Heads up:
There are no suggested sections in this chapter.
Heads up:
There are no amended sections in this chapter.
(a) Application.
(1) No person, firm or corporation shall spray, dip or immerse any article or thing within the City of New York with any flammable paints, varnishes, lacquers or any other flammable or combustible substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes except in conformance with these rules, and under a permit issued by the Fire Commissioner. Where the quantity of spraying, dipping or immersing materials used in a day does not exceed two quarts, except for spraying as performed under §18-01(e)(13), and the total amount of material stored does not exceed twenty gallons, these rules shall not apply.
(2) Applications. Application for the required permit to store and use the above-mentioned materials shall be made to the Fire Commissioner on forms prescribed by him and shall contain such information as he may require. When a spray, dipping, immersing, storage or mixing room is to be installed, an application shall be filed with and approved by the Borough Superintendent before a permit is issued by the Fire Commis- sioner.
(3) Restrictions. No spraying, dipping or immersing of any article or thing within the City of New York with any flammable paints, varnishes, lacquers or any other flammable substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes shall be permitted in any premises or portion thereof as follows: (i) Which is occupied as a class A or B multiple dwelling or a dwelling for one or two-families, except where a location is provided which is separated by fireproof construction from the residential occupancy and ventilated as provided in §18-01(c).
(ii) Which is occupied as a place of public assembly except trade schools where the buildings are of Class I or Class II construction and spraying, dipping or immersing are demonstrated for instruction purposes only.
(iii) Which is artificially lighted by any means other than electricity.
(iv) Which is heated by other than the use of steam or hot water circulating systems and the boiler is located outside the space where spraying, dipping or immersing is carried on.
(b) Definitions.
Cabinet booth. The term "Cabinet Booth" when used in these rules shall mean a compartment with a back, top and two sides of incombustible materials over a substantial metal frame and equipped with air exhaust facilities, located within a room or any portion of any premises where spraying with any flammable paints, varnishes, lacquers or any other flammable substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes is carried on.
Canopy booth or hood. The term "Canopy Booth or Hood" when used in these rules shall mean an installation consisting of a metal canopy or hood, without any side or end panels enclosing the object sprayed and an air exhaust system under which spraying with any flammable paints, varnishes, lacquers or any other flammable substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes is carried on.
Certificate of Fitness. The term "Certificate of Fitness" when used in these rules shall mean the written permission granted by the Fire Commissioner to an individual to supervise and to process spraying, dipping and immersing materials and equipment, in accordance with the provisions of §27-4014 of the Administrative Code and these rules.
Dipping room. The term "Dipping Room" when used in these rules shall mean a fully-enclosed ventilated room approved for such use in which any article or thing is dipped, or immersed in any flammable paints, varnishes, lacquers or any other flammable substances, mixtures, or compounds commonly used for painting, varnishing, staining or similar purposes is carried on.
Fireproof or fire-resisting partitions. The term "Fireproof or Fire-Resisting Partitions" used in these rules shall mean the standards set in the Labor Law and the rules of the Board of Standards and Appeals for factory buildings (§7-01). All openings in this type of partition shall only be equipped with self-closing fireproof assemblies.
Permit. The term "Permit" when used in these rules shall mean the written permission issued to a person, firm or corporation by the Fire Commissioner, to store and use materials covered by §§27-4011 and 27-4093 of the Administrative Code and these rules.
Spray or spraying space, dipping space or immersing space. The term "spray or spraying space" "dipping space or immersing space" when used in these rules shall mean that portion of the premises used for the actual work of spraying, dipping or immersing any article or thing with any flammable paints, varnishes, lacquers or any other flammable substances, mixtures or compounds, commonly used for painting, varnishing, staining or similar purposes in any booth or room.
Spray room. The term "spray room" when used in these rules shall mean a fully enclosed ventilated room approved for such use in which any article or thing is sprayed by any flammable paints, varnishes, lacquers or any other flammable substance, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes is carried on.
Storage room. The term "storage room" when used in these rules shall mean a fully-enclosed ventilated room used for the storage and mixing of any flammable paints, varnishes, lacquers or any flammable substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes.
