Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title and the section or sections of this document that reference the standard.
Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to the referenced national standards set forth herein in accordance with the exception contained in Section 28-103.19 of the Administrative Code.
The application of the referenced standards shall be as specified in Section 102.8.
ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
Standard
reference
number
Title Referenced
in code
section number
A118.10—99 Specifications for Load Bearing, Bonded, Waterproof, Membranes for Thin Set Ceramic Tile
and Dimension Stone Installation
417.5.2.5
Z4.3—95 Minimum Requirements for Nonsewered Waste-Disposal Systems 311.1
Z21.22—99 (R2003) Relief Valves for Hot Water Supply Systems with Addenda Z21.22a-2000 (2003) and
Z21.22b-2001 (2003)
504.2, 504.4
Z124.1—95 Plastic Bathtub Units 407.1
Z124.2—95 Plastic Shower Receptors and Shower Stalls 417.1
Z124.3—95 Plastic Lavatories 416.1, 416.2
Z124.4—96 Plastic Water Closet Bowls and Tanks 420.1
Z124.6—97 Plastic Sinks 415.1, 418.1
Z124.9—94 Plastic Urinal Fixtures 419.1

ARI Air-Conditioning, Heating & Refrigeration Institute
4100 North Fairfax Drive, Suite 200
Arlington, VA 22203
Standard
reference
number
Title Referenced
in code
section number
1010— 02 Self-contained, Mechanically-refrigerated Drinking-water Coolers 410.1
810—06 Standard Rating Conditions 428.1.1

ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Standard
reference
number
Title Referenced
in code
section number
A112.1.2—2004 Air Gaps in Plumbing Systems Table 608.1, 608.13.1
A112.1.3—2000 (R2005) Air Gap Fittings for Use with Plumbing Fixtures, Appliances and Appurtenances Table 608.1, 608.13.1
A112.3.1—2007 Stainless Steel Drainage Systems for Sanitary, DWV, Storm and Vacuum
Applications Above and Below Ground
412.1, Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.2, Table 1102.4, Table 1102.5, 1102.6, Table 1102.7
A112.3.4—2000 (R2004) Macerating Toilet Systems and Related Components 712.4.1
A112.4.1—1993 (R2002) Water Heater Relief Valve Drain Tubes 504.6
A112.4.3—1999 (R2004) Plastic Fittings for Connecting Water Closets to the Sanitary Drainage System 405.4
A112.6.1M—1997 (R2002) Floor-affixed Supports for Off-the-floor Plumbing Fixtures for Public Use 405.4.3
A112.6.2—2000 (R2004) Framing-affixed Supports for Off-the-floor Water Closets with Concealed Tanks 405.4.3
A112.6.3—2001 (R2007) Floor and Trench Drains 412.1
A112.6.7—2001 (R2007) Enameled and Epoxy-coated Cast-iron and PVC plastic Sanitary Floor Sinks 427.1
A112.14.1—2003 Backwater Valves 715.2
A112.14.3—2000 Grease Interceptors 1003.3.4
A112.14.4—2001 (R2007) Grease Removal Devices 1003.3.4
A112.18.1— 2005 Plumbing Supply Fittings 424.1, 424.2, 424.3, 607.4, 608.2
A112.18.2—2005 Plumbing Waste Fittings 424.1.2
A112.18.3—2002 (R2008) Performance Requirements for Backflow Protection Devices and Systems 424.2, 424.6
A112.18.7—1999 (R2004) Deck mounted Bath/Shower Transfer Valves with Integral Backflow Protection 424.8
A112.19.1M—2004 (R2004) Enameled Cast Iron Plumbing Fixtures 407.1, 410.1, 415.1, 416.1, 418.1
A112.19.2M—2003 Vitreous China Plumbing Fixtures and Hydraulic Requirements for Water Closets
and Urinals
401.2, 405.9, 408.1,410.1, 416.1, 418.1, 419.1, 420.1
A1 12.19.3M—2000 (R2007) Stainless Steel Plumbing Fixtures (Designed for Residential Use) 405.9, 415.1, 416.1, 418.1
A112.19.4M—1994 (R2004) Porcelain Enameled Formed Steel Plumbing Fixtures 407.1, 416.1, 418.1
A112.19.5—2005 Trim for Water-closet Bowls, Tanks, and Urinals 425.4
A112.19.6—1995 Hydraulic Performance Requirements for Water Closets and Urinals 419.1, 420.1
A112.19.7M—2006 Hydromassage Bathtub Appliances 421.1
A112.19.8M—2007 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs, and
Whirlpool Bathtub Appliances.
421.4
A112.19.9M—1991 (R2002) Nonvitreous Ceramic Plumbing Fixtures with 2002
Supplement
407.1, 408.1, 410.1, 415.1, 416.1, 417.1, 418.1, 420.1
A112.19.12—2006 Wall Mounted and Pedestal Mounted, Adjustable, Elevating, Tilting and Pivoting Lavatory, Sink and
Shampoo Bowl Carrier Systems and Drain System
416.4, 418.3
A112.19.13—2001 (R2007) Electrohydraulic Water Closets 420.1
A112.19.15—2005 Bathtub/Whirlpool Bathtubs with Pressure Sealed Doors 407.4, 421.6
A112.21.2M—1983 Roof Drains 1102.6
A112.36.2M—1991 (R2002) Cleanouts 708.2
B1.20.1—1983 (R2006) Pipe Threads, General Purpose (inch) 605.12.3, 605.14.4, 705.2.3, 705.4.3, 705.9.4, 705.12.1, 705.14.3
B16.3—2006 Malleable Iron Threaded Fittings Classes 150 and 300 Table 702.4, Table 1102.7
B16.4—2006 Gray Iron Threaded Fittings Classes 125 and 250 Table 605.5, Table 702.4, Table 1102.7
B16.9—2003 Factory-made Wrought Steel Buttwelding Fittings Table 1102.7
B16.11—2005 Forged Fittings, Socket-welding and Threaded Table 1102.7
B16.12—1998 (R2006) Cast-iron Threaded Drainage Fittings Table 605.5, Table 702.4, Table 1102.7
B16.15—2006 Cast Bronze Threaded Fittings Table 605.5, Table 702.4
B16.18—2001 (R2005) Cast Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4
B16.22—2001 (R2005) Wrought Copper and Copper Alloy Solder Joint Pressure Fittings Table 605.5, Table 702.4
B16.23—2002 (R2006) Cast Copper Alloy Solder Joint Drainage Fittings (DWV) Table 605.5, Table 702.4
B16.26—2006 Cast Copper Alloy Fittings for Flared Copper Tubes Table 605.5, Table 702.4
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 1102.7
B16.29—2001 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings (DWV) Table 605.5, Table 702.4

ASSE American Society of Sanitary Engineering
901 Canterbury Road, Suite A
Westlake, OH 44145
Standard
reference
number
Title Referenced
in code
section number
1001—02 Performance Requirements for Atmospheric Type Vacuum Breakers 425.2, Table 608.1, 608.13.6, 608.16.4.1
1002—99 Performance Requirements for Antisiphon Fill Valves (Ballcocks) for Gravity
Water Closet Flush Tanks
425.3.1, Table 608.1
1003—01 Performance Requirements for Water-pressure Reducing Valves 604.8
1004—90 Performance Requirements for Backflow Prevention Requirements for Commercial Dishwashing Machines 409.1
1005—99 Performance Requirements for Water Heater Drain Valves 501.3
1006—89 Performance Requirements for Residential-Use Dishwashers 409.1
1007—92 Performance Requirements for Home-Laundry Equipment 406.1, 406.2
1008—89 Performance Requirements for Household Food Waste Disposer Units 413.1
1010—04 Performance Requirements for Water Hammer Arresters 604.9
1011—04 Performance Requirements for Hose Connection Vacuum Breakers Table 608.1, 608.13.6
1012—02 Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent Table 608.1, 608.13.3, 608.16.2
1013—05 Performance Requirements for Reduced-Pressure Principle Backflow Preventers and
Reduced-Pressure Fire Protection Principle Backflow Preventers
Table 608.1, 608.13.2, 608.16.2
1015—05 Performance Requirements for Double Check Backflow Prevention Assemblies and
Double Check Fire Protection Backflow Prevention Assemblies
Table608.1, 608.13.7
1016—96 Performance Requirements for Individual Thermostatic, Pressure Balancing and
Combination Control Valves for Individual Fixture Fittings
416.5, 424.3, 424.4, 424.5, 607.4, 613.1
1017—03 Performance Requirements for Temperature-Actuated Mixing Valves for Hot Water Distribution System 501.2, 613.1
1018—01 Performance Requirements for Trap Seal Primer Valves; Potable Water Supplied 1002.4
1019—04 Performance Requirements for Vacuum Breaker Wall Hydrants,
Freeze Resistant, Automatic Draining Type
Table 608.1, 608.13.6
1020—04 Performance Requirements for Pressure Vacuum Breaker Assembly Table 608.1, 608.13.5
1022—03 Performance Requirements for Backflow Preventer for Beverage Dispensing Equipment Table 608.1, 608.16.1, 608.16.10
1024—04 Performance Requirements for Dual Check Valve Type Backflow Preventers
(for Residential Supply Service or Individual Outlets)
Table 608.1
1035—02 Performance Requirements for Laboratory Faucet Backflow Preventers Table 608.1, 608.13.6
1037—90 Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures 425.2
1044—01 Performance Requirements for Trap Seal Primer Devices Drainage Types and Electronic Design Types 1002.4
1047—05 Performance Requirements for Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies
Table 608.1, 608.13.2
1048—05 Performance Requirements for Double-Check Detector Fire Protection
Backflow Prevention Assemblies
Table 608.1, 608.13.7
1052—04 Performance Requirements for Hose Connection Backflow Preventers Table 608.1, 608.13.6
1055—97 Performance Requirements for Chemical-Dispensing Systems 608.13.9
1056—01 Performance Requirements for Spill Resistant Vacuum Breaker Table 608.1, 608.13.8
1060—96 Performance Requirements for Outdoor Enclosures for Backflow Prevention Assemblies 608.14.1
1061—06 Performance Requirements for Removable and Non-Removable Push Fit Fittings Table 605.5, 605.15.3
1062—97 Performance Requirements for Temperature Actuated, Flow Reduction Valves to Individual Fixture Fittings 424.7
1066—97 Performance Requirements for Individual Pressure Balancing In-line Valves for Individual Fixture Fittings 604.11
1069—05 Performance Requirements for Automatic Temperature Control Moving Valves 424.4
1070—04 Performance Requirements for Water-temperature Limiting Devices 408.3, 416.5, 424.5, 607.1
1079—05 Dielectric Pipe Unions 605.24.1, 605.24.3
5013—98 Performance Requirements for Testing Reduced Pressure Principle Backflow Prevention Assembly (RPA) and
Reduced Pressure Fire Protection Principle Backflow Preventers (RFP)
312.10.2
5015—98 Performance Requirements for Testing Double Check Valve Backflow Prevention Assembly (DCVA) 312.10.2
5020—98 Performance Requirements for Testing Pressure Vacuum Breaker Assembly (PVBA) 312.10.2
5047—98 Performance Requirements for Testing Reduced Pressure Detector Fire Protection
Backflow Prevention Assemblies (RPDA)
312.10.2
5048—98 Performance Requirements for Testing Double-Check Valve Detector Assembly (DCDA) 312.10.2
5052—98 Performance Requirements for Testing Hose Connection Backflow Preventers 312.10.2
5056—98 Performance Requirements for Testing Spill-resistant Vacuum Breaker312.10.2

ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
reference
number
Title Referenced
in code
section number
A 53/A53M—06a Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless Table 702.1
A 74—06 Specification for Cast- iron Soil Pipe and Fittings Table 702.1, Table 702.2, Table 702.3,Table 702.4, 708.2, 708.7, Table 1102.4, Table 1102.5, Table 1102.7
A 153/A 153M—09 Specifications for Zinc Coating (Hot Dip) on Iron and Steel Hardware Table 702.4
A 312/A 312M—06 Specification for Seamless and Welded Austenitic Stainless Steel Pipes Table 605.3, Table 605.4, Table 605.5, 605.23.2
A 403/A 403M—11 Specification for Wrought Austenitic Stainless Steel Piping Fittings Table 605.5, Table 605.8
A 518/A 518M—99 (2008) Standard Specification for Corrosion-Resistant High-Silicon Iron Castings Table 702.1
A 778—01 Specification for Welded Unannealed Austenitic Stainless Steel Tubular Products Table 605.3, Table 605.4, Table605.5
A 861—04 (2008) Standard Specification for High-Silicon Iron Pipe and Fittings Table 702.4
A 888—07a Specification for Hubless Cast-iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste, and
Vent Piping Application
Table 702.1, Table 702.2, Table 702.3, Table 702.4, 708.7, Table 1102.4, Table 1102.5, Table 1102.7
B 32—04 Specification for Solder Metal 605.14.3, 605.15.4, 705.9.3, 705.10.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 43—98 (2004) Specification for Seamless Red Brass Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 62—09 Specification for Composition Bronze or Ounce Metal Castings Table 605.5, Table 702.4
B 75—02 Specification for Seamless Copper Tube Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3
B 88—03 Specification for Seamless Copper Water Tube Table 605.3, Table 605.4, Table 702.1, Table 702.2, Table 702.3
B 152/B 152M—06a Specification for Copper Sheet, Strip Plate and Rolled Bar 402.3, 417.5.2.4 425.3.3, 902.2
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and
Copper-alloy Tube
Table 605.3,Table 605.4, Table 702.1, Table 702.2, Table 702.3
B 302—02 Specification for Threadless Copper Pipe, Standard Sizes Table 605.3, Table 605.4, Table 702.1
B 306—02 Specification for Copper Drainage Tube (DWV) Table 702.1, Table 702.2
B 447—07 Specification for Welded Copper Tube Table 605.3, Table 605.4
B 687—99 (2005)e01 Specification for Brass, Copper, and Chromium-plated Pipe Nipples Table 605.8
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of
Copper and Copper Alloy Tube
605.14.3,605.15.4, 705.9.3, 705.10.3
B 828—02 Practice for Making Capillary Joints by Soldering of Copper and
Copper Alloy Tube and Fittings
605.14.3, 605.15.4, 705.9.3, 705.10.3
C 4—04e01 Specification for Clay Drain Tile and Perforated Clay Drain Tile Table 702.3, Table 1102.5
C 14—07 Specification for Non-Reinforced Concrete Sewer, Storm Drain, and Culvert Pipe Table 702.3, Table 1102.4
C 76—07 Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Table 702.3, Table 1102.4
C 400—98 (R2006) Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid Table 1102.4
C 425—04 Specification for Compression Joints for Vitrified Clay Pipe and Fittings Table 702.4, 705.15, 705.19, Table 1102.7
C 443—05a Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets 705.6, 705.19
C 564—04a Specification for Rubber Gaskets for Cast-iron Soil Pipe and Fittings 705.5.2, 705.5.3, 705.19
C 654—03 Standard Specification for Porous Concrete Pipe Table 1102.5
C 700—07 Specification for Vitrified Clay Pipe, Extra Strength,
Standard Strength, and Perforated
Table 702.3, Table 1102.4, Table 1102.5
C 1053—00 (2005) Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and
Vent (DWV) Applications
Table 702.1, Table 702.4
C 1173—06 Specification for Flexible Transition Couplings for
Underground Piping System
705.2.1, 705.6, 705.14.1,705.15, 705.16.2, 705.19
C 1277—06 Specification for Shielded Coupling Joining Hubless Cast-iron Soil Pipe and Fittings 705.5.3
C 1440—03 Specification for Thermoplastic Elastomeric (TPE) Gasket Materials for Drain, Waste, and Vent (DWV),
Sewer, Sanitary and Storm Plumbing Systems
705.19
C 1449/C1449M—05 Standard Specification for Non-Asbestos Fiber-cement Non-Pressure Sewer Pipe Table 702.2, Table 702.3,Table 702.4
C 1450/C1450M—04 (R2010) Standard Specification for Non-asbestos Fiber-cement Storm Drain Pipe Table 1102.4, Table 1102.7
C 1460—04 Specification for Shielded Transition Couplings for Use with Dissimilar DWV Pipe and Fittings Above Ground 705.19
C 1461—06 Specification for Mechanical Couplings Using Thermoplastic Elastomeric (TPE) Gaskets for Joining Drain,
Waste, and Vent (DWV) Sewer, Sanitary and Storm Plumbing Systems for Above and Below Ground Use
705.19
C 1540—04 Specifications for Heavy Duty Shielded Couplings Joining Hubless Cast-iron Soil Pipe andFittings 705.5.3
C 1563—04 Standard Test Method for Gaskets for Use in Connection with Hub and Spigot Cast Iron Soil Pipe and
Fittings for Sanitary Drain, Waste, Vent and Storm Piping Applications
705.5.2
D 1586— 08A Standard Test Method for Standard Penetration Test (SPT) and Split-barrel Sampling of Soils 1114.2.1
D 1587—08 Standard Practice for Thin-walled Tube Sampling of Soils for Geotechnical Purposes 1114.2.
D 1869—95 (2005) Specification for Rubber Rings for Asbestos-cement Pipe 605.24, 705.3, 705.19
D 2235—04 Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and Fittings 705.2.2
D 2464—06 Specification for Threaded Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 1102.7
D 2466—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 Table 1102.7
D 2467—06 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 1102.7
D 2564—04e01 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 705.14.2
D 2657—07 Practice for Heat Fusion-joining of Polyolefin Pipe and Fitting Table 702.1, Table 702.4, 705.16.1
D 2661—06 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain,
Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.4, 705.2.2, 705.7.2
D 2665—07 Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and
Vent Pipe and Fittings
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.7
D 2729—04e01 Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 1102.5
D 2751—05 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings Table 702.4
D 2855—96 (2002) Standard Practice for Making Solvent-cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings 705.14.2
D 2949—01ae01 Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain,
Waste, and Vent Pipe and Fittings
Table 702.1, Table 702.4
D 3034—06 Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings Table 702.3, 702.4, Table 1102.4
D 3212—96a (2003)e01 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals 705.2.1, 705.14.1, 705.16.2
D 3350—02a Specification for High Density Polyethylene Pipe (HPDE) Table 1102.4, Table 1102.7
D 4068—01 Specification for Chlorinated Polyethlene (CPE) Sheeting for Concealed Water-containment Membrane 417.5.2.2
D 4551—96 (2001) Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-containment Membrane 417.5.2.1
F 405—05 Specification for Corrugated Polyethylene (PE) Tubing and Fittings Table 1102.5
F 409—02 Specification for Thermoplastic Accessible and Replaceable Plastic Tube and Tubular Fittings 424.1.2, Table 1102.7
F 437—06 Specification for Threaded Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 1102.4, Table 1102.7
F 438—04 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 40
Table 1102.4, Table 1102.7
F 439—06 Specification for Socket-type Chlorinated Poly (Vinyl Chloride) (CPVC)
Plastic Pipe Fittings, Schedule 80
Table 1102.4, Table 1102.7
F 477—07 Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe 605.24, 705.19
F 628—06e01 Specification for Acrylonitrile-Butadiene-Styrene (ABS)
Schedule 40 Plastic Drain, Waste, and Vent Pipe with a Cellular Core
Table 702.1, Table 702.4, 705.2.2
F 656—02 Specification for Primers for Use in Solvent Cement Joints of
Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings
705.14.2
F 891—04 Specification for Coextruded Poly (Vinyl Chloride)
(PVC) Plastic Pipe with a Cellular Core
Table 702.1, Table 702.2, 702.3, Table 1102.4, Table 1102.5
F 1412—01e01 Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Table 702.1, Table 702.4, 705.17.1
F 1488—03 Specification for Coextruded Composite Pipe Table 702.1, Table 702.2
F 1673—04 Polyvinylidene Fluoride (PVDF) Corrosive Waste Drainage Systems Table 702.1, 702.4, 705.18.1
F 1866—07 Specification for Poly (Vinyl Chloride) (PVC)
Plastic Schedule 40 Drainage and DWV Fabricated Fittings
Table 702.4, Table 1102.7
F 2306/F 2306M—05 12" to 60" Annular Corrugated Profile-wall Polyethylene (PE) Pipe and
Fittings for Gravity Flow Storm Sewer and Subsurface Drainage Applications
Table 1102.7

