ADOPTS WITH AMENDMENTS:

International Fire Code 2018 (IFC 2018)

Part I — Administrative

Part II — General Safety Provisions

Part III — Building and Equipment Design Features

Part IV — Special Occupancies and Operations

Part V — Hazardous Materials

Part VI — Referenced Standards

Part VII — Appendices

Heads up: There are no amended sections in this chapter.

User note:

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 102.9.

*Denotes standards that have been incorporated by reference into 19 NYCRR Part 1225.

AASHTO

American Association of State Highway and Transportation Officials
444 North Capitol Street, NW, Suite 249
Washington DC 20001

*HB-17—2002:

Specification for Highway Bridges, 17th Edition 2002

503.2.6

AFSI

Architectural Fabric Structures Institute
c/o Industrial Fabric Association International
1801 County Road B West
Roseville MN 55113

*FSAAS—1977:

Fabric Structures Associated Air Structures 2016

3103.10.2

ANSI

American National Standards Institute
25 West 43rd Street, 4th Floor
New York NY 10036

*ANSI E1.21—2013:

Entertainment Technology: Temporary Ground Supported Overhead Structures Used to Cover the Stage Areas and Support Equipment in the Production of Outdoor Entertainment Events

3105.1, 3105.4, 3105.5

ANSI Z21.69/CSA 6.16—09:

Connectors for Movable Gas Appliances

319.5, 607.4

API

American Petroleum Institute
1220 L Street, NW
Washington DC 20005

*Spec 12P—1995:

Specification for Fiberglass Reinforced Plastic Tanks

5704.2.13.1.5

*RP 651—3rd Edition (2007):

Cathodic Protection of Aboveground Petroleum Storage Tanks

5706.7, 5706.7.1

*Std 653—4th Edition (2009):

Tank Inspection, Repair, Alteration and Reconstruction

5706.7

RP 752—3rd Edition (2009):

Management of Hazards Associated with Location of Process Plant Buildings, CMA Managers Guide

5706.7

*RP 1604—3rd Edition (1996 R2010):

Closure of Underground Petroleum Storage Tanks

5704.2.13

RP 1615—(1996) 6th Edition (2011):

Installation of Underground-petroleum Storage Systems

5704.2.13.1.5, 5706.7

Std 2000—6th Edition (2009):

Venting Atmosphere and Low-pressure Storage Tanks: Nonrefrigerated and Refrigerated

5704.2.7.3.2

RP 2001—9th Edition (2012):

Fire Protection in Refineries, 8th Edition

5706.7

RP 2003—7th Edition (2008):

Protection Against Ignitions Arising out of Static, Lightning and Stray Currents

5706.7

*Publ 2009—7th Edition (2002):

Safe Welding and Cutting Practices in Refineries, Gas Plants and Petrochemical Plants

5706.7

*Std 2015—6th Edition 2001:

Safe Entry and Clearing of Petroleum Storage Tanks

5706.7, 5706.7.2

*RP 2023—3rd Edition (2001):

Guide for Safe Storage and Handling of Heated Petroleum-derived Asphalt Products and Crude-oil Residue

5706.7, 5706.7.3

*Publ 2028 3rd Edition—(2002):

Flame Arrestors in Piping Systems

5704.2.7.3.2

*Publ 2201 5th Edition—(2003):

Procedures for Welding or Hot Tapping on Equipment in Service

5706.7

RP 2350— 4th Edition (2012):

Overfill Protection for Storage Tanks in Petroleum Facilities, 3rd Edition

5704.2.7.5.8, 5706.4.6, 5706.7

ASCE/SEI

American Society of Civil Engineers
Structural Engineering Institute
1801 Alexander Bell Drive
Reston VA 20191-4400

*ASCE/SEI 24—14:

Flood Resistant Design and Construction

1203.1.8

ASHRAE

ASHRAE
1791 Tullie Circle NE
Atlanta GA 30329

*15—2016:

Safety Standard for Refrigeration Systems

605.1.1, 605.17.2

ASME

American Society of Mechanical Engineers
Two Park Avenue
New York NY 10016-5990

*A13.1—2007:

Scheme for the Identification of Piping Systems

3509.3, 5003.2.2.1, 5303.4.3, 5503.4.5, 5703.5.2

*ASME A17.1—2016/CSA B44—16:

Safety Code for Elevators and Escalators

508.1.6, 606.1, 907.3.3, 1009.4.1

*A17.3—2015:

Safety Code for Existing Elevators and Escalators

1103.3.1, 1103.3.2

B16.18—2012:

Cast Copper-Alloy Solder Joint Pressure Fittings

909.13.1

B16.22—2013:

Wrought Copper and Copper-alloy Solder-joint Pressure Fittings

909.13.1

B31.1—2016:

Power Piping

5003.2.2, Table 5703.6.2

B31.3—2016:

Process Piping

5003.2.2.2, Table 5703.6.2

B31.4—2015:

Pipeline Transportation Systems for Liquids and Slurries

Table 5703.6.2

*B31.9—2011:

Building Services Piping

Table 5703.6.2, 5703.6.3, 5703.6.11

BPVC—2015:

ASME Boiler and Pressure Vessel Code (Sections I, II, IV, V & VI, VIII)

5003.2.1, 5303.2, 5303.3.2, 5503.2.6, 5503.4.3, 5503.7, 5704.2.13.1.5, 5806.3.1, 5806.4.1, 5806.4.8

ASSE

American Society of Safety Engineers
520 N. Northwest Highway
Park Ridge IL 60068

*ANSI/ASSE Z359.1—2007:

Requirements for the ANSI/ASSE Z359 Fall Protection Code

1015.6, 1015.7

ASTM

ASTM International
100 Barr Harbor Drive, P.O. Box C700
West Conshohocken PA 19428-2959

B42—2015A:

Specification for Seamless Copper Pipe, Standard Sizes

909.13.1

B43—15:

Specification for Seamless Red Brass Pipe, Standard Sizes

909.13.1

B68/B58M—11:

Specification for Seamless Copper Tube, Bright Annealed (Metric)

909.13.1

B88—14:

Specification for Seamless Copper Water Tube

909.13.1

B251—10:

Specification for General Requirements for Wrought Seamless Copper and Copper-alloy Tube

909.13.1

B280—13:

Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

909.13.1

D56—05(2010):

Test Method for Flash Point by Tag Closed Cup Tester

202

D86—15:

Test Method for Distillation of Petroleum Products at Atmospheric Pressure

202

D92—12b:

Test Method for Flash and Fire Points by Cleveland Open Cup Tester

202, 2401.2, 5104.1.1, 5701.2

D93—15:

Test Method for Flash Point by Pensky-Martens Closed Up Tester

202

D323—2015A:

Test Method for Vapor Pressure of Petroleum Products (Reid Method)

202

D2859—16:

Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials

804.3.3.1, 804.3.3.2

D3278—96(2011):

Test Methods for Flash Point of Liquids by Small Scale Closed-cup Apparatus

202

E84—2016:

Standard Test Method for Surface Burning Characteristics of Building Materials

202, 803.1, 803.1.2, 803.3, 803.5.2, 803.10, 803.12, 803.13, 804.1.1, 804.1.2, 804.2.4

E108—2016:

Standard Test Methods for Fire Tests of Roof Coverings

317.2, 317.3

E648—15e1:

Standard Test Method for Critical Radiant Flux of Floor-covering Systems Using a Radiant Heat Energy Source

804.3.1, 804.3.2, 804.4

E681—09(2015):

Test Method for Concentration Limits of Flammability of Chemicals (Vapors and Gases)

202

E1354—2016:

Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter

304.3.2, 304.3.4, 318.1, 808.1, 808.2, 2310.5.3, 3304.2.3, 3603.4

E1529—14a:

Standard Test Method for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies

5704.2.9.2.3

E1537—2015:

Test Method for Fire Testing of Upholstered Furniture

805.1.1.2, 805.2.1.2, 805.3.1.2, 805.4.1.2

E1590—13:

Test Method for Fire Testing of Mattresses

805.1.2.2, 805.2.2.2, 805.3.2.2.1, 805.4.2.2

E1966—2015:

Standard Test Method for Fire-resistant Joint Systems

202

E2072—14:

Standard Specification for Photoluminescent (Phosphorescent) Safety Markings

1025.4

E2404—15a:

Standard Practice for Specimen Preparation and Mounting of Textile, Paper or Polymeric (Including Vinyl) and Wood Wall or Ceiling Coverings, Facing and Veneers to Assess Surface Burning Characteristics:

803.5.1, 803.5.2, 803.12

E2573—12:

Standard Practice for Specimen Preparation and Mounting of Site-fabricated Stretch Systems to Assess Surface Burning Characteristics

803.10

E2579—13:

Standard Practice for Specimen Preparation and Mounting of Wood Products to Assess Surface Burning Characteristics

803.13

F1085—14:

Standard Specification for Mattress and Box Springs for Use in Berths in Marine Vessels

805.3.2.2.2

F2006—17:

Standard/Safety Specification for Window Fall Prevention Devices for Non-emergency Escape (Egress) and Rescue (Ingress) Windows

1015.8

F2090—17:

Specification for Window Fall Prevention Devices with Emergency Escape (Egress) Release Mechanisms

1015.8, 1015.8.1, 1030.1.1

F2200—14:

Standard Specification for Automated Vehicular Gate Construction

503.5, 503.6

BHMA

Builders Hardware Manufacturers' Association
355 Lexington Avenue, 15th Floor
New York NY 10017

*A156.10—2011:

American National Standard for Power-operated Pedestrian Doors

1010.1.4.2

*A156.19—2013:

American National Standard for Power Assist and Low-energy Power-operated Doors

1010.1.4.2

*A156.27—2011:

Power- and Manual-operated Revolving Pedestrian Doors

1010.1.4.1, 1010.1.4.1.1

A156.38—2014:

Low-energy Power-operated Sliding and Folding Doors

1010.1.4.2

CA

State of California Department of Consumer Affairs
Bureau of Electronics and Appliance Repair, Home Furnishings and Thermal Insulation
4244 South Market Court, Suite D
Sacramento CA 95834-1243

California Technical Bulletin 129—1992:

Flammability Test Procedure for Mattresses for Use in Public Buildings

805.1.2.2, 805.2.2.2, 805.3.2.2.1, 805.4.2.2

California Technical Bulletin 133—1991:

Flammability Test Procedure for Seating Furniture for Use in Public Occupancies

805.1.1.2, 805.2.1.2, 805.4.1.2

CGA

Compressed Gas Association
14501 George Carter Way, Suite 103
Chantilly VA 20151

C-7—(2014):

Guide to Classification and Labeling of Compressed Gases

5303.4.2, 5503.4.2

ANSI/CGA G-13—(2015):

Storage and Handling of Silane and Silane Mixtures (an American National Standard)

6404.1, 6404.2, 6405.3

P-1—(2015):

Standard for Safe Handling of Compressed Gases in Containers

5305.7

ANSI/CGA P-18—(2013):

Standard for Bulk Inert Gas Systems

5501.1

S-1.1—(2017):

Pressure Relief Device Standards—Part 1—Cylinders for Compressed Gases

5303.3.2, 5503.2

S-1.2—(2009):

Pressure Relief Device Standards—Part 2—Cargo and Portable Tanks for Compressed Gases

5303.3.2, 5503.2

S-1.3—(2016):

Pressure Relief Device Standards—Part 3—Stationary Storage Containers for Compressed Gases

5303.3.2, 5503.2

V-1—(2013):

Standard for Gas Cylinder Valve Outlet and Inlet Connections

3505.2.1

CGR

Coast Guard Regulations
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325

*46 CFR Parts 30, 32, 35 & 39—1999:

Shipping

5706.8

CPSC

Consumer Product Safety Commission
4330 East-West Highway
Bethesda MD 20814

16 CFR Part 1500—2009:

Hazardous Substances and Articles; Administration and Enforcement Regulations

202, 5601.1.3

16 CFR Part 1500.41—2009:

Method for Testing Primary Irritant Substances

202

16 CFR Part 1500.42—2009:

Test for Eye Irritants

202

16 CFR Part 1500.44—2009:

Method for Testing Extremely Flammable and Flammable Solids

202

16 CFR Part 1507—2002:

Fireworks Devices

202, 5601.1.3

16 CFR Part 1630—2007:

Standard for the Surface Flammability of Carpets and Rugs

804.3.3.1, 804.3.3.2

DOC

U.S. Department of Commerce
1401 Constitution Avenue, NW
Washington DC 20230

16 CFR Part 1632—2015:

Standard for the Flammability of Mattress and Mattress Pads (FF 4-72, Amended)

805.1.2.1, 805.2.2.1, 805.3.2.1, 805.4.2.1

DOL

U.S. Department of Labor
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325

29 CFR Part 1910.1000—2015:

Air Contaminants

202, 2104.2.1

29 CFR Part 1910.1200—2015:

Hazard Communication

202, 5603.6

DOTn

U.S. Department of Transportation
Office of Hazardous Material Safety
1200 New Jersey Avenue SE East Building 2nd Floor Washington DC 20590

33 CFR Part 154—2015:

Facilities Transferring Oil or Hazardous Material in Bulk

5706.8

33 CFR Part 155—2015:

Oil or Hazardous Material Pollution Prevention Regulations for Vessels

5706.8

33 CFR Part 156 —2015:

Oil and Hazardous Material Transfer Operations

5706.8

49 CFR Parts 100-185—2015:

Hazardous Materials Regulations

202, 3505.4, 5303.2, 5503.4.3, 5503.7, 5601.1, 5601.1.3, 5601.3, 5706.5.1.15

49 CFR Part 172—2015:

Hazardous Materials Tables, Special Provisions, Hazardous Materials Communications, Emergency Response Information and Training Requirements

5604.6.5.2

*49 CFR Part 173—2009:

Shippers—General Requirements for Shipments and Packagings

5104.1.1, 5606.3

*49 CFR Part 173.137—2009:

Shippers—General Requirements for Shipments and Packagings: Class 8—Assignment of Packing Group

202

DOTy

U.S. Department of Treasury
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325

27 CFR Part 555—2015:

Commerce in Explosives, as amended through April 1, 1998

202, 5604.6.5.2

EN

European Committee for Standardization (EN)
Central Secretariat
Rue de Stassart 36
Brussels B-10 50

European Standard EN 1081—1998:

Resilient Floor Coverings—Determination of the Electrical Resistance

2309.5.1.1

FCC

Federal Communications Commission
Wireless Telecommunications Bureau (WTB)
445 12th Street SW
Washington DC 20554

47 CFR Part 90.219—2014:

Private Land Mobile Radio Services—Use of Signal Boosters

510.5.4

FM

FM Approvals
Headquarters Office
1151 Boston-Providence Turnpike
P.O. Box 9102
Norwood MA 02062

4430—12:

Approval Standard for Heat and Smoke Vents

910.3.1

ANSI/FM 4996—15:

Approval Standard for Classification of Pallets and Other Material Handling Products as Equivalent to Wood Pallets

315.7.5, 3206.4.1.1

ICC

International Code Council, Inc.
500 New Jersey Avenue, NW
6th Floor
Washington DC 20001

*BCNYS—20:

Building Code of New York State

102.4, 201.3, 202, 304.1.3, 306.1, 311.3, 313.1, 317.1, 403.8.3.2, 403.11.4, 404.2.1, 504.1, 508.1, 508.1.2, 603.2, 603.3.2.5, 603.6.1, 603.8, 606.3, 606.4, 606.5, 606.6, 701.1, 801.1, 803.1, Table 803.3, 803.11.1, 803.11.2, 803.15, 807.2, 807.5.1.2, 808.1, 808.2, 901.4.1, 901.4.2, 901.4.3, 903.2, 903.2.5.2, 903.2.9.1, 903.2.10, 903.3.1.1.1, 903.3.1.2, 903.3.1.2.1, 903.3.1.2.3, 903.3.2, 904.13, 907.1.1, 907.2.1, 907.2.6.2, 907.2.6.3.3, 907.2.7, 907.2.12, 907.2.17, 907.2.20, 907.5.2.1, 907.6.6, 909.1, 909.2, 909.3, 909.4.3, 909.5, 909.5.3, 909.5.3.1, 909.5.3.2, 909.6.3, 909.10.5, 909.11.1, 909.18.8, 909.21.1, 910.4.5, Table 911.1, 911.2, 913.2.1, 914.1, 914.2.1, 914.3.1, 914.3.2, 914.4.1, 914.5.3, Table 914.8.3, 914.8.3.2, 914.10, 1003.2, 1003.5, Table 1004.5, 1004.6, 1005.7.2, 1006.2.1, Table 1006.2.1, 1008.3.4, 1009.2, 1009.4.1, 1009.4.2, 1009.5, 1009.6.4, 1009.7.2, 1010.1.4.1, 1010.1.4.3, 1010.1.5, 1010.1.7, 1010.1.9.1, 1010.1.9.12, 1011.10, 1011.11, 1011.12.2, 1012.6.3, 1012.6.4, 1014.1, 1015.2, 1015.2.1, 1016.2, Table 1017.2, 1018.3, 1018.5, 1019.3, 1019.4, 1020.1, Table 1020.1, 1020.1.1, 1021.4, 1023.2, 1023.3.1, 1023.4, 1023.5, 1023.6, 1023.7, 1023.11, 1023.11.1, 1023.11.2, 1024.3, 1024.5, 1024.6, 1024.7, 1026.2, 1026.3, 1026.4.1, 1027.5, 1028.1, 1029.1.1.1, 1029.14.1, 1029.16.4, 1103.3.2, 1103.4.1, 1103.4.8, 1103.4.9.1, 1103.4.9.2.1, 1103.4.9.2.2, 1103.4.9.4, 1103.4.9.5, 1103.4.10, 1104.5, 1104.17, 1104.17.1, 1104.18, Table 1104.18, 1105.4.1, 1105.4.3.1, 1105.4.3.2, 1105.5.7, 1105.7.2, 1105.7.3, 1105.7.4, 1105.7.5, 1105.7.6, 1105.8, 1203.1, 1203.1.3, 1203.1.8, 1203.2.1, 1203.2.7, 1203.2.8, 1203.2.10, 1203.2.15, 1203.2.18, 1204.1, 1205.6.2, 2004.6, 2006.17, 2007.1, 2007.4, 2103.3, 2107.1, 2301.1, 2301.4, 2303.1, 2307.4, 2308.3, 2308.3.1, 2309.3.1.5.1, 2309.3.2, 2310.1, 2311.1, 2311.3.1, 2311.4.1, 2311.8.3, 2404.2, 2404.3.1, 2404.3.3.6, 2404.3.4, 2405.2, 2701.1, 2701.4, 2703.2.2, 2703.3.1, 2703.3.2, 2703.3.3, 2703.3.4, 2703.3.8, 2703.14, 2703.14.1, 2703.14.2, 2703.15.1, 2704.3.1, 2705.2.3.2, 2705.3.1, 2705.3.2.1, 2705.3.3, 2803.1, 2905.1, 2909.2, 2909.4, 2909.6, 3101.1, 3103.1, 3103.3.1, 3103.8.2, 3103.8.4, 3103.9.1, 3103.9.2, 3103.9.3, 3104.1, 3105.5, 3201.3, 3206.3.2, 3206.9, 3207.2, 3208.2, 3314.1, 3403.1, 3704.3, 3704.4, 3704.5, 3801.1, 3801.2, 3804.1, 3804.1.1.1, Table 3805.4, Table 3806.2.1, 3901.1, 3903.1, 3904.1, 5003.2.2.2, 5003.2.8, 5003.8.1, Table 5003.8.2, 5003.8.3, 5003.8.3.1, 5003.8.4.1, 5003.9.9, 5004.13, 5005.2, 5005.3.9, 5101.1, 5303.16.1, 5303.16.2, 5306.1, 5306.2, 5306.2.1, 5306.2.2, 5307.4.6, 5503.1.2, 5503.5.2, 5504.2.1.2, 5504.2.2.2, 5505.4.1, 5604.2, Table 5604.5.2(3), 5605.5, 5701.3, 5704.2.7.7, 5704.2.8.1, 5704.2.8.2, 5704.2.9.3, 5704.2.9.4, 5704.3.3.5, 5704.3.7.1, 5704.3.8, 5705.3.4, 5705.3.5.3, 5705.3.7.1, 5705.3.7.2, 5705.3.7.3, 5705.3.7.4, 5705.3.7.5.1, 5706.2.3, 5706.4.1, 5803.1.1, 5806.4.3, 5808.1, 5808.3, 5808.3.2, 5906.2.2, 5906.2.3, 5906.4.2, 6003.1.4.2, 6005.3.1, 6109.11.2, 6204.1.2, 6306.4, 6404.1.4, 6604.1

*EBCNYS—20:

Existing Building Code of New York State

102.3, 1011.5.2, 1103.1, 1104.18, 1105.5.2

*PCNYS—20:

Plumbing Code of New York State

201.3, 903.3.5, 904.11.1.3, 912.6, 2311.2.3, 5004.2.2.6

*RCNYS—20:

Residential Code of New York State

102.5, 202, 1001.1, 1204.1, 1204.2.1

IWUIC—18:

International Wildland-Urban Interface Code®

304.1.2

IIAR

International Institute of Ammonia Refrigeration
1001 N. Fairfax Street, Suite 503
Alexandria VA 22314

ANSI/IIAR-2—2014:

Safe Design of Closed-circuit Ammonia Refrigerating Systems

605.1.2, 605.8

ANSI/IIAR-7—2013:

Developing Operating Procedures for Closed-circuit Ammonia Mechanical Refrigerating Systems

605.1.2

ANSI/IIAR-8—2015:

Decommissioning of Closed-circuit Ammonia Refrigerating Systems

605.1.2

IKECA

International Kitchen Exhaust Cleaning Association
100 North 20th Street, Suite 400
Philadelphia PA 19103

C10—2016:

IKECA C10, Standard for the Methodology for Cleaning of Commercial Kitchen Exhaust Systems

607.3.3.2

ISO

International Organization for Standardization (ISO)
ISO Central Secretariat
1 ch, de la Voie-Creuse, Case postale 56
CH-1211 Geneva 20 Switzerland

ISO 8115—86:

Cotton Bales—Dimensions and Density

Table 2704.2.2.1, Table 5003.1.1(1)

NEMA

National Electrical Manufacturer's Association
1300 North 17th Street
Suite 900
Rosslyn VA 22209

250—2014:

Enclosures for Electrical Equipment (1,000 Volt Maximum)

6005.2

NFPA

National Fire Protection Association
1 Batterymarch Park
Quincy MA 02169-7471

*02—16:

Hydrogen Technologies Code

1205.3, 1205.4, 2309.3.1.1, 2309.3.1.2, 2309.6, 2311.8, 2311.8.2, 2311.8.10, 2311.8.11, 5301.1, 5801.1

*04—15:

Standard for Integrated Fire Protection and Life Safety System Testing

901.6.2.1, 901.6.2.2

*10—18:

Standard for Portable Fire Extinguishers

Table 901.6.1, 906.2, Table 906.3(1), Table 906.3(2), 906.3.2, 906.3.4, 3006.3

*11—16:

Standard for Low-, Medium-, and High-expansion Foam

904.7, 5704.2.9.2.2

*12A—15:

Standard on Halon 1301 Fire Extinguishing Systems

Table 901.6.1, 904.9

*13D—16:

Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes

903.3.1.3

*13R—16:

Standard for the Installation of Sprinkler Systems in Low-rise Residential Occupancies

903.3.1.2, 903.3.5.2, 903.4

*14—16:

Standard for the Installation of Standpipe and Hose Systems

905.2, 905.3.4, 905.4.2, 905.6.2, 905.8

*15—17:

Standard for Water Spray Fixed Systems for Fire Protection

5704.2.9.2.3

*16—15:

Standard for the Installation of Foam-water Sprinkler and Foam-water Spray Systems

904.7, 904.12

*17—17:

Standard for Dry Chemical Extinguishing Systems

Table 901.6.1, 904.6, 904.12

*17A—17:

Standard for Wet Chemical Extinguishing Systems

Table 901.6.1, 904.5, 904.12

*20—16:

Standard for the Installation of Stationary Pumps for Fire Protection

913.1, 913.2, 913.5.1

*22—18:

Standard for Water Tanks for Private Fire Protection

507.2.2

*24—16:

Standard for Installation of Private Fire Service Mains and Their Appurtenances

507.2.1, 2809.5

*25—17:

Standard for the Inspection, Testing and Maintenance of Water-based Fire Protection Systems

507.5.3, Table 901.6.1, 904.7.1, 912.7, 913.5

*30A—18:

Code for Motor Fuel-dispensing Facilities and Repair Garages

2301.4, 2301.5, 2301.6, 2306.6.3, 2310.1

*31—16:

Standard for the Installation of Oil-burning Equipment

603.1.7, 603.3.1, 603.3.3

*32—16:

Standard for Dry Cleaning Plants

2107.1, 2107.3

*33—15:

Standard for Spray Application Using Flammable or Combustible Materials

2403.3

*34—15:

Standard for Dipping, Coating and Printing Processes Using Flammable or Combustible Liquids

2405.3, 2405.4.1.1

*35—16:

Standard for the Manufacture of Organic Coatings

2901.3, 2905.4

*40—16:

Standard for the Storage and Handling of Cellulose Nitrate Film

306.2

*45—15:

Standard on Fire Protection for Laboratories Using Chemicals (2015 Edition)

3803.1.5, 3804.1.1.7, 3805.2.1, 3805.2.2

*51—18:

Standard for the Design and Installation of Oxygen-fuel Gas Systems for Welding, Cutting and Allied Processes

3501.5, 3507.1, 3509.1

*52—16:

Vehicular Gaseous Fuel System Code

319.9.2, 5301.1

*55—16:

Compressed Gases and Cryogenic Fluids Code

3508.1, 5301.1, 5307.4.2, 5501.1, 5801.1, 6301.1

*56—17:

Standard for Fire and Explosion Prevention during Cleaning and Purging of Flammable Gas Piping Systems

3306.2.1

*59A—16:

Standard for the Production, Storage and Handling of Liquefied Natural Gas (LNG)

5301.1, 5501.1

*61—17:

Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities

Table 2204.1

*69—14:

Standard on Explosion Prevention Systems

911.1, 911.3, Table 2204.1

*80—16:

Standard for Fire Doors and Other Opening Protectives

705.2, 706.1, 1010.1.4.3, 1031.2.2

*85—15:

Boiler and Combustion System Hazards Code

Table 2204.1

*86—15:

Standard for Ovens and Furnaces

3001.1

*92—15:

Standard for Smoke Control Systems

909.7, 909.8

*96—17:

Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations

607.2, 904.12

*101—18:

Life Safety Code®

1029.6.2

*105—16:

Standard for Smoke Door Assemblies and Other Opening Protectives

705.2, 706.1

*110—16:

Standard for Emergency and Standby Power Systems

913.5.2, 913.5.3, 1203.1.3, 1203.4, 1203.5

*111—13:

Standard on Stored Electrical Energy Emergency and Standby Power Systems

1203.1.3, 1203.4, 1203.5

*120—15:

Standard for Fire Prevention and Control in Coal Mines

Table 2204.1

*160—16:

Standard for the Use of Flame Effects Before an Audience

308.3.2

*170—18:

Standard for Fire Safety and Emergency Symbols

1025.2.6.1

*204—15:

Standard for Smoke and Heat Venting

Table 901.6.1, 910.5.1, 910.5.2

*211—16:

Standard for Chimneys, Fireplaces, Vents and Solid Fuel-burning Appliances

603.2

*241—13:

Standard for Safeguarding Construction, Alteration and Demolition Operations

3301.1, 3308.2

*253—15:

Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source

804.3.1, 804.3.2, 804.4

*260—13:

Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture

805.1.1.1, 805.2.1.1, 805.3.1.1, 805.4.1.1

*261—18:

Standard Method of Test for Determining Resistance of Mock-up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes

805.2.1.1, 805.3.1.1, 805.4.1.1, 805.1.1.1

*265—15:

Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings in Full Height Panels and Walls

803.5.1, 803.5.1.1

*286—15:

Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

803.1, 803.1.1, 803.1.1.1, 803.3, 803.12, 803.13, 804.1.1, 804.2.4

*289—13:

Standard Method of Fire Test for Individual Fuel Packages

807.3, 807.4.1, 807.5.1.1, 808.3

*303—16:

Fire Protection Standard for Marinas and Boatyards

3603.5, 3603.6, 3604.2

*318—18:

Standard for the Protection of Semiconductor Fabrication Facilities

2703.16

*326—15:

Standard for the Safeguarding of Tanks and Containers for Entry, Cleaning or Repair

3510.1

*385—17:

Standard for Tank Vehicles for Flammable and Combustible Liquids

5706.5.4.5, 5706.6, 5706.6.1

*407—17:

Standard for Aircraft Fuel Servicing

2006.2, 2006.3

*409—16:

Standard for Aircraft Hangars

914.8.3, Table 914.8.3, 914.8.3.1, 914.8.6

*410—15:

Standard on Aircraft Maintenance

2004.7

*484—15:

Standard for Combustible Metals

Table 2204.1

*498—18:

Standard for Safe Havens and Interchange Lots for Vehicles Transporting Explosives

5601.1.2

*505—18:

Fire Safety Standard for Powered Industrial Trucks, Including Type Designations, Areas of Use, Maintenance and Operation

309.2

*652—16:

The Fundamentals of Combustible Dust

2201.1, 2203.1, 2203.2

*654—17:

Standard for Prevention of Fire and Dust Explosions from the Manufacturing, Processing and Handling of Combustible Particulate Solids

Table 2204.1

*655—17:

Standard for the Prevention of Sulfur Fires and Explosions

Table 2204.1

*664—17:

Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities

Table 2204.1, 2805.3

*701—15:

Standard Methods of Fire Tests for Flame-propagation of Textiles and Films

807.3, 807.4.1, 807.5.1.2, 2603.5, 3104.2

*703—18:

Standard for Fire Retardant-Wood and Fire-Retardant Coatings for Building Materials

803.4

*704—17:

Standard System for Identification of the Hazards of Materials for Emergency Response

202, 605.7, 5003.2.2.2, 5003.5, 5003.10.2, 5005.1.10, 5005.1.12, 5005.2.1.1, 5005.4.4, 5503.4.1, 5704.2.3.2

*720—15:

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

915.5.1, 915.5.2, 915.6

*750—15:

Standard on Water Mist Fire Protection Systems

202, Table 901.6.1, 904.11.1.1, 904.12

*853—15:

Installation of Stationary Fuel Cell Power Systems

1205.3, 1205.4, 1205.6.2, 1205.11, 1205.12

*914—15:

Code for Fire Protection of Historic Structures

*1122—18:

Code for Model Rocketry

5601.1.4

*1124—06:

Code for the Manufacture, Transportation, Storage and Retail Sales of Fireworks and Pyrotechnic Articles

202, 5601.1.3, 5604.2, 5605.1, 5605.3, 5605.4, 5605.5, 5609.1

*1125—17:

Code for the Manufacture of Model Rocket and High Power Rocket Motors

5601.1.4

*1126—16:

Standard for the Use of Pyrotechnics Before a Proximate Audience

5604.2, 5605.1, 5608.1, 5608.2.2, 5608.4, 5608.5

*1127—18:

Code for High Power Rocketry

5601.1.4

*1142—17:

Standard on Water Supplies for Suburban and Rural Fire Fighting

507.2

*1221—16:

Standard for the Installation, Maintenance and Use of Emergency Services Communications Systems

510.4.2, 510.5

*1402—19:

Guide to Building Fire Service Training Centers

320.1

*1403—18:

Standard on Live Fire Training Evolutions

320.1

*2001—15:

Standard on Clean Agent Fire Extinguishing Systems

Table 901.6.1, 904.10

*2010—15:

Standard for Fixed Aerosol Fire-extinguishing Systems

Table 901.6.1, 904.14

UL

Underwriters Laboratories LLC
333 Pfingsten Road
Northbrook IL 60062

10C—09:

Positive Pressure Fire Tests of Door Assemblies—with revisions through February 2015

1010.1.10.1

30—95:

Metal Safety Cans—with revisions through June 2014

5003.9.10, 5005.1.10, 5705.2.4

58—96:

Steel Underground Tanks for Flammable and Combustible Liquids—with revisions through July 1998

5704.2.13.1.5

80—07:

Steel Tanks for Oil-burner Fuels and Other Combustible Liquids—with revisions through January 2014

319.7.1, 603.3.2.1, 608.2

87A—15:

Outline of Investigation for Power-operated Dispensing Devices for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent

2306.8.1

142—06:

Steel Aboveground Tanks for Flammable and Combustible Liquids—with revisions through August 2014

319.7.1, 603.3.2.1, 608.2, 2306.2.3

199E—04:

Outline of Investigation for Fire Testing of Sprinklers and Water Spray Nozzles for Protection of Deep Fat Fryers

904.12.4.1

217—06:

Single and Multiple Station Smoke Alarms—with revisions through October 2015

907.2.10

294—1999:

Access Control System Units—with revisions through February 2015

1010.1.9.7, 1010.1.9.8.1, 1010.1.9.9, 1010.1.9.10

300—05(R2010):

Fire Testing of Fire Extinguishing Systems for Protection of Commercial Cooking Equipment—with revisions through December 2014

904.12

300A—06:

Outline of Investigation for Extinguishing System Units for Residential Range Top Cooking Surfaces

904.13.1.1

305—2012:

Panic Hardware—with revisions through August 2014

1010.1.10.1

325—02:

Door, Drapery, Gate, Louver and Window Operators and Systems—with revisions through May 2015

503.5, 503.6

499—05:

Standard for Electrical Heating Appliances—with revisions through November 2014

608.6

647—93:

Standard for Unvented Kerosene-fired Room Heaters and Portable Heaters—with revisions through April 2010

603.4

710—2012:

Exhaust Hoods for Commercial Cooking Equipment—with revisions through November 2013

607.2

710B—2011:

Recirculating Systems—with revisions through August 2014

607.2, 904.12

723—08:

Standard for Test for Surface Burning Characteristics of Building Materials—with revisions through August 2013

202, 803.1, 803.1.2, 803.3, 803.5.2, 803.10, 803.12, 803.13, 804.1.1, 804.1.2, 804.2.4

790—04:

Standard Test Methods for Fire Tests of Roof Coverings—with revisions through July 2014

317.2, 317.3

793—08:

Automatically Operated Roof Vents for Smoke and Heat—with revisions through September 2011

910.3.1

817—2015:

Standard for Cord Sets and Power-supply Cords—with revisions through March 2015

604.5

864—03:

Control Units and Accessories for Fire Alarm Systems—with revisions through December 2014

909.12, 3905.1.2

900—04:

Air Filter Units—with revisions through April 2015

2404.7.8

924—06:

Standard for Safety Emergency Lighting and Power Equipment—with revisions through April 2014

1013.5, 3103.12.6.1

1037—99:

Antitheft Alarms and Devices—with revisions through December 2009

506.1

1046—2010:

Grease Filters for Exhaust Ducts—with revisions through January 2012

607.3.1

1275—05:

Flammable Liquid Storage Cabinets—with revisions through November 2014

5003.8.7.1, 5704.3.2.1.1

1313—93:

Standard for Nonmetallic Safety Cans for Petroleum Products—with revisions through November 2012

5003.9.10

1315—95:

Standard for Safety for Metal Waste Paper Containers—with revisions through September 2012

808.1, 808.2

1316—94:

Glass Fiber Reinforced Plastic Underground Storage Tanks for Petroleum Products, Alcohols and Alcohol-gasoline Mixtures—with revisions through May 2006

5704.2.13.1.5

1363—07:

Relocatable Power Taps—with revisions through September 2015

604.4.1

1564—2015:

Industrial Battery Chargers

1741—2015:

Inverters, Converters, Controllers and Interconnection System Equipment for Use with Distributed Energy Resources

1805—2002:

Standard for Laboratory Hoods and Cabinets

3805.2.2

1973—13:

Standard for Batteries for Use in Light Electric Rail (LER) Applications and Stationary Applications.

1975—06:

Fire Tests for Foamed Plastics Used for Decorative Purpose

807.5.1.1, 808.3

1994—04:

Standard for Luminous Egress Path Marking Systems—with revisions through May 2015

1008.2.1, 1025.2.1, 1025.2.3, 1025.2.4, 1025.2.5, 1025.4

2017—08:

General-purpose Signaling Devices and Systems—with revisions through May 2011

3905.1.2

2034—08:

Single and Multiple Station Carbon Monoxide Alarms—with revisions through March 2015

915.4.2

2075—2013:

Standard for Gas and Vapor Detectors and Sensors

915.5.1, 915.5.3, 3905.1.2

2079—04:

Tests for Fire Resistance of Building Joint Systems—with revisions through August 2015

202

2085—97:

Protected Above-ground Tanks for Flammable and Combustible Liquids—with revisions through September 2010

202, 603.3.2.1, 2306.2.2, 2306.2.3, 5704.2.7.4, 5704.2.9.2.3, 5704.2.9.7.4, 5705.3.8.2

2152—15:

Outline of Investigation for Special Purpose Nonmetallic Containers and Tanks for Specific Combustible or Noncombustible Liquids

608.3

2196—2001:

Tests for Fire Resistive Cables—with revisions through March 2012

913.2.2, 1203.3

2200—2012:

Stationary Engine Generator Assemblies—with revisions through July 2015

1203.1.1

2208—2010:

Solvent Distillation Units—with revisions through September 2015

5705.4.1

2245—06:

Below-grade Vaults for Flammable Liquid Storage Tanks

5704.2.8.1

2335—10:

Fire Tests of Storage Pallets—with revisions through September 2012

315.7.5, 3206.4.1.1

2360—00:

Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semi-Conductor Tool Construction— with revisions through May 2013

2703.10.1.2

9540—14:

Outline of Investigation for Energy Storage Systems and Equipment

USC

United States Code
c/o Superintendent of Documents
U.S. Government Printing Office
Washington DC 20402-9325

18 USC Part 1, Chapter 40:

Importation, Manufacture, Distribution and Storage of Explosive Materials

202

21 USC Chapter 9:

United States Food, Drug and Cosmetic Act

202

UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING