Heads up: There are no amended sections in this chapter.

Chapter 8 Referenced Standards (IFGC/IFGS)

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ANSI American National Standards Institute
25 West 43rd Street
Fourth Floor
New York, NY 10036
 
Standard
reference
number
Title Referenced
in code
section number
ANSI A13.1—2007 Scheme for the Identification of Piping Systems 704.1.2.2
ANSI FC 1—2012 Stationery Fuel Cell Power Systems 633.1
LC 1/CSA 6.26—13 Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) 403.5.4
ANSI LC-4/CSA 6.32—12 Press-connect Metallic Fittings for Use In Fuel Gas Distribution Systems 403.10.2
Z21.1—2010 Household Cooking Gas Appliances 623.1
Z21.5.1/CSA 7.1—2014 Gas Clothes Dryers—Volume I—Type 1 Clothes Dryers 613.1
Z21.5.2/CSA 7.2—2014 Gas Clothes Dryers—Volume II—Type 2 Clothes Dryers 613.1, 614.3
Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners 619.1
Z21.10.1/CSA 4.1—2012 Gas Water Heaters—Volume I—Storage, Water Heaters with Input Ratings
of 75,000 Btu per Hour or Less
624.1
Z21.10.3/CSA 4.3—2011 Gas Water Heaters—Volume III—Storage, Water Heaters with Input Ratings
Above 75,000 Btu per hour, Circulating and Instantaneous
624.1
Z21.11.2—2011 Gas-fired Room Heaters-Volume II-Unvented Room Heaters 621.1
Z21.13/CSA 4.9—2011 Gas-fired Low-pressure Steam and Hot Water Boilers 631.1
Z21.15/CGA 9.1—09 Manually Operated Gas Valves for Appliances, Appliance Connector Valves and
Hose End Valves
Table 409.1.1
Z21.19/CSA 1.4—
02(R2007)
Refrigerators Using Gas (R1999) Fuel 625.1
Z21.24/CGA 6.10—06 Connectors for Gas Appliances 411.1, 411.3
Z21.40.1/CGA 2.91—96
(R2011)
Gas-Fired Heat Activated Air Conditioning and Heat Pump Appliances 627.1
Z21.40.2/CGA 2.92—96
(R2011)
Gas-Fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion) 627.1
Z21.42—2014 Gas-Fired Illuminating Appliances 628.1
Z21.47/CSA 2.3—2012 Gas-Fired Central Furnaces 618.1
Z21.50/CSA 2.22—2012 Vented Gas Fireplaces 604.1
Z21.54—09 Gas Hose Connectors for Portable Outdoor Gas Fired Appliances 411.1
Z21.56/CSA 4.7—2013 Gas-Fired Pool Heaters 617.1
Z21.58/CSA 1.6—2013 Outdoor Cooking Gas Appliances 623.1
Z21.60/CSA 2.26—2012 Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces 602.1
Z21.61—83 (R2004) Gas-fired Toilets 626.1
Z21.69/CSA 6.16—09 Connectors for Movable Gas Appliances 411.1.1, 411.1.4
Z21.75/CSA 6.27—07 Connectors for Outdoor Gas Appliances and Manufactured Homes 411.1, 411.2
Z21.80/CSA 6.22—11 Line Pressure Regulators 410.1
Z21.84—2012 Manually-lighted, Natural Gas Decorative Gas Appliances for Installation in
Solid Fuel Burning Fireplaces
602.1, 602.2
Z21.86/CSA 2.32—08 Vented Gas-fired Space Heating Appliances 608.1, 609.1, 622.1
Z21.88/CSA 2.33—2014 Vented Gas Fireplace Heaters 605.1
Z21.91—07 Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters 621.7.1
Z21.97—2012 Outdoor Decorative Appliances 636.1
Z83.4/CSA 3.7—2012 Nonrecirculating Direct-gas-fired Industrial Air Heaters 611.1
Z83.8/CSA 2.6—09 Gas Unit Heater, Gas Packaged Heater, Gas Utility Heaters and Gas-fired Duct Furnaces 610.1, 620.1
Z83.11/CSA 1.8—2013 Gas Food Service Equipment 623.1
Z83.18—2012 Recirculating Direct Gas-fired Industrial Air Heaters 612.1
Z83.19—01(R2009) Gas-fired High-intensity Infrared Heaters 630.1
Z83.20—08 Gas-fired Low-intensity Infrared Heaters 630.1

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—83
(Reaffirmed 2006)
Pipe Threads, General Purpose (inch) 403.9
B16.1—2010 Cast-iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250 403.12.1
B16.5—R2009 Pipe Flanges and Flanged Fittings: NPS 1/2 through NFPS 24 Metric/Inch Standard 403.12.2
B16.24—2011 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Classes 150, 300, 600, 900, 1500 and 2500 403.12.3
B16.42—2011 Ductile Iron Pipe Flanges and Flanged Fittings, Classes 150 and 300 403.12.4
B16.47—2011 Large Diameter Steel Flanges: NPS 26 through NPS 60 Metric/Inch Standard 403.12.2
B16.33—2012 Manually Operated Metallic Gas Valves for Use in Gas Piping Systems
up to 125 psig (Sizes 1/2 through 2)
Table 409.1.1
B16.44—2002
(Reaffirmed 2007)
Manually Operated Metallic Gas Valves for Use in Aboveground Piping Systems
Up to 5 psi
Table 409.1.1
B31.3—2012 Process Piping 704.1.2.4
B31.12—2008 Hydrogen Piping and Pipelines 704.1.2, 704.1.2.4, 705.2, 705.3
B36.10M—2004 Welded and Seamless Wrought-steel Pipe 403.4.2
BPVC—2010/2011 addenda ASME Boiler & Pressure Vessel Code (2007 Edition) 631.1, 703.2.2, 703.3.3, 703.3.4
CSD-1—2011 Controls and Safety Devices for Automatically Fired Boilers 631.1

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
 
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—12 Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless 403.4.2
A 106/A 106M—11 Specification for Seamless Carbon Steel Pipe for High-temperature Service 403.4.2
A 254—97 (2007) Specification for Copper Brazed Steel Tubing 403.5.1
B 88—09 Specification for Seamless Copper Water Tube . 403.5.2
B 210—12 Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes 403.5.3
B 241/B 241M—12E1 Specification for Aluminum and Aluminum-alloy, Seamless Pipe
and Seamless Extruded Tube
403.4.4, 403.5.3
B280—08 Standard Specification for Seamless Copper Tube for Air-Conditioning and
Refrigeration Field Service
403.5.2
C 315—07(2011) Specification for Clay Flue Liners and Chimney Pots 501.12
D 2513—2013E1 Specification for Polyethylene (PE) Gas Pressure Pipe, Tubing and Fittings 403.6, 403.6.1, 403.11, 404.17.2
E136—2012 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 202
F 1973—08 Standard Specification for Factory Assembled Anodeless Risers and
Transition Fittings in Polyethylene (PE) and Polyamide 11 (PA11)
and Polyamide 12 (PA12) Fuel Gas Distribution Systems
404.17.2

CGA Compressed Gas Association
14501 George Carter Way, Suite 103
Chantilly, VA 20151-2923
 
Standard
reference
number
Title Referenced
in code
section number
S-1.1—(2011) Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases 703.3
S-1.2—(2005) Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases 703.3
S-1.3—(2008) Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases 703.3


CSA CSA America Inc.
8501 E. Pleasant Valley Rd.
Cleveland, OH USA 44131-5575
 
Standard
reference
number
Title Referenced
in code
section number
ANSI CSA America
FC1—2012
Stationary Fuel Cell Power Systems 633.1
CSA 8—93 Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces—with
Revisions through January 1999
603.1

DOTn Department of Transportation
400 Seventh St. SW.
Washington, DC 20590
 
Standard
reference
number
Title Referenced
in code
section number
49 CFR, Parts 192.281(e)
& 192.283 (b)—(2009)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards 403.6.1
49 CFR Parts 100—180 Hazardous Materials Regulations 703.2.2, 703.3.3, 703.3.4

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
IBC®—15 International Building Code®
as adopted and modified by the
State of Oklahoma through the OUBCC
102.2.1, 201.3, 301.10, 301.11,
301.12, 301.14, 302.1, 302.2,
305.6, 306.5.1, 06.6, 401.1.1, 412.6,
413.3, 413.3.1, 501.1, 501.3,
501.12, 501.15.4, 501.15.4.1, 609.3,
614.10, 633.1, 635.1, 706.2
IECC®06 International Energy Conservation Code® 301.2
IFC®—15 International Fire Code®
as adopted and modified by the
State of Oklahoma through the OUBCC
201.3, 401.2, 412.1, 412.6,
412.7, 412.7.3, 412.8, 413.1,
413.3, 413.3.1, 413.5, 413.9.2.5,
633.1, 701.1, 701.2, 703.2, 703.2.2,
703.3.8, 703.4, 703.5, 704.1.2,
704.3, 704.4, 706.2, 706.3,
707.1, 707.2, 708.1
IMC®—15 International Mechanical Code®
as adopted and modified by the
State of Oklahoma through the OUBCC
101.2.5, 201.3, 301.1.1, 301.13,
304.11, 307.1, 307.5, 501.1, 614.2, 614.10, 618.4,
621.1, 624.1, 631.2, 632.1, 703.1.2
IPC®—15 International Plumbing Code®
as adopted and modified by the
State of Oklahoma through the OUBCC
201.3, 301.6, 307.3, 624.1.1, 624.2
IRC®—15 International Residential Code®
as adopted and modified by the
State of Oklahoma through the OUBCC
101.2, 703.2.1

MSS Manufacturers Standardization Society of
the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
 
Standard
reference
number
Title Referenced
in code
section number
SP 58—2009 Pipe Hangers and Supports-Materials, Design and Manufacture 407.2

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
 
Standard
reference
number
Title Referenced
in code
section number
30A—15 Code for Motor Fuel Dispensing Facilities and Repair Garages 305.4, 305.10
37—15 Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines 616.1
51—13 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes 414.1
58—14 Liquefied Petroleum Gas Code 401.2, 402.6, 403.6.2, 403.11
70—14 National Electrical Code 306.3.1, 306.4.1, 306.5.2,
309.2, 310.1.1.2, 413.9.2.4, 703.6
82—14 Incinerators, Waste and Linen Handling Systems and Equipment 503.2.5, T503.4, 607.1
85—15 Boiler and Combustion Systems Hazards Code 631.1
88A—15 Parking Structures 305.9
211—13 Standard for the Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 503.5.2, 503.5.3,
503.5.6.1, 503.5.6.3
409—11 Standard for the Aircraft Hangars 305.11
853—15 Installation of Stationary Fuel Cell Power Systems 633.1

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062
 
Standard
reference
number
Title Referenced
in code
section number
103—2010 Factory-built Chimneys, Residential Type and Building Heating Appliances—with
Revisions through July 2012
506.1
127—2011 Factory-built Fireplaces 621.7
441—2010 Gas Vents 502.1
641—2010 Type L Low-temperature Venting Systems—with Revisions through May 2013 502.1
651—2011 Schedule 40 and 80 Rigid PVC Conduit and Fittings—with Revisions through March 2012 403.6.3
795—2011 Commercial-industrial Gas Heating Equipment—
with Revisions through September 2012
610.1, 618.1, 631.1
959—2010 Medium Heat Appliance Factory-built Chimneys 506.3
1618—09 Wall Protectors, Floor Protectors and Hearth Extensions—with Revisions through May 2013 308.2
1738—2010 Venting Systems for Gas Burning Appliances, Categories II, III and IV—
with Revisions through May 2011
502.1
1777—2007 Chimney Liners—with Revisions through July 2009 501.12, 501.15.4
2200—2012 Stationary Engine Generator Assemblies—with Revisions through June 2013 616.1
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING