Heads up: There are no amended sections in this chapter.
This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Chapter 1.

* Denotes standards that are incorporated by reference into 19 NYCRR Part 1224.

Margin markings have not been made in this chapter. The date of the reference standards denotes the new standards from 2007.

 

ANSI American National Standards Institute
25 West 43rd Street, Fourth Floor
New York, NY 10036
 
Standard
reference
number
Title  Referenced
 in code
section number
A13.1—07 Scheme for the Identification of Piping Systems  704.1.2.2
Z21.1—03 Household Cooking Gas Appliances—with Addenda Z21.1a-2003 and Z21.1b-2003  623.1
Z21.5.1—02 Gas Clothes Dryers—Volume I -Type 1 Clothes Dryers—with Addenda Z21.5.1a-2003  613.1
Z21.5.2—01 Gas Clothes Dryers—Volume II - Type 2 Clothes Dryers—with
   Addenda Z21.5.2a-2003 and Z21.5.2b-2003
 613.1, 614.3
* Z21.8—94 (R2002) Installation of Domestic Gas Conversion Burners  619.1
Z21.10.1—04 Gas Water Heaters—Volume I - Storage Water Heaters with Input Ratings of 75,000 Btu
  per Hour or Less—with Addenda Z21.10.1a-2002
 624.1
Z21.10.3—01 Gas Water Heaters—Volume III - Storage, Water Heaters with Input Ratings Above 75,000 Btu per hour,
  Circulating and Instantaneous—with Addenda Z21.10.3a-2003 and Z21.10.3b-2004
624.1
Z21.11.2—02 Gas-fired Room Heaters—Volume II - Unvented Room Heaters—with Addenda Z21.11.2a-2003 621.1
Z21.13—04 Gas-fired Low-Pressure Steam and Hot Water Boilers 631.1, 631.2
Z21.15—97 (R2003) Manually Operated Gas Valves for Appliances, Appliance Connector Valves, and
  Hose End Valves with Addenda Z21.15a-2001(R2003)
Table 409.1.1
Z21.19—02 Refrigerators Using Gas (R1999) Fuel 625.1
Z21.21—05 Automatic Valves for Gas Appliances  603.2
Z21.24—97 Connectors for Gas Appliances 411.1
Z21.40.1—96 (R2002) Gas-fired Heat Activated Air Conditioning and Heat Pump Appliances—with
  Addendum Z21.40.1a-1997 (R2002)
627.1
Z21.40.2—96 (R2002) Gas-fired Work Activated Air Conditioning and Heat Pump Appliances (Internal Combustion)—
  with Addendum Z21.40.2a-97 (R2002)
  627.1
Z21.42—93 (R2002) Gas-fired Illuminating Appliances  628.1
Z21.47—03 Gas-fired Central Furnaces 618.1
Z21.50—03 Vented Gas Fireplaces—with Addenda Z21.50a-2003  601.2, 604.1
Z21.56—01 Gas-fired Pool Heaters—with Addenda Z21.56a-2004 and Z21.56b-2004 617.1
Z21.58—95 (R2002) Outdoor Cooking Gas Appliances—with Addendum Z21.58a-1998 (R2002) and Z21.58b-2002 623.1
Z21.60—03 Decorative Gas Appliances for Installation in Solid-fuel Burning Fireplaces—with
  Addenda Z21.60a-2003
601.2, 602.1
Z21.61—83 (R1996) Toilets, Gas-Fired 626.1
Z21.69—02 Connectors for Movable Gas Appliances—with Addenda Z21.69a-2003 411.1, 411.1.1
Z21.75 Connectors for Outdoor Gas Appliances and Manufactured Homes 411.1, 411.2
Z21.80—03 Line Pressure Regulators 410.1
Z21.84—02 Manually-lighted, Natural Gas Decorative Gas Appliances for Installation in Solid
  Fuel Burning Fireplaces—with Addenda Z21.84a-2003
602.1, 602.2
Z21.86—04 Gas-fired Vented Space Heating Appliances   608.1, 609.1, 622.1
Z21.88—02 Vented Gas Fireplace Heaters—with Addenda Z21.88a-2003 and Z21.88b-2004  605.1
Z21.91—01 Ventless Firebox Enclosures for Gas-fired Unvented Decorative Room Heaters  621.7.1
Z83.4—03  Non-recirculating Direct-gas-fired Industrial Air Heaters  611.1
Z83.6—90 (R 1998) Gas-fired Infrared Heaters 630.1
Z83.8—02 Gas Unit Heaters and Gas-fired Duct Furnaces—with Addenda Z83.8a-2003  610.1, 620.1
Z83.11—02 Gas Food Service Equipment—with Addenda Z83.11a-2004  623.1
Z83.18—00 Recirculating Direct Gas-fired Industrial Air Heaters—
  with Addenda Z83.18a 2001 and Z83.18b-2003
612.1


ASME American Society of Mechanical Engineers
Three Park Avenue
New York, NY 10016-5990
 
Standard
reference
number
Title  Referenced
 in code
section number
A13.1—07 Scheme for Identification of Piping Systems Pipe Threads, General Purpose (inch) 704.1.2
B1.20.1—83 (Reaffirmed 2001) 403.9
B16.1—98 Cast Iron Pipe Flanges and Flanged Fittings, Class 25, 125 and 250 403.12
B16.20—98 Metallic Gaskets for Pipe Flanges Ring-joint, Spiral-wound, and Jacketed—
  with Addendum B16.20a-2000
403.12
B16.33—02 Manually Operated Metallic Gas Valves for Use in Gas Piping Systems up to 125 psig
(Sizes 1/2 through 2)
Table 409.1.1
B16.44—01 Manually Operated Metallic Gas Valves for Use in House Piping Systems Table 409.1.1
B31.3—02 Process Piping 704.1.2, 704.1.2.4, 705.2, 705.3
B36.10M—00 Welded and Seamless Wrought-steel Pipe 403.4.2
BPVC—04 ASME Boiler & Pressure Vessel Code (2001 Edition)
  (Section I, II, IV, V & IX)
631.1, 703.2.2, 703.3.3, 703.3.4
CSD-1—02 Controls and Safety Devices for Automatically Fired Boilers 631.1


ASTM ASTM International
100 Barr Harbor Drive
West Conshohocken, PA 19428-2959
 
Standard
reference
number
Title  Referenced
 in code
section number
A 53/A 53M—02 Specification for Pipe, Steel, Black and Hot Dipped Zinc-coated Welded and Seamless 403.4.2
A 106—04 Specification for Seamless Carbon Steel Pipe for High-temperature Service 403.4.2
A 254—97 (2002) Specification for Copper Brazed Steel Tubing  403.5.1
A 539—99 Specification for Electric Resistance-welded Coiled Steel Tubing for Gas and Fuel Oil Lines 403.5.1
B 88—03 Specification for Seamless Copper Water Tube 403.5.2
B 210—02 Specification for Aluminum and Aluminum-alloy Drawn Seamless Tubes 403.5.3
B 241/B 241M—02 Specification for Aluminum and Aluminum-alloy, Seamless Pipe and Seamless
  Extruded Tube
403.4.4, 403.5.3
B 280—03 Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service 403.5.2
C 64—72 (1977) Specification for Fireclay Brick Refractories for Heavy Duty Stationary Boiler Service 503.10.2.5
C 315—02 Specification for Clay Flue Linings 501.12
D 2513—04a Specification for Thermoplastic Gas Pressure Pipe, Tubing, and Fittings 403.6, 403.6.1, 403.11, 404.14.2
E 119—08a Standard Test Methods for Fire Tests of Building Construction and Materials 302.2.2.1, 302.2.3.1.1
E 814—02 Test Method of Fire Tests of Through-penetration Firestops 202, 302.2.2.1.2, 302.2.3.1.1.2


CGA Compressed Gas Association
1725 Jefferson Davis Highway, 5th Floor
Arlington, VA 22202-4102
 
Standard
reference
number
Title  Referenced
 in code
 section number
S-1.1—(2002) Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases 703.3
S-1.2—(1995) Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases  703.3
S-1.3—(1995) Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases  703.3


CSA CSA America Inc.
8501 E. Pleasant Valley Rd.
Cleveland, OH USA 44131-5575
 
Standard
reference
number
Title  Referenced
 in code
 section number
CSA America FC1—03 Stationary Fuel Cell Power Systems  633.1
CSA Requirement 3—88 Manually Operated Gas Valves for Use in House Piping Systems  Table 409.1.1
CSA 8—93 Requirements for Gas-fired Log Lighters for Wood Burning Fireplaces—with Revisions
  through January 1999
603.1
* LC 1—05 Fuel Gas Piping Systems Using Corrugated Stainless Steel Tubing (CSST) 403.5.4, 404.5.1


DOTn Department of Transportation
400 Seventh St. SW
Washington, DC 20590
 
Standard
reference
number
Title Referenced
 in code
  section number
49 CFR, Parts 192.281(e)& 192.283 (b) Transportation of Natural and Other Gas by Pipeline: Minimum Federal Safety Standards 403.6.1
49 CFR Parts 100—180 Hazardous Materials Regulations 703.2.2, 703.3.3, 703.3.4


ICC International Code Council
500 New Jersey Ave. NW, 6th Floor
Washington, DC 20001
 
Standard
reference
number
Title Referenced
in code
section number
BCNYS—10 Building Code of New York State® 302.2.2.2, 103.4, 104.2, 202, 301.10, 301.11, 301.12, 301.14, 302.1, 302.2.2.3, 302.2.3, 302.2.3.2.1.3, 302.2.3.2, 302.2.3.3, 305.6, 306.6, 401.1.1, 412.6, 413.3, 413.3.1, 413.9.2.4, 501.1, 501.3, 501.12, 501.15.4, 601.2, 609.3, 614.2, 635.1, 703.6
BCNYS—10 Electrical Provisions - Building Code of New York State®  306.3.1, 306.4.1, 306.5.1, 306.5.2, 309.2, 701.1, 703.6
EBCNYS—10 Existing Building Code of New York State® 101.2, 102.7
ECCCNYS—10 Energy Conservation Code of New York State® 301.2
FCNYS—10 Fire Code of New York State®  201.3, 401.2, 412.1, 412.6, 412.7, 412.7.3, 103.4, 102.7, 412.8, 413.1, 413.3, 413.3.1, 413.5, 413.9.2.5, 635.1, 701.1, 701.2, 703.2, 703.2.2, 703.3.8, 703.4, 703.5, 704.1.2, 704.3, 704.4, 706.2, 706.3, 707.1, 707.2, 708.1
MCNYS—10 Mechanical Code of New York State®  101.2.5, 201.3, 301.1.1, 301.13, 304.11, 307.1, 307.5, 501.1, 614.2, 618.5, 621.1, 624.1, 631.2, 632.1, 703.1.2, 706.3.2
PCNYS—10 Plumbing Code of New York State® 201.3, 301.6, 624.1.1, 624.2
PMCNYS—10 Property Maintenance Code of New York State® 102.7
RCNYS—10 Residential Code of New York State® 101.2, 601.22, 703.2.1


MSS Manufacturers Standardization Society of the Valve and Fittings Industry
127 Park Street, Northeast
Vienna, VA 22180
 
Standard
reference
number
Title Referenced
 in code
section number
SP-6—01 Standard Finishes for Contact Faces of Pipe Flanges and Connecting-end Flanges of Valves and Fittings 403.12
SP-58—02 Pipe Hangers and Supports—Materials, Design and Manufacture 407.2


NFPA National Fire Protection Association
1 Batterymarch Pike, P.O. Box 9101
Quincy, MA 02269-9101
 
Standard
reference
number
Title Referenced
 in code
section number
*30A—08 Code for Motor Fuel Dispensing Facilities and Repair Garages 305.4
*37—02 Installation and Use of Stationary Combustion Engines and Gas Turbines 616.1
*51—07 Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting, and Allied Processes  414.1
*58—08 Liquefied Petroleum Gas Code 401.2, 402.6.1, 403.6.2, 403.11
*70—08 National Electric Code 310.1, 310.2.1
82—04 Incinerators, Waste and Linen Handling Systems and Equipment  607.1
85—07 Boiler and Combustion Systems Hazards Code 631.1
*211—06 Chimneys, Fireplaces, Vents, and Solid Fuel-burning Appliances 503.5.2, 503.5.3, 503.5.6.1, 503.5.6.3
*288—01 Standard Methods of Fire Tests of Floor Fire Door Assemblies Installed
  Horizontally in Fire Resistance-Rated Floor Systems
302.2.3.1.5
*853—03 Standard for Installation of Stationary Fuel Cell Power Systems  633.1


UL Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062
 
Standard
reference
number
Title  Referenced
 in code
section number
103—01 Factory-built Chimneys, Residential Type and Building Heating Appliances—with Revisions through December 2003 506.1
127—99 Factory-built Fireplaces—with Revisions through November 1999 621.7
441—96 Gas Vents—with Revisions through December 1999 502.1
641—95 Type L Low-temperature Venting Systems—with Revisions through April 1999 502.1
651—05 Schedule 40 and Schedule 80 Rigid PVC Conduit and Fittings 403.6.3
795—99 Commercial-industrial Gas Heating Equipment  610.1, 618.1, 631.1
959—01 Medium Heat Appliance Factory-built Chimneys  506.3
*1479—03 Fire Tests of Through Penetration Firestops 302.2.2.1.2, 302.2.3.1.1.2, 302.2.4
1738—00 Venting Systems for Gas Burning Appliances, Categories II, III and IV—
  with Revisions through December 2000
502.1
1777—04 Standard for Chimney Liners 501.12, 501.15.4


 