This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Chapter 1.

* Denotes standards that are incorporated by reference into 19 NYCRR Part 1223.

Margin markings have not been made in this chapter. The date of the reference standards denotes the new standards from 2007.

 

ACCA Air Conditioning Contractors of America
1712 New Hampshire Ave, NW
Washington, DC 20009
  
Standard
reference
number
Title Referenced
in code
section number
* Manual D—95 Residential Duct Systems 603.2
ANSI

American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036


 
Standard
reference
number
Title Referenced
in code
section number
* Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners 919.1
Z21.50—03 Vented Gas Fireplaces—with Addendum Z21.50a—2003 (ANSI Z21.50/CSA 2.22) 901.6
Z21.60—03 Decorative Gas Appliances for Installation in Solid-fuel Burning
    Fireplaces—with Addendum Z21.60a—2003 (ANSI Z21.60/CSA 2.26)
901.6
ARI

Air-Conditioning and Refrigeration Institute
Suite 425
4301 North Fairfax Drive
Arlington, VA 22203
 
Standard
reference
number
Title Referenced
in code
section number
700—99 Purity Specifications for Fluorocarbon and Other Refrigerants 1102.2.2.3
ASHRAE

American Society of Heating, Refrigerating
and Air-Conditioning Engineers, Inc.
1791 Tullie Circle, NE
Atlanta, GA 30329-2305
 
Standard
reference
number
Title Referenced
in code
section number
* ASHRAE—2005 ASHRAE Handbook of Fundamentals—2005 312.1, 603.2
* 15—2001 Safety Standard for Refrigeration Systems 1101.6, 1105.8, 1108.1
* 34—2004 Designation and Safety Classification of Refrigerants 202, 1102.2.1, 1103.1
* ASHRAE—2004 HVAC Systems and Equipment Handbook—2004 312.1
ASME

American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title Referenced
in code
section number
B1.20.1—1983 (R2001) Pipe Threads, General Purpose (Inch) 1203.3.5, 1303.3.3
B16.3—1998 Malleable Iron Threaded Fittings, Classes 150 & 300 Table 1202.5
B16.5—1996 Pipe Flanges and Flanged Fittings NPS 1/2 through NPS 24—With B16.5a—1998 Addenda Table 1202.5
B16.9—2003 Factory Made Wrought Steel Buttwelding Fittings Table 1202.5
B16.11—2001 Forged Fittings, Socket-welding and Threaded Table 1202.5
B16.15—1985 (R1994) Cast Bronze Threaded Fittings Table 1202.5
B16.18—2001 Cast Copper Alloy Solder Joint Pressure Fittings 513.13.1, Table 1202.5
B16.22—2001 Wrought Copper and Copper Alloy Solder Joint Pressure
    Fittings—with B16.22a—1998 Addenda
513.13.1, Table 1202.5
B16.23—2002 Cast Copper Alloy Solder Joint Drainage Fittings DWV Table 1202.5
B16.24—2001 Cast Copper Alloy Pipe Flanges and Flanged Fittings: Class 150, 300, 400, 600, 900, 1500
    and 2500
Table 1202.5
B16.26—1988 Cast Copper Alloy Fittings for Flared Copper Tubes Table 1202.5
B16.28—1994 Wrought Steel Buttwelding Short Radius Elbows and Returns Table 1202.5
B16.29—2001 Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings—DWV Table 1202.5
BPVC—2004 Boiler & Pressure Vessel Code (Sections I, II, IV, V & VI) 1004.1, 1011.1
CSD-1—2002 Controls and Safety Devices for Automatically Fired Boilers 1004.1
ASSE

American Society of Sanitary Engineering
28901 Clemens Road, Suite A
Westlake, OH 44145
 
Standard
reference
number
Title Referenced
in code
section number
1017—99 Performance Requirements for Temperature Actuated Mixing Values for Hot Water
    Distribution Systems
1002.2.2
ASTM

