This chapter lists the standards that are referenced in this code.
The edition of each standard referenced in this code shall be as indicated by the standard reference number.
The application of the referenced standards and their relationship with the provisions of this code and the rules shall be as set forth in FC102.6.
ANSI
Standard
Reference
Number
Reference
Number
Title
Reserved.
API
American Petroleum Institute
1220 L Street, Northwest
Washington, DC 20005-4070
1220 L Street, Northwest
Washington, DC 20005-4070
Standard
Reference
Number
Reference
Number
Title
Std 650—2007
Std 653—2009
Tank Inspection, Repair, Alteration, and Reconstruction, 4th edition, including Addendum 1 (2010) and Addendum 2 (2012)
RP 1604—1996
Reaffirmed 2010
Reaffirmed 2010
Closure of Underground Petroleum Storage Tanks
Std 2000—2009
Venting Atmosphere and Low Pressure Storage Tanks: Nonrefrigerated and Refrigerated
RP 2028—2002
Reaffirmed 2012
Reaffirmed 2012
Flame Arrestors in Piping Systems
RP 2350—2012
Overfill Protection for Storage Tanks in Petroleum Facilities, 4th edition
ASHRAE
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329Standard
Reference
Number
Reference
Number
Title
15—2013
Safety Standard for Refrigeration Systems
ASME
The American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
Three Park Avenue
New York, NY 10016-5990
Standard
Reference
Number
Reference
Number
Title
A13.1—15
Scheme for the Identification of Piping Systems
B31.1—12
Power Piping
B31.3—12
Process Piping
B31.9—17
Building Services Piping
BPVC—2010
ASME Boiler and Pressure Vessel Code, (Sections I, II, IV, V, VI and VIII), including 2011 addenda
ASTM
ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
Standard
Reference
Number
Reference
Number
Title
D 56—05(2010)
Test Method for Flash Point by Tag Closed Tester
D 86—2012
Test Method for Distillation of Petroleum Products at Atmospheric Pressure
D 92—12b
Test Method for Flash and Fire Points by Cleveland Open Cup
D 93—12
Test Method for Flash Point by Pensky-Martens Closed Cup Tester
D 323—08
Test Method for Vapor Pressure of Petroleum Products (Reid Method)
D 3278—96(2011)
Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus
E 681—09
Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases)
E 1354—13
Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
E 1529—13
Test Method for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies
E 1590—13
Test Method for Fire Testing of Mattresses
F 2200—13
Standard Specification for Automated Vehicular Gate Construction
CA
State of California Department of Consumer Affairs
Bureau of Home Furnishings and Thermal Insulation
3485 Orange Grove Avenue
North Highlands, CA 95660-5595
Bureau of Home Furnishings and Thermal Insulation
3485 Orange Grove Avenue
North Highlands, CA 95660-5595
Standard
Reference
Number
Reference
Number
Title
California Technical
Bulletin 116
Bulletin 116
Requirements, Test Procedure and Apparatus for Testing the Flame Retardance of Upholstered Furniture
California Technical
Bulletin 117—2013
Bulletin 117—2013
Requirements, Test Procedure and Apparatus for Testing the Smolder Resistance of Materials Used in Upholstered Furniture
California Technical
Bulletin 129—1992
Bulletin 129—1992
Flammability Test Procedure for Mattresses for Use in Public Buildings
CGA
Standard
Reference
Number
Reference
Number
Title
C-7—(2011)
Guide to the Preparation of Precautionary Labeling and Marking of Compressed Gas Containers
G-8.1—(2007)
Nitrous Oxide Systems at Consumer Sites
G-13—(2006)
Storage and Handling of Silane and Silane Mixtures
P-1—(2008)
Safe Handling of Compressed Gases in Containers
S-1.1—(2011)
Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases
S-1.2—(2005)
Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases
S-1.3—(2008)
Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases
V-1—(2005)
Standard for Gas Cylinder Valve Outlet and Inlet Connections
CGR
Coast Guard Regulations
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
Reference
Number
Reference
Number
Title
Reserved.
CPSC
Standard
Reference
Number
Reference
Number
Title
16 CFR Section 1500.41
Method for Testing Primary Irritant Substances
16 CFR Section 1500.42
Test for Eye Irritants
16 CFR Section 1500.44
Method for Testing Extremely Flammable and Flammable Solids
DOC
Standard
Reference
Number
Reference
Number
Title
16 CFR Part 1632
Standard for the Flammability of Mattress and Mattress Pads (FF 4—72, Amended)
DOJ
U.S. Department of Justice
Bureau of Alcohol, Tobacco, Firearms and Explosives
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Bureau of Alcohol, Tobacco, Firearms and Explosives
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
Reference
Number
Reference
Number
Title
27 CFR Part 555
Commerce in Explosives
DOL
U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
c/o Superintendent of Documents
U.S. Government Printing Office
Washington, DC 20402-9325
Standard
Reference
Number
Reference
Number
Title
29 CFR Section 1910.1000
Air Contaminants
29 CFR Section 1910.1200
Hazard Communication
U.S. Department of Transportation
Office of Hazardous Material Standards
400 7th Street, Southwest
Washington, DC 20590
Office of Hazardous Material Standards
400 7th Street, Southwest
Washington, DC 20590
Standard
Reference
Number
Reference
Number
Title
49 CFR Parts (100-180)
Hazardous Materials Regulations
49 CFR Parts 190-199
Pipeline Safety
49 CFR Parts 350-399
Federal Motor Carrier Safety Regulations
EN
European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Central Secretariat
Rue de Stassart 36
B-10 50 Brussels
Standard
Reference
Number
Reference
Number
Title
European Standard
EN 1081: 1998
EN 1081: 1998
Resilient Floor Coverings—Determination of the Electrical Resistance
EPA
Environmental Protection Agency
Ariel Rios Building
1200 Pennsylvania Avenue, NW
Washington, DC 20460
Ariel Rios Building
1200 Pennsylvania Avenue, NW
Washington, DC 20460
Standard
Reference
Number
Reference
Number
Title
40 CFR Part 112
Oil Pollution Prevention
40 CFR Part 280
FM
Factory Mutual Global Research
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston, RI 02919
Standards Laboratories Department
1301 Atwood Avenue, P.O. Box 7500
Johnston, RI 02919
Standard
Reference
Number
Reference
Number
Title
ANSI/FM 4996—13
Approval Standard for Classification of Pallets and Other Material Handling Products as Equivalent to Wood Pallets
IIAR
International Institute of Ammonia Refrigeration
1001 N. Fairfax Street, Suite 503
Alexandria, VA 22314
1001 N. Fairfax Street, Suite 503
Alexandria, VA 22314
Standard
Reference
Number
Reference
Number
Title
IIAR-2—2014
Equipment, Design and Installation of Closed-Circuit Ammonia Refrigerating Systems
IIAR-6—2019
Inspection, Testing, and Maintenance of Safe Closed-Circuit Ammonia Refrigeration Systems
IIAR-7—2019
Developing Operating Procedures for Closed-Circuit Ammonia Mechanical Refrigerating Systems
IIAR-8—2020
Decommissioning of Closed-Circuit Ammonia Refrigeration Systems
IIAR-9—2020
IKECA
International Kitchen Exhaust Cleaning Association
100 North 20th Street, Suite 400
Philadelphia, PA 19103
100 North 20th Street, Suite 400
Philadelphia, PA 19103
Standard
Reference
Number
Reference
Number
Title
C10—2011
ANSI/IKECA
ANSI/IKECA
Standard for Cleaning of Commercial Kitchen Exhaust Systems
ISO
International Organization for Standardization (ISO)
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case postale 56
CH-1211 Geneva 20, Switzerland
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case postale 56
CH-1211 Geneva 20, Switzerland
Standard
Reference
Number
Reference
Number
Title
ISO 8115—86
Cotton Bales—Dimensions and Density
NEMA
National Electrical Manufacturer's Association
1300 N. 17th Street
Suite 1847
Rosslyn, VA 22209
1300 N. 17th Street
Suite 1847
Rosslyn, VA 22209
Standard
Reference
Number
Reference
Number
Title
250—2003
Enclosures for Electrical Equipment (1,000 Volt Maximum)
NFPA
Standard
Reference
Number
Reference
Number
Title
2—16
Hydrogen Technologies Code
10—13
Portable Fire Extinguishers
11—10
Low-, Medium- and High-Expansion Foam
12—11
Carbon Dioxide Extinguishing Systems
12A—09
Halon 1301 Fire Extinguishing Systems
13—16
Installation of Sprinkler Systems
13R—16
Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies
16—15
Installation of Foam-Water Sprinkler and Foam-Water Spray Systems
20—16
Installation of Stationary Pumps for Fire Protection
24—13
Installation of Private Fire Service Mains and their Appurtenances
25—14
Inspection, Testing and Maintenance of Water-Based Fire Protection Systems
30—12
Flammable and Combustible Liquids Code
30A—15
30B—15
Manufacture and Storage of Aerosol Products
32—16
Standard for Drycleaning Facilities
33—16
Spray Application Using Flammable or Combustible Materials
34—15
Dipping, Coating, and Printing Processes Using Flammable or Combustible Liquids
35—11
Manufacture of Organic Coatings
40—11
Storage and Handling of Cellulose Nitrate Film
51—13
Design and Installation of Oxygen-Fuel Gas Systems for Welding, Cutting, and Allied Processes
52—13
Vehicular Natural Gas Fuel Systems Code
55—13
Compressed Gases and Cryogenic Fluids Code
56—12
Standard for Fire and Explosion Prevention During Cleaning and Purging of Flammable Gas Piping Systems
58—14
61—13
68—2018
Standard on Explosion Protection by Deflagration Venting
72—16
National Fire Alarm and Signaling Code
76—16
Standard for the Fire Protection of Telecommunications Facilities
77—07
Recommended Practice on Static Electricity
80—13
Fire Doors and Other Opening Protectives
85—15
Boiler and Combustion System Hazards Code
86—15
Ovens and Furnaces
88A—19
Standard for Parking Structures
96—17
Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations
99—15
Health Care Facilities Code
105—13
Standard for Smoke Door Assemblies and Other Opening Protectives
110—13
Emergency and Standby Power Systems
111—13
Stored Electrical Energy Emergency and Standby Power Systems
120—15
Fire Prevention and Control in Coal Mines
130—20
Fixed Guideway Transit and Passenger Rail Systems
140—18
Standard on Motion Picture and Television Production Studio Soundstages, Approved Production Facilities, and Production Locations
160—11
Use of Flame Effects Before an Audience
241—13
Safeguarding Construction, Alteration, and Demolition Operations
260—13
Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture
261—13
Method of Test for Determining Resistance of Mock-Up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes
289—13
Method of Fire Test for Individual Fuel Packages
318—15
Standard for the Protection of Semiconductor Fabrication Facilities
326—10
Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning or Repair
385—12
Standard for Tank Vehicles for Flammable and Combustible Liquids
400—13
Hazardous Materials Code
407—12
Aircraft Fuel Servicing
484—15
Combustible Metals
495—13
Explosive Materials Code
498—13
Safe Havens and Interchange Lots for Vehicles Transporting Explosives
502—20
Road Tunnels, Bridges and Other Limited Access Highways
505—13
Fire Safety Standard for Powered Industrial Trucks Including Type Designations, Areas of Use, Conversions, Maintenance, and Operations
652—16
Standard on the Fundamentals of Combustible Dust
654—13
Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids
655—12
Prevention of Sulfur Fires and Explosions
664—12
701—10
Standard Methods of Fire Tests for Flame-Propagation of Textiles and Films
704—12
Identification of the Hazards of Materials for Emergency Response
720—15
Installation of Carbon Monoxide (CO) Detection and Warning Equipment
750—15
Standard on Water Mist Fire Protection Systems
780—08
Standard for the Installation of Lightning Protection Systems
820—08
Fire Protection in Wastewater Treatment and Collection Facilities
850—10
Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations
855—20
Standard for the Installation of Stationary Energy Storage Systems
1122—13
Model Rocketry
1123—14
1124—17
Code for the Manufacture, Transportation, Storage, and Retail Sales of Fireworks and Pyrotechnic Articles
1125—12
Manufacture of Model Rocket and High Power Rocket Motors
1126—11
Use of Pyrotechnics Before a Proximate Audience
1127—13
High Power Rocketry
2010—15
UL
Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062
333 Pfingsten Road
Northbrook, IL 60062
Standard
Reference
Number
Reference
Number
Title
30—95
Metal Safety Cans—with Revisions through July 2009
80—07
Standard for Steel Tanks for Oil-Burner Fuels and Other Combustible Liquids—with revisions through August 2009
142—06
Standard for Steel Aboveground Tanks for Flammable and Combustible Liquids—with revisions through February 12, 2010
268—09
Standard for Smoke Detectors for Fire Alarm Systems
300—05
Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with revisions through July 2010
300A—06
Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces
325—02
Door, Drapery, Gate, Louver, and Window Operators and Systems—with Revisions through February 2006
499—05
Standard for Electric Heating Appliances—with revisions through February 2013
864—03
Standard for Control Units and Accessories for Fire Alarm Systems—with revisions through December 2014
900—04
Air Filter Units—with revisions through February 2012
1275—05
Flammable Liquid Storage Cabinets—with Revisions through February 2010
1313—93
Standard for Nonmetallic Safety Cans for Petroleum Products—with Revisions through November 2012
1315—95
Standard for Safety for Metal Waste Paper Containers—with Revisions through September 2012
1564—15
Standard for Industrial Battery Chargers
1741—10
Standard for Inverters, Converters, Controllers and Interconnection System Equipment for Use With Distributed Energy Resources
1973—18
Standard for Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications
1975—06
Fire Tests for Foamed Plastics Used for Decorative Purpose
2017—08
Standard for General-Purpose Signaling Devices and Systems—with revisions through May 2011
2075—13
Standard for Gas and Vapor Detectors and Sensors
2085—97
Protected Aboveground Tanks for Flammable and Combustible Liquids—with Revisions through September 2010
2200—12
Standard for Stationary Engine Generator Assemblies—with revisions through June 2013
2208—10
Solvent Distillation Units—with revisions through March 2011
2272—16
Standard for Electrical Systems for Personal E-Mobility Devices
2335—10
Fire Tests of Storage Pallets—with Revisions through September 2012
2360—00
Standard for Test Methods for Determining the combustibility characteristics of Plastics Used in Semi-Conductor Tool Construction—with revisions through May 2013
2849—20
Standard for Electrical Systems for eBikes
9540—20
Standard for Energy Storage Systems and Equipment