Chapter 1 Material and Equipment Application Procedures

Chapter 2 Boiler Inspections

Chapter 3 Vacant and Unguarded Buildings

Chapter 4 Certificates of Occupancy, Live Loads and Occupancy Loads

Chapter 5 Concrete

Chapter 6 Cranes

Chapter 8 Demolition

Chapter 9 Rigging Operations

Chapter 10 Drums for Derrick Load and Boom Hoists

Chapter 11 Elevators, Escalators, Personnel Hoists and Moving Walks

Chapter 12 Emergency Power Systems

Chapter 13 Adjudications

Chapter 14 Fees [Repealed]

Chapter 15 Fire Protection

Chapter 16 Inspection of Existing Structures During Construction Operations

Chapter 17 Testing Laboratories and Testing Services

Chapter 18 Resistance to Progressive Collapse Under Extreme Local Loads

Chapter 19 Master Plumbers and Licensed Fire Suppression Piping Contractors

Chapter 20 Piping Systems

Chapter 21 Plans

Chapter 22 Pressure Tanks

Chapter 23 Noncommercial Greenhouses

Chapter 24 Refuse Chutes and Refuse Rooms

Chapter 25 Climber and Tower Crane Riggers

Chapter 27 Signs

Chapter 28 Smoke Detecting Devices and Systems and Carbon Monoxide Detecting Devices and Systems

Chapter 29 Sprinkler Systems

Chapter 30 Storage of Certain Waste Materials

Chapter 31 Suspension, Revocation or Limitation of Registration [Repealed]

Chapter 32 Walls [Repealed]

Chapter 33 Exemptions From Civil Penalties

Chapter 34 Electrical Code Rules

Chapter 35 Electrical Inspection

Chapter 36 Electrical Contractors

Chapter 37 Reference Standards

Chapter 38 Ventilation

Chapter 39 Cooling Towers and Evaporative Condensers

Chapter 40 Installation and Maintenance of Gas-Fueled Water and Space Heaters in All Portions of Dwellings Used or Occupied for Living Purposes

Chapter 41 Venting of Gas Water Heaters and Other Gas Appliances in Multiple Dwellings

Chapter 42 Entrance Doors, Locks and Intercommunication Systems

Chapter 43 Installation of Security Items in Multiple Dwellings

Chapter 44 Exemptions From Filing Requirements [Repealed]

Chapter 45 Building Permit Application Procedures

Chapter 46 Authorized Representatives

Chapter 48 Construction Superintendents [Repealed]

Chapter 49 Outdoor Signs

Chapter 50 Distributed Energy Resource Standards

Chapter 51 Dormitories

Chapter 52 Notification to the Department of Commencement of Work Pursuant to an Earthwork Permit

Chapter 100 [Administration; Enforcement; Maintenance of Buildings; Licensing; Miscellaneous Provisions]

Chapter 300 Use and Occupancy Classification

Chapter 400 Special Detailed Requirements Based on Use and Occupancy

Chapter 900 Fire Protection Systems

Chapter 1000 Means of Egress

Chapter 1100 Accessibility

Chapter 3000 Elevators and Conveying Systems

Chapter 3300 Safeguards During Construction and Demolition

Chapter 3500 Referenced Standards

Chapter 3600 Appendices

Chapter 4000 Electrical Code

Chapter 5000 New York City Energy Conservation Code

Chapter 6000 Fuel Gas Code

Chapter 7000 Mechanical Code

Chapter 8000 New York City Plumbing Code

Chapter 9000 Zoning

Get access to the 12 NYC DOB linked resources for Title 1 ‒ Department of Buildings that we've compiled so far.
LEARN MORE
Continue without linked resources
Pursuant to Section 28-103.19 of the New York City Administrative Code, ACI 318 as added by Section BC 3502 of the New York City Building Code is hereby deleted and a new ACI 318 is added to read as follows:
Table 1
 
ACI
American Concrete Institute
38800 Country Club Drive
Farmington Hills, MI 48331

Standard
Reference
Number

Referenced in code
section number
318 – 11
Building Code Requirements for Structural Concrete
406.5.4, 721.2.4.3, 1604.3.2, Table 1613.8, Table 1704.3, 1704.3.1.3, Table 1704.4, 1704.4.1 Table 1704.32, 1805.5.7.2, 1805.9, Table 1808.2.13, 1808.9.2.1, 1808.9.3, 1808.9.3.1, 1809.6.3.2, 1809.6.3.2.2, 1810.1.2.5.1, 1810.1.2.5.2, 1810.7.4.1, 1810.8.3, 1810.8.4, 1901.2, 1901.3, 1901.4, 1902.1, 1903.1, 1903.2, 1903.3, 1903.4, 1903.5, 1903.5.1, 1903.5.2, 1903.6, 1903.7, 1904.1, 1904.2, 1904.3, 1904.4.1, 1904.5, 1905.1.1, 1905.1.4, 1905.3, 1905.4, 1905.5, 1905.6.5.5, 1905.6.6, 1905.8.3, 1905.11.3, 1906.1, 1906.2, 1906.3, 1906.4, 1907.1, 1907.2, 1907.4.1, 1907.6, 1907.7.2, 1907.7.3, 1907.7.4, 1907.7.5, 1907.7.6, 1907.8, 1907.9, 1907.10, 1907.11, 1907.12, 1907.13, 1908, 1908.1, 1908.1.1, 1908.1.2, 1908.1.3, 1908.1.4, 1908.1.5, 1908.1.6, 1908.1.7, 1908.1.8, 1908.1.9, 1908.1.11, 1908.2, 1908.2.1, 1909.1, 1909.3, 1909.4, 1909.5, 1909.6, 1912.1, 1912.1.1, 1915.2, 1915.3, 1915.4, 1915.6, 1916.2, 1916.3.1, 2108.3, 2205.3, 3305.3.2
 
§ 2. This rule takes effect on December 31, 2014. [;As amended City Record Nov. 19, 2014 § 7, see also T1 §102-01 Note 16];
Pursuant to Section 28-103.19 of the New York City Administrative Code, ANSI 10.4 as added by Section BC 3502 of the New York City Building Code is hereby deleted and a new ANSI 10.4 is added to read as follows:
Table 2
 
ANSI
American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036

Standard
Reference
Number

Referenced in code
section number
A10.4 – 07
Safety Requirements for Personnel Hoists
3010.3
 
Resources