ASTM International
100 Barr Harbor Drive
West Conshohocken , PA 19428
 
Standard
reference
number
Title Referenced
in code
section number
A 53/A 53M—02 Specification for Pipe, Steel, Black and Hot-dipped, Zinc-coated Welded and Seamless Table 1202.4,
Table 1302.3
A 106—04 Specification for Seamless Carbon Steel Pipe for High-temperature Service Table 1202.4, Table 1302.3
A 126—04 Specification for Gray Iron Castings for Valves, Flanges and Pipe Fittings Table 1202.5
A 254—97 (2002) Specification for Copper Brazed Steel Tubing. Table 1202.4, Table 1302.3
A 420/A 420M—04 Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for
    Low-temperature Service
Table 1202.5
A 539—99 Specification for Electric-resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines Table 1302.3
B 32—03 Specification for Solder Metal 1203.3.3
B 42—02e01 Specification for Seamless Copper Pipe, Standard Sizes 513.13.1, 1107.4.2, Table 1202.4, Table 1302.3
B 43—04 Specification for Seamless Red Brass Pipe, Standard Sizes 513.13.1, 1107.4.2, Table 1202.4, Table 1302.3
B 68—02 Specification for Seamless Copper Tube, Bright Annealed 513.13.1
B 75—02 Specification for Seamless Copper Tube Table 1202.4, Table 1302.3
B 88—03 Specification for Seamless Copper Water Tube 513.13.1, 1107.4.3, Table 1202.4, Table 1302.3
B 135—02 Specification for Seamless Brass Tube Table 1202.4, Table 1302.3
B 251—02e01 Specification for General Requirements for Wrought Seamless Copper and
    Copper-alloy Tube
513.13.1, 1107.4.3, Table 1202.4
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration
    Field Service
513.13.1, 1107.4.3, Table 1302.3
B 302—02 Specification for Threadless Copper Pipe, Standard Sizes Table 1202.4, Table 1302.3
B 813—00e01 Specification for Liquid and Paste Fluxes for Soldering of Copper and Copper Alloy Tube 1203.3.3
C 315—02 Specification for Clay Flue Linings 801.16.1, Table 803.10.4
C 411—97 Test Method for Hot-surface Performance of High-temperature Thermal Insulation 604.3
  ASTM—continued  
D 56—02a Test Method for Flash Point by Tag Closed Tester 202
D 93—02a Test Method for Flash Point of Pensky-Martens Closed Cup Tester 202
D 1527—99e01 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe, Schedules 40 and 80 Table 1202.4
D 1693—01 Test Method for Environmental Stress-cracking of Ethylene Plastics Table 1202.4
D 1785—04 Specification for Poly (Vinyl Chloride)(PVC) Plastic Pipe, Schedules 40, 80 and 120 Table 1202.4
D 2235—01 Specifications for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe
    and Fittings
1203.3.4
D 2241—04a Specification for Poly (Vinyl Chloride) (PVC) Pressure-rated Pipe (SDR-Series) Table 1202.4
D 2282—99e01 Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe (SDR-PR) Table 1202.4
D 2412—02 Test Method for Determination of External Loading Characteristics of Plastic Pipe
    by Parallel-plate Loading
603.8.3
D 2447—03 Specification for Polyethylene (PE) Plastic Pipe, Schedules 40 and 80, Based on Outside
   Diameter
Table 1202.4
D 2466—02 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2467—04 Specification for Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 Table 1202.5
D 2468—96a Specification for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe Fittings, Schedule 40 Table 1202.5
D 2513—04a Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings Table 1202.4, 1203.15.3
D 2564—02 Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Piping Systems 1203.3.4
D 2683—98 Specification for Socket-type Polyethylene Fittings for Outside Diameter-controlled
   Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.1
D 2837—04 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials Table 1202.4
D 2846/D 2846M—99 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold
   Water Distribution Systems
Table 1202.4, 1203.3.4
D 2996—01 Specification for Filament-wound Fiberglass (Glass Fiber Reinforced Thermosetting
   Resin) Pipe
Table 1302.3
D 3035—03a Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Controlled Outside
   Diameter
Table 1202.4
D 3278—96e1 Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus 202
D 3350—02a Specification for Polyethylene Plastics Pipe and Fittings Materials Table 1202.4
E 84—05 Test Method for Surface Burning Characteristics of Building Materials 202, 510.8, 602.2.1, 602.2.1.5,
604.3, 1204.1
E 119—08a Test Method for Fire Tests of Building Construction
   and Materials
302.2.2.1, 302.2.3.1.1, 607.5.2, 607.5.5, 607.6.1, 607.6.2.1
E 136—99e01 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C 202
E 814—02 Test Method for Fire Tests of Through-penetration Fire Stops 202, 302.2.2.1.2, 302.2.3.1.1.2, 506.3.10
E 1509—04 Specification for Room Heaters, Pellet Fuel-burning Type 904.1
E 2231—02 Standard Practice For Specimen Preparation and Mounting of Pipe and Duct
   Insulation Materials to Assess Surface Burning Characteristics
604.3, 1204.1
E 2336—04 Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems 506.3.10
F 402—05 Standard Practice for Safe Handling of Solvent Cements, Primers and Cleaners Used
   for Joining Thermoplastic Pipe and Fitting
801.20
F 438—04 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings,
   Schedule 40
Table 1202.5
F 439—02e01 Specification for Socket Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe
   Fittings, Schedule 80
Table 1202.5
F 441/F 441M—02 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 Table 1202.4
F 442/F 442M—99 Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR-PR) Table 1202.4
F 493—04 Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic
   Pipe and Fittings
1203.3.4
F 876—04 Specification for Crosslinked Polyethylene (PEX) Tubing Table 1202.4
F 877—02e01 Specification for Crosslinked Polyethylene (PEX) Plastic Hot and Cold Water
   Distribution Systems
Table 1202.4, Table 1202.5
F 1055—98e01 Specification for Electrofusion Type Polyethylene Fittings for Outside Diameter
   Controlled Polyethylene Pipe and Tubing
Table 1202.4, 1203.15.2
F 1281—03 Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene
   (PEX-AL-PEX) Pressure Pipe
Table 1202.4
F 1476—95a Specification for Performance of Gasketed Mechanical Couplings for Use in Piping Applications 1203.3.7
F 1974—04 Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene
   and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene
   Composite Pressure Pipe
Table 1202.5
AWS

American Welding Society
550 N.W. LeJeune Road
P.O. Box 351040
Miami, FL 33135
 
Standard
reference
number
Title Referenced
in code
section number
A5.8—04 Specifications for Filler Metals for Brazing and Braze Welding 1203.3.1, 1303.3.1
CSA

Canadian Standards Association
178 Rexdale Blvd.
Rexdale (Toronto), Ontario, Canada M9W 1R3


 
Standard
reference
number
Title Referenced
in code
section number
B137.10M—02 Cross-linked Polyethylene/Aluminum/Cross-linked Polyethylene Composite Pressure Pipe
   Systems
Table 1202.4
CSA America FC1—03 Stationary Fuel Cell Power Systems 924.1
DOL

Department of Labor
Occupational Safety and Health Administration
c/o Superintendent of Documents
US Government Printing Office
Washington, DC 20402-9325
 
Standard
reference
number
Title Referenced
in code
section number
* 29 CFR Part 1910.1000 (1974) Air Contaminants 502.6, 502.19
 
* Note: CFR Standards are available from the Supt. of Documents, U.S. Government Printing Office, Washington, DC 20402-9325.
ICC

International Code Council
500 New Jersey Avenue, NW, 6th Floor
Washingon, D.C. 20001
 
Standard
reference
number
Title Referenced
in code
section number
BCNYS—10 Building Code of New York State 103.4, 201.3, 202, 301.12, 301.13, 301.14, 301.15, 302.2.2.3, 302.2.3, 302.2.3.1.3, 302.2.3.2, 302.2.3.3, 304.7, 304.10, 306.5.1, 308.8, 308.10, 401.5, 406.1, 502.10, 502.10.1, 504.2, 506.3.3, 506.3.10, 506.3.12.2, 506.4.1, 509.1, 510.6, 510.6.2, 510.6.3, 510.7, 511.1.5, 513.1, 513.2, 513.3, 513.4.3, 513.5, 513.5.2, 513.5.2.1, 513.6.2, 513.10.5, 513.12, 513.12.2, 601.3, 602.2.1.5.1, 602.2.1.5.2, 602.3, 603.1, 603.10, 603.17.2, 607.1.1, 607.3.2.1, 607.5.1, 607.5.2, 607.5.3, 607.5.4, 607.5.4.1, 607.5.5, 607.6, 607.6.1, 607.6.2, 607.6.2.1, 607.6.3, 701.4.1, 701.4.2, 801.3, 801.16.1, 801.18.4, 901.6, 902.1, 908.3, 908.4, 910.3, 925.1, 926.1, 1004.6, 1105.1, 1206.4, 1402.4, 1402.4.1
  Chapter 27 Electrical Provisions 104.2, 301.7, 306.3.1, 306.4.1, 306.5.2, 511.1.1, 513.11, 513.12.1, 602.2.1.1, 1106.3, 1106.4
EBCNYS—10 Existing Building Code of New York State. 101.2, 102.7
ECCCNYS—10 Energy Conservation Code of New York State 202, 301.2, 303.3, 312.1, 514.1, 604.1, 1204.1, 1204.2
FCNYS—10 Fire Code of New York State 102.7, 103.4,201.3, 202, 310.1, 311.1, 502.4, 502.5, 502.7.2, 502.8.1, 502.9.5, 502.9.5.2, 502.9.5.3, 502.9.8.2, 502.9.8.3, 502.9.8.5, 502.9.8.6, 502.10, 502.10.3, 502.16.2, 509.1, 510.2.1, 510.2.2, 510.4, 511.1.1, 513.12.3, 513.15, 513.16, 513.17, 513.18, 513.19, 606.2.1, 908.7, 926.1, 1101.9, 1105.3, 1105.9, 1106.5, 1106.6, 1301.1, 1301.2, 1301.5
FGCNYS—10 Fuel Gas Code of New York State 101.2, 201.3, 301.3, 701.1, 801.1, 901.1, 906.1, 926.1, 1101.5
  ICC—continued  
PCNYS—10 Plumbing Code of New York State 201.3, 301.8, 512.2, 908.5, 1002.1, 1002.2, 1002.3, 1005.2, 1006.6, 1008.2, 1009.3, 1101.4, 1201.1, 1206.2, 1206.3, 1206.4, 1401.2
PMCNYS—10 Property Maintenance Code of New York State 102.7
RCNYS—10 Residential Code of New York State 101.2, 901.6
IIAR

International Institute of Ammonia Refrigeration
1001 North Fairfax St.
Suite 503
Alexandria, VA 22314
 
Standard
reference
number
Title Referenced
in code
section number
* 2—08 Equipment, Design, and Installation of Ammonia Mechanical Refrigerating Systems 1101.6
MSSVFI

Manufacturers Standardization Society of the Valve & Fittings Industry, Inc.
127 Park Street, N.E.
Vienna, VA 22180
 
Standard
reference
number
Title Referenced
in code
section number
SP—69—02 Pipe Hangers and Supports-Selection and Application 305.4
NAIMA

North American Insulation Manufacturers Association
Suite 310
44 Canal Center Plaza
Alexandria, VA 22314
 
Standard
reference
number
Title Referenced
in code
section number
AH116—02 Fibrous Glass Duct Construction Standards 603.5, 603.9
NFPA

National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
 
Standard
reference
number
Title Referenced
in code
section number
*30A—08 Code for Motor Fuel-dispensing Facilities and Repair Garages 304.5
* 31—06 Installation of Oil-burning Equipment 801.2.1, 801.18.1, 801.18.2, 920.2, 922.1, 1308.1
* 37—02 Installation and Use of Stationary Combustion Engines and Gas Turbines 915.1, 915.2
* 58—08 Liquefied Petroleum Gas Code 502.9.10
69—08 Explosion Prevention Systems 510.8.3
*70—08 National Electrical Code 1104.2.2
* 72—07 National Fire Alarm Code 513.12, 606.3
82—04 Incinerators and Waste and Linen Handling Systems and Equipment 601.1
85—07 Boiler and Construction Systems Hazards Code 1004.1
91—99 Exhaust Systems for Air Conveying of Vapors, Gases, Mists and Noncombustible
   Particulate Solids
502.9.5.1, 502.17
* 92B—05 Smoke Management Systems in Malls, Atria and Large Spaces 513.8
211—06 Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances 806.1
262—02 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in
   Air-handling Spaces
602.2.1.1
*288—07 Standard Methods of Fire Tests of Floor Fire Door Assemblies Installed
   Horizontally in Fire Resistance-Rated Floor Systems
302.2.3.1.5
704—07 Identification of the Hazards of Materials for Emergency Response 502.8.4, 510.1, Table 1103.1
853—03 Installatin of Stationary Fuel Power Plants 924.1
SMACNA

Sheet Metal & Air Conditioning Contractors National Assoc., Inc.
4201 Lafayette Center Road
Chantilly, VA 20151-1209
 
Standard
reference
number
Title Referenced
in code
section number
* SMACNA 1966—05 HVAC Duct Construction Standards—Metal and Flexible 603.4, 603.9
* SMACNA 1884—03 Fibrous Glass Duct Construction Standards 603.5, 603.9
UL

Underwriters Laboratories, Inc.
333 Pfingsten Road
Northbrook, IL 60062-2096
 
Standard
reference
number
Title Referenced
in code
section number
17—94 Vent or Chimney Connector Dampers for Oil-fired Appliances—with Revisions through September 1998 803.6
103—01 Factory-built Chimneys, Residential Type and Building Heating Appliance—with Revisions
   through March 1999
805.2
127—99 Factory-built Fireplaces—with Revisions through November 1999 805.3, 903.1, 903.3
174—04 Household Electric Storage Tank Water Heaters—with Revisions through October 1999 1002.1
181—96 Factory-made Air Ducts and Air Connectors—with Revisions
   through December 1998
512.2, 603.5, 603.6.1, 603.6.2, 604.13
181A—98 Closure Systems for Use with Rigid Air Ducts and Air Connectors—with Revisions through
   December 1998
603.9
181B—95 Closure Systems for Use with Flexible Air Ducts and Air Connectors—with Revisions through
   December 1998
603.9
207—01 Refrigerant-containing Components and Accessories, Nonelectrical—with Revisions through
   October 1997
1101.2
268—96 Smoke Detectors for Fire Prevention Signaling Systems—with Revisions through January 1999 606.1
268A—98 Smoke Detectors for Duct Applications—with Revisions through September 2001 606.1
343—97 Pumps for Oil-Burning Appliances—with Revisions through May 2002 1302.7
391—95 Solid-fuel and Combination-fuel Central and Supplementary Furnaces—with Revisions through
   May 1999
918.1
412—04 Refrigeration Unit Coolers—with Revisions through November 1998 1101.2
471—95 Commercial Refrigerators and Freezers—with Revisions through April 1998 1101.2
508—99 Industrial Control Equipment 307.2.3
536—97 Flexible Metallic Hose—with Revisions through June 2003 1302.8
555—99 Fire Dampers—with Revisions through January 2002 607.3
555C—96 Ceiling Dampers 607.3, 607.6.2.1
555S—99 Smoke Dampers—with Revisions through April 2003 607.3, 607.3.1.1
586—96 High-efficiency, Particulate, Air Filter Units—with Revisions through August 2004 605.2
641—95 Type L Low-temperature Venting Systems—with Revisions through April 1999 802.1
647—93 Standard for Unvented Kerosene-Fired Room Heaters and Portable Heaters 922.2
710—95 Exhaust Hoods for Commercial Cooking Equipment—with Revisions through April 1999 507.1
710B—04 Recirculating Systems 507.1
726—98 Oil-fired Boiler Assemblies—with Revisions through January 2001 916.1, 1004.1
727—06 Oil-fired Centeral Furnaces—with Revisions through January 1999 918.1
729—03 Oil-fired Floor Furnaces—with Revisions through January 1999 910.1
730—03 Oil-fired Wall Furnaces—with Revisions through January 1999 909.1
731—08 Oil-fired Unit Heaters—with Revisions through May 2004 920.1
732—95 Oil-fired Storage Tank Water Heaters—with Revisions through January 1999 1002.1
737—96 Fireplace Stoves—with Revisions through January 2000 905.1
762—03 Outline of Investigation for Power Ventilators for Restaurant Exhaust Appliances 506.5.1
791—93 Residential Incinerators—with Revisions through May 1998 907.1
834—04 Heating, Water Supply and Power Boilers Electric—with Revisions through November 1998 1004.1
864—03 Standard for Control Units and Accessories for Fire Alarm
   Systems—with Revisions thru October 2003
513.12
867—00 Electrostatic Air Cleaners—with Revisions through May 2004 605.2
896—93 Oil-burning Stoves—with Revisions through May 2004 917.1, 922.1
900—94 Air Filter Units—with Revisions through October 1999 605.2
959—01 Medium Heat Appliance Factory-built Chimneys 805.5
1240—94 Electric Commercial Clothes Drying Equipment—with Revisions through May 2000 913.1
1261—01 Electric Water Heaters for Pools and Tubs—with Revisions through June 2004 916.1
1453—04 Electronic Booster and Commerical Storage Tank Water Heaters 1002.1
  UL—continued  
1479—03 Fire Tests of Through Penetrations Firestops 302.2.2.1.3, 302.2.3.1.1.2, 302.2.4
1482—98 Solid-fuel Type Room Heaters—with Revisions through January 2000 905.1
1777—04 Chimney Liners 801.16.1, 801.18.4
1820—97 Fire Test of Pneumatic Tubing for Flame and Smoke Characteristics—with Revisions through
   March 1999
602.2.1.3
1887—96 Fire Tests of Plastic Sprinkler Pipe for Visible Flame and Smoke Characteristics—with
   Revisions through June 1999
602.2.1.2
1978—95 Grease Ducts 506.3.2
1995—98 Heating and Cooling Equipment—with Revisions through August 1999 911.1, 918.1, 918.3, 1101.2
2043—96 Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories
   Installed in Air-handling Spaces—with Revisions through June 2001
602.2.1.4
2158—97 Outline of Investigation Electric Clothes Dryer—with Revisions through May 2004 913.1
2162—01 Outline of Investigation for Commercial Wood-fired Baking Ovens—Refractory Type 917.1
2221—01 Tests of Fire Resistive Grease Duct Enclosure Systems 506.3.10
 
Resources