This chapter lists the standards that are referenced in various sections of this code. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title. The application of the referenced standards shall be as specified in Section 102.5.

When indicated in this code, the following codes refer to provisions in the listed chapters of the administrative code:

REFERENCED CODEOHIO ADMINISTRATIVE CODE CHAPTERS
Building Code4101:1-1 to 4101:1-35
Fire Code1301:7-1 to 1301:7-7
Mechanical Code4101:2-1 to 4101:2-15
Plumbing Code4101:3-1 to 4101:3-13, codified and published as the 2011 Ohio Plumbing Code, effective
11-1-2011 (including update effective 03-15-2012), and as modified in Section 2501.1.1.
AAMAAmerican Architectural Manufacturers Association
1827 Walden Office Square, Suite 550
Schaumburg, IL 60173
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S.2/A440—08
North American Fenestration Standards/Specifications for Windows, Doors and Skylights
450—10Voluntary Performance Rating Method for Mulled Fenestration Assemblies
506—08Voluntary Specifications for Hurricane Impact and Cycle Testing of Fenestration Products
711—07Voluntary Specification for Self Adhering Flashing Used for Installation of Exterior Wall Fenestration Products
ACIAmerican Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331
Standard
reference
number
TitleReferenced
in code
section number
318—08Building Code Requirements for Structural Concrete
332—08Code Requirements for Residential Concrete Construction
530—08Building Code Requirements for Masonry Structures
530.1—08Specification for Masonry Structures
ACCAAir Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
TitleReferenced
in code
section number
Manual D—09Residential Duct Systems
Manual J—04Residential Load Calculation—Eighth Edition
Manual S—04Residential Equipment Selection
AFPAAmerican Forest and Paper Association
1111 19th Street, NW, Suite 800
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
NDS—05National Design Specification (NDS) for Wood Construction—with 2005 Supplement
WFCM—01Wood Frame Construction Manual for One- and Two-family Dwellings
AFPA—93Span Tables for Joists and Rafters
PWF—07Permanent Wood Foundation Design Specification
AISIAmerican Iron and Steel Institute
1140 Connecticut Ave, Suite 705
Washington, DC 20036
Standard
reference
number
TitleReferenced
in code
section number
AISI S100—07North American Specification for the Design of Cold-formed Steel Structural Members
AISI S230—07Standard for Cold-formed Steel Framing-prescriptive Method for One- and Two-family Dwellings
AITCAmerican Institute of Timber Construction
7012 S. Revere Parkway, Suite 140
Centennial, CO 80112
Standard
reference
number
TitleReferenced
in code
section number
ANSI/AITC A 190.1—07Structural Glued Laminated Timber
ANSIAmerican National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
TitleReferenced
in code
section number
A108.1A—09Installation of Ceramic Tile in the Wet-set Method, with Portland Cement Mortar
A108.1B—09Installation of Ceramic Tile, Quarry Tile on a Cured Portland Cement Mortar Setting Bed with
Dry-set or Latex-Portland Mortar
A108.4—09Installation of Ceramic Tile with Organic Adhesives or Water Cleanable Tile-setting Epoxy Adhesive
A108.5—09Installation of Ceramic Tile with Dry-set Portland Cement Mortar or Latex-Portland Cement Mortar
A108.6—09Installation of Ceramic Tile with Chemical-resistant, Water-cleanable Tile-setting and -grouting Epoxy
A108.11—09Interior Installation of Cementitious Backer Units
A118.1—10.1American National Standard Specifications for Dry-set Portland Cement Mortar
A118.3—10.1American National Standard Specifications for Chemical-resistant, Water-cleanable Tile-setting and
Grouting Epoxy and Water-cleanable Tile-setting Epoxy Adhesive
A118.10—10.1Specification for Load Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone Installation
A136.1—10.1American National Standard Specifications for Organic Adhesives for Installation of Ceramic Tile
A137.1—08American National Standard Specifications for Ceramic Tile
A208.1—09Particleboard
LC1—05Interior Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing—with Addenda LC 1a-1999 and LC 1b-2001
LC4—07Press-connect Copper and Copper Alloy Fittings for use in Fuel Gas Distribution Systems
Z21.1—05Household Cooking Gas Appliances—with Addenda Z21.1a-2003 and Z21.1b-2003
Z21.5.1—06Gas Clothes Dryers—Volume I—Type I Clothes Dryers—with Addenda Z21.5.1a-2003
Z21.8—94 (R2002)Installation of Domestic Gas Conversion Burners
Z21.10.1—09Gas Water Heaters—Volume I—Storage Water Heaters with Input Ratings of 75,000 Btu per hour or Less
Z21.10.3—07Gas Water Heaters—Volume III—Storage Water Heaters with Input Ratings above 75,000 Btu per hour,
Circulating and Instantaneous Water Heaters—with Addenda Z21.10.3a-2003 and Z21.10.3b-2004
Z21.11.2—07Gas-fired Room Heaters—Volume II—Unvented Room Heaters—with Addenda Z21.11.2a-2003
Z21.13—10Gas-fired Low-Pressure Steam and Hot Water Boilers
Z21.15—09Manually Operated Gas Valves for Appliances, Appliance Connector Valves and Hose End Valves
with Addenda Z21.15a-2001 (R2003)
Z21.24—06Connectors for Gas Appliances
Z21.40.1—96 (R2002)Gas-fired, Heat-activated Air Conditioning and Heat Pump Appliances—with Z21.40.1a-97 (R2002)
