Appendix W Energy Efficiency

AMENDMENT
This section has been amended at the state or city level.
The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance or order.

Section W101 General

AMENDMENT
This section has been amended at the state or city level.
This section has been added to specify the provisions of this appendix shall apply exclusively to the requirements for a Certificate listing energy efficiency components included in a residential dwelling unit.

W101.1 Certificate

AMENDMENT
This section has been amended at the state or city level.
A permanent certificate shall be completed by the builder or registered design professional and posted on a wall in the space where the furnace is located, a utility room or an approved location inside the building. Where located on an electrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect label, or other required labels. The certificate shall list the predominate R-values of insulation installed in or on the ceiling/roof, walls, foundation (slab, basement wall, crawl space wall/or floor) and ducts outside conditioned spaces; U-factors for fenestration and the solar heat gain coefficient (SHGC) of fenestration, and the results from any required duct system and building envelope air leakage testing done on the building. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the types and efficiencies of heating, cooling and service water heating equipment. Where a gas-fired unvented room heater, electric furnace, or baseboard electric heater is installed in the residence, the certificate shall list "gas-fired unvented room heater," "electric furnace" or "baseboard electric heater," as appropriate. An efficiency shall not be listed for gas-fired unvented room heaters, electric furnaces or electric baseboard heaters.