This chapter lists the standards that are referenced in various sections of the commercial provisions of this code. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section ECC 105. Refer to the rules of the department for any subsequent additions, modifications or deletions that may have been made to the referenced standards set forth herein in accordance with Section 28-103.19 of the Administrative Code.

AAMA

American Architectural Manufacturers Association
1827 Walden Office Square
Suite 550
Schaumburg IL 60173-4268

AAMA/WDMA/CSA 101/I.S.2/A C440—17:

North American Fenestration Standard/Specifications for Windows, Doors and Unit Skylights

R402.4.3

ACCA

Air Conditioning Contractors of America
2800 Shirlington Road, Suite 300
Arlington VA 22206

ANSI/ACCA 9QIvp—2016:

HVAC Quality Installation Verification Protocols

R403.6.3

Manual J—11:

Residential Load Calculation Eighth Edition

R403.7

Manual S—14:

Residential Equipment Selection

R403.7

ANSI

American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY 10036

ANSI/ACCA 9QIvp—2016:

HVAC Quality Installation Verification Protocols

R403.6.3

ANSI/ASHRAE/IESNA 90.1—2016:

Energy Standard for Buildings Except Low-rise Residential Buildings

CH 1 (Intro Statement), 101.1.1, R202

ANSI/ASHRAE/IES 90.1—2016

(AS AMENDED) with revisions as set forth in Appendix CA of this code

101.1.1, 101.5.1.1, 105.1, R202, R402.6.1

ANSI/APSP/ICC 14—2014:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency-includes Addenda A Approved January 9, 2013

R403.12

ANSI/DASMA 105—2016:

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

ANSI Z 65—1996:

Method for Measuring Floor Area in Office Buildings

R402.4.1.2, R402.4.1.3

APSP

The Association of Pool & Spa Professionals
2111 Eisenhower Avenue, Suite 500
Alexandria VA 22314

ANSI/APSP/ICC 14—2014:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

ANSI/ASHRAE/IESNA 90.1—2016:

Energy Standard for Buildings Except Low-rise Residential Buildings

CH 1 (Intro Statement), 101.1.1, R202

ANSI/ASHRAE/IES 90.1—2016

(AS AMENDED) with revisions as set forth in Appendix CA of this code

101.1.1, 101.5.1.1, 105.1, R202, R402.6.1

ASHRAE—2017:

ASHRAE Handbook of Fundamentals

R402.1.5

ASHRAE—2001:

2001 ASHRAE Handbook of Fundamentals

Table R405.5.2(1)

ASHRAE 193—2010(RA 2014):

Method of Test for Determining the Airtightness of HVAC Equipment

R403.3.2.1

ASHRAE Research Project 1365—2011:

Thermal Performance of Building Envelope Details for Mid-and High-Rise Buildings

Table R402.6

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

C1363—11:

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus

R303.1.4.1

E283—04(2012):

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen

R202, R402.4.5

E779—10:

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization

R402.4.1.2, R402.4.1.3

E1827—11:

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door

R402.4.1.2

E2178—13:

Standard Test Method for Air Permeance of Building Method

R202

BC HYDRO

BC Hydro Power Smart
333 Dunsmuir Street
Vancouver BC V6B 5R3

Building Envelope Thermal Bridging Guide Version 1.2—18


Table R402.6

BOMA

Building Owners and Managers Association (BOMA) International
1101 15th Street. NW Suite 800
Washington DC 20005

ANSI/BOMA Z65.1—1996:

Standard Method for Measuring Floor Area in Office Buildings

R402.4.1.2, R402.4.1.3

CSA

CSA Group
8501 East Pleasant Valley Road
Cleveland OH 44131-5516

AAMA/WDMA/CSA 101/I.S.2/A440—17:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3

CSA B55.1—2015:

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Units

R403.5.4

CSA B55.2—2015:

Drain Water Heat Recovery Units

R403.5.4

DASMA

1300 Sumner Avenue
Cleveland OH 44115-2851

105—2016:

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors

R303.1.3

DOE

U.S. Department of Energy
c/o Superintendent of DocumentsU.S. Government Printing OfficeWashington DC 20402-9325

(Current Edition):

State Energy Price and Expenditure Report

R405.3

HVI

Home Ventilating Institute
1000 North Rand Road, Suite 214
Wauconda IL 60084

916—09:

Airflow Test Procedure

Table R403.6.1

ICC

International Code Council, Inc.
500 New Jersey Avenue NW
6th Floor
Washington DC 20001

ANSI/APSP/ICC 14—2014:

American National Standard for Portable Electric Spa Energy Efficiency

R403.11

ANSI/APSP/ICC 15a—2011:

American National Standard for Residential Swimming Pool and Spa Energy Efficiency—includes Addenda A Approved January 9, 2013

R403.12


ICC 400—17:

Standard on the Design and Construction of Log Structures

R402.1, Table R402.4.1.1


IECC—18:

International Energy Conservation Code®

CH 1 (Intro Statement), 101.1.1


IECC—06:

2006 International Energy Conservation Code®

R202


ANSI/RESNET/ICC 301—2014:

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016, including Addenda D, E, G and K

R406.3, R406.6.1, R406.6.5

ANSI/RESNET/ICC 380—2016:

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems and Airflow of Mechanical Ventilation Systems—Republished January 2016, including Addendum A

R402.4.1.2

IEEE

Institute of Electrical and Electronic Engineers, Inc.
3 Park Avenue, 17th Floor
New York NY 10016-5997

515.1—2012:

IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications

R403.5.1.2

IES

Illuminating Engineering Society
120 Wall Street, 17th Floor
New York NY 10005-4001

ANSI/ASHRAE/IESNA 90.1—2016:

Energy Standard for Buildings Except Low-rise Residential Buildings

CH 1 (Intro Statement), 101.1.1, R202

ANSI/ASHRAE/IES 90.1—2016

(AS AMENDED) with revisions as set forth in Appendix CA of this code

101.1.1, 101.5.1.1, 105.1, R202, R402.6.1


NFRC

National Fenestration Rating Council, Inc.
6305 Ivy Lane, Suite 140
Greenbelt MD 20770

100—2017:

Procedure for Determining Fenestration Products U-factors

R303.1.3

200—2017:

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence

R303.1.3

400—2017:

Procedure for Determining Fenestration Product Air Leakage

R402.4.3

NYC

New York City Department of Buildings
280 Broadway
New York NY 10007

NYCCC—14:

New York City Construction Codes

101.2.1, 102.1, 103.1, 104.2.3, R201.3, R201.4, R402.4.2, R501.4

NYCECC—16:

New York City Energy Conservation Code

Table R406.4

NYCECC—11:

New York City Energy Conservation Code

R406.2

NYS

New York Department of State
One Commerce Plaza, 99 Washington Ave
Albany NY 12231-000

BCNYS—20:

Building Code of New York State

R202

ECCCNYS—20:

Energy Conservation Construction Code of New York State

CH1 (Intro Statement), 101.1.1, 101.2.3, 101.3

RESNET

P.O. Box 4561
Oceanside CA 92052-4561

ANSI/RESNET/ICC 301—2014:

Standard for the Calculation and Labeling of the Energy Performance of Low-rise Residential Buildings using an Energy Rating Index First Published March 7, 2014—Republished January 2016, including Addenda D, E, G and K

R406.3, R406.6.1, R406.6.5

ANSI/RESNET/ICC 380—2016:

Standard for Testing Airtightness for Building Enclosures, Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems—Republished January 2016, including Addendum A

R402.4.1.2

UL

UL LLC
333 Pfingsten Road
Northbrook IL 60062

127—11:

Standard for Factory Built Fireplaces—with Revisions through May 2015

R402.4.2

515—11:

Electrical Resistance Heat Tracing for Commercial and Industrial Applications Including Revisions through July 2015

R403.5.1.2

US-FTC

United States-Federal Trade Commission
600 Pennsylvania Avenue NW
Washington DC 20580

CFR Title 16 (2015):

R-value Rule

R303.1.4

WDMA

Window and Door Manufacturers Association
2025 M Street NW, Suite 800
Washington DC 20036-3309

AAMA/WDMA/CSA 101/I.S.2/A440—17:

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights

R402.4.3