Z21.40.2—96 (R2002)Gas-fired, Work-activated Air Conditioning and Heat Pump Appliances (Internal Combustion)—
with Z21.40.2a-1997 (R2002)
Z21.42—04Gas-fired Illuminating Appliances
Z21.47—06Gas-fired Central Furnaces
Z21.50—07Vented Gas Fireplaces—with Addenda Z21.50a-2003
Z21.56—06Gas-fired Pool Heaters—with Addenda Z21.56a-2004 and Z21.56b—2004
Z21.58—08Outdoor Cooking Gas Appliances—with Addenda Z21.58a-1998 (R2002) and Z21.58b-2002
Z21.60—03Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces—with Addenda Z21.60a-2003
Z21.75/CSA 6.27—07Connectors for Outdoor Gas Appliances
Z21.80—03Line Pressure Regulators
Z21.83—98Fuel Cell Power Plants
Z21.84—02Manually Listed, Natural Gas Decorative Gas Appliances for Installation in Solid Fuel-burning Fireplaces
with Addenda Z21.84a -2003
Z21.86—08Gas-fired Vented Space Heating Appliances
Z21.88—09Vented Gas Fireplace Heaters—with Addenda A21.88a-2003 and Z21.88b—2004
Z21.91—07Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters
Z83.6—90 (R1998)Gas-fired Infrared Heaters
Z83.8—09Gas-fired Unit Heaters and Gas-fired Duct Furnaces—with Addenda Z83.8a-2003
Z97.1—09Safety Glazing Materials Used in Buildings—Safety Performance Specifications and Methods of Test
APAAPA—The Engineered Wood Association
7011 South 19th
Tacoma, WA 98466
Standard
reference
number
TitleReferenced
in code
section number
APA E30—07Engineered Wood Construction Guide
ASCE/SEIAmerican Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191
Standard
reference
number
TitleReferenced
in code
section number
5—08Building Code Requirements for Masonry Structures
6—08Specification for Masonry Structures
7—05Minimum Design Loads for Buildings and Other Structures
24—05Flood-resistant Design and Construction
32—01Design and Construction of Frost-protected Shallow Foundations
ASHRAEAmerican Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
TitleReferenced
in code
section number
34—10Designation and Safety Classification of Refrigerants
ASHRAE—09ASHRAE Fundamentals Handbook—2009
ASMEAmerican Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
TitleReferenced
in code
section number
A17.1/CSA B44—04Safety Code for Elevators and Escalators
A18.1—03Safety Standard for Platforms and Stairway Chair Lifts
B1.20.1—1983 (R2006)Pipe Threads, General Purpose (Inch)
B16.33—2002 (R2007)Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig (Sizes 1/2 through 2)
B16.44—02Manually Operated Metallic Gas Valves For Use in Above-ground Piping Systems up to 5 psi
B36.10M—2004Welded and Seamless Wrought-steel Pipe
BPVC—2004ASME Boiler and Pressure Vessel Code
CSD-1—09Controls and Safety Devices for Automatically Fired Boilers
ASTMASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
TitleReferenced
in code
section number
A 36/A 36M—08Specification for Carbon Structural Steel
A 53/A 53M—10aSpecification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless
A 82/A 82M—07Specification for Steel Wire, Plain, for Concrete Reinforcement
A 106/A 106M—10Specification for Seamless Carbon Steel Pipe for High Temperature Service
A 153/A 153M—09Specification for Zinc Coating (Hot Dip) on Iron and Steel Hardware
A 167—09Specification for Stainless and Heat-resisting Chromium-nickel Steel Plate, Sheet and Strip
A 240/A 240M—10aStandard Specification for Chromium and Chromium-nickel Stainless Steel Plate, Sheet and
Strip for Pressure Vessels and for General Applications
A 254—07Specification for Copper Brazed Steel Tubing
A 307—07bSpecification for Carbon Steel Bolts and Studs, 6000 psi Tensile Strength
A 463/A 463M—09aStandard Specification for Steel Sheet, Aluminum-coated by the Hot-dip Process
A 510—08Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel
A 539—99Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines
A 615/A 615M—09bSpecification for Deformed and Plain Billet-steel Bars for Concrete Reinforcement
A 641/A 641M—09bSpecification for Zinc-coated (Galvanized) Carbon Steel Wire
A 653/A 653M—09aSpecification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-iron Alloy-coated (Galvanized) by the Hot-dip Process
A 706/A 706/M—09bSpecification for Low-alloy Steel Deformed and Plain Bars for Concrete Reinforcement
A 755/A 755M—03 (2008)Specification for Steel Sheet, Metallic Coated by the Hot-dip Process and Prepainted
by the Coil-coating Process for Exterior Exposed Building Products
A 778—01 (2009)e1Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products
A 792/A 792M—09aSpecification for Steel Sheet, 55% Aluminum-zinc Alloy-coated by the Hot-dip Process
A 875/A 875M—09aSpecification for Steel Sheet, Zinc-5%, Aluminum Alloy-coated by the Hot-dip Process
A 924/A 924M—10Standard Specification for General Requirements for Steel Sheet, Metallic-coated by the Hot-Dip Process
A 951—06Specification for Steel Wire Masonry Joint Reinforcement
A 996/A 996M—09bSpecifications for Rail-steel and Axel-steel Deformed Bars for Concrete Reinforcement
A 1003/A 1003M—10Standard Specification for Steel Sheet, Carbon, Metallic and Nonmetallic-coated for Cold-formed Framing Members
B 42—10Specification for Seamless Copper Pipe, Standard Sizes
B 43—09Specification for Seamless Red Brass Pipe, Standard Sizes
B 75—02Specification for Seamless Copper Tube
B 88—09Specification for Seamless Copper Water Tube
B 101—07Specification for Lead-coated Copper Sheet and Strip for Building Construction
B 135—10Specification for Seamless Brass Tube
B 209—07Specification for Aluminum and Aluminum-alloy Sheet and Plate
B 227—10Specification for Hard-drawn Copper-clad Steel Wire
B 251—10Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube
B 302—07Specification for Threadless Copper Pipe, Standard Sizes
B 306—09Specification for Copper Drainage Tube (DWV)
B 370—09Specification for Copper Sheet and Strip for Building Construction
B 447—07Specification for Welded Copper Tube
B 695—04 (2009)Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel
B 813—10Specification for Liquid and Paste Fluxes for Soldering Applications of Copper and Copper Alloy Tube
C 5—10Specification for Quicklime for Structural Purposes
C 27—98 (2008)Specification for Standard Classification of Fireclay and High-alumina Refractory Brick
C 28/C 28M—10Specification for Gypsum Plasters
C 33—08Specification for Concrete Aggregates
C 34—08Specification for Structural Clay Load-bearing Wall Tile
C 36/C 36M—03Specification for Gypsum Wallboard
C 37/C 37M—01Specification for Gypsum Lath
C 55—09Specification for Concrete Building Brick
C 59/C 59M—00 (2006)Specification for Gypsum Casting and Molding Plaster
C 61/C 61M—00 (2006)Specification for Gypsum Keene's Cement
C 62—10Specification for Building Brick (Solid Masonry Units Made from Clay or Shale)
C 73—05Specification for Calcium Silicate Face Brick (Sand Lime Brick)
C 79—04aSpecification for Treated Core and Nontreated Core Gypsum Sheathing Board
C 90—09Specification for Load-bearing Concrete Masonry Units
C 91—05Specification for Masonry Cement
C 94/C 94M—10Specification for Ready-mixed Concrete
C 129—06Specification for Nonload-bearing Concrete Masonry Units
C 143/C 143M—10aTest Method for Slump or Hydraulic Cement Concrete
C 145—85Specification for Solid Load-bearing Concrete Masonry Units
C 150—09Specification for Portland Cement
C 199—84 (2005)Test Method for Pier Test for Refractory Mortar
C 203—05aStandard Test Methods for Breaking Load and Flexural Properties of Block-type Thermal Insulation
C 207—06Specification for Hydrated Lime for Masonry Purposes
C 208—08aSpecification for Cellulosic Fiber Insulating Board
C 216—10Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)
C 270—10Specification for Mortar for Unit Masonry
C 272—01 (2007)Standard Test Method for Water Absorption of Core Materials for Structural Sandwich Constructions
C 273—07aStandard Test Method for Shear Properties of Sandwich Core Materials
C 315—07Specification for Clay Flue Liners and Chimney Pots
C 406—10Specifications for Roofing Slate
C 411—05Test Method for Hot-surface Performance of High-temperature Thermal Insulation
C 475/C 475—02 (2007)Specification for Joint Compound and Joint Tape for Finishing Gypsum Wallboard
C 476—10Specification for Grout for Masonry
C 514—04 (2009)e1Specification for Nails for the Application of Gypsum Wallboard
C 552—07Standard Specification for Cellular Glass Thermal Insulation
C 557—03 (2009)e1Specification for Adhesives for Fastening Gypsum Wallboard to Wood Framing
C 578—10Specification for Rigid, Cellular Polystyrene Thermal Insulation
C 587—04 (2009)Specification for Gypsum Veneer Plaster
C 588/C 588M—03e1Specification for Gypsum Base for Veneer Plasters
C 595—10Specification for Blended Hydraulic Cements
C 630/C 630M—03Specification for Water-resistant Gypsum Backing Board
C 631—09Specification for Bonding Compounds for Interior Gypsum Plastering
C 645—09aSpecification for Nonstructural Steel Framing Members
C 652—10Specification for Hollow Brick (Hollow Masonry Units Made from Clay or Shale)
C 685—10Specification for Concrete Made by Volumetric Batching and Continuous Mixing
C 728—05 (2010)Standard Specification for Perlite Thermal Insulation Board
C 836/C 836M—10Specification for High Solids Content, Cold Liquid-applied Elastomeric Waterproofing
Membrane for Use with Separate Wearing Course
C 843—99 (2006)Specification for Application of Gypsum Veneer Plaster
C 844—10Specification for Application of Gypsum Base to Receive Gypsum Veneer Plaster
C 847—10aSpecification for Metal Lath
C 887—05 (2010)Specification for Packaged, Dry, Combined Materials for Surface Bonding Mortar
C 897—05 (2009)Specification for Aggregate for Job-mixed Portland Cement-based Plasters
C 920—10Standard Specification for Elastomeric Joint Sealants
C 926—06Specification for Application of Portland Cement-based Plaster
C 931/C 931M—04Specification for Exterior Gypsum Soffit Board
C 933—09Specification for Welded Wire Lath
C 954—10Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster
Bases to Steel Studs from 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness
C 955—09aSpecification for Load-bearing (Transverse and Axial) Steel Studs, Runners (Tracks), and Bracing or
Bridging for Screw Application of Gypsum Panel Products and Metal Plaster Bases
C 957—10Specification for High-solids Content, Cold Liquid-applied Elastomeric Waterproofing
Membrane for Use with Integral Wearing Surface
C 960—04Specification for Predecorated Gypsum Board
C 1002—07Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases
C 1029—10Specification for Spray-applied Rigid Cellular Polyurethane Thermal Insulation
C 1032—06Specification for Woven Wire Plaster Base
C 1047—10aSpecification for Accessories for Gypsum Wallboard and Gypsum Veneer Base
C 1063—08Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-based Plaster
C 1107—08Standard Specification for Packaged Dry, Hydraulic-cement Grout (Nonshrink)
C 1116—10Standard Specification for Fiber-reinforced Concrete and Shotcrete
C 1167—03 (2009)Specification for Clay Roof Tiles
C 1177/C 1177M—08Specification for Glass Mat Gypsum Substrate for Use as Sheathing
C 1178/C 1178M—08Specification for Glass Mat Water-resistant Gypsum Backing Panel
C 1186—08Specification for Flat Nonasbestos Fiber Cement Sheets
C 1261—10Specification for Firebox Brick for Residential Fireplaces
C 1278/C 1278M—07aSpecification for Fiber-reinforced Gypsum Panels
C 1283—07aPractice for Installing Clay Flue Lining
C 1288—99 (2010)Standard Specification for Discrete Nonasbestos Fiber-cement Interior Substrate Sheets
C 1289—10Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
C 1325—08bStandard Specification for Nonasbestos Fiber-mat Reinforced Cement Interior Substrate Sheets
C 1328—05Specification for Plastic (Stucco) Cement
C 1395/C 1395M—06aSpecification for Gypsum Ceiling Board
C 1396/C 1396M—09aSpecification for Gypsum Board
C 1492—03 (2009)Specification for Concrete Roof Tile
C 1513—10Standard Specification for Steel Tapping Screws for Cold-formed Steel Framing Connections
C 1658/C 1658M—06Standard Specification for Glass Mat Gypsum Panels
D 41—05 (2010)Specification for Asphalt Primer Used in Roofing, Dampproofing and Waterproofing
D 43—00(2006)Specification for Coal Tar Primer Used in Roofing, Dampproofing and Waterproofing
D 225—07Specification for Asphalt Shingles (Organic Felt) Surfaced with Mineral Granules
D 226/D 226M—09Specification for Asphalt-saturated (Organic Felt) Used in Roofing and Waterproofing
D 227—03Specification for Coal Tar Saturated (Organic Felt) Used in Roofing and Waterproofing
D 312—00 (2006)Specification for Asphalt Used in Roofing
D 422—63 (2007)Test Method for Particle-size Analysis of Soils
D 449—03 (2008)Specification for Asphalt Used in Dampproofing and Waterproofing
D 450—07Specification for Coal-tar Pitch Used in Roofing, Dampproofing and Waterproofing
D 1227—95 (2007)Specification for Emulsified Asphalt Used as a Protective Coating for Roofing
D 1248—05Specification for Polyethylene Plastics Extrusion Materials for Wire and Cable
D 1622—08Standard Test Method for Apparent Density of Rigid Cellular Plastics
D 1623—09Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics
D 1693—08Test Method for Environmental Stress-cracking of Ethylene Plastics
D 1784—08Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated
Poly (Vinyl Chloride) (CPVC) Compounds
D 1863—05Specification for Mineral Aggregate Used in Built-up Roofs
D 1970—09Specification for Self-adhering Polymer Modified Bitumen Sheet Materials
Used as Steep Roofing Underlayment for Ice Dam Protection
D 2126—09Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging
D 2178—04Specification for Asphalt Glass Felt Used in Roofing and Waterproofing
D 2412—10Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading
D 2447—03Specification for Polyethylene (PE) Plastic Pipe Schedules 40 and 80, Based on Outside Diameter
D 2513—09aSpecification for Thermoplastic Gas Pressure Pipe, Tubing and Fittings
D 2559—10aStandard Specification for Adhesives for Structural Laminated Wood Products for
Use Under Exterior (West Use) Exposure Conditions
D 2626—04Specification for Asphalt-saturated and Coated Organic Felt Base Sheet Used in Roofing
D 2683—10Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing
D 2822—05Specification for Asphalt Roof Cement
D 2823—05Specification for Asphalt Roof Coatings
D 2824—06Specification for Aluminum-pigmented Asphalt Roof Coatings, Nonfibered, Asbestos Fibered and Fibered without Asbestos
D 2837—08Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials
or Pressure Design Basis for Thermoplastic Pipe Products
D 2846/D 2846M—09bSpecification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot- and Cold-water Distribution Systems
D 2898—10Test Methods for Accelerated Weathering of Fire-retardant-treated Wood for Fire Testing
D 3019—08Specification for Lap Cement Used with Asphalt Roll Roofing, Nonfibered, Asbestos Fibered and Nonasbestos Fibered
D 3035—08Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based On Controlled Outside Diameter
D 3161—09Test Method for Wind Resistance of Asphalt Shingles (Fan Induced Method)
D 3201—08ae1Test Method for Hygroscopic Properties of Fire-retardant Wood and Wood-base Products
D 3309—96a (2002)Specification for Polybutylene (PB) Plastic Hot- and Code-water Distribution System
D 3350—10Specification for Polyethylene Plastic Pipe and Fitting Materials
D 3462/D 3462M—10aSpecification for Asphalt Shingles Made From Glass Felt and Surfaced with Mineral Granules
D 3468—99 (2006)e01Specification for Liquid-applied Neoprene and Chlorosulfanated Polyethylene Used in Roofing and Waterproofing
D 3679—09aSpecification for Rigid Poly (Vinyl Chloride) (PVC) Siding
D 3737—09Practice for Establishing Allowable Properties for Structural Glued Laminated Timber (Glulam)
D 3747—79 (2007)Specification for Emulsified Asphalt Adhesive for Adhering Roof Insulation
D 3909—97b (2004)e01Specification for Asphalt Roll Roofing (Glass Felt) Surfaced with Mineral Granules.
