Heads up:
There are no amended sections in this chapter.
The "Special Lower Manhattan District" established in this Resolution is designed to promote and protect public health, safety, general welfare and amenity. These general goals include, among others, the following specific purposes:
- encourage development of a 24-hour community through the conversion of older commercial buildings to residential use;
- facilitate maximum design flexibility of buildings and enhance the distinctive skyline and streetscape of Lower Manhattan;
- improve public use and enjoyment of the East River waterfront by creating a better physical and visual relationship between development along the East River and the waterfront area, public access areas and the adjoining upland community;
- enhance the pedestrian environment by relieving sidewalk congestion and providing pedestrian amenities;
- restore, preserve and assure the use of the South Street Seaport Subdistrict as an area of small historic and restored buildings, open to the waterfront and having a high proportion of public spaces and amenities, including a South Street Seaport Environmental Museum, with associated cultural, recreational and retail activities;
- establish the Historic and Commercial Core to protect the existing character of this landmarked area by promoting development that is harmonious with the existing scale and street configuration;
- establish the Water Street Subdistrict to improve the urban design relationship between existing buildings and open areas by promoting retail activities and the enhancement of existing public spaces with new amenities in this area; and
- promote the most desirable use of land and thus conserve and enhance the value of land and buildings, and thereby protect the City's tax revenues.
Except as modified by the express provisions of the Special Lower Manhattan District, the regulations of the underlying zoning districts shall remain in effect.
Requirements that apply generally throughout the District are set forth in the provisions for this Chapter. The provisions of Section 91-40 (MANDATORY DISTRICT PLAN ELEMENTS) specify planning and urban design features that are primarily oriented toward the accommodation and well-being of pedestrians.
For requirements that are not generally applicable but are tied to specific locations within the Special District, the locations where these requirements apply are shown on District Map 2 (Street Wall Continuity Types 1, 2A, 2B & 3), Map 3 (Street Wall Continuity Types 4 & 5), Map 4 (Designated Retail Streets) and Map 5 (Curb Cut Prohibitions) in Appendix A. Certain sign regulations that apply to landmark buildings with street walls fronting Broadway are set forth in Section 91134.
The provisions of Article VI, Chapter 2 (Special Regulations in the Waterfront Area), shall apply to all areas of the waterfront area within the Special Lower Manhattan District, except as otherwise provided in Section 91-60 (REGULATIONS FOR THE SOUTH STREET SEAPORT SUBDISTRICT) for Piers 9, 11, 13 and 14. Piers 9, 11, 13 and 14 are shown on Maps 1 and 6 in Appendix A.
In flood zones, or for transit-adjacent sites or qualifying transit improvement sites, as defined in Section 66-11 (Definitions), in the event of a conflict between the provisions of this Chapter and the provisions of Article VI, Chapter 4 (Special Regulations Applying in Flood Hazard Areas), or Article VI, Chapter 6 (Special Regulations Applying Around Mass Transit Stations), the provisions of Article VI shall control.
An existing public amenity, open or enclosed, that was a mandatory requirement or received a floor area bonus pursuant to the provisions of the former Special Greenwich Street Development District, eliminated on August 27, 1998, shall not be removed, reduced in size or in any way altered, other than pursuant to the provisions of Section 91-71 (Authorization for the Modification of Required Public Amenities).
Special regulations governing the development of three specific sites in the Special Lower Manhattan District are set forth in the following Sections:
Section 91-72 (Special Permit for Development Over or Adjacent to the Approaches to the Brooklyn Battery Tunnel)
Section 91-73 (Special Provisions for Battery Park Underpass/South Street).
District maps are located in Appendix A of this Chapter and are hereby incorporated and made an integral part of this Resolution. They are incorporated for the purpose of specifying locations where special regulations and requirements, as set forth in the text of this Chapter, apply.
Map 1 Special Lower Manhattan District
Map 2 Street Wall Continuity Types 1, 2A, 2B & 3
Map 3 Street Wall Continuity Types 4 & 5
Map 4 Designated Retail Streets
Map 5 Curb Cut Prohibitions
Map 6 South Street Seaport Subdistrict (Section 91-63)
Map 7 Subway Station Improvement Areas
Map 8 Water Street Subdistrict
Map 9 Water Street Subdistrict Arcades
In order to carry out the purposes and provisions of this Chapter, the South Street Seaport Subdistrict, the Historic and Commercial Core and the Water Street Subdistrict are established within the Special Lower Manhattan District and include specific regulations designed to advance the purpose of these areas:
- South Street Seaport Subdistrict
The South Street Seaport Subdistrict contains certain provisions that do not apply to other areas of the Special District. Except as otherwise provided in the Subdistrict regulations, the Subdistrict is subject to all other regulations of the Special Lower Manhattan District and the underlying districts. The requirements for the South Street Seaport Subdistrict are set forth in Section 91-60 (SPECIAL REGULATIONS FOR THE SOUTH STREET SEAPORT SUBDISTRICT).
The Subdistrict is shown on Map 1 (Special Lower Manhattan District) and Map 6 (South Street Seaport Subdistrict) in Appendix A of this Chapter. - The Historic and Commercial Core
The Historic and Commercial Core has been established to promote development compatible with existing buildings that border the area whose street plan has been accorded landmark status by the New York City Landmarks Commission as the Streetplan of New Amsterdam and Colonial New York. Height and setback provisions for the Historic and Commercial Core are set forth in Sections 91-31 through 91-33.
The Core is bounded by Broadway and Wall, Whitehall and Water Streets, as shown on Map 1 (Special Lower Manhattan District) in Appendix A of this Chapter. - Water Street Subdistrict
The Water Street Subdistrict has been established to improve the urban design relationship between existing buildings and open areas by promoting retail activities and the enhancement of existing public spaces with new amenities in this area.
The Subdistrict is shown on Map 8 (Water Street Subdistrict) and Map 9 (Water Street Subdistrict Arcades) in Appendix A of this Chapter.
Within the Special Lower Manhattan District, buildings containing residences may be developed or enlarged in accordance with the provisions of Article II, Chapter 8 (The Quality Housing Program), except that the bulk regulations for Quality Housing buildings set forth in Article II, Chapter 3 (Residential Bulk Regulations in Residence Districts) and modified by Article III, Chapter 5 (Bulk Regulations for Mixed Buildings in Commercial Districts), shall be superseded by the bulk regulations of this Chapter. Recreation space required pursuant to Section 28-20 (RECREATION SPACE AND PLANTING AREAS) shall be in addition to any recreation space required pursuant to this Chapter.
Within the Special Lower Manhattan District, the following Board of Standards and Appeals special permits shall not be applicable or shall be applicable only as modified.
The following special permit by the Board of Standards and Appeals shall not be applicable:
Section 73-68 (Modifications of Height, Setback and Rear Yard Regulations)
The following special permits by the Board of Standards and Appeals shall be applicable as modified:
Section 73-21 (Automotive Service Stations) shall not apply on zoning lots with frontage on any street listed on Map 2 or Map 4 in Appendix A
Section 73-244 (In C2, C3, C4*, C6-4**,M1-5B, M1-5M and M1-6M Districts, the Special Hudson Square District and the Special Tribeca Mixed Use District) shall also apply in C5 Districts to eating or drinking establishments with entertainment, including musical entertainment or dancing, and a capacity of more than 200 persons.
Within the Special Lower Manhattan District, the following special permits by the City Planning Commission shall not be applicable or shall be applicable within C5 Districts.
The following special permits by the City Planning Commission shall not be applicable:
Section 74-721 (Modification of Height, Setback and Yard Regulations)
Section 74-82 (Through Block Arcades)
The following special permits by the City Planning Commission shall be applicable also within C5 Districts:
Section 74-41 (Arenas, Auditoriums, Stadiums or Trade Expositions)
Section 74-46 (Indoor Interactive Entertainment Facilities).
Where the lot line of a zoning lot coincides with, or is within 20 feet of, the boundary of DeLury Square Park, such lot line shall be considered to be a street line for the purposes of applying all use and bulk regulations of this Resolution.
In addition to the special permit uses cited in Section 91-06, the use regulations for C5 Districts within the Special Lower Manhattan District are modified to permit the following uses:
From Use Group 7:
Use Groups 7B and 7E
From Use Group 8:
Use Groups 8A*, 8B and 8E
From Use Group 12:
Use Groups 12A**, 12B, 12C and 12E
___________
* inclusive of the waiting area requirements for theaters as listed in Use Group 8A
** except for eating or drinking establishments as listed in Use Group 12A
In all C5 Districts within the Special Lower Manhattan District, in addition to eating and drinking establishments permitted pursuant to Section 32-15 (Use Group 6), the following types of eating and drinking establishments shall be permitted:
eating or drinking establishments with entertainment, including musical entertainment or dancing, with a total capacity of 200 persons or fewer, provided that the dance floor or area, if any, does not exceed 400 square feet. The locational and waiting area requirements for eating or drinking establishments of Section 73-244 (In C2, C3, C4*, C6-4**, M1-5B, M1-5M and M1-6M Districts, the Special Hudson Square District and the Special Tribeca Mixed Use District) shall apply;
eating or drinking establishments with entertainment, including musical entertainment or dancing, with a capacity of more than 200 persons, pursuant to the provisions of Section 73-244, as modified in Section 91-061 (Applicability of special permits by the Board of Standards and Appeals).
In C5 Districts within the Special Lower Manhattan District, the provisions of Section 32-423 (Limitation on ground floor location) shall not apply.
On designated retail streets, as shown on Map 4 in Appendix A, for buildings developed or enlarged after August 27, 1998, where the ground floor level of such development or enlarged portion of the building fronts upon such streets, uses within stories on the ground floor or with a floor level within five feet of curb level, shall be limited to only those uses permitted by the underlying regulations and Section 91-111 (Additional uses in C5 Districts), other than automobile showrooms or plumbing, heating or ventilating equipment showrooms, or any of the uses listed in Use Groups 6B, 6E, 7C, 7D, 8C, 8D, 9B, 10B, 11 or 12D.
In the Special Lower Manhattan District, except as modified by the provisions of this Section, inclusive, the regulations of Section 32-60, et seq., pertaining to signs, shall apply.
In all C5 Districts within the Special Lower Manhattan District, not more than one illuminated, non-flashing sign, other than an advertising sign, with a total surface area not exceeding eight square feet shall be permitted for each street frontage of the zoning lot. Such sign may be located only within a window of a building.
In all C5 and C6 Districts within the Special Lower Manhattan District, in lieu of the provisions of Section 32-652 (Permitted projection in all other Commercial Districts), banners may project across a street line for a maximum distance of eight feet.
In C5-3 or C5-5 Districts within the Special District, in lieu of the provisions of Section 32-655 (Height of signs in all other Commercial Districts), banners may extend above curb level to a maximum height of 40 feet.
In C6-9 Districts within the Special Lower Manhattan District, the regulations of Section 32-655 (Height of signs in all other Commercial Districts) may be modified to allow a maximum height of 50 feet above curb level, provided the City Planning Commission certifies that the design features of the existing building, as they appear on May 9, 2001, would unduly obstruct the visibility of the sign without such modification. An application for such certification shall be filed with detailed plans showing compliance with this Section.
In addition to signs and banners otherwise permitted pursuant to Section 91-13, et seq., within 100 feet of Broadway in C5-5 Districts, on any building with a street wall fronting Broadway that is a landmark designated by the Landmarks Preservation Commission, the applicable sign regulations of Section 32-60 shall be modified according to the following provisions, provided such signs and any alterations to the building connected with such signs have received a certificate of appropriateness or other permit from the Landmarks Preservation Commission.
- Illuminated non-flashing signs other than advertising signs are permitted with a total surface area (in square feet) not to exceed 50 square feet along any street frontage.
- No permitted sign shall extend above curb level at a height greater than 30 feet.
- No permitted sign shall project across a street line more than 60 inches.
- Permitted signs displayed on awnings may also include commercial copy related to the type of business, profession, commodity, service or entertainment conducted, sold or offered within such building.
The basic maximum floor area ratio on a zoning lot is specified in the table in Section 91-22 (Floor Area Increase Regulations) and may be increased only pursuant to the floor area increase and bonus provisions of this Chapter.
Notwithstanding the floor area increase and bonus provisions of this Chapter, the maximum permitted floor area ratio on a zoning lot for residential use shall be 12.0.
The basic maximum floor area ratio (FAR) of the underlying district may be increased by the inclusion of specific additional bonus floor area for a maximum floor area ratio as specified in the table in this Section.
The provisions of paragraph (c) of Section 74-792 (Conditions and limitations), pertaining to the transfer of development rights from landmark sites, shall be subject to the restrictions on the transfer of development rights (FAR) of a landmark "granting lot" as set forth in this table. Wherever there may be an inconsistency between any provision in Section 74-79 and the table, the provisions of the table shall apply.
MAXIMUM FLOOR AREA RATIOS AND FLOOR AREA BONUSES BY ZONING DISTRICT
BASIC AND MAXIMUM FLOOR AREA RATIOS (FAR)
Means for Achieving Permitted FAR Levels on a Zoning Lot | Special Lower Manhattan District except within Core or Subdistrict | Hist-oric & Comm Core | South Street Seaport Subdistrict and all waterfront zoning lots | |||||||
R8 | C6-4 | C5-3 C5-5 C6-9 | M1-4 | C5-5 | C2-8 | C4-6 | C6-2A | C5-3 | C6-9 | |
Basic maximum FAR | 6.021 6.53 | 10.02,3,4 | 10.04 15.02,3 | 2.02 6.53 | 10.04 15.02,3 | 2.02 3.43 10.04 | 3.42,3,4 | 6.02 6.024 6.53 | 10.04 15.02,3 | 15.0 |
Maximum as-of-right floor area bonus for public plazas | NA | 2.0 | 3.0 | NA | NA | NA | NA | NA | NA | NA |
Maximum as-of-right floor area bonus for Inclusionary Housing (23-90) | NA | 2.0 | NA | NA | NA | NA | NA | NA | NA | NA |
Maximum FAR with as-of-right floor area bonuses | 6.021 6.53 | 12.0 | 18.0 | 2.02 6.53 | 15.0 | 2.02 3.43 10.04 | 3.4 | 6.02 6.024 6.53 | 15.0 | 15.0 |
Maximum floor area bonuses by authorization or special permit: mass transit station improvements and covered pedestrian spaces | NA | 2.08 | 3.0 | NA | 3.0 | 2.09 | NA | NA | 3.09 | 3.09 |
Maximum FAR with as-of-right, authorization or special permit floor area bonuses | 6.021 6.53 | 12.010 | 18.0 | 2.02 6.53 | 18.0 | 12.0 | 3.4 | 6.02 6.024 6.53 | 18.0 | 18.0 |
Development rights (FAR) of a landmark lot for transfer purposes (74-79) | NA | 10.0 | 15.05 18.06 | NA | 15.0 | NA | NA | NA | NA | NA |
Maximum total FAR of designated receiving sites in South Street Seaport Subdistrict (91-60) | NA | NA | NA | NA | NA | NA | 3.4 | 8.02 | 21.67 | 21.67 |
Maximum FAR with transferred development rights from landmark zoning lot and as-of-right and authorization or special permit floor area bonuses | 6.021 6.53 | 14.010 | 21.6 | 2.42 7.83 | 21.6 | NA | 3.4 | 8.02 | 21.67 | 21.67 |
1 maximum floor area ratio and minimum open space ratio shall be determined in accordance with the provisions of Article II, Chapter 3
2 for a commercial or, where permitted, manufacturing use
3 for a community facility use
4 for a residential use
5 if receiving lot is located in a zoning district with a basic maximum FAR of less than 15
6 if receiving lot is located in a zoning district with a basic maximum FAR of 15
7 maximum FAR for receiving lots less than 30,000 square feet
8 for zoning lots utilizing a floor area bonus pursuant to Section 66-51 (Additional Floor Area for Mass Transit Station Improvements), the maximum floor area bonus shall be 2.4 FAR
9 only pursuant to Section 66-51
10 for zoning lots utilizing a floor area bonus pursuant to Section 66-51, the maximum FAR may be increased through a combination with Inclusionary Housing, in accordance with the provisions of such Section
In C5-3, C5-5 and C6-9 Districts, the residential floor area ratio of a zoning lot may be increased to 12.0, provided that recreation space, for the residential occupants of the building on such zoning lot, is provided in an amount not less than 16.25 square feet for each dwelling unit or a total area of at least 5,000 square feet, whichever is greater.
Such recreation space may be located at any level, including a roof, and shall:
- be restricted to residential occupants of the building and their guests for whom no admission or membership fees may be charged;
- be directly accessible from a lobby or other public area served by the residential elevators;
- be landscaped, including trees or shrubbery, except where covered or developed with recreational facilities and seating areas;
- contain not less than 500 square feet of continuous area on a single level with no dimension of less than 15 feet; and
- have not less than 50 percent of the area open from its lowest level to the sky. The remaining portion may be roofed and up to 50 percent of its perimeter may be enclosed. In no event may more than 25 percent of the required recreation space be fully enclosed. All enclosures shall be transparent except when located within the building. Covered areas shall contain recreation facilities or seating areas.
A copy of requirements (a) through (e) shall be permanently posted in a conspicuous place within each recreation space.
The maximum permitted floor area on a zoning lot may be increased, in accordance with the following regulations, where a public plaza is provided that meets the requirements of Section 37-70 (PUBLIC PLAZAS):
(a) A floor area bonus for a public plaza shall only be permitted for a development or enlargement that is located:
(1) outside the Historic and Commercial Core;
(2) outside the South Street Seaport Subdistrict; or
(3) beyond 50 feet of a street line of a designated street, except in C6-4 Districts, on which:
(i) retail continuity is required, pursuant to Section 91-41 (Regulations for Designated Retail Streets); or
(ii) street wall continuity is required, pursuant to the regulations for Type 1 or Type 2A street walls pursuant to Section 91-31 (Street Wall Regulations).
(c) Within a C6-4 District, paragraph (a)(3) of this Section shall not apply to the location of a development or enlargement. However, a floor area bonus for a public plaza shall be permitted, provided that such public plaza is located beyond 50 feet of the designated streets referenced in paragraph (a)(3).
(b) For each square foot of a public plaza, the basic maximum floor area permitted by Section 91-22 (Floor Area Increase Regulations) may be increased, in C6-4 Districts, by six square feet, to a maximum floor area ratio of 12.0 and, in C5-3, C5-5 and C6-9 Districts, by 10 square feet, to a maximum floor area ratio of 18.0.
(c) When a public plaza that meets the requirements for a floor area bonus is located on a zoning lot divided by a district boundary, the bonusable floor area may be credited to either portion of the zoning lot, notwithstanding the location of the public plaza or the date of the creation of the zoning lot. The amount of bonusable floor area permitted on either portion of the zoning lot shall not exceed the maximum amount of floor area permitted on such portion if it were a separate zoning lot subject to all other provisions of Article VII, Chapter 7.
Within the Special Lower Manhattan District, the City Planning Commission may grant the following special permits for increased floor area in accordance with the provisions of this Section.
In C5-3, C5-5, C6-4 and C6-9 Districts within the Special Lower Manhattan District, except within the South Street Seaport Subdistrict, the City Planning Commission may grant, by special permit, a floor area bonus for a commercial, community facility or mixed building that provides covered pedestrian space on a zoning lot, in accordance with the provisions of Section 74-87 (Covered Pedestrian Space).
The total additional floor area permitted on the zoning lot shall not exceed the maximum amount permitted in the underlying district by the provisions of Sections 91-21 (Maximum Floor Area Ratio) and 91-22 (Floor Area Increase Regulations).
For all buildings or other structures in the Special Lower Manhattan District, the height and setback regulations of the underlying districts are superseded by the regulations of this Section.
The height of all buildings or other structures shall be measured from curb level.
For the purposes of applying the street wall regulations of this Section, developments shall include alterations and enlargements that change the height, width or location of a street wall.
All portions of buildings or other structures located above the maximum base heights specified in paragraph (a) of this Section shall provide a setback in accordance with the regulations of Section 91-32 (Setback Regulations).
- Within the Special District, the maximum base height shall be 85 feet or 1.5 times the width of the street upon which the building fronts, whichever is greater, except as provided for the following types of street wall regulations:
- Street wall regulations: Type 1
For developments that front upon a street indicated as "Type 1" on Map 2 (Street Wall Continuity Types 1, 2A, 2B and 3) in Appendix A, street walls shall extend along the entire street frontage of the zoning lot not occupied by existing buildings to remain, to a minimum base height of 150 feet or the height of the building, whichever is less. The maximum base height shall be 250 feet. - Street wall regulations: Type 2A
For developments that front upon a street indicated as "Type 2A" on Map 2 in Appendix A, street walls shall extend along such entire street frontage of the zoning lot not occupied by existing buildings to remain, to a minimum base height of 85 feet or the height of the building, whichever is less. The maximum base height shall be 150 feet. - Street wall regulations: Type 2B
For developments that front upon a street indicated as "Type 2B" on Map 2 in Appendix A, street walls shall extend along at least 60 percent of such street frontage of the zoning lot not occupied by existing buildings to remain, to a minimum base height of 85 feet or the height of the building, whichever is less. The maximum base height shall be 150 feet. - Street wall regulations: Type 3
For developments that front upon a street indicated as "Type 3" on Map 2 in Appendix A, street walls shall extend along the entire street frontage of the zoning lot not occupied by existing buildings to remain, to a minimum base height of 60 feet, five stories, or the height of the building, whichever is less. The maximum base height shall be 85 feet or 1.5 times the width of the street upon which the building fronts, whichever is greater. - Street wall regulations: Type 4
For developments that front upon a street within the Historic and Commercial Core, indicated as "Type 4" on Map 3 (Street Wall Continuity Types 4 and 5) in Appendix A, the maximum base height shall be 100 feet. - Street wall regulations: Type 5
For developments that front upon a street indicated as "Type 5" on Map 3 in Appendix A, no setbacks are required for any portion of a building.
- Street wall regulations: Type 1
- For developments that front upon a street indicated as "Type 1" or "Type 2A," at least 70 percent of the aggregate width of street walls shall be located on such street line. For developments that front upon a street indicated as "Type 2B," at least 60 percent of the aggregate width of street walls shall be located within 10 feet of such street line. For developments that front upon a street indicated as "Type 3," at least 70 percent of the aggregate width of street walls shall be located within 10 feet of such street line. The remaining 30 percent of the aggregate width of street walls may be located beyond such street lines in compliance with:
- the outer court regulations of Article II, Chapter 3, for residential portions of buildings;
- the outer court regulations of Article II, Chapter 4, for all other portions of buildings; or
- the requirements of Section 37-50 where such areas are pedestrian circulation spaces.
- When a building fronts on two intersecting streets for which different maximum base heights are specified, the higher maximum base height may wrap around to the street with the lower maximum base height for a distance along the street line of 100 feet. However, "Type 5" street walls shall not be permitted to wrap around to the intersecting street.
- Arcades and sidewalk widenings that meet the design standards of Section 37-53 (Design Standards for Pedestrian Circulation Spaces) shall be permitted along any street indicated as "Type 1," "Type 2A" or "Type 3," pursuant to paragraphs (a), (b) or (c) of this Section, provided such arcade or sidewalk widening extends along the entire block frontage or abuts another arcade, existing on August 27, 1998, of equal width and height or another sidewalk widening of equal width. In such case, the street wall requirements for paragraph (b) of this Section shall be measured from the permitted arcade or sidewalk widening.
In accordance with the provisions of Section 91-31 (Street Wall Regulations), setbacks are required for any portion of a building or other structure that exceeds the maximum base heights specified for the applicable street in Section 91-31.
Required setbacks shall be provided at a height not lower than any minimum base height or 60 feet where none is specified and not higher than any maximum base height specified for the applicable street in Section 91-31. The depth of the setback shall be determined by the lot area of the zoning lot, as shown in the following table:
REQUIRED DEPTH OF SETBACKS
Lot area of zoning lot | Minimum setback depth |
Less than 15,000 square feet | 10 feet |
15,001 to 30,000 square feet | 15 feet |
Greater than 30,000 square feet | 20 feet |
For "Type 1" and "Type 2A and 2B" street walls, the required setbacks shall be measured from the street line.
For "Type 3" street walls, the required setbacks shall be measured from a line drawn at or parallel to the street line so that at least 70 percent of the aggregate width of street walls of the building at the minimum base height are within such line and the street line.
For all other street walls, the required setbacks shall be measured from a line drawn at, or parallel to, the street line so that at least 50 percent of the aggregate width of street walls of the building at the minimum base height are within such drawn line and the street line. However, setbacks are not required for street walls fronting upon the major portion of a bonused public plaza.
For buildings within the Historic and Commercial Core as shown on Map 1 in Appendix A, any building or portion of a building may be located within the required setback area beneath a sky exposure plane that rises from a height of 100 feet above the street line over the zoning lot at a vertical distance of six to a horizontal distance of one.
Above the maximum base height specified in Section 91-31 (Street Wall Regulations), up to a height of 300 feet, the maximum lot coverage of any zoning lot shall be 65 percent. Above a height of 300 feet, the maximum lot coverage of any zoning lot shall be 50 percent.
However, within the Historic and Commercial Core, above the maximum base height specified in Section 91-31, up to a height of 300 feet, the maximum lot coverage of any zoning lot shall be 75 percent. Above a height of 300 feet, the maximum lot coverage of any zoning lot shall be 60 percent.
For buildings fronting on more than one street where different maximum base heights are specified, the maximum lot coverage regulations specified in this Section shall apply at horizontal planes at heights corresponding to the different maximum base heights. The lot coverage at the level of the lowest plane shall apply to the portion of a zoning lot located beyond 100 feet from any street with a higher maximum base height. The lot coverage at the level of each subsequent higher plane shall apply to the portion of the zoning lot located beyond 100 feet from any street with a higher maximum base height, and shall also include those portions of the zoning lot where lower base heights apply. The highest horizontal plane shall be established over the entire zoning lot.
For any portion of a building above a height of 300 feet, the maximum horizontal dimension, measured in any direction, shall not exceed 175 feet

Diagram of Maximum Horizontal Dimension
(91—34)
The City Planning Commission, by special permit, may modify:
- the street wall requirements and minimum base heights of Section 91-31 (Street Wall Regulations);
- the setback requirements of Section 91-32; and
- where such zoning lots contain buildings existing on December 15, 1961, that exceed a height of 300 feet, the lot coverage regulations of Section 91-33 and the maximum horizontal dimension set forth in Section 91-34 (Maximum Horizontal Dimension for Tall Buildings), provided such modifications are limited to that portion of the development or enlargement between 300 and 325 feet in height, and provided the lot coverage of such portion does not exceed 55 percent.
In order to grant such special permit, the Commission shall find that:
- such modifications will result in a site plan consistent with existing scale and streetscape patterns;
- such modifications will ensure a harmonious relationship between the development or enlargement and the surrounding area;
- such street wall modifications will enhance pedestrian circulation by providing pedestrian amenities that relieve sidewalk congestion;
- such setback, lot coverage or horizontal dimension modifications will not unduly obstruct access to light and air to surrounding streets and properties; and
- such setback, lot coverage or horizontal dimension modifications will result in a built form that maintains an appropriate relationship between tower and base portions of the development or enlargement.
The Commission may prescribe appropriate conditions and safeguards to minimize adverse effects on the character of the surrounding area.
The use regulations of this Section, inclusive, shall apply to buildings developed after August 27, 1998, and to buildings enlarged on the ground floor level after August 27, 1998.
For any development or enlargement fronting on the ground floor level of designated retail streets, as shown on Map 4 in Appendix A, the street frontage of the building shall be allocated exclusively to the uses set forth in Section 91-12 (Uses on Designated Retail Streets). However, uses located within lobby or entrance spaces, subway station improvements or pedestrian circulation spaces that do not front on the ground floor level of the street shall be in accordance with the provisions for permitted uses of the underlying district.
Where the street frontage occupied by all building entrances is 20 feet or more in width, the amount of street frontage occupied by lobby space, entrance space and building entrance recesses shall not exceed, in total, 40 linear feet or 25 percent of the building's total street frontage, whichever is less, exclusive of any frontage occupied by a relocated subway stair or the entrance area to a bonused subway station improvement.
Storefronts for permitted ground floor uses shall be no more than 10 feet from the street line or, where an arcade is provided with supporting columns at the street line, no more than 10 feet from the supporting columns.
Access to each permitted establishment or use shall be provided directly from the designated retail street, as shown on Map 4 in Appendix A. Where there is more than one entrance to the establishment or use from the designated retail street, direct access shall be provided via the entrance with the greatest aggregate clear opening width.
At least 50 percent of the street wall surface of each permitted establishment or use shall be glazed with clear untinted transparent material and not more than 50 percent of such transparent surface shall be painted or obstructed with signs.
For the purposes of this glazing requirement, the street wall surface of each permitted establishment shall be measured from the floor to the height of the ceiling or 14 feet above grade, whichever is less.
Within the boundaries of the Special Lower Manhattan District, all developments or enlargements constructed after August 27, 1998, on zoning lots of at least 5,000 square feet that contain more than 70,000 square feet of new floor area shall provide pedestrian circulation space on such zoning lot in accordance with the provisions of Section 37-50.
Pedestrian circulation space shall not be required if any of the following conditions exist:
- the zoning lot is entirely occupied by a building of no more than one story in height;
- the zoning lot is an interior lot fronting on a wide street with less than 80 feet of street frontage;
- the zoning lot is an interior or through lot fronting on a street or streets with Type 1, Type 2A, Type 2B, Type 3, Type 4 or Type 5 street wall regulations, as set forth in paragraph (a) of Section 91-31 (Street Wall Regulations);
- the zoning lot is a through lot and both street frontages are less than 25 feet in length; or
- the zoning lot is located in a C6-2A or C6-9 District within the South Street Seaport Subdistrict.
Where a development or enlargement is constructed on a zoning lot that contains at least 5,000 square feet of lot area and fronts on a sidewalk containing a stairway entrance or entrances into a subway station, the existing entrance or entrances shall be relocated from the street onto the zoning lot. The new entrance or entrances shall be provided in accordance with the provisions of Section 37-40 (OFF-STREET RELOCATION OR RENOVATION OF A SUBWAY STAIR). A relocated or renovated subway stair may be counted as pedestrian circulation space in accordance with the provisions of Section 37-50.
The subway stations where such improvements are required are listed in the following table and shown on Map 7 (Subway Station Improvement Areas) in Appendix A.
STATION | LINE |
Bowling Green | Lexington Avenue |
Broad St | Nassau Street |
Broadway-Nassau Street | 8th Avenue |
Fulton Street | Nassau Street/Broadway-7th Ave/ Lexington Ave |
Brooklyn Bridge-City Hall | Lexington Avenue |
Chambers Street | Nassau Street |
Chambers Street | Broadway-7th Avenue |
Chambers Street | 8th Avenue |
Park Place | Broadway-7th Avenue |
World Trade Center | 8th Avenue |
City Hall | Broadway-60th Street |
Cortlandt Street-WTC | Broadway-7th Avenue |
Cortlandt Street | Broadway-60th Street |
Rector Street | Broadway-7th Avenue |
Rector Street | Broadway-60th Street |
Wall Street | Broadway-7th Avenue |
Wall Street | Lexington Avenue |
Whitehall Street-South Ferry | Broadway-7th Avenue/ Broadway-60th Street |
The off-street parking regulations of Article 1, Chapter 3 (Comprehensive Off-street Parking and Loading Regulations in the Manhattan Core) and the loading regulations of the underlying districts apply to the Special Lower Manhattan District, except as supplemented or modified by the provisions of this Section.
Accessory off-street parking spaces shall be permitted for dwelling units in non-residential buildings erected prior to January 1, 1977, or portions thereof, that are converted to residential use, provided:
- no more than 200 spaces or a number of spaces equal to 20 percent of the number of dwelling units in the converted building, whichever is less, shall be permitted;
- no curb cut shall be permitted on any street where the converted building has a street frontage of 40 feet or less;
- no portion of any such parking facility shall be more than 23 feet above curb level;
- no exhaust vents shall open onto any street or public park or publicly accessible open space, and no portion of the parking facility, other than entrances and exits, shall be visible from adjoining zoning lots, streets or parks; and
- all such parking facilities shall be provided on the same zoning lot as the residential uses to which they are accessory, except as otherwise provided in Section 91-511 (Authorization for off-site parking facilities for converted buildings).
The City Planning Commission may authorize accessory residential off-site parking spaces for non-residential buildings erected prior to January 1, 1977, or portions thereof, that are converted to residential use, to be provided in a fully enclosed building on a zoning lot within the Special Lower Manhattan District other than the zoning lot that contains the residential use, provided the Commission finds that:
- such accessory off-site parking spaces are conveniently located in relation to the residential use, and in no case further than 600 feet from the zoning lot containing the residential use;
- such location of the accessory off-site parking facility will permit better site planning for the building converted to residential use;
- that such accessory off-site parking facility shall contain parking spaces accessory only to residential uses; and
- such parking facility complies with findings in paragraphs (c)(1), (c)(2), (c)(3) and (c)(5) of Section 13-45 (Special Permits for Additional Parking Spaces).
The number of accessory off-site parking spaces authorized in accordance with the provisions of this Section shall be recorded on the certificates of occupancy, temporary and permanent, for both the residential use and the accessory off-site parking facility.
All curb cuts shall be prohibited on streets indicated on Map 5 in Appendix A, except that:
- The Commissioner of Buildings may approve a curb cut where there are no alternative means of access to required off-street loading berths from other streets bounding the zoning lot.
- The City Planning Commission may authorize curb cuts for loading berths, provided:
- such loading berths are adjacent to a fully enclosed maneuvering area on the zoning lot;
- such maneuvering area is at least equal in size to the area of the loading berth; and
- there is adequate space to permit head-in and head-out truck movements to and from the zoning lot.The City Planning Commission may refer such applications to the Department of Transportation for comment.
- The City Planning Commission may authorize curb cuts for accessory parking for residences, provided such curb cuts:
- will not create or contribute to serious traffic congestion or unduly inhibit vehicular and pedestrian movement; and
- will not interfere with the efficient functioning of required pedestrian circulation spaces, or public transit facilities.
The City Planning Commission may refer such applications to the Department of Transportation for comment.
No curb cuts may be approved or authorized on Battery Place, Broad Street, Broadway, Liberty Street west of Broadway, Park Row South or Wall Street.
In addition, for zoning lots with frontage on streets where curb cuts are prohibited, the Commissioner of Buildings may waive required off-street loading berths pursuant to the provisions set forth in Section 13-35 (Modification of Loading Berth Requirements).
Where a curb cut is approved or authorized pursuant to this Section, the maximum width of a curb cut, including splays, shall be 15 feet for a street with one-way traffic and 25 feet for a street with two-way traffic.
- For zoning lots containing Use Group 10A department stores and Use Group 6B offices, where not more than 78,000 square feet of such office use is changed to department store use, the following modifications may be made provided that the Chairperson of the City Planning Commission certifies to the Department of Buildings that the conditions in paragraphs (b), (c), (d) and (e) of this Section have been met:
- waiver of accessory off-street loading berths required for such department store use;
- waiver of existing required accessory off-street loading berths when such waiver is necessary to provide an improved goods receiving and in-store transport system; and
- exemption of existing loading berth floor space from the definition of floor area as set forth in Section 12-10 when such floor space will be used for such improved goods receiving and in-store transport system.
- A plan for curb side deliveries shall have been approved by the Department of Transportation, as part of the improved goods receiving and in-store transport system for the department store use. Such plan shall be based upon a traffic study prepared by a qualified professional and a scope of work, both of which have been approved by the Department of Transportation, establishing that the plan for curbside deliveries shall not create or contribute to serious traffic congestion or unduly inhibit vehicular or pedestrian movement and shall not interfere with the efficient functioning of nearby public transit facilities;
- At least one additional freight elevator and an aggregate of at least 6,000 square feet of staging area for loading and deliveries, exclusive of the area occupied by elevators, shall be provided on the zoning lot to be used for the improved goods receiving and in-store transport system for such department store use, as depicted on a site plan;
- In the event that any existing loading berth floor space is to be exempted from the definition of floor area as set forth in Section 12-10, such floor space shall be used for the improved goods receiving and in-store transport system; and
- A Declaration of Restrictions shall have been executed, in a form acceptable to the Department of City Planning, binding upon the owners and its successors and assigns, and providing for maintenance and use of the staging areas and additional elevators for the improved goods receiving and in-store transport system, as well as continued compliance with the plan for curbside deliveries and the site plan. Such declaration shall be filed and recorded in the Office of the City Register of the City of New York against the lots comprising the zoning lot. Receipt of proof of recordation in a form acceptable to the Department shall be a precondition to the issuance of this certification, and the recording information shall be included on any temporary or final certificate of occupancy for any building or portion thereof, issued after the recording date.
The regulations of Section 91-60, et seq., relating to special regulations for the South Street Seaport Subdistrict are applicable only in the South Street Seaport Subdistrict. The boundaries of the South Street Seaport Subdistrict are shown on Map 1 (Special Lower Manhattan District) and Map 6 (South Street Seaport Subdistrict) in Appendix A. The regulations of Section 91-60, et seq., supplement or modify the regulations of this Chapter applying in general to the South Street Seaport Subdistrict area of the Special Lower Manhattan District.
In order to preserve and protect the character of the South Street Seaport Subdistrict and to implement the provisions of the Brooklyn Bridge Southeast Urban Renewal Plan, as amended, special controls and incentives are provided.
The provisions of Article VI, Chapter 2 (Special Regulations in the Waterfront Area), shall apply to waterfront zoning lots within the South Street Seaport Subdistrict. The provisions of paragraph (c) of Section 74-792 (Conditions and limitations) concerning the transfer of development rights from landmark sites in C5-3, C5-5, C6-6, C6-7 or C6-9 Districts shall not apply in the South Street Seaport Subdistrict.
For purposes of this Section, matter in italics is defined in Section 12-10 (DEFINITIONS) or within this Section.
Development rights
Within the South Street Seaport Subdistrict, the basic maximum permitted floor area for a granting lot shall be that which is allowed by the applicable district regulations as if such granting lot were undeveloped, and shall not include any additional floor area bonuses for public plazas, arcades or any other form of floor area increase, whether as-of-right or by special permit. Streets located within the Subdistrict that have been closed or discontinued in whole, part or whose air space has been closed or discontinued pursuant to Section E15-3.0 of the Administrative Code, or its successor, shall have attributed to such closed area or closed air space the basic maximum permitted floor area allowed within the underlying zoning district within which such streets are situated. The lot area of a closed or discontinued volume of air space shall be measured by the area of the bed of the street lying below and within such closed or discontinued volume.
Granting lot
Within the South Street Seaport Subdistrict, a "granting lot" is a zoning lot or a closed or discontinued portion of a street or air space over a street which is identified as a granting lot, as identified on Map 6 (South Street Seaport Subdistrict) in Appendix A, upon which development is regulated by contract, lease, covenant, declaration or otherwise to assure compliance with the purposes of this Subdistrict and from which development rights may be transferred. Such zoning lots and closed portions of streets or air space over streets are identified on the map of the transfer areas (Map 6) as Parcels 6, 7 and 9 and the adjacent hatched street areas.
Person
Within the South Street Seaport Subdistrict, a "person" is an individual, corporation (whether incorporated for business, public benefit or not-for-profit purposes or otherwise), partnership, trust firm, organization, other association or any combination thereof.
Receiving lot
Within the South Street Seaport Subdistrict, a "receiving lot" is a zoning lot identified on the map of transfer areas (Map 6 in Appendix A) to which development rights may be added. Such "receiving lots" are identified on the map as Parcels 1, 2, 8, 15, 16, 20, 21 and 22.
Street
- A street, as defined in Section 12-10; or
- a way, designed or intended for general public circulation and use, that:
- performs the pedestrian circulation functions usually associated with a way shown on the City Map;
- remains open and unobstructed from the at-grade circulation level to the sky, except for public facilities customarily located on a street shown on the City Map, or those facilities permitted to be located on a street shown on the City Map, including without limitation, transitory fixtures or objects unattached to the real property encompassed by such way; and
- is a designated pedestrian way, pursuant to Section 91-68.
A street, as defined in paragraph (b) of this Section, shall satisfy and apply to all references to streets provided elsewhere in the Zoning Resolution.
The South Street Seaport Subdistrict transfer areas map, shown hereto as Map 6 in Appendix A, sets forth each granting lot and receiving lot within the Subdistrict.
Within the South Street Seaport Subdistrict, development rights from each of the granting lots may be conveyed or otherwise disposed of:
- directly to a receiving lot; or
- to a person for subsequent disposition to a receiving lot, all in accordance with the provisions of this Subdistrict, except that with respect to zoning lots located on Parcels 6, 7 and 9, as identified on Map 6 (South Street Seaport Subdistrict) in Appendix A, only those development rights in excess of the larger of the following conditions may be so conveyed or otherwise disposed of:
- an amount equal to the product of the lot area of each of such zoning lots multiplied by 5.0; or
- the total floor area of all existing buildings on any such zoning lots.
The City Planning Commission shall certify such initial transfer from the granting lots. Any person may convey its interest in all or a portion of such development rights to another person but such development rights may only be used on a receiving lot.
Within the South Street Seaport Subdistrict, all or any portion of the development rights transferred from a granting lot may be added to the floor area of all or any one of the receiving lots in an amount not to exceed the ratio of 10 square feet of development rights to each square foot of lot area of such receiving lot, except that with respect to a receiving lot having a lot area of less than 30,000 square feet, the total floor area ratio shall not exceed 21.6. However, if a receiving lot is located in a C4-6 District, the total floor area ratio shall not exceed 3.4 and if a receiving lot is located in a C6-2A District, the total floor area ratio shall not exceed 8.02. Development rights transferred to a receiving lot may be applied to a mixed building to increase the floor area of the residential, commercial and/or community facility portions of such building so that the maximum floor area for such building may be increased by the aggregate of development rights so transferred. In no event shall the residential floor area ratio exceed 12.0.
The City Planning Commission shall certify that any zoning lot that utilizes such transferred development rights conforms to this Section and, for those receiving lots within the Urban Renewal Area, to the regulations and controls of the Urban Renewal Plan.
Within the South Street Seaport Subdistrict, for any zoning lot located in a C6-2A District, the underlying height and setback regulations shall apply, except the maximum building height shall be 120 feet. No minimum base height shall apply, and the depth of a required setback along a narrow street shall be at least 10 feet. No lot coverage regulations shall apply to corner lots. Furthermore, the provisions of Article II, Chapter 8 (The Quality Housing Program), shall not apply.
In the South Street Seaport Subdistrict, the City Planning Commission may authorize:
- the alteration of any public amenity, open or enclosed, for which a floor area bonus has been granted, provided that the Commission finds that such modifications improve the intended public purpose of the amenity; or
- the elimination or reduction of an existing public amenity, open or enclosed, for which a floor area bonus has been granted, provided that a new or improved public amenity, open or enclosed, is supplied elsewhere on, or within proximity to, the zoning lot, and the Commission finds that:
- the public amenity to be eliminated no longer serves its original purpose; and
- the proposed new or improved public amenity will provide a greater public benefit than the amenity to be eliminated or reduced and will better serve the purposes of the Special Lower Manhattan District; and
- the modification of the applicable height, setback, lot coverage and distance between buildings requirements for any development or enlargement on a designated receiving lot that will incorporate transferred development rights, provided the Commission finds that the modifications:
- provide an appropriate distribution of bulk on the zoning lot;
- permit adequate light and air to the development or enlargement and adjoining properties as well as the surrounding streets; and
- will not impair the use and desirability of any public amenity that may be created or improved under the provisions of paragraph (b) of this Section.
If a receiving lot contains an existing building, such authorization shall incorporate any previous height and setback or other bulk modifications, granted prior to December 11, 2001, by the Board of Standards and Appeals, for such existing building.
The Commission may prescribe appropriate conditions and safeguards in connection with the grant of such authorization.
Within the South Street Seaport Subdistrict, the City Planning Commission may modify, by special permit, the height and setback and lot coverage regulations of Section 91-30, provided that:
- either of the following conditions have been met:
- that the developer has obtained negative easements limiting the height of future development or enlargement to 85 feet or less on any adjoining zoning lots which are contiguous or would be contiguous to said zoning lot but for their separation by a street or street intersection, and such easements are recorded against such adjoining zoning lots by deed or written instrument. The Commission shall consider the aggregated areas of said zoning lot and the adjoining lots subject to such negative easements and the extent to which they achieve future assurance of light and air in determining the maximum permitted coverage. In no event shall such coverage exceed 80 percent of the zoning lot on which the development or enlargement will be located; or
- that the lot coverage for that portion of a development or enlargement below 300 feet may be increased to a maximum of 80 percent when additional development rights have been purchased and converted to increased lot coverage. The maximum percentage of lot coverage on such receiving lot shall be the sum of 65 percent plus one-half of one percent for every .10 by which the total floor area ratio on such receiving lot would exceed a floor area ratio of 21.6, provided that the development or enlargement on such receiving lot has achieved a minimum floor area ratio of 18.0;
- In order to grant such special permit, the Commission shall make the following findings:
- the location of the development or enlargement and the distribution of bulk will permit adequate light and air to surrounding streets and properties;
- any modification of height and setback will provide for better distribution of bulk on the zoning lot; and
- such special permit will aid in achieving the general purposes and intent of the Subdistrict.
The Commission may prescribe appropriate conditions and safeguards to minimize adverse effects on the character of the surrounding area.
For any zoning lot which was the subject of application N130058 ZCM, the hours of operation set forth in paragraph (a) of Section 62-71 (Operational Requirements) may be extended to allow public access up to 24 hours per day, and the provisions of paragraph (a)(3) of Section 62-654 (Signage) shall be modified to require any such extended hours of public access, as may change over time, to be included on the required signage. The provisions of paragraph (a)(4) of Section 62-654 shall not apply where 24 hour access is allowed. The provisions of paragraph (b) of Section 62-71 requiring rules of conduct for the waterfront public access area to be established with the Department of Parks and Recreation, and other provisions of this Chapter requiring a maintenance and operation agreement pursuant to Section 62-74 (Requirements for Recordation), shall not apply so long as a legal instrument acceptable to the Chairperson, in all other respects consistent with the provisions of Section 62-74, has been executed and recorded, setting forth rules of conduct and maintenance and operations requirements.
Within the South Street Seaport Subdistrict, at the time of transfer of development rights from a granting lot, there shall be recorded in the Office of the Register of the City of New York, and indexed against such granting lot from which floor area is removed, an instrument removing such floor area and prohibiting construction on such zoning lot of any building or other structure which would contain floor area in excess of that still available to the zoning lot after deducting the floor area removed, such prohibition to be non-cancelable for 99 years; and at the time of the addition of development rights to a receiving lot as provided in Section 91-65, there shall be recorded in the Office of the Register of the City of New York, and indexed against such receiving lot to which floor area is added, an instrument transferring the floor area to the receiving lot benefited and identifying the granting lot (by tax block and lot number and description) from which the floor area has been removed. A certified copy of such instruments shall be submitted to the City Planning Commission upon recordation.
Within the South Street Seaport Subdistrict, the volume situated above the subsurface streets shown on the City Map, and listed in this Section are designated pedestrian ways and are governed by paragraph (b) of the definition of street as set forth in Section 91-62 (Definitions):
- Fulton Street, between Water and South Streets
- Water Street, between Fulton and Beekman Streets
- Front Street, between Fulton and Beekman Streets, and between John and Fulton Streets
- South Street (the 18-foot-wide strip located on the northwesterly side), between Beekman and John Streets.
In addition, the designated pedestrian ways referenced in paragraphs (a), (b) and (c) of this Section may be considered a single zoning lot for purposes of the definition of large-scale general development in Section 12-10 (Definitions).
Within the area bounded by South Street, the southerly edge of Pier 9, the U. S. Pierhead Line and the northerly edge of Pier 14, which, for the requirements of this Section, shall be deemed to be a single zoning lot, the City Planning Commission may, by special permit, permit modification of the bulk regulations, other than floor area ratio applicable to the zoning lot, and may modify or waive the requirements of Section 62-50 (GENERAL REQUIREMENTS FOR VISUAL CORRIDORS AND WATERFRONT PUBLIC ACCESS AREAS), in accordance with the provisions of this Section.
The special permit shall be subject to the condition that the property owner, principal lessee or licensee of property owner has entered into an agreement with the Department of Parks and Recreation to operate and maintain the publicly accessible areas in accordance with Section 62-70 (MAINTENANCE AND OPERATION REQUIREMENTS FOR WATERFRONT PUBLIC ACCESS AREAS). For purposes of this Section, such publicly accessible areas shall be deemed "waterfront public access areas."
In granting any such modifications, the Commission shall find that:
- any modification of height and setback regulations results in an appropriate distribution of permitted bulk on the piers;
- no buildings or other structures shall unduly obstruct the visual corridor bounded by the prolongation of the northern and southern street lines of Wall Street seaward to the U. S. Pierhead Line;
- any modification will not unduly impede surface traffic and will minimize possible vehicular/pedestrian conflicts in the surrounding area;
- that the seaward end of all such piers is unobstructed to the greatest extent feasible so as to maximize views northward and southward;
- the development plan for such area includes an appropriate amount of publicly-accessible open space which shall incorporate appropriate design features that serve the needs of the local area, including but not limited to landscaping, lighting and seating; and
- the development plan is integrated with existing and proposed nearby development.
The Commission may prescribe additional appropriate conditions and safeguards to minimize adverse effects on the character of the waterfront and surrounding area.
Developments or enlargements in the former Special Greenwich Street Development District built prior to August 27, 1998, will continue to be governed by the regulations in effect at the time of issuance of the building permit and can only be modified or altered by Sections 91-71 through 91-73, inclusive.
The City Planning Commission may authorize modifications of certain provisions of the former Special Greenwich Street Development District, eliminated on August 27, 1998, that mandated public amenities, as follows:
- For any mandatory or elective public amenities or improvements built pursuant to the regulations of the former Special District that resulted in an increase in the basic maximum floor area ratio or an increase in the adjusted basic maximum floor area ratio, the Commission may authorize:
- the alteration of the amenity or improvement, provided that the Commission finds that such modifications improve the intended public purpose of the amenity;
- the elimination of the amenity or improvement, provided that the Commission finds that the intended public purpose is no longer useful or desirable and a new public amenity or improvement is supplied, as permitted pursuant to this Chapter, that generates the same or higher amount of bonusable floor area; or
- in the case of an amenity or improvement built in excess of the requirements necessary to generate the bonus floor area at the time of development or enlargement, the elimination of such portion of the amenity not tied to the bonus floor area, provided that the Commission finds that such portion is no longer useful or desirable.
- For any mandatory or elective public amenities or improvements built pursuant to the regulations of the former Special District that did not result in an increase in the basic maximum floor area ratio, the Commission may authorize the elimination or alteration of the amenity or improvement if it finds that the intended public purpose is no longer useful or desirable.
- No mandatory or elective public amenity or improvement built pursuant to the regulations of the former Special District shall be eliminated or reduced in size, without a corresponding reduction in the floor area of the building or the substitution of equivalent complying area for such amenity elsewhere on the zoning lot, in accordance with the provisions of paragraph (a)(2) of this Section, except by special permit of the Commission, subject to a finding that the proposed change will provide a greater public benefit in light of the public amenity's purpose and the purposes of the Special Lower Manhattan District.
However, the open pedestrian bridge spanning Greenwich Street between Liberty and Cedar Streets may be eliminated, without recourse to the Commission, where the pedestrian access provided between the required elevated public pedestrian circulation systems is no longer useful or desired.
The Commission may prescribe appropriate conditions and safeguards in connection with the grant of such authorization.
The City Planning Commission, by special permit, may allow:
- the unmapped air space above the approaches to the Brooklyn Battery Tunnel to be considered a single zoning lot and may allow the development or enlargement of a building on such unmapped air space, where the zoning lot for such development or enlargement shall include only that portion of the area above the approaches to the Brooklyn Battery Tunnel and contiguous areas of land or property that are covered by a permanent platform and not designated as approaches to the Brooklyn Battery Tunnel.
- the unmapped air space above the approaches to the Brooklyn Battery Tunnel, the unmapped air space above Joseph P. Ward Street and the at-grade parcels bounding the northern street line of Joseph P. Ward Street to be deemed a single zoning lot, and in connection therewith:
- such zoning lot shall generate floor area only from such at-grade parcels and only those portions of the unmapped air space above the approaches to the Brooklyn Battery Tunnel covered by a permanent platform or building existing on November 15, 2007;
- no floor area shall be generated from the unmapped air space above Joseph P. Ward Street; and
- unused floor area generated from those portions of the unmapped air space above the approaches to the Brooklyn Battery Tunnel covered by a permanent platform or building existing on November 15, 2007, shall only be located on the at-grade parcels bounding the northern street line of Joseph P. Ward Street and shall only be used for residential floor area.
Notwithstanding any of the foregoing, the use and occupancy of the unmapped air space above the approaches to the Brooklyn Battery Tunnel and of the at-grade parcel bounding the northern street line of Joseph P. Ward Street and shown on the City Map, as amended October 3, 1946, as an approach to the Brooklyn Battery Tunnel by the New York State Triborough Bridge and Tunnel Authority, may be continued and in effect as set forth in Resolutions of the former New York City Board of Estimate and as otherwise permitted by law.
The at-grade parcels of the zoning lot bounding the northern street line of Joseph P. Ward Street shall be considered a through lot bounded by Washington Street and West Street from its lowest level to the sky, and only such at-grade parcels shall be used to determine compliance with applicable bulk regulations other than floor area and lot area regulations.
For purposes of this paragraph, (b), the at-grade parcels bounding the northern street line of Joseph P. Ward Street shall mean:
the at-grade parcel bounding the northern street line of Joseph P. Ward Street and shown on the City Map, as amended October 3, 1946, as an approach to the Brooklyn Battery Tunnel; and
the at-grade parcel bounding the northern line of said parcel.
In order to grant such special permit, the Commission shall find that adequate access and street frontage to one or more streets is provided; and the streetscape, site design and location of building entrances of the proposed development or enlargement will contribute to the overall improvement of pedestrian circulation within the surrounding area.
The Commission may prescribe appropriate conditions and safeguards to protect and minimize any adverse effects on the character of the surrounding area.
A zoning lot containing a development, or portion thereof, on a waterfront zoning lot, may be located within the volume above the upper limiting plane of the Battery Park Underpass/South Street, when such volume is eliminated, discontinued and closed. That portion of the zoning lot that lies above the Battery Park Underpass/South Street shall not be considered lot area for the purpose of computing maximum floor area; however, such portion shall be considered lot area for all other purposes of this Resolution.
The following regulations shall apply to arcades and publicly accessible open areas existing on June 21, 2016, located within the Water Street Subdistrict as shown on Map 8 in Appendix A of this Chapter except for the plaza that was the subject of special permit application CP-20518, approved by the City Planning Commission on November 27, 1968.
For the purposes of this Section, inclusive, "arcade" shall refer to an arcade or through block arcade provided in accordance with the provisions of Sections 12-10 (DEFINITIONS) and 37-80 (ARCADES), or any other arcade that generated a floor area bonus as evidenced by plans approved by the Department of Buildings.
A horizontal enlargement permitted by Sections 91-83 (Retail Uses Within Existing Arcades), inclusive, or 91-841 (Authorization for retail uses within existing arcades) shall not be included as floor area, and such additional area shall not result in a reduction of the permitted floor area.
No arcade may be eliminated or reduced in size pursuant to paragraphs (a) or (d) of Section 33-124 (Existing public amenities for which floor area bonuses have been received). In lieu thereof the following provisions shall apply: Sections 91-83, 91-841 and, as applicable, Section 91-85 (Special Permit for Enlargements of 7,500 Square Feet or Greater).
For any zoning lot that was the subject of application C810325ZSM, C810506ZSM or C841070ZSM, a certification pursuant to Section 91-83 or an authorization pursuant to Section 91-841 shall not result in a departure from the findings and conditions specified in the applicable special permit, and such certification or authorization shall not require modification of the applicable special permit unless such a modification is required pursuant to a related restrictive declaration. For the zoning lot that was the subject of application C810325ZSM, the existing through block arcade shall not be eliminated, but may be modified in size and configuration provided that the standards for through block arcades set forth in Section 12-10 are met.
Public events may take place within a publicly accessible open area or arcade pursuant to the provisions of Section 91-81 (Events Within Public Access Areas). Publicly accessible tables, chairs, shade umbrellas and heating lamps may be located within a publicly accessible open area or arcade pursuant to the provisions of Section 91-82 (Amenities Within Public Access Areas). An outdoor cafe may be located within an arcade pursuant to Section 91-821 (Certification for outdoor cafes within arcades).
A horizontal enlargement of the ground floor and second floor levels may be permitted within arcades, or portions thereof, located within Area A in Map 9 of Appendix A of this Chapter pursuant to the provisions of Section 91-83, and within Area B pursuant to the provisions of Section 91-841. In addition, a horizontal enlargement of 7,500 square feet or greater shall also require a special permit pursuant to Section 91-85. For the purposes of calculating the total area of the horizontal enlargement that is subject to the special permit, the aggregate area of the horizontal enlargement permitted by prior certifications pursuant to Sections 91-83 and 91-837 (Subsequent design changes) and prior authorizations pursuant to Section 91-841 shall be included in such calculation, except the area of an indoor public space shall be excluded from such calculation. In no event shall an enlargement be permitted within arcades, or portions thereof, located within Area C on Map 9 in Appendix A of this Chapter.
The provisions of Article III, Chapter 7 restricting the temporary placement or storage of event-related amenities or equipment within a publicly accessible open area or arcade shall be modified by the provisions of this Section. The temporary placement or storage of event-related equipment or amenities in accordance with the provisions of this Section shall not constitute a design change pursuant to the provisions of Sections 37-625 or 91-837.
Events including, but not limited to, farmers' markets, holiday markets, concerts and performances, art and cultural exhibitions and festivals are permitted within all publicly accessible open areas and arcades. The utilization of a publicly accessible open area or arcade for the promotion of products or services shall not itself qualify as an event permitted under this Section.
Events shall be open to the public, provide free and unticketed admission and only be permitted to use amplified sound between the hours of 9:00 a.m. and 10:00 p.m. All publicly accessible open areas and arcades shall continue to be publicly accessible at all times. Event-related amenities and equipment shall be considered temporary permitted obstructions provided that sufficient circulation space connecting all streets and building entrances exists. All publicly accessible open areas and arcades shall be restored to their approved condition within 24 hours of the conclusion of an event.
The storage of equipment or materials outside of an event's scheduled hours, excluding time required for set up and clean up, shall not be permitted within a publicly accessible open area or arcade. However, for events taking place over multiple days or weeks, large temporary equipment that requires assembly and will be actively used during the event, such as stages, kiosks and sound and video entertainment systems, may remain in the publicly accessible open area or arcade outside of the event's scheduled hours.
At least 30 days prior to the scheduled date of an event, notification shall be given to the local Community Board, local Council Member and Borough President of the nature, size and duration of the event.
The provisions of Article III, Chapter 7 restricting the placement of tables, chairs, shade umbrellas and heating lamps within a publicly accessible open area or arcade shall be modified by the provisions of this Section. The placement of tables, chairs, shade umbrellas or heating lamps in accordance with the provisions of this Section, inclusive, shall not constitute a design change pursuant to the provisions of Sections 37-625 or 91-837.
Publicly accessible tables and chairs, as well as shade umbrellas and heating lamps, shall be permitted obstructions within a publicly accessible open area or arcade, provided that such obstructions comply with the provisions of Section 91-822 (Requirements for furnishings), as applicable. Tables, chairs, shade umbrellas and heating lamps provided pursuant to this Section may be used by the public without restriction. Outdoor cafes may be placed within an arcade by certification pursuant to Section 91-821 (Certification for outdoor cafes within arcades).
An outdoor cafe may be permitted within an arcade upon certification by the Chairperson of the City Planning Commission to the Commissioner of Buildings that, in addition to the provisions of this Section, the provisions of Section 91-822 (Requirements for furnishings) are met. An outdoor cafe that is permitted by this Section shall be a permanently unenclosed restaurant or eating or drinking place, which may have waiter or table service.
No portion of an outdoor cafe that is permitted by this Section may extend into a publicly accessible open area except where an open air cafe has been permitted by a certification pursuant to Section 37-73 (Kiosks and Open Air Cafes).
In order to certify that the proposed modification to an existing arcade is consistent with the provisions of this Section, the applicant shall submit to the Chairperson a site plan and other detailed plans demonstrating that the proposed obstructions within the existing arcade and, where applicable, pursuant to paragraph (a)(2) of Section 91-822, the adjacent publicly accessible open area, will comply with the provisions of this Section. The placement of publicly accessible tables and chairs within a publicly accessible open area pursuant to paragraph (a)(2) of Section 91-822 shall not constitute a design change pursuant to the provisions of Section 37-625.
All plans for arcades or other publicly accessible open areas that are the subject of a certification pursuant to this Section shall be filed and duly recorded in the Office of the City Register of the City of New York, indexed against the property in the form of a legal instrument, in a form satisfactory to the Chairperson, providing notice of the certification of the arcade, pursuant to this Section. The filing and recording of such instrument shall be a precondition to certification. The filing and recording information shall be included on any temporary or final certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
The following provisions shall apply to all furnishings, including tables, chairs, shade umbrellas and heating lamps, permitted by Section 91-82 (Amenities Within Public Access Areas) and Section 91-821 (Certification for outdoor cafes within arcades).
- Size, location and other requirements
- Requirements for all furnishings
All furnishings shall be moveable. Permanent fixtures may be installed in the ground of a publicly accessible open area or arcade for the purposes of supporting shade umbrellas or heating lamps provided that such fixtures are flush-to-grade.
No furnishings shall be permitted within five feet of any building entrance, nor shall they be permitted within any required circulation paths. - Additional requirements for outdoor cafes located within arcades
Where an outdoor cafe is provided pursuant to Section 91-821, a minimum of four tables and 16 chairs shall be provided and made available to the public without restriction, which may be located within an arcade or within a publicly accessible open area and shall be outside of the permitted cafe boundary.
Outdoor cafes shall be located at the same elevation as the adjoining sidewalk area or publicly accessible open area, except that they may be located no more than six inches below or on a platform no more than six inches above such adjoining sidewalk area or publicly accessible open area. The border of the outdoor cafe shall be permanently marked in accordance with the applicable standards for open air cafes set forth in paragraph (b) of Section 37-73.
Fences, planters, walls, fabric dividers or other barriers that separate outdoor cafe areas from other portions of the arcade, adjacent sidewalks or publicly accessible open areas shall be prohibited. No kitchen equipment shall be installed within an outdoor cafe.
Litter receptacles shall be provided in accordance with the standards for public plazas set forth in Section 37-744. - Circulation requirements for outdoor cafes located within arcades
For arcades with a depth of 10 feet or less, as measured from the column face furthest from the street line or publicly accessible open area to the building wall fronting on such street line or publicly accessible open area, an unobstructed path not less than three feet wide shall be provided. For arcades with a depth greater than 10 feet, as measured from the column face furthest from the street line or publicly accessible open area to the building wall fronting on such street line or publicly accessible open area, such unobstructed pedestrian way shall be increased to at least six feet. For through block arcades, an unobstructed pedestrian way, except for approved doorways, of at least eight feet shall be provided connecting each street on which the through block arcade fronts.
- Requirements for all furnishings
- Operation
- Requirements for all tables and chairs
Except as otherwise provided in paragraph (b)(2) of this Section, tables, chairs, shade umbrellas and heating lamps may be stored or secured within an arcade between the hours of 9:00 p.m. and 7:00 a.m., but may not be stored or secured within a publicly accessible open area. - Additional requirements for outdoor cafes located within arcades
Publicly accessible tables and chairs that are required by paragraph (a)(2) of this Section may not be removed or secured while the cafe is in active use.
All furnishings within the boundary of an outdoor cafe, including tables, chairs, shade umbrellas, bussing stations and heating lamps, shall be completely removed from the arcade when the outdoor cafe is not in active use, except that tables and chairs may remain in such arcade if they are unsecured and may be used by the public without restriction.
- Requirements for all tables and chairs
A horizontal enlargement of the ground floor and second floor levels within an arcade located within Area A on Map 9 in Appendix A of this Chapter may be permitted upon certification by the Chairperson of the City Planning Commission to the Commissioner of Buildings that such enlargement complies with the provisions of this Section, and the following conditions are met:
- the horizontal enlargement meets the requirements of Section 91-831 (Ground floor requirements);
- a compensating amenity is provided pursuant to the provisions of Section 91-832 for plaza improvements, Section 91-834 for indoor public spaces, or Section 91-835 for alternative improvements; and
- the additional requirements of Section 91-836, as applicable.
For zoning lots with one or more publicly accessible open area, unless an alternative improvement has been identified in Section 91-835, an improvement to all publicly accessible open areas pursuant to the provisions of Section 91-832 shall be required as the compensating amenity required by condition (b) of this Section, and a certification for design changes pursuant to Section 37-625 shall not be required. Where a publicly accessible open area was improved and is fully compliant with a prior certification pursuant to Section 37-625 that was granted before January 19, 2016, the further improvement of such publicly accessible open area shall not be required.
The provision of a compensating amenity as part of a prior certification pursuant to this Section or a prior authorization pursuant to Section 91-841 (Authorization for retail uses within existing arcades) may satisfy the requirements of condition (b) of this Section for a compensating amenity.
As part of the certification, a horizontal enlargement of the ground floor level may be permitted within the area between a street wall and an arcade that did not generate a floor area bonus prior to June 21, 2016. The provisions of Section 91-831 (Ground floor requirements) shall not apply to such portion of the horizontal enlargement.
As part of the certification, a horizontal enlargement of the ground floor level may be permitted along existing building walls that do not face an arcade, and such enlargement shall not occupy any publicly accessible open area. The locational requirements of paragraph (a)(1) of Section 91-831 and the frontage prohibitions of paragraph (b)(1)(ii) of Section 91-831 shall apply to such enlargement. Where an enlargement is located adjacent to a publicly accessible open area, the use and transparency requirements of Section 91-831 for new building walls facing a publicly accessible open area shall apply.
For a horizontal enlargement of 7,500 square feet or greater, a special permit pursuant to Section 91-85 shall also be required. For the purposes of calculating the total area of the horizontal enlargement that is subject to the special permit, the aggregate area of the horizontal enlargement permitted by prior certifications pursuant to this Section and Section 91-837 (Subsequent design changes) and prior authorizations pursuant to Section 91-841 shall be included in such calculation, except the area of an indoor public space shall be excluded from such calculation.
Where any portion of the arcade remains open and accessible, such remaining arcade area shall maintain a minimum level of illumination of not less than five horizontal foot candles between sunset and sunrise. Any non-transparent portion of a building wall between columns that fronts on such arcade area shall be treated with artwork, planting or decorative material. Additional requirements for transparency in paragraph (c)(3) of Section 91-831 may apply.
The provisions of this Section shall apply to the street wall of the ground floor and second floor level enlargement. For the purposes of this Section, a building wall that faces a publicly accessible open area or through block arcade shall also be considered a street wall, and the provisions of this Section for new building walls fronting on a publicly accessible open area shall also apply to new building walls fronting on a through block arcade, except as otherwise specified. The City Planning Commission may authorize a modification of the provisions of this Section pursuant to Section 91-842 (Authorization to modify design requirements).
- Location of enlargement
- Location of new building walls
All new building walls shall extend to the full height of the arcade. New building walls may only be located between the column face closest to an existing street wall and the column face furthest from an existing street wall or the street wall location of the floor above, except that new building walls within an existing through block arcade that do not face a street may extend past the column face furthest from the existing street wall provided that the standards for through block arcades set forth in Section 12-10 (DEFINITIONS) and all other provisions of this Section are met. New building walls within an existing through block arcade that do not face a street shall not be required to extend for the full height of the through block arcade. - Length of new building walls
An enlargement shall extend for the full length of the street wall, except for the locations specified on Map 9 in Appendix A of this Chapter and except if a corner arcade that adjoins the Water Street street line and another street line or publicly accessible open area is provided in accordance with the provisions of paragraph (c) of Section 37-53 (Design Standards for Pedestrian Circulation Spaces) which may provide a clear path 10 feet wide. However, an enlargement shall not be required along the length of the street wall occupied by an existing parking or loading entrance. Where an enlargement within an arcade extends along two or more street walls, the enlargement shall also include the area where the arcade areas intersect, except as otherwise provided in this Section, and the location of new building walls in such area shall be subject to the provisions of paragraph (a)(1) of this Section.
- Location of new building walls
- Permitted uses within an enlargement
- Requirements for all frontages
- Retail uses
The street frontage or frontage along a publicly accessible open area of the enlarged portion of the ground floor level shall be allocated exclusively to indoor public spaces that are provided in accordance with the provisions of Section 91-834 or the uses permitted by Sections 91-111 (Additional uses in C5 Districts) and 91-12 (Uses on Designated Retail Streets), except that Use Groups 5A, 7A, 7B, 8B, 9A, 10A, 12A, 12B, or 12C shall not be permitted. However, bicycle rental or repair shops and studios for art, music, dancing or theater shall be permitted. Residential uses shall be limited to lobbies permitted by paragraph (c)(2) of this Section.
All uses permitted by this paragraph shall occupy a height no less than that of the ground floor level, and shall occupy a depth no less than that of the enlargement. - Parking, loading and mechanical equipment
No garage entrances, driveways, parking spaces or loading berths shall be permitted within an enlargement. No exhaust vents or mechanical equipment shall be permitted on any new building wall unless such exhaust vents are more than 15 feet above the level of the curb. - Maximum street wall width
On the ground floor portion of an enlargement for the following Use Group 6 uses: the maximum street wall width of a bank or loan office shall not exceed 30 feet; and the maximum street wall width of a drug store shall not exceed 50 feet.
- Retail uses
- Additional use requirement for a publicly accessible open area or through block arcade
At least 50 percent of the total frontage of all new building walls fronting on a publicly accessible open area or through block arcade, excluding such frontage occupied by building lobbies, shall be occupied by retail or service establishments permitted by paragraph (b)(1) of this Section. As an alternative, the amount of frontage required by this paragraph for occupancy by retail or service establishments may be partially or fully located along existing building walls fronting on the publicly accessible open area or through block arcade and the transparency requirements of paragraph (c)(3) of this Section shall apply to such frontage.
Libraries, museums and art galleries are permitted uses that may front on a publicly accessible open area. Banks shall not be a permitted use on any publicly accessible open area or through block arcade. Uses required by this paragraph shall be directly accessible from the publicly accessible open area or through block arcade.
- Frontage
- Number of establishments
Along the longest street wall of the ground floor level enlargement, at least two establishments permitted by paragraph (b) of this Section shall be provided on the ground floor level. Frontage that is solely dedicated to access a use on a level other than the ground floor level shall not constitute an establishment for the purposes of this paragraph. - Access, entrances and lobbies
The street wall frontage of an enlarged portion of the ground floor level may be occupied by the primary entrance for the principal use of the building, provided that such primary entrance shall not exceed a street wall width of 50 feet along Water Street, or, along other streets, a street wall width of 40 feet, or 25 percent of the aggregate width of street wall along such street frontage, whichever is less.
For a primary entrance that fronts on a publicly accessible open area, such entrance shall occupy a minimum frontage length of 20 feet or a length equal to the distance between the two closest columns adjacent to the publicly accessible open area, whichever is less. A primary entrance for the principal use of the building may be located along a through block arcade or indoor public space provided in accordance with Section 91-834 (Indoor public spaces), but may only occupy a maximum frontage length of 25 feet.
Where more than 50 percent of the length of the enlargement is occupied by a primary entrance permitted by this paragraph, retail or service establishments with an aggregate frontage length equal to at least 50 percent of the length of the enlargement shall be required along new or existing building walls along the same street frontage as the enlargement, and the transparency requirements of paragraph (c)(3) of this Section shall apply to such frontage along existing building walls. - Transparency and flood resilience
The ground floor level street wall between existing columns shall be glazed with transparent materials, which may include show windows, transom windows or glazed portions of doors, except for certain uses set forth in Section 37-31 (Applicability). Such transparent materials shall occupy at least 70 percent of the surface area of such ground floor level street wall between a height above grade of two feet and 14 feet or the height of the ground floor ceiling, whichever is lower.
Where the use located within the ground floor level enlargement fronts on an arcade that remains open and accessible, the length of such frontage shall be glazed with transparent materials in accordance with the provisions of this paragraph.
Permanent fixtures for temporary flood control devices and associated emergency egress systems that are assembled prior to a storm and removed thereafter and are affixed to a column may obstruct any transparent portion of a new building wall. Such permanent fixtures may be considered a transparent portion of a new building wall. Additionally, such permanent fixtures shall be encased in a decorative material. Temporary flood control devices and associated emergency egress systems shall be permitted in front of any new building wall for a reasonable period of time prior to and after a storm event, as determined by the Department of Buildings.
- Number of establishments
A publicly accessible open area shall be improved in full accordance with the provisions of Section 37-70 (PUBLIC PLAZAS) as modified by this Section, and as further modified by Section 91-833 (Special regulations for plazas less than 40 feet in depth) for publicly accessible open areas with a maximum depth of less than 40 feet, as measured perpendicular to any street line. Subsequent design changes to any publicly accessible open area improved pursuant to the provisions of such Sections may only be permitted pursuant to Section 91-837. The City Planning Commission may authorize a modification of the provisions of this Section and Section 91-833 pursuant to Section 91-842 (Authorization to modify design requirements).
- For the purposes of applying the provisions of this Section, any portion of the publicly accessible open area occupied by a garage entrance, driveway, loading berth or gratings for electrical vaults may be excluded from the calculation of the total area or total street frontage of the publicly accessible open area. Such area shall remain open and accessible to the public at all times.
- The area dimension requirements of Section 37-712, the locational restrictions of Section 37-713, the orientation restrictions of Section 37-714 and the requirements for major and minor portions of public plazas set forth in Sections 37-715 and 37-716, respectively, shall not apply.
- The through block public plaza provisions of Section 37-717 that require a setback along any building wall or walls that adjoin a through block public plaza or through block portion of a publicly accessible open area shall not apply.
- The sidewalk frontage provisions of Section 37-721 shall be modified as follows:
- the requirements of paragraph (a) may be reduced to the minimum extent necessary to allow existing walls or structures within such area to remain, provided that such walls or structures do not increase in height or length along the street frontage, and all portions of the publicly accessible open area are accessible from a street, arcade or other portion of the publicly accessible open area.
- paragraph (b) shall be modified to allow planters with bounding walls that exceed a height of two feet that are permitted by paragraph (g) of this Section to be located in such area.
- for corner public plazas, where there is a change in elevation permitted by paragraph (e) of this Section for the area within 15 feet of the intersection of any two or more streets on which the publicly accessible open area fronts, such area shall not be required to be at the same elevation as the adjoining public sidewalk, but must be free of obstructions except as may otherwise be provided in paragraph (d)(1) of this Section.
- The provisions of Section 37-722 (Level of plaza) shall be modified to permit any elevation of the publicly accessible open area existing on June 21, 2016, to remain.
- The provisions of Section 37-726 (Permitted obstructions) shall be modified as follows:
- paragraph (c) shall allow awnings above retail and service establishments that do not project into the publicly accessible open area more than three feet when measured perpendicular to the building facade. There shall be no limitation on the area or height of an awning, but in no event shall an awning for a retail or service establishment contain vertical supports.
- paragraph (d) shall allow garage entrances, driveways or loading berths fronting on a publicly accessible open area and existing on June 21, 2016, to remain, provided that they are separated from the remainder of the publicly accessible open area by a barrier sufficient to substantially conceal these facilities and any vehicles therein when viewed from any point in the publicly accessible open area. A building trash storage facility may be accessed or serviced through the portion of a publicly accessible open area that is occupied by a garage entrance, driveway or loading berth.
- The provisions of Section 37-742 (Planting and trees) may be modified where the Chairperson of the City Planning Commission has been provided with documentation sufficient to establish that subsurface conditions do not allow the required soil depth for shrubs or trees to be provided below-grade or within a planter with bounding walls no higher than 18 inches in height above an adjacent walking surface or the highest adjacent surface where the bounding wall of such planter adjoins two or more walking surfaces with different elevations. A raised planter may be provided with bounding walls up to three feet for shrubs, or 3 feet, 6 inches for trees, provided that fixed seating with backs is integrated into the planter for at least 50 percent of the perimeter of the planter that is adjacent to a walking surface. If such planter, or any portion thereof, is located within ten feet of a street line, fixed seating with backs shall be integrated into at least 75 percent of the perimeter of the planter that is adjacent to a walking surface. Where it is demonstrated that no required trees can be planted flush-to-grade or planted at grade within planting beds with no raised curbs or railings, the Chairperson may allow all trees to be planted within raised planters.
- The calculation of the minimum number of entry plaques required by paragraph (a) of Section 37-751 (Public space signage systems) may be modified for publicly accessible open areas that occupy more than one street frontage to alternatively require a minimum of one entry plaque at each street frontage of the publicly accessible open area, and to further require one additional entry plaque at each street frontage that measures 80 feet or more in length.
- The provisions of paragraphs (a) and (d) of Section 37-753 (Accessory signs) shall not apply. Each establishment fronting on the publicly accessible open area shall be permitted to have one or more signs with an aggregate area not to exceed the product of 12 square feet and the length of the establishment along the publicly accessible open area in linear feet, divided by 40 linear feet. In no event shall a sign exceed 16 square feet in area. Signs may be affixed to the building wall or to awnings, or may project no more than 18 inches when measured perpendicular to the building facade, provided that such sign is located a minimum of 10 feet above the level of the publicly accessible open area.
- The provisions of paragraphs (a) and (b) of Section 37-76 (Mandatory Allocation of Frontages for Permitted Uses) shall not apply. The provisions of Section 91-831 (Ground floor requirements) shall apply to all new building walls fronting on the publicly accessible open area, and the following shall also apply:
- the use requirements of paragraph (b)(1) of Section 91-831 shall apply to all new establishments located along existing building walls fronting on a publicly accessible open area; and
- the provisions of paragraph (c) of Section 37-76 for existing building walls that are non-transparent shall apply except for frontage occupied by active loading and parking entrances.
- The provisions of Section 37-78 (Compliance) shall be modified as follows:
- paragraph (a) shall be modified to provide that no permit shall be issued by the Department of Buildings for any change to a publicly accessible open area without certification by the Chairperson of the City Planning Commission of compliance with the provisions of this Section and Sections 91-833 or 91-837, as applicable; and
- paragraph (b) shall be modified to require that the periodic compliance report shall document compliance with the provisions of Section 37-70 as modified by this Section and, as applicable, Section 91-833, and that such report shall also be provided to the local Council Member.
A publicly accessible open area with a maximum depth less than 40 feet measured perpendicular to any street line shall be improved in full accordance with the provisions of Section 37-70 (PUBLIC PLAZAS) as modified by Section 91-832 (Plaza improvements) and as further modified by this Section. Where a publicly accessible open area may be considered a corner public plaza, the maximum depth shall be measured from a street line to a street wall. The City Planning Commission may authorize a modification of the provisions of this Section pursuant to Section 91-842 (Authorization to modify design requirements).
- The provisions of Section 37-721 (Sidewalk frontage) shall not apply. In lieu thereof, the provisions of this paragraph (a) shall apply to the area of the publicly accessible open area located within 10 feet of a street line or sidewalk widening line.
- At least 40 percent of such area shall be free of obstructions and, in addition:
- to facilitate pedestrian access at least 40 percent of the frontage along each street line or sidewalk widening line of the publicly accessible open area shall be free of obstructions; and
- such unobstructed access area shall extend to a depth of 10 feet measured perpendicular to the street line. The width of such access area need not be contiguous provided that no portion of such area shall have a width of less than five feet measured parallel to the street line, and at least one portion of such area shall have a width of at least eight feet measured parallel to the street line.The requirement of this paragraph for unobstructed access may be reduced to the minimum extent necessary to allow existing walls or structures within such area to remain provided that such walls or structures do not increase in height or length along the street frontage, and all portions of the publicly accessible open area are accessible from a street, arcade or other portion of the publicly accessible open area.
- In the remaining 60 percent or more of such area, the provisions of paragraph (b) of Section 37-721 shall apply, except that no more than 40 continuous linear feet of any street frontage occupied by a publicly accessible open area may be obstructed. Furthermore, planters with bounding walls that exceed a height of two feet that are permitted by paragraph (g) of Section 91-832 may be located in such area.
- For corner public plazas, the requirements of this paragraph (a) shall apply separately to each street frontage, and the area within 10 feet of the intersection of any street and Water Street or Wall Street shall be at the same elevation as the adjoining public sidewalk, except where there is a change in elevation permitted by paragraph (e) of Section 91-832, and such area shall be free of obstructions except as may otherwise be provided in paragraph (a)(1) of this Section.
- The provisions of Section 37-723 (Circulation paths) shall be modified so that the required circulation path of at least eight feet clear width shall be located adjacent to the street wall and shall extend for at least 80 percent of the length of such street wall. Where there are multiple street walls, the provisions of this paragraph shall apply separately to each frontage. In addition to the obstructions that are permitted within circulation paths, moveable tables and chairs, fixed seating and planting beds not exceeding six inches above any adjacent walking surface shall also be considered permitted obstructions provided that an unobstructed path of at least five feet wide is provided.
Where an open air cafe pursuant to Section 37-73 (Kiosks and Open Air Cafes) is provided adjacent to a building wall, such open air cafe may occupy a portion of the required circulation path provided that there is an unobstructed clear path of at least six feet wide between the building wall and any furnishings of the open air cafe. The unobstructed path shall be included in the calculation of the area occupied by the open air cafe. - The provisions of Section 37-741 (Seating) that require seating within 15 feet of the street line shall not apply to street frontages that measure less than 40 feet in length.
- The provisions of Section 37-742 (Planting and trees) shall be further modified as follows:
- For publicly accessible open areas with an area less than 2,000 square feet, the number of required trees shall be reduced to two, and only one tree shall be required to be planted flush-to-grade or planted at grade within planting beds with no raised curbs or railings, except as may be modified by paragraph (g) of Section 91-832.
- The total area of required planting beds may not be concentrated within one continuous planter or planting bed, except when a publicly accessible open area has an area of 1,000 square feet or less.
- The provisions of Section 37-746 (Drinking fountains) shall be modified to require only publicly accessible open areas containing an area of 2,000 square feet or more to provide a minimum of one drinking fountain.
Indoor public spaces are enclosed, climate-controlled areas on a zoning lot intended for public use and enjoyment. The standards contained within this Section are intended to serve the same purposes outlined for public plazas in Section 37-70. The City Planning Commission may authorize a modification of the provisions of this Section pursuant to Section 91-842 (Authorization to modify design requirements).
- Indoor public spaces shall contain an area of not less than 2,000 square feet and have a minimum width and depth, at any point, of 20 feet. Indoor public spaces shall be located on the ground floor level, shall be directly accessible from all streets or publicly accessible open areas that the space fronts, and shall extend, at a minimum, for the full height of the ground floor level.
- Indoor public spaces shall be fully enclosed, and the transparency requirements of paragraph (c) of Section 91-831 (Ground floor requirements) shall apply to all street walls or building walls facing a publicly accessible open area. The space shall be heated or air-conditioned, and the standards for heating, ventilating and air-conditioning shall be at least equal to those of the lobby for the principal use of the building.
- Public access to the indoor public space shall be provided, at a minimum, between the hours of 6:00 a.m. to 12:00 a.m. The hours of access shall be included on all required entry plaques and information plaques in accordance with the provisions of Section 37-751 (Public space signage systems) and paragraph (i) of this Section.
- The provisions of Sections 37-718 (Paving), 37-722 (Level of plaza), 37-728 (Standards of accessibility for persons with disabilities), 37-744 (Litter receptacles), 37-745 (Bicycle parking), 37-746 (Drinking fountains), 37-748 (Additional amenities), 37-752 (Prohibition signs), 37-753 (Accessory signs) and 37-77 (Maintenance) shall apply.
- The provisions of Section 37-723 (Circulation paths) for through block public plazas shall apply to through block arcades except as otherwise provided in Section 91-821 (Certification for outdoor cafes within arcades) when a cafe is provided. Trees planted flush-to-grade that measure less than four caliper inches at the time of planting, as permitted by paragraph (h) of this Section, shall not be considered permitted obstructions within circulation paths.
- The provisions of paragraphs (a) and (b) of Section 37-726 (Permitted obstructions) shall apply. A kiosk shall be a permitted obstruction provided that the requirements of paragraph (a) of Section 37-73 (Kiosks and Open Air Cafes) are met. A certification pursuant to Section 37-73 shall not be required to locate a kiosk within an indoor public space. A cafe permitted by certification pursuant to Section 91-821 shall be considered a permitted obstruction within an indoor public space and may not occupy more than 20 percent of the indoor public space area.
- The provisions of Section 37-741 for seating shall apply, except as modified as follows:
- The requirements for seating within 15 feet of a street line shall not apply.
- All of the linear seating capacity may be in moveable seats. Any moveable seats that are provided must remain in the indoor public space during the hours of operation.
- The requirement that seats that face walls must be a minimum of six feet from such wall shall only apply to fixed seating.
- The requirements of Section 37-742 for planting and trees shall apply, except that the surface area of any vertical planting may be included in the calculation of the total area of planting beds that are provided, and trees shall not be required.
- Public space signage shall be provided in accordance with the provisions of Section 37-751, except as modified as follows:
- An information plaque shall be provided at each point of pedestrian entry to the indoor public space. Information plaques for through block arcades shall also include lettering stating "PUBLIC ACCESS TO ____ STREET" indicating the opposite street to which the through block connection passes and which lettering shall not be less than three inches in height and located not more than three inches away from the public space symbol. Furthermore, a minimum of one additional information plaque shall be provided within the indoor public space.
- Paragraph (c) shall not apply.
- All indoor public spaces shall be illuminated with a minimum level of illumination of not less than five horizontal foot candles (lumens per foot) throughout the space. The requirements of Section 37-743 for a lighting schedule, a diagram of light level distribution and electrical power shall apply.
- The use requirements of paragraph (b) and the lobby requirements of paragraph (c)(2) of Section 91-831 shall apply to all building walls fronting on an indoor public space that do not face a street or publicly accessible open area. The provisions of paragraph (c) of Section 37-76 for new or existing building walls that are non-transparent shall apply.
- The provisions of Section 37-78 (Compliance) shall be modified as follows:
- paragraph (a) shall not apply; and
- paragraph (b) shall be modified to require that the periodic compliance report shall document compliance with the provisions of Section 37-70 as modified by this Section, and that such report shall also be provided to the local Council Member.
Subsequent design changes to any indoor public space that was subject to the provisions of this Section may only be permitted pursuant to Section 91-837 (Subsequent design changes).
A permanent amenity other than the improvement of an existing publicly accessible open area pursuant to the provisions of Section 91-832 or the provision of an indoor public space pursuant to the provisions of Section 91-834 may be provided for the properties listed in this Section. The City Planning Commission may authorize an improvement not listed in this Section pursuant to Section 91-843 (Authorization to modify requirements for alternative improvements).
Building Address | Required Alternative Improvement |
175 Water Street | Area C on Map 9 in Appendix A of this Chapter, the open area along John Street and the open area along Front Street with a minimum depth of 15 feet measured perpendicular to the Front Street street line shall be improved in accordance with the provisions of Sections 91-832 and 91-833. Such open area and remaining arcade area shall be considered one contiguous public space and shall be accessible to the public at all times. |
100 Wall Street | Maintenance of Manahatta Park between Water Street and Front Street for the life of the building. |
110 Wall Street | Maintenance of Manahatta Park between Front Street and South Street for the life of the building. |
- Legal requirements
All plans for arcades, publicly accessible open areas, required open areas, and indoor public spaces that are the subject of a certification pursuant to Section 91-83 (Retail Uses Within Existing Arcades) shall be filed and duly recorded in the New York County Office of the City Register of the City of New York, indexed against the property in the form of a legal instrument, in a form satisfactory to the Chairperson of the City Planning Commission, providing notice of the certification pursuant to Section 91-83. The filing and recording of such instrument shall be a precondition to certification. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date. Where compensating amenity required by condition (b) of Section 91-83 is located on the same zoning lot as an enlargement, no temporary or final certificate of occupancy shall be issued for such enlargement until the compensating amenity has been substantially completed in accordance with the approved plans, as certified by the Department of City Planning to the Department of Buildings.
Where a compensating amenity is located within a street or public park pursuant to Section 91-835 (Alternative improvements), the commitment to provide or maintain such compensating amenity shall be duly recorded in the form of a signed declaration of restrictions, including a maintenance agreement with the Department of Parks and Recreation or other relevant agency, indexed against the zoning lot, binding the owners, successors and assigns. Such declaration or maintenance agreement may require security in the form of a bond or letter of credit to ensure that the compensating amenity is maintained in accordance with the declaration or maintenance agreement. The form and content of the legal instrument shall be satisfactory to the Chairperson, and the filing of such instrument in the New York County Office of the City Register shall be a precondition to certification. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date. Modifications to the declaration required by this paragraph may only be allowed upon approval by the Chairperson. - Existing approvals by the Board of Standards and Appeals
Where a zoning lot is subject to a variance or special permit that was granted by the Board of Standards and Appeals, the application pursuant to Section 91-83 shall be referred for thirty (30) days to the Board of Standards and Appeals who shall certify to the Department of City Planning whether such application would not result in a departure from the findings and conditions specified in the original approval. - Community Board review
No earlier than the date on which the application for certification pursuant to Section 91-83 is filed, a copy of the application shall be submitted by the applicant to the affected Community Board and local Council Member for 45 days to review said application. The Chairperson shall not issue a certification for an application during the Community Board review period, unless the Community Board has submitted to the Chairperson comments regarding such proposal or informed the Chairperson that the Community Board has no comments.
Design changes to any publicly accessible open area, required open area or indoor public space previously improved pursuant to the provisions of Sections 91-832 (Plaza improvements) or 91-834 (Indoor public spaces) may only be made upon certification by the Chairperson of the City Planning Commission that such changes would result in a publicly accessible open area or indoor public space that is compliant with the Section under which it was previously approved. As part of the certification, a horizontal enlargement on the ground floor level may be permitted along existing building walls that face the publicly accessible open area and do not face an arcade, but such enlargement shall not occupy any publicly accessible open area. The locational requirements of paragraph (a)(1) of Section 91-831 (Ground floor requirements) and the use and transparency requirements of Section 91-831 for new building walls facing a publicly accessible open area shall apply. The legal requirements of paragraph (a) of Section 91-836 shall apply.
The City Planning Commission may authorize a horizontal enlargement of the ground floor and second floor levels within an arcade located within Area B on Map 9 in Appendix A of this Chapter. In order to grant an authorization, the Commission shall find that:
- the requirements of Section 91-831 (Ground floor requirements) are met;
- a compensating amenity is provided pursuant to the provisions of Section 91-832 for plazas, Section 91-834 for indoor public spaces or Section 91-835 for alternative improvements;
- sufficient unobstructed space exists adjacent to the proposed enlargement to facilitate pedestrian circulation; and
- the enlargement will maintain a visual or physical connection to Water Street from another street, public park or publicly accessible open area.
As part of the authorization, the Commission may modify the requirements for the location of new building walls of paragraph (a) of Section 91-831 (Ground floor requirements).
For zoning lots with one or more publicly accessible open area, unless an alternative improvement has been identified in Section 91-835, an improvement to all publicly accessible open areas pursuant to the provisions of Section 91-832 shall be required as the compensating amenity required by finding (b) of this Section, and a certification for design changes pursuant to Section 37-625 shall not be required. Where a publicly accessible open area was improved and is fully compliant with a prior certification pursuant to Section 37-625 that was granted before January 19, 2016, the further improvement of such publicly accessible open area shall not be required.
The provision of a compensating amenity as part of a prior certification pursuant to Section 91-83 (Retail Uses Within Existing Arcades) or a prior authorization pursuant to this Section may satisfy the requirement of finding (b) of this Section for a compensating amenity.
As part of the authorization, a horizontal enlargement of the ground floor level may be permitted within the area between a street wall and an arcade that did not generate a floor area bonus prior to June 21, 2016. The provisions of Section 91-831 (Ground floor requirements) shall not apply to such portion of the horizontal enlargement.
As part of the authorization, a horizontal enlargement of the ground floor level may be permitted along existing building walls that do not face an arcade. The locational requirements of paragraph (a)(1) of Section 91-831 and the frontage prohibitions of paragraph (b)(1)(ii) of Section 91-831 shall apply to such enlargement. Where the enlargement is located adjacent to a publicly accessible open area, the use and transparency requirements of Section 91-831 for new building walls facing a publicly accessible open area shall apply.
For a horizontal enlargement of 7,500 square feet or greater, a special permit pursuant to Section 91-85 shall also be required. For the purposes of calculating the total area of the horizontal enlargement that is subject to the special permit, the aggregate area of the horizontal enlargement permitted by prior certifications pursuant to Sections 91-83 and 91-837 (Subsequent design changes) and prior authorizations pursuant to this Section shall be included in such calculation, except the area of an indoor public space shall be excluded from such calculation.
Where any portion of the arcade remains open and accessible, such remaining arcade area shall maintain a minimum level of illumination of not less than five horizontal foot candles between sunset and sunrise. Any non-transparent portion of a building wall between columns that fronts on such arcade area shall be treated with artwork, planting or decorative material. Additional requirements for transparency in paragraph (c)(3) of Section 91-831 may apply.
All plans for arcades, publicly accessible open areas, required open areas and indoor public spaces, once authorized, shall be filed and duly recorded in the Borough Office of the City Register of the City of New York, indexed against the property in the form of a legal instrument, in a form satisfactory to the Commission, providing notice of the authorization pursuant to this Section. The filing and recording of such instrument shall be a precondition to the issuance of a building permit. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date. Where a compensating amenity required by paragraph (b) of this Section is located on the same zoning lot as an enlargement, no temporary or final certificate of occupancy shall be issued for any enlargement unless and until the compensating amenity has been substantially completed in accordance with the approved plans, as verified by the Department of City Planning to the Department of Buildings.
Where a compensating amenity is located within a street or public park pursuant to Section 91-835 (Alternative improvements), the applicable legal requirements of Section 91-836 (Additional requirements) shall apply.
Where a zoning lot is subject to a variance or special permit that was granted by the Board of Standards and Appeals, the requirements of paragraph (b) Section 91-836 shall apply.
The Commission may prescribe appropriate conditions and safeguards in connection with the grant of such authorization.
The City Planning Commission may authorize a modification of the requirements of Section 91-831 (Ground floor requirements), the provisions of Sections 91-832 (Plaza improvements) and 91-833 (Special regulations for plazas less than 40 feet in depth) for publicly accessible open areas and the provisions of Section 91-834 for indoor public spaces. In no event shall an enlargement be permitted within a publicly accessible open area or other required open area unless specified on Map 9 of Appendix A of this Chapter.
In order to grant such authorization, the Commission shall find:
- the location, use, access, size and treatment of the enlargement would result in a superior urban design relationship with the surrounding streets, buildings and open areas;
- the usefulness and attractiveness of the publicly accessible open area, required open area or indoor public space will be assured by the proposed layout and design, and that such modification will result in a superior urban design relationship with surrounding streets, buildings and public open areas; and
- any waiver of required amenities and circulation paths is the minimum necessary to create a better site plan.
The Commission may prescribe appropriate conditions and controls to enhance the relationship between the enlargement, publicly accessible open area, required open area or indoor public space and the surrounding streets, buildings and open areas.
The City Planning Commission may authorize an alternative improvement not listed in Section 91-835 provided that the Commission finds that the new amenity will better serve the purpose of the Water Street Subdistrict described in Section 91-00 (GENERAL PURPOSES).
As a condition of the authorization, for a compensating amenity that is located within a street or public park, the commitment to provide or maintain such compensating amenity shall be duly recorded in the form of a signed declaration of restrictions, including a maintenance agreement with the Department of Parks and Recreation or other relevant agency, indexed against the zoning lot, binding the owners, successors and assigns. Such declaration or maintenance agreement may require security in the form of a bond or letter of credit to ensure that the compensating amenity is maintained in accordance with the declaration or maintenance agreement. The form and content of the legal instrument shall be satisfactory to the Commission, and the filing of such instrument in the New York County Office of the City Register shall be a precondition to the issuance of a building permit. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
The Commission may prescribe appropriate conditions and safeguards in connection with the grant of such authorization.
In addition to any certification pursuant to Section 91-83 (Retail Uses Within Existing Arcades), inclusive, or an authorization pursuant to Section 91-841 (Authorization for retail uses within existing arcades), the City Planning Commission may permit a horizontal enlargement of 7,500 square feet or greater within Areas A or B on Map 9 in Appendix A of this Chapter, provided that the Commission finds that the public amenity or improvement that is provided on the zoning lot is of equal or greater benefit to the public than the arcade to be eliminated or reduced.
For the purposes of calculating the total area of the horizontal enlargement that is subject to the special permit, the aggregate area of the horizontal enlargement permitted by any prior certification pursuant to Section 91-83, inclusive, and prior authorizations pursuant to Section 91-841 shall be included in such calculation, except the area of an indoor public space provided in accordance with the provision of Section 91-834 (Indoor public spaces) shall be excluded from such calculation.
As part of the special permit, the Commission may modify the requirements of Section 91-831 (Ground floor requirements), the provisions of Sections 91-832 (Plaza improvements) and 91-833 (Special regulations for plazas less than 40 feet in depth) for publicly accessible open areas and the provisions of Section 91-834 for indoor public spaces. In no event shall an enlargement be permitted within a publicly accessible open area or other required open area unless specified on Map 9 in Appendix A of this Chapter.
The Commission may prescribe additional conditions and safeguards to enhance the relationship between the enlargement and the surrounding streets, buildings and public open areas.
The "Special Park Improvement District" established in this Resolution is designed to promote and protect public health, safety, general welfare and amenity. These general goals include, among others, the following specific purposes:
- to preserve and protect the unique character and architectural quality of the residential part of Fifth Avenue and Park Avenue which includes many landmarks and other cultural buildings;
- to provide alternatives to plaza and arcade development along Fifth Avenue and Park Avenue which are redundant in view of the existence of Central Park and the Park Avenue malls;
- to channel private expenditures which would otherwise be spent on redundant facilities into development, beautification and maintenance of proximate public parks and other public areas;
- to encourage the development of buildings compatible with the height of present development; and
- to promote the most desirable use of land in this area and thus to conserve the value of land and buildings and thereby protect the City's tax revenues.
Development
For purposes of this Chapter a "development" includes the construction of a new building or other structure on a zoning lot, the relocation of an existing building on another zoning lot, and an enlargement involving an increase in lot coverage.
Except as modified by the express provisions of this Chapter, the regulations of the underlying district remain in effect.
For the purposes of this Chapter, Duke Ellington Circle, located at the intersection of Fifth Avenue and East 110th Street, shall be considered a separate street.
For transit-adjacent sites or qualifying transit improvement sites, in the event of a conflict between the provisions of this Chapter and the provisions of Article VI, Chapter 6 (Special Regulations Applying Around Mass Transit Stations), the provisions of Article VI, Chapter 6 shall control. For the purposes of this paragraph, defined terms additionally include those in Section 66-11 (Definitions).
In flood zones, in the event of a conflict between the provisions of this Chapter and the provisions of Article VI, Chapter 4 (Special Regulations Applying in Flood Zones), the provisions of Article VI, Chapter 4 shall control.
For any zoning lot located between Fifth Avenue, Duke Ellington Circle, East 109th Street and East 110th Streets:
- commercial uses shall only be permitted beyond 100 feet of Fifth Avenue and shall be restricted to office uses listed in Use Group 6B;
- the underlying district sign regulations shall not apply. In lieu thereof, signs accessory to a commercial use shall conform with all the sign regulations applicable in C1 Districts, except that illuminated signs shall not be permitted and, within 100 feet of Fifth Avenue, signs shall conform with the sign regulations for Residence Districts set forth in Section 22-30.
The maximum floor area ratio for any zoning lot shall not exceed 10.0. No floor area bonuses shall be permitted. However, for developments or enlargements on qualifying transit improvement sites, a floor area bonus for mass transit station improvements may be granted by the City Planning Commission pursuant to the provisions of Section 66-51 (Additional Floor Area for Mass Transit Station Improvements). For the purposes of this paragraph, defined terms additionally include those in Section 66-11 (Definitions).
- Except as provided in paragraph (b) of this Section, the front building wall for all developments on zoning lots having frontage on Fifth Avenue or Park Avenue and for all developments along street lines within 50 feet of their intersection with the street lines of Fifth Avenue or Park Avenue, shall extend along the full length of its street line fronting on such street without setback for a height of 125 feet above curb level or the full height of the building, whichever is less. Above the height of 150 feet above curb level, the front building wall shall be set back 10 feet from the street line. The mandatory front building wall requirements are optional for the next 20 feet along the street line of a narrow street or for the next 75 feet along the street line of a wide street. However, where the front wall of a building with a height less than 125 feet above curb level was constructed with a setback from the street lines, enlargement of such building may be permitted by vertical extension of its existing building wall.
- For any zoning lot having frontage on Fifth Avenue, Duke Ellington Circle, East 109th Street and East 110th Street, the provisions of this paragraph (b) shall apply. The front building wall of any development shall extend along the full length of the Fifth Avenue and Duke Ellington Circle street lines, and along the full length of the East 109th Street and East 110th Street street lines within 50 feet of their intersection with Fifth Avenue and Duke Ellington Circle, and rise without setback to a minimum height of 85 feet above curb level or the full height of the building, whichever is less. Above a height of 150 feet, the front building wall shall be set back at least 10 feet from such street lines. Such mandatory front building wall requirements are optional for the next 50 feet along the East 109th Street and East 110th Street street lines.
- Front wall recesses are permitted within mandatory front building walls for architectural or decorative purposes, provided that the aggregate length at the level of any story does not exceed 50 percent of the length of the front wall where such recesses are permitted. The depth of such recesses shall not exceed six feet. No front wall recesses are permitted within 20 feet of the intersection of two street lines.
Where the aggregate width of balconies located along the front building wall, at the level of any story, exceeds 20 percent of the length of such front building wall, the front building wall may be set back not more than three feet from the street line.
The underlying district height and setback regulations apply along street lines, or portions thereof, not subject to the front building wall requirement.
The maximum height of a building or other structure, or portion thereof, shall not exceed 19 stories or 210 feet above curb level, whichever is less.
Within the portion of the Special Park Improvement District located within the Manhattan Core, the provisions of Article I, Chapter 3 (Comprehensive Off-street Parking and Loading Regulations in the Manhattan Core), inclusive, shall apply. For all other portions of the Special Park Improvement District, the provisions of this Section shall apply.
In no case shall the number of accessory off-street parking spaces for a residential use exceed 40 percent of the number of dwelling units. In no case shall curb cuts for vehicular access be located on Fifth Avenue or Park Avenue or on a street within 50 feet of its intersection with the street line of Fifth Avenue or Park Avenue. No off-site accessory off-street parking facilities for any use shall be permitted within the Special District. All parking spaces accessory to residences shall be designed and operated exclusively for the long term storage of the private passenger motor vehicles used by the occupants of such residences.
The "Special Hudson Yards District" established in this Resolution is designed to promote and protect public health, safety and general welfare. These general goals include, among others, the following specific purposes:
- to facilitate and guide the development of an environmentally beneficial, transit-oriented business and residence district by coordinating high density development with expanded mass transit facilities, extended and improved subway lines, improved pedestrian access to mass transit facilities, improved pedestrian circulation and avoidance of conflicts with vehicular traffic;
- to control the impact of buildings on the access of light and air to the streets and avenues of the Hudson Yards area and the surrounding neighborhoods;
- to provide an open space network comprised of public parks, public open space and public access areas through the establishment of a large-scale plan and other controls and incentives;
- to preserve the pedestrian orientation of ground floor uses, and thus safeguard a traditional quality of the City;
- to preserve the low- and medium-scale residential character of the Hell's Kitchen area;
- to provide a transition between the Hudson Yards District and the Clinton community to the north;
- to provide a transition between the Hudson Yards District and the Garment Center to the east;
- to provide a transition between the Hudson Yards District and the West Chelsea area to the south;
- to promote the use of the Jacob K. Javits Convention Center to the west by creating an active and attractive business district that facilitates pedestrian access to the Center;
- to provide flexibility of architectural design within limits established to assure adequate access of light and air to the street, and thus to encourage more attractive and economic building forms;
- to provide a transition between the Hudson Yards District and the Hudson River to the west;
- to facilitate the restoration and reuse of the High Line elevated rail line as an accessible, public open space through special height and setback regulations;
- to promote the most desirable use of land and building development in accordance with the District Plan for the Hudson Yards and thus conserve the value of land and buildings and thereby protect the City's tax revenues; and
- to limit the amount of off-street parking based on regulations that address the anticipated needs of residents, workers and visitors to the Hudson Yards Area, consistent with the objective of creating an area with a transit- and pedestrian-oriented neighborhood character.
ERY Culture, Festival and Exhibit Facility
An "ERY Culture, Festival and Exhibit Facility" is a use, operated by a not-for-profit entity, that comprises changing, non-permanent exhibits, events, expositions, presentations, festivals and fairs related to any or all of the following: visual arts, performing arts, culinary arts, literature, journalism, crafts, fashion and design, or any similar artistic activity. No trade shows shall be permitted unless they are related to one of such activities. Any building in which an ERY Culture, Festival and Exhibit Facility is located may include a moveable portion that may be extended and retracted to cover all or a portion of the Culture Facility Plaza described in Section 93-71, paragraph (j).
ERY High Line
For the purpose of this Chapter, the ERY High Line shall refer to the portion of the High Line between the western street line of Tenth Avenue and the western street line of Eleventh Avenue north of West 30th Street.
High Line
For the purpose of this Chapter, the "High Line" shall refer to the elevated rail line structure located between Gansevoort Street and West 34th Street in the north-south direction, and between Washington Street and Twelfth Avenue in the east-west direction.
High Line bed
The "High Line bed" is the highest level of the horizontal surface (platform) of the elevated rail line structure of the High Line.
High Line Landscape Improvement Deposit
For the purpose of this Chapter, the "High Line Landscape Improvement Deposit" shall be in the amount of $18,214,507 for the ERY High Line and, if the Tenth Avenue Spur is provided as a public access area pursuant to Section 93-71, in the amount of $23,200,228, as adjusted by changes in the construction cost index published by the Engineering News-Record (ENR) for New York City, commencing as of January 2012. Payment of the High Line Landscape Improvement Deposit shall be in the form of cash or other form of immediately available funds. The High Line Landscape Improvement Deposit shall be held by the City, or an instrumentality of the City, as the Chairperson of the City Planning Commission shall designate, and shall be applied exclusively to the improvement for public use of the ERY High Line and, if applicable, the Tenth Avenue Spur.
High Line Maintenance Funding
For the purpose of this Chapter, High Line Maintenance Funding shall mean funding sufficient for the maintenance and ordinary repair of the ERY High Line and, if applicable, the Tenth Avenue Spur, in an amount acceptable to the City, as adjusted on an annual basis.
High Line Rehabilitation Deposit
For the purpose of this Chapter, the High Line Rehabilitation Deposit shall be in the amount of $9,580,763 for the ERY High Line and, if the Tenth Avenue Spur is provided as a public access area pursuant to Section 93-71, in the amount of $12,203,234, as adjusted by changes in the construction cost index published by the ENR for New York City commencing as of January, 2012. Payment of the High Line Rehabilitation Deposit shall be in the form of cash or other form of immediately available funds if plans and specifications for rehabilitation of the ERY High Line and, if applicable, the Tenth Avenue Spur, have been substantially completed as of the time the High Line Rehabilitation Deposit is required, and if such plans and specifications have not been substantially completed at the time the High Line Rehabilitation Deposit is required, in the form of cash or a cash equivalent, such as a letter of credit, in a form acceptable to the City. The High Line Rehabilitation Deposit shall be held by the City, or an instrumentality of the City, as the Chairperson of the City Planning Commission shall designate, and shall be applied exclusively to the rehabilitation of the ERY High Line and, if applicable, the Tenth Avenue Spur.
Hudson Yards District Improvement Fund
The "Hudson Yards District Improvement Fund" (the "Fund") shall be an account of the Hudson Yards Infrastructure Corporation (the "Corporation"). The Fund shall be owned for all purposes by the Corporation and may be used for any corporate purpose of the Corporation, including its pledge, assignment or sale in furtherance of any financing by the Corporation in support of district improvements in the Hudson Yards Redevelopment Area. The Corporation, as owner for all purposes of the Fund, will manage the Fund in furtherance of the purposes of the Corporation.
Hudson Yards Redevelopment Area
The "Hudson Yards Redevelopment Area" shall be the areas within the Special Hudson Yards District, Subdistrict A-2 of the Special Garment Center District, the 42nd Street Perimeter Area of the Special Clinton District, and the area bounded by the center line of Eleventh Avenue, the northern street line of West 43rd Street, the westerly prolongation of the northern street line of West 43rd Street to the U.S. Pierhead Line, the U.S. Pierhead Line, the westerly prolongation of the southern street line of West 29th Street to the U.S. Pierhead Line, and the southern street line of West 29th Street. However, the area bounded by the westerly side of Eleventh Avenue, the southerly side of West 43rd Street, the westerly side of Twelfth Avenue and the northerly side of West 33rd Street shall not be included in the Hudson Yards Redevelopment Area, except for any portion of such blocks containing a transit easement for subway-related use. Furthermore, the Hudson Yards Redevelopment Area shall not include any underground connections from a subway station to any use located on such excluded blocks or between any such uses.
Phase 2 Hudson Boulevard and Park
The "Phase 2 Hudson Boulevard and Park" is the area within the Special Hudson Yards District bounded on the north by the center line of West 39th Street, on the east by the eastern boundary of the park located between West 38th and West 39th Streets and the eastern street line of Hudson Boulevard East, on the south by the center line of West 36th Street, and on the west by the western street line of Hudson Boulevard West and the western boundary of the park located between West 38th and West 39th Streets, as shown on Map 1 (Special Hudson Yards District, Subdistricts and Subareas) in Appendix A of this Chapter.
Tenth Avenue Spur
For the purpose of this Chapter, the Tenth Avenue Spur shall refer to the portion of the High Line above the intersection of Tenth Avenue and West 30th Street.
The provisions of this Chapter shall apply within the Special Hudson Yards District. The regulations of all other chapters of this Resolution are applicable, except as superseded, supplemented or modified by the provisions of this Chapter. In the event of a conflict between the provisions of this Chapter and other regulations of this Resolution, the provisions of this Chapter shall control. However, in flood zones, or for transit-adjacent sites or qualifying transit improvement sites, as defined in Section 66-11 (Definitions), in the event of a conflict between the provisions of this Chapter and the provisions of Article VI, Chapter 4 (Special Regulations Applying in Flood Hazard Areas), or Article VI, Chapter 6 (Special Regulations Applying Around Mass Transit Stations), the provisions of Article VI shall control.
The regulations of this Chapter are designed to implement the Special Hudson Yards District Plan.
The District Plan includes the following six maps in Appendix A of this Chapter:
Map 1 Special Hudson Yards District, Subdistricts and Subareas
Map 2 Mandatory Ground Floor Retail
Map 3 Mandatory Street Wall Requirements
Map 4 Mandatory Sidewalk Widenings
Map 5 Transit Facilities
Map 6 Sites Where Special Parking Regulations Apply
Subdistrict Plans include the following five maps in Appendix B of this Chapter:
Map 1 Subdistrict B: 450 West 33rd Street and Ninth Avenue Rail Yard Public Access Area Plan
Map 2 Subdistrict F: Site Plan
Map 3 Subdistrict F: Public Access Area Plan
Map 4 Subdistrict F: Mandatory Ground Floor Requirements
Map 5 Subdistrict F: Mandatory Street Wall Requirements
The Maps are hereby incorporated and made part of this Resolution. They are incorporated for the purpose of specifying locations where special regulations and requirements set forth in the text of this Chapter apply.
In order to carry out the provisions of this Chapter, six subdistricts are established, as follows:
Large-Scale Plan Subdistrict A
Farley Corridor Subdistrict B
34th Street Corridor Subdistrict C
Hell's Kitchen Subdistrict D
South of Port Authority Subdistrict E
Western Rail Yard Subdistrict F
Eleventh Avenue Subdistrict G
In each of these subdistricts, certain special regulations apply which do not apply within the remainder of the Special Hudson Yards District. Within certain subdistricts, subareas are established, as follows:
Within the Large-Scale Plan Subdistrict A:
Eastern Rail Yard Subarea A1
Four Corners Subarea A2
Subarea A3
Subarea A4
Subarea A5
Within Farley Corridor Subdistrict B:
Western Blocks Subarea B1
Central Blocks Subarea B2
Farley Post Office Subarea B3
Pennsylvania Station Subarea B4
Within Hell's Kitchen Subdistrict D:
Subarea D1
Subarea D2
Subarea D3
Subarea D4
Subarea D5
Within these subareas, certain special regulations apply which do not apply within the remainder of the subdistrict.
The subdistricts and subareas are outlined on Map 1 (Special Hudson Yards District, Subdistricts and Subareas) in Appendix A of this Chapter. Additional requirements for specific subdistricts, or portions thereof, are outlined in Appendix B of this Chapter.
Within the Hudson Yards Redevelopment Area, Section 11-332 (Extension of period to complete construction) shall apply, except that notwithstanding the provisions of paragraph (a) of such Section, in the event that other construction for which a building permit has been lawfully issued and for which construction has been commenced but not completed on January 19, 2005, such other construction may be continued provided that the construction is completed and a temporary or permanent certificate of occupancy is obtained not later than January 19, 2006.
Public parking lots authorized prior to January 19, 2005, and accessory off-street parking facilities for which a special permit has been granted prior to January 19, 2005, may be renewed subject to the terms of such authorization or special permit.
The provisions of Article I, Chapter 3, in their entirety shall be applied to Subdistricts F and G.
The following provisions of Article I, Chapter 3, governing automated parking facilities, as defined in Section 13-02, automobile rental establishments, commercial vehicle parking, and off-street loading berths shall apply to Subdistricts A, B, C, D and E, as applicable:
- for automated parking facilities, the provisions of Section 13-101 (Calculating parking spaces in automated parking facilities), paragraph (b) of Section 13-25 (Reservoir Spaces), and paragraph (b) of Section 13-27 (Minimum and Maximum Size of Parking Facilities);
- for automobile rental establishments, the provisions of Section 13-15 (Permitted Parking for Automobile Rental Establishments), paragraph (b) of Section 13-221 (Enclosure and screening requirements), Section 13-241 (Location of curb cuts), paragraph (b) of Section 13-242 (Maximum width of curb cuts), paragraph (c) of Section 13-25, and paragraph (c) of Section 13-27;
- for commercial vehicle parking, the provisions of Section 13-16 (Permitted Parking for Car Sharing Vehicles and Commercial Vehicles); and
- for off-street loading berths, the provisions of Section 13-30, inclusive.
Additional provisions of Article I, Chapter 3, shall be applicable as specified in Section 93-80, inclusive.
The following special permits by the Board of Standards and Appeals shall not be applicable:
Section 73-16 (Public Transit, Railroad or Electric Utility Substations) shall not apply to electrical utility substations. In lieu thereof, such uses shall be allowed within the Special Hudson Yards District upon authorization of the City Planning Commission pursuant to Section 93-18 (Authorization for Electrical Utility Substations)
Section 73-62 (Modification of Bulk Regulations for Buildings Containing Residences)
Section 73-63 (Enlargement of Non-residential Buildings)
Section 73-64 (Modifications for Community Facility Uses).
- The following special permits by the City Planning Commission shall not be applicable:Section 74-61 (Public Transit, Railroad or Electric Utility Substations) shall not apply to electrical utility substations. In lieu thereof, such uses shall be allowed within the Special Hudson Yards District upon authorization of the City Planning Commission pursuant to Section 93-18 (Authorization for Electrical Utility SubstationsSection 74-68 (Development Within or Over a Right-of-way or Yards)Section 74-72 (Bulk Modification)Section 74-74 (Large-scale General Development) shall be inapplicable in the Large-scale Plan Subdistrict ASection 74-83 (Court Houses)Section 74-841 (Development in certain Commercial Districts)Section 74-852 (Height and setback regulations for zoning lots divided by district boundaries)Section 74-87 (Covered Pedestrian Space)Section 74-91 (Modification of Public Plazas)Section 74-95 (Modifications of Housing Quality Special Permits).
- The following provisions regarding special permits by the City Planning Commission shall be applicable as modified:
Section 74-52 (Parking Garages or Public Parking Lots in High Density Central Areas) shall be applicable to the renewal of City Planning Commission special permits for public parking lots and public parking garages granted prior to April 14, 2010.
Section 74-79 (Transfer of Development Rights From Landmark Sites) shall apply, except that within the Pennsylvania Station Subarea B4 of the Farley Corridor Subdistrict B, such section shall be applicable only for a development or enlargement that has increased its permitted floor area ratio to 15.0 pursuant to Section 93-35 (Special Permit for Transit Bonus in Pennsylvania Station Subarea B4). Furthermore, the maximum amount of floor area that may be transferred from the zoning lot occupied by a landmark building may increase the maximum allowable floor area ratio within the Pennsylvania Station Subarea B4 to 19.5.
Section 74-82 (Through Block Arcades) shall apply to any development or enlargement for which a through block arcade would not otherwise be permitted pursuant to this Chapter, except that no floor area bonus shall be permitted.
Where the lot line of a zoning lot coincides with the boundary of the public parks located between West 35th Street, Hudson Boulevard East, West 33rd Street and Eleventh Avenue, such lot line shall be considered to be the street line of Hudson Boulevard West for the purposes of applying all use and bulk regulations of this Resolution.
Where the lot line of a zoning lot coincides with the boundary of the public park located between West 39th Street, Tenth Avenue, West 38th Street and Eleventh Avenue, such lot line shall be considered to be the street line of Hudson Boulevard East and West, as applicable, for the purposes of applying all use and bulk regulations of this Resolution.
No building permit shall be issued for any development or enlargement within Subdistrict F unless a declaration of restrictions, in substantially the form reviewed by the City Planning Commission pursuant to CEQR No. 09DCP007M and referenced in and made an exhibit to the findings of the Commission pursuant to 6 NYCRR Section 617.11 in connection with its adoption of the regulations of this Chapter and as modified by the City Council, applicable to Subdistrict F (as such declaration may be revised prior to filing and recordation in accordance with the provisions thereof applicable to amendments made subsequent to filing and recordation), shall have been filed and duly recorded in the Borough Office of the City Register of the City of New York and indexed against all property interests in Subdistrict F proposed for development or enlargement pursuant to this Chapter.
The use regulations of the underlying districts are modified as set forth in this Section, inclusive.
The only permitted change of use for the High Line shall be to provide publicly accessible open space in accordance with the provisions of Sections 93-71 (Public Access Areas in the Eastern Rail Yard Subarea A1) and 93-75 (Publicly Accessible Open Spaces in Subdistrict F).
For purposes of this Chapter, all references to community facility, community facility use or uses in Use Groups 3 or 4 in connection with Eastern Rail Yard Subarea A1 shall be deemed to include an ERY Culture, Festival and Exhibit Facility.
No residential use shall be permitted within the Pennsylvania Station Subarea B4 of the Farley Corridor Subdistrict B.
Within the Large-Scale Plan Subdistrict A, Subareas B1 and B2 of the Farley Corridor Subdistrict B, and the South of Port Authority Subdistrict E, residential use shall be permitted only upon certification of the Chairperson of the City Planning Commission that the zoning lot on which such residential use is located contains the minimum amount of commercial floor area required before residential use is allowed, as specified in Section 93-21 (Floor Area Regulations in the Large-Scale Plan Subdistrict A) or 93-22 (Floor Area Regulations in Subdistricts B, C, D, E and F), as applicable, and that for zoning lots in Subareas A2 through A5 of the Large-Scale Plan Subdistrict A, a certification pursuant to Section 93-34 (Distribution of Floor Area in the Large-Scale Plan Subdistrict A) has been made.
However, special regulations shall apply to zoning lots with phased development, as follows:
- except as provided in paragraph (c) of this Section, for zoning lots with less than 69,000 square feet of lot area, the Chairperson shall allow for phased development, upon certification that a plan has been submitted whereby the ratio of commercial floor area to residential floor area, in buildings in each phase, is no smaller than the ratio of the minimum amount of commercial floor area required on the zoning lot before residential use is allowed, to the maximum residential floor area permitted on the zoning lot as specified in Section 93-21 or 93-22, as applicable;
- for zoning lots with at least 69,000 square feet of lot area, the Chairperson shall allow for one or more buildings containing residences to be developed or enlarged without the minimum amount of commercial floor area required before residential use is allowed, as specified in Section 93-21 or 93-22, as applicable, upon certification that a plan has been submitted whereby one or more regularly shaped portions of the zoning lot with a minimum area of 50,000 square feet are reserved for future development of not more than two million square feet of commercial floor area on each such portion, and that, upon full development of such zoning lot, the ratio of commercial floor area to residential floor area shall be no smaller than the ratio of the minimum amount of commercial floor area required on the zoning lot before residential use is allowed, to the maximum residential floor area permitted on the zoning lot, as specified in Section 93-21 or 93-22, as applicable; and
- for zoning lots with at least 55,000 square feet but less than 69,000 square feet of lot area within Subarea A3 of the Large-Scale Plan Subdistrict A, the Chairperson shall allow for one or more buildings containing residences to be developed or enlarged without the minimum amount of commercial floor area required before residential use is allowed, as specified in paragraph (a) of Section 93-21, upon certification that a plan has been submitted whereby one or more regularly shaped portions of the zoning lot with a minimum area of 35,000 square feet are reserved for future development, and that, upon full development of such zoning lot, the ratio of commercial floor area to residential floor area shall be no smaller than the ratio of the minimum amount of commercial floor area required on the zoning lot before residential use is allowed, to the maximum residential floor area permitted on the zoning lot, as specified in Section 93-21.
All developments or enlargements so certified shall be permitted only in accordance with the provisions of this Chapter.
The provisions of Section 32-422 (Location of floors occupied by commercial uses) are modified to permit residential uses on the same story as a commercial use provided no access exists between such uses at any level containing dwelling units and provided any commercial uses are not located directly over any story occupied in whole or in part by dwelling units. However, such commercial uses may be located over such a story occupied by dwelling units by authorization of the City Planning Commission upon a finding that sufficient separation of residential uses from commercial uses exists within the building.
In Commercial Districts mapped within R8A Districts, a residential use existing on December 21, 2005, within a story that has a floor level within five feet of curb level, may not be converted to a commercial use.
The provisions of this Section shall apply to all developments or enlargements in the Hudson Yards Redevelopment Area, with the exception of Subdistricts F and G.
- No temporary certificate of occupancy from the Department of Buildings may be issued for any portion of a development or enlargement in the Hudson Yards Redevelopment Area that includes Use Group 6B offices developed or enlarged after January 19, 2005, until the Chairperson of the Department of City Planning certifies to the Commissioner of Buildings that:
- such development or enlargement does not utilize any floor area increases pursuant to Sections 23-154 (Inclusionary Housing) or 96-25 (Floor Area Bonus for New Theater Use); or
- such development or enlargement utilizes floor area increases pursuant to Sections 23-154, 93-30 (SPECIAL FLOOR AREA REGULATIONS), inclusive, or 96-25, and will not result in a total amount of Use Group 6B office floor area developed or enlarged after January 19, 2005, within the Hudson Yards Redevelopment Area of over 20 million square feet.All developments or enlargements so certified shall be permitted in accordance with the provisions of this Chapter, or the provisions of the Special Clinton District or the Special Garment Center District, as applicable.
- Where the Chairperson of the Department of City Planning determines that the amount of office floor area in any development or enlargement will result in a total amount of Use Group 6B office floor area developed or enlarged after January 19, 2005, within the Hudson Yards Redevelopment Area of over 20 million square feet, no building permit from the Department of Buildings shall be issued for any development or enlargement that includes Use Group 6B offices constructed after January 19, 2005, until the Chairperson certifies to the Commissioner of Buildings that:
- such development or enlargement does not utilize any floor area increases pursuant to Sections 23-154, 93-30, inclusive, or 96-25; or
- such development or enlargement utilizes floor area increases pursuant to Sections 23-154, 93-30, inclusive, or 96-25, and will not result in a total amount of Use Group 6B office floor area developed or enlarged after January 19, 2005, within the Hudson Yards Redevelopment Area of over 25 million square feet.All developments or enlargements so certified shall be permitted in accordance with the provisions of this Chapter, or the provisions of the Special Clinton District or the Special Garment Center District, as applicable.
However, if such developments or enlargements fail to comply with the provisions of Section 11-331 with respect to completion of foundations within one year of the date of certification pursuant to this Section, such building permit shall lapse, and any new building permit will require a new Chairperson's certification pursuant to this Section.
- Where the Chairperson of the Department of City Planning determines that the amount of office floor area in any development or enlargement will result in a total amount of Use Group 6B office floor area developed or enlarged after January 19, 2005, within the Hudson Yards Redevelopment Area of over 25 million square feet, and where such development or enlargement utilizes floor area increases pursuant to Sections 23-154, 93-30, inclusive, or 96-25, such development or enlargement shall be permitted only upon authorization of the City Planning Commission pursuant to Section 93-132.
However, no such authorization shall be required for developments or enlargements utilizing the Inclusionary Housing Program within the area bounded by West 35th Street, Eighth Avenue, West 33rd Street, and a line 100 feet east of and parallel to Ninth Avenue, or in the 42nd Street Perimeter Area of the Special Clinton District, where the total floor area ratio for such developments or enlargements does not exceed 12.0.
The provisions of this Section shall apply to all developments or enlargements in the Hudson Yards Redevelopment Area, with the exception of Subdistricts F and G.
Where the amount of Use Group 6B office floor area in a development or enlargement will result in over 25 million square feet of such use developed or enlarged after January 19, 2005, within the Hudson Yards Redevelopment Area, and such development or enlargement utilizes increased floor area pursuant to Sections 23-154 (Inclusionary Housing), 93-30 (SPECIAL FLOOR AREA REGULATIONS), inclusive, or 96-25 (Floor Area Bonus for New Theater Use), such development or enlargement shall be permitted only upon authorization of the City Planning Commission that:
- such development or enlargement will not require any significant additions to the supporting services of the neighborhood or that provisions for adequate supporting services have been made;
- the streets providing access to the development or enlargement are adequate to handle the traffic generated thereby or provisions have been made to handle such traffic; and
- such development or enlargement is consistent with the goals of the applicable special district.
Within Subdistrict G, Use Group 16C commercial or public utility vehicle storage, open or enclosed, including accessory motor fuel pumps shall be permitted as-of-right. The floor area of a building shall not include floor space used for public utility vehicle storage provided in any story located not more than 56 feet above curb level.
The following provisions relating to retail continuity and transparency requirements shall apply to all subdistricts in the Special Hudson Yards District, except that the provisions of this Section shall not apply in Subdistrict G and along the northern street frontage of West 35th through West 39th Streets within 100 feet of Eleventh Avenue, as shown on Map 2 (Mandatory Ground Floor Retail) in Appendix A of this Chapter. However, any zoning lot fronting on such streets and partially within 100 feet of Eleventh Avenue may, as an alternative, apply the provisions of this Section to the entire West 35th, West 36th, West 37th, West 38th or West 39th Street frontage of the zoning lot.
- Retail continuity along designated streets in Subdistricts A, B, C, D and E
Map 2 in Appendix A of this Chapter specifies locations where the special ground floor use and transparency requirements of this Section apply. Such regulations shall apply along either 100 percent or 50 percent of the building's street frontage, as indicated on Map 2.
Uses within stories that have a floor level within five feet of curb level shall be limited to commercial uses permitted by the underlying district, not including uses listed in Use Groups 6B, 6E, 7C, 7D, 8C, 8D, 9B, 10B, 11 or 12D. Such uses shall comply with the minimum depth provisions of Section 37-32 (Ground Floor Depth Requirements for Certain Uses).
A building's street frontage shall be allocated exclusively to such uses, except for lobby space, entryways, entrances to subway stations, other subway-related uses as described in Section 93-65 (Transit Facilities), or within the Eastern Rail Yard Subarea A1 where such retail continuity requirements are applicable to building walls facing certain public access areas, pursuant to Section 93-71, as follows:- for building walls facing the outdoor plaza described in Section 93-71, paragraph (b): the through block connection described in Section 93-71, paragraph (d), and the connection to the public plaza described in Section 93-71, paragraph (e);
- for building walls facing the through block connection described in Section 93-71, paragraph (d): the outdoor plaza described in Section 93-71, paragraph (b);
- for building walls facing the connection to the public plaza described in Section 93-71, paragraph (e): the outdoor plaza described in Section 93-71, paragraph (b) and the public plaza described in Section 93-71, paragraph (c); or
- a combination of retail uses and public access areas so as to satisfy such depth requirement for retail continuity.The length of street frontage (exclusive of any portion of such street frontage allocated to entrances to subway stations and other subway-related uses) occupied by lobby space or entryways shall comply with the applicable provisions for Type 2 lobbies in Section 37-33 (Maximum Width of Certain Uses), except within the Eastern Rail Yard Subarea A1, where the width of a lobby located on a building wall facing the eastern boundary of the outdoor plaza may occupy 120 feet or 25 percent of such building wall, whichever is less, and within the Four Corners Subarea A2 of the Large-Scale Plan Subdistrict A, for a development occupying a full block with frontage on Hudson Boulevard East and Tenth Avenue and having two million or more square feet of floor area, the width of lobbies located on the Hudson Boulevard East street frontage or the Tenth Avenue street frontage may occupy up to 70 feet of the building wall width of the building located on each such frontage.
- Retail continuity along designated streets in Subdistrict F
Map 4 (Subdistrict F: Mandatory Ground Floor Requirements) in Appendix B specifies locations where the special ground floor use and transparency requirements of this Section apply. Such regulations shall apply along either 100 percent or 70 percent of the building's street frontage, as indicated for each location on Map 4.- Along Eleventh Avenue
The ground floor retail provisions established in paragraph (a) of this Section shall apply to the ground floor street frontage of buildings along Eleventh Avenue. In addition, if a street frontage is occupied by a bank, as listed in Use Group 6, such a street frontage shall not exceed a street wall width, in total, of 25 feet. - Along designated streets other than Eleventh Avenue
In addition to the uses listed in paragraph (a) of this Section, the following community facility uses from Use Groups 3 and 4 as well as the following commercial use from Use Group 6B shall be permitted within a story that has a floor level within five feet of curb level for frontages along designated streets, as shown on Map 4, other than Eleventh Avenue.
From Use Group 3:Art galleries, non-commercialLibrariesMuseumsNursery, kindergarten, elementary or secondary schools (with no living or sleeping accommodations)From Use Group 4:Ambulatory diagnostic and treatment health care facilitiesCommunity centersHouses of worshipRecreation centers, non-commercialFrom Use Group 6B:Veterinary medicine, limited to small animals.A minimum of 70 percent of the aggregate width of street wall shall be occupied by uses permitted in this Section. A minimum of 50 percent of the street frontage of a building shall be allocated exclusively to uses listed in paragraph (a) and Use Group 3 uses listed in this paragraph, (b)(2). In addition, a maximum of 20 percent of the street frontage of a building shall be permitted to provide the Use Group 4 and 6B uses listed in this paragraph, (b)(2). However, if a street frontage is occupied by a bank, as listed in Use Group 6, such street frontage shall not exceed a street wall width, in total, of 25 feet.
The remaining portion of the street wall may be occupied by uses listed in this Section, or by lobby space, mechanical space or entrances to accessory parking garages, provided that:- the maximum width of a single lobby frontage shall comply with the provisions for Type 2 lobbies set forth in Section 37-33. A maximum of two such lobbies shall be permitted along a single street wall frontage, provided that the minimum distance between such lobbies shall not be less than 120 feet; and
- the maximum width of a street wall occupied by an entrance to accessory parking spaces shall not exceed 35 feet.
- Along Eleventh Avenue
- Transparency requirements along designated streets in Subdistricts A, B, C, D, E and F
For any development or ground floor enlargement fronting on streets designated on Map 2 in Appendix A of this Chapter, glazing shall be provided in accordance with the provisions set forth in paragraph (c) of this Section.
Each ground floor level street wall of a commercial or community facility use, as set forth in this Section, shall be glazed in accordance with Section 37-34 (Minimum Transparency Requirements).
For developments or enlargements fronting upon Hudson Boulevard that are adjacent to existing buildings located within the Hudson Boulevard street bed or public park, the Hudson Boulevard street wall of such development or enlargement shall be designed in a manner that will enable the glazing requirements of this Section to be met upon demolition of the buildings within such street bed or public park and, within six months of such demolition, such glazing requirements shall be complied with. - Non-transparent walls within Subdistrict F
Within Subdistrict F, any non-transparent area of a new or existing wall with a width in excess of 40 feet and a height in excess of five feet fronting upon a public sidewalk or publicly accessible open space shall be treated with a decorative element or material or shall be screened with planting so as to provide visual relief. Such screening or decorative treatment shall be required to a height of 15 feet above the level of the public sidewalk or publicly accessible open space, or the height of the wall, whichever is less.
Within Subdistrict F, the Chairperson of the City Planning Commission may modify the ground floor level requirements of paragraphs (b), (c) and (d) of Section 93-14 (Ground Floor Level Requirements), provided that the Chairperson certifies to the Commissioner of Buildings that such a change is the minimum necessary to accommodate the ventilation requirements of the below-grade rail operations. Any application for such change shall include a mechanical plan that conveys the extent of the needs and required modifications, as well as a letter from the Metropolitan Transportation Authority describing the needs for such modifications.
In C2-5, C2-8 and C6 Districts, the provisions of Sections 32-17 (Use Group 8) and 32-21 (Use Group 12) with respect to public parking garages and public parking lots are inapplicable and are superseded by the provisions of Section 93-80 (OFF-STREET PARKING REGULATIONS).
- Subdistricts A, B, C, D and E
Within Subdistricts A, B, C, D and E, the underlying sign regulations shall apply, except that flashing signs shall not be allowed within 100 feet of Hudson Boulevard, its northerly prolongation to West 39th Street and its southerly prolongation to West 33rd Street. Within the Pennsylvania Station Subarea B4, the provisions of Section 93-161 (Special permit for signs within the Pennsylvania Station Subarea) shall apply. The following modifications to the underlying sign regulations shall apply in the Eastern Rail Yard Subarea A1:- Flashing signs shall not be allowed on any portion of a building fronting upon the outdoor plaza required pursuant to Section 93-71.
- For signs facing Tenth Avenue, or on a portion of a building within 100 feet of Tenth Avenue, in addition to signs permitted under the underlying sign regulations:
- up to four signs may exceed the maximum height limitations of the underlying sign regulations, provided that no such sign exceeds 95 feet in height; and
- up to five signs may be located without regard to the maximum surface area limitations of the underlying sign regulations, provided that:
- the aggregate surface area of such signs does not exceed 4,400 square feet; and
- each such sign shall have a maximum surface area of 650 square feet, except for one sign that may have a maximum surface area of 1,800 square feet.
Any sign which exceeds the maximum height permitted by the underlying sign regulations shall direct attention to no more than one business conducted on the zoning lot and no such signs shall be flashing signs. Additionally, no more than two of the additional signs permitted under this paragraph (a)(2), if located below the maximum height permitted by the underlying sign regulations, shall be flashing signs.
Erection of one or both of the additional flashing signs permitted under this paragraph (a)(2) shall be conditioned upon and subject to additional limitations upon flashing effects for all flashing signs located on a building wall facing Tenth Avenue or on a building wall within 100 feet of Tenth Avenue, as prescribed by the City Planning Commission pursuant to a restrictive declaration. Recordation of such restrictive declaration in the Office of the Register and compliance with the terms thereof with respect to any previously erected flashing signs permitted under the underlying sign regulations shall be a precondition to the issuance of permits by the Commissioner of Buildings for an additional flashing sign permitted under this paragraph.
- Along the ERY High Line, the sign regulations as set forth in Section 93-16, paragraph (b)(1), shall apply. In addition, no flashing signs above the level of the High Line bed shall be located within 150 feet of and facing the ERY High Line.
- For an ERY Culture, Festival and Exhibit Facility, the total surface area of all permitted signs and banners shall be as set forth in this paragraph, (a)(4). The maximum aggregate surface area of all signs shall not exceed 2,700 square feet. Signs, other than banners, facing the outdoor plaza, as described in Section 93-71, paragraph (b), shall not exceed a maximum aggregate surface area of 200 square feet; signs facing the connection to the High Line, as described in Section 93-71, paragraph (f), shall not exceed a maximum aggregate surface area of 200 square feet; and signs facing West 30th Street shall not exceed a maximum aggregate surface area of 1,700 square feet. A maximum of 600 square feet of signs in the form of banners are permitted facing or within the outdoor plaza. No sign shall exceed a height of 30 feet above the level of the Culture Facility Plaza, as described in Section 93-71, paragraph (j) and no signs facing West 30th Street shall be located at a height above the High Line. Banners located within the outdoor plaza may be installed on one or two poles located not less than 13 feet from an ERY Culture, Festival and Exhibit Facility. The bottom of any such banner shall be located at least 10 feet above the bottom of the pole. Any sign that exceeds 300 square feet of surface area shall be non-illuminated or a sign with indirect illumination.
- Subdistrict F
For the purposes of calculating the permitted surface area of a sign, each site set forth on Map 2 (Subdistrict F: Site Plan) in Appendix B shall be considered a separate zoning lot.- Along the High Line
The sign regulations of the underlying districts shall not apply to signs located within 50 feet of the High Line, except for signs located entirely below the level of the High Line bed. In lieu thereof, the sign regulations of a C1 District shall apply, except that accessory signs located within the High Line frontage may have a maximum height of 20 feet above the level of the High Line bed.
No signs affixed to or resting upon the High Line shall be permitted, except as pursuant to a signage plan for the High Line, as authorized by the City Planning Commission, provided the Commission finds that such signage plan will:- enhance the use of the High Line by providing signage that is consistent with the use of the High Line as a public open space;
- provide, at a minimum, directional, informational and interpretive signage consistent with the use of the High Line as a public open space;
- be integrated with the design of the High Line open space; and
- not adversely affect development adjacent to the High Line and in the surrounding neighborhood.
- Other locations
Within Subdistrict F, the underlying sign regulations shall apply for signs located beyond 50 feet of the High Line, and for portions of signs located entirely below the level of the High Line bed along West 30th Street. However, flashing signs shall not be permitted in Subdistrict F, except along frontages within 200 feet of the intersection of the West 33rd Street and Eleventh Avenue street lines.
For an arena permitted pursuant to Section 74-41 within Pennsylvania Station Subarea B4, the City Planning Commission may, by special permit, modify the applicable provisions of Sections 32-63 (Permitted Advertising Signs) to allow advertising signs, 32-64 (Surface Area and Illumination Provisions) to allow increased surface area along specified streets and 32-65 (Permitted Projection or Height of Signs), provided such signs comply with the conditions of paragraph (a) and the findings of paragraph (b) of this Section, as follows:
- Conditions
- no sign shall extend to a height greater than 85 feet above curb level ;
- all signs located below a height of 12 feet above curb level shall be limited in location and aggregate surface area to 550 square feet on the West 31st Street frontage of Subarea B4, 250 square feet on the West 33rd Street frontage of Subarea B4 and 850 square feet on the Eighth Avenue frontage of Subarea B4; and
- all signs located above a height of 12 feet above curb level shall be limited in location and aggregate surface area to 5,500 square feet within the through lot fronting on Eighth Avenue, 3,000 square feet within each corner lot fronting on Eighth Avenue, 3,000 square feet within the through lot portion of the West 31st Street frontage of Subarea B4 and 3,000 square feet within the through lot portion of the West 33rd Street frontage of Subarea B4.
- The Commission shall find that the location and placement of such signs is appropriate in the relationship to buildings and uses on the zoning lot and to adjacent open areas, and would be compatible with the character of the arena site, including its use as an entryway to Pennsylvania Station, and of the surrounding area.
For purposes of calculating the height of any sign permitted pursuant to this Section, curb level shall be defined as 30.755 feet above Manhattan datum.
The Commission may prescribe additional conditions and safeguards to minimize adverse effects on the character of the surrounding area, including limitations on the number, size and location of arena signs permitted pursuant to the district regulations.
In the Large-Scale Plan Subdistrict A, for a period of not more than 10 years after January 19, 2005, existing automobile repair establishments listed in Use Group 16 of Section 32-25 that were conforming prior to January 19, 2005, may be enlarged, provided that the floor area ratio of any such establishment, including any enlargement pursuant to this Section, does not exceed 5.0.
Electrical utility substations shall be allowed in the Special Hudson Yards District in order to serve the needs of the Special District, and the regulations thereof shall be modified as necessary to accommodate the operational needs of the substation, upon authorization of the City Planning Commission which shall be issued upon finding, with respect to a proposed site, that:
- to the extent reasonably permitted by the operational needs of the substation, the architectural and landscaping treatment of such use will blend harmoniously with the abutting area; and
- if the site proposed for such use is Subareas D4 or D5 of the Hell's Kitchen Subdistrict D of the Special Hudson Yards District, that there are difficulties in locating such use in other Subdistricts of the Special Hudson Yards District.
The Commission may, consistent with cost-effective operations and capital planning, and the operational needs of the substation, prescribe appropriate conditions and safeguards on matters necessary to effectuate the provisions of paragraph (a) of this Section which are not regulated by other applicable codes, laws, rules or regulations. The applicant shall provide the Department of City Planning with a general description of such codes, laws, rules or regulations and a certification that the proposed substations shall comply therewith.
The floor area regulations of this Section, inclusive, shall apply to zoning lots.
In the Large-Scale Plan Subdistrict A, the floor area provisions of this Section shall apply.
(a) Subareas A2 through A5
In Subareas A2 through A5, the basic maximum permitted floor area ratio shall be as specified in Row A in the table in this Section. Such floor area ratio may be increased to the maximum amount specified in Row B in the table, pursuant to Section 93-31 (District Improvement Fund Bonus) or the transfer of floor area or increase in the amount of floor area from the Phase 2 Hudson Boulevard and Park pursuant to Sections 93-32 or 93-33. For zoning lots that have maximized their permitted floor area through such floor area bonus or transfer provisions, the permitted floor area may be further increased to the maximum amount specified in Row C in the table through the distribution of floor area from the Eastern Rail Yard Subarea A1, pursuant to Section 93-34. Residential use shall only be permitted on a zoning lot with a non-residential floor area ratio, as follows, or as provided for phased developments pursuant to Section 93-122 (Certification for residential use in Subdistricts A, B and E):
In Subareas A2 through A5, the basic maximum permitted floor area ratio shall be as specified in Row A in the table in this Section. Such floor area ratio may be increased to the maximum amount specified in Row B in the table, pursuant to Section 93-31 (District Improvement Fund Bonus) or the transfer of floor area or increase in the amount of floor area from the Phase 2 Hudson Boulevard and Park pursuant to Sections 93-32 or 93-33. For zoning lots that have maximized their permitted floor area through such floor area bonus or transfer provisions, the permitted floor area may be further increased to the maximum amount specified in Row C in the table through the distribution of floor area from the Eastern Rail Yard Subarea A1, pursuant to Section 93-34. Residential use shall only be permitted on a zoning lot with a non-residential floor area ratio, as follows, or as provided for phased developments pursuant to Section 93-122 (Certification for residential use in Subdistricts A, B and E):
(1) 18.0 or more in Subareas A2 and A3
(2) 15.6 or more in Subarea A4
(3) 14.0 or more in Subarea A5.
MAXIMUM PERMITTED FLOOR AREA RATIO WITHIN SUBAREAS A2 THROUGH A5
Subarea A2 | Subarea A3 | Subarea A4 | Subarea A5 | |
ROW A Basic maximum floor area ratio (FAR) | 10.0 total 10.0 C 2.0 CF | 10.0 total 10.0 C 2.0 CF | 10.0 total 10.0 C 2.0 CF | 10.0 total 10.0 C 2.0 CF |
ROW B Maximum FAR through bonus pursuant to Section 93-31 or transfer or increase pursuant to Sections 93-32 or 93-33 | 18.0 total 18.0 C 2.0 CF | 18.0 total 18.0 C 2.0 CF | 18.0 total 18.0 C 2.4 R 2.0 CF | 18.0 total 18.0 C 4.0 R 2.0 CF |
ROW C Maximum FAR through distribution pursuant to Section 93-34 | 33.0 total 33.0 C 6.0 R 2.0 CF | 24.0 total 24.0 C 6.0 R 2.0 CF | 21.6 total 21.6 C 6.0 R 2.0 CF | 20.0 total 20.0 C 6.0 R 2.0 CF |
C = Commercial FAR
CF = Community Facility FAR
R = Residential FAR
(b) Eastern Rail Yard Subarea A1
The Eastern Rail Yard Subarea A1 shall generate a maximum floor area ratio of 19.0. The maximum floor area ratio for commercial use shall be 19.0, the maximum floor area ratio for residential use shall be 3.0, and the maximum floor area ratio for community facility use shall be 2.0. In order to promote a superior site plan, the amount of floor area permitted in the subarea shall be limited, and unused floor area may be distributed as follows:
The Eastern Rail Yard Subarea A1 shall generate a maximum floor area ratio of 19.0. The maximum floor area ratio for commercial use shall be 19.0, the maximum floor area ratio for residential use shall be 3.0, and the maximum floor area ratio for community facility use shall be 2.0. In order to promote a superior site plan, the amount of floor area permitted in the subarea shall be limited, and unused floor area may be distributed as follows:
(1) The maximum floor area ratio for any zoning lot in the subarea shall be 11.0. The maximum floor area ratio for commercial use shall be 9.0, the maximum floor area ratio for community facility use shall be 2.0, and the maximum floor area ratio for residential use shall be 3.0. Residential use shall only be permitted on a zoning lot with a non-residential floor area ratio of 8.0 or more, or as provided for phased developments pursuant to Section 93-122 (Certification for residential use in Subdistricts A, B and E).
Any floor space occupied by an ERY Culture, Festival and Exhibit Facility, including any floor space accessory thereto, that is located below the elevation of the Culture Shed Plaza described in Section 93-71, paragraph (j), within the moveable portion that may be extended and retracted to cover and enclose all or any portion of the Culture Facility Plaza, or within a portion of a building that contains residential use and is not designed to house such moveable portion, shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for community facility uses and the total maximum floor area ratio of the zoning lot. In addition, in a building containing both residential use and an ERY Culture, Festival and Exhibit Facility, any floor space occupied by elevator shafts, structural systems or stairwells serving the residential use that is either located on any story occupied entirely by the ERY Culture, Festival and Exhibit Facility, except for such elevator shafts, structural systems, and stairwells, or is located on a story occupied in part by the ERY Culture, Festival and Exhibit Facility where such elevator shaft or stairwell is not accessible for residential use on such story except for emergency egress, shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for residential uses and the total maximum floor area ratio of the zoning lot.
For a building, or portion of a building, containing residential use that is located adjacent to the ERY High Line, any floor space used for storage, restrooms, maintenance facilities or other support space for the ERY High Line shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for residential or community facility uses and the total maximum floor area ratio of the zoning lot.
Any floor space occupied by an ERY Culture, Festival and Exhibit Facility, including any floor space accessory thereto, that is located below the elevation of the Culture Shed Plaza described in Section 93-71, paragraph (j), within the moveable portion that may be extended and retracted to cover and enclose all or any portion of the Culture Facility Plaza, or within a portion of a building that contains residential use and is not designed to house such moveable portion, shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for community facility uses and the total maximum floor area ratio of the zoning lot. In addition, in a building containing both residential use and an ERY Culture, Festival and Exhibit Facility, any floor space occupied by elevator shafts, structural systems or stairwells serving the residential use that is either located on any story occupied entirely by the ERY Culture, Festival and Exhibit Facility, except for such elevator shafts, structural systems, and stairwells, or is located on a story occupied in part by the ERY Culture, Festival and Exhibit Facility where such elevator shaft or stairwell is not accessible for residential use on such story except for emergency egress, shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for residential uses and the total maximum floor area ratio of the zoning lot.
For a building, or portion of a building, containing residential use that is located adjacent to the ERY High Line, any floor space used for storage, restrooms, maintenance facilities or other support space for the ERY High Line shall be exempt from the definition of floor area for the purposes of calculating the permitted floor area ratio for residential or community facility uses and the total maximum floor area ratio of the zoning lot.
(2) Unused floor area may be distributed to zoning lots in Subareas A2 through A5 pursuant to Section 93-34, provided the total amount of distributed floor area does not exceed an amount equal to the lot area of the Eastern Rail Yard Subarea A1 multiplied by 10.0. Furthermore, the total floor area distributed to Subarea A2 shall not exceed 3,238,000 square feet.
(c) Phase 2 Hudson Boulevard and Park
For zoning lots or portions of zoning lots in the Phase 2 Hudson Boulevard and Park, the provisions of Section 93-32 (Floor Area Regulations in the Phase 2 Hudson Boulevard and Park) and 93-33 (Special Regulations for Residual Portions of Zoning Lots Partially Within the Phase 2 Hudson Boulevard and Park) shall apply.
Notwithstanding the provisions of this Section, the basic maximum permitted floor area ratio may be increased on an "adjacent lot" pursuant to Section 74-79 (Transfer of Development Rights From Landmark Sites), provided that the maximum floor area transferred from the landmark lot does not exceed the basic maximum permitted floor area ratio less the total floor area of all buildings on the landmark lot.
For zoning lots or portions of zoning lots in the Phase 2 Hudson Boulevard and Park, the provisions of Section 93-32 (Floor Area Regulations in the Phase 2 Hudson Boulevard and Park) and 93-33 (Special Regulations for Residual Portions of Zoning Lots Partially Within the Phase 2 Hudson Boulevard and Park) shall apply.
Notwithstanding the provisions of this Section, the basic maximum permitted floor area ratio may be increased on an "adjacent lot" pursuant to Section 74-79 (Transfer of Development Rights From Landmark Sites), provided that the maximum floor area transferred from the landmark lot does not exceed the basic maximum permitted floor area ratio less the total floor area of all buildings on the landmark lot.
(a) Subdistricts B, C, D and E
In Subdistricts B, C, D and E, the basic maximum floor area ratio is determined by the subdistrict and, where applicable, subarea, as specified in the table in this Section. The basic maximum floor area ratios for non-residential buildings are set forth in Row A, and the basic maximum floor area ratios for buildings containing residences are set forth in Row B. Such basic maximum floor area ratios may be increased to the amount specified in Row C only pursuant to Section 93-31 (District Improvement Fund Bonus) or as otherwise specified in Sections 93-221 through 93-224.
For a zoning lot with more than one building, the basic maximum floor area ratios set forth in Row A shall apply, provided that any building that is developed or enlarged after January 19, 2005, is wholly non-residential. If a building containing residences is developed or enlarged on such a zoning lot after January 19, 2005, the basic maximum floor area ratios set forth in Row B shall apply.
Notwithstanding the provisions of this Section, the basic maximum permitted floor area ratio may be increased on an "adjacent lot" pursuant to Section 74-79 (Transfer of Development Rights From Landmark Sites), provided that the maximum floor area transferred from the landmark lot does not exceed the basic maximum permitted floor area ratio less the total floor area of all buildings on the landmark lot.
In Subdistricts B, C, D and E, the basic maximum floor area ratio is determined by the subdistrict and, where applicable, subarea, as specified in the table in this Section. The basic maximum floor area ratios for non-residential buildings are set forth in Row A, and the basic maximum floor area ratios for buildings containing residences are set forth in Row B. Such basic maximum floor area ratios may be increased to the amount specified in Row C only pursuant to Section 93-31 (District Improvement Fund Bonus) or as otherwise specified in Sections 93-221 through 93-224.
For a zoning lot with more than one building, the basic maximum floor area ratios set forth in Row A shall apply, provided that any building that is developed or enlarged after January 19, 2005, is wholly non-residential. If a building containing residences is developed or enlarged on such a zoning lot after January 19, 2005, the basic maximum floor area ratios set forth in Row B shall apply.
Notwithstanding the provisions of this Section, the basic maximum permitted floor area ratio may be increased on an "adjacent lot" pursuant to Section 74-79 (Transfer of Development Rights From Landmark Sites), provided that the maximum floor area transferred from the landmark lot does not exceed the basic maximum permitted floor area ratio less the total floor area of all buildings on the landmark lot.
Maximum Permitted Floor Area Ratio within Subdistricts B through E
Farley Corridor Subdistrict B | 34th St Corridor Sub district C | Hell's Kitchen Subdistrict D | South of Port Auth. Sub district E | ||||||
Subarea | Western Blocks | Central Blocks | Farley Post Office | Penn. Stn. | Subarea D1 | Subarea D2 | Subarea D3 | ||
ROW A Basic maximum FAR for non-residential buildings | 10.0 total 10.0 C 2.0 CF | 12.0 total 12.0 C 2.0 CF | 10.0 total 10.0 C 2.0 CF | 10.0 total 10.0 C 2.0 CF | 10.0 total 10.0 C 10.0 CF | 7.5 total 2.0 C 7.5 CF | 7.5 total 2.0 C 7.5 CF | 7.5 total 6.0 C 7.5 CF | 10.0 total 10.0 C 2.0 CF |
ROW B Basic maximum FAR for buildings containing residences | NA | NA | 10.0 total 10.0 C 6.0 R 2.0 CF | NA | 6.5 total 6.5 C 6.5 R 6.5 CF | 6.5 total 2.0 C 6.5 R 6.5 CF | 6.5 total 2.0 C 6.5 R 6.5 CF | 7.5 total 6.0 C 7.5 R 7.5 CF | NA |
ROW C Maximum FAR through special floor area increases pursuant to Section 93-30, inclusive, Inclusionary Housing Section 93-23, inclusive, or Section 74-79, inclusive, as applicable. | 21.6 total 21.6 C 6.0 R 2.0 CF | 19.0 total 19.0 C 4.0 R 2.0 CF | NA | 19.5 total 19.5 C 2.0 CF | 13.0 total 13.0 C 12.0 R 12.0 CF | 15.0 total 3.0 C 12.0 R 12.0CF | 13.0 total 3.0 C 12.0 R 12.0CF | 12.0 total 7.5 R 7.2 C 12.0CF | 18.0 total 18.0 C 3.0 R 2.0 CF |
C = Commercial FAR
CF = Community Facility FAR
R = Residential FAR
(b) Subdistrict F
In Subdistrict F, the floor area ratio provisions of Section 93-225 (Floor area regulations in Subdistrict F) shall apply.
In Subdistrict F, the floor area ratio provisions of Section 93-225 (Floor area regulations in Subdistrict F) shall apply.
(c) Subdistrict G
In Subdistrict G, the floor area ratio provisions of Section 93-226 (Floor area regulations in Subdistrict G) shall apply.
In Subdistrict G, the floor area ratio provisions of Section 93-226 (Floor area regulations in Subdistrict G) shall apply.
- Western Blocks Subarea B1
In the Western Blocks Subarea B1 of Farley Corridor Subdistrict B, residential use shall only be permitted on a zoning lot with a commercial floor area ratio of 12.0 or more, or as provided for phased developments in Section 93-122 (Certification for residential use in Subdistricts A, B and E). - Central Blocks Subarea B2
In the Central Blocks Subarea B2 of Farley Corridor Subdistrict B, residential use shall only be permitted on a zoning lot with a commercial floor area ratio of 15.0 or more, or as provided for phased developments in Section 93-122. - Farley Post Office Subarea B3
In the Farley Post Office Subarea B3 of Farley Corridor Subdistrict B, no floor area increases shall be permitted. - Pennsylvania Station Subarea B4
In the Pennsylvania Station Subarea B4 of Farley Corridor Subdistrict B, any increase in the floor area ratio specified in Row A in the table in Section 93-22 shall be permitted only pursuant to Section 93-35 (Special Permit for Transit Bonus in Pennsylvania Station Subarea B4) and Section 74-79 (Transfer of Development Rights From Landmark Sites), as modified by paragraph (b) of Section 93-054 (Applicability of Article VII, Chapter 4). - Transfer of floor area
Notwithstanding any other provision of this Resolution, floor area may not be transferred between a zoning lot located north of West 31st Street in the Western Blocks Subarea B1 and a zoning lot located north of West 31st Street in the Central Blocks Subarea B2.
In the 34th Street Corridor Subdistrict C, the basic maximum floor area ratios of non-residential buildings are set forth in Row A in the table in Section 93-22 and may be increased to the amount specified in Row C pursuant to Section 93-31 (District Improvement Fund Bonus). The basic maximum floor area ratios of any building containing residences are set forth in Row B.
The floor area ratio of any building containing residences may be increased from 6.5, pursuant to Sections 93-31 (District Improvement Fund Bonus) and 23-154 (Inclusionary Housing), as modified by Section 93-23 (Modifications of Inclusionary Housing Program), as follows:
- the residential floor area ratio may be increased from 6.5 to a maximum of 12.0 only if for every five square feet of floor area increase, pursuant to Section 93-31, there is a floor area increase of six square feet, pursuant to Section 23-154, as modified by Section 93-23; and
- any floor area increase above a floor area ratio of 12.0 shall be only pursuant to Section 93-31.
For developments or enlargements on qualifying transit improvement sites, a floor area bonus for mass transit station improvements may be granted by the City Planning Commission pursuant to the provisions of Section 66-51 (Additional Floor Area for Mass Transit Station Improvements). As a pre-condition to applying for such floor area bonus, the applicant shall demonstrate that a floor area ratio of no less than 0.1 of the maximum floor area ratio set forth in Row C of Section 93-22 (Floor Area Regulations in Subdistricts B, C, D, E, and F), has been achieved prior to, or in conjunction with, the application. For the purposes of this paragraph, defined terms additionally include those in Section 66-11 (Definitions).
- Subareas D1 and D2
In Subareas D1 and D2 of Hell's Kitchen Subdistrict D, the basic maximum floor area ratios of non-residential buildings are set forth in Row A in the table in Section 93-22 and may be increased to the amount specified in Row C pursuant to Section 93-31 (District Improvement Fund Bonus) or through the transfer of floor area from the Phase 2 Hudson Boulevard and Park as set forth in Section 93-32. The basic maximum floor area ratios of any building containing residences are set forth in Row B.
The floor area ratio of any building containing residences may be increased from 6.5 pursuant to Section 93-31 (District Improvement Fund Bonus) or through the transfer of floor area from the Phase 2 Hudson Boulevard and Park as set forth in Section 93-32, and pursuant to Section 23-154 (Inclusionary Housing), as modified by Section 93-23, as follows:
The residential floor area ratio may be increased from 6.5 to a maximum of 12.0 only if for every five square feet of floor area increase pursuant to Sections 93-31 or 93-32 there is a floor area increase of six square feet, pursuant to Section 23-154, as modified by Section 93-23.Any floor area increase above a floor area ratio of 12.0 shall be only pursuant to Sections 93-31 or 93-32.Furthermore, in Subarea D1, the floor area ratio on a zoning lot may exceed 13.0 only where the community facility floor area ratio is not less than the excess of such floor area ratio above 13.0. - Subarea D3
In Subarea D3, the basic maximum floor area ratio may be increased only pursuant to Section 93-31. - Subareas D4 and D5
In Subareas D4 and D5, the underlying floor area ratio regulations shall apply. - Authorization for transfer of floor area for public facilities
For any zoning lot located partially in Subarea D2 and partially in Subarea D4, where such zoning lot is occupied by a development or enlargement that includes a public facility, the City Planning Commission may authorize modifications to the street wall requirements of Subarea D4 and authorize modifications to the provisions of Section 77-22 (Floor Area Ratio) in order to allow the transfer of floor area from that portion of the zoning lot located in Subarea D4 to that portion located in Subarea D2, provided the floor area ratio for the zoning lot does not exceed the adjusted maximum floor area ratio for the zoning lot as specified in Section 77-22. In order to authorize such modifications, the Commission shall find that:- such public facility provides a necessary service to the surrounding area;
- such transfer of floor area is necessary in order for the development or enlargement to achieve an adequate separation of uses on the zoning lot; and
- such transfer of floor area will not unduly increase the bulk of any development or enlargement, density of population or intensity of use to the detriment of occupants of buildings on the block or surrounding blocks, and that any disadvantages to the surrounding area caused by reduced access of light and air will be more than offset by the advantages of the public facility to the local community and the City as a whole.
- Authorization for transfer of floor area for public open areas
For developments or enlargements on zoning lots divided by district boundaries that are wholly or partially within Hell's Kitchen Subdistrict D and provide publicly accessible open areas contiguous to or over the Lincoln Tunnel Approaches or Dyer Avenue, the Commission may authorize the distribution of floor area across such district boundaries pursuant to Section 93-543 (Authorization for the provision of public open areas).
In the South of Port Authority Subdistrict E, residential use shall only be permitted as part of a development or enlargement on a zoning lot with a commercial floor area ratio of 15.0 or more, or as provided for phased developments in Section 93-122 (Certification for residential use in Subdistricts A, B and E).
For developments or enlargements on qualifying transit improvement sites, a floor area bonus for mass transit station improvements may be granted by the City Planning Commission pursuant to the provisions of Section 66-51 (Additional Floor Area for Mass Transit Station Improvements). As a pre-condition to applying for such floor area bonus, the applicant shall demonstrate that a floor area ratio of no less than 0.1 of the maximum floor area ratio set forth in Row C of Section 93-22 (Floor Area Regulations in Subdistricts B, C, D, E, and F), has been achieved, prior to, or in conjunction with, the application. For the purposes of this paragraph, defined terms additionally include those in Section 66-11 (Definitions).
In Subdistrict F, the maximum floor area ratio for residential, community facility and commercial uses on a zoning lot shall be as follows:
- the maximum floor area ratio for residential uses shall be 8.0;
- the maximum floor area ratio for community facility uses shall be 2.0. However, any floor space occupied by a public school, constructed in whole or in part pursuant to agreement with the New York City School Construction Authority and subject to the jurisdiction of the New York City Department of Education, shall be exempted from the definition of floor area for the purposes of calculating the permitted floor area ratio for community facility uses and the total maximum floor area ratio of the zoning lot;
- the maximum floor area ratio for commercial uses shall be 8.0; and
- the total maximum floor area ratio in the subdistrict shall be 10.0, except as modified pursuant to Section 93-23 (Modifications of Inclusionary Housing Program).
In Subdistrict G, the basic maximum permitted floor area ratio for residential, community facility, and commercial uses on a zoning lot shall be as follows:
- the maximum floor area ratio for residential uses shall be 12.0, pursuant to Section 23-154 (Inclusionary Housing);
- the maximum floor area ratio for community facility uses shall be 12.0;
- the maximum floor area ratio for commercial uses shall be 12.0; and
- the total maximum floor area ratio shall be 24.0.
Subdistrict C (34th Street Corridor) and Subareas D1 and D2 of Subdistrict D (Hell's Kitchen) of the Special Hudson Yards District and Subdistrict A-2 of the Special Garment Center District, shall be Inclusionary Housing designated areas, pursuant to Section 12-10 (DEFINITIONS) for the purpose of making the Inclusionary Housing Program regulations of Sections 23-154 (Inclusionary Housing) and 23-90 (INCLUSIONARY HOUSING), inclusive, applicable as modified within the Special Districts. The underlying provisions of Sections 23-154 and 23-90 shall only be applicable in Subdistrict F as modified by Section 93-233 (Floor area increase for affordable housing in Subdistrict F).
For the purposes of this Chapter, matter in italics is defined in Section 12-10 or 23-911 (General definitions), inclusive.
Within Subdistricts B, C, D and E, and Subdistrict A-2 of the Special Garment Center District, the provisions of Section 23-154 (Inclusionary Housing) shall not apply. In lieu thereof, the floor area compensation provisions of this Section shall apply. In accordance with the provisions set forth in Section 93-22 (Floor Area Regulations in Subdistricts B, C, D, E and F) or 121-41 (Maximum Permitted Floor Area Within Subdistrict A-2), the maximum permitted residential floor area ratio on a zoning lot with developments or enlargements that provide affordable housing pursuant to the Inclusionary Housing Program may be increased, as follows:
- The permitted floor area ratio may be increased from 6.5, or as otherwise specified in Section 93-22, to a maximum of 9.0, provided that:
- the amount of low income floor area is equal to at least 10 percent of the total residential floor area on the zoning lot; or
- the amount of low income floor area is equal to at least five percent of the total residential floor area on the zoning lot, and the amount of moderate income floor area is equal to at least 7.5 percent of the total residential floor area on the zoning lot; or
- the amount of low income floor area is equal to at least five percent of the total residential floor area on the zoning lot and the amount of middle income floor area is equal to at least 10 percent of the total residential floor area on the zoning lot.
- The permitted floor area ratio may be increased from 9.0 to a maximum of 12.0, provided that:
- the amount of low income floor area is equal to at least 20 percent of the total residential floor area on the zoning lot; or
- the amount of low income floor area is equal to at least 10 percent of the total residential floor area on the zoning lot, and the amount of moderate income floor area is equal to at least 15 percent of the total residential floor area on the zoning lot; or
- the amount of low income floor area is equal to at least 10 percent of the total residential floor area on the zoning lot and the amount of middle income floor area is equal to at least 20 percent of the total residential floor area on the zoning lot.
For the purposes of this Section, low income floor area may be considered moderate income floor area or middle income floor area, and moderate income floor area may be considered middle income floor area.
The floor area of any building containing residences in Subdistrict F may be increased by up to five percent, and such increase may be in excess of the maximum floor area ratio of 8.0 for residential use, and the total maximum floor area ratio of 10.0, provided that:
- at least 20 percent of the residential units in such building, inclusive of any floor area increase permitted by this Section, shall be occupied by low income households, as defined in Section 23-911 (General definitions);
- such building shall comply with the provisions of:
- Section 23-953 (Additional requirements for compensated developments and MIH developments);
- Section 23-96 (Requirements for Generating Sites or MIH Sites), paragraphs (b) through (i); and;
- Section 23-961 (Additional requirements for rental affordable housing), paragraphs (a) through (d); and
- the sum of all floor area increases permitted pursuant to this Section does not exceed 0.4 times the total lot area of Subdistrict F.
In Subdistrict A-2 of the Special Garment Center District and in the Special Hudson Yards District, except in Subdistrict F, the Chairperson of the City Planning Commission shall allow, by certification, the applicable basic maximum floor area ratio to be increased up to the maximum amount specified in Sections 93-21, 93-22 or 121-31, as applicable, provided that instruments in a form acceptable to the City are executed and recorded and that, thereafter, a contribution has been deposited in the Hudson Yards District Improvement Fund. The execution and recording of such instruments and the payment of such non-refundable contribution shall be a precondition to the filing for or issuing of any building permit allowing more than the basic maximum floor area for such development or enlargement.
The Commissioner of Buildings shall not authorize the construction of any development or enlargement utilizing floor area bonused pursuant to this Section, including foundations with respect thereto, nor shall the construction of any bonused portion thereof be authorized, until the Chairperson has certified that the requirements of this Section have been met. Nothing herein shall limit the ability of the Commissioner of Buildings to issue a permit for the construction of a development or enlargement which does not utilize such bonused floor area, provided that, prior to issuance of such permit, the Chairperson has notified the Commissioner of Buildings in writing of the receipt by the Department of City Planning of either:
- a letter from the applicant for such permit dated no earlier than 30 days prior to issuance thereof, stating whether as of such date the applicant anticipates filing an application to increase the applicable basic maximum floor area ratio pursuant to the provisions of this Section and/or Section 23-154 (Inclusionary Housing), as modified by Section 93-23 (Modifications of Inclusionary Housing Program); or
- an application for a bonus from such applicant to increase the applicable basic maximum floor area ratio pursuant to the provisions of this Section and/or Section 23-154, as modified by Section 93-23.
Copies of letters received from applicants pursuant to paragraph (a) of this Section shall be forwarded by the Department of City Planning to the Community Board and local City Council member, and maintained on file and be available for public inspection at such Department.
The contribution amount shall be $100 per square foot of floor area as of January 19, 2005, and shall be adjusted by the Chairperson annually. Such adjustment shall occur on August 1 of each calendar year, based on the percentage change in the Consumer Price Index for all urban consumers as defined by the U.S. Bureau of Labor Statistics for the twelve months ended on June 30 of that year. The contribution amount shall be determined based upon the rate which is in effect at the time the contribution is received, and contributions may be made only on days when the Hudson Yards Infrastructure Corporation (the "Corporation") is open for business and during business hours as specified by the Corporation.
The Commission may promulgate rules regarding the administration of this Section, and the Commission may also, by rule, adjust the contribution amount specified in the preceding paragraph to reflect changes in market conditions within the Hudson Yards Redevelopment Area if, in its judgment, the adjusted amount will facilitate the district-wide improvements that are consistent with the purposes of this Chapter and the purposes of the Special Garment Center District. The Commission may make such an adjustment by rule, not more than once a year.
For any such adjustment by rule decreasing the contribution amount, or increasing the contribution amount by more than the percentage change in the Consumer Price Index for all urban consumers, the following shall apply:
- Such rule shall be effective for not more than two years; and
- The Commission shall not publish the proposed rule pursuant to the City Administrative Procedure Act unless the City Council Land Use Committee and the Department of City Planning have jointly filed an application for a zoning text amendment under Section 201 of the New York City Charter, which would make such adjustment of the contribution amount permanently effective. The contribution amount established under such rule as finally adopted shall continue in effect with further adjustments based upon the Consumer Price Index for all urban consumers, until the next adjustment of the contribution amount pursuant to this Section.
For the conversion to dwelling units of non-residential floor area, where the total floor area on the zoning lot to be converted to residential use exceeds a floor area ratio of 12.0, such excess floor area shall be permitted only pursuant to the provisions of this Section.
In the Phase 2 Hudson Boulevard and Park, no development shall be permitted and, except as provided in Section 93-051 (Applicability of Article I, Chapter 1), no building shall be enlarged. However, floor area from a granting site within the Phase 2 Hudson Boulevard and Park may be transferred to a receiving site in accordance with the provisions of paragraph (a) of this Section.
For the purposes of this Section, a "granting site" shall mean a zoning lot, or portion thereof, within the Phase 2 Hudson Boulevard and Park and the lot area of such granting site shall include any area on such site designated on the City Map as Hudson Boulevard or public park, and a "receiving site" shall mean a zoning lot, or portion thereof, within Subareas A2 through A5 of the Large-Scale Plan Subdistrict A or Subareas D1 or D2 of Hell's Kitchen Subdistrict D, to which floor area from a granting site has been transferred.
Special regulations for certain zoning lots partially within the Phase 2 Hudson Boulevard and Park are set forth in Section 93-33.
(a) Transfer of floor area by certification
The Chairperson of the City Planning Commission shall allow, by certification, the applicable basic maximum floor area ratio of a receiving site to be increased up to the maximum amount specified in Section 93-21 or 93-22, as applicable, through the transfer of floor area from a granting site, provided that:
The Chairperson of the City Planning Commission shall allow, by certification, the applicable basic maximum floor area ratio of a receiving site to be increased up to the maximum amount specified in Section 93-21 or 93-22, as applicable, through the transfer of floor area from a granting site, provided that:
(1) the maximum amount of floor area transferred from a granting site shall not exceed the floor area ratio permitted on the granting site, as listed below, less any existing floor area to remain on the granting site:
District | Maximum floor area ratio |
C2-8 | 7.5 |
C6-2 | 6.02 |
C6-4 | 10.0 |
M1-5 | 5.0 |
(2) each transfer, once completed, irrevocably reduces the amount of floor area that may be transferred from the granting site by the amount of floor area transferred;
(3) the maximum amount of floor area transferred to a receiving site shall be based on an amount not to exceed the floor area ratio permitted on a zoning lot through such transfer pursuant to Section 93-21 or 93-22, as applicable. In the event a granting site generates more floor area than is permitted on a receiving site, the Chairperson shall certify that such excess floor area be credited towards future floor area transfers pursuant to this Section; and
(4) where all floor area shall be transferred from a granting site pursuant to one or more such certifications, all certificates of occupancy have been surrendered for such granting site, all structures on such granting site have been demolished, and such granting site has been conveyed to the City for improvement, where applicable, as a public park or street, as provided for on the City Map.
Where, as a result of the transfer of floor area pursuant to this paragraph (a), the amount of floor area on a receiving site is less than the maximum allowable as specified for the applicable subarea in Row B in the table in Section 93-21 and Row C in the table in Section 93-22, any additional floor area, up to the maximum floor area ratio permitted on the receiving site as specified in such rows, may be achieved only through contributions to the Hudson Yards District Improvement Fund pursuant to Section 93-31 (District Improvement Fund Bonus), an increase in floor area pursuant to paragraph (b) of this Section or Section 93-33 (Special Regulations for Residual Portions of Zoning Lots Partially Within the Phase 2 Hudson Boulevard and Park), or the Inclusionary Housing Program pursuant to Section 23-154, as modified by Section 93-23.
An application filed with the Chairperson for the transfer of floor area pursuant to this paragraph (a) shall be made jointly by the owners of the granting site and receiving site, and shall include a site plan and floor area zoning calculations for the granting site and the receiving site, and a copy of the transfer instrument legally sufficient in both form and content to effect such a transfer, together with notice of the restrictions upon further development of the granting site and the receiving site.
Notices of restrictions shall be filed by the owners of the granting site and receiving site in the Borough Office of the Register of the City of New York, indexed against the granting site and the receiving site, a certified copy of which shall be submitted to the Chairperson of the Commission. Receipt of certified copies thereof shall be a pre-condition to issuance of any building permit, including any foundation or alteration permit, for any development or enlargement on the receiving site which incorporates floor area transferred pursuant to this paragraph (a).
An application filed with the Chairperson for the transfer of floor area pursuant to this paragraph (a) shall be made jointly by the owners of the granting site and receiving site, and shall include a site plan and floor area zoning calculations for the granting site and the receiving site, and a copy of the transfer instrument legally sufficient in both form and content to effect such a transfer, together with notice of the restrictions upon further development of the granting site and the receiving site.
Notices of restrictions shall be filed by the owners of the granting site and receiving site in the Borough Office of the Register of the City of New York, indexed against the granting site and the receiving site, a certified copy of which shall be submitted to the Chairperson of the Commission. Receipt of certified copies thereof shall be a pre-condition to issuance of any building permit, including any foundation or alteration permit, for any development or enlargement on the receiving site which incorporates floor area transferred pursuant to this paragraph (a).
(b) Authorization for contribution-in-kind
The City Planning Commission may authorize a contribution-in-kind to the Hudson Yards District Improvement Fund for a receiving site, provided that:
The City Planning Commission may authorize a contribution-in-kind to the Hudson Yards District Improvement Fund for a receiving site, provided that:
(1) the conditions for transferring floor area set forth in paragraph (a) of this Section have been met as of the date of the authorization or will be met in accordance with agreements or instruments entered into pursuant to paragraph (b)(3) of this Section;
(2) the granting site will be improved, at the applicant's expense, as a public park or street, as provided for on the City Map, prior to conveyance to the City; and
(3) the applicant, or an affiliate of such applicant, has entered into an agreement or provided instruments in a form satisfactory to the City, providing for the improvement of the granting site as a public park or street pursuant to an agreed-upon construction schedule. The construction schedule may be adjusted from time to time in accordance with the provisions of such agreement or instruments and shall include progress milestones, including the date by which the improvements will be 50 percent complete, and a date by which the improvements will be substantially complete and usable by the public. In the event that the conditions for transferring floor area set forth in paragraph (a) of this Section have not been completed as of the date of this authorization, such agreement or instruments shall also provide that such conditions will be met, to the extent applicable, pursuant to an agreed-upon schedule.
In order to grant such authorization, the Commission shall find that the public park or street has been designed in accordance with the approved plan for the Hudson Boulevard and Park, or as an appropriate interim design, in consultation with the Department of Parks and Recreation or Department of Transportation.
The Commission shall determine the reasonable cost of such improvement, including any acquisition and site preparation costs, and shall divide this reasonable cost by the contribution amount per square foot of the District Improvement Bonus, as determined pursuant to Section 93-31, and in effect on the date of authorization of the contribution-in-kind pursuant to this paragraph (b), in order to determine the amount of increased floor area generated by the contribution-in-kind. In making such determination, the Commission may consult with an appraiser or engineer at the applicant's expense. In the event the contribution-in-kind results in an amount of floor area in excess of what is permitted on the receiving site, the Commission shall authorize that such excess floor area be credited towards future floor area increases pursuant to Section 93-31.
The owner of the receiving site shall not apply for or accept a temporary certificate of occupancy for that portion of the development or enlargement identified as utilizing the increased floor area permitted pursuant to this paragraph (b), and the Department of Buildings shall not issue a temporary certificate of occupancy for such portion until the Chairperson has certified that the improvements are substantially complete and usable by the public. The owner shall not apply for or accept a permanent certificate of occupancy for such portion of the development or enlargement nor shall the Department of Buildings issue a permanent certificate of occupancy for such portion until the improvements have been finally completed in accordance with the approved plans and such final completion has been certified by the Chairperson. A restrictive declaration in a form acceptable to the Chairperson shall be recorded against the receiving site in the Office of the Register of the City of New York in order to implement such restrictions.
An application filed with the Chairperson for the contribution-in-kind pursuant to this paragraph (b) shall be made jointly by the owners or contract vendees of the granting site and receiving site and shall, in all instances, include the party responsible either directly or through its affiliate, for the improvement of the granting site as a public park or street pursuant to the agreement or instruments entered into pursuant to paragraph (b)(3) of this Section.
Receipt of executed copies of the agreement or instruments required pursuant to paragraph (b)(3) of this Section, and of copies of the recorded restrictive declaration, shall be a precondition to the issuance of a building permit, including any foundation or alteration permit, for any development or enlargement on the receiving site that incorporates a floor area bonus granted pursuant to this paragraph (b).
In no event shall a building permit for a development or enlargement utilizing a floor area increase pursuant to this paragraph (b) be granted for the receiving site until the Chairperson provides notice to the Commissioner of Buildings that the applicant, or affiliate responsible for the improvement of the granting site, has provided acceptable evidence of site control for purposes of construction of the improvement.
The owner of the receiving site shall not apply for or accept a temporary certificate of occupancy for that portion of the development or enlargement identified as utilizing the increased floor area permitted pursuant to this paragraph (b), and the Department of Buildings shall not issue a temporary certificate of occupancy for such portion until the Chairperson has certified that the improvements are substantially complete and usable by the public. The owner shall not apply for or accept a permanent certificate of occupancy for such portion of the development or enlargement nor shall the Department of Buildings issue a permanent certificate of occupancy for such portion until the improvements have been finally completed in accordance with the approved plans and such final completion has been certified by the Chairperson. A restrictive declaration in a form acceptable to the Chairperson shall be recorded against the receiving site in the Office of the Register of the City of New York in order to implement such restrictions.
An application filed with the Chairperson for the contribution-in-kind pursuant to this paragraph (b) shall be made jointly by the owners or contract vendees of the granting site and receiving site and shall, in all instances, include the party responsible either directly or through its affiliate, for the improvement of the granting site as a public park or street pursuant to the agreement or instruments entered into pursuant to paragraph (b)(3) of this Section.
Receipt of executed copies of the agreement or instruments required pursuant to paragraph (b)(3) of this Section, and of copies of the recorded restrictive declaration, shall be a precondition to the issuance of a building permit, including any foundation or alteration permit, for any development or enlargement on the receiving site that incorporates a floor area bonus granted pursuant to this paragraph (b).
In no event shall a building permit for a development or enlargement utilizing a floor area increase pursuant to this paragraph (b) be granted for the receiving site until the Chairperson provides notice to the Commissioner of Buildings that the applicant, or affiliate responsible for the improvement of the granting site, has provided acceptable evidence of site control for purposes of construction of the improvement.
Where all of the lot area within the following parcels, as they existed on January 19, 2005, that is also within the Phase 2 Hudson Boulevard and Park, has been conveyed to the City pursuant to the provisions of Section 93-32, the owner of the residual portion of one of these parcels may convey to the City such residual portion, with all development rights appurtenant thereto, provided that all certificates of occupancy have been surrendered and all structures on such parcel have been demolished:
Block 708, Lots 20 and 46
Block 709, Lot 17
Block 710, Lot 20.
When such conveyance is made, the Chairperson of the City Planning Commission may certify that such owner is entitled to an increase in floor area on any receiving site as specified in Section 93-32, in lieu of a permitted floor area increase in exchange for contributions to the Hudson Yards District Improvement Fund. The amount of increase certified shall not exceed the lot area of the residual portion times the floor area ratio of the applicable zoning district, as specified in Section 93-32, paragraph (a)(1).
The maximum amount of floor area increase on a receiving site shall be based on an amount not to exceed the floor area ratio increase permitted on a zoning lot through such contribution pursuant to Sections 93-21 or 93-22, as applicable. In the event the certified permissible floor area increase is greater than that permitted on a receiving site, the Chairperson shall certify that such excess floor area be credited towards future floor area increases on receiving sites pursuant to this Section.
Once certified by the Chairperson, the entitlement to an increase in floor area pursuant to this Section shall be the property of the former owner of the residual property conveyed to the City, and such owner may assign, sell or otherwise transfer such entitlement without restriction.
Where certification is made pursuant to this Section, the site plan and floor area calculations for the receiving site, together with the notice of restrictions upon further development of the receiving site, included in the application submitted pursuant to Section 93-32, shall set forth the increase in floor area for such receiving site certified hereunder.
In order to promote a superior site plan in the Eastern Rail Yard Subarea A1 of the Large-Scale Plan Subdistrict A, the Chairperson of the City Planning Commission shall allow, by certification, the distribution of floor area from the Eastern Rail Yard Subarea A1 to zoning lots in Subareas A2 through A5 of the Large-Scale Plan Subdistrict A. Such distribution shall only be permitted for receiving sites that have maximized their permitted floor area through contributions to the Hudson Yards District Improvement Fund, pursuant to Section 93-31, or the transfer of floor area or increase in the amount of floor area from the Phase 2 Hudson Boulevard and Park, pursuant to Sections 93-32 or 93-33. For the purposes of this Section, a "receiving site" shall mean a zoning lot within Subareas A2 through A5 to which floor area from the Eastern Rail Yard Subarea A1 has been distributed.
- Distribution of floor area by certification
The Chairperson of the Commission shall allow, by certification, a distribution of floor area from the Eastern Rail Yard Subarea A1 to a receiving site provided that:- The amount of floor area distributed does not result in distributions in excess of the maximum amount specified for the applicable use that may be distributed from the Eastern Rail Yard Subarea A1, as set forth in paragraph (b)(2) of Section 93-21;
- Each distribution, once completed, irrevocably reduces the amount of floor area that may be distributed from the Eastern Rail Yard Subarea A1 by the amount of floor area distributed; and
- The amount of floor area on the receiving site which results from such distribution does not exceed the maximum floor area ratio permitted on a zoning lot through distribution of floor area from the Eastern Rail Yard Subarea A1, as specified in Row C of the table in Section 93-21.
- Requirements for application
An application filed with the Chairperson of the Commission for the distribution of floor area by certification pursuant to paragraph (a) of this Section shall be made jointly by the owner of the development rights of the Eastern Rail Yard Subarea A1 and the receiving site and shall include:
- a site plan and floor area zoning calculations for the receiving site; and
- a copy of the distribution instrument legally sufficient in both form and content to effect such a distribution, together with a notice of the restrictions limiting further development of the Eastern Rail Yard Subarea A1.
Such notice of restrictions shall be filed by the owners of the respective sites in the Borough Office of the Register of the City of New York, indexed against the Eastern Rail Yard Subarea A1 and the receiving site, a certified copy of which shall be submitted to the Chairperson of the Commission. Receipt of certified copies thereof shall be a pre-condition to issuance of any building permit for any development or enlargement utilizing floor area distributed pursuant to this Section, including foundations with respect thereto, on the receiving site. Nothing herein shall limit the ability of the Commissioner of Buildings to issue a permit for the construction of a development or enlargement which does not utilize such distributed floor area.
In the Pennsylvania Station Subarea B4, for developments or enlargements that significantly enhance the pedestrian environment and provide improvements to access to public transit facilities, the City Planning Commission may permit a commensurate floor area increase for commercial use above a floor area ratio of 10.0 to a maximum floor area ratio of 19.5.
- The following conditions shall apply:
- the applicant shall submit a plan acceptable to the Commission identifying that portion of the development or enlargement utilizing such increased floor area;
- all transit facility improvements shall comply with applicable design standards or the current guidelines of the Metropolitan Transit Authority, New Jersey Transit, or Amtrak, as applicable;
- the applicant shall submit schematic or concept plans for all proposed improvements to the applicable transportation agency and the Commission, and any further documentation deemed necessary by the reviewing agencies;
- the Commission shall receive a letter from the applicable transportation agency stating the drawings and other documents submitted by the applicant have been determined to be of sufficient scope and detail to fix and describe the size and character of the transit improvement as to architectural, structural, mechanical and electrical systems; materials; relationship to existing site conditions; and other such elements as may be appropriate; and
- the owner shall sign a legally enforceable instrument in a form acceptable to the reviewing agencies containing complete drawings of the improvement and setting forth the obligations of owner and developer, their successors and assigns, to construct and maintain all parts of the improvement, whether on-site or off, pursuant to an agreed-upon construction schedule. Such instrument shall be recorded against the zoning lot in the Office of the Register of the City of New York for New York County and a certified copy of the instrument shall be submitted to the Chairperson of the Commission and the applicable transportation agencies.
The owner shall not apply for or accept a temporary certificate of occupancy for that portion of the development or enlargement identified as utilizing the increased floor area permitted pursuant to this Section, and the Department of Buildings shall not issue a temporary certificate of occupancy for such portion, until the applicable transportation agencies have certified that the transit facility improvement is substantially complete and usable by the public. The owner shall not apply for or accept a permanent certificate of occupancy for such portion of the development or enlargement, nor shall the Department of Buildings issue a permanent certificate of occupancy for such portion until the transit improvement has been finally completed in accordance with the approved plans and such final completion has been certified by the applicable transportation agencies.
- In order to grant such special permit, the Commission shall find that:
- the transit improvements significantly enhance the surface and subsurface pedestrian circulation network into and around the development or enlargement and to and from public transit facilities;
- the streetscape, the site design and the location of building entrances for the development or enlargement contribute to the overall improvement of pedestrian circulation within the Special Hudson Yards District and minimize congestion on surrounding streets; and
- the increased floor area will not unduly increase the bulk of the development or enlargement, density of population or intensity of use to the detriment of the occupants of buildings in the surrounding area.
In determining the amount of floor area bonus, the Commission shall consider the extent to which the transit improvements address each of the above findings.
The Commission may prescribe appropriate additional conditions and safeguards in order to enhance the character of the development or enlargement and to minimize adverse effects on the character of the surrounding area.
In the Special Hudson Yards District, height and setback regulations shall be as set forth in this Section, inclusive.
- Subdistricts A, B, C, D, E and G
The provisions of Section 33-42 (Permitted Obstructions) shall apply to all buildings within Subdistricts A through E and G, except that dormers may penetrate a maximum base height in accordance with the provisions of paragraph (c)(1) of Section 23-621 (Permitted obstructions in certain districts). - Subdistrict F
In Subdistrict F, the provisions of paragraph (f) of Section 33-42 shall apply, except that for towers above a height of 350 feet, rooftop mechanical structures shall comply with the tower top articulation provisions set forth in Section 93-569.
In Subareas D4 and D5 of the Hell's Kitchen Subdistrict D, the underlying height and setback regulations shall apply as set forth in Section 93-542, as modified by Section 93-41 (Rooftop Regulations).
In Subdistricts A, B and C, Subareas D1, D2 and D3 of the Hell's Kitchen Subdistrict D, and Subdistrict E, the underlying height and setback regulations shall not apply. In lieu thereof, the provisions of Section 93-41 and paragraphs (a) through (d) of this Section shall apply. These regulations are further modified in certain locations as set forth in Section 93-50 (SPECIAL HEIGHT,SETBACK AND YARD REGULATIONS). The height of all buildings or other structures shall be measured from curb level.
In Subdistrict F, the underlying height and setback regulations shall not apply. In lieu thereof, the provisions of Section 93-41 and Section 93-56 (Special Height and Setback Regulations in Subdistrict F) shall apply.
In Subdistrict G, the underlying height and setback regulations and paragraphs (b) through (d) of this Section shall not apply. In lieu thereof, Section 93-57 (Special Height and Setback Regulations in Subdistrict G) shall apply.
- Maximum base heights
The maximum height of a building or other structure before setback shall be 150 feet along a wide street and along a narrow street within 100 feet of its intersection with a wide street, and 90 feet along a narrow street beyond 100 feet of its intersection with a wide street. For corner lots with wide street frontage and more than 100 feet of narrow street frontage, the maximum building height before setback along the narrow street may, as an alternative, be the weighted average of 150 feet for the first 100 feet from the corner, and 90 feet for the remainder of the narrow street frontage. Such allowable maximum heights before required setbacks are hereinafter referred to as "maximum base heights." - Required setbacks
For buildings that contain only residential use above the applicable maximum base height, the required minimum setback for portions of such buildings that exceed such maximum base height shall be 10 feet from a wide street and 15 feet from a narrow street.
For buildings or other structures that contain commercial or community facility use above the applicable maximum base height, the required minimum setback for portions of buildings or other structures that exceed such maximum base height shall be 15 feet from a wide street and 20 feet from a narrow street. - Tower lot coverage
The portion of any building or buildings located above a height of 150 feet are hereinafter referred to as "towers."- Towers containing residences shall occupy, in the aggregate, a minimum of 30 percent of the lot area of the zoning lot, except that this requirement shall not apply to the highest 40 feet of such tower or towers. Furthermore, towers containing residences shall occupy not more than 40 percent of the lot area of the zoning lot or, for zoning lots less than 20,000 square feet, the percentage set forth in the following table:LOT COVERAGE OF TOWERS ON SMALL ZONING LOTSArea of Zoning Lot (in square feet)Maximum Percentage of Lot Coverage10,500 or less5010,501 to 11,5004911,501 to 12,5004812,501 to 13,5004713,501 to 14,5004614,501 to 15,5004515,501 to 16,5004416,501 to 17,5004317,501 to 18,5004218,501 to 19,99941
- Towers that contain only commercial or community facility use, or a combination thereof, shall occupy not more than 60 percent of the lot area of the zoning lot or, for zoning lots less than 30,000 square feet, the percentage set forth in the following table:LOT COVERAGE OF TOWERS ON SMALL ZONING LOTSArea of Zoning Lot (in square feet)Maximum Percentage of Lot Coverage20,500 or less7020,501 to 21,5006921,501 to 22,5006822,501 to 23,5006723,501 to 24,5006624,501 to 25,5006525,501 to 26,5006426,501 to 27,5006327,501 to 28,5006228,501 to 29,99961
- Length of building wall
The maximum length of any story located above a height of 500 feet shall not exceed 250 feet. Such length shall be measured by inscribing within a rectangle the outermost walls at the level of each story entirely above a height of 500 feet. No side of such rectangle shall exceed a width of 250 feet.
In Subdistricts A, B and C, and Subareas D1, D2 and D3 of the Hell's Kitchen Subdistrict D, and Subdistrict E, the height and setback regulations set forth in paragraphs (a) through (d) of Section 93-42 (Height and Setback in Subdistricts A, B, C, D, E, F and G) shall apply, except that such regulations are modified in certain locations as set forth in this Section. Such modifications include the establishment of street wall location regulations, and minimum and maximum base heights, as shown on Map 3 (Mandatory Street Wall Requirements) of Appendix A of this Chapter. Such modifications also include depths of required setbacks, maximum length of building walls for towers, and tower lot coverage. Special provisions for recesses and sidewalk widenings are as follows:
- Recesses
Where street walls are required to be located on street lines or sidewalk widening lines, ground floor recesses up to three feet deep shall be permitted for access to building entrances, and deeper recesses shall be permitted only where necessary to comply with the pedestrian circulation space provisions of Section 93-63. Above a height of 60 feet for buildings fronting upon 34th Street in Subdistrict C or above a height of 50 feet for buildings fronting upon Tenth Avenue in Subdistricts C and D, and up to any specified minimum base height, recesses are permitted provided that the aggregate length of such recesses does not exceed 30 percent of the length of the required street wall at any level, and the depth of such recesses does not exceed five feet. No limitations on recesses shall apply above any specified minimum base height or to any portion of a zoning lot where street walls are not required.
Where street walls are required to extend along the entire street frontage of a zoning lot, no recesses shall be permitted within 20 feet of an adjacent building, or within 30 feet of the intersection of two street lines, except where corner articulation rules apply. - Sidewalk Widenings
Where a street wall is required to extend along the entire street frontage of a zoning lot, and such street is intersected by a street with a mandatory sidewalk widening, no street wall shall be required within such sidewalk widening. Where corner articulation rules apply, the inner boundary of any required sidewalk widening may be considered to be the street line. The mandatory street wall requirements are illustrated on Map 3 in Appendix A of this Chapter. Where sidewalk widening lines are specified, such lines shall be parallel to and five or 10 feet from the street line, as required pursuant to Section 93-61 and illustrated on Map 4 (Mandatory Sidewalk Widenings) in Appendix A.
In Subdistrict F, the provisions of Section 93-41 (Rooftop Regulations) and Section 93-56 (Special Height and Setback Regulations in Subdistrict F) shall apply.
In Subdistrict G, the provisions of Sections 93-57 (Special Height and Setback Regulations in Subdistrict G) and 93-58 (Special Permit for Modification of Height and Setback Regulations) shall apply.
The tower lot coverage requirements of paragraph (c) of Section 93-42 shall not apply within the Large-Scale Plan Subdistrict A.
- Hudson Boulevard
For the purposes of this paragraph (a), Hudson Boulevard shall be considered to be a wide street. The street wall of buildings shall be located on the Hudson Boulevard sidewalk widening line and extend along at least 70 percent of the length of the Hudson Boulevard frontage of the zoning lot, and shall rise without setback to a minimum base height of 90 feet and a maximum base height of 120 feet. On corner lots, the maximum base height may apply along intersecting narrow street lines for a distance of 100 feet from its intersection with Hudson Boulevard. Above a height of 120 feet, a setback at least 25 feet in depth is required from the Hudson Boulevard street line, and setbacks from intersecting narrow streets shall comply with the provisions of paragraph (b) of Section 93-42 (Height and Setback in Subdistricts A, B, C, D, E and F).
Alternatively, for zoning lots that occupy the entire Hudson Boulevard block front, the Hudson Boulevard street wall may rise above a height of 120 feet without setback at the Hudson Boulevard sidewalk widening line, provided that:- the aggregate width of such street wall facing Hudson Boulevard does not exceed 100 feet;
- all other portions of the building that exceed a height of 120 feet are set back at least 25 feet from the Hudson Boulevard street line at a height not lower than 90 feet; and
- all portions of the building that exceed a height of 120 feet are set back from a narrow street in compliance with the provisions of paragraph (b) of Section 93-42.
- Tenth Avenue
The street wall of buildings shall be located within 10 feet of the Tenth Avenue street line and extend along at least 70 percent of the Tenth Avenue frontage of the zoning lot, and shall rise without setback to a minimum base height of 90 feet and a maximum base height of 150 feet. On corner lots, the maximum base height may apply along intersecting narrow street lines for a distance of 100 feet from its intersection with Tenth Avenue. Above a height of 150 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply.
Alternatively, for zoning lots that occupy the entire Tenth Avenue block front and where no portion of the building is within 10 feet of the Tenth Avenue street line, the Tenth Avenue street wall may rise above a height of 150 feet without setback, provided:- the aggregate width of such street wall does not exceed 100 feet;
- all other portions of the building that exceed a height of 150 feet are set back at least 10 feet from the Tenth Avenue street wall of the building at a height not lower than 90 feet; and
- all portions of the building that exceed a height of 150 feet are set back from a narrow street in compliance with the provisions of paragraph (b) of Section 93-42.
- Midblocks
For all zoning lots with frontage along the northerly street lines of West 35th through West 40th Streets, the street wall of any building shall be located on and extend along at least 50 percent of the length of the sidewalk widening line of the zoning lot and shall rise without setback to a minimum base height of 60 feet and a maximum base height of 120 feet. Above a height of 120 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. Alternatively, the street wall of a building may rise without setback at the sidewalk widening line provided the aggregate width of such street wall does not exceed 100 feet or 50 percent of the width of such northerly street line frontage of the zoning lot, whichever is less, and provided all other portions of the building that exceed a height of 120 feet comply with the setback provisions of Section 93-42. The provisions of this paragraph shall not apply within 100 feet of Eleventh Avenue. However, any zoning lot partially within 100 feet of Eleventh Avenue may, as an alternative, apply the provisions of this paragraph (c) to the entire West 35th, West 36th, West 37th, West 38th, West 39th or West 40th Street street frontage of the zoning lot.
For all zoning lots with frontage along the southerly street lines of West 36th through West 41st Streets, the street wall of any building shall not exceed a maximum base height of 120 feet. Above a height of 120 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. - Rear setback
No yard requirements shall apply to any commercial building or commercial portion of a building. However, above a height of 120 feet, no portion of such building shall be nearer to a rear lot line than 20 feet.
- Hudson Boulevard
The provisions of paragraph (a) of Section 93-512 (Subareas A3, A4 and A5 of the Large-Scale Plan Subdistrict A) shall apply, except that the maximum base height shall be 150 feet. - West 34th Street
The street wall of any building shall be located on the West 34th Street sidewalk widening line and extend along at least 70 percent of the West 34th Street frontage of the zoning lot, and shall rise without setback to a minimum base height of 90 feet and a maximum base height of 150 feet. For portions of buildings exceeding a height of 150 feet, a setback of 20 feet from the street line of West 34th Street shall be required. However, a street wall may rise without setback along the sidewalk widening line provided the aggregate width of such street wall does not exceed 50 percent of the width of the West 34th Street frontage of the zoning lot and provided all other portions of the building that exceed a height of 150 feet are set back at least 20 feet from the street line of West 34th Street. - Tenth Avenue
The regulations set forth in paragraph (b) of Section 93-512 shall apply. - Rear setback
The provisions of paragraph (d) of Section 93-512 shall apply.
- Location of buildings
Buildings shall be located only in the following areas:- east of the southerly prolongaton of the eastern sidewalk widening line of Hudson Boulevard East;
- west of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West and within 220 feet of West 33rd Street;
- west of the southerly prolongation of the eastern sidewalk widening line of Hudson Boulevard East and within 220 feet of West 30th Street, provided that either:
- such area contains only uses in Use Groups 3 and 4; or
- where such area includes residential use, such residential use shall be located only in a building, or portion of a building, located west of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West, and such building may also include uses in Use Groups 3, 4, 6A and 6C. In addition, uses in Use Group 3 or 4 may be located in a building separate from any building containing residential use, provided that any such separate building may not be located closer than 50 feet east of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West.
- for any building located at or above the elevation of the High Line bed which faces the ERY High Line, the street wall shall not be located closer than five feet to the edge of the ERY High Line and such five foot separation shall remain unobstructed, from the level of the High Line bed adjacent to such building to the sky. Notwithstanding the foregoing, for any building located partly within 335 feet of the Tenth Avenue street line, any portion thereof of up to 280 feet in width, as measured parallel to West 30th Street, may be located above the High Line bed at a height of 60 feet or more measured from the High Line bed, provided such portion has a maximum width of 200 feet along the West 30th Street street line and a maximum average width of 240 feet. Structural columns and related architectural features placed within the maximum width of 200 feet along the West 30th Street street line supporting such portion of the building may be located within five feet of the southern edge of the ERY High Line, and such columns and related architectural features shall, when viewed in elevation along West 30th Street, occupy no more than 50 percent of the measured area of such elevation located within the maximum width of 200 feet along the West 30th Street street line, from the mean level of the adjoining public sidewalk to a height of 60 feet above the level of the High Line bed. A maximum of 30 percent of such measured area may be constructed of opaque materials. Additionally, such columns and related architectural features shall, when viewed in elevation along West 30th Street, occupy no more than 45 percent of the measured area of such elevation located within the maximum width of 200 feet along the West 30th Street street line, from the level of the High Line bed to a height of 25 feet above the level of the High Line bed.
- Height and setback
No setbacks shall be required for any building wall facing Eleventh Avenue, West 30th Street or West 33rd Street. Along Tenth Avenue, a street wall with a minimum height of 60 feet is required to extend along at least 70 percent of the Tenth Avenue frontage of the zoning lot not occupied by the public plaza required pursuant to Section 93-71. Such street wall shall align with any existing street wall facing Tenth Avenue. Existing street walls shall be treated in a manner that provides for visual articulation. - Length of building walls
The provisions of paragraph (d) of Section 93-42 limiting the length of building walls above a height of 500 feet shall not apply.
The tower lot coverage requirements of paragraph (c) of Section 93-42 shall not apply within the Farley Corridor Subdistrict B.
The provisions of this Section shall apply within an area bounded by Tenth Ave, West 31st Street, the Lincoln Tunnel Approach and West 33rd Street.
No building shall exceed a height of 150 feet within 10 feet of West 33rd Street, 15 feet of Tenth Avenue and 20 feet of West 31st Street, except as provided below:
- along West 31st Street, a building may rise without setback provided no part of such building is within 15 feet of West 31st Street; and
- along West 33rd Street, a building may rise without setback, provided that the aggregate width of street walls above a height of 150 feet and within 10 feet of the West 33rd Street street line does not exceed 50 percent of the length of the West 33rd Street frontage of the zoning lot.
However, if more than 75 percent of the total floor area existing on the zoning lot on January 19, 2005, is demolished, the reconstructed buildings shall not exceed a height of 150 feet within 15 feet of a wide street line and 20 feet of a narrow street line.
The provisions of this Section shall apply within the area bounded by Ninth Ave, West 31st Street, the Lincoln Tunnel Approach and West 33rd Street.
No building or other structure shall exceed a height of 150 feet within 15 feet of a wide street line and 20 feet of a narrow street line. However, on a narrow street, a building may rise without setback provided no part of such building is within 15 feet of the narrow street line.
No rear yard or rear yard equivalent regulations shall apply to any building developed or enlarged pursuant to this Section. Furthermore, the provisions of this Section may be waived or modified in conjunction with the granting of a special permit pursuant to Section 74-41 (Arenas, Auditoriums, Stadiums or Trade Expositions) for the development of an arena in the area bounded by Ninth Avenue, West 31st Street, Dyer Avenue and West 33rd Street.
Along Eighth Avenue, street walls shall be provided as follows:
- A street wall shall be provided for the mandatory public space required pursuant to paragraph (a) of Section 93-74. Such street wall shall extend for at least 100 feet along the Eighth Avenue sidewalk widening line and rise without setback to a minimum height of 60 feet. No portion of such street wall shall exceed a height of 150 feet within 15 feet of the Eighth Avenue street line. However, such street wall may encroach upon the mandatory sidewalk widening provided the height of such street wall within the sidewalk widening does not exceed 90 feet.
- In addition to the street wall required pursuant to paragraph (a) of this Section, street walls shall be provided along at least 35 percent of the Eighth Avenue frontage of the zoning lot. Such street walls shall be located within 10 feet of the Eighth Avenue street line and rise without setback to a minimum height of 90 feet and a maximum height of 150 feet, except that no setbacks shall be required where such street walls are located 10 feet from the Eighth Avenue street line.
- No street walls shall be located further than 10 feet from the Eighth Avenue street line unless they front upon a public plaza provided pursuant to paragraph (c) of Section 93-74. Along West 31st and West 33rd Streets, any portion of a street wall that exceeds a height of 150 feet shall be set back at least 15 feet from the West 31st and West 33rd Street street lines, as applicable. As an alternative, if the entire building is set back at least 10 feet from the West 31st or West 33rd Street street line, such building may rise without setback along such street.
- 34th Street
For zoning lots with frontage on 34th Street, the street wall of a building shall be located on and extend along the entire West 34th Street street line, except that to allow for corner articulation, the street wall may be located anywhere within an area bounded by intersecting street lines and lines 15 feet from and parallel to such street lines. Such street walls shall rise without setback to a minimum base height of 120 feet and a maximum base height of 150 feet. For corner lots, these provisions shall also apply along any intersecting street line for a minimum distance of 50 feet and a maximum distance of 100 feet from its intersection with West 34th Street. Above a height of 150 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. - Tenth Avenue
For zoning lots with frontage on Tenth Avenue, the provisions of paragraph (a) of Section 93-541 shall apply. - Midblocks between Eighth Avenue and Ninth Avenue
For zoning lots with frontage on West 33rd Street or West 35th Street beyond 100 feet of Eighth Avenue and Ninth Avenue, the street wall of any building shall be located on and extend along the entire West 33rd Street or West 35th Street frontage of the zoning lot not occupied by existing buildings to remain. Such street wall shall rise without setback to a minimum base height of 80 feet and a maximum base height of 90 feet. However, if the height of an adjacent street wall fronting on the same street line is higher than 90 feet before setback, the street wall of the new or enlarged building may rise without setback to the height of such adjacent street wall, up to a maximum height of 120 feet. Above a height of 90 feet or the height of the adjacent street wall if higher than 90 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. The street wall of any building may rise to a height less than 80 feet, except where such building is located on a zoning lot with multiple buildings, one or more of which is developed, enlarged or altered after February 2, 2011, to a height exceeding 80 feet.
- Tenth Avenue
- For zoning lots that do not occupy the entire Tenth Avenue block front, and for zoning lots that occupy the entire Tenth Avenue block front where existing buildings containing residences will remain, the street wall of any development or enlargement shall be located on and extend along the entire Tenth Avenue street line, except that to allow for corner articulation, the street wall may be located anywhere within an area bounded by intersecting street lines and lines 15 feet from and parallel to such lines. Such street wall shall rise without setback to a minimum base height of 90 feet and a maximum base height of 150 feet, except that such minimum base height requirement shall not apply to any existing buildings containing residences to remain. Where such zoning lots also front upon a narrow street, these provisions shall apply along such narrow street frontage for a minimum distance of 50 feet and a maximum distance of 100 feet from the intersection of Tenth Avenue. Above a height of 150 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply.
- For zoning lots that occupy the entire Tenth Avenue block front, and where no existing buildings fronting upon Tenth Avenue will remain, the street wall shall be located within 10 feet of the Tenth Avenue street line and extend along the entire Tenth Avenue frontage of the zoning lot and shall rise without setback to a minimum base height of 90 feet and a maximum base height of 150 feet. These provisions shall apply for a minimum distance of 50 feet and a maximum distance of 100 feet from the intersection of Tenth Avenue.
Above a height of 150 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. Alternatively, the Tenth Avenue street wall may rise above 150 feet without setback, provided that:- the aggregate width of such street wall does not exceed 100 feet;
- all other portions of the building that exceed a height of 150 feet are set back at least 10 feet from the Tenth Avenue street wall of the building at a height not lower than 90 feet;
- all portions of the building that exceed a height of 150 feet are set back from a narrow street in compliance with the provisions of paragraph (b) of Section 93-42; and
- all portions of the Tenth Avenue street wall that do not exceed a height of 90 feet are located 10 feet from the Tenth Avenue street line, except that recesses may be provided in accordance with the recess provisions of paragraph (a) of Section 93-50. Above a height of 90 feet, up to a height of 150 feet, any street wall facing Tenth Avenue shall be located no closer to Tenth Avenue than 10 feet.
- Hudson Boulevard
The regulations set forth in paragraph (a) of Section 93-512 (Subareas A3, A4 and A5 of the Large-Scale Plan Subdistrict A) shall apply, except that wherever a setback from the Hudson Boulevard street line is required to be at least 25 feet deep, such setback depth may be reduced to 15 feet. - Midblocks between Tenth Avenue and Hudson Boulevard
The regulations set forth in paragraph (c) of Section 93-512 shall apply. - Length of building wall
The maximum length of any story located above a height of 150 feet that faces north or south shall not exceed 100 feet. Such length shall be measured by inscribing within a rectangle the outermost walls at the level of each story entirely above a height of 150 feet. Any side of such rectangle from which perpendicular lines may be drawn to the nearest narrow street line shall not exceed 100 feet. - Tower lot coverage
Where more than one tower on a zoning lot contains residences, the minimum lot area requirement of paragraph (c)(1) of Section 93-42 shall not apply to the highest 80 feet of at least half of the number of such towers.
In Subareas D4 and D5 of Hell's Kitchen Subdistrict D, the underlying height and setback regulations shall apply, except that:
- the rooftop regulations set forth in Section 93-41 shall apply;
- within the C2-5 District of Subarea D4, commercial uses shall be limited to two stories or a height of 30 feet, whichever is less;
- within the C1-7A District of Subarea D5, recesses in the street wall of any building facing Ninth Avenue shall not be permitted within 20 feet of an adjacent building or within 30 feet of the intersection of two street lines, except as provided for permitted corner articulation; and
- the regulations set forth in paragraph (d) of Section 23-692 (Height limitations for narrow buildings or enlargements) shall be modified to allow portions of buildings with street walls less than 45 feet in width to reach the height of the tallest abutting building without regard to the width of the street onto which such building fronts.
For zoning lots that are wholly or partially within Hell's Kitchen Subdistrict D and provide publicly accessible open areas adjacent to or over the Lincoln Tunnel Approaches or Dyer Avenue, the City Planning Commission may authorize height and setback modifications within C2-5 Districts mapped within R8A Districts and the distribution of floor area without regard to district boundaries, provided the Commission finds that:
- such publicly accessible open area provides an appropriate amenity to the surrounding area;
- such publicly accessible open area has appropriate access, circulation, landscaping, seating, paving and lighting;
- modifications to the height and setback regulations of C2-5 Districts mapped within R8A Districts result in a building that does not exceed a height of 180 feet and is compatible with the scale and character of the surrounding area; and
- all necessary approvals have been granted by the Port Authority, or adequate provision has been made for the receipt of such approvals prior to the issuance of any building permit.
In granting such authorization, the Commission may prescribe additional conditions and safeguards to minimize adverse effects on the character of the surrounding area.
Publicly accessible open areas authorized by this Section shall be accessible to the public at all times, except where the Commission has authorized a nighttime closing pursuant to Section 37-727 (Hours of access). Furthermore, such open areas shall comply with the requirements for public plazas set forth in Sections 37-744 (Litter receptacles), 37-75 (Signs), 37-77 (Maintenance) and paragraph (a) of Section 37-78 (Compliance).
All plans for publicly accessible open areas, once authorized, shall be filed and duly recorded in the Borough Office of the City Register of the City of New York, indexed against the property in the form of a legal instrument providing notice of the certification of the publicly accessible open areas and setting further such provisions as necessary to ensure compliance with the requirements of this Section. Such filing and recording of the instrument, together with the grant of all necessary approvals by the Port Authority, shall be a precondition for the filing for or issuance of any building permit for any development or enlargement on the zoning lot. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
No temporary certificate of occupancy from the Department of Buildings may be issued for any portion of any development or enlargement subject to the provisions of this Section until the Chairperson of the Commission certifies to the Department of Buildings that the public access area is substantially complete and that the public access area is open to and useable by the public. No permanent certificate of occupancy from the Department of Buildings may be issued for any portion of such development or enlargement until the Chairperson of the Commission certifies to the Department of Buildings that the public access area is complete and that all public access requirements of this Section have been met in accordance with the plans for such public access area.
- Zoning lots with Eighth Avenue frontage
For zoning lots with frontage on Eighth Avenue, the street wall of a building shall be located on the Eighth Avenue sidewalk widening line and, where applicable, on the West 39th Street and West 40th Street street lines, and extend along the entire street frontage of the zoning lot. Such street walls shall rise without setback to a minimum height of 90 feet and a maximum height of 120 feet. The street wall of any building may rise to a height less than 90 feet, provided that no building on the zoning lot exceeds such height except where such building is located on a zoning lot with multiple buildings, one or more of which is developed, enlarged or altered after February 2, 2011, to a height exceeding 90 feet.
Above a height of 120 feet, no portion of a building or other structure shall penetrate a sky exposure plane that begins at a height of 120 feet above the Eighth Avenue sidewalk widening line and street lines of West 39th Street and West 40th Street, as applicable, and rises over the zoning lot at a slope of four feet of vertical distance for each foot of horizontal distance, except as provided below:- any portion of the building or other structure developed or enlarged pursuant to the tower regulations of Sections 33-45 or 35-64, as applicable, may penetrate the sky exposure plane;
- permitted obstructions, as listed in paragraph (a) of Section 93-41, may penetrate the sky exposure plane. In addition, a dormer, as listed in paragraph (c)(1) of Section 23-621, may penetrate the sky exposure plane.
- Zoning lots without Eighth Avenue frontage
For zoning lots without frontage on Eighth Avenue, the street wall of a building shall be located on the street line and extend along the entire street frontage of the zoning lot not occupied by existing buildings to remain. Such street walls shall rise without setback to a minimum base height of 80 feet and a maximum base height of 90 feet. However, if the height of an adjacent street wall fronting on the same street line is higher than 90 feet before setback, the street wall of the new or enlarged building may rise without setback to the height of such adjacent street wall, up to a maximum height of 120 feet. Above a height of 90 feet or the height of the adjacent street wall if higher than 90 feet, the setback provisions of paragraph (b) of Section 93-42 shall apply. The street wall of any building may rise to a height less than 80 feet, provided that no building on the zoning lot exceeds such height except where such building is located on a zoning lot with multiple buildings, one or more of which is developed, enlarged or altered after February 2, 2011, to a height exceeding 80 feet.
The height and setback regulations set forth in this Section, inclusive, shall apply to specific development sites identified as Sites 1 through 6 on Map 2 (Subdistrict F: Site Plan) in Appendix B. All buildings or other structures developed or enlarged within Subdistrict F, with the exception of those approved as part of a public access area pursuant to Section 93-78 (Site and Landscape Plans for Public Access Areas in Subdistrict F), shall occur within these designated site locations. However, portions of a building located entirely below grade, and exempt from the definition of floor area, shall be permitted to extend beyond such designated site locations. Furthermore, the boundary of Site 6 may be extended in a westerly direction, by up to 40 feet, to accommodate a public school in accordance with the provisions of paragraph (b) of Section 93-568 (Site 6).
Map 4 (Mandatory Sidewalk Widenings) in Appendix A identifies the location of a sidewalk widening required along Eleventh Avenue that is referenced in this Section, inclusive. Regulations governing the design of this sidewalk widening are set forth in Section 93-61.
Public access areas in Subdistrict F shall be comprised of publicly accessible open spaces, private streets and pedestrian ways. Map 3 (Subdistrict F: Public Access Area Plan) in Appendix B identifies the location of publicly accessible open spaces, private streets and pedestrian ways that are referenced in this Section.
Publicly accessible open spaces are comprised of the Western Open Space, the Central Open Space, the Southwest Open Space, the Northeast Plaza, the Midblock Connection and the High Line. General rules governing such publicly accessible open spaces are set forth in Section 93-75 (Publicly Accessible Open Spaces in Subdistrict F).
Publicly accessible private streets are comprised of the West 32nd Street Extension (including the Allee, as defined in paragraph (c)(2) of Section 93-761 and shown on Map 3 in Appendix B) and the West 31st Street Extension. Publicly accessible pedestrian ways are comprised of the West 30th Street Corridor, and the Connector. General rules governing such private streets and pedestrian ways are set forth in Section 93-76 (Publicly Accessible Private Streets and Pedestrian Ways in Subdistrict F).
For the purposes of applying height and setback regulations, the term "buildings" shall include buildings or other structures.
The following regulations shall apply to all buildings within Sites 1 through 6:
- Street wall location
For the purposes of applying the height and setback regulations of this Section, inclusive, wherever a building fronts upon any publicly accessible open space, private street or pedestrian way, as shown on Map 3 (Subdistrict F: Public Access Area Plan) in Appendix B, the boundary of such publicly accessible open spaces, private streets or pedestrian ways shall be considered to be a street line. Furthermore, for the purposes of applying such height and setback regulations, the sidewalk widening line required along Eleventh Avenue shall be considered the Eleventh Avenue street line.
Wherever a building on Sites 1, 5 or 6 faces the High Line, the street wall shall not be located closer than five feet to the edge of the High Line, as shown on Map 3. Such five foot separation shall remain unobstructed, from the level of finished grade adjacent to a building, to the sky, except as permitted:- for that portion of a building on Site 5 located above a height of 50 feet as measured from the High Line bed, pursuant to Section 93-567 (Site 5);
- for that portion of a building on Site 6 located below the High Line, pursuant to Section 93-568 (Site 6); and
- pursuant to paragraph (d) of Section 93-756 (General requirements for the High Line).
- Measurement of building heights
- Measurement of building base and transition heights
For portions of a building that front upon a publicly accessible sidewalk, the maximum building base height and, where applicable, the maximum transition height of a street wall, shall be measured from the mean level of the public sidewalk that such street wall fronts upon. For portions of a building that front upon publicly accessible open spaces in which no sidewalks are provided adjacent to a street wall, the maximum building base height or, where applicable, the maximum transition height of a street wall, shall be measured from the mean level of the final grade of the open space that such street wall fronts upon. However, the following street wall heights shall be measured from the High Line bed:- on Site 6, the portion of a street wall above the High Line bed facing the High Line beyond 60 feet of Eleventh Avenue; and
- on Site 6, along the Southwest Open Space within 60 feet of the High Line.
- Measurement of tower heights
The height of a tower shall be measured from the highest level of the public sidewalk or finished grade located nearest such tower, to the ceiling of the highest story of the tower where floor area occupies more than 75 percent of the gross area of such story. However, on Site 5, the height of the tower shall be measured from the High Line bed.
Where minimum height differences are required between towers, such heights, for each tower, shall be measured from the Manhattan Datum, which is 2.75 feet above sea level.
- Towers
Criteria for towers on Sites 1 through 6 are set forth in this Section, inclusive. The minimum distance between all such towers shall be 60 feet.
The locations of all street walls identified in this Section are shown on Map 5 (Subdistrict F: Mandatory Street Wall Requirements) in Appendix B.
- Applicability
The provisions of this Section shall apply to:- All street walls of buildings on Site 1 that front along:
- the West 32nd Street Extension;
- the Western Open Space within 60 feet of the West 32nd Street Extension; and
- the Midblock Connection within 60 feet of the West 32nd Street Extension.
- All street walls of buildings on Site 2 that front along:
- Eleventh Avenue south of the Northeast Plaza;
- the West 32nd Street Extension; and
- the Midblock Connection within 60 feet of the West 32nd Street Extension.
- All street walls of a building on Site 4 that front along:
- Eleventh Avenue;
- the West 32nd Street Extension within 50 feet of Eleventh Avenue; and
- the West 31st Street Extension within 50 feet of Eleventh Avenue.
- All street walls of a building on Site 6 that front along:
- Eleventh Avenue five feet north of the High Line;
- the West 31st Street Extension;
- the High Line, completely above the High Line bed;
- the Southwest Open Space within 60 feet of the High Line; and
- the Southwest Open Space within 60 feet of the West 31st Street Extension.
- Street wall location
All street walls identified in paragraph (a) of this Section shall be located on the street line.
All such street walls shall extend along the entire street frontage of the site or the required portion identified in paragraph (a). However, such street wall location rules may be modified in accordance with the recess provisions of paragraph (c) of this Section. - Recesses
- Ground floor recesses up to three feet deep shall be permitted for access to building entrances;
- To allow for corner articulation, the required street wall may be located anywhere within an area bounded by intersecting street lines and lines 15 feet from and parallel to such lines;
- To ensure variation in the required street wall, a building shall provide recesses or ground floor level setbacks in accordance with the following provisions:
- A minimum of 20 percent of the aggregate width of street walls shall provide a minimum recess of three feet from the street wall above the level of the second story. However, for the portion of Site 6 that fronts along the High Line, such recess shall be provided above the level of the first story. However, no portion of such recess shall be located within 30 feet of the intersection of two street lines, except where corner articulation is provided in accordance with paragraph (c)(2) of this Section.
- A maximum of 30 percent, or 50 percent for Site 4, of the aggregate width of street walls may provide a recess of up to 15 feet at any level, which may extend to the height of the building base and may allow for portions of towers to rise without setback from the ground floor level. However, no such setbacks shall be permitted within 30 feet of the intersection of two street lines, except where corner articulation is provided in accordance with paragraph (c)(2) of this Section.
In addition to the applicable requirements set forth in Section 93-562 (Street wall regulations for certain streets), the provisions of this Section shall apply to buildings on Site 1.
- Building base
- Facing West 33rd Street
The street wall of the building facing West 33rd Street may rise without setback to a maximum base height of 120 feet before a setback is required. However, no setbacks shall be required within 150 feet of Twelfth Avenue. - Facing the West 32nd Street Extension
The provisions of this paragraph, (a)(2), shall apply to street walls facing the West 32nd Street Extension, the Western Open Space and the Midblock Connection within 60 feet of the West 32nd Street Extension. Such street walls shall rise without setback to a minimum base height of 60 feet and a maximum base height of 90 feet. - Facing the Western Open Space
The provisions of this paragraph, (a)(3), shall apply to street walls facing the Western Open Space beyond 60 feet of its intersection with the West 32nd Street Extension. The street wall of the building may rise without setback to a maximum base height of 90 feet before a setback is required. However, no setbacks shall be required within 150 feet of Twelfth Avenue.
- Facing West 33rd Street
- Transition height
All portions of a building that exceed the applicable maximum base height specified in paragraph (a) of this Section shall be set back in accordance with the provisions of this paragraph (b), except that where towers are provided directly above a portion of the transition height, such a portion of transition height located directly below a tower shall provide setbacks in accordance with the tower provisions of paragraph (c) of this Section.
Portions of a transition height facing West 33rd Street shall be set back from the West 33rd Street street line a minimum of 20 feet. Portions of a transition height facing the Western Open Space that exceed the maximum base height shall be set back from the street wall of a building facing the Western Open Space a minimum of 30 feet. However, in both cases, no such setback shall be required within 150 feet of Twelfth Avenue.
Above the maximum base height, a street wall may rise to a maximum transition height equal to one-half the height of the street wall of the building base facing the Western Open Space. Such a transition height shall not exceed a maximum height of 135 feet.
All portions of a building that exceed the maximum transition height shall comply with the tower provisions of paragraph (c) of this Section. - Towers
All stories of a building located partially or wholly above the maximum transition height shall be considered a "tower" and shall comply with the provisions of this paragraph (c).
- Required setbacks
All towers, or portions of a transition height located beneath a tower, shall be set back at least 15 feet from the street line of West 33rd Street and from the street walls of the building facing the West 32nd Street Extension, except that the depth of such setback distance may include the depth of any permitted recesses. However, no setbacks shall be required within 150 feet of Twelfth Avenue, along the Western Open Space or along the Midblock Connection to allow portions of towers that comply with the provisions of paragraphs (c)(2) and (c)(3) of this Section to rise without setback. - Maximum floor plate
If more than one tower is provided on Site 1, the aggregate gross area of any such tower stories, measured at any height, shall not exceed 25,000 square feet. - Maximum length and height
The outermost walls of all stories of a tower, when viewed from above, shall be inscribed within a rectangle where the east-west dimension shall not exceed a length of 110 feet and the north-south dimension shall not exceed a length of 160 feet. Where more than one tower is located on Site 1, each tower shall comply independently with such maximum dimensions.
If more than one tower is located on Site 1, the height of the easternmost tower shall be a minimum of 100 feet greater than the height of the westernmost tower.
All towers that exceed a height of 350 feet shall provide articulation in accordance with Section 93-569 (Tower top articulation).
In addition to the applicable requirements set forth in Section 93-562 (Street wall regulations for certain streets), the provisions of this Section shall apply to buildings on Site 2.
- Building base
- Facing Eleventh Avenue
The provisions of this paragraph (a)(1) shall apply to street walls facing Eleventh Avenue (exclusive of street walls facing the Northeast Plaza, which need not set back), and the West 32nd Street Extension within 60 feet of Eleventh Avenue. Such street walls shall rise without setback to a minimum height of 120 feet and a maximum height of 150 feet. Above a height of 150 feet, all portions of such building shall be set back from the street wall of the building at least 15 feet, except such setback distance may include the depth of any permitted recesses. These building base provisions may apply along the West 32nd Street Extension street line beyond 60 feet of Eleventh Avenue, up to a maximum distance of 100 feet from Eleventh Avenue. - Facing the West 32nd Street Extension
The provisions of this paragraph (a)(2) shall apply to street walls facing the West 32nd Street Extension beyond 60 feet of Eleventh Avenue (or beyond 100 feet if the optional building base provisions of paragraph (a)(1) of this Section are applied along the West 32nd Street Extension), and the Midblock Connection within 60 feet of the West 32nd Street Extension. Such street walls shall rise without setback to a minimum height of 90 feet and a maximum height of 120 feet. Above a height of 120 feet, all portions of such buildings facing the West 32nd Street Extension shall be set back from the street wall of the building at least 15 feet, except such setback distance may include the depth of any permitted recesses. Portions of street walls along the Midblock Connection within 60 feet of the West 32nd Street Extension need not set back above the maximum base height to allow tower portions that comply with the provisions of paragraph (b) of this Section to rise without setback. - Facing West 33rd Street
Street walls facing West 33rd Street (exclusive of the Northeast Plaza) may rise without setback to a maximum base height of 150 feet. Above a height of 150 feet, setbacks shall be required as follows:- portions of a building facing West 33rd Street within 150 feet of the Eleventh Avenue street line shall provide a 15 foot setback from the street line of West 33rd Street;
- portions of a building beyond 150 feet of Eleventh Avenue that do not exceed an aggregate width of street wall of 150 feet, as measured along the West 33rd Street street line, shall be permitted to rise without setback; and
- portions of a building located beyond 150 feet of Eleventh Avenue that exceed the aggregate width of street wall of 150 feet, as measured along the West 33rd Street street line, shall be set back a minimum of 15 feet from the street line of West 33rd Street.All portions of a building that exceed a height of 150 feet shall comply with the tower provisions of paragraph (b) of this Section.
- Facing Eleventh Avenue
- Towers
All stories of a building located partially or wholly above a height of 150 feet shall be considered a tower and shall comply with the provisions of this paragraph, (b). Not more than one tower shall be allowed on Site 2.
- Maximum floor plate
The gross area of any tower story shall not exceed 40,000 square feet. - Maximum length and height
The outermost walls of all stories of a tower, when viewed from above, shall be inscribed within a rectangle where the east-west dimension shall not exceed a length of 250 feet.
All towers that exceed a height of 350 feet shall provide articulation in accordance with Section 93-569 (Tower top articulation).
The regulations of this Section shall apply to all buildings within Site 3.
All stories of a building located wholly or partially above the highest level of the adjoining public sidewalk or finished grade on Site 3 shall be considered a tower and shall comply with the provisions of this Section. Not more than one tower shall be permitted on Site 3.
- Ground floor
A maximum of 6,000 square feet of the ground floor shall be permitted to provide residential uses. The remaining portion of the ground floor shall provide an area that is accessible to the surrounding publicly accessible open spaces listed in Section 93-75 (Publicly Accessible Open Spaces in Subdistrict F). Such space may provide ground floor uses pursuant to Section 93-14 (Ground Floor Level Requirements), or may be considered part of the Central Open Space and comply with the regulations set forth in Section 93-75.
If such remaining ground floor level space provides ground floor uses pursuant to the requirements of paragraph (b)(2) of Section 93-14, such uses shall adjoin a minimum of 70 percent of the perimeter of the outermost walls of the ground floor of the building to a minimum depth of 30 feet. In addition, such outermost wall shall be at least 70 percent glazed with transparent material to a height of 40 feet.
If such remaining ground floor level space is considered part of the Central Open Space, such space may be open or enclosed. An open space provided pursuant to this paragraph (a) shall have a clear height of at least 40 feet measured from the level of an adjoining finished grade or sidewalk. An enclosed publicly accessible space provided pursuant to this paragraph (a) shall adjoin a minimum of 70 percent of the perimeter of the outermost walls of the ground floor of the building to a minimum depth of 30 feet. In addition, such outermost wall shall be at least 70 percent glazed with transparent material to a height of 40 feet. - Maximum floor plate
The gross area of any story of a tower on Site 3 shall not exceed 12,000 square feet. - Maximum length and height
The maximum horizontal dimension of a tower, measured in any direction, shall not exceed 145 feet. However, if the angle of the tower's maximum horizontal dimension is aligned within 15 degrees of a 45 degree line constructed from either the southwest or northeast corner of the Site 3 rectangle in plan, as shown on Map 2 (Subdistrict F: Site Plan) in Appendix B, then such maximum horizontal dimension measured in this direction may be increased to 160 feet, provided that the maximum dimension measured perpendicular to such increased dimension does not exceed a length of 120 feet.
The maximum height of a tower within Site 3 shall be a minimum of 100 feet taller than the tower height of Site 5.
All towers that exceed a height of 350 feet shall provide articulation in accordance with Section 93-569 (Tower top articulation).
In addition to the applicable requirements set forth in Section 93-562 (Street wall regulations for certain streets), the provisions of this Section shall apply to buildings on Site 4.
- Street wall location along West 31st and West 32nd Street Extensions
Any portion of a street wall facing the West 32nd Street Extension within 100 feet of Eleventh Avenue shall be set back at least 15 feet from the West 32nd Street Extension street line, which shall coincide with the northern edge of the Site 4 boundary. Any portion of a street wall facing the West 32nd Street Extension that extends beyond 100 feet of Eleventh Avenue, as measured along the West 32nd Street Extension street line, shall be set back at least 30 feet from the West 32nd Street Extension street line. Any portion of a street wall facing the West 31st Street Extension that extends beyond 100 feet of Eleventh Avenue, as measured along the West 31st Street Extension street line, shall be set back at least 15 feet from the West 31st Street Extension street line. - Building base facing Eleventh Avenue
The provisions of this paragraph (b) shall apply to street walls below a height of 120 feet facing Eleventh Avenue and the West 31st and West 32nd Street Extensions within 50 feet of Eleventh Avenue. Such street walls shall rise without setback to a minimum height of 90 feet and a maximum height of 120 feet. Above a height of 120 feet, all portions of a building facing Eleventh Avenue shall be set back from the street wall of the building at least 15 feet, except such setback distance may include the depth of any permitted recesses. Portions of street walls along the West 31st and West 32nd Street Extensions within 50 feet of Eleventh Avenue need not set back above the maximum base height to allow tower portions that comply with the provisions of paragraph (c) of this Section to rise without setback.
All portions of a building that exceed the maximum base height of 120 feet shall comply with the tower provisions of paragraph (c) of this Section. - Towers
All stories of a building located partially or wholly above the maximum base height of 120 feet shall be considered a tower and shall comply with the provisions of this paragraph (c). Not more than one tower shall be permitted on Site 4.
- Maximum floor plate
The gross area of any such story shall not exceed 12,000 square feet. - Maximum length and height
For any portion of a tower above 120 feet, the maximum horizontal dimension, measured in any direction, shall not exceed 145 feet. However, if the angle of the tower's maximum horizontal dimension is aligned within 15 degrees of a 45 degree line constructed from either the southwest or northeast corner of the Site 4 rectangle, in plan, as shown on Map 2 (Subdistrict F: Site Plan) in Appendix B, then such maximum horizontal dimension measured in this direction may be increased to 160 feet, provided that the maximum dimension measured perpendicular to such increased dimension does not exceed a length of 120 feet.
The maximum height of a tower on Site 4 shall be a minimum of 100 feet taller than any tower located on Site 3.
All towers that exceed a height of 350 feet shall provide articulation in accordance with Section 93-569 (Tower top articulation).
All stories of a building located wholly or partially above finished grade on Site 5 shall be considered a tower and shall comply with the provisions of this Section.
On Site 5, a building may be located adjacent to and above the High Line, provided no portion of such building or an associated structural column is located within five feet of the edge of the High Line from the level of finished grade to a level of 50 feet above the level of the High Line bed, as shown on Map 3 (Subdistrict F: Public Access Area Plan) in Appendix B.
- Maximum floor plate
The gross area of any story within that portion of a building or other structure located east of the High Line and wholly or partially above the finished grade to a height of 50 feet above the High Line bed shall not exceed 5,000 square feet.
The aggregate gross area of any portion of a building or other structure located west of the High Line and wholly or partially above the finished grade to a height of 50 feet above the High Line bed shall not exceed 700 square feet, and the maximum aggregate horizontal dimension of such portions, individually measured in their longest dimension, shall not exceed 30 feet.
The gross area of any story within that portion of a tower located above a height of 50 feet above the High Line bed shall not exceed 12,000 square feet. - Maximum length and height
At or below a height of 50 feet above the High Line bed, if a building is located so that it has portions on both sides of the High Line, the minimum horizontal dimension, measured in any direction between such portions shall be 60 feet.
For that portion of a tower located above a height of 50 feet above the High Line bed, the maximum horizontal dimension, measured in any direction, shall not exceed 145 feet. However, if the angle of the tower's maximum horizontal dimension is aligned within 15 degrees of a 45 degree line constructed from either the southwest or northeast corner of the Site 5 rectangle, in plan, as shown on Map 2 (Subdistrict F: Site Plan) in Appendix B, then such maximum horizontal dimension measured in this direction may be increased to 160 feet, provided that the maximum dimension measured perpendicular to such increased dimension does not exceed a length of 120 feet. Furthermore, the maximum horizontal dimension for that portion of a tower that spans the High Line, measured in any direction, shall not exceed 120 feet.
The maximum height of a tower on Site 5 shall be 350 feet.
In addition to the applicable requirements set forth in Section 93-562 (Street wall regulations for certain streets), the provisions of this Section shall apply to buildings on Site 6.
- Height and setback regulations
- Street wall beneath the High Line
The provisions of this paragraph (a) shall apply to street walls on Site 6 beneath the High Line that face West 30th Street, Eleventh Avenue and the Southwest Open Space.
All such street walls shall extend along the entire street frontage of the site, except that along West 30th Street, the street wall shall be no closer to the northerly street line of West 30th Street than the northerly edge of the southern row of structural columns of the High Line, and along the Southwest Open Space and Eleventh Avenue, the street wall shall extend to a point five feet north of the High Line. Ground floor recesses up to three feet deep shall be permitted for access to building entrances.
All such street walls shall rise without setback to a maximum height of the underside of the High Line bed. - Building base
- Facing Eleventh Avenue and the West 31st Street Extension, north of the High Line
The provisions of this paragraph (a)(2)(i) shall apply north of the High Line to street walls facing Eleventh Avenue, the West 31st Street Extension, portions of street walls facing the High Line within 60 feet of Eleventh Avenue, and portions of street walls facing the Southwest Open Space within 60 feet of the West 31st Street Extension. Such street walls shall rise without setback to a minimum height of 60 feet and a maximum height of 90 feet. Above a height of 90 feet, all portions of a tower, or portions of a transition height located beneath a tower facing Eleventh Avenue, the High Line and the West 31st Street Extension, shall be set back from the street wall of the building at least 15 feet, except such setback distance may include the depth of any permitted recesses. Portions of street walls along the Southwest Open Space within 60 feet of the West 31st Street Extension need not set back above the maximum base height to allow portions of towers, or portions of a transition height located beneath a tower that comply with the provisions of paragraphs (a)(3) and (a)(4) of this Section, respectively, to rise without setback. These building base provisions may apply along the High Line beyond 60 feet of Eleventh Avenue, up to a maximum distance of 100 feet from Eleventh Avenue. - Facing West 30th Street, north of the High Line
The provisions of this paragraph (a)(2)(ii) shall apply to street walls above the High Line bed, facing the High Line beyond 60 feet of Eleventh Avenue, and to those portions of street walls facing the Southwest Open Space that are within 60 feet of the High Line. Such street walls shall rise without setback to a minimum height of 50 feet as measured above the level of the High Line bed, and a maximum height of 60 feet as measured above the level of the High Line bed. Above a height of 60 feet, all portions of a tower, or portions of a transition height located beneath a tower facing the High Line, shall be set back from the street wall of the building at least 15 feet, except such setback distance may include the depth of any permitted recesses. Portions of street walls along the Southwest Open Space within 60 feet of the High Line need not set back above the maximum base height to allow portions of a tower, or portions of a transition height located beneath a tower that comply with the provisions of paragraphs (a)(3) and (a)(4), respectively, to rise without setback.All portions of a building that exceed the maximum base height of 90 feet shall comply with the tower provisions of paragraph (a)(4), with the exception of a building which provides a transition height in accordance with the provisions of paragraph (a)(3).
- Facing Eleventh Avenue and the West 31st Street Extension, north of the High Line
- Transition height
If the outermost walls of all stories of any tower provided in accordance with the tower provisions of paragraph (a)(4) are individually inscribed within a rectangle where the east-west dimension does not exceed a length of 110 feet, a transition height may be provided above the building base in accordance with the provisions of this paragraph (a)(3).
Above the maximum base height, a street wall may rise to a maximum transition height equal to two-thirds of the height of the street wall of the building base facing the West 31st Street Extension. Such a transition height shall not exceed a maximum height of 150 feet, as measured above the West 31st Street Extension street line.
All portions of a transition height shall be set back 30 feet from the street wall of the building base along the West 31st Street Extension and the High Line, except that where towers are provided directly above a portion of the transition height, such a portion of transition height located directly below a tower shall provide setbacks in accordance with the building base provisions of paragraph (a)(2) of this Section.
All portions of a building that exceed the maximum transition height shall comply with the tower provisions of paragraph (a)(4). - Towers
All stories of a building located partially or wholly above a height of 90 feet, or 150 feet if a transition height is provided in accordance with the provisions of paragraph (a)(3), shall be considered a tower and shall comply with the provisions of this paragraph (a)(4).- Maximum floorplate
If more than one tower is provided on Site 6, the aggregate gross area of any such tower stories, measured at any height, shall not exceed 25,000 square feet. - Maximum length and height
The outermost walls of all stories of a tower, when viewed from above, shall be inscribed within a rectangle where the east-west dimension shall not exceed a length of 160 feet and the north-south dimension shall not exceed a length of 110 feet. Where more than one tower is located on Site 6, each tower shall comply independently with such maximum dimensions.The aggregate width of street walls of all stories of a tower facing the West 31st Street Extension or the High Line shall not exceed 220 feet within 40 feet of the street wall of the building base.If more than one tower is provided on Site 6, such towers shall either be equal in height, or the easternmost tower shall have a height greater than the height of the westernmost tower.All towers that exceed a height of 350 feet shall provide articulation in accordance with Section 93-569 (Tower top articulation).
- Maximum floorplate
- Street wall beneath the High Line
- Certification to expand Site 6
The area of Site 6, as shown on Map 2 (Subdistrict F: Site Plan) in Appendix B, may be extended westward by up to 40 feet in order to accommodate a public school upon certification of the Chairperson of the City Planning Commission, that:- the Chairperson is in receipt of a letter from the School Construction Authority that describes the need for the additional area;
- the site and landscape plans for the Southwest Open Space have been approved by the Chairperson, pursuant to Section 93-78 (Site and Landscape Plans for Public Access Areas in Subdistrict F);
- no portion of a tower located on Site 6 extends beyond 395 feet west of the Eleventh Avenue street line; and
- any portion of a building located beyond 395 feet from the Eleventh Avenue street line shall affect southwesterly view corridors from the Central Open Space towards the Hudson River to the minimum extent necessary to accommodate a public school.
All towers that exceed a height of 350 feet shall provide articulation in accordance with this Section.
For the purposes of this Section, a minimum of the uppermost 15 percent of the height of a building or other structure, including all rooftop mechanical structures and their required enclosures pursuant to the regulations of paragraph (b) of Section 93-41 (Rooftop Regulations), shall henceforth be referred to as the "Tower Top Zone". However, chimneys, antennae or decorative spires shall not be considered part of the Tower Top Zone, provided no such structures contain floor area.
The height of such building or other structure shall be measured from the highest level of the public sidewalk or finished grade located nearest such building or other structure.
The Tower Top Zone shall contain an "Upper Zone" and a "Lower Zone." The Lower Zone shall be a minimum of 50 percent of the height of the Tower Top Zone and shall contain tower stories. The Upper Zone shall contain the highest tower story where floor area occupies more than 75 percent of the gross area of such story, and any enclosed rooftop mechanical equipment.
For the purposes of this Section, each tower of a building or other structure shall be comprised of four separate tower top elevation views that shall be used to measure compliance with the regulations of this Section. Each elevation view shall have an angle of 90 degrees from another such view.
Each tower top shall provide the following forms of articulation:
- Change in the building or other structure profile
- Constructing the profile change boundary
To comply with the provisions of this paragraph (a)(1), a rectilinear boundary within the Tower Top Zone shall be created in each elevation view to determine the required amount of profile change. In order to construct such boundary, two datum lines shall first be drawn in each elevation view. Such datum lines shall begin at the average outermost edges of those portions of tower floor plates above a height of 350 feet containing floor area below the Tower Top Zone, and shall extend upward for the entirety of the height of the building or other structure. The rectilinear profile change boundary shall include the portion of these two datum lines within the Tower Top Zone, as well as their intersection with two datum lines indicating the uppermost elevation and the lowermost elevation of the Tower Top Zone. In addition, a datum line shall indicate the boundary between the Upper and Lower Zone, creating a boundary for both the Upper Zone and Lower Zone. - Required profile change
A minimum of 10 percent of the area of the profile change boundary within the Lower Zone shall remain open to the sky in each required elevation view. Such profile change shall begin upward at the lowermost datum line of the Tower Top Zone. In addition, a minimum of 20 percent of the area of the profile change boundary within the Upper Zone shall remain open to the sky in each required elevation view.
However, for portions of a building or other structure providing enclosed rooftop mechanical equipment within the Upper Zone, the width (as viewed in elevation) of the lowermost portion of enclosed rooftop mechanical space at that point in elevation which coincides with the uppermost portion of the highest tower story shall in no event be reduced beyond 50 percent of the width of such highest tower story. Upwards of such a point in elevation, no restriction on maximum width reduction for enclosed rooftop mechanical spaces shall apply.
- Constructing the profile change boundary
- Change in the building or other structure lot coverage
For portions of a building or other structure within the Lower Zone, the average lot coverage for all tower stories within such zone shall not exceed 80 percent of the lot coverage of the tower story with the largest lot coverage below the Tower Top Zone and above a height of 350 feet. - Material continuity
A minimum of 10 percent of the surface area of the exterior portion of the facade of the building or other structure within the Tower Top Zone, as viewed in elevation, shall be composed of a single material. Such material shall be continuously visible (in each elevation view) from the lowermost datum line of the Tower Top Zone to the uppermost datum line of the Tower Top Zone. However, within each story of the Lower Zone, a break in the vertical continuity of the material shall be permitted, provided that the vertical break does not exceed 12 inches.
- Required setbacks
The required minimum setback for portions of buildings or other structures that exceed the maximum base height specified in paragraph (a) of Section 93-42 shall be 10 feet from a wide street and 15 feet from a narrow street. However, the required minimum setback along West 39th Street shall be five feet. - Tower lot coverage
The portion of any building or buildings located above a height of 150 feet shall be considered a "tower."- Towers shall occupy a minimum of 20 percent of the lot area of the zoning lot, except that this requirement shall not apply to the highest 40 feet of such tower or towers.
- Towers containing residences shall occupy a maximum of 40 percent of the lot area.
- The aggregate lot area of all towers, including residential and non-residential towers, shall not exceed 65 percent of the lot area.
Within the Special Hudson Yards District, except within C1-7A Districts, or C2-5 Districts mapped within R8A Districts, for developments or enlargements on zoning lots with at least 20,000 square feet of lot area or developments or enlargements on any size zoning lot that occupy the entire block front along a wide street, the City Planning Commission may modify the regulations set forth in Sections 93-40 (HEIGHT AND SETBACK REGULATIONS), inclusive, and 93-50 (SPECIAL HEIGHT AND SETBACK REGULATIONS), inclusive, provided the Commission finds that:
- such modifications will result in a better distribution of bulk on the zoning lot and will not adversely affect access to light and air for surrounding public access areas, streets and properties;
- where the development or enlargement is subject to the requirements of Sections 93-60 (MANDATORY IMPROVEMENTS), inclusive, or 93-70 (PUBLIC ACCESS REQUIREMENTS FOR SPECIAL SITES), inclusive, such modifications will not impair the quality of such public access areas on the zoning lot;
- such modifications are consistent with the goal of the special district to provide flexibility of architectural design and encourage more attractive building forms; and
- such modifications will result in a development or enlargement that enhances the streetscape and will be compatible with development in the surrounding area.
The Commission may prescribe additional conditions and safeguards to minimize adverse effects of the development or enlargement on the character of the surrounding area.
No rear yard equivalent shall be required in Subdistrict G.
Map 4 (Mandatory Sidewalk Widenings) in Appendix A of this Chapter specifies locations of mandatory sidewalk widenings. The depth of such sidewalk widenings shall be as indicated on Map 4 in Appendix A and shall be measured perpendicular to the street line. All sidewalk widenings shall be improved as sidewalks to Department of Transportation standards, at the same level as the adjoining public sidewalks, and shall be accessible to the public at all times.
In addition to the applicable underlying street tree planting requirements, in the Four Corners Subarea A2 of the Large-Scale Plan Subdistrict A, trees shall also be provided along the street edge of the mandatory sidewalk widenings along West 34th Street. All such trees shall be provided for the entire length of the street frontage of the zoning lot, at maximum intervals of 25 feet. Trees shall be planted in gratings flush to grade in at least 200 cubic feet of soil per tree with a depth of soil at least three feet, six inches. Species shall be selected and installed in accordance with specifications established by the Department of Parks and Recreation. The provisions of this Section shall not apply where the Department of Parks and Recreation determines that such tree planting would be infeasible.
In C2-8 and C6-4 Districts, except within Subdistrict G, all developments or enlargements on zoning lots of 5,000 square feet or larger with more than 70,000 square feet of new floor area shall provide pedestrian circulation space in accordance with the provisions of Section 37-50. In addition, for developments or enlargements that provide subway entranceways constructed after December 21, 2005, one and one-half times the area of such entranceway accessible to the public at street level may qualify as pedestrian circulation space, up to a maximum amount of 3,000 square feet.
Pedestrian circulation space shall not be required if any of the following conditions exist:
- The zoning lot is entirely occupied by a building of no more than one story in height.
- The zoning lot is an interior lot fronting on a wide street with less than 80 feet of street frontage.
- The zoning lot is a through lot and both street frontages are less than 25 feet in length.
- The zoning lot is required to provide public access pursuant to Section 93-70 (PUBLIC ACCESS REQUIREMENTS FOR SPECIAL SITES).
Any development or enlargement with a commercial floor area ratio of 5.0 or greater and located on a zoning lot with frontage upon Hudson Boulevard shall provide a major entranceway to the commercial portion of the building on Hudson Boulevard.
Any development or enlargement containing residences located on zoning lots with frontage upon Tenth Avenue north of West 33rd Street shall provide a major entrance to the residential portion of the building on or within 100 feet of Tenth Avenue.
The street wall of any building facing east towards Ninth Avenue south of West 33rd Street shall contain either a major building entrance or have at least 70 percent of its ground floor frontage occupied by retail uses.
- Any development or enlargement on a zoning lot that includes the southwest corner of West 40th Street and Eighth Avenue shall provide an easement for public access to the subway mezzanine or station as illustrated on Map 5 (Transit Facilities) in Appendix A of this Chapter. The easement shall accommodate a relocated subway entrance from the adjoining sidewalk to a location within the development or enlargement.
The Chairperson of the City Planning Commission shall certify that a plan has been submitted indicating the volume of the easement necessary for future construction of a subway entrance. Such plan shall be developed in consultation with, and with the approval of, the Transit Authority. The Chairperson may alternately certify that a plan has been submitted whereby the applicant agrees to provide the required easement, at the applicant's expense, within two years of request by the Transit Authority or by its designee.
An instrument establishing such transit easement, or agreement to provide one within two years of request by the Transit Authority, once certified, shall be filed and duly recorded in the Borough Office of the City Register of the City of New York, indexed against the property in the form of a legal instrument providing notice of such certification. Such filing and recording of the instrument shall be a precondition for the filing for or issuance of any building permit for any development or enlargement on the zoning lot. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
Floor space within any required transit easement shall be excluded from the definition of floor area, and may be temporarily used by the owner of the zoning lot for any permitted uses until such time as required by the Transit Authority or by its designee for subway purposes. Improvements or construction of a temporary nature within the easement volume for such temporary uses shall be removed by the owner of the zoning lot prior to the time at which public use of the easement area is required. A minimum notice of six months in writing shall be given by the Transit Authority to the owner of the zoning lot in order to vacate the tenants of such temporary uses. - For the locations listed in this paragraph, (b), floor space devoted to subway-related uses consisting of ventilation facilities and other facilities or services used or required in connection with the operation of a subway line or station, which are established pursuant to an easement or other agreement, shall be excluded from the definition of floor area in Section 12-10:.
- The volume bounded by Eleventh Avenue, a line 52 feet north of and parallel to West 33rd Street, the western boundary of the public park, and West 33rd Street, up to a height of 82 feet, as illustrated on Map 5.
- The volume bounded by Eleventh Avenue, West 36th Street, a line 95 feet east of and parallel to Eleventh Avenue, and a line 95 feet south of and parallel to West 36th Street, up to a height of 129 feet, as illustrated on Map 5.
- The tax lot located at Block 1051, Lot 2, existing on October 27, 2010, up to a height of 73 feet, as illustrated on the District Map in Appendix A of the Special Clinton District.
- The volume bounded by a line 37 feet east of and parallel to Eleventh Avenue, West 26th Street, a line 100 feet east of and parallel to Eleventh Avenue, and a line 95 feet south of and parallel to West 26th Street, up to a height of 60 feet, as illustrated on the District Map in Appendix A of the Special West Chelsea District.
Any transit easement or other agreement for such subway-related use shall be filed and duly recorded in the Borough Office of the City Register of the City of New York, and indexed against the property.
In Subareas A2 through A5 of the Large-Scale Plan Subdistrict A, the provisions of this Section shall apply to all open areas between the street wall of any development or enlargement and the street line.
- Where such open areas are sidewalk widenings required pursuant to Section 93-61, or where a sidewalk widening is not required but an open area extends along the entire street line of the zoning lot, no obstructions shall be permitted within such open areas within five feet of the street line. Beyond five feet of the street line, up to a distance of 10 feet from the street line, obstructions shall be limited to seating, tables, and trees planted flush to grade. Any open area provided beyond 10 feet of the street line shall comply with the provisions of paragraphs (b) through (d) of this Section, as applicable.
- All open areas less than 1,200 square feet in area, or open areas of any size but with a width or depth of less than 30 feet, shall be paved or contain landscaping. Paved areas shall be at the same elevation as the adjoining sidewalk or any adjoining public access area required pursuant to this Chapter.
- All open areas at least 1,200 square feet in area, and with a width and depth of at least 30 feet, shall be paved and contain landscaping. Paved areas shall not be more than 2 feet, 6 inches above or below the level of the adjoining sidewalk or any adjoining public access area required pursuant to this Chapter.
- Open areas described in paragraphs (b) and (c) of this Section may be occupied by features, equipment and appurtenances normally found in public parks and playgrounds, as listed in Section 37-726 (Permitted obstructions). In addition, gates or fences shall be permitted for open areas described in paragraph (c) of this Section, provided such gates are fully open during business hours, such gates or fences are not higher than five feet, and are a minimum of 65 percent open to permit visibility of the open area. No parking areas shall be permitted in any open area. Driveways in any open area shall lead directly to an enclosed parking or loading facility, except that portes-cocheres are allowed in any open area on zoning lots with at least 80,000 square feet of lot area. Building trash storage facilities and mechanical equipment shall be screened by a wall or planted area sufficient to visually conceal these facilities from the street or any public access area. All paved areas shall be accessible to the public during business hours and have lighting with a minimum level of two foot candles. Edges of planters in all landscaped areas shall not be higher than 2 feet, 6 inches above the level of any adjacent paved area.
Public access shall be provided for special sites as specified in this Section, inclusive. In the event of a conflict between the provisions of this Section, inclusive, and any underlying regulation, the provisions of this Section shall govern.
No building permit shall be issued for any development or enlargement on such sites other than for an ERY Culture, Festival and Exhibit Facility until the Chairperson of the City Planning Commission certifies to the Department of Buildings that the provisions of this Section have been met.
An application for such certification shall be filed with the Chairperson showing the plan of the zoning lot; a site plan indicating the area and dimensions of all required public access areas and the location of all proposed buildings, and a detailed plan or plans demonstrating compliance with the provisions of this Section. For certifications relating to the ERY High Line and, if applicable, the Tenth Avenue Spur, the requirements set forth in paragraph (h) of Section 93-71, shall apply. For certifications relating to 450 West 33rd Street, the requirements set forth in Section 93-722 shall apply. For certifications relating to the Ninth Avenue Rail Yard, the requirements set forth in Section 93-732 shall apply.
Plans for public access areas shall be set forth in an instrument in a form acceptable to the City, and setting forth such provisions as necessary to ensure compliance with the provisions of this Section. Such instrument shall be filed and duly recorded in the Borough Office of the City Register of the City of New York and indexed against the property. Such filing and recording of the instrument shall be a precondition for the Chairperson's certification under this Section. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
The Chairperson shall allow for the phased development of public access areas upon certification to the Commissioner of Buildings that a plan has been submitted that provides for the completion of any public access area that is integral to the development of a building or buildings within each phase. The completion of the Cultural Facility Plaza shall be deemed integral only to an ERY Culture, Festival and Exhibit Facility and to no other use or development in the Eastern Rail Yard Subarea A1. Where the public use and enjoyment of a public access area is contingent upon development on an adjacent zoning lot that has not yet occurred, the Chairperson may allow for the future development of such public access area at the time that the adjacent zoning lot is developed. For the Eastern Rail Yard Subarea A1, such phased development plan may provide for the outdoor plaza described in paragraph (b) of Section 93-71 to be constructed in phases. For 450 West 33rd Street and the Ninth Avenue Rail Yard, such phased development plan shall comply with additional provisions set forth in Sections 93-722 and 93-732, respectively.
For any portion of any development or enlargement other than an ERY Culture, Festival and Exhibit Facility, no temporary certificate of occupancy from the Department of Buildings may be issued for any portion of any development or enlargement with a floor area ratio of 10.0 or more until the Chairperson certifies to the Department of Buildings that the public access area is substantially complete, and the public access area is open to and useable by the public. No permanent certificate of occupancy from the Department of Buildings may be issued for any portion of such development or enlargement with a floor area ratio of 10.0 or more until the Chairperson certifies to the Department of Buildings that the public access area is complete and that all public access requirements of this Section have been met in accordance with the plans for such public access areas. Notwithstanding the foregoing, for zoning lots with multiple buildings for which the Chairperson has certified that a plan has been submitted that provides for the phased development of public access areas through completion of any public access area that is integral to the development of a building or buildings within each phase, such certifications shall be made with respect to substantial completion or completion of the public access areas integral to each such phase, except as provided in paragraph (h) of Section 93-71, and Section 93-732. Issuance of a temporary or permanent certificate of occupancy for any building, or portion of a building, not occupied by an ERY Culture, Festival and Exhibit Facility shall not be conditioned upon the completion, substantial completion or improvement of the Culture Facility Plaza.
For an ERY Culture, Festival and Exhibit Facility, no temporary certificate of occupancy from the Department of Buildings may be issued for such ERY Culture, Festival and Exhibit Facility until the Chairperson certifies to the Department of Buildings that the Culture Facility Plaza described in paragraph (j) of Section 93-71 is substantially complete and open to and useable by the public and no permanent certificate of occupancy from the Department of Buildings may be issued for the ERY Culture, Festival and Exhibit Facility until the Chairperson certifies to the Department of Buildings that the Culture Facility Plaza is complete. If a moveable portion of the ERY Culture, Festival and Exhibit Facility is not initially constructed as part of the ERY Culture, Festival and Exhibit Facility but is constructed at a later date, any closure of the Culture Facility Plaza necessary for such construction shall not affect the validity of any certificate of occupancy previously issued for the ERY Culture, Festival and Exhibit Facility. No temporary certificate of occupancy for the moveable portion that is thereafter constructed, or an amended temporary certificate of occupancy for the ERY Culture, Festival and Exhibit Facility that includes the moveable portion, may be issued by the Department of Buildings until the Chairperson certifies to the Department of Buildings that the reconstructed Culture Facility Plaza is substantially complete and open to and useable by the public and no permanent certificate of occupancy for the moveable portion that is thereafter constructed, or an amended permanent certificate of occupancy for the ERY Culture, Festival and Exhibit Facility that includes the moveable portion, may be issued by the Department of Buildings until the Chairperson certifies to the Department of Buildings that the reconstructed Culture Facility Plaza is complete.
Any development in the Eastern Rail Yard Subarea A1 shall provide public access areas in accordance with the following requirements:
(a) Amount of public access areas
Public access areas shall be provided in an amount not less than 55 percent of the lot area of the zoning lot. At least 40 percent of the lot area of the zoning lot shall be publicly accessible and open to the sky. At least an additional 15 percent of the lot area of the zoning lot shall be publicly accessible and may be either open or enclosed. Such open or enclosed areas shall be comprised of the types of public access areas listed in paragraphs (b) through (f), and paragraphs (h) and (j), of this Section. For purposes of determining compliance with such 55 percent and 40 percent requirements, the Culture Facility Plaza, any portion of the connection to the High Line allowed to be covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility pursuant to paragraph (f), and any portion of the connection to the High Line that is not required to have a clear height of 60 feet pursuant to paragraph (f) shall be deemed publicly accessible and open to the sky at all times, including any time when a moveable portion of an ERY Culture, Festival and Exhibit Facility extends over the Culture Facility Plaza or the connection to the High Line. Open areas may also include the area of the sidewalk widening along Eleventh Avenue required pursuant to Section 93-61 and, at the option of the owner, the Tenth Avenue Spur. If the Cultural Facility Plaza is closed during the construction of the moveable portion of the ERY Culture, Festival and Exhibit Facility, the amount of publicly accessible open space shall not be considered reduced during such period.
All public access areas listed in this Section, other than the ERY High Line and the Tenth Avenue Spur, shall be accessible to the public, as follows:
Public access areas shall be provided in an amount not less than 55 percent of the lot area of the zoning lot. At least 40 percent of the lot area of the zoning lot shall be publicly accessible and open to the sky. At least an additional 15 percent of the lot area of the zoning lot shall be publicly accessible and may be either open or enclosed. Such open or enclosed areas shall be comprised of the types of public access areas listed in paragraphs (b) through (f), and paragraphs (h) and (j), of this Section. For purposes of determining compliance with such 55 percent and 40 percent requirements, the Culture Facility Plaza, any portion of the connection to the High Line allowed to be covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility pursuant to paragraph (f), and any portion of the connection to the High Line that is not required to have a clear height of 60 feet pursuant to paragraph (f) shall be deemed publicly accessible and open to the sky at all times, including any time when a moveable portion of an ERY Culture, Festival and Exhibit Facility extends over the Culture Facility Plaza or the connection to the High Line. Open areas may also include the area of the sidewalk widening along Eleventh Avenue required pursuant to Section 93-61 and, at the option of the owner, the Tenth Avenue Spur. If the Cultural Facility Plaza is closed during the construction of the moveable portion of the ERY Culture, Festival and Exhibit Facility, the amount of publicly accessible open space shall not be considered reduced during such period.
All public access areas listed in this Section, other than the ERY High Line and the Tenth Avenue Spur, shall be accessible to the public, as follows:
(1) unenclosed public access areas shall be accessible between the hours of 6:00 a.m. and 1:00 a.m., except that any portions of the outdoor plaza, as described in paragraph (b) of this Section, designed and constructed for purposes of vehicular use, shall be accessible at all times, except as necessary to perform maintenance and repairs or address hazardous or emergency conditions;
(2) enclosed portions of the through block connection and connection to the public plaza, described in paragraphs (d) and (e) of this Section, shall be accessible to the public between the hours of 8:00 a.m. and 10:00 p.m.; and
(3) upon completion of the Tenth Avenue bridge, described in paragraph (g) of this Section, access between the bridge and the outdoor plaza shall be provided by means of the through block connection between the hours of 6:00 a.m. and 1:00 a.m.
All public access areas, other than the ERY High Line and the Tenth Avenue Spur, shall include public space signage erected at conspicuous locations. Such signs shall include the statement "Open to the Public," followed by the hours of operation specified in this paragraph (a). The public space signage for the Culture Facility Plaza may include additional information, consistent with the provisions of paragraph (j) of this Section.
(b) Outdoor plaza
A publicly accessible space, open to the sky (hereinafter referred to as the "outdoor plaza"), shall be located within the area bounded by West 33rd Street, the southerly prolongation of the eastern sidewalk widening line of Hudson Boulevard East, a line 250 feet north of and parallel to West 30th Street, Eleventh Avenue, a line 220 feet south of and parallel to West 33rd Street, and the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West. Such open area may extend beyond such boundaries and have necessary grade changes, and up to 10 percent of the area of such outdoor plaza may be covered by a building or other structure
In addition, a building containing eating or drinking places and uses listed in Use Groups 6A and 6C may be located within the outdoor plaza (but shall not be included as public access area pursuant to paragraph (a) of Section 93-71), provided that any such building:
A publicly accessible space, open to the sky (hereinafter referred to as the "outdoor plaza"), shall be located within the area bounded by West 33rd Street, the southerly prolongation of the eastern sidewalk widening line of Hudson Boulevard East, a line 250 feet north of and parallel to West 30th Street, Eleventh Avenue, a line 220 feet south of and parallel to West 33rd Street, and the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West. Such open area may extend beyond such boundaries and have necessary grade changes, and up to 10 percent of the area of such outdoor plaza may be covered by a building or other structure
In addition, a building containing eating or drinking places and uses listed in Use Groups 6A and 6C may be located within the outdoor plaza (but shall not be included as public access area pursuant to paragraph (a) of Section 93-71), provided that any such building:
(1) is located within the area west of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West and within 400 feet of West 30th Street;
(2) covers no more than 3,600 square feet of the zoning lot at the level of the outdoor plaza and above;
(3) contains no more than 7,200 square feet of floor area at the level of the outdoor plaza and above, and no more than 3,600 square feet of floor area below the level of the outdoor plaza;
(4) has a maximum north-south dimension of 85 feet at the level of the outdoor plaza and above;
(5) is located such that the maximum east-west dimension measured along a line 355 feet from West 30th Street is 40 feet at the level of the outdoor plaza and above. For portions of the building located north or south of such line, the maximum east-west dimension shall increase at a rate of one foot in the east-west dimension for every four feet in the north-south dimension from such line, up to a maximum east-west dimension of 60 feet; and
(6) has a maximum perimeter wall height of 24 feet, and a maximum building height of 30 feet. Above a height of 24 feet, no portion of a building may penetrate a sky exposure plane that begins at a height of 24 feet above the perimeter walls and rises over the building at a slope of 2.5 feet of horizontal distance for each foot of vertical distance. Such heights shall be measured from the highest level of the adjoining portions of the outdoor plaza.
No building location or setback requirements shall apply to any building walls facing the northern, eastern or southern boundaries of the outdoor plaza.
Building walls fronting upon the western boundary of the outdoor plaza shall extend along at least 70 percent of the length of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West and shall rise to a minimum height of 90 feet and a maximum height of 120 feet. Above a height of 120 feet, a setback at least 20 feet in depth is required from such prolongation line. However, such building wall may rise without setback at such prolongation line, provided the aggregate width of such building wall does not exceed 50 percent of the width of such line and provided all other portions of the building that exceed a height of 120 feet are set back at least 20 feet from such prolongation line at a height not lower than 90 feet.
The retail and glazing requirements of Section 93-14 (Ground Floor Level Requirements) shall apply to at least 70 percent of the length of all building walls facing each side of the outdoor plaza, except that such retail requirements shall not apply to any building, or portion of a building, located west of the southerly prolongation of the eastern sidewalk widening line of Hudson Boulevard East and within 220 feet of West 30th Street containing uses in Use Group 3 or 4 or an ERY Culture, Festival and Exhibit Facility.
Building walls fronting upon the western boundary of the outdoor plaza shall extend along at least 70 percent of the length of the southerly prolongation of the western sidewalk widening line of Hudson Boulevard West and shall rise to a minimum height of 90 feet and a maximum height of 120 feet. Above a height of 120 feet, a setback at least 20 feet in depth is required from such prolongation line. However, such building wall may rise without setback at such prolongation line, provided the aggregate width of such building wall does not exceed 50 percent of the width of such line and provided all other portions of the building that exceed a height of 120 feet are set back at least 20 feet from such prolongation line at a height not lower than 90 feet.
The retail and glazing requirements of Section 93-14 (Ground Floor Level Requirements) shall apply to at least 70 percent of the length of all building walls facing each side of the outdoor plaza, except that such retail requirements shall not apply to any building, or portion of a building, located west of the southerly prolongation of the eastern sidewalk widening line of Hudson Boulevard East and within 220 feet of West 30th Street containing uses in Use Group 3 or 4 or an ERY Culture, Festival and Exhibit Facility.
(c) Public plaza
A publicly accessible space, (hereinafter referred to as a "public plaza"), shall be provided at the intersection of Tenth Avenue and West 30th Street. Such public plaza shall have a minimum area of 12,000 square feet with a minimum frontage of 180 feet along Tenth Avenue and a minimum frontage of 60 feet along West 30th Street. Such public plaza shall be open to the sky except that such space may be covered by the ERY High Line structure, including any connections to the ERY High Line or other design features, as well as a building or portion of a building as allowed pursuant to Section 93-514, paragraph (a)(4), except that no building or portion of a building may encroach within the area that is within 60 feet of Tenth Avenue and 180 feet of West 30th Street. In addition, no more than 50 percent of the public plaza shall be covered by the permitted obstructions described in Section 37-726, paragraph (a), as well as any vents or shafts that are placed by the Department of Environmental Protection within the portion of the public plaza that is subject to an access easement.
Such public plaza shall contain the following amenities:
A publicly accessible space, (hereinafter referred to as a "public plaza"), shall be provided at the intersection of Tenth Avenue and West 30th Street. Such public plaza shall have a minimum area of 12,000 square feet with a minimum frontage of 180 feet along Tenth Avenue and a minimum frontage of 60 feet along West 30th Street. Such public plaza shall be open to the sky except that such space may be covered by the ERY High Line structure, including any connections to the ERY High Line or other design features, as well as a building or portion of a building as allowed pursuant to Section 93-514, paragraph (a)(4), except that no building or portion of a building may encroach within the area that is within 60 feet of Tenth Avenue and 180 feet of West 30th Street. In addition, no more than 50 percent of the public plaza shall be covered by the permitted obstructions described in Section 37-726, paragraph (a), as well as any vents or shafts that are placed by the Department of Environmental Protection within the portion of the public plaza that is subject to an access easement.
Such public plaza shall contain the following amenities:
(1) no less than 120 linear feet of fixed seating;
(2) no less than 12 moveable tables and 48 moveable chairs; and
(3) no less than four trees or multi-stemmed equivalents measuring at least four inches in caliper at the time of planting, which trees or multi-stemmed equivalents may be planted in a planting bed. In addition, such public plaza shall contain at least two of the following additional amenities:
(i) artwork;
(ii) water features; or
(iii) food service located in a retail space directly accessible from the public plaza.
The glazing requirements of Section 93-14, paragraph (c), shall apply to at least 70 percent of the length of all building walls, other than the building walls of any facility operated by the Long Island Rail Road, or its successor, facing each side of the public plaza. In addition, at least 25 percent of the frontage of all building walls facing the portion of the public plaza that is within 60 feet of Tenth Avenue and 180 feet of West 30th Street shall be occupied by uses listed in Use Groups 6A and 6C or the connection to the public plaza described in paragraph (e) of this Section.
(d) Through block connection
A publicly accessible through block connection shall be provided connecting the outdoor plaza with the Tenth Avenue sidewalk within 50 feet or anywhere north of the center line of West 32nd Street. Public access shall also be provided between such through block connection and the Tenth Avenue bridge at the time such bridge is constructed pursuant to paragraph (g) of this Section, and may connect to other public access areas or sidewalks. Such through block connection may be open to the sky or enclosed, need not be linear and may have necessary grade changes.
Such through block connection shall have a minimum width of 30 feet and any enclosed portion shall have a minimum height of 30 feet. As an alternative, if an enclosed atrium space adjacent to the outdoor plaza is provided as part of the through block connection that meets all the following dimensional requirements: (1) comprises no less than 4,000 square feet with a minimum height of 60 feet and a minimum depth of 50 feet as measured by a line parallel from the building wall facing the outdoor plaza; (2) is free of building structural obstructions other than vertical circulation and other elements occupying no more than 500 square feet in the aggregate; and (3) contains interior walls facing such area that comply with the ground floor retail use requirements of Section 93-14, paragraph (a), then such through block connection may: (i) have a minimum width of 24 feet; and (ii) have a minimum height of 34 feet for at least 70 percent of the aggregate enclosed area of the through block connection (including the atrium), provided that no portion of the through block connection shall have a minimum height less than 17 feet.
The retail and glazing requirements of Section 93-14 shall apply to at least 50 percent of the length of all building walls facing each side of the through block connection (or, if enclosed, the interior walls facing the through block connection). The through block connection may be occupied by the following permitted obstructions: vertical circulation elements including escalators, stairs and elevators, columns and lighting elements, provided that such permitted obstructions shall not occupy more than 20 percent of the through block connection, and a single path of travel no less than 24 feet in width is maintained. Vertical circulation elements traversing the grade changes of the through block connection shall be considered a part of the through block connection and not an obstruction.
A publicly accessible through block connection shall be provided connecting the outdoor plaza with the Tenth Avenue sidewalk within 50 feet or anywhere north of the center line of West 32nd Street. Public access shall also be provided between such through block connection and the Tenth Avenue bridge at the time such bridge is constructed pursuant to paragraph (g) of this Section, and may connect to other public access areas or sidewalks. Such through block connection may be open to the sky or enclosed, need not be linear and may have necessary grade changes.
Such through block connection shall have a minimum width of 30 feet and any enclosed portion shall have a minimum height of 30 feet. As an alternative, if an enclosed atrium space adjacent to the outdoor plaza is provided as part of the through block connection that meets all the following dimensional requirements: (1) comprises no less than 4,000 square feet with a minimum height of 60 feet and a minimum depth of 50 feet as measured by a line parallel from the building wall facing the outdoor plaza; (2) is free of building structural obstructions other than vertical circulation and other elements occupying no more than 500 square feet in the aggregate; and (3) contains interior walls facing such area that comply with the ground floor retail use requirements of Section 93-14, paragraph (a), then such through block connection may: (i) have a minimum width of 24 feet; and (ii) have a minimum height of 34 feet for at least 70 percent of the aggregate enclosed area of the through block connection (including the atrium), provided that no portion of the through block connection shall have a minimum height less than 17 feet.
The retail and glazing requirements of Section 93-14 shall apply to at least 50 percent of the length of all building walls facing each side of the through block connection (or, if enclosed, the interior walls facing the through block connection). The through block connection may be occupied by the following permitted obstructions: vertical circulation elements including escalators, stairs and elevators, columns and lighting elements, provided that such permitted obstructions shall not occupy more than 20 percent of the through block connection, and a single path of travel no less than 24 feet in width is maintained. Vertical circulation elements traversing the grade changes of the through block connection shall be considered a part of the through block connection and not an obstruction.
(e) Connection to public plaza
A public way, open or enclosed, shall be provided connecting the outdoor plaza or the through block connection with the public plaza. Such connection need not be linear and may have necessary grade changes. The retail and glazing requirements of Section 93-14 shall apply to at least 50 percent of the length of all building walls facing each side of such connection (or, if enclosed, the interior walls facing the connection). The minimum clear width of such public way shall be 20 feet. For any portions that are enclosed, the minimum clear height shall be 34 feet within at least 50 percent of the enclosed area of the connection to the public plaza, provided that no portion of the connection to the public plaza shall have a minimum height less than 17 feet. The connection to the public plaza may be occupied by the following permitted obstructions: vertical circulation elements including escalators, stairs and elevators, columns and lighting elements, provided that such permitted obstructions shall not occupy more than 20 percent of the connection to the public plaza and a single path of travel no less than 20 feet in width is maintained. Vertical circulation elements traversing the grade changes of the connection to the public plaza shall be considered a part of the connection to the public plaza and not an obstruction.
A public way, open or enclosed, shall be provided connecting the outdoor plaza or the through block connection with the public plaza. Such connection need not be linear and may have necessary grade changes. The retail and glazing requirements of Section 93-14 shall apply to at least 50 percent of the length of all building walls facing each side of such connection (or, if enclosed, the interior walls facing the connection). The minimum clear width of such public way shall be 20 feet. For any portions that are enclosed, the minimum clear height shall be 34 feet within at least 50 percent of the enclosed area of the connection to the public plaza, provided that no portion of the connection to the public plaza shall have a minimum height less than 17 feet. The connection to the public plaza may be occupied by the following permitted obstructions: vertical circulation elements including escalators, stairs and elevators, columns and lighting elements, provided that such permitted obstructions shall not occupy more than 20 percent of the connection to the public plaza and a single path of travel no less than 20 feet in width is maintained. Vertical circulation elements traversing the grade changes of the connection to the public plaza shall be considered a part of the connection to the public plaza and not an obstruction.
(f) Connection to High Line
A publicly accessible connection between the High Line and the outdoor plaza (hereinafter referred to as the "connection") shall be provided that has a minimum width, measured parallel to the High Line, of 60 feet and is located east of the Culture Facility Plaza. For a width of 60 feet measured parallel to the High Line, the clear height of the connection shall be at least 60 feet. Above such height, overhangs of the 60 foot width dimension of the connection shall be permitted by the movable portion of the ERY Culture, Festival and Exhibit Facility, provided that the angle of such overhang is a maximum of 14 degrees east of the vertical extension of the western edge of such 60 foot width, as measured from the intersection of such vertical extension with the 60 foot clear height of the connection. Additionally, such overhang shall project over no more than 16 feet of the 60 foot width dimension. Any portion of the connection east of the minimum 60 foot width shall, if covered, have a minimum clear height of 60 feet. The movable portion of the ERY Culture, Festival and Exhibit Facility shall be permitted to overhang any portion of the connection west of such minimum 60 foot width, provided that the angle of such overhanging portion is a maximum of 14 degrees measured at the western edge of the connection at its ground level. The glazing requirements of Section 93-14, paragraph (c), shall apply to at least 50 percent of the length of all building walls facing the connection.
A publicly accessible connection between the High Line and the outdoor plaza (hereinafter referred to as the "connection") shall be provided that has a minimum width, measured parallel to the High Line, of 60 feet and is located east of the Culture Facility Plaza. For a width of 60 feet measured parallel to the High Line, the clear height of the connection shall be at least 60 feet. Above such height, overhangs of the 60 foot width dimension of the connection shall be permitted by the movable portion of the ERY Culture, Festival and Exhibit Facility, provided that the angle of such overhang is a maximum of 14 degrees east of the vertical extension of the western edge of such 60 foot width, as measured from the intersection of such vertical extension with the 60 foot clear height of the connection. Additionally, such overhang shall project over no more than 16 feet of the 60 foot width dimension. Any portion of the connection east of the minimum 60 foot width shall, if covered, have a minimum clear height of 60 feet. The movable portion of the ERY Culture, Festival and Exhibit Facility shall be permitted to overhang any portion of the connection west of such minimum 60 foot width, provided that the angle of such overhanging portion is a maximum of 14 degrees measured at the western edge of the connection at its ground level. The glazing requirements of Section 93-14, paragraph (c), shall apply to at least 50 percent of the length of all building walls facing the connection.
(g) Tenth Avenue bridge
A publicly accessible pedestrian bridge shall be provided over Tenth Avenue linking the through block connections required pursuant to paragraph (d) of this Section and paragraph (a) of Section 93-72 (Public Access Areas at 450 West 33rd Street). Such bridge need not be constructed until the 450 West 33rd Street through block connection has been completed. Such bridge may be open or enclosed, have a minimum clear width of 30 feet and, if enclosed, have a minimum clear height of 15 feet. Such bridge shall be located within 10 feet of the center line of West 32nd Street and be at the same elevation as the through block connection required pursuant to paragraph (a) of Section 93-72.
A publicly accessible pedestrian bridge shall be provided over Tenth Avenue linking the through block connections required pursuant to paragraph (d) of this Section and paragraph (a) of Section 93-72 (Public Access Areas at 450 West 33rd Street). Such bridge need not be constructed until the 450 West 33rd Street through block connection has been completed. Such bridge may be open or enclosed, have a minimum clear width of 30 feet and, if enclosed, have a minimum clear height of 15 feet. Such bridge shall be located within 10 feet of the center line of West 32nd Street and be at the same elevation as the through block connection required pursuant to paragraph (a) of Section 93-72.
(h) ERY High Line and Tenth Avenue Spur
The ERY High Line shall be provided as a publicly accessible open area. The Tenth Avenue Spur may, at the option of the owner, also be provided as a publicly accessible open area.
The ERY High Line shall be provided as a publicly accessible open area. The Tenth Avenue Spur may, at the option of the owner, also be provided as a publicly accessible open area.
(1) In order to meet the public access area requirements of Section 93-71, paragraph (a), and this paragraph (h), the following shall be provided for the ERY High Line, and shall, if the owner has elected to include the Tenth Avenue Spur as a public access area, be further provided for the Tenth Avenue Spur:
(i) Payment of the High Line Rehabilitation Deposit; or subject to entry into construction-related agreements with the City or its designee, completion of the rehabilitation of the ERY High Line and, if applicable, the Tenth Avenue Spur, not later than March 31, 2013, subject to a determination of force majeure by the City in accordance with the terms thereof. If the owner has elected to perform the rehabilitation work, then all such work shall be completed in accordance with plans and specifications prepared by or on behalf of the City;
(ii) Payment of the High Line Landscape Improvement Deposit;
(iii) Provision of High Line Maintenance Funding;
(iv) An easement agreement allowing use of the ERY High Line for public space in accordance with the requirements of this paragraph (h), as well as for use and access for rehabilitation, improvement, maintenance and repair purposes, acceptable to the City.
Such requirements shall be set forth in agreements or instruments in a form acceptable to the City, including such provisions as are necessary to ensure compliance with the provisions of this Section. The execution of such agreements by the owner, and mortgagees and parties in interest of the owner, and, where appropriate, the filing and recordation of such instruments in the Borough Office of the City Register of the City of New York, indexed against the property, shall be a precondition to the Chairperson's certification to the Department of Buildings for a building permit under Section 93-70. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
(2) No certification for the phased development of public access areas on the Eastern Rail Yard Subarea A1 under Section 93-70 shall be permitted unless the ERY High Line is included as a public access area for the initial phase in accordance with the provisions of this paragraph (h).
(3) No crane permit shall be granted for construction of a development or enlargement in such initial phase until the Chairperson certifies to the Department of Buildings that: (i) either the High Line Rehabilitation Deposit has been made or all construction documents and instruments necessary for accomplishment of the rehabilitation of the ERY High Line and, if applicable, the Tenth Avenue Spur, in accordance with paragraph (h)(1)(i) of this Section, have been executed and delivered; and (ii) the High Line Landscape Improvement Deposit has been made.
(4) No temporary or permanent certificate of occupancy for a development or enlargement in such initial phase shall be granted unless the Chairperson certifies to the Department of Buildings that (i) either the High Line Rehabilitation Deposit has been previously furnished or the rehabilitation of the ERY High Line and, if applicable, the Tenth Avenue Spur, have been completed in accordance with the construction documents and instruments; (ii) the initial installment of High Line Maintenance Funding has been delivered, provided and to the extent that the ERY High Line and, if applicable, the Tenth Avenue Spur, have been substantially completed and are open for use by the public; and (iii) the easement agreement described in paragraph (h)(1)(iv) of this Section, is in effect for the ERY High Line. The requirement for a certification of substantial completion of public access areas before the granting of a temporary certificate of occupancy for the development or enlargement within such phase pursuant to Section 93-70 shall not apply with respect to the ERY High Line and, if applicable, the Tenth Avenue Spur.
(5) Nothing herein shall be construed to affect any obligation of the owner to make the High Line Rehabilitation Deposit at an earlier date, in accordance with the terms of agreements or instruments entered into by the parties, or to complete rehabilitation work for the ERY High Line and, if applicable, the Tenth Avenue Spur, by March 31, 2013, subject to a determination of force majeure by the City in accordance with the terms of such agreements.
(6) Use by the City of the High Line Landscape Improvement Deposit for improvement of the ERY High Line and, if applicable, the Tenth Avenue Spur, shall be subject to approval by the Chairperson, based upon a determination that the design and location of access points to the ERY High Line and, if applicable, the Tenth Avenue Spur, have been arranged such that public use thereof will not result in any significant adverse impacts with respect to transit or pedestrians.
(i) Certifications for phased development pursuant to Section 93-70 granted before May 31, 2012
If a certification for the phased development of public access areas on the Eastern Rail Yard Subarea A1 under Section 93-70 was granted before May 31, 2012, such certification shall expire 45 days following such date and shall thereupon no longer be in force and effect. Within said 45-day period, a new application for certification pursuant to Section 93-70 and Section 93-71, paragraph (h), shall be filed by the owner which shall include the ERY High Line and, if applicable, the Tenth Avenue Spur, as public access areas associated with the initial phase, in addition to any other public access areas previously so certified. The expiration of any certification under Section 93-70 granted before May 31, 2012, shall not affect the validity of any permit issued by the Department of Buildings prior to the expiration of such 45-day period, provided the new application under Section 93-70 and Section 93-71, paragraph (h), is made within such 45-day period.
In the event that a certification for the phased development of public access areas on the Eastern Rail Yard Subarea A1 under Section 93-70 was granted before May 31, 2012, and a crane permit for the construction of a development or enlargement within such initial phase was granted prior to 45 days after May 31, 2012, the preconditions to issuance of a crane permit set forth in Section 93-71, paragraph (h), shall be prerequisites for the grant of any new certification for phased development made under this paragraph (i).
If a certification for the phased development of public access areas on the Eastern Rail Yard Subarea A1 under Section 93-70 was granted before May 31, 2012, such certification shall expire 45 days following such date and shall thereupon no longer be in force and effect. Within said 45-day period, a new application for certification pursuant to Section 93-70 and Section 93-71, paragraph (h), shall be filed by the owner which shall include the ERY High Line and, if applicable, the Tenth Avenue Spur, as public access areas associated with the initial phase, in addition to any other public access areas previously so certified. The expiration of any certification under Section 93-70 granted before May 31, 2012, shall not affect the validity of any permit issued by the Department of Buildings prior to the expiration of such 45-day period, provided the new application under Section 93-70 and Section 93-71, paragraph (h), is made within such 45-day period.
In the event that a certification for the phased development of public access areas on the Eastern Rail Yard Subarea A1 under Section 93-70 was granted before May 31, 2012, and a crane permit for the construction of a development or enlargement within such initial phase was granted prior to 45 days after May 31, 2012, the preconditions to issuance of a crane permit set forth in Section 93-71, paragraph (h), shall be prerequisites for the grant of any new certification for phased development made under this paragraph (i).
(j) Culture Facility Plaza
A publicly accessible space located east of and abutting the non-moveable portion of an ERY Culture, Festival and Exhibit Facility, and bounded to the north by the outdoor plaza and to the south by the ERY High Line shall be provided. During times when the Culture Facility Plaza is not covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility, the Culture Facility Plaza may be used for purposes of outdoor events related to an ERY Culture, Festival and Exhibit Facility. Outdoor installations for such events, including seating, shall be restricted to the Culture Facility Plaza. All such events shall be open and accessible to the general public free of admission charge, provided that ticketed events with tickets available on a first come, first served, or timed basis, shall be permitted. During all times when the Culture Facility Plaza is not used for an ERY Culture, Festival and Exhibit Facility event or covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility, the Culture Facility Plaza shall be open and accessible to the public between the hours of 6:00 a.m. and 1:00 a.m. Notwithstanding any other provision, the Culture Facility Plaza may be closed to the public not more than 12 days each calendar year for an event related to the ERY Culture, Festival and Exhibit Facility, provided that not less than five days prior to any such closing, notice is given to the applicable community board and is posted at conspicuous locations at such plaza. No building or portion of a building that is not used for an ERY Culture, Festival and Exhibit Facility shall have any obligation to comply with the requirements of paragraph (a), or this paragraph (j), of this Section related to the Culture Facility Plaza.
A publicly accessible space located east of and abutting the non-moveable portion of an ERY Culture, Festival and Exhibit Facility, and bounded to the north by the outdoor plaza and to the south by the ERY High Line shall be provided. During times when the Culture Facility Plaza is not covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility, the Culture Facility Plaza may be used for purposes of outdoor events related to an ERY Culture, Festival and Exhibit Facility. Outdoor installations for such events, including seating, shall be restricted to the Culture Facility Plaza. All such events shall be open and accessible to the general public free of admission charge, provided that ticketed events with tickets available on a first come, first served, or timed basis, shall be permitted. During all times when the Culture Facility Plaza is not used for an ERY Culture, Festival and Exhibit Facility event or covered by the moveable portion of an ERY Culture, Festival and Exhibit Facility, the Culture Facility Plaza shall be open and accessible to the public between the hours of 6:00 a.m. and 1:00 a.m. Notwithstanding any other provision, the Culture Facility Plaza may be closed to the public not more than 12 days each calendar year for an event related to the ERY Culture, Festival and Exhibit Facility, provided that not less than five days prior to any such closing, notice is given to the applicable community board and is posted at conspicuous locations at such plaza. No building or portion of a building that is not used for an ERY Culture, Festival and Exhibit Facility shall have any obligation to comply with the requirements of paragraph (a), or this paragraph (j), of this Section related to the Culture Facility Plaza.
For the purposes of this Section 93-72, inclusive, 450 West 33rd Street shall be considered the area bounded by the eastern street line of Tenth Avenue, the northern street line of West 31st Street, a line 302 feet east of the eastern street line of Tenth Avenue and the southern street line of West 33rd Street. Such area shall include the tax lots located at Block 729, Lots 1 and 15, existing on April 29, 2014. Any development or enlargement in such area shall provide public access areas in accordance with the provisions of this Section. However, if a special permit has been granted for the development of an arena pursuant to Section 74-41 in the area bounded by the western street line of Ninth Avenue, the northern street line of West 31st Street, a line 498 feet west of the western street line of Ninth Avenue and the southern street line of West 33rd Street, the provisions of this Section may be waived or modified in conjunction with such special permit. All public access areas listed in this Section shall be accessible to the public between the hours of 6:00 a.m. and 1:00 a.m.
- Through block connection
A publicly accessible through block connection shall be provided within 10 feet of the prolonged center line of West 32nd Street, at an elevation that connects the Tenth Avenue pedestrian bridge required pursuant to paragraph (g) in Section 93-71 with the Dyer Avenue Platform required pursuant to paragraph (b) of this Section and paragraph (e) of Section 93-73 (Public Access Areas on the Ninth Avenue Rail Yard). Public access shall also be provided between such through block connection and the Tenth Avenue sidewalk.
For developments or enlargements where 75 percent or less of the total floor area existing on the zoning lot on January 19, 2005, has been demolished, such through block connection shall be open or enclosed and have a minimum clear width of 30 feet. If enclosed, at least 75 percent of such through block connection shall have a minimum clear height of 30 feet, and the remainder shall have a minimum clear height of 20 feet.
For developments or enlargements where more than 75 percent of the total floor area existing on the zoning lot on January 19, 2005, is demolished, such through block connection shall have a minimum width of 60 feet and a minimum clear path of 20 feet, and have retail uses fronting upon at least 50 percent of its northern and southern boundaries. At least 60 percent of such through block connection shall be enclosed, with an average clear height of 60 feet and a roof of transparent material that allows for natural daylight to enter. Direct access shall be provided to any building adjacent to such through block connection. The maximum height of a building wall along the southern boundary of the through block connection shall not exceed the average height of the enclosed portion, or the height at which an arched or angled ceiling of the enclosed through block connection begins, whichever is less. Any portion of a building that exceeds such height shall be set back at least 20 feet in depth from the southern boundary of the through block connection. Any portion of such through block connection that is open to the sky shall comply with the provisions for public plazas set forth in Sections 37-718, 37-726, 37-728, 37-741, 37-742, 37-743, 37-744, 37-75, 37-76 and 36-77.
An enlargement that does not increase the total floor area on the zoning lot to more than 1,373,700 square feet, shall not be considered an enlargement for purposes of this paragraph (a). - Dyer Avenue Platform
A permanent easement shall be provided along the eastern edge of 450 West 33rd Street, as shown on Map 1 (Subdistrict B: 450 West 33rd Street and Ninth Avenue Rail Yard Public Access Area Plan) in Appendix B of this Chapter, for the purposes of constructing the Dyer Avenue Platform required pursuant to paragraph (d) of Section 93-73. Such easement shall have a minimum width of 33 feet. Any amenities required by paragraph (d) of Section 93-73 may be located within such easement. - West 31st Street Passageway
A publicly accessible passageway space, (hereinafter referred to as the "West 31st Street passageway") shall be provided connecting the Tenth Avenue podium required pursuant to paragraph (d) of this Section to the Dyer Avenue Platform required pursuant to paragraph (d) of Section 93-73, as shown on Map 1 in Appendix B. The West 31st Street passageway shall be located at the same elevation as the Dyer Avenue Platform. Such space shall be located within 35 feet of West 31st Street, have a minimum clear path of 10 feet and be visually open to West 31st Street except for structural elements of the building at 450 West 33rd Street. - Tenth Avenue podium
- Location and minimum dimensions
A publicly accessible area (hereinafter referred to as the "Tenth Avenue podium") shall be provided at the corner of Tenth Avenue and West 31st Street, as shown on Map 1 in Appendix B. The Tenth Avenue podium shall have a minimum area of 1,800 square feet, be located at the same elevation as the Dyer Avenue Platform required pursuant to paragraph (d) of Section 93-73, and shall connect to the West 31st Street passageway required pursuant to paragraph (c) of this Section. - Required amenities
The Tenth Avenue podium shall contain a minimum of four trees and be directly accessible from West 31st Street by a staircase and elevator. The stair and the adjoining area shall be open to West 31st Street except for columns and structural elements of the 450 West 33rd Street building.
- Location and minimum dimensions
Public access areas at 450 West 33rd Street provided pursuant to the requirements of Section 93-72 shall comply with the applicable design reference standards set forth in paragraph (a), and the maintenance provisions of paragraph (b) of this Section.
- Design reference standards
The public access areas required by paragraphs (c) and (d) of Section 93-72 shall comply with the following applicable design standards:- at least two litter receptacles in such public access areas shall be provided;
- the public access areas at 450 West 33rd Street shall provide the following public signage system:
- One entry plaque shall be provided in each of the following locations:
- the Dyer Avenue access point to the West 31st Street Passageway;
- the Tenth Avenue Podium access point to the West 31st Street Passageway; and
- the street level entrance to the Tenth Avenue Podium.
- Each entry plaque is subject to the signage standards as set forth in paragraphs (a)(1) through (a)(4) of Section 37-751 (Public space signage systems).
- Each entry plaque shall be mounted on a wall, a permanent free-standing post, or on a post located within a planter, with its center five feet above the elevation of the nearest walkable pavement. The maximum height of such free-standing post shall be six feet, with a maximum width and depth of 16 inches. Each entry plaque shall be in a position that clearly identifies the entry into the portion of the public access areas at 450 West 33rd Street that such plaque is provided in connection with, and placed so that the entire entry plaque is obvious and directly visible, without any obstruction, along every line of sight from all paths of pedestrian access to that portion of the public access areas at 450 West 33rd Street.
- A minimum of two information plaques, constructed from the same permanent materials as the entry plaque, or combined with one or more of the required entry plaques, shall be provided within the public access areas. Information plaques shall be mounted on a wall, a permanent free-standing post, or on a post located within a planter, with its center five feet above the elevation of the nearest walkable pavement. The maximum height of such free-standing post shall be six feet, with a maximum width and depth of 16 inches.
- The information plaque is subject to the signage standards as set forth in paragraphs (b)(1) through (b)(6) of Section 37-751, except that paragraph (b)(3) shall be modified to read, "in lettering three-eighths of an inch in height, the words: 'This public access area contains:'" followed by the total linear feet of seating, the type and quantity of trees and the number of additional required amenities, such as moveable seating, that are provided in the portion of the public access area in which the entry plaque or information plaque is provided.
- the minimum level of illumination shall be 1.5 horizontal foot candles (lumens per foot);
- no gates, fences or other barriers shall be permitted within such public access areas; and
- for the purposes of applying the sign regulations to building walls facing public access areas, such public access areas shall be considered streets.
- Maintenance
The owner(s) shall be responsible for the maintenance of all public access areas, including, but not limited to, litter control, management of pigeons and rodents, maintenance of required lighting levels, and the care and replacement of furnishings and vegetation.
For enlargements that do not increase the total floor area on the zoning lot to more than 1,373,700 square feet, in accordance with the provisions of Section 93-732 (Certification for public access areas on the Ninth Avenue Rail Yard), no temporary or permanent certificate of occupancy shall be issued by the Department of Buildings for more than 3,204,000 square feet of floor area developed or enlarged on the Ninth Avenue Rail Yard until the Chairperson of the City Planning Commission certifies to the Commissioner of Buildings that a phasing plan has been submitted requiring the West 31st Street Passageway and the Tenth Avenue Podium, required pursuant to paragraphs (c) and (d) of Section 93-72 (Public Access Areas at 450 West 33rd Street), respectively, to be substantially complete and open to and useable by the public.
For the purposes of this Section 93-73, inclusive, the Ninth Avenue Rail Yard shall be considered the area bounded by the western street line of Ninth Avenue, the northern street line of West 31st Street, a line located 498 feet west of the western street line of Ninth Avenue and the southern street line of West 33rd Street. Such area shall include the tax lots located at Block 729, Lots 50 and 60, existing on April 29, 2014. Any development in such area shall provide public access areas in accordance with the provisions of Section 93-73, inclusive.
Public access areas on the Ninth Avenue Rail Yard shall be comprised of the types of public access areas listed in this Section. Public access areas shall also include the area of the sidewalk widenings along Ninth Avenue and West 33rd Street required pursuant to Section 93-61. The entry plaza and the art plaza, as set forth in paragraphs (a) and (c) of this Section, respectively, shall be subject to the hours of access provisions set forth in Section 37-727. All other public access areas listed in this Section shall be accessible to the public between the hours of 6:00 a.m. and 1:00 a.m.
- Entry Plaza
- Location and minimum dimensions
A publicly accessible space, open to the sky (hereinafter referred to as the "entry plaza"), shall be located within the area bounded by the western street line of Ninth Avenue, the southern street line of West 33rd Street, a line 168 feet south of and parallel to the southern street line of West 33rd Street and a line 60 feet west of and parallel to the western street line of Ninth Avenue, as shown on Map 1 (Subdistrict B: 450 West 33rd Street and Ninth Avenue Rail Yard Public Access Area Plan) in Appendix B of this Chapter. The entry plaza shall have a minimum area of 10,080 square feet, shall have a minimum frontage along Ninth Avenue of 168 feet and shall provide a direct connection to the central plaza required pursuant to paragraph (b) of this Section. No more than 50 percent of the entry plaza area shall be covered by the permitted obstructions described in paragraph (a) of Section 37-726. - Required amenities
The entry plaza shall have the following amenities:- a minimum of eight trees (or other amounts equivalent to a minimum of 32 caliper inches);
- at least 336 linear feet of seating including a minimum of 48 moveable chairs and 12 moveable tables. At least 50 percent of the seating, including movable seats, shall have backs and no more than 50 percent of the seating with backs shall be movable seating;
- two or more planting beds which, in the aggregate, occupy an area of at least 800 square feet. No more than 35 percent of the linear feet of the planting beds shall have bounding walls exceeding 18 inches in height above an adjacent walking surface;
- ground floor transparency, in accordance with the provisions of paragraph (c) of Section 93-14 (Ground Floor Level Requirements), shall apply to at least 70 percent of the length of all building walls facing the entry plaza; and
- one clear pedestrian circulation path with a minimum width of 12 feet shall be provided adjacent to the building facing the entry plaza and shall extend for the full length of the building frontage.
- Location and minimum dimensions
- Central Plaza
- Location and minimum dimensions
A publicly accessible space (hereinafter referred to as the "central plaza"), shall be located within an area bounded by the western street line of Ninth Avenue, a line 168 feet south of and parallel to the southern street line of West 33rd Street, a line 478 feet west of and parallel to the western street line of Ninth Avenue, a line 167 feet north of and parallel to the northern street line of West 31st Street beyond 40 feet of the western street line of Ninth Avenue, a line 40 west of and parallel to the western street line of Ninth Avenue and a line 187 feet north of and parallel to the northern street line of West 31st Street within 40 feet of the western street line of Ninth Avenue, as shown on Map 1 in Appendix B of this Chapter. Except as provided in paragraph (b)(3) of this Section, the central plaza shall have a minimum area of 47,800 square feet, and shall have a minimum north-south dimension of 100 feet as measured from the building walls of the buildings facing onto the central plaza of. The central plaza shall be open to the sky, except:- for the area occupied by the pavilion permitted by paragraph (b)(2)(vii) of this Section; and
- within a line 115 feet west of and parallel to the western street line of Ninth Avenue, a building may cantilever over the central plaza and required circulation paths located therein, provided such cantilever extends no greater than 10 feet over such central plaza.
- Required amenities
The central plaza shall contain the following features and amenities:- Landscaped area
A landscaped area shall be provided and shall contain a minimum of 44 trees (or other amounts equivalent to a minimum of 176 caliper inches), and planting beds which, in the aggregate, occupy an area of at least 7,500 square feet.
Within the area bounded by the western street line of Ninth Avenue and a line drawn 45 feet west of the western street line of Ninth Avenue, a minimum of 1,000 square feet of such total requirement shall be occupied by planting beds. - Seating
A minimum of 725 linear feet of seating shall be provided, with 120 moveable chairs and 30 moveable tables. At least 50 percent of the required seating shall have backs.
Within the area bounded by the western street line of Ninth Avenue and a line drawn 45 feet west of the western street line of Ninth Avenue, a minimum of 50 linear feet of seating of such total requirement shall be provided, of which 50 percent shall have backs. - Event space
The portion of the central plaza located beyond a line drawn 295 feet west of and parallel to the western street line of Ninth Avenue may be used for events (hereinafter referred to as the "event space"). Such event space may be used for events not exceeding a maximum area of 4,500 square feet, except as set forth below for summer public events and winter public events. When the event space is not being used for an event (general public events, summer public events, winter public events and private events), it shall contain a minimum of 192 linear feet of seating, with 96 moveable chairs and 24 moveable tables and, between April 1 and November 15, a minimum of two moveable food carts within the event space or on the periphery thereof. Such tables and chairs shall be in addition to the amount required for the landscaped area in paragraph (b)(2)(ii) of this Section. When the event space is being used for an event (general public events, summer public events, winter public events and private events), the additional tables, chairs and moveable food carts may be removed.- General Public Events
At all times of the year, the event space may be used to host general public events which are open and accessible to the general public and free of admission. During such public events, the event space may contain associated temporary structures and seating. - Summer Public Events
For not more than 75 days between April 1 and November 15, the event space may be used for summer public events which are open and accessible to the general public and free of admission charge, where the temporary structures and seating associated with such summer public events may extend beyond 4,500 square feet, provided that the total area used for such summer public events does not exceed an additional 2,000 square feet and is located beyond a line drawn 295 feet west of and parallel to the western street line of Ninth Avenue. - Winter Public Events
Between November 15 and April 1, an ice skating rink, together with associated temporary structures, may extend beyond 4,500 square feet, provided that the total area used for the ice skating rink together with associated temporary structures does not exceed an additional 2,000 square feet and is located beyond a line drawn 295 feet west of and parallel to the western street line of Ninth Avenue. The ice skating rink shall be open and accessible to the general public, but a fee for use of the ice skating rink may be charged, provided the combined total admission and equipment rental fees do not exceed the highest of such combined fees charged at any one rink operating in a public park. - Private Events
The City Planning Commission may allow the closing of the event space for up to 12 private events per year pursuant to a restrictive declaration acceptable to the City and recorded in the Office of the City Register for New York County and indexed against the property.For all events specified in this Section, temporary structures or seating associated with such an event (general public events, summer public events, winter public events and private events) permitted by this paragraph may be installed in the event space, provided the circulation paths required in paragraph (b)(2)(iv) of this Section remain unobstructed at all times.
- General Public Events
- Circulation paths
Circulation paths in the central plaza shall meet the following minimum requirements:- pedestrian circulation paths with an aggregate width of not less than 30 feet shall be provided;
- at least two of the required circulation paths with a minimum clear width of 12 feet shall be located within 20 feet of the facade of each building facing the central plaza;
- in addition to the circulation paths required by paragraph (b)(2)(iv)(a) of this Section, at least two circulation paths shall be provided through the landscaped area required by paragraph (b)(2)(i) of this Section, which connect with the circulation paths required by paragraph (b)(2)(iv)(b) of this Section;
- all circulation paths shall be unobstructed during events held in the event space permitted by paragraph (b)(2)(iii) of this Section; and
- clear paths, with a total minimum aggregate width of 20 feet, shall be located at the boundary between the entry plaza, required pursuant to paragraph (a) of this Section, and the central plaza, required by paragraph (b) of this Section, and at the boundary between the art plaza, required pursuant to paragraph (c) of this Section, and the central plaza, required by paragraph (a) of this Section, provided that up to eight feet of such required clear path may be located within the entry plaza and within the art plaza, respectively, and that all clear paths counted toward the aggregate minimum width required by this paragraph shall be a minimum of 7 feet, 6 inches in clear width, and be located no further than 12 feet apart from one another.
- Transparency
The transparency requirements of paragraph (c) of Section 93-14 (Ground Floor Level Requirements) shall apply to the ground floor level of at least 70 percent of the length of all building walls facing each side of the central plaza. - Retail continuity
At least 40 percent of the frontage of any building fronting on the central plaza shall comply with the retail continuity requirements of paragraph (a) of Section 93-14 and at least 50 percent of the aggregate frontage of all buildings fronting on the central plaza shall comply with the retail continuity requirements of paragraph (a) of Section 93-14. Such retail space shall have a minimum depth of 30 feet measured perpendicular to the wall adjoining the central plaza. - Pavilion
A building (hereinafter referred to as a "pavilion") containing uses listed in Use Groups 6A and 6C may be located within the central plaza, provided that such pavilion, and any seating associated with a use in the pavilion, shall be located at least ten feet west of the prolongation of the east face of the building fronting on the north side of the central plaza. The pavilion shall have a minimum lot coverage of 1,000 square feet and a maximum lot coverage of 3,000 square feet, with a maximum width of 40 feet parallel to Ninth Avenue. Such pavilion shall be no more than one story in height, except such one story limitation may be exceeded by portions of the pavilion allocated to mechanical equipment as well as restrooms and a food preparation kitchen occupying, in the aggregate, no more than 200 square feet area. Such pavilion shall not exceed a height limit of 25 feet, except that the permitted obstructions set forth in Section 33-42, as well as restrooms and a food preparation kitchen located above the level of the first story may be permitted to exceed such height limit provided that the height of such restroom and food preparation kitchen do not exceed ten feet. Seating may be provided for the uses in the pavilion provided that the total area occupied by the pavilion and such associated seating does not exceed a maximum lot coverage of 3,600 square feet and that such seating shall not count towards meeting the seating requirements set forth in paragraphs (b)(2)(ii) and (iii) of this Section. Floor space within the pavilion shall not be considered floor area. At least 60 percent of the exterior walls of the pavilion shall be transparent except for structural supports, provided that 100 percent of the east facing wall of the pavilion shall be transparent except for structural supports.
- Landscaped area
- Alternative design option
Notwithstanding the provisions of paragraph (b)(1) of this Section, the minimum north-south width of the central plaza may be reduced to no less than 80 feet for at least 50 percent of the aggregate frontage of the buildings fronting on the central plaza, provided that such narrowed portion begins no further than 150 feet from the western street line of Ninth Avenue, and further provided that the minimum size of the central plaza is not less than 41,382 square feet. The minimum height of a building wall fronting upon such narrowed portion shall be 45 feet, and the maximum height of such building wall shall not exceed 85 feet. Above a height of 85 feet, the minimum setback distance shall be 10 feet and the minimum distance between buildings fronting on the central plaza shall be 100 feet.
- Art Plaza
- Location and minimum dimensions
A publicly accessible space open to the sky (hereinafter referred to as the "art plaza") shall be located in the area bounded by the western street line of Ninth Avenue, the northern street line of West 31st Street, a line 40 feet west of and parallel to the western street line of Ninth Avenue and a line 187 feet north of and parallel to the northern street line of West 31st Street, as shown on Map 1 in Appendix B. The art plaza shall have a minimum area of 7,480 square feet, a minimum east-west dimension of 40 feet and shall provide a direct connection to the central plaza required pursuant to paragraph (b) of this Section. - Required amenities
The art plaza shall contain the following features and amenities:- a minimum of four trees (or other amounts equivalent to a minimum of 16 caliper inches);
- planting beds which, in the aggregate, occupy an area of at least 410 square feet;
- a minimum of 45 linear feet of seating;
- one or more pieces of artwork. Such artwork may not incorporate addresses, text or logos related to the adjacent building or tenants of such building; and
- the transparency requirements of paragraph (c) of Section 93-14 shall apply to the ground floor level of at least 70 percent of the length of all building walls facing the art plaza.
- Location and minimum dimensions
- Dyer Avenue Platform
- Location and minimum dimensions
A publicly accessible platform shall be constructed over Dyer Avenue connecting West 33rd Street and West 31st Street (hereinafter referred to as the "Dyer Avenue Platform"), as shown on Map 1 in Appendix B. The Dyer Avenue Platform shall include the easement area described in paragraph (b) of Section 93-72 and shall directly connect with the central plaza and the West 31st Street connector required by paragraphs (b) and (e) of this Section, respectively. The Dyer Avenue Platform shall have a minimum east-west dimension of 53 feet and a minimum north-south dimension of 455 feet. However, such minimum east-west dimension may be reduced to accommodate an extension of such existing egress stair in order to adjoin the level of the platform, or to accommodate up to 15 inches of additional exterior wall thickness added to the eastern face of the existing building at 450 West 33rd Street. Except for any portion of the Dyer Avenue Platform which on April 29, 2014, was covered by the building located at 450 West 33rd Street and the existing egress stairs on the eastern face on such building, or the permitted additions thereto, respectively, the Dyer Avenue Platform shall be open to the sky. - Required amenities
The Dyer Avenue Platform shall contain the following features and amenities which may be located on the portion of the Dyer Avenue Platform located within the easement provided pursuant to paragraph (b) of Section 93-72 (Public Access Areas at 450 West 33rd Street):- a minimum of 16 trees (or other amounts equivalent to a minimum of 64 caliper inches), of which a minimum of 12 trees (or other amounts equivalent to a minimum of 48 caliper inches) shall be located south of the center line of the prolongation of West 32nd Street;
- planting beds, which in the aggregate, occupy an area of at least 1500 square feet, of which a minimum of 450 square feet of planting beds shall be located south of the center line of the prolongation of West 32nd Street and a minimum of 250 square feet of planting beds shall be located within 30 feet of the southern street line of 33rd Street. No more than 25 percent of the linear feet of the planting beds shall have bounding walls exceeding 18 inches in height above an adjacent walking surface;
- a minimum of 350 linear feet of seating shall be provided, of which 50 percent shall consist of seats with backs and with at least 210 linear feet of seating located south of the center line of the prolongation of West 32nd Street and a minimum of 50 linear feet of seating located within 30 feet of the southern street line of West 33rd Street;
- the glazing requirements of paragraph (c) of Section 93-14 shall apply to the ground floor level of at least 70 percent of the length of all building walls fronting on the eastern edge of the Dyer Avenue Platform; and
- at least two pedestrian circulation paths with a minimum clear path of eight feet or one circulation path with a minimum clear path of 12 feet shall be provided along the full length of the Dyer Avenue Platform, from West 31st Street to West 33rd Street.
Vertical circulation elements, including stairs and ramps traversing the grade changes of the Dyer Avenue Platform shall be considered a part of the Dyer Avenue Platform and not an obstruction.
- Location and minimum dimensions
- West 31st Street Connector
- Location and minimum dimensions
A publicly accessible connection (hereinafter referred to as the "West 31st Street connector") shall be provided between the Dyer Avenue Platform required pursuant to paragraph (e) of this Section and West 31st Street, as shown on Map 1 in Appendix B. The West 31st Street connector shall be located on West 31st Street adjoining the eastern boundary of the Dyer Avenue Platform and shall have a minimum area of 450 square feet. - Required amenities
The West 31st Street connector shall be directly accessible from West 31st Street by a staircase with a minimum width of eight feet and by an elevator.
- Location and minimum dimensions
- Connection to below-grade passage
Where a pedestrian passage extending from the Eighth Avenue Subway beneath West 33rd Street to the west side of Ninth Avenue has been constructed, an entrance within the development shall be constructed that connects with such passage.
Public access areas on the Ninth Avenue Rail Yard provided pursuant to the requirements of Section 93-73, shall comply with the applicable design reference standards set forth in paragraph (a) and the maintenance provisions of paragraph (b) of this Section.
- Design reference standards
- seating shall meet the minimum and maximum dimensional standards set forth in paragraphs (1) through (7) of Section 37-741 (Seating), inclusive;
- where planting areas are provided, they shall meet the soil depth, continuous area, permeable surface and irrigation requirements of Section 37-742 (Planting and trees). Where trees are provided, they shall meet the planting standards, soil requirements and irrigation standards set forth in Section 37-742;
- steps shall meet the minimum dimensional standards set forth in Section 37-725 (Steps);
- kiosks or open air cafes shall meet the operational and service requirements listed in paragraphs (a) and (b) of Section 37-73 (Kiosks and Open Air Cafes) and shall not occupy in the aggregate more than 20 percent of the public access areas required by Section 93-73. Seating provided as part of an open air cafe shall not count towards meeting the seating requirements of a public access area listed in Section 93-73;
- the public access areas on the Ninth Avenue Rail Yard shall provide the following public signage system:
- One entry plaque in each of the following locations:
- entry to the Entry Plaza from West 33rd Street;
- entry to the Central Plaza from Ninth Avenue;
- entry to the Art Plaza from West 31st Street;
- sidewalk level entry to the West 31st Street Connector; and
- entry to the Dyer Avenue Platform from West 33rd Street.
- Each entry plaque is subject to the signage standards as set forth in paragraph (a)(1) through (a)(4) of Section 37-751 (Public space signage systems).
- Each entry plaque shall be mounted on a wall, a permanent free-standing post, or on a post located within a planter, with its center five feet above the elevation of the nearest walkable pavement. The maximum height of such free-standing post shall be six feet, with a maximum width and depth of 16 inches. Each entry plaque shall be in a position that clearly identifies the entry into the portion of the public access areas on the Ninth Avenue Rail Yard that such plaque is provided in connection with, and placed so that the entire entry plaque is obvious and directly visible, without any obstruction, along every line of sight from all paths of pedestrian access to that portion of the public access areas on the Ninth Avenue Rail Yard.
- A minimum of one information plaque, constructed from the same permanent materials as the entry plaques, or combined with one or more of the required entry plaques, shall be provided within the Art Plaza, the Entry Plaza, the Central Plaza and Dyer Avenue. The information plaque shall be mounted on a wall, a permanent free-standing post, or on a post located within a planter, with its center five feet above the elevation of the nearest walkable pavement. The maximum height of such free-standing post shall be six feet, with a maximum width and depth of 16 inches.
- Each information plaque is subject to the signage requirements as set forth in paragraphs (b)(1) through (b)(6) of Section 37-751 except that paragraph (b)(3) shall be modified to read, "in lettering three-eighths of an inch in height, the words: 'This public access area contains:'" followed by the total linear feet of seating, the type and quantity of trees and the number of additional required amenities, such as moveable seating, that are provided in the portion of the public access area in which the entry plaque or information plaque is provided.
- where buildings front on to public access areas, canopies, awnings, marquees and sun control devices shall be permitted pursuant to the standards set forth in paragraph (c) of Section 37-726 (Permitted obstructions);
- the aggregate number of litter receptacles in such public access areas shall be 21;
- no gates, fences or other barriers shall be permitted within such public access areas except that protective bollards provided in connection with the development of the Ninth Avenue Rail Yard may be located within the required public access areas; and
- for the purposes of applying the sign regulations to building walls facing public access areas, such public access areas shall be considered streets.
- Maintenance
The owner or owners shall be responsible for the maintenance of all public access areas, including, but not limited to, litter control, management of pigeons and rodents, maintenance of required lighting levels, and the care and replacement of furnishings and vegetation.
No certification for the phased development of public access areas on the Ninth Avenue Rail Yard shall be permitted until a plan has been submitted that provides for the completion of public access areas in accordance with the provisions of this Section. Such plan shall provide, at a minimum, that the entry plaza, required pursuant to paragraph (a) of Section 93-73 (Public Access Areas on the Ninth Avenue Rail Yard) will be provided in connection with the construction of a building located on the northeast corner of the Ninth Avenue Rail Yard, that the art plaza, required pursuant to paragraph (c) of Section 93-73, will be provided in connection with the construction of a building located on the southeast corner of the Ninth Avenue Rail Yard and that in connection with the construction of a building on the southwest corner of the Ninth Avenue Rail Yard, the West 31st Street connector required by paragraph (e) of Section 93-73, and a 20-foot wide paved area along the eastern edge of Dyer Avenue and extending for the north-south dimension of such building will be provided.
An application for certification under this Section shall be filed with the Chairperson of the City Planning Commission and such application shall include a site plan indicating the area and dimensions of the public access area, or portions thereof, and a detailed plan or plans demonstrating compliance with the requirements of Section 93-73.
Plans for the public access areas shall be set forth in an instrument in a form acceptable to the City, including such provisions as are necessary to ensure compliance with the provisions of this Section. Such instrument shall be filed and duly recorded in the Office of the City Register of the City of New York for New York County and indexed against the property. Such filing and recording of the instrument shall be a precondition for the Chairperson's certification to the Department of Buildings under this Section. The recording information shall be included on the certificate of occupancy for any building, or portion thereof, on the zoning lot issued after the recording date.
No temporary certificate of occupancy from the Department of Buildings may be issued for any portion of a development within a phase until the Chairperson of the City Planning Commission certifies to the Department of Buildings that the public access area, or portions thereof associated with such phase, is substantially complete and that such public access area, or portions thereof, are open to and useable by the public. No permanent certificate of occupancy from the Department of Buildings may be issued for any portion of such development until the Chairperson certifies to the Department of Buildings that the public access areas, or portions thereof, are fully complete, and that all requirements of this Section have been met in accordance with the plans for public access area, or portions thereof associated with such phase.
No temporary certificate of occupancy from the Department of Buildings may be issued for a building, or portion thereof, where the total amount of floor area that has been developed or enlarged on the Ninth Avenue Rail Yard exceeds 3,204,000 square feet until the Chairperson of the City Planning Commission certifies to the Commissioner of Buildings that the public access areas at 450 West 33rd Street required by paragraphs (c) and (d) of Section 93-72 and that all public access areas on the Ninth Avenue Rail Yard required by Section 93-73 have been substantially completed and are open and usable by the public. Notwithstanding the foregoing, the Chairperson may, with respect to the public access area required by paragraph (c) and the elevator required by paragraph (d) of Section 93-72 at 450 West 33rd Street, certify to the Commissioner of Buildings that such temporary certificate of occupancy may be issued absent their substantial completion provided that:
- the owner of 450 West 33rd Street has submitted proof that all or portions of the area of the West 31st Street passageway required by paragraph (c) of Section 93-72 was at any time subject to a lease with an expiration date of December 31, 2019, and was not able to obtain control of the areas subject to such lease on or before December 31, 2017;
- a letter of credit has been posted in accordance with City requirements, and such letter of credit:
- is in an amount equal to 200 percent of the estimated cost to construct the public access area and the elevator at 450 West 33rd Street, required by paragraphs (c) and (d) of Section 93-72, respectively, as set forth in a cost estimate prepared by a professional engineer. Such cost estimate shall be based upon construction documents prepared by a registered architect and submitted with the application for certification pursuant to this Section, and shall be subject to review and acceptance by the City; and
- authorizes the City to draw upon the letter of credit if such public access area and elevator have not been substantially completed and are not open and usable by the public by December 31, 2022;
- that an easement agreement has been recorded granting the City access to 450 West 33rd Street and the Ninth Avenue Rail Yard, as may be necessary for purposes of constructing the public access area and elevator required by paragraphs (c) and (d) of Section 93-72, respectively, if they are not completed by the owner by December 31, 2022; and
- in addition to the foregoing, such letter of credit shall be maintained from the date of certification for temporary certificates of occupancy, pursuant to this Section, until the Chairperson of the City Planning Commission certifies to the Commissioner of Buildings that the public access area required by paragraph (c) and the elevator required by paragraph (d) of Section 93-72 have been substantially completed and are open and usable by the public, or until same have been substantially completed by the City. The Chairperson may, no more frequently than annually, require the submission of an updated or new letter of credit in an amount that reflects changes in costs over time, and such updated or new letter of credit shall be subject to the requirements and procedures of paragraph (b) of this Section, until such letter of credit is released based upon substantial completion.
Notwithstanding the foregoing, in the event that a temporary public access area plan is approved pursuant to Section 93-734 (Certification to temporarily modify public access areas for construction staging), no temporary certificate of occupancy from the Department of Buildings may be issued for any portion of a development until the Chairperson certifies to the Department of Buildings that the public access area, or portions thereof associated with a phase of development, is substantially complete and in accordance with such temporary public access area plan, and the public access area, or portions thereof, are open and useable by the public. No permanent certificate of occupancy from the Department of Buildings may be issued for any portion of such development until the Chairperson certifies to the Department of Buildings that the public access area, or portions thereof associated with such phase, has been fully completed in accordance with the plan therefor, and that such public access area, or portions thereof, are open and useable by the public.
The Chairperson of the City Planning Commission may modify the general requirements of the public access areas listed in Section 93-73 (Public Access Areas on the Ninth Avenue Rail Yard), provided that the Chairperson certifies to the Commissioner of Buildings that such a change is necessary to accommodate unforeseen ventilation demands within the Ninth Avenue Rail Yard. In addition to the site plan required pursuant to Section 93-732 (Certification for public access areas on the Ninth Avenue Rail Yard), a mechanical plan shall be provided demonstrating the need to modify such general requirements.
In the event that the applicant demonstrates to the satisfaction of the Chairperson of the City Planning Commission that the area designated for public access will be required for construction staging or similar activities in a future phase of development, the application for the site plan approval may be accompanied by a request for approval of a temporary public area which may include fewer amenities and other features required pursuant to Section 93-73 (Public Access Areas on the Ninth Avenue Rail Yard), as necessary to accommodate such future construction staging or similar activities.
Such temporary public access area plan shall be subject to review and approval in the same manner as site plan approval pursuant to Section 93-732 (Certification for public access areas on the Ninth Avenue Rail Yard) and, if approved pursuant thereto, shall be implemented and remain in effect only for the period necessary to accommodate the need for use of the public access area for construction staging or similar activities in a future phase of development. Following the expiration of such period, the site plan shall be implemented.
The provisions of this Section shall apply to any development in the Pennsylvania Station Subarea B4 of the Farley Corridor Subdistrict B.
- Public space
A publicly accessible enclosed space with a minimum area of 32,500 square feet shall be provided. Such space shall have at least 100 feet of frontage along the Eighth Avenue street line, and have a minimum clear height of 60 feet. The length of such space shall not exceed four times its narrowest width. Up to one-half of such space may be below- grade but shall be visually connected to the at-grade space. Furthermore, such below-grade space shall be connected to the at-grade space by escalators on at least two sides. The retail and glazing requirements of Section 93-14 (Ground Floor Level Requirements) shall apply to least 70 percent of the length of all building walls facing each side of such space. Such space shall provide direct access to the through block connection required pursuant to paragraph (b) of this Section, adjacent building lobbies and transit facilities. - Through block connection
A through block connection shall be provided linking West 31st Street and West 33rd Street, at least 300 feet from Eighth Avenue and with direct access to the public space required pursuant to paragraph (a) of this Section. Such through block connection shall have a minimum clear width of 20 feet and may be open or enclosed. If enclosed, such through block connection shall have a minimum clear height of 30 feet. - Plaza
A publicly-accessible plaza, open to the sky, may be provided at the intersection of Eighth Avenue and West 31st Street. Such plaza shall have a minimum area of 12,000 square feet with a minimum frontage of 60 feet along West 31st Street, and be provided in accordance with the standards for public plazas set forth in Section 37-70, inclusive. - Corner circulation space
Corner circulation spaces shall be provided at the corners of Eighth Avenue and West 31st Street and Eighth Avenue and West 33rd Street. Such spaces shall comply with the requirements for corner circulation spaces of paragraph (d) of Section 37-53. Such spaces shall count towards meeting the pedestrian circulation space requirements of Section 93-63. However, no corner circulation space shall be required at the corner of Eighth Avenue and West 31st Street if a plaza is provided at such corner in accordance with paragraph (c) of this Section.
Public access areas in Subdistrict F shall be comprised of publicly accessible open spaces, private streets and pedestrian ways.
Publicly accessible open spaces are listed in this Section, inclusive. Such publicly accessible open spaces shall be comprised of the Western Open Space, the Central Open Space, the Southwest Open Space, the Northeast Plaza, the Midblock Connection, and the High Line<