Chapter 15 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.

1501.1 General

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the codes and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and the title. The application of the referenced standards shall be as specified in Section 102.5 of the building code.

1501.2 Referenced Codes

AMENDMENT
This section has been amended at the state or city level.
When indicated in the OMC, the following codes refer to provisions in the listed chapters of the Administrative Code:

REFERENCED CODE OHIO ADMINISTRATIVE CODE CHAPTERS
Building Code 4101:1-1 to 4101:1-35
Fire Code 1301:7-1 to 1301:7-7
Ohio Boiler and Pressure Vessel Rules 4101:4-1 to 4101:4-10
Plumbing Code 4101:3-1 to 4101:3-15

1501.3 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
 
Standard
reference
number
Title Referenced
in code
section number
Manual D—2014 Residential Duct Systems
183—2007
(reaffirmed 2011)
Peak Cooling and Heating Load Calculations in Buildings Except Low-rise Residential Buildings

AHRI Air-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
 
Standard
reference
number
Title Referenced
in code
section number
700—2016
with Addendum 1
Purity Specifications for Fluorocarbon and Other Refrigerants

AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
 
Standard
reference
number
Title Referenced
in code
section number
230-CD1 Laboratory Methods of Testing Air Circulating Fans for Rating and Certification
550—15 Test Method for High Velocity Wind Driven Rain Resistant Louvers


ANSI American National Standards Institute
11 West 42nd Street
New York, NY 10036
 
Standard
reference
number
Title Referenced
in code
section number
Z21.8—1994 (R2012) Installation of Domestic Gas Conversion Burners

ASHRAE ASHRAE
1791 Tullie Circle, NE
Atlanta, GA 30329
 
Standard
reference
number
Title Referenced
in code
section number
Handbook—2013 ASHRAE Fundamentals Handbook
15—2013 Safety Standard for Refrigeration Systems
34—2013 Designation and Safety Classification of Refrigerants
62.1—2016 Ventilation for Acceptable Indoor Air Quality
62.2-2016 Ventilation and Acceptable indoor Air Quality in Low-Rise Residential Buildings
170—2013 Ventilation of Health Care Facilities
180—2012 Standard Practice for Inspection and Maintenance of Commercial
Building HVAC Systems

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—2013 Pipe Threads, General Purpose (Inch)
B16.3—2011 Malleable Iron Threaded Fittings, Classes 150 & 300
B16.5—2013 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24
B16.9—2012 Factory Made Wrought Steel Buttwelding Fittings
B16.11—2011 Forged Fittings, Socket-welding and Threaded
B16.15—2013 Cast Bronze Threaded Fittings
B16.18—2012 Cast Copper Alloy Solder Joint Pressure Fittings
B16.22—2013 Wrought Copper and Copper Alloy Solder Joint Pressure Fittings
B16.24—2011 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900,
1500 and 2500
B16.26—2013 Cast Copper Alloy Fittings for Flared Copper Tubes
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns
B16.51—2013 Copper and Copper Alloy Press-Connect Pressure Fittings
B31.5—2016 Refrigeration Piping and Heat Transfer Components
B31.9—2014 Building Services Piping
BPVC—the edition
referenced in
rule 4101:4-3-01 of the Administrative Code
ASME Boiler & Pressure Vessel Code
CSD-1—the edition
referenced in
rule 4101:4-3-01 of
the Administrative Code
Controls and Safety Devices for Automatically Fired Boilers

ASSE American Society of Safety Engineers
1800 East Oakton Street
Des Plaines, IL 60018
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/ASSE Z359.1-2007 Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components,
Part of the Fall Protection Code

ASSE American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
 
Standard
reference
number
Title Referenced
in code
section number
1017—2010 Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
 
