Heads up: There are no amended sections in this chapter.

Chapter 15 Referenced Standards

AMENDMENT
This section has been amended at the state or city level.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.8.

ACCA Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington, VA 22206
Standard
reference
number
Title Referenced
in code
section number
Manual D—95 Residential Duct Systems 603.2
Manual J—02 Residential Load Calculations, Eighth Edition 312
Manual S—04 Residential Equipment Selection 312
183—2007 Peak Cooling and Heating Load Calculations in Buildings Except Low-Rise Residential Buildings 312.1



AHRI Air-Conditioning, Heating and Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
reference
number
Title Referenced
in code
section number
700—99 Purity Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3
AMCA Air Movement and Control Association International
30 West University Drive
Arlington Heights, IL 60004
Standard
reference
number
Title Referenced
in code
section number
230-15 Laboratory Methods of Testing Air Circulating Fans for Rating and Certification 931



ANSI American National Standards Institute
11 West 42nd Street
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
Z21.8—1994 (R2002) Installation of Domestic Gas Conversion Burners 919.1



ASHRAE American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329
Standard
reference
number
Title Referenced
in code
section number
ASHRAE—2005 ASHRAE Fundamentals Handbook—2005 603.2
15—2004 Safety Standard for Refrigeration Systems 1101.6, 1108.1
34—2004 Designation and Safety Classification of Refrigerants 202, 1102.2.1, 1103.1
62.1—2004 Ventilation for Acceptable Indoor Air Quality 403.3.2.3.2



ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—2006 Malleable Iron Threaded Fittings, Classes 150 & 300 Table 1202.5
B16.5—2003 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24— Table 1202.5
B16.9—2003 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—2005 Forged Fittings, Socket-welding and Threaded Table 1202.5
B16.15—2006 Cast Bronze Threaded Fittings Table 1202.5
B16.18—2001 (Reaffirmed 2005) Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—2001 (Reaffirmed 2005) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.23—2002 (Reaffirmed 2006) Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 1202.5
B16.24—2001 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500 and 2500 Table 1202.5
B16.26—2006 Cast Copper Alloy Fittings for Flared Copper Tubes Table 1202.5
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 1202.5
B16.29—2001 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings-DWV Table 1202.5
B16.51—2011 Copper and Copper Alloy Press-Connect Pressure Fittings Table 1202.5
B31.9—04 Building Services Piping 1201.3
BPVC—2004 Boiler & Pressure Vessel Code 1004.1, 1011.1
CSD-1—2004 Controls and Safety Devices for Automatically Fired Boilers 1004.1



ASSE American Society of Sanitary Engineering
901 Canterbury, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1017—03 Performance Requirements for Temperature Actuated Mixing Values for Hot Water Distribution Systems 1002.2.2



ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—06a Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless Table 1202.4, Table 1302.3
A 106/A106M—06a Specification for Seamless Carbon Steel Pipe for High-Temperature Service Table 1202.4, Table 1302.3
A 126—04 Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings Table 1202.5
A 254—97 (2002) Specification for Copper Brazed Steel Tubing Table 1202.4, Table 1302.3
A 420/A 420M—07 Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Low-Temperature Service Table 1202.5
A 539—99 Specification for Electric-Resistance-Welded Coiled Steel Tubing for Gas and Fuel Oil Lines Table 1302.3
B 32—04 Specification for Solder Metal 1203.3.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 43—98(2004) Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1, 1107.5.2, Table 1202.4, Table 1302.3
B 68—02 Specification for Seamless Copper Tube, Bright Annealed 513.13.1
B 75—02 Specification for Seamless Copper Tube Table 1202.4, Table 1302.3
B 88—03 Specification for Seamless Copper Water Tube 513.13.1, 1107.5.3, Table 1202.4, Table 1302.3
B 135—02 Specification for Seamless Brass Tube Table 1202.4, Table 1302.3
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube 513.13.1, Table 1202.4
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 513.13.1, 1107.4.3, Table 1302.3
B 302—02 Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4, Table 1302.3
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube 1203.3.3
C 315—07 Specification for Clay Flue Liners and Chimney Pots 801.16.1, Table 803.10.4
C 411—05 Test Method for Hot-surface Performance of High-temperature Thermal Insulation 604.3
D 56—05 Test Method for Flash Point by Tag Closed Tester 202
D 93—07 Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 1202.4
D 1693—07 Test Method for Environmental Stress-Cracking of Ethylene Plastics Table 1202.4
D 1785—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 1202.4
D 2235—04 Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings 1203.3.4
D 2241—05 Specification for Poly (Vinyl Chloride)(PVC) Pressure-rated Pipe (SDR-Series) Table 1202.4
D 2282—99(2005) Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 1202.4
D 2412—02 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-plate Loading 603.8.3
D 2447—03 Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter Table 1202.4
D 2466—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2467—06 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe Fittings, Schedule 80 Table 1202.5
D 2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2513—07a Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings Table 1202.4
D 2564—04e01 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 1203.3.4
D 2657—07 Standard Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings 1203.15.1
D 2683—04 Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled Polyethylene Pipe and Tubing Table 1202.4, 1203.15.1
D 2837—04e01 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for Thermoplastic Pipe Products Table 1202.4
D 2846/D 2846M—06 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems Table 1202.4, 1203.3.4
D 2996—01(2007)e01 Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting Resin) Pipe Table 1302.3
D 3035—06 Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside Diameter Table 1202.4
D 3278—96(2004)e01 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D 3261—03 Standard Specification for Butt Heat Fusion Polyethylene (PE) Plastic Fittings for Polyethylene (PE) Plastic Pipe and Tubing 1203.15.1
D 3309—96a(2002) Specification for Polybutylene (PB) Plastic Hot and Cold Water Distribution Systems Table 1202.4, 1203.10.1
D 3350—06 Specification for Polyethylene Plastics Pipe and Fittings Materials Table 1202.4
E 84—07 Test Method for Surface Burning Characteristics of Building Materials 202, 510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
E 119—07 Test Method for Fire Tests of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1, 607.2.1
E 136—04 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C 202
E 814—06 Test Method for Fire Tests of Through-penetration Fire Stops 506.3.10.2, 506.3.10.3
E 1509—04 Specification for Room Heaters, Pellet Fuel-burning Type 904.1
E 2231—04 Standard Practice For Specimen Preparation and Mounting of Pipe and Duct Insulation Materials to Assess Surface Burning Characteristics 604.3, 1204.1
E 2336-04 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems 506.3.6, 506.3.10.2
F 438—04 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 Table 1202.5
F 439—06 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 Table 1202.5
F 441/F 441M—02 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Table 1202.4
F 442/F 442M—99(2005) Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Table 1202.4
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings 1203.3.4
F 876—06 Specification for Crosslinked Polyethylene (PEX) Tubing Table 1202.4
F 877—07 Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold Water Distribution Systems Table 1202.4, Table 1202.5
F 1055—98(2006) Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter Controlled Polyethylene Pipe and Fittings Table 1202.4, 1203.15.2
F 1281—07 Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe Table 1202.4
F 1282—06 Standard Specification for Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure Pipe Table 1202.4
F 1476—(2006) Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications 1203.3.7
F 1924—05 Standard Specification for Plastic Mechanical Fittings for Use on Outside Diameter Controlled Polyethylene Gas Distribution Pipe and Tubing 1203.15.3
F 1974—04 Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe Table 1202.5
F 2389—06 Specification for Pressure-Rated Polypropylene Piping Systems Table 1202.4, Table 1202.5
F 2623—07 Standard Specification for Polyethylene of Raised Temperature (PE-RT) SDR 9 Tubing1 Table 1202.4



AWS American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
Standard
reference
number
Title Referenced
in code
section number
A5.8—2004 Specifications for Filler Metals for Brazing and Braze Welding 1203.3.1, 1303.3.1



AWWA American Water Work Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C110/A21.10—03 Standard for Ductile Iron & Gray Iron Fittings, 2 inches Through 48 inches for Water Table 1202.5
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile Iron or Grey-iron Threaded Flanges Table 1202.4
C151/A21.51—02 Standard for Ductile-Iron Pipe, Centrifugally Cast for Water Table 1202.4
C153/A21.53—00 Standard for Ductile-Iron Compact Fittings for Water Service Table 1202.5



CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
B137.9-M91 CAN/CSA Polyethylene/Aluminum/Polyethylene (PE-AL-PE) Composite Pressure-Pipe Systems Table 1202.4
B137.10—02 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure-Pipe Systems Table 1202.4
ANSI CSA America FC1-03 Stationary Fuel Cell Power Systems 924.1



DOL Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
Standard
reference
number
Title Referenced
in code
section number
29 CFR Part 1910.1000 (1974) Air Contaminants 502.6
29 CFR Part 1910. 1025 Toxic and Hazardous Substances 502.19



FS Federal Specifications*
General Services Administration
7th & D Streets
Specification Section, Room 6039
Washington, DC 20407
Standard
reference
number
Title Referenced
in code
section number
WW-P-325B (1976) Pipe, Bends, Traps, Caps and Plugs; Lead (for Industrial Pressure and Soil and Waste Applications Table 1202.4

*Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325.



ICC International Code Council, Inc.
500 New Jersey Ave, NW
6th Floor
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
IBC—09 International Building Code® 201.3, 202, 301.12, 301.12, 301.14, 301.15, 302.1, 302.2, 304.7, 304.10, 308.8, 308.10, 401.4, 401.6, 406.1, 502.10, 502.10.1, 504.2, 506.3.3, 506.3.10, 506.3.12.2, 506.4.1, 509.1, 510.6, 510.6.3, 510.6.2, 510.7, 511.1.5, 513.1, 513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.2.1, 513.6.2, 513.10.5, 513.12, 513.12.2, 513.20, 602.2.1.5.1, 602.2.1.5.2, 602.3, 603.1, 603.10, 604.5.4, 607.1.1, 607.3.2.1, 607.5.1, 607.5.2, 607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.5.5.1, 607.6, 607.6.2, 701.4.1, 701.4.2, 801.3, 801.16.1, 801.18.4, 902.1, 908.3, 908.4, 910.3, 925.1, 1004.6, 1105.1, 1206.4, 1402.4, 1402.4.1
IEBC—09 International Existing Building Code® 101.2
IECC—09 International Energy Conservation Code® 202, 301.2, 303.3, 312.1, 603.9, 604.1, 1204.1, 1204.2
IFC—09 International Fire Code® 201.3, 310.1, 311.1, 502.4, 502.5, 502.7.2, 502.8.1, 502.9.5, 502.9.5.2, 502.9.5.3, 502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.10, 502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.4, 511.1.1 513.12.3, 513.15, 513.16, 513.17, 513.18, 513.19, 513.20.2, 513.20.3, 606.2.1, 908.7, 1101.9, 1105.3, 1106.5, 1106.6, 1301.1, 1301.2
IFGC—09 International Fuel Gas Code® 101.2, 201.3, 301.3, 701.1, 801.1, 901.1, 906.1, 1101.5
IPC—09 International Plumbing Code® 201.3, 301.8, 512.2, 908.5, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1401.2
IRC—09 International Residential Code® 101.2



IIAR International Institute of Ammonia Refrigeration
1110 North Glebe Road
Arlington, VA 22201
Standard
reference
number
Title Referenced
in code
section number
2—99 (with Addendum A-2005) Addendum A to Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems 1101.6



MSS Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
Standard
reference
number
Title Referenced
in code
section number
SP-69—2002 Pipe Hangers and Supports—Selection and Application 305.4



NAIMA North American Insulation Manufacturers Association
44 Canal Center Plaza, Suite 310
Alexandria, VA 22314
Standard
reference
number
Title Referenced
in code
section number
AH116—02 Fibrous Glass Duct Construction Standards 603.5, 603.9



NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
Standard
reference
number
Title Referenced
in code
section number
30A—08 Code for Motor Fuel-dispensing Facilities and Repair Garages 304.6
31—06 Installation of Oil-burning Equipment 801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1
37—06 Stationary Combustion Engines and Gas Turbines 915.1, 915.2
58—08 Liquefied Petroleum Gas Code 502.9.10
69—08 Explosion Prevention Systems 510.8.3
70—08 National Electrical Code 301.7, 306.3.1, 306.4.1, 511.1.1, 513.11, 513.12.1, 602.2.1.1, 1106.3, 1106.4
72—07 National Fire Alarm Code 606.3
82—04 Incinerators and Waste and Linen Handling Systems and Equipment 601.1
91—04 Exhaust Systems for Air Conveying of Vapors, Gases, and Noncombustible Particulate Solids 502.9.5.1, 502.17
92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 513.8
211—06 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 806.1
262—07 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-handling Spaces 602.2.1.1
704—07 Identification of the Hazards of Materials for Emergency Response 502.8.4, Table 1103.1, 510.1
720—12 Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment 313.4.5.1, 313.4.5.2, 313.4.6
853—07 Installation of Stationary Fuel Power Plants 924.1
8501—97 Single Burner Boiler Operation 1004.1
8502—99 Prevention of Furnace Explosions/Implosions in Multiple Burner Boiler-furnaces 1004.1
8504—96 Atmospheric Fluidized-bed Boiler Operation 1004.1



SMACNA Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Drive
Chantilly, VA 20151-1209
Standard
reference
number
Title Referenced
in code
section number
SMACNA/ANSI—2005 HVAC Duct Construction Standards—Metal and Flexible (2005) 603.4, 603.9
SMACNA—03 Fibrous Glass Duct Construction Standards 603.5, 603.9



UL Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
Standard
reference
number
Title Referenced
in code
section number
17—94 Vent or Chimney Connector Dampers for Oil-fired Appliances—with Revisions through September 1999 803.6
58—96 Standard for Steel Underground Tanks for Flammable and Combustible Liquids 1309
80—09 Standard for Steel Tanks for Oil-burner Fuels and Other Combustible Liquids 1309
103—01 Factory-built Chimneys, Residential Type and Building Heating Appliance—with Revisions through June 2006 805.2
127—96 Factory-built Fireplaces—with Revisions through November 2006 805.3, 903.1, 903.3
142—2010 Standard for Steel Above ground Tanks for Flammable and Combustible Liquids 1309
174—04 Household Electric Storage Tank Water Heaters—with Revisions through May 2006 1002.1
181—05 Factory-made Air Ducts and Air Connectors—with Revisions through December 1998 512.2, 603.5, 603.6.1, 603.6.2, 604.13
181A—05 Closure Systems for Use with Rigid Air Ducts and Air Connectors—with Revisions through December 1998 603.9
181B—05 Closure Systems for Use with Flexible Air Ducts and Air Connectors—with Revisions through December 1998 603.9
207—01 Refrigerant-containing Components and Accessories, Nonelectrical—with Revisions through November 2004 1101.2
UL 217 Single and Multiple Station Smoke Alarms—with Revisions through May 2007 313.4.4.3
263—03 Standard for Fire Test of Building Construction and Materials 607.5.2, 607.5.5, 607.6.1
268—06 Smoke Detectors for Fire Prevention Signaling Systems—with Revisions through October 2003 313.4.5.3, 606.1
268A—98 Smoke Detectors for Duct Applications—with Revisions through April 2006 606.1
343—97 Pumps for Oil-Burning Appliances—with Revisions through May 2006 1302.7
391—2006 Solid-fuel and Combination-fuel Central and Supplementary Furnaces 918.1
412—04 Refrigeration Unit Coolers—with Revisions through February 2007 1101.2
471—06 Commercial Refrigerators and Freezers—with Revisions through March 2006 1101.2
507-99 9th Edition Standard for Electric Fans 931
508—99 Industrial Control Equipment—with Revisions through July 2005 307.2.3
536—97 Flexible Metallic Hose—with Revisions through June 2003 1302.8
555—06 Fire Dampers—with Revisions through January 2002 607.3
555C—06 Ceiling Dampers 607.3.1
555S—99 Smoke Dampers—with Revisions through July 2006 607.3.1
586—96 High-efficiency, Particulate, Air Filter Units—with Revisions through August 2004 605.2
641—95 Type L Low-temperature Venting Systems—with Revisions through August 2005 802.1
710—95 Exhaust Hoods for Commercial Cooking Equipment—with Revisions through February 2007 507.1
710B—04 Recirculating Systems 507.1
723—03 Standard for Test for Surface Burning Characteristics of Building Materials— with Revisions through May 2005 510.8, 602.2.1, 602.2.1.5, 604.3, 1204.1
726—95 Oil-fired Boiler Assemblies—with Revisions through March 2006 916.1, 1004.1
727—06 Oil-fired Central Furnaces 918.1
729—03 Oil-fired Floor Furnaces—with Revisions through January 1999 910.1
730—03 Oil-fired Wall Furnaces—with Revisions through January 1999 909.1
731—95 Oil-fired Unit Heaters—with Revisions through February 2006 920.1
732—95 Oil-fired Storage Tank Water Heaters—with Revisions through February 2005 1002.1
737—96 Fireplace Stoves—with Revisions through January 2000 905.1
762—03 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances 506.5.1
791—06 Residential Incinerators 907.1
834—04 Heating, Water Supply and Power Boilers Electric—with Revisions through March 2006 1004.1
858—05 Household Electric Ranges—with Revisions through April 2006 917.1
867—00 Electrostatic Air Cleaners—with Revisions through May 2004 605.2
875—04 Electric Dry Bath Heater—with Revisions through March 2006 914.2
896—93 Oil-burning Stoves—with Revisions through May 2004 917.1, 922.1
900—04 Air Filter Units 605.2
923—02 Microwave Cooking Appliances—with Revisions through February 2006 914.2
959—01 Medium Heat Appliance Factory-built Chimneys—with Revisions through September 2006 805.5
1240—05 Electric Commercial Clothes 913.1
1261—01 Electric Water Heaters for Pools and Tubs—with Revisions through June 2004 916.1
1453—04 Electric Booster and Commercial Storage Tank Water Heaters—with Revisions through May 2006 1002.1
1479—03 Fire Tests of Through-penetration Firestops—with Revisions through April 2007 506.3.10.2, 506.3.10.3
1482—96 Solid-fuel Type Room Heaters—with Revisions through November 2006 905.1
1777—04 Chimney Liners 801.16.1, 801.18.4
1812—05 Standard for Ducted Heat Recovery Ventilators—with Revisions through January 2006 927.1
1815—01 Standard for Nonducted Heat Recovery Ventilators—with Revisions through January 2006 927.2
1820—04 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics 602.2.1.3
1887—04 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics 602.2.1.2
1978—95 Grease Ducts 506.3.2
1995—05 Heating and Cooling Equipment 911.1, 918.1, 918.3, 1101.2
UL 2034 Standard for Safety for Single and Multiple Station Carbon Monoxide Alarms 313.3, 313.4.4.2, 313.4.4.3
2043—08 Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories Installed in Air-handling Spaces 602.2.1.4.2
UL 2075 Standard for Gas and Vapor Detectors and Sensors 313.4.5.1, 313.4.5.3
2158—97 Electric Clothes Dryers—with Revisions through May 2004 504.6.3, 913.1
2158A—2006 Outline of Investigation for Clothes Dryer Transition Duct 504.6.3
2162—01 Outline of Investigation for Commercial Wood-fired Baking Ovens—Refractory Type 917.1
2200—04 Stationery Engine Generator Assemblies 915.1
2221—01 Tests of Fire Resistive Grease Duct Enclosure Assemblies 506.3.10.3
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING