Heads up: There are no amended sections in this chapter.

Chapter 15 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

1501.1 General

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the codes and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and the title. The application of the referenced standards shall be as specified in Section 102.5 of the building code.

1501.2 Referenced Codes

AMENDMENT
This section has been amended at the state or city level.
When indicated in the OPC, the following codes refer to provisions in the listed chapters of the Administrative Code:

REFERENCED CODE OHIO ADMINISTRATIVE CODE CHAPTERS
Building Code 4101:1-1 to 4101:1-35
Fire Code 1301:7-1 to 1301:7-7
Mechanical Code 4101:2-1 to 4101:2-15
Ohio Boiler and Pressure Vessel Rules 4101:4-1 to 4101:4-10

1501.3 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

AHRI Air-Conditioning, Heating, & Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
 
Standard
reference
number
Title Referenced
in code
section number
1010—02 Self- contained, Mechanically Refrigerated Drinking-Water Coolers

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
 
Standard
reference
number
Title Referenced
in code
section number
A118.10—14 Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set
Ceramic Tile and Dimension Stone Installation
Z4.3—95 (R2005) Minimum Requirements for Nonsewered Waste-disposal Systems
(Standard is developed by the Portable Sanitation Association International-PSAI)
Z21.22—15 Relief Valves for Hot Water Supply Systems with Addenda Z21.22a—2000 (R2003) and
Z21.22b—2001 (R2003)

API American Petroleum Institute
1220 L Street NW
Washington, DC 20005-4070
 
Standard
reference
number
Title Referenced
in code
section number
12D—2008 Specification for Field Welded Tanks for Storage of Production Liquids, effective April 1, 2009
12F—2008 Specification for Shop Welded Tanks for Storage of Production Liquids, effective April 1 2009

<
ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
A112.1.2—2012 Air Gaps in Plumbing Systems
A112.1.3—2000
(R2015)
Air Gap Fittings for Use with Plumbing Fixtures,
Appliances and Appurtenances
A112.3.1—2007 (R2014) Stainless Steel Drainage Systems for Sanitary, DWV, Storm and
Vacuum Applications Above and Below Ground
ASME A112.3.4—2013/
CSA B45.9—2013
Macerating Toilet Systems and Related Components
A112.4.1—2009(R2014) Water Heater Relief Valve Drain Tubes
A112.4.2—2015 Water Closet Personal Hygiene Devices
A112.4.3—1999 (R2015) Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System
A112.4.14—2004 (R2010) Manually Operated, Quarter-Turn Shutoff Valves for Use in Plumbing Systems
A112.6.1M—1997 (R2012) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use
A112.6.2—2000 (R2010) Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks
A112.6.3—2016 Floor and Trench Drains
A112.6.4—2003 (R2012) Roof, Deck, and Balcony Drains
A112.6.7—2010(R2015) Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks
A112.6.9—2005 (R2015) Siphonic Roof Drains
A112.14.1—2003(R2012) Backwater Valves
A112.14.3—2000(R2014) Grease Interceptors
A112.14.4—2001
(R2012)
Grease Removal Devices
A112.14.6—2010 (R2015) FOG (Fats, Oils and Greases) Disposal Systems
A112.18.1—2012/
CSA B125.1—2012
Plumbing Supply Fittings
A112.18.2—2015/CSA B125.2—2015 Plumbing Waste Fittings
A112.18.3—2002
(R2012)
Performance Requirements for Backflow Protection Devices and Systems in
Plumbing Fixture Fittings
A112.18.6/
CSA B125.6—2009(R2014)
Flexible Water Connectors
Al12.18.7-1999 (R2004) Deck mounted Bath/Shower Transfer Valves with Integral Backflow Protection
A112.18.9—2011 Protectors/Insulators for Exposed Waste and Supplies on Accessible Fixtures
A112.19.1/—2013
CSA B45.2—2013
Enameled Cast Iron and Enameled Steel Plumbing Fixtures
A112.19.2—2013/
CSA B45.1—13
Ceramic Plumbing Fixtures
A112.19.3—2008/
CSA B45.4—08(R2013)
Stainless Steel Plumbing Fixtures
A112.19.5/—2011
CSA B45.15—2011
Flush Valves and Spuds for Water-closets, Urinals, and Tanks
A112.19.7M—2012/
CSA B45.10—2012
Hydromassage Bathtub Systems
A112.19.12—2014 Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and
Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems
A112.19.14-2013 Six-Liter Water Closets Equipped with a Dual Flushing Device
A112.19.15—2012 Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors
A112.19.19—2006 Vitreous China Nonwater Urinals
A112.21.3-1985(R2007) Hydrants for Utility and Maintenance Use
A112.36.2M—1991
(R2012)
Cleanouts
ASSE 1016/
ASME A112.1016/
CSA B125.16-2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
B1.20.1—2013 Pipe Threads, General Purpose (inch)
B16.3—2011 Malleable Iron Threaded Fittings Classes 150 and 300
B16.4—2011 Gray Iron Threaded Fittings Classes 125 and 250
B16.9—2012 Factory-made Wrought Steel Buttwelding Fittings
B16.11—2011 Forged Fittings, Socket-welding and Threaded
B16.12—2009(R2014) Cast-iron Threaded Drainage Fittings
B16.15—2013 Cast Bronze Threaded Fittings
B16.18—2012 Cast Copper Alloy Solder Joint Pressure Fittings
B16.22—2013 Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
B16.23—2011 Cast Copper Alloy Solder Joint Drainage Fittings DWV
B16.26—2013 Cast Copper Alloy Fittings for Flared Copper Tubes
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns
B16.29— 2012 Wrought Copper and Wrought Copper Alloy Solder
Joint Drainage Fittings (DWV)
B16.34—2013 Valves Flanged, Threaded and Welding End
B16.51—2013 Copper and Copper Alloy Press-Connect Pressure Fittings
BPVC Section
IX-the edition referenced
in rule 4101:4-3-01 of the Administrative Code
Welding and Brazing Qualifications