Standard
reference
number
Title Referenced
in code
section number
A53/A53M—12 Specification for Pipe, Steel, Black and Hot-dipped,
Zinc-coated Welded and Seamless
A106/A106M—14 Specification for Seamless Carbon Steel Pipe for High-Temperature Service
A126—14 Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings
A234/A234M—15 Standard Specification for Piping Fittings of Wrought Carbon Steel And Alloy Steel
For Moderate and High Temperature Service
A254—A254-12 Specification for Copper Brazed Steel Tubing
A395/A395M-2014 Standard Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at
Elevated Temperatures
A420/A420M—16 Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel
for Low-Temperature Service
A536-14 Standard Specification for Ductile Iron Castings
A539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and
Fuel Oil Lines
B32—14 Specification for Solder Metal
B42—15 Specification for Seamless Copper Pipe, Standard Sizes
B43—15 Specification for Seamless Red Brass Pipe, Standard Sizes
B68—11 Specification for Seamless Copper Tube, Bright Annealed
B75—11 Specification for Seamless Copper Tube
B88—14 Specification for Seamless Copper Water Tube
B135—10 Specification for Seamless Brass Tube
B251—10 Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
B280—16 Specification for Seamless Copper Tube for Air Conditioning and
Refrigeration Field Service
B302—12 Specification for Threadless Copper Pipe, Standard Sizes
B813—16 Specification for Liquid and Paste Fluxes for Soldering of Copper and
Copper Alloy Tube
C315—07(2011) Specification for Clay Flue Liners and Chimney Pots
C411—11 Test Method for Hot-surface Performance of High-temperature Thermal Insulation
D56—16 Test Method for Flash Point by Tag Closed Tester
D93—16 Test Method for Flash Point of Pensky-Martens Closed Cup Tester
D1527—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe,
Schedules 40 and 80
D1693—15 Test Method for Environmental Stress-Cracking of Ethylene Plastics
D1785—15 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe,
Schedules 40, 80 and 120
D2235—04(2011) Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS)
Plastic Pipe and Fittings
D2241—15 Specification for Poly (Vinyl Chloride)(PVC)
Pressure-rated Pipe (SDR-Series)
D2282—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR)
D2412—11 Test Method for Determination of External Loading Characteristics of Plastic Pipe
by Parallel-plate Loading
D2464—15 Standard Specification for Threaded Poly(Vinyl Chloride) (PVC)
Plastic Pipe Fittings, Schedule 80
D2466—15 Specification for Poly (Vinyl Chloride)(PVC)
Plastic Pipe Fittings, Schedule 40
D2467—15 Specification for Poly (Vinyl Chloride)(PVC)
Plastic Pipe Fittings, Schedule 80
D2564—12 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems
D2657—15 Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings
D2683—14 Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled
Polyethylene Pipe and Tubing
D2737—12A Standard Specification for Polyethylene (PE) Plastic Tubing
D2846/D2846M—14 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and
Cold Water Distribution Systems
D2996—15 Specification for Filament-wound Fiberglass
(Glass Fiber Reinforced Thermosetting Resin) Pipe
D3035—2015 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on
Controlled Outside Diameter
D3261—15 Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for
Polyethylene (PE) Plastic Pipe and Tubing
D3278—1996(2011) Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus
D3309—96a(2002) Specification for Polybutylene (PB) Plastic Hot and
Cold Water Distribution Systems
E84—16 Test Method for Surface Burning Characteristics of Building Materials
E119—2016α Test Method for Fire Tests of Building Construction and Materials
E136—16 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C
E814—2013α Test Method for Fire Tests of Through-penetration Fire Stops
E1509—12 Specification for Room Heaters, Pellet Fuel-burning Type
E2231—15 Standard Practice For Specimen Preparation and Mounting of Pipe and
Duct Insulation Materials to Assess Surface Burning Characteristics
E2336—16 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems
F437—15 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
F438—15 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
F439—13 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
F441/F441M—15 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe,
Schedules 40 and 80
F442/F442M—13 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe (SDR-PR)
F493—14 Specification for Solvent Cements for Chlorinated Poly
(Vinyl Chloride) (CPVC) Plastic Pipe and Fittings
F714—13 Standard Specification for Polyethylene (PE) Plastic Pipe
(SDR-PR) based on Outside Diameter
F876—2015α Specification for Cross-linked Polyethylene (PEX) Tubing
F877—2011A Specification for Cross-linked Polyethylene (PEX) Plastic Hot and
Cold Water Distribution Systems
F1055—15 Specification for Electrofusion Type Polyethylene Fittings for
Outside Diameter Controlled Polyethylene and
Cross-linked Polyethylene Pipe and Tubing
F1281—11 Specification for Cross-linked Polyethylene/Aluminum/Crosslinked Polyethylene
(PEX-AL-PEX) Pressure Pipe
F1282—10 Standard Specification for Polyethylene/Aluminum/
Polyethylene (PE-AL-PE) Composite Pressure Pipe
F1476—07(2013) Specification for Performance of Gasketed Mechanical Couplings for Use in
Piping Applications
F1548—01(2012) Standard Specification for the Performance of Fittings for Use with
Gasketed Mechanical Couplings Used in Piping Applications
F1807—15 Standard Specification for Metal Insert Fittings Utilizing a Copper Crimp Ring for
SDR 9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polethylene of
Raised Temperature (PE-RT) Tubing
F1924—12 Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled
Polyethylene Gas Distribution Pipe and Tubing
F1960—15 Specification for Cold-Expansion Fittings with PEX Reinforcing Rings for Use with
Cross-linked Polyethylene (PEX) Tubing
F1974—09(2015) Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and
Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
F2080—15α Specification for Cold-Expansion Fittings with Metal Compression-Sleeves for
Cross-linked Polyethylene (PEX) Pipe
F2098—15 Standard Specification for Stainless Steel Clamps for SDR9 Cross-linked Polyethylene (PEX)
Tubing to Metal and Plastic Insert Fittings
F2159—14 Standard Specification for Plastic Insert Fittings Utilizing a Copper Crimp Ring for
SDR 9 Cross-linked Polyethylene (PEX) Tubing and SDR9 Polyethylene of
Raised Temperature (PE-RT) Tubing
F2389—15 Specification for Pressure-rated Polypropylene Piping Systems
F2434—14 Standard Specification for Metal Insert Fittings Utilizing a
Copper Crimp ring for SDR9 Cross-linked Polyethylene (PEX) Tubing and
SDR9 Cross-linked Polyethylene/Aluminum/
Cross-linked Polyethylene (PEX-AL-PEX) Tubing
F2623—14 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1
F2735—09(2016) Standard Specification for Plastic Insert Fittings for SDR 9 Cross-linked Polyethylene (PEX)
and Polyethylene of Raised Temperature (PE-RT) Tubing
F2769—14 Polyethylene of Raised Temperature (PE-RT) Plastic Hot- and Cold-water Tubing and
Distribution Systems
F2806—15 Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe
(Metric SDR-PR)

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
 
Standard
reference
number
Title Referenced
in code
section number
A5.8M/A5.8—2011 Specifications for Filler Metals for Brazing and Braze Welding

AWWA American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
 
Standard
reference
number
Title Referenced
in code
section number
C901—08 Polyethylene (PE) Pressure Pipe and
Tubing, 1/2 in. (13mm) through 3 in. (76mm) for Water Service
C110/A21.10—12 Standard for Ductile Iron & Gray Iron Fittings
C115/A21.15—11 Standard for Flanged Ductile-Iron Pipe with Ductile Iron or Grey-Iron Threaded Flanges
C151/A21.51—09 Standard for Ductile-Iron Pipe, Centrifugally Cast for Water
C153/A21.53—11 Standard for Ductile-Iron Compact Fittings for Water Service

CSA CSA Group
8501 East Pleasant Valley Road
Cleveland, OH 44131-5516
 
Standard
reference
number
Title Referenced
in code
section number
B137.2—13 Polyvinylchloride (PVC) Injection-moulded Gasketed Fittings for Pressure Applications
B137.3—13 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
B137.6—13 Chlorinated Polyvinylchloride (CPVC) Pipe, Tubing and Fittings for Hot- and
Cold-water Distribution Systems
B137.9—13 Polyethylene/Aluminum/Polyethylene (PE-AL-PE)
Composite Pressure-Pipe Systems
B137.10—13 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene (PEX-AL-PEX)
Composite Pressure-Pipe Systems
CSA C448 Series—13 Design and Installation of Earth Energy Systems—First Edition; Update 2: October 2009;
 CAN/CSA 2002 Consolidated Reprint 10/2009
CSA B137.1—13 Polyethylene (PE) Pipe, Tubing and Fittings for Cold Water Pressure Services
CSA B137.5—13 Cross-linked Polyethylene (PEX) Tubing Systems for Pressure Applications
CSA B137.11—13 Polypropylene (PP-R) Pipe and Fittings for Pressure Applications
ANSI CSA
America FC1—2014
Stationary Fuel Cell Power Systems

DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000
(2016)
Air Contaminants
29 CFR Part 1910.1025
(2016)
Toxic and Hazardous Substances


FS Federal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington, DC 20407
 
Standard
reference
number
Title Referenced
in code
section number
WW-P-325B (1976) Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and
Waste Applications)
  *Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325  

ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
IECC—12 International Energy Conservation Code®
IFGC—15 International Fuel Gas Code®


IIAR International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
 
Standard
reference
number
Title Referenced
in code
section number
2—2014 Standard for Safe Design of Closed-circuit Ammonia Refrigeration Systems

MSS Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
 
Standard
reference
number
Title Referenced
in code
section number
SP 58—2009 Pipe Hangers and Supports—Materials Design and Manufacture, Selection,
Application and Installation

NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
 
Standard
reference
number
Title Referenced
in code
section number
AH116—09 Fibrous Glass Duct Construction Standards

NBBI National Board of Boiler and Pressure Vessel Inspectors
1055 Crupper Avenue
Columbus, OH 43229-1183
 
Standard
reference
number
Title Referenced
in code
section number
NBIC—edition
referenced in
rule 4101:4-3-01 of the Administrative Code
National Board Inspection Code, Part 3

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
 
Standard
reference
number
Title Referenced
in code
section number
30-15 Flammable and Combustible Liquids Code
30A—15 Code for Motor Fuel-dispensing Facilities and Repair Garages
31—16 Standard for the Installation of Oil-burning Equipment
37—15 Standard for the Installation and Use of Stationary Combustion Engines and Gas Turbines
58—17 Liquefied Petroleum Gas Code
69—14 Standard on Explosion Prevention Systems
70—17 National Electrical Code
72—16 National Fire Alarm and Signaling Code
75-09 Protection of Information Technology Equipment
82—14 Standard on Incinerators and Waste and Linen Handling Systems and Equipment
85—the edition
referenced in
rule 4101:4-3-01 of the Administrative Code
Boiler and Combustion Systems Hazards Code
91—15 Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and
Noncombustible Particulate Solids
92—15 Standard for Smoke Control Systems
96—14 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations
211—16 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances
262—15 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for
Use in Air-handling Spaces
286—15 Standard Methods of Fire Tests for Evaluating Contribution of Wall and
Ceiling Interior Finish to Room Fire Growth
704—17 Standard System for Identification of the Hazards of Materials for
Emergency Response
853—15 Standard on Installation of Stationary Fuel Power Plants

NSF NSF International
789 Dixboro Road, P. O. Box 130140
Ann Arbor, MI 48113-0140
 
Standard
reference
number
Title Referenced
in code
section number
NSF 358-1-2014 Polyethylene Pipe and Fittings for Water Based Ground Source
"Geothermal" Heat Pump Systems

SMACNA Sheet Metal & Air-Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
 
Standard
reference
number
Title Referenced
in code
section number
SMACNA/ANSI—2005 HVAC Duct Construction Standards-Metal and
Flexible 3rd Edition (ANSI)
SMACNA—10 Fibrous Glass Duct Construction Standards