Tunnel booth. The term "tunnel booth" when used in these rules shall mean a compartment consisting of two sides and top, equipped with an air exhaust system in which spraying with any flammable paints, varnishes, lacquers or any other flammable substances, mixtures or compounds commonly used for painting, varnishing, staining or similar purposes is carried on.
(c) Ventilation.
(1) Spraying or dipping spaces shall be ventilated when in operation so that the movement of air shall be at least one hundred (100') linear feet per minute in the breathing zone of the operator and be of sufficient capacity to prevent the accumulation of mist or vapors. For requirements of ventilation of storage rooms see §18-0l(d)(4)(i).
(2) Air shall be admitted to the spraying, dipping or immersing spaces in an amount equal to the capacity of the fan or fans and in such a manner as to avoid short-circuiting the path of air in the working zone of such spaces. Exhaust fans shall be kept running constantly while spraying, mixing or dipping. Exhaust fan control shall be interconnected with spray gun so as to operate simultaneously. Exhaust fans shall, in addition, be arranged to operate independently of spray gun. Ventilation Equipment shall be kept in operation for a sufficient length of time thereafter to exhaust all vapors, fumes or residues of spraying materials from the spray booth, dip space or drying room. Air admitted to the spraying, dipping, immersing, drying spaces or storage rooms shall be fresh air taken from the outside of the building.
(3) Equipment. Motors shall be located outside of spraying, dipping or immersing spaces except as provided in §18-01(d).
(d) Specification for spray booths, spray rooms, dip and immersing rooms, drying equipment and material storage rooms.
(1) Spray booths shall be constructed of metal or incombustible materials satisfactory to the administrative official having jurisdiction. Ventilation and lighting for spray booths, spray rooms, dipping rooms, drying rooms and storage rooms shall comply with requirements of these rules.
(i) Spray, dip and immersing rooms shall be enclosed on all sides with partitions constructed of incombustible materials with floors in such rooms of concrete. Where such rooms are located over wooden floors, such wooden floors shall be surfaced with 1" of grout adequately reinforced or a mixture of Portland cement and sand similarly reinforced. Ceilings over such rooms shall be protected by 5/8" unsanded gypsum plaster or 7/8" of cement or sanded gypsum plaster on approved 3.0 lb metal lath or other equivalent fire resisting ceiling protection. Ventilation, lighting and heating for these rooms shall comply with the requirements of these rules. Where additional fire fighting equipment is necessary such equipment shall be furnished in accordance with the direction of the Fire Commissioner. Floor drains leading to the house draining system or the public sewer shall not be permitted. Dip tanks shall be provided with hinged metal covers held open by a fusible link, such covers to be equipped with an opening to permit automatic flooding of the tank with fire extinguishing media of a type and so located as the Fire Commissioner shall direct. Where the work process, such as conveyorized operation, makes the use of a cover impractical, the dip tank and drain boards shall be protected by an adequate extinguishing system designed for manual and automatic operation satisfactory to the Fire Commissioner and such conveyor shall be interlocked with the extinguishing system so that in the event the extinguishing system is activated, the conveyor action shall be stopped.
(ii) Panels of polished wired glass or plate-glass at least one-quarter (1/4) of an inch thick, not exceeding seven hundred and twenty (720) square inches in area and not more than forty-eight (48") inches in any linear dimension may be used in the sides of a spray booth or room.
(iii) The inner sides of walls, ceilings and the floors of all spraying or dipping spaces shall have a smooth surface.
(iv) All openings in spray, dip or immersing rooms shall be protected by fireproof opening protective assemblies. Windows opening on a street may be used to provide ventilation but no window on a lot line or less than 20 ft. from any opening in a wall of an adjacent building shall be permitted except when the subject room is more than 20 ft., in the horizontal plane, above an adjoining building.
(v) Ferrous metals used in the construction of spraying, dipping or immersing spaces shall be thoroughly painted on the inside or be galvanized.
(vi) All spraying, dipping or immersing spaces shall be so constructed that at least three (3) feet of clear working space shall always be maintained for each operator spraying, dipping or immersing the material being processed.
