Appendix N Supplemental Storm Shelter Requirements

AMENDMENT
This section has been amended at the state or city level.
The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.

Section N101 General

AMENDMENT
This section has been amended at the state or city level.

N101.1 Scope

AMENDMENT
This section has been amended at the state or city level.
The provisions of this appendix shall apply exclusively to the installation of storm shelters in critical emergency operation facilities and Group E occupancies.

N101.2 Design

AMENDMENT
This section has been amended at the state or city level.
Technical requirements for items herein shall comply with ICC 500® and Section 423.

Section N102 Critical Emergency Operations

AMENDMENT
This section has been amended at the state or city level.
All 911 call stations, emergency operations centers and normally occupied fire, ambulance, and police stations shall have a storm shelter constructed in accordance with ICC 500® and Section 423.
Exception: Entire Buildings meeting the requirements for shelter design in ICC 500® and Section 423.

Section N103 Group E Occupancies

AMENDMENT
This section has been amended at the state or city level.
All group E occupancies with an aggregate occupant load of 50 or more shall have a storm shelter constructed in accordance with ICC 500® and Section 423. The storm shelter shall be capable of housing the occupant load of the classrooms and administrative areas in the new building or addition containing the Group E occupancy.

Exceptions:
  1. Group E day care facilities.
  2. Group E occupancies accessory to places of religious worship.
  3. Entire buildings meeting the requirements for storm shelter design in ICC 500® and Section 423.