ASPE American Society of Plumbing Engineers
8614 Catalpa Avenue, Suite 1007
Chicago, IL 60656-1116
 
Standard
reference
number
Title Referenced
in code
section number
45—2013 Siphonic Roof Drainage Systems

ASSE American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake, OH 44145
 
Standard
reference
number
Title Referenced
in code
section number
1001—2008 Performance Requirements for Atmospheric Type Vacuum Breakers
1002—2015 Performance Requirements for Antisiphon Fill Valves (Ballcocks) for
Gravity Water Closet Flush Tanks
1003—2009 Performance Requirements for Water Pressure Reducing Valves
1004—2008 Performance Requirements for Backflow Prevention Requirements for
Commercial Dishwashing Machines
1005—1999 Performance Requirements for Water Heater Drain Valves
1008—2006 Performance Requirements for Plumbing Aspects of Food Waste Disposer Units
1010—2004 Performance Requirements for Water Hammer Arresters
1011—2004 Performance Requirements for Hose Connection Vacuum Breakers
1012—2009 Performance Requirements for Backflow Preventers with Intermediate
Atmospheric Vent
1013—2011 Performance Requirements for Reduced Pressure Principle Backflow
Preventers and Reduced Pressure Principle Fire Protection
Backflow Preventers
1015—2011 Performance Requirements for Double Check Backflow Prevention
Assemblies and Double Check Fire Protection Backflow Prevention Assemblies
ASSE 1016/
ASME A112.1016/
CSA B125.16—2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
1017—2010 Performance Requirements for Temperature Actuated Mixing Valves for
Hot Water Distribution Systems
1018—2010 Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied
1019—2011 Performance Requirements for Vacuum Breaker Wall Hydrants,
Freeze Resistant, Automatic Draining Type
1020—2004 Performance Requirements for Pressure Vacuum Breaker Assembly
1022—2003 Performance Requirements for Backflow Preventer for Beverage
Dispensing Equipment
1024—2004 Performance Requirements for Dual Check Valve Type Backflow Preventers
(for Residential Supply Service or Individual Outlets)
1035—2008 Performance Requirements for Laboratory Faucet Backflow Preventers
1037—2015 Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures
1044—2015 Performance Requirements for Trap Seal Primer Devices Drainage Types and
Electronic Design Types
1047—2011 Performance Requirements for Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies
1048—2011 Performance Requirements for Double Check Detector Fire Protection
Backflow Prevention Assemblies
1049—2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for
Chemical Waste Systems
1050—2009 Performance Requirements for Stack Air Admittance Valves for Sanitary Drainage Systems
1051—2009 Performance Requirements for Individual and Branch Type Air Admittance Valves for
Sanitary Drainage Systems-fixture and Branch Devices
1052—2016 Performance Requirements for Hose Connection Backflow Preventers
1055—2009 Performance Requirements for Chemical Dispensing Systems
1056—2013 Performance Requirements for Spill Resistant Vacuum Breaker
1060—2006 Performance Requirements for Outdoor Enclosures for Fluid Conveying Components
1061—2015 Performance Requirements for Removable and Nonremovable Push Fit Fittings
1062—2006 Performance Requirements for Temperature Actuated, Flow Reduction Valves to
Individual Supply Fittings
1066—2009 Performance Requirements for Individual Pressure Balancing In-line Valves for
Individual Fixture Fittings
1069—2005 Performance Requirements for Automatic Temperature Control Mixing Valves
1070—2015 Performance Requirements for Water-temperature Limiting Devices
1072—2007 Performance Requirements for Barrier Type Floor Drain Tap Seal Protection Devices
1079—2012 Performance Requirements for Dielectric Pipe Unions
5013—2015 Performance Requirements for Testing Reduced Pressure Principle Backflow
Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)
5015—2015 Performance Requirements for Testing Double Check Valve Backflow Prevention
Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF)
5020—2015 Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA)
5047—2015 Performance Requirements for Testing Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies (RPDA)
5048—2015 Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)
5052—2015 Performance Requirements for Testing Hose Connection Backflow Preventers
5056—2015 Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB)

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
 
Standard
reference
number
Title Referenced
in code
section number
A53/A53M—12 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated
Welded and Seamless
A74—16 Specification for Cast-iron Soil Pipe and Fittings
A312/A312M—16 Specification for Seamless, Welded, And Heavily Cold Worked Austenitic
Stainless Steel Pipes
A733—15 Specification for Welded and Seamless Carbon Steel and Austenitic
Stainless Steel Pipe Nipples
A778—16 Specification for Welded Unannealed Austenitic Stainless Steel
Tubular Products
A888—15 Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste, and Vent Piping Application
B32—08(2014) Specification for Solder Metal
B42—15α Specification for Seamless Copper Pipe, Standard Sizes
B43—15 Specification for Seamless Red Brass Pipe, Standard Sizes
B75—11 Specification for Seamless Copper Tube
B88—14 Specification for Seamless Copper Water Tube
B152/B152M—13 Specification for Copper Sheet, Strip Plate and Rolled Bar
B251—10 Specification for General Requirements for Wrought Seamless Copper
and Copper-alloy Tube
B302—12 Specification for Threadless Copper Pipe, Standard Sizes
B306—13 Specification for Copper Drainage Tube (DWV)
B447—12a Specification for Welded Copper Tube
B687—99(2016) Specification for Brass, Copper and Chromium-plated Pipe Nipples
B813—16 Specification for Liquid and Paste Fluxes for Soldering of Copper and
Copper Alloy Tube
B828—16 Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
C4—04(2014) Specification for Clay Drain Tile and Perforated Clay Drain Tile
C14—15α Specification for Nonreinforced Concrete Sewer, Storm Drain and Culvert Pipe
C76—15α Specification for Reinforced Concrete Culvert, Storm Drain and Sewer Pipe
C425—04(2013) Specification for Compression Joints for Vitrified Clay Pipe and Fittings
C443—12 Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets
C564—14 Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings
C700—13 Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and
Perforated
C1053—00 (2015) Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and
Vent (DWV) Applications
C1173—10(2014) Specification for Flexible Transition Couplings for Underground Piping System
C1277—13 Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings
C1440—08 (2013) Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain,
Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems
C1460—12 Specification for Shielded Transition Couplings for Use with Dissimilar DWV
Pipe and Fittings Above Ground
C1461—08 (2013) Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE)
Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing
Systems for Above and Below Ground Use
C1540—15 Specification for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings
C1563—13 Standard Test Method for Gaskets for Use in Connection with Hub and Spigot
Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications
D1253—14 Standard Test Method For Residual Chlorine in Water
D1527—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80
D1785—15 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe, Schedules 40, 80 and 120
D2235—04(2011) Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
D2239—12a Specification for Polyethylene (PE) Plastic Pipe (SIDR-PR) Based on
Controlled Inside Diameter
D2241—15 Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series)
D2282—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)
D2464—15 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings,
Schedule 80
D2466—15 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
D2467—15 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
D2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings,
Schedule 40
D2564—12 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC)
Plastic Piping Systems
D2609—15 Specification for Plastic Insert Fittings for Polyethylene (PE) Plastic Pipe
D2657—15 Practice for Heat Fusion- joining of Polyolefin Pipe and Fitting Waste,
and Vent Pipe and Fittings
D2661—14 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40
Plastic Drain, Waste, and Vent Pipe and Fittings
D2665—14 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste,
and Vent Pipe and Fittings
D2672—14 Specification for Joints for IPS PVC Pipe Using Solvent Cement
D2683—14 Standard Specification for Socket-type Polyethylene fittings for Outside
Diameter-controlled Polyethylene Pipe and Tubing
D2729—11 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings
D2737—2012a Specification for Polyethylene (PE) Plastic Tubing
D2751—05 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe
and Fittings
D2846/D2846M—14 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and
Cold Water Distribution Systems
D2855—15 Standard Practice for Making Solvent-cemented Joints with
Poly (Vinyl Chloride) (PVC) Pipe and Fittings
D2949—10 Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC)
Plastic Drain, Waste, and Vent Pipe and Fittings
D3034—15 Specification for Type PSM Poly (Vinyl Chloride) (PVC)
Sewer Pipe and Fittings
D3035—15 Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on
Controlled Outside Diameter
D3139—98(2011) Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals
D3212—07 (2013) Specification for Joints for Drain and Sewer Plastic Pipes Using
Flexible Elastomeric Seals
D3261—15 Specification for Butt Heat Fusion Polyethylene (PE) Plastic fittings
for Polyethylene (PE) Plastic Pipe and Tubing
D3311—11 (2016) Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns
D4068—15 Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed
Water-containment Membrane
D4551—12 Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed
Water-containment Membrane
E2727—10el Standard Practice for the Assessment of Rainwater Quality
F405—13 Specification for Corrugated Polyethylene (PE) Pipe and Fittings
F409—12 Specification for Thermoplastic Accessible and Replaceable Plastic Tube
and Tubular Fittings
F437—15 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 80
F438—15 Specification for Socket- type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 40
F439—13 Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
Schedule 80
F441/F441M—15 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,
Schedules 40 and 80
F442/F442M—13el Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe (SDR-PR)
F477—14 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
F493—14 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe and Fittings
F628—12el Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic
Drain, Waste, and Vent Pipe with a Cellular Core
F656—15 Specification for Primers for Use in Solvent Cement Joints of
Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings
F714—2013 Specification for Polyethylene (PE) Plastic Pipe (SDR-PR) Based on Outside Diameter
F876—15α Specification for Cross-linked Polyethylene (PEX) Tubing
F877—2011a Specification for Cross-linked Polyethylene (PEX) Plastic Hot and
Cold Water Distribution Systems
F891—10 Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe
with a Cellular Core
F1055—15 Standard Specification for Electrofusion Type Polyethylene Fittings for
Outside Diameter Controlled Polyethylene and Crosslinked Polyethylene Pipe and Tubing
F1281—11 Specification for Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene
(PEX-AL-PEX) Pressure Pipe
F1282—10 Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure Pipe
F1412—16 Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage
F1476—13 Standard Specification for Performance of Gasketed Mechanical Couplings for
Use in Piping Applications
F1488—14 Specification for Coextruded Composite Pipe
F1548—01(2012) Standard Specification for the Performance of Fittings for Use with
Gasketed Mechanical Couplings Used in Piping Applications
F1673—10 Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems
F1807—15 Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of
Raised Temperature (PE-RT) Tubing
F1866—13 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and
DWV Fabricated Fittings
F1960—15 Specification for Cold Expansion Fittings with PEX Reinforcing Rings for use with
Cross-linked Polyethylene (PEX) Tubing
F1970—12el Special Engineered Fittings, Appurtenances or Valves for use in Poly (Vinyl Chloride) (PVC)
OR Chlorinated Poly (Vinyl Chloride) (CPVC) Systems
F1974—15 Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite
Pressure Pipe
F1986—01(2011) Specification for Multilayer Pipe, Type 2, Compression Fittings and
Compression Joints for Hot and Cold Drinking Water Systems
F2080—15α Specifications for Cold-expansion Fittings with Metal Compression-sleeves for
Cross-linked Polyethylene (PEX) Pipe
F2098—15 Standard specification for Stainless Steel Clamps for Securing SDR9 Cross-linked
Polyethylene (PEX) Tubing to Metal and Plastic Insert Fittings
F2159—14 Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for SDR9 Cross-linked
Polyethylene (PEX) Tubing and SDR9 Polyethylene of Raised Temperature (PE-RT) Tubing
F2262—09 Specification for Cross-linked Polyethylene/Aluminum/
Cross-linked Polyethylene Tubing OD Controlled SDR9
F2306/F2306M—14el 12'' to 60'' Annular Corrugated Profile-wall Polyethylene (PE) Pipe and Fittings for
Gravity Flow Storm Sewer and Subsurface Drainage Applications
F2389—15 Specification for Pressure-rated Polypropylene (PP) Piping Systems
F2434—14 Standard Specification for Plastic Insert Fittings Utilizing a
Copper Crimp Ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and SDR9
Cross-linked Polyethylene/Aluminum/ Cross-linked Polyethylene (PEX AL-PEX) Tubing
F2735—09 Standard Specification for Plastic Insert Fittings for SDR9 Cross-linked Polyethylene (PEX)
and Polyethylene of Raised Temperature (PE-RT) Tubing
F2769—14 Polyethylene or Raised Temperature (PE-RT) Plastic Hot and
Cold Water Tubing and Distribution Systems
F2831—12 Standard Practice for Internal Non Structural Epoxy Barrier Coating Material Used
In Rehabilitation of Metallic Pressurized Piping Systems
F2855—12 Specification Poly (Vinyl Chloride)/Aluminum/Poly (Vinyl Chloride) (CPVC/AL/CPVC)
Composite Pressure Tubing

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
 
Standard
reference
number
Title Referenced
in code
section number
A5.8M/A5.8—2011 Specifications for Filler Metals for Brazing and Braze Welding

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
 
Standard
reference
number
Title Referenced
in code
section number
C104/A21.4-13 Cement-mortar Lining for Ductile-iron Pipe and Fittings for Water
C110/A21.10—12 Ductile-iron and Gray- iron Fittings
C111/A21.11-12 Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings
C115/A21.15—11 Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
C151/A21.51—09 Ductile-iron Pipe, Centrifugally Cast for Water
C153—00/A21.53—11 Ductile- iron Compact Fittings for Water Service
C500—09 Standard for Metal-Seated Gate Valves for Water Supply Service
C504—15 Standard for Rubber-Seated Butterfly Valves
C507—15 Standard for Ball Valves, 6 In. Through 60 In
C510—07 Double Check Valve Backflow Prevention Assembly
C511—07 Reduced-pressure Principle Backflow Prevention Assembly
C651—14 Disinfecting Water Mains
C652—11 Disinfection of Water-storage Facilities
C901—08 Polyethylene (PE) Pressure Pipe and Tubing 1/2 inch (13 mm)
Through 3 inch (76 mm) for Water Service
C904—16 Cross-linked Polyethylene (PEX) Pressure Pipe 1/2 inch (13 mm)
Through 3 inch (76 mm) for Water Service
D100—11 Standard for Welded Carbon Steel Tanks for Water Storage
D115—06 Standard for Tendon Prestressed-Concrete Water Tanks
D120—09 Standard for Thermosetting Fiberglass-Reinforced Plastic Tanks

CISPI Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
 
Standard
reference
number
Title Referenced
in code
section number
301—12 Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
310—12 Specification for Coupling for Use in Connection with Hubless Cast-iron
Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications

CSA CSA Group
8501 East Pleasant Valley
Cleveland, OH 44131-5516
 
Standard
reference
number
Title Referenced
in code
section number
A257.1M—2012 Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.2M—2012 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
A257.3M—2012 Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and
Fittings Using Rubber Gaskets
ASME A112.18.1—2012/
CSA B125.1—2012
Plumbing Supply Fittings
ASME A112.18.2—2015/CSA B125.2—2015 Plumbing Waste Fittings
ASME A112.19.2—2013/
B45.1—2013
Ceramic Plumbing Fixtures
ASME A112.19.1—2013/
CSA B45.2—2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures
ASME A112.19.3—2008/
CSA B45.4—08 (R2013)
Stainless-steel Plumbing Fixtures
ASME A112.19.5—2011/
CSA B45.15— 2011
Flush Valves and Spuds for Water Closets, Urinals and Tanks
ASME A112.19.7—2012/
CSA B45.10—2012
Hydromassage Bathtub Systems
CSA B45.5—11 (R2016)/
IAPMO Z124-2011 (R2016)
Plastic Plumbing Fixtures
ASME A112.3.4—2013/
CSA B45.9—2013
Macerating Systems and Related Components
ASSE 1016/
ASME A112.1016/
CSA B125.16—2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
B64.1.1—11 (2016) Vacuum Breakers, Atmospheric Type (AVB)
B64.1.2—11 (2016) Pressure Vacuum Breakers, (PVB)
B64.1.3—11 (2016) Spill Resistant Pressure Vacuum Breakers (SRPVB)
B64.2—11 (2016) Vacuum Breakers, Hose Connection Type (HCVB)
B64.2.1—11 (2016) Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature
B64.2.1.1—11 (2016) Hose Connection Dual Check Vacuum Breakers, (HCDVB)
B64.2.2—11 (2016) Vacuum Breakers, Hose Connection Type (HCVB) with
Automatic Draining Feature
B64.3—11 (2016) Backflow Preventers, Dual Check Valve Type with
Atmospheric Port (DCAP)
B64.4—11 (2016) Backflow Preventers, Reduced Pressure Principle Type (RP)
B64.4.1—11 (2016) Reduced Pressure Principle for Fire Sprinklers (RPF)
B64.5—11 (2016) Double Check Backflow Preventers (DCVA)
B64.5.1—11 (2016) Double Check Valve Backflow Preventer for Fire Systems (DCVAF)
B64.6—11 (2016) Dual Check Backflow PreventersValve (DuC)
B64.7—11 (2016) Laboratory Faucet Vacuum Breakers (LFVB)
B64.10—11 (2016) Manual for the Selection and Installation of Backflow Prevention Devices
B64.10.1—11 (2016) Maintenance and Field Testing of Backflow Preventers
B79—08(R2013) Commercial and Residential Drains, and Cleanouts
B125.3—2012 Plumbing Fittings
B137.1— 13 Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services
B137.2—13 Polyvinylchloride PVC Injection-moulded Gasketed Fittings for Pressure Applications
B137.3—13 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
B137.5—13 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
B137.6—13 CPVC Pipe, Tubing and Fittings for Hot and
Cold Water Distribution Systems
B137.9—13 Polyethylene/Aluminum/
Polyethylene Composite Pressure Pipe Systems
B137.10—13 Cross- linked Polyethylene/Aluminum/
Polyethylene Composite Pressure Pipe Systems
B137.11—13 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
B181.1—15 Acrylonitrile-butadiene- styrene ABS Drain,
Waste and Vent Pipe and Pipe Fittings
B181.2—15 Polyvinylchloride PVC and chlorinated polyvinylchloride (CPVC)
Drain, Waste, and Vent Pipe and Pipe Fittings
B181.3—15 Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems
B182.1—15 Plastic Drain and Sewer Pipe and Pipe Fittings
B182.2—15 PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings
B182.4—15 Profile Polyvinylchloride PVC Sewer Pipe and Fittings
B182.6—15 Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-proof Sewer Applications
B182.8—15 Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings
B356—10 (R2015) Water Pressure Reducing Valves for Domestic Water Systems
B483.1—14 Drinking Water Treatment Units
B481.1—12 Testing and Rating of Grease interceptors Using Lard
B481.3—12 Sizing, Selection, Location and Installation of Grease Interceptors
B602—16 Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe

FEMA Federal Emergency Management Agency
Federal Center Plaza 500 C Street S.W.
Washington, DC 20472
 
Standard
reference
number
Title Referenced
in code
section number
44 CPR Parts 59-77 (2002) National Flood Insurance Program

IAPMO IAPMO Group
4755 E. Philadelphia
Ontario, CA 91761
 
Standard
reference
number
Title Referenced
in code
section number
Z1001-2014 Prefabricated Gravity Grease Interceptors
CSA B45.5—11 (R2016)/
IAPMO Z124-2011 (R2016)
Plastic Plumbing Fixtures

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
A117.1—2009 Accessible and Usable Buildings and Facilities
IFGC—15 International Fuel Gas Code®

ISEA International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington, VA 22209
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/ISEA Z358.1—2014 Emergency Eyewash and Shower Equipment

MSS Manufacturers Standardization Society Of the Valve and Fittings Industry, Inc.
127 Park St. NE
Vienna, VA 22180-4602
 
Standard
reference
number
Title Referenced
in code
section number
SP-67—2011 Butterfly Valves
SP-70—2011 Gray Iron Gate Valves, Flanged and Threaded Ends
SP-71—2011 Gray Iron Swing Check Valves, Flanged and Threaded Ends
SP-72—2010α Ball Valves with Flanged or Butt-Welding Ends for General Service
SP-78—2011 Cast Iron Plug Valves, Flanged and Threaded Ends
SP-80—2013 Bronze Gate, Globe, Angle and Check Valves
SP-110—2010 Ball Valves, Threaded, Socket Welded, Solder Joint, Grooved and Flared Ends

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
 
Standard
reference
number
Title Referenced
in code
section number
70—17 National Electrical Code
99—15 Health Care Facilities Code

NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
 
Standard
reference
number
Title Referenced
in code
section number
3—2012 Commercial Warewashing Equipment
14—2014 Plastic Piping System Components and Related Materials
18—2012 Manual Food and Beverage Dispensing Equipment
42—2015 Drinking Water Treatment Units-Aesthetic Effects
44—2015 Residential Cation Exchange Water Softeners
50—2015 Equipment for Swimming Pools, Spas, Hot Tubs and other Recreational Facilities
53—2015 Drinking Water Treatment Units—Health Effects
58—2015 Reverse Osmosis Drinking Water Treatment Systems
61—2015 Drinking Water System Components—Health Effects
62—2015 Drinking Water Distillation Systems
350—2014 Onsite Residential and Commercial Water Reuse Treatment Systems
359—2011 Valves for Crosslinked Polyethylene (PEX) Water Distribution Tubing Systems
372—2016 Drinking Water Systems Components—Lead Content

PDI Plumbing and Drainage Institute
800 Turnpike Street, Suite 300
North Andover, MA 01845
 
Standard
reference
number
Title Referenced
in code
section number
PDI G101 2015 Testing and Rating Procedure for Grease Interceptors with
Appendix of Sizing and Installation Data
PDI G102-2009 Testing and Certification for Grease Interceptors with Fog Sensing and Alarm Devices

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062- 2096
 
Standard
reference
number
Title Referenced
in code
section number
399—2008 Drinking-Water Coolers—with revisions through January 14, 2011
430—2015 Waste Disposers
508—99 Industrial Control Equipment—with revisions through March 2013
1795—2009 Hydromassage Bathtubs including revisions through August 23, 2011
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING