Heads up: There are no amended sections in this chapter.
This chapter lists the codes and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and the title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.5 of the building code.

When indicated in the "OPC," the following codes refer to provisions in the listed chapters of the Administrative Code:

Referenced CodeOhio Administrative Code Chapters
Building Code4101:1-1 to 4101:1-35
Fire Code1301:7-1 to 1301:7-7
Mechanical Code4101:2-1 to 4101:2-15
Ohio Boiler and Pressure Vessel Rules4101:4-1 to 4101:4-10

ANSI

American National Standards Institute
25 West 43rd Street, Fourth Floor
New York NY 10036
Standard
Reference
Number
TitleReferenced
in code
section number

A118.10—10

Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic Tile and Dimension Stone Installation

Z4.3—95 (R2005)

Minimum Requirements for Nonsewered Waste-disposal Systems (Standard is developed by the Portable Sanitation Association International-PSAI)

Z21.22—99 (R2003)

Relief Valves for Hot Water Supply Systems with Addenda Z21.22a-2000 (R2003) and Z21.22b-2001 (R2003) (Standard is developed by the Canadian Standards Association- CSA and is the same as CSA 4.4-M99)

Z124.1.205

Plastic Bathtub and Shower Units (Standard is developed by IAPMO)

Z124.3—05

Plastic Lavatories (Standard is developed by IAPMO)

Z124.4—06

Plastic Water Closet Bowls and Tanks (Standard is developed by IAPMO)

Z124.6—07

Plastic Sinks (Standard is developed by IAPMO)

Z124.9—04

Plastic Urinal Fixtures (Standard is developed by IAPMO)

AHRI

Air-Conditioning, Heating, & Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington VA 22203
Standard
Reference
Number
TitleReferenced
in code
section number

1010—02

Self-contained, Mechanically Refrigerated Drinking-Water Coolers

410.1

ASME

American Society of Mechanical Engineers
Three Park Avenue
New York NY 10016-5990
Standard
Reference
Number
TitleReferenced
in code
section number

A112.1.2—2004

Air Gaps in Plumbing Systems

A112.1.3—2000 (R2005)

Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances

A112.3.1—2007

Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground

A112.3.4—2000 (R2004)

Macerating Toilet Systems and Related Components Water Heater Relief Valve Drain Tubes

A112.4.1—2009

Water Heater Relief Valve Drain Tubes

A112.4.2—2008

Water Closet Personal Hygiene Devices

A112.4.3—1999 (R2004)

Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System

A112.6.1M—1997 (R2002)

Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use

A112.6.2—2000 (R2004)

Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks

A112.6.3—2001 (R2007)

2001 Floor and Trench Drains

A112.6.7—2001 (Reaffirmed 2007)

Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks

A112.14.1—2003

Backwater Valves

A112.14.3—2000

Grease Interceptors

A112.14.4—2001 (R2007)

Grease Removal Devices

A112.18.1/CSA B125.1-2005

Plumbing Supply Fittings

A112.18.2/CSA B125.2-2005

Plumbing Waste Fittings

A112.18.3—2002

Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings

A112.18.6/CSA B125.6-2009

Flexible Water Connectors

A112.18.7—1999 (R2004)

Deck mounted Bath/Shower Transfer Valves with Integral Backflow Protection

A112.19.1/CSA B45.2-2008

Enameled Cast Iron Plumbing Fixtures

A112.19.2/CSA B45.1-2008

Vitreous China Plumbing Fixtures and Hydraulic Requirements for Water Closets and Urinals

A112.19.3/CSA B45.4-2008

Stainless Steel Plumbing Fixtures (Designed for Residential Use)

A112.19.4M—1994 (R2004)

Porcelain Enameled Formed Steel Plumbing Fixtures

A112.19.5/CSA B45.15-2005

Trim for Water-closet Bowls, Tanks and Urinals

A112.19.7/CSA B45.10-2006

Hydromassage Bathtub Appliances

A112.19.12—2006

Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems

A112.19.15— 2005

Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors

A112.19.19—2006

Vitreous China Nonwater Urinals

A112.21.2M—1983

Roof Drains

A112.36.2M—1991(R2002)

Cleanouts

B1.20.1—1983(R2006)

Pipe Threads, General Purpose (inch)

B16.3—2006

Malleable Iron Threaded Fittings Classes 150 and 300

B16.4—2006

Gray Iron Threaded Fittings Classes 125 and 250

B16.9—2007

Factory-made Wrought Steel Buttwelding Fittings

B16.11—2009

Forged Fittings, Socket-welding and Threaded

B16.12—2009

Cast-iron Threaded Drainage Fittings

B16.15—2006

Cast Bronze Threaded Fittings

B16.18—2001 (R2005)

Cast Copper Alloy Solder Joint Pressure Fittings

B16.22—2001 (R2005)

Wrought Copper and Copper Alloy Solder Joint Pressure Fittings

B16.23—2002 (R2006)

Cast Copper Alloy Solder Joint Drainage Fittings DWV

B16.26—2006

Cast Copper Alloy Fittings for Flared Copper Tubes

B16.28—1994

Wrought Steel Buttwelding Short Radius Elbows and Returns

B16.29—2007

Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV)

BPVC Section IX—2010

Welding and Brazing Qualifications

ASSE

American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake OH 44145
Standard
Reference
Number
TitleReferenced
in code
section number

100108

Performance Requirements for Atmospheric Type Vacuum Breakers

100208

Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks

100309

Performance Requirements for Water Pressure Reducing Valves

100408

Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines

1005—99

Performance Requirements for Water Heater Drain Valves

1006—86

Performance Requirements for Residential Use Dishwashers

1007—86

Performance Requirements for Home Laundry Equipment

1008—06

Performance Requirements for Household Food Waste Disposer Units

1010—04

Performance Requirements for Water Hammer Arresters

1011—04

Performance Requirements for Hose Connection Vacuum Breakers

1012—09

Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent

1013—09

Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Fire Protection Principle Backflow Preventers

1015—09

Performance Requirements for Double Check Backflow Prevention Assemblies and Double Check Fire Protection Backflow Prevention Assemblies

1016—05

Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings

1017—09

Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution Systems

1018—01

Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied

1019—04

Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type

1020—04

Performance Requirements for Pressure Vacuum Breaker Assembly

1022—03

Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment

1024—04

Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets)

1035—08

Performance Requirements for Laboratory Faucet Backflow Preventers

1037—90

Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures

1044—01

Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types

1047—09

Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies

1048—09

Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies

1050—09

Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems

1051—09

Performance Requirements for Individual and Branch Type Air Admittance Valves for Sanitary Drainage Systems-fixture and Branch Devices

1052—04

Performance Requirements for Hose Connection Backflow Preventers

1055—09

Performance Requirements for Chemical Dispensing Systems

1056—01

Performance Requirements for Spill Resistant Vacuum Breaker

1060—06

Performance Requirements for Outdoor Enclosures for Backflow Prevention Assemblies

1061—06

Performance Requirements for Removable and Nonremovable Push Fit Fittings

1062—06

Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Fixture Fittings

1066—97

Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings

1069—05

Performance Requirements for Automatic Temperature Control Mixing Valves

1070—04

Performance Requirements for Water-temperature Limiting Devices

1072—07

Performance Requirements for Barrier Type Floor Drain Trap Seal Protection Devices

1079—05

Dielectric Pipe Unions

5013—09

Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Principle Backflow Preventers (RFP)

5015—09

Performance Requirements for Testing Double Check Valve Backflow Prevention Assembly (DCVA)

5020—09

Performance Requirements for Testing Pressure Vacuum Breaker Assembly (PVBA)

5047—09

Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA)

5048—09

Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)

5052—09

Performance Requirements for Testing Hose Connection Backflow Preventers

5056—09

Performance Requirements for Testing Spill Resistant Vacuum Breaker

ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken PA 19428-2959
Standard
Reference
Number
TitleReferenced
in code
section number

A 53/A 53M—10

Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless

A 74—09

Specification for Cast-iron Soil Pipe and Fittings

A 312/A 312M—09

Specification for Seamless and Welded Austenitic Stainless Steel Pipes

A 733—03 (2009)e1

Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples

A 778—01 (2009)e1

Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products

A 888—09

Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application

B 32—08

Specification for Solder Metal

B 42—10

Specification for Seamless Copper Pipe, Standard Sizes

B 43—09

Specification for Seamless Red Brass Pipe, Standard Sizes

B 75—02

Specification for Seamless Copper Tube

B 88—09

Specification for Seamless Copper Water Tube

B 152/B 152M—09

Specification for Copper Sheet, Strip Plate and Rolled Bar

B 251—10

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

B 302—07

Specification for Threadless Copper Pipe, Standard Sizes

B 306—09

Specification for Copper Drainage Tube (DWV)

B 447—07

Specification for Welded Copper Tube

B 687—99 (2005)e01

Specification for Brass, Copper and Chromium-plated Pipe Nipples

B 813—10

Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube

B 828—02

Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

C 4—04 (2009)

Specification for Clay Drain Tile and Perforated Clay Drain Tile

C 14—07

Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe

C 76—10a

Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe

C 296—00 (2009)e1

Specification for Asbestos-cement Pressure Pipe

C 425—04 (2009)

Specification for Compression Joints for Vitrified Clay Pipe and Fittings

C 428—97 (2006)

Specification for Asbestos-cement Nonpressure Sewer Pipe

C 443—05ae1

Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets

C 508—00 (2009)e1

Specification for Asbestos-cement Underdrain Pipe

C 564—09a

Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings

C 700—09

Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated

C 1053—00 (2010)

Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications

C 1173—08

Specification for Flexible Transition Couplings for Underground Piping System

C 1277—09a

Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings

C 1440—08

Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste,and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems

C 1460—08

Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground

C 1461—08

Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use

C 1540—09a

Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings

C 1563—08

Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications.

D 1527—99 (2005)

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80

D 1785—06

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120

D 1869—95 (2005)

Specification for Rubber Rings for Asbestos-cement Pipe

D 2235—04

Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings

D 2239—03

Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on Controlled Inside Diameter

D 2241—09

Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)

D 2282—(2005)99e01

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)

D 2464—06

Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

D 2466—06

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40

D 2467—06

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

D 2468—96a

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40

D 2564—04e01

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems

D 2609—02

Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe

D 2657—07

Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting

D 2661—08

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings

D 2665—09

Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings

D 2672—96a (2009)

Specification for Joints for IPS PVC Pipe Using Solvent Cement

D 2683—10

Standard Specification for Socket-type Polyethylene fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing

D 2729—03

Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

D 2737—03

Specification for Polyethylene (PE) Plastic Tubing

D 2751—05

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings

D 2846/D 2846M—09b

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems

D 2855—96 (2010)

Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings

D 3034—08

Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings

D 3035—08

Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter

D 3139—98 (2005)

Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals

D 3212—07

Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals

D 3261—10a

Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic fittings for Polyethylene (PE) Plastic Pipe and Tubing

D 3311—09a

Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns

D 4068—09

Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane

D 4551—96 (2008)e1

Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane

F 405—05

Specification for Corrugated Polyethylene (PE) Tubing and Fittings

F 409—02 (2008)

Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings

F 437—09

Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

F 438—09

Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

F 439—09

Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

F 441/F 441M—09

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80

F 442/F 442M—09

Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR)

F 477—10

Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe

F 493—10

Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings

F 628—08

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core

F 656—10

Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings

F 714—08

Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter

F 876—10

Specification for Cross-linked Polyethylene (PEX) Tubing

F 877—07

Specification for Cross-linked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems

F 891—10

Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core

F 1055—98(2006)

Standard Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Tubing

F 1281—07

Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX) Pressure Pipe

F 1282—10

Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe

F 1412—09

Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage

F 1488—09

Specification for Coextruded Composite Pipe

F 1673—10

Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems

F 1807—07

Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing

F 1866—07

Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings

F 1960—10

Specification for Cold Expansion Fittings with PEX Reinforcing Rings for use with Cross-linked Polyethylene (PEX) Tubing

F 1974—09

Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe

F 1986—01(2006)

Specification for Multilayer Pipe, Type 2, Compression Fittings and Compression Joints for Hot and Cold Drinking Water Systems

F 2080—09

Specifications for Cold-expansion Fittings with Metal Compression-sleeves for Cross-linked Polyethylene (PEX) Pipe

F 2098—08

Standard specification for Stainless Steel Clamps for Securing SDR9 Cross-linked Polyethylene (PEX) Tubing to Metal Insert Fittings

F 2159—10

Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing

F 2262—09

Specification for Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Tubing OD Controlled SDR9

F 2306/F 2306M—08

12" to 60" Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications

F 2389—10

Specification for Pressure-rated Polypropylene (PP) Piping Systems

F 2434—09

Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX AL-PEX) Tubing

F 2735—09

Standard Specification for SDR9 Cross-linked Polyethylene (PEX) and Raised Temperature (PE-RT) Tubing

F 2769—09

Polyethylene or Raised Temperature (PE-RT) Plastic Hot and Cold Water Tubing and Distribution Systems

AWS

American Welding Society
550 N.W. LeJeune Road
Miami FL 33126
Standard
Reference
Number
TitleReferenced
in code
section number

A5.8—04

Specifications for Filler Metals for Brazing and Braze Welding

AWWA

American Water Works Association
6666 West Quincy Avenue
Denver CO 80235
Standard
Reference
Number
TitleReferenced
in code
section number

C104/A21.4—08

Standard for Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water

C110/A21.10—08

Standard for Ductile-iron and Gray-iron Fittings, 3 Inches through 48 Inches, for Water

C111/A21.11—06

Standard for Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings

C115/A21.15—05

Standard for Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges

C151/A21.51—09

Standard for Ductile-iron Pipe, Centrifugally Cast for Water

C153/A21.53—06

Standard for Ductile-iron Compact Fittings for Water Service

C510—07

Double Check Valve Backflow Prevention Assembly

C511—07

Reduced-pressure Principle Backflow Prevention Assembly

C651—05

Disinfecting Water Mains

C652—02

Disinfection of Water-storage Facilities

C901—08

Polyethylene (PE) Pressure Pipe and Tubing 1/2 Inch (13 mm) through 3 Inch (76 mm) for Water Service

C904—08

Cross-linked Polyethylene (PEX) Pressure Pipe 1/2 Inch (13 mm) through 3 Inch (76 mm) for Water Service

CISPI

Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga TN 37421
Standard
Reference
Number
TitleReferenced
in code
section number

30109

Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

31009

Specification for Coupling for Use in Connection with Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

CSA

Canadian Standards Association
5060 Spectrum Way.
Mississauga, Ontario Canada L4W 5N6
Standard
Reference
Number
TitleReferenced
in code
section number

B45.1/ASME A112.19.2—02(R2008)

Ceramic Plumbing Fixtures

B45.2/ASME A112.19.1—02(R2008)

Enameled Cast-iron Plumbing Fixtures

B45.3—02 (R2008)

Porcelain Enameled Steel Plumbing Fixtures

B45.4/ASME A112.19.3—02(R2008)

Stainless-steel Plumbing Fixtures

B45.5—02 (R2008)

Plastic Plumbing Fixtures

B45.9—99 (R2008)

Macerating Systems and Related Components

B45.10/ASME A112.19.7—-09

Hydromassage Bathtub Appliances

B45.15/ASME A112.19.5—09

Trim for Water-closet Bowls, Tanks, and Urinals

B64.1.2—07

Vacuum Breakers, Pressure Type (PVB)

B64.2.1—07

Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature

B64.2.1.1—07

Vacuum Breakers, Hose Connection Dual Check Type (HCDVB)

B64.4.1—07

Backflow Preventers, Reduced Pressure Principle Type for Fire Sprinklers (RPF)

B64.5—07

Backflow Preventers, Double Check Type (DCVA)

B64.5.1—07

Backflow Preventers, Double Check Type for Fire Systems (DCVAF)

B64.6—07

Backflow Preventers, Dual Check Valve Type (DuC)

B64.7—07

Vacuum Breakers, Laboratory Faucet Type (LFVB

B64.10/B64.10.1—07

Manual for the Selection and Installation of Backflow Prevention Devices/Manual for the Maintenance and Field Testing of Backflow Prevention Devices

B79—08

Floor, Area and Shower Drains, and Cleanouts for Residential Construction

B125—01

Plumbing Fittings

B125.1/ASME A112.18.1—05

Plumbing Supply Fittings

B125.2/ASME A112.18.2—05

Plumbing Waste Fittings

B125.3—2005

Plumbing Fittings

B125.6/ASME A112.18.6—09

Flexible Water Connectors

B137.1—09

Polyethylene Pipe, Tubing and Fittings for Cold Water Pressure Services

B137.2—09

PVC Injection-moulded Gasketed Fittings for Pressure Applications

B137.3—09

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications

B137.5—09

Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications—with Revisions through September 1992

B137.6—09

CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems—with Revisions through May 1986

B181.1—06

ABS Drain, Waste and Vent Pipe and Pipe Fittings

B181.2—06

PVC Drain, Waste, and Vent Pipe and Pipe Fittings—with Revisions through December 1993

B182.1—06

Plastic Drain and Sewer Pipe and Pipe Fittings

B182.2—06

PVC Sewer Pipe and Fittings (PSM Type)

B182.4—06

Profile PVC Sewer Pipe and Fittings

B182.6—06

Profile Polyethylene Sewer Pipe and Fittings for Leak-proof Sewer Applications

B182.8—06

Profile Polyethylene Storm Sewer and Drainage Pipe and Fittings

B356—05

Water Pressure Reducing Valves for Domestic Water Systems

B483.1—07

Drinking Water Treatment Units

CAN/CSA-A257.1M—09

Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

CAN/CSA-A257.2M—09

Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings

CAN/CSA-A257.3M—09

Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets

CAN/CSA-B64.1.1—07

Vacuum Breakers, Atmospheric Type (AVB)

CAN/CSA-B64.2—07

Vacuum Breakers, Hose Connection Type (HCVB)

CAN/CSA-B64.2.2—07

Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature

CAN/CSA-B64.3—07

Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)

CAN/CSA-B64.4—07

Backflow Preventers, Reduced Pressure Principle Type (RP)

CAN/CSA-B64.10—07

Manual for the Selection, Installation, Maintenance and Field Testing of Backflow Prevention Devices

CAN/CSA-B137.9—09

Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems

CAN/CSA-B137.10M—09

Cross-linked Polyethylene/Aluminum/Polyethylene Composite Pressure Pipe Systems

CAN/CSA-B181.3—06

Polyolefin Laboratory Drainage Systems

CAN/CSA-B182.4—06

Profile PVC Sewer Pipe and Fittings

CAN/CSA-B602—10

Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe

ICC

International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington DC 20001
Standard
Reference
Number
TitleReferenced
in code
section number

IFGC—09

International Fuel Gas Code Code (including ICC Emergency Amendment changing IFGC Sections 406.7)

ISEA

International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington VA 22209
Standard
Reference
Number
TitleReferenced
in code
section number

Z358.1—09

Emergency Eyewash and Shower Equipment

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471
Standard
Reference
Number
TitleReferenced
in code
section number

70—14

National Electric Code

99C—05

Gas and Vacuum Systems

NSF

NSF International
789 Dixboro Road
Ann Arbor MI 48105
Standard
Reference
Number
TitleReferenced
in code
section number

32009

Commercial Warewashing Equipment

14—2010

Plastic Piping System Components and Related Materials

18—2009

Manual Food and Beverage Dispensing Equipment

42—2009

Drinking Water Treatment Units—Aesthetic Effects

44—2009

Residential Cation Exchange Water Softeners

53—2009e

Drinking Water Treatment Units—Health Effects

58—2009

Reverse Osmosis Drinking Water Treatment Systems

61—2010a

Drinking Water System Components—Health Effects

62—2009

Drinking Water Distillation Systems

372—2010

Drinking Water System Components—Lead Content

PDI

Plumbing and Drainage Institute
800 Turnpike Street, Suite 300
North Andover MA 01845
Standard
Reference
Number
TitleReferenced
in code
section number

G101 (2010)

Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data

UL

Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook IL 60062-2096
Standard
Reference
Number
TitleReferenced
in code
section number

UL508—99

Industrial Control Equipment with Revision through July 2005