wall
Construction Units
R606.2.3
C1396/C1396M—2013 Specification for Gypsum Board Table R602.3(1), R702.2.1, R702.2.2, R702.3.1, R702.3.7
C1405—12 Standard Specification for Glazed Brick (Single Fired, Brick Units) R606.2.2
C1492—03 (2009) Specification for Concrete Roof Tile R905.3.5
C1513—2013 Standard Specification for Steel Tapping Screws for Cold-formed
Steel Framing Connections
R505.2.5, R603.2.5, R702.3.8.1, Table R703.3(2), R804.2.5
Table R703.16.1, Table R703.16.2
C1634—11 Standard Specification for Concrete Facing Brick R606.2.1
C1658/C1658M—12 Standard Specification for Glass Mat Gypsum Panels R702.3.1
C1668—12 Standard Specification for Externally Applied Reflective Insulation Systems
on Rigid Duct in Heating, Ventilation, and Air Conditioning (HVAC) Systems
M1601.3
D41—05 Specification for Asphalt Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2, Table R905.11.2
D43—00 (2006) Specification for Coal Tar Primer Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D226/D226M—09 Specification for Asphalt-saturated (Organic Felt)
Used in Roofing and Waterproofing
R703.2, R905.1.1, Table R905.1.1(1),
R905.8.4, Table R905.9.2
D227/D227M—03 (2011)e1 Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing Table R905.9.2
D312—00 (2006) Specification for Asphalt Used in Roofing Table R905.9.2
D422—63 (2007) Test Method for Particle-size Analysis of Soils R403.1.9.1
D449—03 (2008) Specification for Asphalt Used in Dampproofing and Waterproofing R406.2
D450—07 Specification for Coal-tar Pitch Used in Roofing, Dampproofing
and Waterproofing
Table R905.9.2
D635—06 Test Method for Rate of Burning and/or Extent and Time of Burning
of Self-supporting Plastics in a Horizontal Position
R316.8.1.2
D1227—95 (2007) Specification for Emulsified Asphalt Used as a Protective
Coating for Roofing
Table R905.9.2, Table R905.11.2, R905.15.2
D1248—12 Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable M1601.1.2
D1621—10 Standard Test Method for Compressive Properties of Rigid Cellular Plastics Table R610.3.1
D1622—08 Standard Test Method for Apparent Density of Rigid Cellular Plastics Table R610.3.1
D1623—09 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
Table R610.3.1
D1693—2013 Test Method for Environmental Stress-cracking of Ethylene Plastics Table M2101.1
D1784—11 Standard Specification for Rigid Poly (Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds
M1601.1.2
D1863/D1863M—05
(2011)e1
Specification for Mineral Aggregate Used in Built-up Roofs Table R905.9.2
D1929—96 Test Method for Determining Ignition Properties of Plastics R316.8.1.2
D1970/D1970M—2013 Specification for Self-adhering Polymer Modified Bitumen
Sheet Materials Used as Steep Roofing Underlayment for
Ice Dam Protection
R905.1.1, R905.2.8.2
D2126—09 Standard Test Method for Response of Rigid Cellular Plastics
to Thermal and Humid Aging
Table R610.3.1
D2178—04 Specification for Asphalt Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D2412—11 Test Method for Determination of External Loading Characteristics of
Plastic Pipe by Parallel-plate Loading
M1601.1.2
D2447—03 Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80,
Based on Outside Diameter
Table M2101.1
D2513—2013e1 Specification for Thermoplastic Gas Pressure Pipe,
Tubing and Fittings
Table M2101.1, G2415.6,
G2415.6.1, G2415.11, G2415.17.2
D2559—12A Standard Specification for Adhesives for Bonded Structural Wood
Products for Use Under Exterior (West Use) Exposure Conditions
R610.3.3
D2626/
D2626M—04 (2012)e1
Specification for Asphalt-saturated and Coated Organic Felt Base
Sheet Used in Roofing
R905.3.3, Table R905.9.2
D2657—07 Standard Practice for Heat Fusion-joining of Polyolefin Pipe Fittings M2105.11.1
D2683—2010e1 Specification for Socket-type Polyethylene Fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
Table M2105.5, M2105.11.1
D2822/
D2822M—05 (2011)e1
Specification for Asphalt Roof Cement, Asbestos Containing Table R905.9.2
D2823/
D2823—05 (2011)e1
Specification for Asphalt Roof Coatings, Asbestos Containing Table R905.9.2
D2824—06 (2012)e1 Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered,
Asbestos Fibered and Fibered without Asbestos
Table R905.9.2, Table R905.11.2
D2843—99 Test for Density of Smoke from the Burning or Decomposition of Plastics R316.8.1.2
D2843—01 Test for Density of Smoke from the Burning of Self-supporting Plastics
in a Horizontal Position
R316.8.1.2
D2846/D2846M—09BE1 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Hot- and Cold-water Distribution Systems
Table M2101.1
D2898—10 Test Methods for Accelerated Weathering of Fire-retardant-treated
Wood for Fire Testing
R802.1.5.4, R802.1.5.8
Table P3002.2, Table P3002.3, Table AG101.1
D3019—08 Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered,
Asbestos Fibered and Nonasbestos Fibered
Table R905.9.2, Table R905.11.2
D3035—2012e1 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On
Controlled Outside Diameter
Table M2105.4
D3161/D3161M—2013 Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method) R905.2.4.1,
Table R905.2.4.1
D3201—2013 Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products R802.1.5.9
D3261—12 Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for
Polyethylene (PE) Plastic Pipe and Tubing
Table M2105.5, M2105.11.1
D3309—96a (2002) Specification for Polybutylene (PB) Plastic Hot- and Cold-water Distribution System Table M2101.1
D3350—2012e1 Specification for Polyethylene Plastic Pipe and Fitting Materials Table M2101.1
D3462/D3462M—10A Specification for Asphalt Shingles Made From Glass Felt and
Surfaced with Mineral Granules
R905.2.4
D3468—99 (2006)e01 Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene
Used in Roofing and Waterproofing
R905.15.2
D3679—11 Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding R703.11
D3737—2012 Practice for Establishing Allowable Properties for Structural Glued
Laminated Timber (Glulam)
R502.1.3, R602.1.3, R802.1.2
D3747—79 (2007) Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation Table R905.9.2,
Table R905.11.2
D3909/D3909M
—97b (2012)e1
Specification for Asphalt Roll Roofing (Glass Felt)
Surfaced with Mineral Granules
R905.2.8.2, R905.5.4, Table R905.9.2
D4022/D4022M—2007
(2012)e1
Specification for Coal Tar Roof Cement, Asbestos Containing Table R905.9.2
D4318—10 Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils R403.1.9.1
D4434/D4434M—12 Specification for Poly (Vinyl Chloride) Sheet Roofing R905.13.2
D4479/D4479M—07
(2012)e1
Specification for Asphalt Roof Coatings-asbestos-free Table R905.9.2
D4586/D4586M—07
(2012)e1
Specification for Asphalt Roof Cement-asbestos-free Table R905.9.2
D4601/D4601M—04
(2012)e1
Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing Table R905.9.2
D4637/D4637M—2013 Specification for EPDM Sheet Used in Single-ply Roof Membrane R905.12.2
D4829—11 Test Method for Expansion Index of Soils R403.1.9.1
D4869/D4869M—05
(2011)e01
Specification for Asphalt-saturated (Organic Felt) Underlayment
Used in Steep Slope Roofing
R905.1.1, Table R905.1.1(1)
D4897/
D4897M—01 (2009)
Specification for Asphalt Coated Glass-fiber Venting
Base Sheet Used in Roofing
Table R905.9.2
D4990—97a (2005)e01 Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing Table R905.9.2
D5019—07a Specification for Reinforced Nonvulcanized Polymeric
Sheet Used in Roofing Membrane
R905.12.2
D5055—2013 Specification for Establishing and Monitoring Structural
Capacities of Prefabricated Wood I-joists
R502.1.2
D5456—2013 Standard Specification for Evaluation of Structural
Composite Lumber Products
R502.1.5, R602.1.5, R802.1.7
D5516—09 Test Method for Evaluating the Flexural Properties of Fire-retardant-treated
Softwood Plywood Exposed to the Elevated Temperatures
R802.1.5.7
D5643/D5643M—06
(2012)e1
Specification for Coal Tar Roof Cement Asbestos-free Table R905.9.2
D5664—10 Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated
Temperatures on Strength Properties of Fire-retardant-treated Lumber
R802.1.5.7
D5665—99a (2006) Specification for Thermoplastic Fabrics Used in Cold-applied
Roofing and Waterproofing
Table R905.9.2
D5726—98 (2005) Specification for Thermoplastic Fabrics Used in Hot-applied
Roofing and Waterproofing
Table R905.9.2
D6083—05e01 Specification for Liquid-applied Acrylic Coating Used in Roofing Table R905.9.2, Table R905.11.2,
Table R905.14.3, R905.15.2
D6162—2000a (2008) Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using a Combination of Polyester and Glass Fiber Reinforcements
Table R905.11.2
D6163—00 (2008) Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet
Materials Using Glass Fiber Reinforcements
Table R905.11.2
D6164/D6164M—11 Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D6222/D6222M—11 Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using Polyester Reinforcements
Table R905.11.2
D6223/D6223M—02
(2011)e1
Specification for Atactic Polypropylene (APP) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcement
Table R905.11.2
D6298—05e1 Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS)
Modified Bituminous Sheets with a Factory Applied Metal Surface
Table R905.11.2
D6305—08 Practice for Calculating Bending Strength Design Adjustment Factors for
Fire-retardant-treated Plywood Roof Sheathing
R802.1.5.6
D6380—03 (2009) Standard Specification for Asphalt Roll Roofing (Organic Felt) Table R905.1.1(1), R905.2.8.2,
R905.5.4
D6694—08 Standard Specification for Liquid-applied Silicone Coating Used in Spray
Polyurethane Foam Roofing Systems
Table R905.14.3, R905.15.2
D6754/D6745M—10 Standard Specification for Ketone-ethylene-ester-based Sheet Roofing R905.13.2
D6757—2013 Standard Specification for Inorganic Underlayment for
Use with Steep Slope Roofing Products
Table R905.1.1(1), R905.1.1
D6841—08 Standard Practice for Calculating Design Value Treatment Adjustment
Factors for Fire-retardant-treated Lumber
R802.1.5.7
D6878/D6878—11a Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing R905.13.2
D6947—07 Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating
Used in Spray Polyurethane Foam Roofing System
Table R905.14.3, R905.15.2
D7032—10a Standard Specification for Establishing Performance Ratings for Wood-plastic
Composite Deck Boards and Guardrail Systems (Guards or Handrails)
R507.3, R507.3.1, 507.3.4, 507.3.4
D7158—D7158M—2011 Standard Test Method for Wind Resistance of Sealed Asphalt Shingles
(Uplift Force/Uplift Resistance Method)
R905.2.4.1, Table R905.2.4.1
D7254—07 Standard Specification for Polypropylene (PP) siding Table R703.3(1), R703.14
D7425/D7425M—11 Standard Specification for Spray Polyurethane Foam Used for Roofing Application R905.14.2
D7672—2012 Standard Specification for Evaluating Structural Capacities
of Rim Board Products and Assemblies
R502.1.7, R602.1.7, R802.1.7
D7793—13 Standard Specification for Insulated Vinyl Siding R703.13, Table R703.3(1)
E84—2013a Test Method for Surface Burning Characteristics
of Building Materials
R202, R302.9.3, R302.9.4, R302.10.1, R302.10.2,
R316.3, R316.5.9, R316.5.11, R507.3.2, R802.1.5, M1601.3
E96/E96M—2013 Test Method for Water Vapor Transmission of Materials R202, Table R610.3.1, M1411.6
E108—2011 Test Methods for Fire Tests of Roof Coverings R302.2.2, R902.1
E119—2012a Test Methods for Fire Tests of Building Construction and Materials Table R302.1, R302.2.2,
R302.3, R302.4.1, R302.11.1
E136—2012 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C R202, R302.11
E283—04 Test Method for Determining the Rate of Air Leakage Through Exterior
Windows, Curtain Walls and Doors Under Specified Pressure
Differences Across the Specimen
Chapter 11
E330—02 Test Method for Structural Performance of Exterior Windows,
Curtain Walls and Doors by Uniform Static Air Pressure Difference
R609.5, R703.1.2
E331—00 (2009) Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain
Walls by Uniform Static Air Pressure Difference
R703.1.1
E774—97 Standard Practice for Evaluating Solar Absorptive Materials for Thermal Applications NF1113.1
E814—2013 Test Method for Fire Tests of Through-penetration Firestops R302.4.1.2
E970—2010 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation
Using a Radiant Heat Energy Source
R302.10.5
E1509—12 Standard Specification for Room Heaters, Pellet Fuel-burning Type M1410.1
E1602—03 (2010)e1 Guide for Construction of Solid Fuel Burning Masonry Heaters R1002.2
E1886—05 Test Method for Performance of Exterior Windows, Curtain Walls, Doors
and Storm Shutters Impacted by Missile(s) and Exposed
to Cyclic Pressure Differentials
R609.6.1
E1996—2012a Standard Specification for Performance of Exterior Windows, Curtain
Walls, Doors and Impact Protective Systems Impacted by
Windborne Debris in Hurricanes
R301.2.1.2
E2178—2013 Standard Test Method for Air Permeance of Building Materials R202
E2231—09 Standard Practice for Specimen Preparation and Mounting of Pipe and
Duct Insulation Materials to Assess Surface Burning Characteristics
M1601.3
E2273—03 (2011) Standard Test Method for Determining the Drainage Efficiency of Exterior
Insulation and Finish Systems (EIFS) Clad Wall Assemblies
R703.1.1, R703.9.1
E2568—09e1 Standard Specification for PB Exterior Insulation and Finish Systems R703.9.1
E2570—07 Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings
Used Under Exterior Insulation and Finish Systems (EIFS) with Drainage
R703.9.2
E2634—11 Standard Specification for Flat Wall Insulating Concrete Form (ICF) Systems R404.1.3.3.6.1, R608.4.4
F876—13 Specification for Cross-linked Polyethylene (PEX) Tubing Table M2101.1
F877—11A Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and
Cold-water Distribution Systems
Table M2101.1
F1055—13 Specification for Electrofusion Type Polyethylene Fittings for Outside
Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing
Table M2105.5,
M2105.11.2
F1281—11 Specification for Cross-linked Polyethylene/Aluminum/Cross-linked
Polyethylene (PEX-AL-PEX) Pressure Pipe
Table M2101.1
F1282—10 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
Table M2101.1
F1554—07a Specification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength R608.5.2.2
F1667—11A e1 Specification for Driven Fasteners, Nails, Spikes and Staples R317.3, R703.3.2, Table R703.15.1,
Table R703.15.2, R905.2.5
F1924—12 Standard Specification for Plastic Mechanical Fittings for Use
on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing
M2105.11.1
F1960—12 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with
Cross-linked Polyethylene (PEX) Tubing
Table M2101.1
F1970—12 Standard Specification for Special Engineered Fittings, Appurtenances or Valves for
Use in Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
M2105.5
F1973—08 Standard Specification for Factory Assembled Anodeless Risers and Transition
Fittings in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems
G2415.15.2
F2090—10 Specification for Window Fall Prevention Devices—with Emergency
Escape (Egress) Release Mechanisms
R310.1.1, R312.2.1, R312.2.2
F2098—08 Standard Specification for Stainless Steel Clamps for Securing SDR9
Cross-linked Polyethylene (PEX) Tubing to Metal Insert and
Plastic Insert Fittings
Table M2101.1
F2389—10 Standard for Pressure-rated Polypropylene (PP) Piping Systems Table M2105.12.1
F2623—08 Standard Specification for Polyethylene of Raised Temperature
(PE-RT) SDRG Tubing
Table M2101.1
F2735—09 Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked
Polyethylene (PEX) and Polyethylene of Raised Temperature (PE-RT) Tubing
Table M2101.1
F2769—10 Polyethylene or Raised Temperature (PE-RT) Plastic Hot and
Cold-Water Tubing and Distribution Systems
Table M2101.1
F2806—10 Standard Specification for Acrylonitrile-butadiene-styrene (ABS) Plastic Pipe
(Metric SDR-PR)
Table M2101.1
F2969—12 Standard Specification for Acrylonitrile-butadiene-styrene
(ABS) IPS Dimensioned Pressure Pipe
Table M2101.1

AWC American Wood Council
222 Catocin Circle, Suite 201
Leesburg, VA 20175
Standard
reference
number
Title Referenced
in code
section number
AWC STJR—2015 Span Tables for Joists and Rafters R502.3, R802.4, R802.5
AWC WFCM—2015 Wood Frame Construction Manual for One- and
Two-family Dwellings
R301.1.1, R602.10.8.2,
R608.9.2, Figure R608.9(9), R608.10
ANSI AWC NDS—2015 National Design Specification (NDS) for Wood Construction—
with 2015 Supplement
R404.2.2, R502.2, Table R503.1, R602.3, R608.9.2,
Table R703.15.1, Table R703.15.2, R802.2
ANSI/AWC PWF—2015 Permanent Wood Foundation Design Specification R317.3.2, R401.1, R404.2.3

AWPA American Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
Title Referenced
in code
section number
C1—03 All Timber Products—Preservative Treatment by Pressure Processes R902.2
M4—11 Standard for the Care of Preservative-treated Wood Products R317.1.1
U1—14 USE CATEGORY SYSTEM: User Specification for Treated Wood
Except Section 6 Commodity Specification H
R317.1, R402.1.2, R504.3,
Table R905.8.5

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
Standard
reference
number
Title Referenced
in code
section number
ANSI/AWS
A5.31M/A5.31—2012
Specification for Fluxes for Brazing
and Braze Welding Edition: 2nd
M2103.3, M2202.2, M2103.3

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C903—05 Polyethylene-aluminum-polyethylene & Crosslinked Polyethylene
Composite Pressure Pipe, 1/2 in. (12 mm) through 2 in. (50 mm), for Water Service
Table M2101

CEN European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
reference
number
Title Referenced
in code
section number
EN 15250-2007 Slow Heat Release Appliances Fired by Solid Fuel Requirements and Test Methods R1002.5

CGSB Canadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
Title Referenced
in code
section number
CAN/CGSB-37.54—95 Polyvinyl Chloride Roofing and Waterproofing Membrane R905.13.2
37-GP-52M—(1984) Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric R905.12.2
37-GP-56M—(1980) Membrane, Modified Bituminous, Prefabricated and Reinforced for
Roofing—with December 1985 Amendment
Table R905.11.2

CPA Composite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
Title Referenced
in code
section number
ANSI A135.4—2012 Basic Hardboard Table R602.3(2)
ANSI A135.5—2012 Prefinished Hardboard Paneling R702.5
A208.1—2009 Particleboard R503.3.1, R602.1.9, R605.1

CPSC Consumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
Title Referenced
in code
section number
16 CFR, Part 1201—(2002) Safety Standard for Architectural Glazing R308.1.1, R308.3.1, Table R308.3.1(1)
16 CFR, Part 1209—(2002) Interim Safety Standard for Cellulose Insulation R302.10.3
16 CFR, Part 1404—(2002) Cellulose Insulation R302.10.3

CSA CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
North American Fenestration Standard/Specification for
Windows, Doors and Unit Skylights
R308.6.9, R609.3, Chapter 11
ANSI/CSA America Stationary Fuel Cell Power Systems M1903.1
B137.9—13 Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
Table M2101.1
B137.10—13 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PE-AL-PE)
Composite Pressure Pipe Systems
Table M2101.1
CSA C448 Series-02-
CAN/CSA—2002
Design and Installation of Earth Energy Systems—
First Edition; Update 2: October 2009; Consolidated Reprint 10/2009
Table M2105.4, Table M2105.5
O325—07 Construction Sheathing R503.2.1, R602.1.8, R604.1, R803.2.1
O437-Series—93 Standards on OSB and Waferboard (Reaffirmed 2006) R503.2.1, R602.1.8, R604.1, R803.2.1
UL/CSA/ANCE
60335-2-40—2012
Standard for Household and Similar Electrical Appliances,
Part 2: Particular Requirements for Motor-compressors
M1403.1, M1412.1, M1413.1

CSSB Cedar Shake & Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
Title Referenced
in code
section number
CSSB—97 Grading and Packing Rules for Western Red Cedar Shakes and Western Red
Shingles of the Cedar Shake and Shingle Bureau
R702.6, R703.6, Table R905.7.4, Table R905.8.5

DASMA Door and Access Systems Manufacturers Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
Title Referenced
in code
section number
108—12 Standard Method for Testing Garage Doors: Determination of Structural
Performance Under Uniform Static Air Pressure Difference
R609.14

DOC United States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
Standard
reference
number
Title Referenced
in code
section number
PS 1—09 Structural Plywood R404.2.1, Table R404.2.3, R503.2.1,
R602.1.8, R604.1, R610.3.2, R803.2.1
PS 2—10 Performance Standard for Wood-based Structural-use Panels R404.2.1, Table R404.2.3, R503.2.1,
R602.1.8, R604.1, R610.3.2,
Table 610.3.2, R803.2.1
PS 20—05 American Softwood Lumber Standard R404.2.1, R502.1.1, R602.1.1, R802.1.1

DOTn Department of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
Title Referenced
in code
section number
49 CFR, Parts 192.281(e)
& 192.283 (b) (2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards G2415.6.1

FEMA Federal Emergency Management Agency
500 C Street, SW
Washington, DC 20472
Standard
reference
number
Title Referenced
in code
section number
FEMA TB-2—08 Flood Damage-resistant Materials Requirements R322.1.8
FEMA TB-11—01 Crawlspace Construction for Buildings Located in Special Flood Hazard Area R408.7

FM Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson, RI 02919
Standard
reference
number
Title Referenced
in code
section number
4450—(1989) Approval Standard for Class 1 Insulated Steel Deck Roofs—
with Supplements through July 1992
R906.1
4470—(1992) Approval Standard for Class 1 Roof Covers R316.8.1.2
4471—(2010) Approval Standards for Class 1 Panel Roofs R316.8.1.2
4880—(2010) American National Standard for Evaluating Insulated Wall or
Wall and Roof/Ceiling Assemblies, Plastic Interior Finish Materials,
Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,
Interior and Exterior Finish Systems
R316.6

GA Gypsum Association
6525 Belcrest Road, Suite 480
Hyattsville, MD 20782
Standard
reference
number
Title Referenced
in code
section number
GA-253—12 Application of Gypsum Sheathing Table R602.3(1)

HPVA Hardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190-5350
Standard
reference
number
Title Referenced
in code
section number
ANSI/HP-1—2013 Standard for Hardwood and Decorative Plywood R702.5

ICC International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
ICC 400—12 Standard on the Design and Construction of Log Structures R301.1.1, 502.1.4, R602.1.4, R703.1, R802.1.3
ICC 500—14 ICC/NSSA Standard on the Design and Construction of Storm Shelters R323.1
IEBC—15 International Existing Building Code® R110.2

ISO International Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
Title Referenced
in code
section number
8336—2009 Fibre-cement Flat Sheets-product Specification
and Test Methods
Table R503.2.1.1(1), Table R503.2.1.1(2), Table R602.3(2),
Table R702.4.2, R703.10.1, R703.10.2
15874—2002 Polypropylene Plastic Piping Systems for Hot and Cold Water Installations Table M2101.1

MSS Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
Standard
reference
number
Title Referenced
in code
section number
SP-58—09 Pipe Hangers and Supports—Materials, Design, Manufacture, Selection,
Application and Installation
M1309.4, G2419.2

NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
AH 116—09 Fibrous Glass Duct Construction Standards, Fifth Edition M1601.1.1

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
Title Referenced
in code
section number
13D—13 Standard for the Installation of Sprinkler Systems in One- and Two-family
Dwellings and Manufactured Homes
R302.2, R302.2.1.3, R302.2.5, R302.2.6.2, R302.3,
R302.5.1.1, Table R302.6, R302.7, R302.13
31—11 Standard for the Installation of Oil-burning Equipment M1701.1, M1801.3.1, M1805.3
37-98 Standard for Installation and Use of Stationary Combustion Engines and Gas Turbines G2439.1
54-99 National Fuel Gas Code G2418.4.1
58—14 Liquefied Petroleum Gas Code G2413.2, G2415.6.2, G2422.3
72—13 National Fire Alarm and Signaling Code R314.1, R314.7.1
211—13 Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances R1002.5, G2428.5.5.1
259—13 Standard for Test Method for Potential Heat of Building Materials R316.5.7, R316.5.8
275—13 Standard Method of Fire Tests for the Evaluation of Thermal Barriers R316.4
285-12 Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior
Nonload-bearing Wall Assemblies Containing Combustible Components
R316.8.1.2
286—15 Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
R302.9.4, R316.6
720—15 Standard for the Installation of Carbon Monoxide (CO) Detectors
and Warning Equipment
R315.6.1, R315.6.2
853—15 Standard on the Installation of Stationary Fuel Cell Power Systems M1905.1

NSF NSF International
789 N. Dixboro
Ann Arbor, MI 48105
Standard
reference
number
Title Referenced
in code
section number
358-1—2011 Polyethylene Pipe and Fittings for Water-based Ground Source
"Geothermal" Heat Pump Systems
M2105.4, M2105.5
358-2—2012 Polypropylene Pipe and Fittings for Water-based Ground Source
"Geothermal" Heat Pump Systems
M2105.5

PCA Portland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
Standard
reference
number
Title Referenced
in code
section number
100—12 Prescriptive Design of Exterior Concrete Walls for One- and
Two-family Dwellings (Pub. No. EB241)
R301.2.2.2.4, R301.2.2.3.4, R404.1.3,
R404.1.3.2.1, R404.1.3.2.2, R404.1.3.4, R404.1.4.2,
R608.1, R608.2, R608.5.1, R608.9.2, R608.9.3

SBCA Structural Building Components Association
6300 Enterprise Lane
Madison, WI 53719
Standard
reference
number
Title Referenced
in code
section number
BCSI—2013 Building Component Safety Information Guide to Good Practice for Handling,
Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses
502.11.2, 802.10.3
CFS-BCSI—2008 Cold-formed Steel Building Component Safety Information (CFSBCSI)
Guide to Good Practice for Handling, Installing & Bracing of Cold-formed Steel Trusses
505.1.3, 804.3.6
FS100—12 Standard Requirements for Wind Pressure Resistance of Foam Plastic
Insulating Sheathing Used in Exterior Wall Covering Assemblies
R316.7

SMACNA Sheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
Standard
reference
number
Title Referenced
in code
section number
SMACNA—10 Fibrous Glass Duct Construction Standards (2003) M1601.1.1, M1601.4.1
SMACNA—15 HVAC Duct Construction Standards, Metal and Flexible (2005) M1601.4.1

SRCC Solar Rating & Certification Corporation
400 High Point Drive, Suite 400
Cocoa, FL 32926
Standard
reference
number
Title Referenced
in code
section number
SRCC 100—13 Standard 100 for Solar Collectors M2301.3.1
SRCC 300—13 Standard 300 for Solar Water Heating Systems M2301.4, M2301.2.6, M2301.2.8

TMS The Masonry Society
105 South Sunset Street, Suite Q
Longmont, CO 80501
Standard
reference
number
Title Referenced
in code
section number
402—2013 Building Code Requirements for Masonry Structures R404.1.2, R606.1, R606.1.1,
R606.2.3.2, R606.12.1, R606.12.2.3.1,
R606.12.3.1, Table R703.4, 703.12
403—2013 Direct Design Handbook for Masonry Structures R606.1, R606.1.1, R606.12.1,
R606.12.3.1
602—2013 Specification for Masonry Structures R404.1.2, R606.2.9, R606.2.12, R606.12.3.1, R703.12

TPI Truss Plate Institute
218 N. Lee Street, Suite 312
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
TPI 1—2014 National Design Standard for Metal-plate-connected
Wood Truss Construction
R502.11.1, R802.10.2

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
Title Referenced
in code
section number
17—2008 Vent or Chimney Connector Dampers for Oil-fired Appliances
with revisions through January 2010
M1802.2.2
55A—04 Materials for Built-up Roof Coverings R905.9.2
58—96 Standard for Underground Tanks for Flammable and Combustible Liquids with Revisions through July 1998 M2201.1
80—2007 Steel Tanks for Oil-burner Fuel—with revisions August 2009 M2201.1
103—2010 Factory-built Chimneys for Residential Type and Building Heating
Appliances—with revisions through July 2012
R202, R1005.3, G2431.1
127—2011 Factory-built Fireplaces R1001.11, R1004.1,
R1004.4, R1004.5, R1005.4, G2446.7
174—04 Household Electric Storage Tank Water Heaters—
with revisions through September 2012
M2005.1
180—2012 Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids M2201.5
181—05 Factory-made Air Ducts and Air Connectors—with revisions through May 2003 M1601.1.1, M1601.4.1
181A—2013 Closure Systems for Use with Rigid Air Ducts and Air Connectors—
with revisions through December 1998
M1601.2, M1601.4.1
181B—2013 Closure Systems for Use with Flexible Air Ducts and Air Connectors—
with revisions through August 2003
M1601.4.1
217—06 Single- and Multiple-station Smoke Alarms—with revisions through April 2012 R314.1.1, R315.1.1
263—2011 Standards for Fire Test of Building
Construction and Materials
Table 302.1, R302.2, R302.3, R302.4.1, R302.11.1, R606.2.2
268—2009 Smoke Detectors for Fire Alarm Systems R314.7.1, R314.7.4, R315.6.4
325—02 Door, Drapery, Gate, Louver and Window Operations and Systems—
with revisions through June 2013
R309.4
343—2008 Pumps for Oil-burning Appliances—with revisions through June 2013 M2204.1
378—06 Draft Equipment—with revisions through January 2010 M1804.2.6
441—10 Gas Vents G2427.1
508—99 Industrial Control Equipment—with revisions through March 2013 M1411.3.1
536—97 Flexible Metallic Hose—with revisions through June 2003 M2202.3
641—2010 Type L, Low-temperature Venting Systems
with revisions through May 2013
R202, R1003.11.5, M1804.2.4, G2427.1
651—2011 Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings—
with revisions through March 2012
G2415.6.3
705—04 Standard for Power Ventilators—with revisions through March 2012 M1502.4.4
723—08 Standard for Test for Surface Burning Characteristics of
Building Materials—with revisions through September 2010
R202, R302.9.3, R302.9.4, R302.10.1,
R302.10.2, R316.3, R316.5.9, R316.5.11,
R507.3.2, R802.1.5, M1601.3
726—95 Oil-fired Boiler Assemblies—with revisions through April 2011 M2001.1.1, M2006.1
727—06 Oil-fired Central Furnaces—with revisions through April 2010 M1402.1
729—03 Oil-fired Floor Furnaces—with revisions through August 2012 M1408.1
730—03 Oil-fired Wall Furnaces—with revisions through August 2012 M1409.1
732—95 Oil-fired Storage Tank Water Heaters—with revisions through April 2010 M2005.1
737—2011 Fireplaces Stoves M1414.1, M1901.2
790—04 Standard Test Methods for Fire Tests of Roof Coverings
with revisions through October 2008
R302.2.2, R316.8.1.2, R902.1
795—2011 Commercial-industrial Gas Heating Equipment
with revisions through September 2012
G2443.1
834—04 Heating, Water Supply and Power Boilers—Electric—with revisions
through January 2013
M2001.1.1
842—07 Valves for Flammable Fluids—with revisions through October 2012 M2204.2
858—05 Household Electric Ranges—with revisions through April 2012 M1901.2
875—09 Electric Dry-bath Heaters with revisions through November 2011 M1902.2
896—93 Oil-burning Stoves—with revisions through August 2012 M1410.1
923—2013 Microwave Cooking Appliances M1504.1
959—2010 Medium Heat Appliance Factory-built Chimneys R1005.6
1026—2012 Electric Household Cooking and Food Serving Appliances M1901.2
1040—96 Fire Test of Insulated Wall Construction—with revisions through October 2012 R316.6
1042—2009 Electric Baseboard Heating Equipment—with revisions through June 2013 M1405.1
1256—02 Fire Test of Roof Deck Construction—with revisions through January 2007 R906.1
1261—01 Electric Water Heaters for Pools and Tubs—with revisions through July 2012 M2006.1
1479—03 Fire Tests of Through-Penetration Firestops—with revisions through October 2012 R302.4.1.2
1482—2011 Solid-Fuel-type Room Heaters R1002.2, R1002.5, M1410.1
1618—09 Wall Protectors, Floor Protectors, and Hearth Extensions—
with revisions through May 2013
R1004.2, M1410.2
1693—2010 Electric Radiant Heating Panels and Heating Panel Sets—
with revisions through October 2011
M1406.1
1715—97 Fire Test of Interior Finish Material—with revisions through January 2013 R316.6
1738—2010 Venting Systems for Gas-burning Appliances, Categories II, III and IV—
with revisions Through May 2011
G2427.1
1777—07 Chimney Liners—with revisions through July 2009 R1003.11.1, R1003.18,
G2426.12, G2426.15.4, M1801.3.4
1995—2011 Heating and Cooling Equipment M1402.1, M1403.1,
M1407.1, M1412.1, M1413.1
1996—2009 Electric Duct Heaters—with revisions through November 2011 M1402.1, M1407.1
2034—08 Standard for Single- and Multiple-station Carbon Monoxide Alarms—
with revisions through February 2009
R314.1.1, R315.1.1
2075—2013 Standard for Gas and Vapor Detectors and Sensors R314.7.4, R315.6.1, R315.6.4
2523—09 Standard for Solid Fuel-fired Hydronic Heating Appliances, Water Heaters and Boilers
with revisions through February 2013
M2005.1, M2001.1.1
UL/CSA/ANCE
60335-2-40—2012
Standard for Household and Similar Electrical Appliances,
Part 2: Particular Requirements for Motor-compressors
M1403.1, M1412.1, M1413.1

ULC ULC
7 Underwriters Road
Toronto, Ontario, Canada M1R 3B4
Standard
reference
number
Title Referenced
in code
section number
CAN/ULC S 102.2—2010 Standard Methods for Test for Surface Burning Characteristics
of Building Materials and Assemblies
R302.10.1, R302.10.2

WDMA Window & Door Manufacturers Association
2025 M Street, NW Suite 800
Washington, DC 20036-3309
Standard
reference
number
Title Referenced
in code
section number
AAMA/WDMA/CSA
101/I.S2/A440—11
North American Fenestration Standard/
Specifications for Windows, Doors and Skylights
R308.6.9, R609.3, Chapter 11
I.S. 11—13 Industry Standard Analytical Method for Design Pressure (DP)
Ratings of Fenestration Products
R308.6.9.1, R609.3.1