(2) Storage rooms. Storage rooms shall be constructed of fireproof or fire resisting material and shall have a window opening to the outer air but such window shall not be on a lot line, enclosed court, nor opposite within twenty feet of windows of adjacent buildings nor part of the same premises, such window openings to be fireproofed and lower half provided with open louvers or ventilated by metal duct or fan at least 8 inches in diameter. The floors of all storage rooms shall be of incombustible non-ferrous materials. The sill of the door shall be at least 6 inches above the finished floor. All doors to be tin-clad, approved, fireproof and self-closing. The lighting equipment shall comply with §18-01(d)(5)(ii)(B) and shall have an electric switch located outside the room. Immediately adjacent to such room shall be provided such portable fire extinguishing equipment for use within the storage room as the Fire Commissioner shall direct.
(3) Drying equipment.
(i) Gas fired drying ovens. Gas fired drying ovens shall be of a type as approved by the Board. Such ovens shall be constructed of metal and incombustible materials so designed as to preclude the direct application of flame to the materials in process. Ventilation shall be provided for each oven of sufficient capacity to maintain an oven vapor concentration at all times during the drying process of less than 1/4 the low explosive limit of the solvent used. All oven openings shall be maintained at a negative pressure relative to room pressure for inward flow. The controls for the safety exhaust and recirculating fans shall be properly interlocked with the gas supply line so that when the gas is flowing the fans are in operation. A time delay relay shall be installed to provide a minimum of four oven volume changes with fresh air and in the case of an indirect fired type of oven simultaneous purging of the combustion chamber before the ignition system can be energized and gas flow started. Each oven shall be equipped with gas burning equipment approved for such use and with electrical controls so arranged as to shut off the gas valve when ignition fails or the gas supply pressure drops to 2 inches of water. The use of a continuous gas pilot light is prohibited unless an automatic gas shut off valve is provided which will shut the gas off at the pilot light when the flame is extinguished or the supply of gas cut off. Electrical pilot ignition shall be of the continuous type or equal in performance, designed for use in high temperatures, with controls so inter-locked as to shut off the gas supply when current is interrupted. An auxiliary manually operated gas shut off valve shall be located not nearer than 25 feet from the oven so as to control the gas supply in the event of an emergency. Such ovens shall be adequately insulated on all sides and top to limit the maximum surface temperature to 140°F and to 160°F on the base, unless the floor is protected by a 3 inch mat of reinforced concrete placed over and bonded into the existing concrete floor and projecting not less than 6 inches outside the projected area of the equipment or unless an unenclosed clear air space not less than 4 inches above the concrete floor is maintained between the floor and the underside of the oven. The burner section of gas fired drying ovens shall not be located nearer than 25 feet from spraying or dipping spaces except when separated by fire proof construction, in which case the distance between burner section and spray or dip space shall be not less than 25 feet measured in the shortest line of travel.
(ii) Electric infra-red ray drying ovens. Electric Infra- Red Ray Drying Ovens shall be of a type as approved by the Board. Such ovens shall be constructed of electric equipment installed in accordance with the National Electric Code and the requirements of the Bureau of Electrical Control. Ovens when erected shall be placed on concrete floors without any additional protection, provided that at least 12 inches of clear space above the floor is provided to permit adequate ventilation.
(A) In drying processed material involving the evaporation of considerable amounts of flammable solvents by infra-red lamps, such installations shall not be confined in small rooms unless such rooms are thoroughly ventilated by a power driven ventilation system of sufficient capacity to maintain a vapor concentration at all times during the drying process of less than 1/4 the low explosive limit of the solvent used; the controls of the ventilation system to be so inter-locked with the Infra-Red Ray System that the latter cannot function unless the ventilating system is in operation. When equipped with duct ventilating system, the Infra-Red Ray Oven shall be adequately secured so as to prevent moving.
(B) Where the evaporation of a considerable amount of flammable vapors are involved, ventilated hoods located as near to the floor as practicable or enclosures shall be provided at the initial stage of the process with adequate exhaust system to discharge the primary evaporation from the solvents to the outer air, so that when the processed material progresses through the lamp drying tunnels only a comparatively small amount of solvent is left for evaporation. A space between such ventilating section and the drying section shall be maintained.
(C) Lamps and other electrical equipment shall be kept free from flammable deposits and adequate cleaning shall be maintained.
(D) Lamp and resistance heater type drying units shall be separated from spraying and dipping processes complying with these rules by a distance of at least 15 feet or shall be installed in a separate fireproof room.
(E) Controls shall be arranged so that the lamps in the tunnels will be shut off automatically if and when the conveyor stops.
(F) Where there are no conveyors and the material being processed is left stationary in the dryer there shall be an excessive temperature switch to shut off the lamps or resistance heaters to avoid overheating the material being processed if it is not removed from the dryer in time.
(G) Material to be processed on the conveyors shall be rigidly supported so as not to be liable to displacement and cause lamp breakage and short circuits. Where there are no conveyors, materials should be fixed on dollies running on tracks or other equivalent method to accomplish the same result.
(iii) The temperature of the air contacting the processed material or of the material itself shall not be higher than that to which such material can be safely subjected.
(iv) Such fire fighting equipment suitable for electrical and solvent vapor fires shall be provided as the Fire Commissioner may direct.
(4) Specifications for ducts, pipes and fans.
(i) All ducts used for ventilating spray, dip or immersing spaces shall be constructed of approved incombustible materials or metal of not less than the following gauges of metal: Ducts twenty-four (24") inches or less in diameter No. 22 gauge. Ducts over twenty-four (24") inches and not over thirty-six (36") inches in diameter No. 20 gauge. Ducts exceeding thirty-six (36") inches in diameter No. 18 gauge.
(ii) Ducts shall be strongly constructed and be installed in a workmanlike manner. They shall be rigidly supported.
(iii) Ventilating ducts shall run as directly as practicable to the outer air and be protected with a hood against the weather. The exhaust terminal or hood shall also be protected with a screen of copper or bronze with a mesh not larger than one-quarter (1/4") inch.
(iv) Where a duct passes through a non-fireproof floor or roof, the duct shall be protected at such point by an outer pipe or sleeve with an air space of at least one (1") inch between the sleeve and pipe protected from the woodwork by at least a 1" blanket of asbestos, compressed rockwood or glasswool, or equivalent fire-resistive material extending through the entire depth of the ceiling construction and adequately secured to the outer pipe. The outer pipe shall be not less than two (2") inches from any woodwork and such woodwork shall be covered with at least 26 gauge metal or other incombustible material.
(v) Ventilating ducts shall not terminate within ten (10) feet measured horizontally of any chimney outlet, unprotected air intakes or within twenty (20) feet of any exit or any opening in an adjoining building.
(vi) If induced draft is used to create an air movement, the air shall be supplied from a point outside the spray or dip or immersing space. Fans and motor must be located outside the spray, or dip space, except approved explosion-proof motor and non-ferrous blade fans which, however, are not to be located where residues of spraying material may collect on such equipment.
(vii) The exhaust system from any spray, dip or immersing space shall not be connected to any other ventilating system or be discharged into a chimney or flue used for the purpose of conveying gases of combustion.
(viii) Exhaust fan blades shall be constructed of non-ferrous metal. All exhaust and ventilating fans to be permanently connected to their source of power, using metallic conduit. Rheostats in fan bases not permitted. Fan blades not coming in direct contact with spraying fumes need not comply with this requirement.
(ix) Adequate access doors or panels have tight fitting by means of screw bolts, clamps or springs shall be provided, to permit inspection and cleaning.
(5) Electrical equipment and lighting fixtures.
(i) No motors, switches, rheostats, lamps, fluorescent light or other electrical equipment shall be located in spray, dipping or immersing rooms or within ten (10') feet of the open end of any spray compartment, spray booth, immersing or dipping space unless such electrical equipment be of a type approved for use in explosive atmosphere and where a conduit leads from a hazardous location to a non-hazardous location, the conduit shall be sealed off by an approved sealing compound. Except that alternating current induction motors of the totally enclosed type, having no brushes make and break contacts, collectors or other arcing or sparking parts may be located within ten (10') feet of a spray booth, spray compartment or dipping space when approved by the administrative official having jurisdiction. No open flame shall be used within 25 ft. of spray, dip or coating space or paint storage room or cabinet except when separated by fireproof construction, except as provided in §18-01(d)(3)(i) "gas fired drying ovens" and §18-01(d)(3)(ii)(D) electric infra- red dry ovens. Nothing herein contained, nor in §18-01(g)(5) shall prohibit the use of electrostatic paint spraying equipment of a type approved by the Board under such conditions as the Board shall prescribe in its approval.
(ii) Lighting fixtures.
(A) Artificial lighting shall be only by means of electricity.
(B) When lighting fixtures are located within 10' of a spray booth, spraying space, dipping space or within a storage room they shall be of the rigid stem type, enclosing all wiring and be equipped with keyless sockets having vapor proof globes. Where exposed to breakage, globes shall be adequately protected by substantial metal guards or equivalent means. Fluorescent tube type lighting fixtures when used in spray booths or in spray and dip spaces or in storage rooms or rooms containing inflammable vapors, shall be of a type approved for use in explosive atmospheres. The auxiliaries of mercury vapor lamps shall be offset at least ten (10') feet from spray booth, spray or dip spaces unless enclosed in explosion-proof protection.
(C) All electrical equipment shall be installed and grounded as provided by the Administrative Code covering electrical equipment and permanently connected to their source of current supply, using metallic conduit.
(D) No pin plug receptacles shall be used except when the use of receptacles and attachment plugs become necessary they shall be so connected to form a part of a unit device with explosion-proof interlocking switch precluding the removal of the plug when the switch is in the "on" position or by an approved explosion-proof enclosure which can seal the arc when the current is interrupted. Such receptacles and plugs shall be of the polarized type providing a connection for the grounding wire of the portable cords.
(E) All electric wiring shall be enclosed in rigid standard weight metallic conduits with explosion proof joints and fittings. Joints in metallic conduit having threaded couplings shall not have less than five (5) fully engaged threads. Where flexible connections are required a flexible fitting approved for explosive atmospheres shall be used.
(F) The use of portable cords or trailer lights are prohibited, except when flexible cord approved for hard usage containing one (1) extra insulated conductor properly connected to form a grounding connection for metal lamp guards, motor frames and all other exposed metal portions of such portable lamps and devices may be used. When portable lamps are used they shall be enclosed in a manner approved for explosive atmospheres and with substantial guards of metal to prevent breakage. Sockets shall be of the keyless moulded composition type with no exposed metal parts.
(e) Maintenance and operation.
(1) Every premises wherein a spraying, dipping, or immersing space is maintained and operated shall be continuously under the charge and supervision of one or more persons holding a certificate of fitness, whose duty shall be to see that the spray, dipping and immersing space comply with the rules and the terms of the permit are not violated. No other duties shall interfere with the enforcement of these rules while the work is in process. A copy of these rules shall be available near the space where these rules apply.
(2) Smoking or the carrying of lighted cigars, cigarettes, matches, or pipes in spray, dipping or immersing space is prohibited.
(3) No person shall be permitted within a spray space between the spray gun and the exhaust outlet while the spray gun is in use.
(4) Spraying, dip or immersing spaces, and its surroundings shall be kept clean at all times and shall be kept clear of all materials, equipment and utensils not required in the operation of the spray. Side walls, ceilings, baffle plates, etc., shall be sprayed with soap and water solution, before cleaning, or cardboard or masking paper may be fastened before any operation and after said operation all waste material shall immediately be removed from the premises.
(5) Floors within and surrounding spray, dip, or immersing spaces shall be kept clean and free from waste material at all times.
(6) Spray rooms, booths, fans, ducts, and other equipment shall be cleaned frequently and maintained in clean and efficient working condition; lacquer spraying booths shall be wet down before cleaning.
(7) Implements used for cleaning shall be made of non-ferrous material to avoid sparks.
(8) Metal waste cans with self-closing covers shall be provided for all spraying, dipping or immersing spaces and storage rooms. The number to be installed shall be determined by the administrative official having jurisdiction.
(9) Approved fire appliances shall be installed in all spraying, dipping or immersing spaces and in storage rooms as may be determined by the administrative official having jurisdiction.
(10) Accumulation of flammable waste, sweepings or deposits from spray, dip or immersing space is prohibited. All such waste shall be placed in approved waste cans and be removed from the premises at the close of work each day.
(11) All sandpapering of lead painted surfaces shall be done with wet sandpaper.
(12) When a motor vehicle is taken into a spray space, the batteries shall be disconnected before the process of spraying is begun.
(13) Before spraying is performed on elevator cars all electric power operating all elevators enclosed in a common shaft, shall be turned off. While such work is in progress portable fire extinguishers shall be provided and maintained adjacent to the work as the Fire Commissioner shall direct. Such shafts shall be well ventilated of fumes before starting elevators.
(14) Flammable solvents used for cleaning equipment or for any other purpose shall not be discharged into the house drain.
(f) Material storage and mixing.
(1) Main supplies of spray coating and dipping materials and thinners shall be kept in an outside storage building, storage rooms or in vented metal cabinets in accordance with the following amounts:
(i) Spraying materials not in excess of 100 gallons may be stored in single walled metal cabinets ventilated to the outer air. Such cabinet to be metal covered on all sides, including the doors and arranged for ventilation at top and bottom.
(ii) Spraying materials not in excess of 200 gallons may be stored in double-walled metal cabinets ventilated to the outer air or wood cabinets metal covered on all sides, including the door, and arranged for ventilation at top and bottom, to the outer air.
(iii) Spraying materials in excess of 200 gallons shall be stored in a separate exterior storage building of fire-proof or fire-resisting material with ventilated plain glass skylight or in a storage room constructed fire-proof in a fireproof building or fire-resisting in a non-fireproof building. The maximum amount of spraying materials to be stored in a storage room of a non-fireproof building shall be determined by the administrative official having jurisdiction.
(iv) Mixing or thinning of coating materials shall be conducted in a storage building or storage room, except that containers of total capacity not exceeding ten gallons may be opened and their contents mixed in the spray room or room in which booths are located while the air exhaust system is operating.
(v) Working supplies sufficient for not more than one day's use but not exceeding twenty gallons to each booth, nor a total of hundred gallons, may be kept in the spray room or room in which spray booths are located; covers of containers must be kept thereon when such containers are not actually in use. This amount is in addition to the amount allowed in §18-01(f)(1)(vii).
(vi) Gravity feed material containers for supplying spray guns shall not exceed ten gallons in capacity and shall be supported by wire cables or metal brackets having a factor of safety of four when filled with the heaviest spraying materials used.
(vii) Pressure feed tanks and other equipment for use in connection with direct spraying under air pressure shall be restricted to tanks of not more than sixty gallons, individual capacity, designed, constructed and approved for this specific purpose by the Board of Standards and Appeals. Each tank shall be provided with a safety valve set at a pressure not exceeding eighty pounds. All gravity feed containers and other spraying equipment shall be approved as above.
(viii) The installation of all electrical wiring, switches, lighting and all other electrical equipment, and the provisions of these rules against carrying matches or smoking and prohibiting flame or spark-producing devices, shall also apply to storage or mixing rooms.
(2) Storage of materials where nitro cellulose products are manufactured. Storage of spraying, dipping and immersing materials shall be as provided in §18-01(f)(1)(i) through (iii), but in a building in which nitro cellulose products are manufactured, stored or kept the amount shall be not over twenty-five (25) gallons as per §27-4200, subdivision (h) of the Administrative Code.
(3) Sprinklers. Sprinkler heads shall be provided in all spray, dip or immersing spaces and storage rooms and shall be installed in accordance with the Sprinkler rules of the Board of Standards and Appeals §10-02, except in non-sprinklered buildings where sprinkler connection may be made to the house water supply, provided the size of the house water supply line is adequate for the number of sprinkler heads.
