Appendix X Swimming Pools, Spas, and Hot Tubs

AMENDMENT
This section has been amended at the state or city level.
The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance or order.

Section X101 Swimming Pools, Spas and Hot Tubs

AMENDMENT
This section has been amended at the state or city level.

X101.1 General

AMENDMENT
This section has been amended at the state or city level.
The provisions of this appendix shall control the design and construction of swimming pools, spas and hot tubs installed in or on the lot of a one- or two-family dwelling.

X101.2 Pools in Flood Hazard Areas

AMENDMENT
This section has been amended at the state or city level.
Pools that are located in flood hazard areas established by Table R301.2(1), including above-ground pools, on-ground pools, and in-ground pools that involve placement of fill, shall comply with Sections X101.2.1 or X101.2.2.
Exception: Pools located in riverine flood hazard areas which are outside of designated floodways.

X101.2.1 Pools Located in Designated Floodways

AMENDMENT
This section has been amended at the state or city level.
Where pools are located in designated floodways, documentation shall be submitted to the building official, which demonstrates that the construction of the pool will not increase the design flood elevation at any point within the jurisdiction.

X101.2.2 Pools Located Where Floodways Have Not Been Designated

AMENDMENT
This section has been amended at the state or city level.
Where pools are located where design flood elevations are specified but floodways which have not been designated, the applicant shall provide a floodway analysis that demonstrates that the proposed pool will not increase the design flood elevation more than 1 foot (305 mm) at any point within the jurisdiction.

Section X102 Definitions

AMENDMENT
This section has been amended at the state or city level.

X102.1 General

AMENDMENT
This section has been amended at the state or city level.
For the purposes of these requirements, the terms used shall be defined as follows and as set forth in Chapter 2.

ABOVE-GROUND/ON-GROUND POOL. See "Swimming pool."

BARRIER. A fence, wall, building wall or combination thereof which completely surrounds the swimming pool and obstructs access to the swimming pool.

HOT TUB. See "Swimming pool."

IN-GROUND POOL. See "Swimming pool."

RESIDENTIAL. That which is situated on the premises of a detached one- or two-family dwelling or a one-family townhouse not more than three stories in height.

SPA, NONPORTABLE. See "Swimming pool."

SPA, PORTABLE. A nonpermanent structure intended for recreational bathing, in which all controls, water-heating and water-circulating equipment are an integral part of the product.

SWIMMING POOL. Any structure intended for swimming or recreational bathing that contains water over 24 inches (610 mm) deep. This includes in-ground, above-ground, and on-ground swimming pools, hot tubs and spas.

SWIMMING POOL, INDOOR. A swimming pool which is totally contained within a structure and surrounded on all four sides by the walls of the enclosing structure.

SWIMMING POOL, OUTDOOR. Any swimming pool which is not an indoor pool.

Section X103 Swimming Pools

AMENDMENT
This section has been amended at the state or city level.

X103.1 In-Ground Pools

AMENDMENT
This section has been amended at the state or city level.
In-ground pools shall be designed and constructed in conformance with ANSI/NSPI-5 as listed in Section X108.

X103.2 Above-Ground and On-Ground Pools

AMENDMENT
This section has been amended at the state or city level.
Above-ground and on-ground pools shall be designed and constructed in conformance with ANSI/NSPI-4 as listed in Section X108.

X103.3 Pools in Flood Hazard Areas

AMENDMENT
This section has been amended at the state or city level.
In flood hazard areas established by Table R301.2(1), pools in costal high hazard areas shall be designed and constructed in conformance with ASCE 24.

Section X104 Spas and Hot Tubs

AMENDMENT
This section has been amended at the state or city level.

X104.1 Permanently Installed Spas and Hot Tubs

AMENDMENT
This section has been amended at the state or city level.
Permanently installed spas and hot tubs shall be designed and constructed in conformance with ANSI/NSPI-3 as listed in Section X108.

X104.2 Portable Spas and Hot Tubs

AMENDMENT
This section has been amended at the state or city level.
Portable spas and hot tubs shall be designed and constructed in conformance with ANSI/NSPI-6 as listed in Section X108.

Section X105 Barrier Requirements

AMENDMENT
This section has been amended at the state or city level.

X105.1 Application

AMENDMENT
This section has been amended at the state or city level.
The provisions of this chapter shall control the design of barriers for residential swimming pools, spas and hot tubs. These design controls are intended to provide protection against potential drownings and near drownings by restricting access to swimming pools, spas and hot tubs.

X105.2 Outdoor Swimming Pool

AMENDMENT
This section has been amended at the state or city level.
An outdoor swimming pool, including an in-ground, above-ground, or on-ground pool, hot tub or spa shall comply with one of the following:
  1. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade, such as an above-ground pool, the barrier may be at ground level or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm).
  2. Openings in the barrier shall not allow passage of a 4-inch-diameter sphere.
  3. Solid barriers which do not have openings, such as a masonry or stone wall, shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints.
  4. Where the barrier is composed of horizontal and vertical fence members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical fence members shall not exceed 13/4 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 13/4 inches (44 mm) in width.
  5. Where the barrier is composed of horizontal and vertical fence members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between the vertical fence members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 13/4 inches (44 mm) in width.
  6. Maximum mesh size for chain link fences shall be 21/4 inches (57 mm) square unless the fence has slats fastened at the top or bottom which reduce the openings to not more than 13/4 inches (44 mm).
  7. Where the barrier is composed of diagonal members, such as lattice fence, the maximum opening formed by the diagonal members shall not be more than 13/4 inches (44 mm).
  8. Access gates shall comply with the requirements of Section X105.2 Items A through G, and shall be equipped to accommodate a locking device. Pedestrian access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from the bottom of the gate, the release mechanism and openings shall comply with the following:
    1. The release mechanism shall be located on the pool side of the gate at least 3 inches (76 mm) below the top of the gate; and
    2. The gate and barrier shall have no opening larger than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism.
  9. Where a wall of a dwelling serves as part of the barrier, one of the following conditions shall be met:
    1. The pool shall be equipped with a powered safety cover in compliance with ASTM F 1346; or
    2. Doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible and visual warning when the door and/or its screen, if present, are opened. The alarms shall be listed and labeled in accordance with UL 2017. The deactivation switch(es) shall be located at least 54 inches (1372 mm) above the threshold of the door; or
    3. Other means of protection, such as self-closing doors with self-latching devices, which are approved by the governing body, shall be acceptable as long as the degree of protection afforded is not less than the protection afforded by Item G.i or G.ii as described above.
  10. Where an above-ground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and the means of access is a ladder or steps;
    1. The ladder or steps shall be capable of being secured, locked or removed to prevent access; or
    2. The ladder or steps shall be surrounded by a barrier which meets the requirements of Section X105.2, Items A through I. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a 4-inch (102 mm) sphere.

X105.3 Indoor Swimming Pool

AMENDMENT
This section has been amended at the state or city level.
Wall surrounding an indoor swimming pool shall comply with Section X105.2, Item I.

X105.4 Prohibited Locations

AMENDMENT
This section has been amended at the state or city level.
Barriers shall be located to prohibit permanent structures, equipment or similar objects from being used to climb over the pool barrier.

X105.5 Barrier Exceptions

AMENDMENT
This section has been amended at the state or city level.
Spas or hot tubs with a safety cover which complies with ASTM F 1345, as listed in Section X107, shall be exempt from the barrier provisions of this appendix.

Section X106 Entrapment Protection for Swimming Pool and Spa Suction Outlets

AMENDMENT
This section has been amended at the state or city level.

X106.1 General

AMENDMENT
This section has been amended at the state or city level.
Suction outlets shall be designed and installed in accordance with ANSI/APSP-7.

Section X107 Abbreviations

AMENDMENT
This section has been amended at the state or city level.
ANSI — American National Standards Institute, 11 West 42nd Street, New York, NY 10036

APSP — Association of Pool and Spa Professionals

NSPI — National Spa and Pool Institute, 2111 Eisenhower Ave, Alexandria, VA 22314

ASCE — American Society of Civil Engineers, 1801 Alexander Bell Drive, Reston, VA 98411-0700

ASTM — ASTM International, 1000 Barr Harbor Drive, West Conshohocken, PA 19428

UL — Underwriters Laboratories, Inc., 333 Pfingsten Rd., Northbrook, IL 60062-2096

Section X108 Standards

AMENDMENT
This section has been amended at the state or city level.
ANSI/NSPI-3-99 Standard for Permanently Installed Residential Spas, Section X104.1

ANSI/NSPI-4-99 Standard for Above-ground/On-ground Residential Swimming Pools, Section X103.2

ANSI/NSPI-5-2003 Standard for Residential In-ground Swimming pools, Section X103.1

ANSI/NSPI-6-99 Standard for Residential Portable Spas, Section X104.2

ANSI/APSP-7-06 Standard for Suction Entrapment avoidance in Swimming Pools, Wading Pools, Spas, Hot Tubs and Catch Basins, Section X106.1

ASCE/SEI-24-05 Flood Resistant Design and Construction, Section X103.3

ASTM F-1346-91 (2003) Performance Specification for Safety Covers and Labeling Requirements for All Covers for Swimming Pools, Spas and Hot Tubs Sections X105.2, X105.5

UL 2017-2000 Standard for General-purpose Signaling Devices and Systems — with Revisions through June 2004, Section X105.1