Appendix 1 Residential Requirements

AMENDMENT
This section has been amended at the state or city level.
Appendix 1.1. Energy Efficiency Certificate (Section 401.3)

TABLE 401.9
ENERGY EFFICIENCY CERTIFICATE
Builder, Permit Holder or Registered Design Professional
Print Name:

Signature:
Property Address:
Date:
Insulation Rating - List the value covering largest area to all that apply R-Value
Ceiling/roof: R-
Wall: R-
Floor: R-
Closed Crawl Space Wall: R-
Closed Crawl Space Floor: R-
Slab: R-
Basement Wall: R-
Fenestration:
U-Factor
Solar Heat Gain Coefficient (SHGC)
Building Air Leakage
□ Visually inspected according to 402.4.2.1 OR
□ Building Air Leakage Test Results
    (Sec. 402.4.2.2)
    ACH50 [Target: 5.0] or
    CFM50/SFSA [Target: 0.30]
Name of Tester/Company:

Date:                     Phone:
Ducts:
Insulation R-
Total Duct Leakage Test Result (Sect. 403.2.2)
(CFM25 Total/100SF) [Target: 6]
Name of Tester or Company:

Date:                     Phone:
Certificate to be displayed permanently


APPENDIX 1.2
INSULATION AND AIR SEALING DETAILS

APPENDIX 1.2.1

402.2.1 Ceilings with attic spaces. Exception for fully enclosed attic floor systems

SECTION VIEW OF CEILING WITH ATTIC SPACE


APPENDIX 1.2.2

402.2.9 Closed crawl space walls. Insulation illustrations

Foam or porous insulation has 3" top inspection gap and extends down 3" above top of wall footing or concrete floor



Foam or porous insulation has 3" top inspection gap and extends down 3" above interior ground surface



Foam or porous insulation has 3" top inspection gap and extends down 24" below grade



APPENDIX 1.2.3

402.2.12 Framed cavity walls. Insulation enclosure — 1. Tubs

SECTION VIEW OF BATH TUB ON EXTERIOR WALL


402.2.12 Framed cavity walls. Insulation enclosure — 2. Showers

SECTION VIEW OF SHOWER ON EXTERIOR WALL


402.2.12 Framed cavity walls. Insulation enclosure — 3. Stairs

SECTION VIEW OF INTERIOR STAIRCASE ON EXTERIOR WALL
(OPTION 1)


402.2.12 Framed cavity walls. Insulation enclosure — 3. Stairs

SECTION VIEW OF INTERIOR STAIRCASE ON EXTERIOR WALL
(OPTION 2)


402.2.12 Framed cavity wall. Insulation enclosure — 4. Direct vent gas fireplace

SECTION VIEW OF DIRECT VENT GAS FIREPLACE


402.2.12 Framed cavity walls. Insulation enclosure — 5. Walls that adjoin attic spaces

SECTION VIEW OF WALL ADJOINING ATTIC SPACE


402.2.12 Framed cavity walls. Insulation enclosure — 5. Walls that adjoin attic spaces

SECTION VIEW OF WALL ADJOINING ATTIC SPACE


402.4.1 Building thermal envelope. — 1. Block and seal floor/ceiling systems

ISOMETRIC VIEW OF DIMENSIONAL LUMBER FLOOR/CEILING SYSTEM
ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE


402.4.1 Building thermal envelope. — 1. Block and seal floor/ceiling systems

ISOMETRIC VIEW OF WOOD TRUSS FLOOR/CEILING SYSTEM
ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE


402.4.1 Building thermal envelope. — 1. Block and seal floor/ceiling systems

ISOMETRIC VIEW OF I-JOIST FLOOR/CEILING SYSTEM
ABOVE COMMON WALL BETWEEN UNCONDITIONED AND CONDITIONED SPACE


402.4.1 Building thermal envelope. — 2. Cap and seal shafts and chases



SECTION VIEWS OF DUCT PENETRATING INTO ATTIC
402.4.1 Building thermal envelope. — 3. Cap and seal soffit or dropped ceiling

SECTION VIEW OF SOFFIT OVER CABINET


402.4.1 Building thermal envelope. — 4. Seal HVAC boot penetration — floor

SECTION VIEW OF FLOOR HVAC BOOT PENETRATION


402.4.1 Building thermal envelope. — 4. Seal HVAC boot penetration — ceiling

SECTION VIEW OF CEILING HVAC BOOT PENETRATION