AWS American Welding Society
550 N.W. Le Jeune Road
Miami, FL 33126
Standard
reference
number
Title Referenced
in code
section number
A5.8—04 Specifications for Filler Metals for Brazing and Braze Welding 605.12.1, 605.14.1,
605.15.1, 705.4.1, 705.9.1, 705.10.1

AWWA American Water Works Association
6666 West Quincy Avenue
Denver, CO 80235
Standard
reference
number
Title Referenced
in code
section number
C104—98 Standard for Cement-mortar Lining for Ductile-Iron Pipe and Fittings for Water 605.5
C110/A21.10—03 Standard for Ductile-iron and Gray-iron Fittings, 3
Inches through 48 Inches, for Water
Table 605.5,Table 702.4, Table 1102.7
C111—00 Standard for Rubber-gasket Joints for Ductile-iron Pressure Pipe and Fittings 605.13
C115/A21.15—99 Standard for Flanged Ductile-iron Pipe with Ductile-iron or Gray-iron Threaded Flanges Table 605.3
C151/A21.51—02 Standard for Ductile-iron Pipe, Centrifugally
Cast for Water
Table 605.3, Table 702.1, Table 702.2, Table 702.3, Table 1102.4
C153—00/A21.53—00 Standard for Ductile-iron Compact Fittings for Water Service Table 605.5
C510—00 Double Check Valve Backflow Prevention Assembly Table 608.1, 608.13.7
C511—00 Reduced-pressure Principle Backflow Prevention Assembly Table 608.1,608.13.2, 608.16.2
C651—99 Disinfecting Water Mains 610.1
C652—02 Disinfection of Water-storage Facilities 610.1

CISPI Cast Iron Soil Pipe Institute
5959 Shallowford Road, Suite 419
Chattanooga, TN 37421
Standard
reference
number
Title Referenced
in code
section number
301—04a Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and
Storm Drain, Waste and Vent Piping Applications
Table 702.1, Table 702.2, Table 702.3, Table 702.4, Table 1102.4, Table 1102.5, Table 1102.7
310—11 Specification for Coupling for Use in Connection with Hubless Cast Iron
Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications
705.5.3

CSA Canadian Standards Association
5060 Spectrum Way
Mississauga, Ontario, Canada L4W 5N6
Standard
reference
number
Title Referenced
in code
section number
B45.1—02 Ceramic Plumbing Fixtures 408.1, 416.1, 418.1, 419.1, 420.1
B45.2—02 Enameled Cast-iron Plumbing Fixtures 407.1, 415.1, 416.1, 418.1
B45.3—02 Porcelain Enameled Steel Plumbing Fixtures 407.1, 416.1, 418.1
B45.4—02 Stainless-Steel Plumbing Fixtures 415.1, 416.1, 418.1, 420.1
B45.5—02 Plastic Plumbing Fixtures 407.1, 416.2, 417.1, 419.1, 420.1, 421.1
B45.9—99 Macerating Systems and Related Components 712.4.1
B64.1.2—01 Vacuum Breakers, Pressure Type (PVB) Table 608.1, 608.13.5
B64.2.1—01 Vacuum Breakers, Hose Connection Type (HCVB) with Manual Draining Feature Table 608.1, 608.13.6
B64.2.1.1—0 Vacuum Breakers, Hose Connection Dual Check Type (HCDVB) Table 608.1, 608.13.6
B64.4.1—01 Backflow Preventers, Reduced Pressure Principle Type for Fire Sprinklers (RPF) Table 608.1, 608.13.2
B64.5—01 Backflow Preventers, Double Check Type (DCVA) Table 608.1, 608.13.7
B64.5.1—01 Backflow Preventers, Double Check Type for Fire Systems (DCVAF) Table 608.1, 608.13.7
B64.6—01 Backflow Preventers, Dual Check Valve Type (DVC) Table 608.1
B64.7—94 Vacuum Breakers, Laboratory Faucet Type (LFVB) Table 608.1, 608.13.6
B64.10/B6410.1—01 Manual for the Selection and Installation of Backflow Prevention Devices/
Manual for the Maintenance and Field Testing of Backflow Prevention Devices
312.10.2
B79—94 (2000) Floor, Area and Shower Drains, and Cleanouts for Residential Construction 412.1
B125—01 Plumbing Fittings 424.1, 424.3, 424.4, 424.6, 425.3.1, 425.4
B125.1—(Rev 1 2005) Plumbing Supply Fittings 424.2, 424.3, 607.4
B125.2—(Rev 1 2005) Plumbing Waste Fittings 424.1.2
B125.3—2005 Plumbing Fittings 416.5, 424.5, Table 608.1
B137.2—02 PVC Injection-Moulded Gasketed Fittings for Pressure Applications Table 1102.7
B137.3—02 Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications 705.14.2
B181.1—02 ABS Drain, Waste, and Vent Pipe and Pipe Fittings Table 702.1, Table 702.4, 705.2.2, 715.2
B181.2—02 PVC Drain, Waste, and Vent Pipe and Pipe Fittings—with
Revisions through December 1993
Table 702.1, Table 702.2, Table 702.3, 705.14.2, 715.2, Table 1102.4
B182.1—02 Plastic Drain and Sewer Pipe and Pipe Fittings 705.14.2
B182.2—02 PVC Sewer Pipe and Fittings (PSM Type) Table 702.3,Table 1102.4, Table 1102.5
B182.6—02 Profile Polyethylene Sewer Pipe and Fittings for Leak-proof Sewer Applications Table 1102.5
B182.8—02 Profile Polyethylene Storm Sewer and Drainage Pipe and Fittings Table 1102.5
CAN/CSA-A257.1M—92 Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
CAN/CSA-A257.2M—92 Reinforced Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings Table 702.3, Table 1102.4
CAN/CSA-A257.3M—92 Joints for Circular Concrete Sewer and Culvert Pipe, Manhole
Sections, and Fittings Using Rubber Gaskets
705.6, 705.19
CAN/CSA-B64.1.1—01 Vacuum Breakers, Atmospheric Type (AVB) 425.2, Table 608.1, 608.13.6, 608.16.4.1
CAN/CSA-B64.2—01 Vacuum Breakers, Hose Connection Type (HCVB) Table 608.1, 608.13.6
CAN/CSA-B64.2.2—01 Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature Table 608.1, 608.13.6
CAN/CSA-B64.3—01 Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP) Table 608.1, 608.13.3, 608.16.2
CAN/CSA-B64.4—01 Backflow Preventers, Reduced Pressure Principle Type (RP) Table 608.1, 608.16.2
CAN/CSA-B181.3—02 Polyolefin Laboratory Drainage Systems Table 702.1, Table 702.4, 705.17.1
CAN/CSA-B182.1—02 Plastic Drain and Sewer Pipe and Pipe Fittings Table 1102.5
CAN/CSA-B182.4—02 Profile PVC Sewer Pipe and Fittings Table 702.3, Table 1102.4, Table 1102.5
CAN/CSA-B602—02 Mechanical Couplings for Drain, Waste, and
Vent Pipe and Sewer Pipe
705.2.1, 705.5.3, 705.6, 705.14.1, 705.15, 705.16.2, 705.19

IAPMO International Association of Plumbing and Mechanical Officials
5001 E. Philadelphia Street
Ontario, CA 91761
Standard
reference
number
Title Referenced
in code
section number
PS48—92 Material Safety Data Verification for Plumbing Products 605.6
PS74—95 Reinforced Water Connectors 605.6
PS117—08 Copper and Copper Allow Tubing System Incorporating Press-type or Nail-type Connections 605.15.3

ICC International Code Council
500 New Jersey Ave. NW
Washington, DC 20001
Standard
reference
number
Title Referenced
in code
section number
ICC-ES PMG LC 1002—10 PMG Listing Criteria for Press-connection Fittings for Potable Water Tube and
Radiant Heating Systems
605.15.3


ISEA International Safety Equipment Association
1901 N. Moore Street, Suite 808
Arlington, VA 22209
Standard
reference
number
Title Referenced
in code
section number
Z358.1—98 Emergency Eyewash and Shower Equipment 411.1

NFPA National Fire Protection Association
Batterymarch Park
Quincy, MA 02169-747
Standard
reference
number
Title Referenced
in code
section number
51—02 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting, and Allied Processes 1203.1
55—10 Standard for the Storage, Use, and Handling of Compressed Gases and
Cryogenic Fluids in Portable, Stationary Containers, Cylinders and Tanks
1203.1
99—05 Standard for Health Care Facilities 1202.1


NSF NSF International
789 Dixboro Road
Ann Arbor, MI 48105
Standard
reference
number
Title Referenced
in code
section number
3—2007 Commercial Warewashing Equipment 409.1
14—2007 Plastic Piping System Components and Related Materials 303.3, 611.3
18—1996 Manual Food and Beverage Dispensing Equipment 426.1
42—2007e Drinking Water Treatment Units—Aesthetic Effects 611.1, 611.3
44—2004 Residential Cation Exchange Water Softeners 611.1, 611.3
53—2007 Drinking Water Treatment Units—Health Effects 611.1, 611.3
58—2006 Reverse Osmosis Drinking Water Treatment Systems 611.2, 611.3
61—2007a Drinking Water System Components—Health Effects 410.1, 424.1, 605.3.1, 605.4, 605.5, 611.3
62—2004 Drinking Water Distillation Systems 611.1
372—2011 Drinking Water System Components — Lead Content 605.2

PDI Plumbing and Drainage Institute
800 Turnpike Street, Suite 300 North
Andover, MA 01845
Standard
reference
number
Title Referenced
in code
section number
G101 (2003) Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data 1003.3.4

WaterSense WaterSense U.S. Environmental Protection Agency Office of Wastewater Management (4204M)
1200 Pennsylvania Avenue, N.W.
Washington, D.C. 20460
Standard
reference
number
Title Referenced
in code
section number
v.1.0—October 1, 2007 High-efficiency Lavatory Faucet Specifications 604.4.1
v.1.0—January 24, 2007 Tank-type High-efficiency Toilet Specification 604.4.1
v.1.0—August 14, 2007 WaterSense Specification for Flushing Urinals 604.4.1
v.1.0—March 4, 2010 WaterSense Specification for Showerheads 604.4.1