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096
 
Standard
reference
number
Title Referenced
in code
section number
17—2008 Vent or Chimney Connector Dampers for Oil-fired Appliances
with revisions Through January 2010
103—2010 Factory-built Chimneys, Residential Type and Building Heating Appliance
with revisions through July 2012
127—2011 Factory-built Fireplaces
174—04 Household Electric Storage Tank Water Heaters—with revisions through September 2012
180—2012 Liquid-level Indicating Gauges for Oil Burner Fuels and Other Combustible Liquids
181—13 Factory-made Air Ducts and Air Connectors—
with revisions through October 2008
181A—2013 Closure Systems for Use with Rigid Air Ducts and Air Connectors
181B—2013 Closure Systems for Use with Flexible Air Ducts and Air Connectors
197—10 Commercial Electric Cooking Appliances—with revisions through June 2011
207—2009 Refrigerant-containing Components and Accessories, Nonelectrical
263—2011 Standard for Fire Test of Building Construction and Materials
268—2016 Smoke Detectors for Fire Alarm Systems
268A—2008 Smoke Detectors for Duct Application—with revisions through September 2009
343—2008 Pumps for Oil-Burning Appliances—with revisions through June 2013
378—06 Draft Equipment—with revisions through January 2010
391—2010 Solid-fuel and Combination-fuel Central and Supplementary Furnaces
with revisions through March 2010
412—2011 Refrigeration Unit Coolers—with revisions through August 2012
471—2010 Commercial Refrigerators and Freezers—with revisions through December 2012
499—14 Electric Heating Appliances—with revisions through February 2013
508—99 Industrial Control Equipment—with revisions through March 2013
536—14 Flexible Metallic Hose—with revisions through June 2003
555—06 Fire Dampers—with revisions through May 2012
555C—14 Ceiling Dampers—with revisions through May 2010
555S—14 Smoke Dampers—with revisions through May 2012
586—2009 High-Efficiency, Particulate, Air Filter Units
641—2010 Type L Low-temperature Venting Systems—with revisions through May 2013
705—2004 Standard for Power Ventilators—with revisions through March 2012
710—2012 Exhaust Hoods for Commercial Cooking Equipment
710B—2011 Recirculating Systems
723—2008 Standard for Test for Surface Burning Characteristics of Building Materials
726—95 Oil-fired Boiler Assemblies—with revisions through April 2011
727—06 Oil-fired Central Furnace—with revisions through April 2010
729—03 Oil-fired Floor Furnaces—with revisions through August 2012
730—03 Oil-fired Wall Furnaces—with revisions through August 2012
731—95 Oil-fired Unit Heaters—with revisions through August 2012
732—95 Oil-fired Storage Tank Water Heaters—with revisions through April 2010
737—2011 Fireplace Stoves
762—2013 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances
791—06 Residential Incinerators—with revisions through April 2010
834—04 Heating, Water Supply and Power Boilers Electric—with revisions through January 2013
842—15 Valves for Flammable Fluids—with revisions through October 2012
858—14 Household Electric Ranges—with revisions through April 2012
867—2011 Electrostatic Air Cleaners—with revisions through February 2013
875—09 Electric Dry Bath Heater—with revisions through November 2011
896—93 Oil-burning Stoves—with revisions through August 2012
900—15 Air Filter Units—with revisions through February 2012
907—16 Fireplace Accessories—with revisions through April 2010
923—2013 Microwave Cooking Appliances
959—2010 Medium Heat Appliance Factory-built Chimneys
1046—2010 Grease Filters for Exhaust Ducts—with revisions through January 2012
1240—2012 Electric Commercial Clothes—Drying Equipment—with revisions through October 2012
1261—01 Electric Water Heaters for Pools and Tubs—with revisions through July 2012
1453—16 Electric Booster and Commercial Storage Tank Water Heaters
with revisions through July 2011
1479—15 Fire Tests of Through-penetration Firestops—
with revisions through October 2012
1482—2011 Solid-fuel Type Room Heaters
1618—15 Wall Protectors, Floor Protectors and Hearth Extensions—
with revisions through May 2013
1777—2015 Chimney Liners—with revisions through July 2009
1812—2013 Standard for Ducted Heat Recovery Ventilators
1815—2012 Standard for Nonducted Heat Recovery
1820—04 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—
with revisions through May 2013
1887—04 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—
with revisions through May 2013
1978—2010 Grease Ducts
1995—2015 Heating and Cooling Equipment
1996—2009 Electric Duct Heaters—with revisions through November 2011
2024—2014 Standard for Safety Optical-Fiber and Communications Cable Raceway—
with revisions through April 2011
2043—2013 Fire Test for Heat and Visible Smoke Release for Discrete Products and their
Accessories Installed in Air-handling Spaces
2085-10 Protected Above-Ground Tanks for Flammable and Combustible Liquids
2158—15 Electric Clothes Dryers—with revisions through March 2009
2158A—2013 Outline of Investigation for Clothes Dryer Transition Duct
2162—14 Outline of Investigation for Commercial Wood-fired Baking Ovens-Refractory Type
2200—2012 Stationery Engine Generator Assemblies—with revisions through June 2013
2221—2010 Tests of Fire Resistive Grease Duct Enclosure Assemblies
2518—16 Air Dispersion System Materials
2523—09 Solid Fuel-fired Hydronic Heating Appliances—with revisions through February 2013