UpCodes logo

2017 Ohio Fire Code

ADOPTS WITH AMENDMENTS:

International Fire Code 2015 (IFC 2015)

Ohio Administrative Code 1301:7-7-01 Scope and Administration
Go to chapter icon
Ohio Administrative Code 1301:7-7-02 Definitions
Go to chapter icon
Ohio Administrative Code 1301:7-7-03 General Requirements
Go to chapter icon
Ohio Administrative Code 1301:7-7-04 Emergency Planning and Preparedness
Go to chapter icon
Ohio Administrative Code 1301:7-7-05 Fire Service Features
Go to chapter icon
Ohio Administrative Code 1301:7-7-06 Building Services and Systems
Go to chapter icon
Ohio Administrative Code 1301:7-7-07 Fire and Smoke Protection Features
Go to chapter icon
Ohio Administrative Code 1301:7-7-08 Interior Finish, Decorative Materials and Furnishings
Go to chapter icon
Ohio Administrative Code 1301:7-7-09 Fire Protection Systems
Go to chapter icon
Ohio Administrative Code 1301:7-7-10 Means of Egress
Go to chapter icon
Ohio Administrative Code 1301:7-7-11 Construction Requirements for Existing Buildings
Go to chapter icon
Chapter 12 Through 19 Reserved
Go to chapter icon
Ohio Administrative Code 1301:7-7-20 Aviation Facilities
Go to chapter icon
Ohio Administrative Code 1301:7-7-21 Dry Cleaning
Go to chapter icon
Ohio Administrative Code 1301:7-7-22 Combustible Dust-Producing Operations
Go to chapter icon
Ohio Administrative Code 1301:7-7-23 Motor Fuel-Dispensing Facilities and Repair Garages
Go to chapter icon
Ohio Administrative Code 1301:7-7-24 Flammable Finishes
Go to chapter icon
Ohio Administrative Code 1301:7-7-25 Fruit and Crop Ripening
Go to chapter icon
Ohio Administrative Code 1301:7-7-26 Fumigation and Insecticidal Fogging
Go to chapter icon
Ohio Administrative Code 1301:7-7-27 Semiconductor Fabrication Facilities
Go to chapter icon
Ohio Administrative Code 1301:7-7-28 Lumber Yards and Agro-Industrial, Solid Biomass and Woodworking Facilities
Go to chapter icon
Ohio Administrative Code 1301:7-7-29 Manufacture of Organic Coatings
Go to chapter icon
Ohio Administrative Code 1301:7-7-30 Industrial Ovens
Go to chapter icon
Ohio Administrative Code 1301:7-7-31 Tents and Other Membrane Structures
Go to chapter icon
Ohio Administrative Code 1301:7-7-32 High-Piled Combustible Storage
Go to chapter icon
Ohio Administrative Code 1301:7-7-33 Fire Safety During Construction and Demolition
Go to chapter icon
Ohio Administrative Code 1301:7-7-34 Tire Rebuilding and Tire Storage
Go to chapter icon
Ohio Administrative Code 1301:7-7-35 Welding and Other Hot Work
Go to chapter icon
Ohio Administrative Code 1301:7-7-36 Marinas
Go to chapter icon
Ohio Administrative Code 1301:7-7-37 Combustible Fibers
Go to chapter icon
Chapter 38 Reserved
Go to chapter icon
Ohio Administrative Code 1301:7-7-39 Plant Processing and Extraction Facilities
Go to chapter icon
Chapter 40 Through 49 Reserved
Go to chapter icon
Ohio Administrative Code 1301:7-7-50 Hazardous Materials—General Provisions
Go to chapter icon
Ohio Administrative Code 1301:7-7-51 Aerosols
Go to chapter icon
Chapter 52 Reserved
Go to chapter icon
Ohio Administrative Code 1301:7-7-53 Compressed Gases
Go to chapter icon
Ohio Administrative Code 1301:7-7-54 Corrosive Materials
Go to chapter icon
Ohio Administrative Code 1301:7-7-55 Cryogenic Fluids
Go to chapter icon
Ohio Administrative Code 1301:7-7-56 Explosives and Fireworks
Go to chapter icon
Ohio Administrative Code 1301:7-7-57 Flammable and Combustible Liquids
Go to chapter icon
Ohio Administrative Code 1301:7-7-58 Flammable Gases and Flammable Cryogenic Fluids
Go to chapter icon
Ohio Administrative Code 1301:7-7-59 Flammable Solids
Go to chapter icon
Ohio Administrative Code 1301:7-7-60 Highly Toxic and Toxic Materials
Go to chapter icon
Ohio Administrative Code 1301:7-7-61 Liquefied Petroleum Gases
Go to chapter icon
Ohio Administrative Code 1301:7-7-62 Organic Peroxides
Go to chapter icon
Ohio Administrative Code 1301:7-7-63 Oxidizers, Oxidizing Gases and Oxidizing Cryogenic Fluids
Go to chapter icon
Ohio Administrative Code 1301:7-7-64 Pyrophoric Materials
Go to chapter icon
Ohio Administrative Code 1301:7-7-65 Pyroxylin (Cellulose Nitrate) Plastics
Go to chapter icon
Ohio Administrative Code 1301:7-7-66 Unstable (Reactive) Materials
Go to chapter icon
Ohio Administrative Code 1301:7-7-67 Water-Reactive Solids and Liquids
Go to chapter icon
Chapter 68 Through 79 Reserved
Go to chapter icon
Ohio Administrative Code 1301:7-7-80 Referenced Standards
Go to chapter icon
Part VII Appendices
Appendix A Board of Appeals
Appendix B Fire-Flow Requirements for Buildings
Appendix C Fire Hydrant Locations and Distribution
Appendix D Fire Apparatus Access Roads
Appendix E Hazard Categories
Appendix F Hazard Ranking
Appendix G Cryogenic Fluids—Weight and Volume Equivalents
Appendix H Hazardous Materials Management Plan (HMMP) and Hazardous Materials Inventory Statement (HMIS) Instructions
Appendix I Fire Protection Systems—Noncompliant Conditions
Appendix J Building Information Sign
Appendix K Construction Requirements Forexisting Ambulatory Care Facilities
Go to chapter icon
Appendix L Requirements for Fire Fighter Air Replenishment Systems
Appendix M High-Rise Buildings—Retroactiveautomatic Sprinkler Requirement
Go to chapter icon
Appendix N Indoor Trade Shows and Exhibitions