D 3957—09Standard Practices for Establishing Stress Grades for Structural Members Used in Log Buildings,
D 4022—07Specification for Coal Tar Roof Cement, Asbestos Containing
D 4318—10Test Methods for Liquid Limit, Plastic Limit and Plasticity Index of Soils
D 4434/D 4434—09Specification for Poly (Vinyl Chloride) Sheet Roofing
D 4479—07Specification for Asphalt Roof Coatings-asbestos-free
D 4586—07Specification for Asphalt Roof Cement-asbestos-free
D 4601—04Specification for Asphalt-coated Glass Fiber Base Sheet Used in Roofing
D 4637/D 4637M—10Specification for EPDM Sheet Used in Single-ply Roof Membrane
D 4829—08aTest Method for Expansion Index of Soils
D 4869—05e01Specification for Asphalt-saturated (Organic Felt) Underlayment Used in Steep Slope Roofing
D 4897/D 4897M—01 (2009)Specification for Asphalt Coated Glass-fiber Venting Base Sheet Used in Roofing
D 4990—97a (2005)e01Specification for Coal Tar Glass Felt Used in Roofing and Waterproofing
D 5019—07aSpecification for Reinforced Nonvulcanized Polymeric Sheet Used in Roofing Membrane
D 5055—10Specification for Establishing and Monitoring Structural Capacities of Prefabricated Wood I-joists
D 5516—09Test Method for Evaluating the Flexural Properties of Fire-retardant-treated Softwood Plywood
Exposed to the Elevated Temperatures
D 5643—06Specification for Coal Tar Roof Cement Asbestos-free
D 5664—10Test Methods For Evaluating the Effects of Fire-retardant Treatments and Elevated Temperatures
on Strength Properties of Fire-retardant-treated Lumber
D 5665—99a (2006)Specification for Thermoplastic Fabrics Used in Cold-applied Roofing and Waterproofing
D 5726—98 (2005)Specification for Thermoplastic Fabrics Used in Hot-applied Roofing and Waterproofing
D 6083—05e01Specification for Liquid-applied Acrylic Coating Used in Roofing
D 6162—08Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials
Using a Combination of Polyester and Glass Fiber Reinforcements
D 6163—00 (2008)Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements
D 6164—05e1Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements
D 6222—08Specification for Atactic Polypropelene (APP) Modified Bituminous Sheet Materials Using Polyester Reinforcement
D 6223/D 6223M—02 (2009)Specification for Atactic Polypropelene (APP) Modified Bituminous Sheet Materials
Using a Combination of Polyester and Glass Fiber Reinforcement
D 6298—05e1Specification for Fiberglass-reinforced Styrene Butadiene Styrene (SBS) Modified Bituminous Sheets
with a Factory Applied Metal Surface
D 6305—08Practice for Calculating Bending Strength Design Adjustment Factors for Fire-retardant-treated Plywood Roof Sheathing
D 6380—03 (2008)Standard Specification for Asphalt Roll Roofing (Organic Felt)
D 6694—08Standard Specification Liquid-applied Silicone Coating Used in Spray Polurethane Foam Roofing
D 6754/D 6754M—10Standard Specification for Ketone-ethylene-ester-based Sheet Roofing
D 6757—07Standard Specification for Inorganic Underlayment for Use with Steep Slope Roofing Products
D 6841—08Standard Practice for Calculating Design Value Treatment Adjustment Factors for Fire-retardant-treated Lumber
D 6878—08e1Standard Specification for Thermoplastic-polyolefin-based Sheet Roofing
D 6947—07Standard Specification for Liquid Applied Moisture Cured Polyurethane Coating Used in Spray
Polyurethane Foam Roofing System
D 7032—10aStandard Specification for Establishing Perfomance Ratings for Wood-plastic Composite
Deck Boards and Guardrail Systems (Guards or Handrails)
D 7158—08dStandard Test Method for Wind Resistance of Sealed Asphalt Shingles (Uplift Force/Uplift Resistance Method)
E 84—10bTest Method for Surface Burning Characteristics of Building Materials
E 90—04Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
E 96/E 96M—05Test Method for Water Vapor Transmission of Materials
E 108—10aTest Methods for Fire Tests of Roof Coverings
E 119—10bTest Methods for Fire Tests of Building Construction and Materials
E 136—09bTest Method for Behavior of Materials in a Vertical Tube Furnace at 750°C
E 283—04Test Method for Determining the Rate of Air Leakage through Exterior Windows,
Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen
E 330—02 (2010)Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform
Static Air Pressure Difference
E 331—00 (2009)Test Method for Water Penetration of Exterior Windows, Skylights, Doors and Curtain Walls
by Uniform Static Air Pressure Difference
E 492—09Specification for Laboratory Measurement of Impact Sound Transmission through Floor-ceiling
Assemblies Using the Tapping Machine
E 814—10Test Method for Fire Tests of Through-penetration Firestops
E 970—10Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
E 1509—04Standard Specification for Room Heaters, Pellet Fuel-burning Type
E 1602—03 (2010)e1Guide for Construction of Solid Fuel Burning Masonry Heaters
E 1886—05Test Method for Performance of Exterior Windows, Curtain Walls, Doors and Storm Shutters
Impacted by Missles and Exposed to Cyclic Pressure Differentials
E 1996—09Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors
and Impact Protective Systems Impacted by Windborne Debris in Hurricanes
E 2178—03Standard Test Method for Air Permeance of Building Materials
E 2231—09Standard Practice for Specimen Preparation and Mounting of Pipe and Duct
Insulation Materials to Assess Surface Burning Characteristics
E 2273—03Standard Test Method for Determining the Drainage Efficiency of Exterior Insulation and
Finish Systems (EIFS) Clad Wall Assemblies
E 2568—09e1Standard Specification for PB Exterior Insulation and Finish Systems (EIFS)
E 2570—07Standard Test Methods for Evaluating Water-resistive Barrier (WRB) Coatings Used Under
Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
F 876—10Specification for Cross-linked Polyethylene (PEX) Tubing
F 877—07Specification for Cross-linked Polyethylene (PEX) Plastic Hot- and Cold-water Distribution Systems
F 1055—98 (2006)Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Fittings
F 1281—07Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe
F 1282—10Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe
F 1554—07aSpecification for Anchor Bolts, Steel, 36, 55 and 105-ksi Yield Strength
F 1667—10Specification for Driven Fasteners, Nails, Spikes and Staples
F 1807—10e1Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing
F 1960—10Specification for Cold Expansion Fittings with PEX Reinforcing Rings for Use with Cross-linked Polyethylene (PEX) Tubing
F 1973—08Standard Specification for Factory Assembled Anodeless Risers and Transition Fittings
in Polyethylene (PE) and Polyamide 11 (PA 11) Fuel Gas Distribution Systems.2
F 2090—10Specification for Window Fall Prevention Devices—with Emergency Escape (Egress) Release Mechanisms
F 2098—08Standard Specification for Stainless Steel Clamps for SDR9 PEX Tubing to Metal Insert Fittings
F 2389—10Standard for Pressure-rated Polypropylene (PP) Piping Systems
F 2623—08Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDRG Tubing
AWPAAmerican Wood Protection Association
P.O. Box 361784
Birmingham, AL 35236-1784
Standard
reference
number
TitleReferenced
in code
section number
C1—03All Timber Products—Preservative Treatment by Pressure Processes
M4—06Standard for the Care of Preservative-treated Wood Products
U1—10USE CATEGORY SYSTEM: User Specification for Treated Wood Except Section 6 Commodity Specification H
CGSBCanadian General Standards Board
Place du Portage 111, 6B1
11 Laurier Street
Gatineau, Quebec, Canada KIA 1G6
Standard
reference
number
TitleReferenced
in code
section number
37-GP—52M—(1984)Roofing and Waterproofing Membrane, Sheet Applied, Elastomeric
37-GP—56M—(1985)Membrane, Modified Bituminous, Prefabricated and Reinforced for Roofing—with December 1985 Amendment
CAN/CGSB-37.54—95Polyvinyl Chloride Roofing and Waterproofing Membrane
CPAComposite Panel Association
19465 Deerfield Avenue, Suite 306
Leesburg, VA 20176
Standard
reference
number
TitleReferenced
in code
section number
ANSI A135.4—04Basic Hardboard
ANSI A135.5—04Prefinished Hardboard Paneling
ANSI A135.6—06Hardboard Siding
CPSCConsumer Product Safety Commission
4330 East West Highway
Bethesda, MD 20814-4408
Standard
reference
number
TitleReferenced
in code
section number
16 CFR Part 1201—(1977)Safety Standard for Architectural Glazing
16 CFR Part 1209—(1979)Interim Safety Standard for Cellulose Insulation
16 CFR Part 1404—(1979)Cellulose Insulation
CSACanadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4N 5N6
Standard
reference
number
TitleReferenced
in code
section number
CSA Requirement 3—88Manually Operated Gas Valves for Use in House Piping Systems
CSA 8-93Requirements for Gas Fired Log Lighters for Wood Burning Fireplaces—with Revisions through January 1999
O325—07Construction Sheathing
O437-Series—93Standards on OSB and Waferboard (Reaffirmed 2006)
101/I.S.2/A440—08Specifications for Windows, Doors and Unit Skylights
B45.1—02Ceramic Plumbing Fixtures
CAN/CSA B137.10M—09Cross-linked Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems
CSSBCedar Shake & Shingle Bureau
P. O. Box 1178
Sumas, WA 98295-1178
Standard
reference
number
TitleReferenced
in code
section number
CSSB—97Grading and Packing Rules for Western Red Cedar Shakes and Western Red Shingles of the Cedar Shake and Shingle Bureau
DASMADoor and Access Systems Manufacturers
Association International
1300 Summer Avenue
Cleveland, OH 44115-2851
Standard
reference
number
TitleReferenced
in code
section number
108—05Standard Method for Testing Garage Doors: Determination of Structural Performance Under Uniform
Static Air Pressure Difference
DOCUnited States Department of Commerce
1401 Constitution Avenue, NW
Washington, DC 20230
Standard
reference
number
TitleReferenced
in code
section number
PS 1—07Structural Plywood
PS 2—04Performance Standard for Wood-based Structural-use Panels
R803.2.1/PS 20—05American Softwood Lumber Standard
DOTnDepartment of Transportation
1200 New Jersey Avenue SE
East Building, 2nd floor
Washington, DC 20590
Standard
reference
number
TitleReferenced
in code
section number
49 CFR, Parts 192.281(e) &
192.283 (b)
Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards
FEMAFederal Emergency Management Agency
500 C Street, SW
Washington, DC 20472
Standard
reference
number
TitleReferenced
in code
section number
TB-2—08Flood-resistant Materials Requirements
FIA-TB-11—01Crawlspace Construction for Buildings Located in Special Flood Hazard Area
FMFactory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P. O. Box 7500
Johnson, RI 02919
Standard
reference
number
TitleReferenced
in code
section number
4450—(1989)Approval Standard for Class 1 Insulated Steel Deck Roofs—with Supplements through July 1992
4880—(2010)American National Standard for Evaluating Insulated Wall or Wall and Roof/Ceiling Assemblies,
Plastic Interior Finish Materials, Plastic Exterior Building Panels, Wall/Ceiling Coating Systems,
Interior or Exterior Finish Systems
GAGypsum Association
810 First Street, Northeast, Suite 510
Washington, DC 20002-4268
Standard
reference
number
TitleReferenced
in code
section number
GA-253—07Application of Gypsum Sheathing
HPVAHardwood Plywood & Veneer Association
1825 Michael Faraday Drive
Reston, Virginia 20190-5350
Standard
reference
number
TitleReferenced
in code
section number
HP-1—2009The American National Standard for Hardwood and Decorative Plywood
ICCInternational Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington, DC 20001
Standard
reference
number
TitleReferenced
in code
section number
ICC/ANSI A117.1—09Accessible and Usable Buildings and Facilities
ICC 400—07Standard on the Design and Construction of Log Structures
ICC 500—08ICC/NSSA Standard on the Design and Construction of Storm Shelters
ICC 600—08Standard for Residential Construction in High Wind Regions
IEBC—09International Existing Buildings Code®
IECC—09International Energy Conservation Code® (adoption includes only Section101 of Chapter1 and Chapters2 through6)
IFGC—09International Fuel Gas Code® (including ICC Emergency Amendment changing Section 406.7)
ISOInternational Organization for Standardization
1, ch. de la Voie - Creuse
Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
reference
number
TitleReferenced
in code
section number
15874—03Polypropylene Plastic Piping Systems for Hot and Cold Water Installations
MSSManufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
Standard
reference
number
TitleReferenced
in code
section number
SP-58—09Pipe Hangers and SupportsMaterials, Design and Manufacture
NAIMANorth American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
TitleReferenced
in code
section number
AH 116—02Fibrous Glass Duct Construction Standards, Fifth Edition
NCMANational Concrete Masonry Association
13750 Sunrise Valley Drive
Herndon, VA 20171-4662
Standard
reference
number
TitleReferenced
in code
section number
TR 68-A—75Design and Construction of Plain and Reinforced Concrete Masonry and Basement and Foundation Walls
NFPANational Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Standard
reference
number
TitleReferenced
in code
section number
1310Installation of Sprinkler Systems (including TIA 10-2)
13D—10Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings
and Manufactured Homes (including TIA 10-2)
13R—10Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including
Four Stories in Height (including TIA 10-2)
31—06Installation of Oil-burning Equipment
58—11Liquefied Petroleum Gas Code
70—11National Electrical Code(including TIA 11-1)
72—10National Fire Alarm Code
85—07Boiler and Construction Systems Hazards Code
211—10Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances
259—08Test Method for Potential Heat of Building Materials
286—06Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
501—05Standard on Manufactured Housing
853—10Standard for the Installation of Stationary Fuel Cell Power Systems
NFRCNational Fenestration Rating Council Inc.
8484 Georgia Avenue, Suite 320
Silver Spring, MD 20910
Standard
reference
number
TitleReferenced

section number
100—10Procedure for Determining Fenestration Product U-factors
200—10Procedure for Determining Fenestration Product Solar Heat Gain Coefficients
and Visible Transmittance at Normal Incidence
400—10Procedure for Determining Fenestration Product Air Leakage
PCAPortland Cement Association
5420 Old Orchard Road
Skokie, IL 60077
Standard
reference
number
TitleReferenced
in code
section number
100—07Prescriptive Design of Exterior Concrete Walls for One- and Two-family Dwellings (Pub. No. EB241)
SMACNASheet Metal & Air Conditioning Contractors National Assoc. Inc.
4021 Lafayette Center Road
Chantilly, VA 22021
Standard
reference
number
TitleReferenced
in code
section number
SMACNA—03Fibrous Glass Duct Construction Standards (2003)
TMSThe Masonry Society
3970 Broadway, Suite 201-D
Boulder, CO 80304
Standard
reference
number
TitleReferenced
in code
section number
302—07Standard Method for Determining the Sound Transmission Class Rating for Masonry Walls
402—08Building Code Requirements for Masonry Structures
602—08Specification for Masonry Structures
TPITruss Plate Institute
583 D'Onofrio Drive, Suite 200
Madison, WI 53719
Standard
reference
number
TitleReferenced
in code
section number
TPI 1—2007National Design Standard for Metal-plate-connected Wood Truss Construction
ULUnderwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
Standard
reference
number
TitleReferenced
in code
section number
17—08Vent or Chimney Connector Dampers for Oil-fired Appliances—with Revisions through September 1999
58—96Steel Underground Tanks for Flammable and Combustible Liquids—with Revisions through July 1998
80—07Steel Tanks for Oil-burner Fuel
103—10Factory-built Chimneys for Residential Type and Building Heating Appliances—with Revisions through June 2006
127—08Factory-built Fireplaces—with Revisions through November 2006
174—04Household Electric Storage Tank Water Heaters—with Revisions through November 2005
181—05Factory-made Air Ducts and Air Connectors—with Revisions through May 2003
181A—05Closure Systems for Use with Rigid Air Ducts and Air Connectors—with Revisions through December 1998
181B—05Closure Systems for Use with Flexible Air Ducts and Air Connectors—with Revisions through August 2003
217—06Single- and Multiple-station Smoke Alarms—with Revisions through January 2004
263—03Standards for Fire Test of Building Construction and Materials
325—02Standard for Door, Drapery, Gate, Louver and Window Operations and Systems—with Revisions through February 2006
343—08Pumps for Oil-burning Appliances—with Revisions through May 2002
441—10Gas Vents—with Revisions through August 2006
508—99Industrial Control Equipment—with Revisions through July 2005
536—97Flexible Metallic Hose—with Revisions through June 2003
641—95Type L, Low-temperature Venting Systems—with Revisions through August 2005
651—05Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings
723—08Standard for Test for Surface Burning Characteristics of Building Materials—with Revisions through May 2005
726—95Oil-fired Boiler Assemblies—with Revisions through March 2006
727—06Oil-fired Central Furnaces
729—03Oil-fired Floor Furnaces
730—03Oil-fired Wall Furnaces
732—95Oil-fired Storage Tank Water Heaters—with Revisions through February 2005
737—07Fireplaces Stoves—with Revisions through January 2000
790—04Standard Test Methods for Fire Tests of Roof Coverings
795—06Commercial-industrial Gas Heating Equipment
834—04Heating, Water Supply and Power Boilers-Electric
896—93Oil-burning Stoves—with Revisions through May 2004
923—08Microwave Cooking Appliances—with Revisions through February 2006
959—01Medium Heat Appliance Factory-built Chimneys—with Revisions through September 2006
1040—96Fire Test of Insulated Wall Construction—with Revisions through June 2001
1256—02Fire Test of Roof Deck Construction
1261—01Electric Water Heaters for Pools and Tubs—with Revisions through June 2004
1453—04Electronic Booster and Commercial Storage Tank Water Heaters
1479—03Fire Tests of Through-penetration Firestops
1482—10Solid-fuel-type Room Heaters—with Revisions through January 2000
1715—97Fire Test of Interior Finish Material—with Revisions through March 2004
1738—10Venting Systems for Gas-burning Appliances, Categories II, III and IV
1777—07Standard for Chimney Liners
1995—05Heating and Cooling Equipment
2017—08Standard for General-purpose Signaling Devices and Systems—with Revisions through June 2004
2034—08Standard for Single- and Multiple-station Carbon Monoxide Alarms
2158A—10Outline of Investigation for Clothes Dryer Transition Duct
ULCUnderwriters' Laboratories of Canada
7 Underwriters Road
Toronto, Ontario, Canada M1R 3B4
Standard
reference
number
TitleReferenced
in code
section number
CAN/ULC S 102—10Standard Methods for Test for Surface Burning Characteristics
of Building Materials and Assemblies—with 2000 Revisions
US-FTCUnited States - Federal Trade Commission
600 Pennsylvania Avenue NW
Washington, DC 20580
Standard
reference
number
TitleReferenced
in code
section number
CFR Title 16 Part 460R-value Rule
WDMAWindow & Door Manufacturers Association
1400 East Touhy Avenue, Suite 470
Des Plaines, IL 60018
Standard
reference
number
TitleReferenced
in code
section number
AAMA/WDMA/CSA
101/I.S2/A440—08
Specifications for Windows, Doors and Skylights