(4) Maintenance of sprinkler heads. Sprinkler heads in spraying, dipping and immersing spaces shall be cleaned at least once a week under the supervision of the person holding the certificate of fitness and a coating of light grease or vaseline shall be applied after each cleaning to prevent the formation of a hard deposit and render the sprinkler useless in case of fire. The use of paper bags or other materials about sprinkler heads is prohibited.
(g) General requirements. Notice — Attention is called to the provisions of the Administrative Code as to violations reading as follows: Section 27-4254 of the Administrative Code, "Any person who shall willfully violate or neglect or refuse to comply with any of the provisions of this chapter in addition to any other penalties prescribed by law or ordinance shall, upon conviction, be punished by a fine of not more than $500 or by imprisonment not exceeding 6 months, or by both such fine and imprisonment." Note: The principal cause of fires in spray-booth installations are: broken electric lamps and other electrical defects; cleaning the interior booths, fans and motors with highly flammable solvents; accumulation of deposits in the tubes and vent pipes from neglect in cleaning them frequently; unnecessary accumulation of waste and refuse, smoking and a general lack of cleanliness.
(1) "No Smoking" signs, — with letters at least 2 inches in height, shall be posted at entrances to and in all spray rooms and paint storage rooms or building.
(2) No combustible materials shall be stored or maintained within 15 feet of any spray booth.
(3) All stocks shall be arranged so as not to interfere with the operation of automatic sprinkler heads.
(4) Adequate mechanical or natural ventilation shall be provided.
(5) No open flames or devices creating open flames or arcs shall be maintained within 25 feet of the spray or dipping process.
(6) The premises where painting, dipping or immersing is performed shall be kept clear of empty paint cans, rubbish, paint accumulations and other combustible material.
(h) Existing spray booths and installations. These sections shall be retroactive in the following respects;
§18-01(a)(3)(iv) | Heating of Rooms. |
§18-01(c)(1) | Air Exhaust System. |
§18-01(c)(2) | Air Supply and Mixing. |
§18-01(d) | Specifications for Spray Booths, Spray Rooms,Dip and Immersing Rooms, New Drying Equipment, and Material Storage Rooms. |
§18-01(d)(1)(iii) | Surfacing of Booths. |
§18-01(d)(1)(v) | Surfacing of Metal in Booths. |
§18-01(d)(3)(ii) | Maintenance of Ducts. |
§18-01(d)(4)(vi) | Method of Induced Draft. |
§18-01(d)(5)(i) | Electrical Equipment. |
§18-01(d)(5)(ii) | Electrical Lighting. |
§18-01(e)(1) | Certificate of Fitness. |
§18-01(e)(2) | Smoking, Matches, etc. |
§18-01(e)(6) | Maintenance of Equipment. |
§18-01(e)(7) | Cleaning Implements. |
§18-01(e)(9) | Fire Appliances. |
§18-01(e)(10) | Accumulation and disposal of waste materials. |
§18-01(e)(12) | Motor vehicles in booths or rooms. |
§18-01(e)(13) | Spraying Elevator Cabs. |
§18-01(f) | Material, Storage and Mixing. |
§18-01(g) | General Requirements. |
§18-01(h) | Section 18-01(f)(1), (2), (3) and (4) may not be applied in fireproof buildings equipped with an approved existing automatic sprinkler system where the general conditions of cleanliness are properly maintained at all times. |
(i) Permits and plans. Before a permit is issued by the Fire Commissioner, plans shall be filed with the Borough Superintendent, stating name, address, floor and space where the painting, dipping or spraying processes or storage room are to be installed. Such plan shall include a complete layout of the proposed installation and shall clearly indicate the location of all exterior wall openings, in premises and adjacent buildings, exits, chimneys, vent openings and proposed processes. Plans shall be filed with the Borough Superintendent for storage and mixing rooms. Such plans shall show the complete floor plan of the proposed equipment and the location of the proposed equipment with respect to the storage and mixing rooms, exterior wall openings, in premises and adjacent buildings, exits and all chimneys within 20 feet of storage rooms and vent openings.