Chapter 6 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 107.


AAMA American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg, IL 60173-4268
Standard
reference
number
Title Referenced in code section number
AAMA/WDMA/CSA 101/I.S.2/A c440—11 Specifications for Windows, Doors and Unit Skylights 502.4.1



AHRI Air Conditioning, Heating, and Refrigeration Institute
4100 North Fairfax Drive
Suite 200
Arlington, VA 22203
Standard
reference
number
Title Referenced in code section number
210/240—08 Unitary Air-Conditioning and Air-Source Heat Pump Equipment Table 503.2.3(1), Table 503.2.3(2)
310/380—04 Standard for Packaged Terminal Air-conditioners and Heat Pumps Table 503.2.3(3)
340/360—2007 Commercial and Industrial Unitary Air-conditioning and Heat Pump Equipment Table 503.2.3(1), Table 503.2.3(2)
365—09 Commercial and Industrial Unitary Air-conditioning Condensing Units Table 503.2.3(3)
390—03 Performance Rating of Single package Vertical Air Conditioners and Heat Pumps 503.2.8
400—01 Liquid to Liquid Heat Exchangers with Addendum 2 Table 503.2.3(9)
440—08 Room Fan-coil 503.2.8
460—05 Performance Rating Remote Mechanical Draft Air-cooled Refrigerant Condensers Table 503.2.3(8)
550/590—03 Water Chilling Packages Using the Vapor Compression Cycle—with Addenda Table 503.2.3(7)
560—00 Absorption Water Chilling and Water Heating Packages Table 503.2.3(7)
840—1998 Unit Ventilators 503.2.8
13256-1 (2005) Water-source Heat Pumps—Testing and Rating for Performance—Part 1: Water-to-air and Brine-to-air Heat Pumps Table 503.2.3(2)
13256-2 (1998) Water-source Heat Pumps—Testing and Rating for Performance—Part 2: Water-to-air and Brine-to-air Heat Pumps Table 503.2.3(2)
1160—2008 Performance Rating of Heat Pump Pool Heaters Table 504.2



AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004-1806
Standard
reference
number
Title Referenced in code section number
500D—07 Laboratory Methods for Testing Dampers for Rating 502.4.5



ANSI American National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced in code section number
Z21.10.3/CSA 4.3—04 Gas Water Heaters, Volume III - Storage Water Heaters with Input Ratings Above 75,000 Btu per Hour, Circulating Tank and Instantaneous Table 504.2
Z21.13—04 Gas-fired Low Pressure Steam and Hot Water Boilers Table 503.2.3(5)
Z21.47/CSA 2.3—06 Gas-fired Central Furnaces Table 503.2.3(4)
Z83.8/CSA 2.6—09 Gas Unit Heaters and Gas-Fired Duct Furnaces—with Addendum Z83.8a-2003 Table 503.2.3(4)



ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
Standard
reference
number
Title Referenced in code section number
140—2007 Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs 506.6.1
146—1998 Testing and Rating Pool Heaters Table 504.2
ANSI/ASHRAE/ACCA Standard 183—2007 Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings 503.2.1
90.1—2007 Energy Standard for Buildings Except Low-rise Residential Buildings (ANSI/ASHRAE/IESNA 90.1-2010) 501.1, 501.2, 502.1.1, Table 502.2(2)
ASHRAE—2005 ASHRAE Handbook of Fundamentals 402.1.4, Table 405.5.2(1)
ASHRAE—2004 ASHRAE HVAC Systems and Equipment Handbook-2004 503.2.1
ASHRAE—2009 ASHRAE Handbook of Fundamentals 303.1.3



ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2859
Standard
reference
number
Title Referenced in code section number
E 283—04 Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen 502.4.2, 502.4.8



CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced in code section number
AAMA/WDMA/CSA
101/I.S.2/A440—11
Specifications for Windows, Doors and Unit Skylights 502.4.1



DOE U.S. Department of Energy
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced in code section number
10 CFR Part 430, Subpart B, Appendix E (1998) Uniform Test Method for Measuring the Energy Consumption of Water Heaters Table 504.2
10 CFR Part 430, Subpart B, Appendix N (1998) Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers Table 503.2.3(4), Table 503.2.3(5)
10 CFR Part 431, Subpart E 2004 Test Procedures and Efficiency Standards for Commercial Packaged Boilers Table 503.2.3(6)
DOE/EIA—0376 (Current Edition) State Energy Prices and Expenditure Report 506.2



IESNA Illuminating Engineering Society of North America
120 Wall Street, 17th Floor
New York, NY 10005-4001
Standard
reference
number
Title Referenced in code section number
90.1-2010 Energy Standard for Buildings Except Low-rise Residential Buildings 501.1, 501.2, 502.1.1, Table 502.2(2)



ISO International Organization for Standardization
1, rue de Varembe, Case postale 56, CH-1211
Geneva, Switzerland
Standard
reference
number
Title Referenced in code section number
SO/AHRI/ASHRAE
13256-1 (2005)
Water-source Heat Pumps—Testing and Rating for Performance— Part 1: Water-to-air and Brine-to-air Heat Pumps 503.2.3(2)
ISO/AHRI/ASHRAE
13256-2 (1998)
Water-Source Heat Pumps—Testing and Rating for Performance— Part 2: Water-to-water and Brine-to-water Heat Pumps 503.2.3(2)
NFRC National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt, MD 20770
Standard
reference
number
Title Referenced in code section number
100—09 Procedure for Determining Fenestration Product U-factors—Second Edition 303.1.3
200—09 Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence—Second Edition 303.1.3
400—09 Procedure for Determining Fenestration Product Air Leakage—Second Edition 502.4.1



SMACNA Sheet Metal and Air Conditioning Contractors National Association, Inc.
4021 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
Title Referenced in code section number
SMACNA—85 HVAC Air Duct Leakage Test Manual 503.2.7.1.3



UL Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced in code section number
727—06 Oil-fired Central Furnaces Table 503.2.3(4)
731—95 Oil-fired Unit Heaters—with Revisions through February 2006 Table 503.2.3(4)



US—FTC United States - Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
Title Referenced in code section number
CFR Title 16 R-value Rule 303.1.4



WDMA Window and Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
Title Referenced in code section number
AAMA/WDMA/CSA 101/I.S.2/A440— 11 Specifications for Windows, Doors and Unit Skylights 502.4