Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard.
Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to the referenced national standards set forth herein in accordance with the exception contained in Section 28-103.19 of the Administrative Code.
The application of the referenced standards shall be as specified in Section 102.8.
AHRI Air-Conditioning, Heating & Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
 
Standard
reference
number
Title Referenced
in code
section number
1010— 02 Self-contained, Mechanically Refrigerated Drinking-Water Coolers
410.1
810—16
Addendum 1
Performance Rating of Automatic Commercial
Ice-makers

428.1.1

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
 
Standard
reference
number
Title Referenced
in code
section number
A118.10—99 Specifications for Load Bearing, Bonded, Waterproof Membranes for Thin Set Ceramic
Tile and Dimension Stone Installation
417.5.2.5,
417.5.2.6
Z4.3—95

Minimum Requirements for Nonsewered Waste-disposal Systems
311.1
Z21.22—99 (R2003) Relief Valves for Hot Water Supply Systems with Addenda Z21.22a—2000 (R2003) and
Z21.22b—2001 (R2003)
504.2, 504.4,
504.4.1
CSA B45.5—11/
IAPMO
Z124—11

Plastic Plumbing Fixtures



407.1, 415.1,
416.1, 416.2,
417.1, 418.1,
419.1, 420.1

API American Petroleum Institute
1220 L Street NW
Washington, DC 20005-4070
 
Standard
reference
number
Title Referenced
in code
section number
12D — 2008 Specification for Field Welded Tanks for Storage of Production Liquids, effective April 1, 2009 1302.7.2,
1303.10.2
12F — 2008

Specification for Shop Welded Tanks for Storage of Production Liquids, effective April 1, 2009 1302.7.2,
1303.10.2

ASCE/SEI American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston, VA 20191-4400
 
Standard
reference
number
Title Referenced
in code
section number
24 — 14 Flood Resistant Design and Construction 715.1, 1101.9.1

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
A112.1.2—2004

Air Gaps in Plumbing Systems

406.1, 409.2,
Table 608.1, 608.13.1
A112.1.3—2000 (R2011)

Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances
406.1, 409.2,
Table 608.1, 608.13.1
A112.3.1—2007 Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum Applications Above and Below Ground 412.1, Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, 1102.6, Table 1102.7
ASME
A112.3.4—2013/ CSA
B45.9—2013
Macerating Toilet Systems and Related Components





712.4.1
A112.4.1—2009 Water Heater Relief Valve Drain Tubes 504.6
A112.4.2—2009

Water Closet Personal Hygiene Devices


424.9
A112.4.3—1999 (R2010)

Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System



405.4
A112.4.14—2004 (R2010)

Manually Operated, Quarter-Turn Shutoff Valves for Use in Plumbing Systems

Table 605.7
A112.6.1M—1997 (R2008) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use
405.4.3
A112.6.2—2000 (R2010)

Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks
405.4.3
A112.6.3—2001 (R2007) Floor and Trench Drains


412.1
A112.6.4—2003 (R2008) Roof, Deck, and Balcony Drains


1102.6
A112.6.7—2010

Enameled and Epoxy-coated Cast-iron and PVC Plastic Sanitary Floor Sinks
427.1
A112.6.9—2005 (R2010) Siphonic Roof Drains


1107.1
A112.14.1—2003 Backwater Valves 715.2
A112.14.3—2000 Grease Interceptors 1003.3.4
A112.14.4—2001 (Reaffirmed 2007) Grease Removal Devices




1003.3.4
A112.18.1— 2012 /
CSA
B125.1—2012
Plumbing Supply Fittings



424.1, 424.2, 424.3, 424.4, 424.6, 424.8,
Table 605.7, 607.4, 608.2
A112.18.2—2011
/
CSA
B125.2—2011
Plumbing Waste Fittings






424.1.2
A112.18.3—2002 (Reaffirmed 2008) Performance Requirements for Backflow Protection Devices and Systems in Plumbing Fixture Fittings


424.2, 424.6
A112.18.6/
CSA
B125.6—2009
Flexible Water Connectors




605.6
A112.18.9—2011 Protectors/Insulators for Exposed Waste and Supplies on
Accessible Fixtures


404.3
A112.19.1—2013
/
CSA
B45.2—2013
Enameled Cast Iron and Enameled Steel Plumbing Fixtures



407.1, 410.1,
415.1, 416.1,
418.1
A112.19.2—2013
/
CSA B45.1—13
Ceramic Plumbing Fixtures 401.2, 405.9,
407.1, 408.1,
410.1, 415.1,
416.1, 417.1,
418.1, 419.1,
420.1
A112.19.3—
2008/
CSA
B45.4—08(R2013)
Stainless Steel Plumbing Fixtures




405.9, 407.1,
415.1, 416.1,
418.1, 420.1
A112.19.5—2011
/
CSA
B45.15—2011
Flush Valves and Spuds for Water-closets, Urinals, and Tanks





425.4
A112.19.7M—20
12/
CSA
B45.10—2012
Hydromassage Bathtub Systems






421.1, 421.4
A112.19.12—200
6



Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and Shampoo Bowl Carrier Systems and Drain Systems



416.4, 418.3
A112.19.14-2006(
R2011)
Six-Liter Water Closets Equipped with a Dual Flushing Device
420.1
A112.19.15—200
5
Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors 407.4, 421.6
A112.19.19—200
6
Vitreous China Nonwater Urinals 419.1
A112.21.3-1985(
R2007)
Hydrants for Utility and Maintenance Use Table 608.1,
608.13.6
A112.36.2M—19
91 (R2008)
Cleanouts


709.1.10.2
ASSE 1016/
ASME
A112.1016/
CSA
B125.16-f2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Individual Fixture Fittings




424.3, 424.4,
607.4
B1.20.1—1983(R
2006)





Pipe Threads, General Purpose (inch)






605.11.3,
605.13.4,
705.2.3, 705.3.3,
705.6.4,
705.9.1,
705.11.3,
803.3.4.1.3
B16.3—2011

Malleable Iron Threaded Fittings Classes 150 and 300 Table 702.4,
Table 1102.7
B16.4—2011

Gray Iron Threaded Fittings Classes 125 and 250 Table 605.5, Table 702.4, Table 1102.7
B16.12—2009

Cast-iron Threaded Drainage Fittings

Table 702.4,
Table 1102.7
B16.15—2011

Cast Bronze Threaded Fittings

Table 605.5,
Table 702.4
B16.18—2012

Cast Copper Alloy Solder Joint Pressure Fittings Table 605.5,
Table 702.4
B16.22—2001 (R2010) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings Table 605.5,
Table 702.4
B16.23—2011

Cast Copper Alloy Solder Joint Drainage Fittings (DWV)
Table 702.4
B16.26—2011

Cast Copper Alloy Fittings for Flared Copper Tubes Table 605.5,
Table 702.4
B16.29—2012


Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV)

Table 702.4
B31.9 — 2017 Building Services Piping 605.23.2
BPVC—2010 Boiler and Pressure Vessel Code 312.11.1, 501.2

ASPE American Society of Plumbing Engineers
8614 Catalpa Avenue, Suite 1007
Chicago, IL 60656-1116
 
Standard
reference
number
Title Referenced
in code
section number
45 — 2013 Siphonic Roof Drainage Systems 1107.1
ASSE American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake, OH 44145
 
Standard
reference
number
Title Referenced
in code
section number
1001—08

Performance Requirements for Atmospheric Type Vacuum Breakers 425.2, Table 608.1, 608.13.6, 608.16.4.1
1002—08 Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity Water Closet Flush Tanks 425.3.1, Table 608.1
1003—09

Performance Requirements for Water Pressure Reducing Valves
604.8
1004—08


Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines

409.1
1008—06

Performance Requirements for Plumbing Aspects of Food Waste Disposer Units
413.1
1010—04

Performance Requirements for Water Hammer Arresters 604.9
1011—04

Performance Requirements for Hose Connection Vacuum Breakers Table 608.1, 608.13.6
1012—09

Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent Table 608.1, 608.13.3, 608.16.2
1013—09 Performance Requirements for Reduced Pressure Principle Backflow Preventers and Reduced Pressure Fire Protection Principle Backflow Preventers Table 608.1, 608.13.2,
608.16.2
1015—09 Performance Requirements for Double Check Backflow Prevention Assemblies and
Double Check Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.13.7
ASSE 1016/
ASME
A112.1016/
CSA
B125.16—2011
Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings






424.3, 424.4, 607.4, 613.1
1017—2010


Performance Requirements for Temperature Actuated Mixing Valves for Hot Water Distribution System

501.2.3, 613.1
1018—2010

Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied 1002.4.1.1,
1002.4.1.2
1019—2010


Performance Requirements for Vacuum Breaker Wall Hydrants, Freeze Resistant, Automatic Draining Type
Table 608.1, 608.13.6
1020—04

Performance Requirements for Pressure Vacuum Breaker Assembly Table 608.1, 608.13.5
1022—03


Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment

Table 608.1, 608.16.1, 608.16.10
1024—04


Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets)
Table 608.1
608.13.10
1035—08

Performance Requirements for Laboratory Faucet Backflow Preventers Table 608.1, 608.13.6
1037—90

Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures
425.2
1047—2009


Performance Requirements for Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.13.2
1048—2009


Performance Requirements for Double Check Detector Fire Protection Backflow Prevention Assemblies
Table 608.1, 608.13.7
1052—04

Performance Requirements for Hose Connection Backflow Preventers Table 608.1, 608.13.6
1055—2009

Performance Requirements for Chemical Dispensing Systems
608.13.9
1056—2010


Performance Requirements for Spill Resistant Vacuum Breaker

Table 608.1,
608.13.5,
608.13.8
1060—2006

Performance Requirements for Outdoor Enclosures for Fluid Conveying Components
608.14.1
1061—2010

Performance Requirements for Removable and Nonremovable Push Fit Fittings Table 605.5, 605.14.4
1062—2006


Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Supply Fittings

424.7
1066—2009


Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings

604.11
1069—05

Performance Requirements for Automatic Temperature Control Mixing Valves
424.4
1070—04


Performance Requirements for Water-temperature Limiting Devices

408.3, 416.5, 423.3, 424.5,
607.1.2
1079—2005

Performance Requirements for Dielectric Pipe Unions 605.24.1, 605.24.3
5013—2009



Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and Reduced Pressure Fire Protection Backflow Preventers (RFP)


312.10.2
5015—2009



Performance Requirements for Testing Double Check Valve Backflow Prevention Assemblies (DC) and Double Check Fire Protection Backflow Prevention Assemblies (DCF)


312.10.2
5020—2009

Performance Requirements for Testing Pressure Vacuum Breaker Assemblies (PVBA)
312.10.2
5047—98


Performance Requirements for Testing Reduced Pressure Detector Fire Protection Backflow Prevention Assemblies (RPDA)

312.10.2
5048—2009

Performance Requirements for Testing Double Check Valve Detector Assembly (DCDA)
312.10.2
5052—98

Performance Requirements for Testing Hose Connection Backflow Preventers
312.10.2
5056—98

Performance Requirements for Testing Spill Resistant Vacuum Breaker (SRVB)
312.10.2

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
 
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—12


Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless Table 702.1,
Table 702.3,
Table 1102.4
A 74—13A



Specification for Cast- iron Soil Pipe and Fittings


Table 702.1, Table 702.2,
Table 702.3,Table 702.4,
708.1.6, Table 1102.4,
Table 1102.5, Table 1102.7
A 123 — 12


Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
Table 702.3,
Table 1102.4
A 153/A 153M—16a

Specifications for Zinc Coating (Hot Dip) on Iron and Steel Hardware
Table 702.4
Table 1102.7
A 312/A 312M—13


Specification for Seamless, Welded, And Heavily Cold Worked Austenitic Stainless Steel Pipes Table 605.4,
Table 605.4.1,
Table 605.5,
Table 1301.6
A 403/A 403M—11

Specification for Wrought Austenitic Stainless Steel Piping Fittings
Table 605.5,
Table 605.8
A 518/A 518M—99 (2012)

Standard Specification for Corrosion-Resistant High-Silicon Iron Castings

Table 803.3.1
A 778—01(2009)e1


Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products

Table 605.4,
Table 605.4.1,
Table 605.5
Table 1301.6
A 861—04 (2017)

Standard Specification for High-Silicon Iron Pipe and Fittings Table 803.3.2
A 888—13A



Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and Vent Piping Application Table 702.1, Table 702.2,
Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
B 32—08 Specification for Solder Metal 605.14.6, 705.6.3, 705.7.3
B 42—10

Specification for Seamless Copper Pipe, Standard Sizes Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6
B 43—09

Specification for Seamless Red Brass Pipe, Standard Sizes Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6
B 62—17

Specification for Composition Bronze or Ounce Metal Castings Table 605.5, Table 702.4, Table 1102.7
B 75—11



Specification for Seamless Copper Tube


Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3, Table 1102.4,
Table 1102.7, Table 1301.6
B 88—09





Specification for Seamless Copper Water Tube




Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3, Table 1102.4,
Table 1102.7, Table 1301.6,
Figure E103.3(2),
Figure E103.3(3)
B 152/B 152M—13 Specification for Copper Sheet, Strip Plate and Rolled Bar 402.3, 417.5.2.4 425.3.3, 902.2
B 251—10




Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube

Table 605.3,Table 605.4, Table 605.4.1, Table 702.1, Table 702.2, Table 702.3,
Table 1102.4, Table 1102.7,
Table 1301.6
B 302—12

Specification for Threadless Copper Pipe, Standard Sizes Table 605.4, Table 605.4.1, Table 702.1, Table 1301.6
B 447—12a

Specification for Welded Copper Tube Table 605.4, Table 605.4.1, Table 1301.6
B 687— (2011)

Specification for Brass, Copper, and Chromium-plated Pipe Nipples
Table 605.8
B 813—10


Specification for Liquid and Paste Fluxes for Soldering of
Copper and Copper Alloy Tube


605.14.6, 705.6.3, 705.7.3
B 828—02(2010)


Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings

605.14.6, 705.6.3, 705.7.3
C 4—04(2009)

Specification for Clay Drain Tile and Perforated Clay Drain Tile Table 702.3, Table 1102.4, Table 1102.5
C 14—11


Specification for Nonreinforced Concrete Sewer, Storm Drain, and Culvert Pipe
Table 702.3,
Table 1102.4
C 76—13a

Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Table 702.3, Table 1102.4
C 425—04(2009)

Specification for Compression Joints for Vitrified Clay Pipe and Fittings Table 702.4, 705.12, 705.16, Table 1102.7
C 443—12


Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets

705.5, 705.16
C 564—12

Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings
705.4.2, 705.4.3, 705.16
C 654—15

Standard Specification for Porous Concrete Pipe
Table 1102.5
C 700—13


Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated
Table 702.3, Table 702.4, Table 1102.4, Table 1102.5
C 1053—00 (2010)

Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications
Table 803.3.1,
Table 803.3.4
C 1173—10e1


Specification for Flexible Transition Couplings for Underground Piping System
705.2.1, 705.5, 705.11.1, 705.12, 705.13.2, 705.16
C 1277—12


Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings

705.4.3
C 1440—08



Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV), Sewer, Sanitary and Storm Plumbing Systems


705.16
C 1460—08


Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground

705.16
C 1461—08




Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain, Waste and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use



705.16
C 1540—11


Specifications for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings

705.4.3
C 1563—13



Standard Test Method for Gaskets for Use in
Connection with Hub and Spigot Cast Iron Soil Pipe and Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications



705.4.2
D 1586—11


Standard Test Method for Standard Penetration Test (SPT) and Split-barrel Sampling of Soils

1114.2.1
D 1587—15

Standard Practice for Thin-walled Tube Sampling of Soils for Geotechnical Purposes
1114.2.1
D 2235—04(2011)

Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings

705.2.2
D 2464—15


Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

Table 1102.7
D 2466—17

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40
Table 1102.7
D 2467—15

Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Table 1102.7
D 2564—12

Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems
705.11.2
D 2657—07


Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Waste, and Vent Pipe and Fittings
705.13.1, Table
1102.7
D 2661—11


Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings Table 702.1, Table 702.4, 705.2.2,
Table 1102.7
D 2665—12




Specification for Poly (Vinyl Chloride) (PVC)
Plastic Drain, Waste, and Vent Pipe and Fittings


Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.7, Table 1403.2.1
D 2729—11

Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 1102.5
Table 1403.2
D 2751—05

Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings Table 702.4
Table 1102.7
D 2846—09be1


Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems

Table 1301.6
D 2855—96 (2010)

Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings

705.11.2
D 2949—10


Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings Table 702.1,
Table 702.4
Table 1403.2.1
D 3034—08




Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings



Table 702.3, 702.4, Table 1102.4
Table 1102.5,
Table 1102.7,
Table 1403.2.1
D 3212—07


Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals 705.2.1,
705.11.1,
705.13.2
D 3311—11

Specification for Drain, Waste and Vent (DWV) Plastic Fittings Patterns
Table 1102.7
D 3350—14

Specification for High Density Polyethylene Pipe (HPDE) Table 1102.4,
Table 1102.7
D 4068—09


Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane

417.5.2.2
D 4551—12


Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane

417.5.2.1
F 405—05


Specification for Corrugated Polyethylene (PE) Pipe and Fittings

Table 1102.
Table 1403.2,
Table 1403.2.1
F 409—12


Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings

424.1.2
F 437—15



Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 702.3,
Table 702.4,
Table 1102.4,
Table 1102.7
F 438—17



Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40

Table 702.3,
Table 702.4,
Table 1102.4,
Table 1102.7
F 439—13



Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

Table 702.3,
Table 702.4,
Table 1102.4,
Table 1102.7
F 477—10

Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
705.16
F 628—08


Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core Table 702.1,
Table 702.4, 705.2.2,
Table 1102.7
F 656—10


Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings

705.11.2
F 891—10



Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core

Table 702.1, Table 702.2, Table 702.3, Table 1102.4, Table 1102.5
F 1412—09





Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage




Table 702.2,
Table 803.3.1,
Table 803.3.2,
803.3.4.4.1,
803.3.4.5.1,
Table 1102.7
F 1488—09e1

Specification for Coextruded Composite Pipe Table 702.1, Table 702.2, Table 1403.2
F 1673—10



Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems


Table 803.3.1,
Table 803.3.2,
803.3.4.6.1,
Table 1102.7
F 1866—07


Specification for Poly (Vinyl Chloride) (PVC)
Plastic Schedule 40 Drainage and DWV
Fabricated Fittings

Table 702.4, Table 1102.7, Table 1403.2.1
F 2306/F 2306M—13 12'' to 60'' Annular Corrugated Profile-wall
Polyethylene (PE) Pipe and Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications
Table 702.4,
Table 1102.7
F 2389—10



Specification for Pressure-rated Polypropylene (PP) Piping Systems



Table 1301.6,
Table 1403.2,
Table 1403.2.1
F 2618—15



Standard Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Fittings for Chemical Waste Drainage Systems


Table 803.3.1,
Table 803.3.2,
803.3.4.1.2
F 2764—17e1


Standard Specification for 6 to 60 in. [150 to 1500 mm] Polypropylene (PP) Corrugated Double and Triple Wall Pipe

Table 1102.5
F 3219—17


Standard Specification for 3 to 30 in. (75 To 750 mm) Polypropylene (PP) Corrugated Single Wall Pipe and Fittings

Table 1102.5

AWS American Welding Society
8669 NW 36 Street, #130
Doral, FL 33166
 
Standard
reference
number
Title Referenced
in code
section number
A5.8 M/A5.8—2011 Specifications for Filler Metals for Brazing and Braze Welding 605.11.1, 605.13.1,
605.14.1, 705.3.1, 705.6.1, 705.7.1

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
 
Standard
reference
number
Title Referenced
in code
section number
C110/A21.10—12

Ductile-iron and Gray-iron Fittings Table 605.5, Table 702.4, Table 1102.7
C111/A21.11-12

Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings 605.12
C115/A21.15—11


Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges
Table 605.4,
Table 605.4.1
C151/A21.51—02




Standard for Ductile-iron Pipe, Centrifugally Cast for Water



Table 605.4,
Table 605.4.1,
Table 702.1, Table 702.2.
Table 702.3,
Table 1102.4
C153—00/A21.53—11 Ductile-iron Compact Fittings for Water Service
Table 605.5
C500—09

Standard for Metal-Seated Gate Valves for Water Supply Service
Table 605.7
C504—10

Standard for Rubber-Seated Butterfly Valves
Table 605.7
C507—11

Standard for Ball Valves, 6 In. Through 60 In
Table 605.7
C510—07

Double Check Valve Backflow Prevention Assembly Table 608.1,
608.13.7
C511—07

Reduced-pressure Principle Backflow Prevention Assembly Table 608.1,608.13.2, 608.16.2
C651—05 Disinfecting Water Mains 610.1
C652—11 Disinfection of Water-storage Facilities 610.1
D100 — 2005

Standard for Welded Carbon Steel Tanks for Water Storage 1302.7.2,
1303.10.2
D115 — 2006 Standard for Tendon Prestressed-Concrete Water Tanks 1302.7.2,
1303.10.2
D120 — 2009 Standard for Thermosetting Fiberglass Reinforced Plastic Tanks 1302.7.2,
1303.10.2

CISPI Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
 
Standard
reference
number
Title Referenced
in code
section number
301—04a




Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping
Applications
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
310—11 Specification for Coupling for Use in Connection with Hubless Cast-iron Soil Pipe and Fittings for Sanitary
and Storm Drain, Waste and Vent Piping Applications
308.5.1, 308.6.1,
705.4.3

CSA CSA Group
8501 East Pleasant Valley
Cleveland, OH 44131-5516
 
Standard
reference
number
Title Referenced
in code
section number
A257.1M—2009

Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3,
Table 1102.4
A257.2M—2009


Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings
Table 702.3,
Table 1102.4
A257.3M—2009


Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections and Fittings Using Rubber Gaskets

705.5, 705.16
ASME
A112.3.4—2013/
CSA B45.9—2013
Macerating Systems and Related Components



712.4.1
ASME
A112.18.1—2012/
CSA B125.1—2012

Plumbing Supply Fittings




424.1, 424.2,
424.3, 424.4,
424.6, 424.8,
Table 605.7,
607.4, 608.2
ASME
A112.18.2—2011/
CSA B125.2—2011
Plumbing Waste Fittings






424.1.2
ASME
A112.19.1—2013/
CSA B45.2—2013
Enameled Cast-iron and Enameled Steel Plumbing Fixtures

407.1, 410.1,
415.1, 416.1,
418.1
ASME
A112.19.2—2013/
CSA B45.1—2013



Ceramic Plumbing Fixtures





401.2, 405.9,
407.1, 408.1,
410.1, 415.1,
416.1, 417.1,
418.1, 419.1,
420.1
ASME
A112.19.3—2008/
CSA
B45.4—08(R2013)
Stainless-steel Plumbing Fixtures




 405.9, 407.1,
415.1, 416.1,
418.1, 420.1
ASME
A112.19.5—2011/
CSA B45.15—2011
Flush Valves and Spuds for Water-closets, Urinals and Tanks





425.4
ASME
A112.19.7—2012/
CSA B45.10—2012
Hydromassage Bathtub Systems






421.1, 421.4
ASSE 1016/
ASME A112.1016/
CSA
B125.16—2011
Performance Requirements for Individual Thermostatic,
Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings




424.3, 424.4,
607.4
CSA B45.5—11/
IAPMO Z124-2011
Plastic Plumbing Fixtures



407.1, 415.1,
416.1, 416.2,
417.1, 418.1,
419.1, 420.1
B64.1.1—11



Vacuum Breakers, Atmospheric Type (AVB)


425.2, Table
608.1,
608.13.6,
608.16.4.1
B64.1.3—11

Spill Resistant Pressure Vacuum Breaks (SRPVB)
608.13.8
B64.2—11

Vacuum Breakers, Hose Connection Type (HCVB) Table 608.1,
608.13.6
B64.2.1—11 Vacuum Breakers, Hose Connection (HCVB) with Manual Draining Feature Table 608.1,
608.13.6
B64.2.1.1—11

Hose Connection Dual Check Vacuum Breakers, (HCDVB) Table 608.1,
608.13.6
B64.2.2—11

Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature Table 608.1,
608.13.6
B64.3—11


Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP)

Table 608.1,
608.13.3,
608.16.2
B64.4—11

Backflow Preventers, Reduced Pressure Principle Type (RP) Table 608.1,
608.13.2
B64.4.1—11


Reduced Pressure Principle for Fire Sprinklers (RPF)


Table 608.1,
608.13.2
B64.5—11

Double Check Backflow Preventers (DCVA)

Table 608.1,
608.13.7
B64.5.1—11

Double Check Valve Backflow Preventer for Fire Systems (DCVAF) Table 608.1
608.13.7
B64.6—11

Dual Check Backflow Preventers Valve (DuC) Table 608.1,
608.13.10
B64.7—11

Laboratory Faucet Vacuum Breakers (LFVB)

Table 608.1,
608.13.6
B64.10—11

Manual for the Selection and Installation of Backflow Prevention Devices 312.10.2
B64.10.1—11

Maintenance and Field Testing of Backflow Preventers 312.10.2
B79— 08(R2013) Commercial and Residential Drains, and Cleanouts 412.1
B125.3—2012



Plumbing Fittings



408.3, 423.3,
424.4, 424.5,
425.2, 425.3.1,
Table 605.7
B137.2—02

PVC Injection-Moulded Gasketed Fittings for Pressure Applications
Table 1102.7
B137.3—13

Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications
705.11.2
B181.1—11



Acrylonitrile-butadiene-styrene ABS Drain, Waste and Vent Pipe and Pipe Fittings


Table 702.1,
Table 702.4,
705.2.2, 715.2,
Table 1102.7
B181.2—11




Polyvinylchloride PVC and chlorinated
polyvinylchloride (CPVC) Drain, Waste, and Vent Pipe and Pipe Fittings


Table 702.1, Table 702.2,
Table 702.3, 705.11.2,
715.2, Table 1102.4
B181.3—11



Polyolefin and Polyvinylidene Fluoride (PVDF) Laboratory Drainage Systems


Table 803.3.1,
Table 803.3.2,
803.3.4.4.1,
Table 1102.7
B182.1—11


Plastic Drain and Sewer Pipe and Pipe Fittings



705.11.2, Table 1102.5
B182.2—11


PSM Type Polyvinylchloride PVC Sewer Pipe and Fittings

Table 702.3,
Table 1102.4,
Table 1102.5
B182.4—11


Profile Polyvinylchloride PVC Sewer Pipe and Fittings

Table 702.3,
Table 1102.4,
Table 1102.5
B182.6—11

Profile Polyethylene (PE) Sewer Pipe and Fittings for Leak-proof Sewer Applications
Table 1102.5
B182.8—11

Profile Polyethylene (PE) Storm Sewer and Drainage Pipe and Fittings
Table 1102.5
B356—10

Water Pressure Reducing Valves for Domestic Water Systems
604.8
B483.1—14 Drinking Water Treatment Units 611.1, 611.2
B602—10



Mechanical Couplings for Drain, Waste and Vent Pipe and Sewer Pipe


705.2.1, 705.4.3, 705.5, 705.11.1,
705.12, 705.13.2,
705.16

IAPMO IAPMO Group
4755 E. Philadelphia
Ontario, CA 91761
 
Standard
reference
number
Title Referenced
in code
section number
PS 117—08

Copper and Copper Allow Tubing System
Incorporating Press-type or Nail-type Connections
605.14.4
CSA B45.5—11/
IAPMO Z124-2011


Plastic Plumbing Fixtures



407.1, 415.1,
416.1, 416.2,
417.1, 418.1,
419.1, 420.1

ICC International Code Council, Inc.
500 New Jersey Ave. NW
6th Floor 
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
A117.1—2009 Accessible and Usable Buildings and Facilities 404.2, 410.1

ISEA International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington, VA 22209
 
Standard
reference
number
Title Referenced
in code
section number
ANSI/ISEA
Z358.1—2009
Emergency Eyewash and Shower Equipment

411.1


MSS Manufacturers Standardization Society Of the Valve and Fittings Industry, Inc.
127 Park St. NE
Vienna, VA 22180-4602
 
Standard
reference
number
Title Referenced
in code
section number
SP-67—2011 Butterfly Valves


Table 605.7
SP-70—2011 Gray Iron Gate Valves, Flanged and Threaded Ends


Table 605.7
SP-71—2011 Gray Iron Swing Check Valves, Flanged and Threaded
Ends

Table 605.7
SP-72—2010 Ball Valves with Flanged or Butt-Welding Ends for
General Service

Table 605.7
SP-78—2011 Cast Iron Plug Valves, Flanged and Threaded Ends


Table 605.7
SP-80—2008 Bronze Gate, Globe, Angle and Check Valves


Table 605.7
SP-110—2010 Ball Valves, Threaded, Socket Welded, Solder Joint,
Grooved and Flared Ends

Table 605.7

NFPA National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
 
Standard
reference
number
Title Referenced
in code
section number
51—13

Design and Installation of Oxygen-fuel Gas Systems for
Welding, Cutting and Allied Processes
1201.1, 1203.1
55—13 Compressed Gases and Cryogenic Fluids Code 1201.1, 1203.1
99—15 Health Care Facilities Code 1201.1, 1202.1

NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
 
Standard
reference
number
Title Referenced
in code
section number
3—2010 Commercial Warewashing Equipment 409.1
14—2011

Plastic Piping System Components and Related Materials
303.3, 611.3
18—2012

Manual Food and Beverage Dispensing Equipment
426.1
42—2011

Drinking Water Treatment Units-Aesthetic Effects
611.1, 611.3
44—2012

Residential Cation Exchange Water Softeners
611.1, 611.3
53—2011a Drinking Water Treatment Units—Health Effects 611.1, 611.3
58—2012 Reverse Osmosis Drinking Water Treatment Systems 611.2, 611.3
61—2012



Drinking Water System Components—Health Effects



410.1, 424.1,
605.4, 605.4.1,
605.5, 605.7,
606.5.4.2, 611.3
62—2012 Drinking Water Distillation Systems 611.1
372—2010 Drinking Water System Components — Lead Content 605.2

PDI Plumbing and Drainage Institute
800 Turnpike Street, Suite 300
North Andover, MA 01845
 
Standard
reference
number
Title Referenced
in code
section number
G101 (2012) Testing and Rating Procedure for Grease Interceptors
with Appendix of Sizing and Installation Data
1003.3.4

UL UL LLC
333 Pfingsten Road
Northbrook, IL 60062-2096
 
Standard
reference
number
Title Referenced
in code
section number
58 — 1996


Steel Underground Tanks for Flammable and
Combustible Liquids-with revisions through July 27,
1998

1302.7.2,
1303.10.2
142 — 2006


Steel Aboveground Tanks for Flammable and
Combustible Liquids-with revisions through
February 12, 2010

1302.7.2,
1303.10.2
174—2004

Household Electric Storage Tank Water Heaters—with
revisions through September 2012

502.1
430—2009

Waste Disposers—with revisions through March 23,
2011

413.1
732—1995

Oil-fired Storage Tank Water Heaters—with revisions
through April 2010

502.1
921—2004 Integral gas fired heating commercial dishwashers 409.1
1316 — 1994



Glass-Fiber Reinforced Plastic Underground Storage
Tanks for Petrolium Products, Alcohols and Alcohol
Gasoline Mixtures-with revisions through May 12,
2006


1302.7.2,
1303.10.2
1453—2004

Electric Booster and Commercial Storage Tank Water
Heaters—with revisions through July 2011

502.1
1746 — 2007

External Corrosion Protection Systems for Steel
Underground Storage Tanks
1302.7.2,
1303.10.2
1795—2009

Hydromassage Bathtubs including revisions through
August 23, 2011

421.1

WaterSense WaterSense U.S. Environmental Protection Agency Office of Wastewater Management (4204M)
1200 Pennsylvania Avenue, N.W.
Washington, D.C. 20460
 
Standard
reference
number
Title Referenced
in code
section number
v.1.0—October 1, 2009

High-efficiency Lavatory Faucet Specifications
604.4.1
v.1.0—October 8, 2009

WaterSense Specification for Flushing Urinals
604.4.1
v.1.0—December 17, 2015

WaterSense Specification for Flushometer-Valve Water Closets
604.4.1
v.1.1—July 26, 2018

WaterSense Specification for Showerheads
604.4.1
v.1.2—June 2, 2014 WaterSense Specification for Tank-Type Toilets
604.4.1
Linked Resources
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Code Compare
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Bookmarks
P
P Premium Feature

This feature is included in the premium subscription. Visit the feature page to learn more.

Learn More
Amendment Styling
P
Amendment styling is not available for this code.